Technical rider Update : October 2016

Size: px
Start display at page:

Download "Technical rider Update : October 2016"

Transcription

1 Technical rider Update : October 2016 Théâtre de Beaulieu Phone : Av. des Bergières Lausanne Manager : Florence Mury-Favrod Tél : florence.favrod@theatredebeaulieu.ch Tech manager: Zinzoline sàrl Antoine Marchon Stéphane Gattoni Christian Yerly Tél : technique@theatredebeaulieu.ch

2 DESCRIPTION AND DIMENSIONS Front stage with proscenium, rake 3,6 % - plans on request Maximum arch opening 14 m Depth m (17 m with orchestra pit up) Stage height 1.30 m Width wall to wall 22 m + one recess stage right 4 x 2.5 m Width between lateral catwalk 19.5 m Arch height 6.85 m Height below grid 16 m Max height below pipes 15.5 m Backstage extension opening 11.5 m x depth 6 m x height 6 m Stage load capacity 500 kg per m2. Can be reinforced and propped from the first understage Stage access from stage left and stage right. Stage curtains Red traveler stage curtain, Clivia 600. Electric opening from stage right, variable speed. Up and down on counterbalanced pipe n 2. Black Up and down curtain, on counterbalanced pipe n 1 Rigging 25 counterbalanced pipes, maximum load capacity 350kg 2 electric pipes on the sides, maximum load capacity 350kg 7 trusses with hoists, max. load 500kg 1 truss at proscenium, max. load 500kg 1 FOH truss, max. load 500kg 6 hoists 250kg D8+ 5 hoists 500kg D8+ Scenery access 1 exterior elevating platform directly backstage. Door size : Width 2.23 m, height 2.80 m. Max. load 1,2 t. 1 street level service lift from Ch. du Presbytère. Size : 2.7m x 1.5 m, height m., max. load 1,5 t. p. 2 / 13

3 Orchestra pit 2 available positions: Proscenium only lowered to level of first understage with a capacity of 50 musicians (percussion, harp, etc ). Proscenium + extension lowered to level of first understage with a capacity of 65 musicians. Stage control desk Stage right, possible calls in dressing rooms, video monitoring of the stage Auditorium (classic french style) Width 27.6m Depth of parterre 28.0m Depth of balcony 33.0m Height below dome 13.8m Seating capacity Parterre 1084 Balcony 730 Loges 30 3 seats for wheeling chairs Control rooms Cabins located opposite the stage, behind the parterre, 25 m from the scene edge. Ability to place the boards inside the parterre, directly below the balcony (seats capacity decreased according seating plot p. 11). p. 3 / 13

4 LIGHTING Power supply 200A on powerlock400 at stage right 1 CEE 125A plug at stage right 2 CEE 63A plugs at backstage Work at height Focus with a Genie lift, max height 8m Spots 24 PC ADB 1kW 4 PC Teatro 2kW 30 profiles Robert Juliat 614SX 1kW 16 /35 (8 fixed in auditorium) 20 profiles Strand 1kW 15 /42 (booms on the floor) 6 profiles Robert Juliat 714SX 2kW 13 /40 6 profiles Strand 2kW (fixed at FOH) 15 profiles ETC zoom 750W 15 /30 (fixed at FOH) 2 profiles ETC fixed angle 750W 26 (fixed for conductor) 36 PAR64 (lamps CP 60, 61, 62) 1kW 44 PAR64 Led Ignition RGB + cold white (8 fixed on booms) 8 cyc ADB ALC4 Led 9 moving head VariLite VL1000 (FOH) 12 Martin MAC700 moving head (available for rental) Accessories : iris, gobo-holders, filter-holder, barndoors Stands 8 booms on wheels. Rigging height at 80cm, 140cm et 200cm 15 floor stands 6 stands, h : 2m 4 stands, h : 4m / max load : 40kg p. 4 / 13

5 Controls, power and network 1 pupitre ETC ION light board with 2 monitors. 204 dimmers 10A 12 dimmers 25A Artnet network et DMX distribution (4 universes) Follow spots Power sockets (16A et 32A) and intercom network connections are positioned behind seats 27 et 28 in row D of the balcony. 2 followspots can be installed at the balcony without changing the seats capacity. p. 5 / 13

