1 No.EISWKOO 18A Original om Ron EU DECLARATION OF CONFORMITY 1. Product Models/Products: D48-N Series 2. Name and address of the manufacturer: OMRON Corporation Shiokoji Horikawa Shimogyo-Ku. Kyoto Japan 3. This declaration of conformity is issued under the sole responsibility of the manufacturer. 4. Objects of the declaration: D48-N Series with direct opening operation. Safety Limit Switch 5. The objects of the declaration described above are in conformity with the relevant Union harmonisation legislation: 2006/42/EC Machinery Directive 6. References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared: EN IS014119: 2013 Clause EN115-1 :2008+A1 :2010 Signed and on behalf of: OMRON Corporation Place and date of issue: K!.--bh. ]AMh Signature: ~// ~ )t" Jc,lt~ ]R/f Name: Yoshinori Matsueda Function: Industrial Automation Company. Safety Division. Safety Product Management Group Manager Name and address of contact in EU OMRON Europe 8.V. Quality & Environment Department Attn: J.J.P.W. Vogelaar. European Quality & Environment Manager Zilverenberg GM. 's-hertogenbosch. The Netherlands 113 GQ l51845al

2 No.EISWKOO 18A Additional Information 04B-N Series with direct opening operation, Safety Limit Switch 04B-1 II 8._ 11 N Ill IV V 123 VI - Basic Type II -Conduit Variation 1 - PG G1/2 3-1/2-14NPT 4 - M20 by PG13.5 (3 conduits type) 6 - G1/2 (3 conduits type) 7-1/2-14NPT (3 conduits type) 8 - M20 by 1.5 (3 conduits type) Ill- Switch Mechanism 1-1 NC/1 NO (Snap action) 3-1 NC/1 NO (Snap action, gold plated contact) 5-1 NC/1 NO (Slow action) 6-1 NC/1 NO (Slow action, gold plated contact) 7-1 NC/1 NO (Slow action, make before break type) 8-1 NC/1 NO (Slow action, make before break type, gold plated contact) A - 2NC (Slow action) B -2NC (Slow action, gold plated contact) IV - Actuator 11 - Roller lever (R31,5) 15 - Stainless roller lever 18 - Bearing roller lever 1F -Roller lever (45 form lock) 1R - Roller lever (R33, 7) 70 - Top plunger 71 -Top roller plunger 73 -Cross roller plunger 2/3 GQ Al

3 No.EISWKOO 18A V - Indicator and Switch Rating Blank - AC-15 le = 2 A Ue = 400 V lthe = 20 A VI - Customer Code Blank - Standard - # -With customer code maximum 6 digits letter(s) and I or number(s) 3/3 GQ Al

4 No.EISWK0019A Original om Ron EU DECLARATION OF CONFORMITY 1. Product Models/Products: D48-N Series 2. Name and address of the manufacturer: OMRON Corporation Shiokoji Horikawa Shimogyo-Ku. Kyoto Japan 3. This declaration of conformity is issued under the sole responsibility of the manufacturer. 4. Objects of the declaration: D48-N Series without direct opening operation. Safety Limit Switch 5. The objects of the declaration described above are in conformity with the relevant Union harmonization legislation: 2006/95/EC Low Voltage Directive (valid until 19 April 2016) 2014/35/EU Low Voltage Directive (valid from 20 April 2016) 6. References to the relevant harmonized standards used or references to the other technical specifications in relation to which conformity is declared: EN :2004+A1:2009 Signed and on behalf of: OMRON Co~oration Place and date of issue: ~,..};L ~S h n«bj!.} fj If Signature: ~7 2-- Name: ~ Mat;ueda Function: Name and address of contact in EU OMRON Europe