6 SOUND AND VIDEO Power supply 1 CEE63A (3L+G+N) plug stage left + right 1 CEE16 (3L+G+N) plug at the control desk 1 CEE16 (3L+G+N) plug at the balcony Main sound system 24 L-Acoustics KARA, 2x8 LF + 1x 3 HF, 139dB 10 L-Acoustics SB18 1x18", 136dB 5 L-Acoustics X8 1x8''LF + 1''HF, 127dB, (front-fill) 10 L-Acoustics LA4X amplified controler with PFC, 4x1000W/8 Ohms, AES/EBU 2 Four Audio DB01, Break Out Dante with 8x AES + Analog Monitors FOH 6 L-Acoustics X15 HiQ, 1x15''LF + 1x3''HF, 136dB 2 L-Acoustics LA8 4x1800W/4ohm, AES/EBU 10 K & M 214/6 stands, 50kg, 2.2m 10 L-Acoustics X-US1215 stands 2 K&M stands, max 1605mm available for rental: 10 L-Acoustics X15 HiQ, 1x15''LF +1x3''HF, 136dB 3 L-Acoustics SB18 1x18" 136dB 5 L-Acoustics LA8 4x1800W/4ohm, AES/EBU splitters, multi, stagebox, electric supply 1 Yamaha CL5 Digital mixing console, St, 24 MIX, 8 Matrix, DANTE 1 Yamaha RIO3224-D DANTE, 32 mic/line inputs - remote head amps, 16 line outputs, 4 Stereo AES/EBU 1 Yamaha RIO1608-D DANTE, 16 mic/line inputs - remote head amps, 8 line outputs 1 stage-control desk connection (2x CAT7a Ethercon + 2x OpticalCon Duo +1x 32 pairs analog shared ground) 1 stage<->control desk connection 8 pairs XLR analog/digital (110Ω) isolated ground 2 Labgruppen LM44 Lake Speaker Processor 4in/4out, AES/EBU, Dante 1 Tablett PC Samsung available for rental: 1 Soundcraft Vi4 64in/32out, analog, 4x DSP. 1 Splitter 60 lines, 2 outputs transfos Jensen passives + 3 direct outputs p. 6 / 13

7 Microphones & DI Wired microphones : 2 AKG C414XLII 6 AKG C451B 6 AKG C Sennheiser MD421 2 Sennheiser e609 4 Sennheiser e904 2 Shure Beta57A 1 Shure Beta52A 4 Shure BETA91 14 Shure SM58 8 Shure SM57 2 Beyerdynamic M88 4 Neumann KM184 6 Crown PCC160 2 DPA 4098 gooseneck hypercardioïd, 45cm 4 Audio-Technica ATM 450 static 4 Audio-Technica ATM650 dynamic 1 Schoeps stéréo ORTF static MK4 1 Audio-Technica AE2500 static/dynamic 5 BSS AR133 DI box active 12 Radial J48 DI Active 3 Radial JPC MKII AV stereo direct box active for PC wireless microphones : 2 HF Sennheiser Serie 2000 (headset cardio ou hand e965) microphones stands : 14 K & M 260/1 round stands 16 K & M 259 short stands 28 K & M 210/9 stands 8 K & M 252 stands 6 table stands available for rental: wireless microphones : 2 Shure UR4D+-J5E Receiver diversity 2 channels MHz 4 Shure UR1-J5E transmitters MHz 4 Shure UR2-J5E SM58 transmitters MHz 2 Shure UA874WB Active antenna 7dBi MHz 6 Line 6 HS70T headset microphones chair omni TA4F p. 7 / 13

8 Sound sources 2 SD card Player Denon DNF650R with autopause + 1x Remote Controller RC-F400S 1 CD Player Denon DN-C615 Intercommunication 8 intercoms HF Telex. 4 intercoms ASL. 1 base station at the control desk Video coaxial BNC network between control room and different places of the stage. 1 fixed color camera on the balcony. 1 color monitor at the control desk on stage (stage right). p. 8 / 13

9 STAGE AND ORCHESTRA EQUIPMENT Drapes and borders height width 10 Legs drops 10m 4m 3 Borders 3.50m 16m 3 Borders 4m 14m 2 Half tab 10.80m manual track 1 Small tab 8m 7m 1 White cyclorama 10m 18m 1 Grey backlitscreen 8m 16m Risers 2 risers 4m x 3.5 m, height 0.60m 2 risers 4m x 1.5 m, height 0.40m 1 riser 6m x 3m, height 0.60m 1 riser 6m x 1.5m, height 0.40m 1 riser 8m x 1.5m, height 0.20m 6 risers 2m x 1m, adjustable height Dance floor and barres Entire stage can be covered in black or light grey Marley.. 34 supports and 17 barres 4 m Pianos Available for rental 1 piano 186cm (baby grand) Yamaha C3 1 piano Atlas upright 1 tuning the day of concert is included in the rent price Music stands 70 black music stands p. 9 / 13

10 DRESSING ROOMS AND CATERING SPACE All the dressing rooms have sanitary installations: showers and bathrooms. Only the conductor s dressing room has a private shower and bathroom. Sound monitors are available in all dressing rooms > plans of dressing rooms on demand Name Size Location Description 1&2 1 p. ground SL Private dressing room 3&4 1 p. up ground SL Private dressing room 5 10 p. up ground SL Shared dressing room 6 16 p. 1 st floor SL Shared dressing room 7 16 p. 2 nd floor SL Shared dressing room 8 10 p. 1 st floor SR Shared dressing room 9 18 p. 2 nd floor SR Shared dressing room 11 8 p. backstage Make-up room 12 8 p. backstage ironing, laundry Conductor 1 p. understage Private dressing room Musicians 60 p. understage Shared dressing room Extras 30 p. understage Shared dressing room Catering space A space for catering of 150 m 2 is available backstage, equiped with tables and chairs. You can use a small kitchen, with hot water and one CEE63 plug. Gas cooking is not authorized. Phone and internet Open wireless WiFi is available in the theater. Phone line can be connected on demand p. 10 / 13

11 HOUSE PLAN SEATING CAPACITY Seats Foldup seats Total Parterre Balcony Total Wheel chair location: 3 seats If you need to put the control desks at the center of the parterre, the seating capacity is modified : Table of 2m x 1m : minus 11 seats Row S 1,2,3,4,5 / Row T 1,2,3,4,5,6 Table of 4m x 1m : minus 19 seats Row S 1,2,3,4,5,7,9,11,13 / Row T 1,2,3,4,5,6,7,9,11,13 Table of 8m x 1m : minus 27 seats Row S 1,2,3,4,5,6,7,8,9,10,11,12,13 / Row T 1,2,3,4,5,6,7,8,9,10,11,12,13,14 p. 11 / 13

12 ACCESS PLAN AND PARKING Artist s entrance and service lift are at chemin du Presbytère 2. Localisation GPS : 46 31'45.8"N 6 37'18.8"E Theater has one parking for one bus / truck. Power electricity CEE32 or CEE16 available. Others parkings can be arranged on demand Truck authorization SORTIE Switzerland is not a part of UE, and the truck heaviest than 3,5t can t drive at night between 10pm and 5am and on TRANSITAIRE sundays. Special authorization can be ELEVEURS obtained on request. EXPOSANTS SORTIE p. 12 / 13 ENTREE

13 p. 13 / 13

14 SON CEE P P P P P3 9 P P Rideau rouge plan général scène Théâtre de Beaulieu Local Son RAMPE ENTRE ETAGE Pente env. 8.50% Stéphane Gattoni TdB scene 2016.vwx COORDINATION TECHNIQUE LOGE 1:100 LOGE A4 v1 DEGAG. D'EVAC. Passage des contrepoids ENTREE LOGES Accès arrière s Porte de 200 x Marche de 15c DEGAGEMENT D'EVACUATION 2 portes coulissantes dégageant sur l'arrière scène Ouverture 12 m et hauteur 6,45m 12m m55 31 CEE63 CEE63 12m m m72 P7 11m m m m55 P6 10m m m m m m55 P5 7m m65 17 Passerelle m m m30 P4 Passerelle 4m m m10 P3 3m65 9 3m20 P2 CEE63 2m75 2m m85 5 1m55 4 1m25 P1 0m95 3 0m69 2 CEE125 3x200A powerlock 0m43 0m 1 Rideau de fer 0 CEE63 Local Lumière -0m80 Pont proscenium NEZ DE SCENE PROSCENIUM / FOSSE

15 Tuyau Portes coulissantes Ouverture Maxi 12m x H: 6,45m Pont proscenium / 500 kg Pont face / 500 kg 1t Ouvertures dans plafond Coupe scène + salle Théâtre de Beaulieu Stéphane Gattoni TdB scene 2016.vwx COORDINATION TECHNIQUE 1:100 A4 v1 2ème passerelle à 13,15m P P P P P3 9 P P ère passerelle à 9m Ouvertures dans plafond 1t 685 Ouvertures latérales pour projecteurs tubes diamètre 50 Rideau de fer pente 3.6 %

16 Plan des porteuses Perche Charge maxi Type Remarques Pont face 500 dan rectangle H 40 R studio de musique + automatiques Pont casquette 500 dan rectangle H 40 R Noir - studio de musique + blinders dan américaine guillotine noire 2 rideau rouge dan américaine pendrillons P1 500 dan rectangle H 40 R 12 circuits de 2,2 kw + 2 DMX + studio de musique dan américaine dan américaine dan américaine frise dan américaine pendrillons P2 500 dan carré X30V dan américaine P3 500 dan rectangle H 40 R 12 circuits de 2,2 kw + 2 DMX + studio de musique dan américaine frise dan américaine pendrillons P4 500 dan carré X30V dan américaine dan américaine dan américaine frise dan américaine pendrillons P5 500 dan carré X30V 12 circuits de 2,2 kw + 2 DMX dan américaine dan américaine dan américaine frise dan américaine pendrillons dan américaine P6 500 dan rectangle H 40 R 12 circuits de 2,2 kw + 2 DMX dan américaine dan américaine frise dan américaine P7 500 dan carré X30V stockage dan américaine dan américaine dan américaine dan américaine

Technical rider Update : September 2018

Technical rider Update : September 2018 Technical rider Update : September 2018 Théâtre de Beaulieu Phone : +41 21 643 99 20 Av. des Bergières 10 1004 Lausanne Manager : Florence Mury-Favrod Tél : +41 21 643 99 29 florence.favrod@theatredebeaulieu.ch

More information

Main Stage Technical Specs - Hall #2

Main Stage Technical Specs - Hall #2 Main Stage Technical Specs - Hall #2 Proscenium: - Height:...20' (06.10m) - Width:...31' 10"(09.70m) Apron: - Depth:...4' (01.22m) - Width:...45' 6" (13.87m) - Height:...3' 7" (01.09m) Stage: - Maximum

More information

Technical Information

Technical Information 5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members

More information

Technical Specifications Nov 2016

Technical Specifications Nov 2016 Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The

More information

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014 Technical rider update : 10th feb 2014 Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014 Equipe Booking : mm - Michaël Monney touring@nicoleseiler.com Tel +41 (0)21 566 70 32 Tech

More information

There are 10 dressing rooms in Theatre Kerkrade.

There are 10 dressing rooms in Theatre Kerkrade. Theatre Kerkrade Dressing rooms: There are 10 dressing rooms in Theatre Kerkrade. nr1. ± 3 persons douche and toilet ±7,5m 2 Ground Level nr2. ± 2 persons douche and hand basin ±6m 2 first floor nr3. ±

More information

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com PHOTO : SÉBASTIEN DION TECHNICAL RIDER A PROPERTY OF ADRESS 252, rue Saint-Joseph Est Québec (Québec) MANAGEMENT 240, rue Saint-Joseph Est Québec (Québec) G1K 3A9 General phone: 418.523.2227 FAX: 418.523.4449

More information

Patriots Theater at the War Memorial Technical Data

Patriots Theater at the War Memorial Technical Data Patriots Theater at the War Memorial Technical Data Stage House Dimensions Proscenium Opening: 50-0 wide x 25-0 high Batten Travel: 48-10 Batten Length: 60-0 Stage depth: 26 smoke pocket to back wall Pit

More information

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted) Technical Information Stage: Proscenium arch with apron SL Wall - SR Wall: 14.99m Setting Line - U/S Fly Bar: 7.57m Setting Line (under pros, DS edge when orchestra pit out) Back Wall: 8.17m Proscenium

More information

THEATRE EQUIPMENT DECEMBER 2017

THEATRE EQUIPMENT DECEMBER 2017 THEATRE EQUIPMENT DECEMBER 2017 Stage Stage opening (permanent): width 10m & height 6m Proscenium opening (adjustable): width 9m 11m Proscenium bridge: adjustable in height Working height underneath the

More information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018 GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither

More information

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7 LOAD IN The Victoria Theater stage is directly accessible via loading dock

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange

More information

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Les Docks / Av. de Sévelin Lausanne. Technical Rider Technical Rider Technical Rider «Les Docks», updated 20.10.2017 1. Address / Contact Address : LES DOCKS Av. de Sévelin 34 (zone B) 1004 Lausanne Switzerland Phone : +41 21 623 44 44 Fax : +41 21 623 44

More information

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Phil L. Thomas Performing Arts Center Shiprock, New Mexico Phil L. Thomas Performing Arts Center Shiprock, New Mexico Technical Specifications STAGE DIMENSIONS Proscenium 45-4 wide x 24 high Proscenium to up stage wall 29 6 (from back of proscenium opening wall)

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information WRIGHT AUDITORIUM TECHNICAL INFORMATION 1. Contact Information 2. General Information 3. Dimensional Information House Goods House Accessories Dressing Rooms (Description) 4. Lighting Information Lighting

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

Main House Technical Specification

Main House Technical Specification Main House Technical Specification Technical Stage Manager: Assistant Technical Stage Manager: Nearest train station: Christchurch Population: 47,300 Distance to London: 105 miles Shaun Luckly Tel: 01202

More information

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015 THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015 CONTACTS Matt Schliesman, Executive Director 913 South 8 th Street Email: matts@cccshows.org Peggy A.

More information

Sandusky State Theatre Technical Specifications

Sandusky State Theatre Technical Specifications Sandusky State Theatre Technical Specifications Updated Jan 14, 2014 Tim Kostel Technical Director Sandusky State Theatre 107 Columbus Ave. Sandusky, OH 44870 419.626.1347 419.626.9835 fax tkostel@sanduskystate.com

More information

Matt Dann Cultural Centre

Matt Dann Cultural Centre Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:

More information

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall ALL INFORMATION SUBJECT TO CHANGE Last Updated 7/26/2017 THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall The striking art-deco interior of the 2,799-seat Mortensen Hall stands in contrast to

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

Monty Kultuurfaktorij Technical Rider

Monty Kultuurfaktorij Technical Rider Monty Kultuurfaktorij Technical Rider Stage Sound Mixing consoles: 1x Soundcraft SI Performer Amplifiers: flightcaserack with: 1x Crown XTi 1000 1x Crown CTs 3000 + system controller EAW UX8800 flightcaserack

More information

Technical Services and Specification

Technical Services and Specification Technical Services and Specification BRAUNTEX PERFORMING ARTS THEATRE ASSOCIATION, INC. 290 West San Antonio New Braunfels, TX 78130 (830) 627-0808 FAX (830) 627-0809 Operations Manager: Ben Nowotny -

More information

Dr JOHN GALLAGHER CONCERT CHAMBER

Dr JOHN GALLAGHER CONCERT CHAMBER 1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium

More information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION Stage Stage Dimensions: Theater dimensions: Mainstage - 60 0 wide x 28 9 deep. Proscenium arch - 41 6 wide x 28 0 tall. Load gallery on SR

More information

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre) Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Concert Hall Technical Specifications

Concert Hall Technical Specifications Concert Hall Technical Specifications Revised 12-14-2017 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for

More information

DEREHAM MEMORIAL HALL

DEREHAM MEMORIAL HALL DEREHAM MEMORIAL HALL is a multi purpose venue incorporating a 294 seat proscenium arch theatre. A standard stage, lighting and sound rig as set out below will be provided, unless otherwise agreed. Any

More information

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway INCOMPLETE AS OF 09-04-2017 DRAFT PURPOSES ONLY 1 of 13 Contents Contents Pg 2 Address Pg 3 Staff Pg 3 Telephone

More information

SHUBERT THEATER 247 College Street, New Haven, CT

SHUBERT THEATER 247 College Street, New Haven, CT SHUBERT THEATER 247 College Street, New Haven, CT 06510 203-624-1825 TECHNICAL SPECIFICATIONS and EQUIPMENT INVENTORY HALL SEATING CAPACITY Orchestra 665 Mezzanine 474 Balcony 392 Boxes 60 TOTAL 1591 STAGE

More information

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre) Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated Technical Rider Technical Rider Docks, updated 17.10.18 1. Address / Contact Address : LES DOCKS Av. de Sévelin 34 (zone B) 1004 Lausanne Switzerland Phone : +41 21 623 44 44 Fax : +41 21 623 44 45 Website

More information

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated. Technical Specification Adrian Sweeney Technical and Buildings Manager Office: 01483 739063 Stage Door: 01483 739040 Email: asweeney@glive.co.uk Web: GLive.co.uk 1. Auditorium Capacity Fully seated with

More information

Theatre Technical Specifications

Theatre Technical Specifications Theatre Technical Specifications The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height

More information

TECHNICAL REQUIREMENTS PAUL FORT THEATER

TECHNICAL REQUIREMENTS PAUL FORT THEATER TECHNICAL REQUIREMENTS PAUL FORT THEATER Paul Fort Theater 9 Basse-porte Street 44000 NANTES Tél. : 02 40 20 31 17 Fax : 02 40 12 42 57 Resident stage managers Michel TALPIN michel.talpin@mairie-nantes.fr

More information

Performance: Romanesco

Performance: Romanesco Technical Rider Consisting of 7 page(s) and Layout(s) Performance: Romanesco Performance length: 55 min Intermission (s): Without Choreography: Young Soon Cho-Jaquet Music: Jeremy Conne Lights: Quentin

More information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Technical Specifications: Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Proscenium Opening Height: 16 ft. Width: 36 ft. Drapes in, approx.

More information

2017 TECHNICAL SPECIFICATIONS

2017 TECHNICAL SPECIFICATIONS 2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au

More information

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel The Tower Theatre Contact - Peter Heselden Theatre Manager Tel- 07711710925 Email- pjwh15@msn.com The Tower Theatre has a seated capacity of 285 in the auditorium with 6 wheel chair positions. The box

More information

CENTRE FOR PERFORMING ARTS

CENTRE FOR PERFORMING ARTS CENTRE FOR PERFORMING ARTS Venue, Facilities & Equipment CPA VENUE AREA SIZE FUNCTION Dressing Room (Female) 6 x 12m Dress and makeup room with attached toilet and shower facilities Dressing Room (Male)

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

TECHNICAL REQUIREMENTS

TECHNICAL REQUIREMENTS BY CHRISTIANE JATAHY TECHNICAL REQUIREMENTS This technical file is the basic technical requirements for a standard venue. They are indicative and will be completed according to particular venues, by means

More information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3 Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning

More information

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422 T1 National Theater Total Seating Capacity: 1714 + 10 wheelchair spaces Total Orchestra Pit seats: 93 Orchestra Pit Section 1: 44 Orchestra Pit Section 2: 49 Auditorium (Basement 1): 324 Under Balcony

More information

Technical specifications Main theatre. Sound

Technical specifications Main theatre. Sound Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 4 stereo line inputs 4 stereo Lexicon effects engines Stagebox: Soundcraft Mini Stagebox 32R 32 analogue inputs 8 analogue outputs 4 AES Out

More information

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3 2017 Technical Specs updated: Jan 2017 Executive Director: Greg Ray Technical Director: Vonny Boarts Email: vonny@thestatetheatre.org www.thestatetheatre.org SEATING CAPACITY The State Theatre features

More information

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Rhodes Arts Complex Bishops Stortford. Technical Specifications Rhodes Arts Complex Bishops Stortford Technical Specifications Auditorium Seats up to 299 on retractable raked seating including balcony and 4 optional flat rows at floor level. At capacity there is a

More information

Technical Specification

Technical Specification Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com

More information

Technical Rider. (last update: Jan. 2016) For more info: Yves Moquin, technical director (514)

Technical Rider. (last update: Jan. 2016) For more info: Yves Moquin, technical director (514) Technical Rider (last update: Jan. 2016) For more info: Yves Moquin, technical director (514) 608-1114 sodatech@hotmail.com Contact... 2 Loading dock... 2 Stage... 2 Dimensions... 2 Stage dressing... 2

More information

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062 Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062 General Specifications Mabee Performing Arts Hall The Mabee Performing Arts Hall is located in the Bell Cultural

More information

There are 2 dressing rooms dedicated to the RABOzaal. Each room has at least 1 hand basin.

There are 2 dressing rooms dedicated to the RABOzaal. Each room has at least 1 hand basin. INGzaal Dressing rooms: There are 2 dressing rooms dedicated to the RABOzaal. Each room has at least 1 hand basin. nr11. ±4 persons ±22m 2 1 douche 1 toilet nr12. ±4 persons ±22m 2 1 douche 1 toilet Each

More information

QUAI BERIGNY DIEPPE CEDEX PHONE : FAX :

QUAI BERIGNY DIEPPE CEDEX PHONE : FAX : TECHNICAL REQUIREMENTS Update 03/15/16 QUAI BERIGNY 76374 DIEPPE CEDEX PHONE : 02.35.82.04.43 FAX : 02.32.90.00.34 SITE WEB : www.dsn.asso.fr D.S.N. Dieppe 1 TECHNICAL STAFF Technical Director : PIERRE

More information

Technical Specification

Technical Specification Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Pentas 2 The Kuala Lumpur Performing Arts Centre (klpac) Updated: 15 th July 2017 Table of Contents 1. General - Stage - Back Stage / Stand-by Area - Dressing Rooms - Security 2. Staging

More information

Concert Hall Technical Specifications

Concert Hall Technical Specifications Concert Hall Technical Specifications Revised 11/1/2014 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for

More information

Jane Mallet Theatre Technical Specifications

Jane Mallet Theatre Technical Specifications TECHNICAL SPECIFICATIONS Stage Technician Unions Stage I.A.T.S.E. Local 58 Stage Door Entrance Scott Street (West side of building South of Front St.) Seating Capacity Lower Orchestra 252 Cross Aisle*

More information

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax 1400 MARKET STREET ST LOUIS, MISSOURI 63103 314-499-7600 Main Number 314-499-7601 Main Fax www.peabodyoperahouse.com MATTHEW DEWEY GENERAL MANAGER Tel: 314-499-7700 Cell: 913-209-5148 Email: mdewey@peabodyoperahouse.com

More information

STAGE: Dimensions of the stage of the Lopez de Ayala theatre

STAGE: Dimensions of the stage of the Lopez de Ayala theatre STAGE: Dimensions of the stage of the Lopez de Ayala theatre PROSCENIUM 13m wide x 8.5m high to main border DEPTH: 12,55m from tie to wall WIDTH: 17,70m HEIGHT TO GRID: 28m WINGS Left =3,61m Right =3,65m

More information

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy Festival City Theatres Trust Festival Theatre Technical Specification Smoking Policy It is the policy of Festival City Theatres Trust that all of our workplaces are smoke-free and all employees and visiting

More information

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Technical Rider. For more info : Simon Vaillancourt, Technical director (514) Technical Rider For more info : Simon Vaillancourt, Technical director (514) 572-3736 simon@clubsoda.ca Contact info 1225 Saint-Laurent Blvd., Montreal (Qc) H2X 2S6 Phone : 514-286-1010 Fax : 514-844-2571

More information

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013 Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013 27 West Main Street Norwich, NY 13815 www.chenangoarts.org 607-336-2787 Table of Contents AUDITORIUM... 2 STAGE... 2 RIGGING...

More information

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL. TECHNICAL INFORMATION MAIN HOUSE STAGE DIMENSIONS The main stage is a flat floor sprung hardboard stage with a proscenium opening of 10.5m x 9.1m depth. The proscenium height is variable by the house border

More information

Dale F. Halton Theater Technical Specifications

Dale F. Halton Theater Technical Specifications Dale F. Halton Theater Technical Specifications Mailing Address Dale F. Halton Theater Overcash Performing Arts Center Central Piedmont Community College P. O. Box 35009 Charlotte, North Carolina 28235-5009

More information

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall ALL INFORMATION SUBJECT TO CHANGE Last Updated 1/8/2015 THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall The striking art-deco interior of the 2,799-seat Mortensen Hall stands in contrast to

More information

Technical Information

Technical Information Technical Information Gracie Fields Theatre, Oulder Hill Leisure Complex, Hudsons Walk, Rochdale, Lancashire OL11 5EF Administration: Nikki Jackson Theatre Manager T: 07824 374913 E: nikki@graciefieldstheatre.com

More information

Theatre Technical Specification

Theatre Technical Specification Theatre Technical Specification The information contained in this specification details the standard technical provision offered by the Brewhouse for visiting companies, artists and hirers. It details

More information

Technical Specifications and Inventory Spring 2018

Technical Specifications and Inventory Spring 2018 African American Performing Arts Center Technical Specifications and Inventory Spring 2018 Annette Caine, Executive Director 505-222-9756 annette@aapacnm.org James Lewis, Facility Manager 505-222-0778

More information

Technical Specification (Drama Theatre)

Technical Specification (Drama Theatre) Technical Specification (Drama Theatre) 1 TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Technical Specification. Updated: April 2016

Technical Specification. Updated: April 2016 Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:

More information

Technical Specifications

Technical Specifications Technical Specifications Technical Manager: Kevin Wilkins kbw@canford.com 01202 847543 Theatre Administrator layardtheatre@canford.com 01202 847529 All equipment is subject to availability. Please check

More information

Technical Specifications

Technical Specifications Information and scheduling for the following services and equipment are coordinated through the Stafford Centre s Technical Production Department. Technical and/or production requirements Facility information

More information

ISLAND HALL TECHNICAL INFORMATION

ISLAND HALL TECHNICAL INFORMATION ISLAND HALL TECHNICAL INFORMATION Lagan Valley Island, The Island, Lisburn, BT27 4RL Telephone: 028 9250 9250 (Reception) If you have any queries regarding this technical information please contact either:

More information

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston Studio Theatre Technical Specifications Theatre Manager Kim Scarlata 209.831.6205 Box Office Coordinator Laura Johnston 209.831.6208 Theatre Operations & Technical Assistant Matthew Morgan 209.831.6275

More information

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115 Egyptian Theatre 135 N. Second Street DeKalb, Illinois 60115 Telephone: (815) 758-1215 Box Office: (815) 758-1225 Fax: (815) 748-3292 Owned & Operated by: Preservation of Egyptian Theatre (P.E.T.) a 501(c)(3)

More information

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point) TECHNICAL RIDER STAGE Main stage Proscenium opening Front stage Back stage Grid Floor Ballet floor Stage height 32 m wide x 13 m deep (from setting line / mid point) max. 18 m - min. 12 m - max. 9 m high

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

INFORMATION FOR VISITING COMPANIES

INFORMATION FOR VISITING COMPANIES INFORMATION FOR VISITING COMPANIES 2 Middlesbrough Theatre The Avenue Linthorpe Middlesbrough TS5 6SA ADMINISTERED BY MIDDLESBROUGH COUNCIL CULTURAL SERVICES Touring Drama, Dance, Music and Opera, Amateur

More information

Technical Specifications Updated 01/10/2017. Stage

Technical Specifications Updated 01/10/2017. Stage Stage Capacity Setting Line Stage Please see your contract for capacity. Setting line(s) is 1.35m from the step of row A of the seating bank or 1.35 from the onstage edge of seats. All fire paths should

More information

UNIVERSITY CONCERT HALL. Technical Specification

UNIVERSITY CONCERT HALL. Technical Specification UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing

More information

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013 TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA 01420 UPDATED March 2013 Cultural Affairs Office: 978-665-3709 Web Site: www.fitchburgstate.edu/cultural

More information

Main House Technical Specifications

Main House Technical Specifications Main House Technical Specifications Technicians Senior Technician - Stephen Payne Technician - Drew White Technician - Joanne Marshall Arena Theatre Wulfruna Street Wolverhampton WV1 1SE Tel: 01902 321

More information

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam technical rider version August 2015 People s Place Stadhouderskade 5-6 1054 ES Amsterdam Technical Rider 2 Index Index... 2 1. Audio... 3 1.1 PA System Stage Area (Main setup)... 3 1.2 PA System Stage

More information

TECHNICAL INFORMATION & SERVICES

TECHNICAL INFORMATION & SERVICES TECHNICAL INFORMATION & SERVICES Built in 1931, the historic 2,997-seat Pasadena Civic Auditorium is one of the most revered performance halls in the nation. The Civic has played host to Broadway musicals,

More information

Technical Rider. Update: may 6th 2008

Technical Rider. Update: may 6th 2008 Cie Nicole Seiler /// NINGYO Technical Rider Update: may 6th 2008 Team Booking: Tutu Production diffusion@nicoleseiler.ch Véronique Maréchal et Simone Toendury T +41 (0)22 310 07 62 Mobile +41 (0)76 562

More information

NORTH CHARLESTON PERFORMING ARTS

NORTH CHARLESTON PERFORMING ARTS NORTH CHARLESTON COLISEUM NORTH CHARLESTON PERFORMING ARTS CENTER CHARLESTON AREA CONVENTION CENTER R. Keith Summey David R. Holscher Mayor General Manager NORTH CHARLESTON PERFORMING ARTS CENTER FACILITY

More information

The Haymarket Basingstoke Technical Specifications

The Haymarket Basingstoke Technical Specifications The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information

More information

HIRE AND TECHNICAL INFORMATION

HIRE AND TECHNICAL INFORMATION HIRE AND TECHNICAL INFORMATION 2 Table of Contents Stage Information... 3 Accommodation... 4 Lighting Equipment... 5 Sound Equipment... 7 In-House Cloths... 8 Stage Plan... 9 Contact Information.. 10 Parking

More information

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018! LOCATION ADDRESS GPS A38 Ship - Budapest Henryk Slawik lower quay (Petőfi Bridge Buda side) H-1117 Budapest lat=47.476528, lon=19.06292 PHONE 0036 1 464 39 40 FAX 0036 1 464 39 45 WEBSITE E-MAIL PROHIBITED

More information

AKI STUDIO THEATRE Information and Technical Specifications

AKI STUDIO THEATRE Information and Technical Specifications Information and Technical Specifications CONTACT Aki Studio Theatre Daniels Spectrum 585 Dundas Street East, Suite 120 Toronto ON M5A 2B7 Box Office: 1-800-204-0855 boxoffice@nativeearth.ca Native Earth

More information

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony THEDANFORTH.COM GENERAL INFO CAPACITY GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony BR OADVIEW AVE ERIN DALE AVE

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION Wyvern Theatre Theatre Square Swindon SN1 1QN Admin: 01793 535534 Ticket Office: 01793 524481 TECHNICAL SPECIFICATION Access & Parking: The Loading Dock and Stage Door are located at the end of Islington

More information

Technical Specifications salle Léo-Poulin

Technical Specifications salle Léo-Poulin Technical Specifications Salle Léo-Poulin 300 Martin St. Edmundston, NB E3V 2N6 1 of 22 Director of the Eric Marquis, Vice-principal, Cité des jeunes A.-M.-Sormany (506) 735-2008 / eric.marquis@nbed.nb.ca

More information

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5 Lighting -Lighting control PC with Horizon software and a 24 sub master wing. 2 Universes of DMX distributed via PathPort nodes. Our standard rep plot features 2 full stage back light washs of 20 PAR 64

More information

Technical Specification (Drama Theatre)

Technical Specification (Drama Theatre) Technical Specification (Drama Theatre) 1 TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15 Technical Rider Updated 21/10/15 1. ADRESS / CONTACTS Address: Website: La Gravière Chemin de la gravière 9 1227 Acacias, Genève Switzerland www.lagraviere.net Technical Cyril Borde Phone: + 41 77 493

More information

Production Advance Information

Production Advance Information Production Advance Information Table of Content Venue Overview Management Contact Information Auditorium Floor Plans Stage & Rigging Summary Stage Floor Plan Audio Summary Lighting Summary Accommodations

More information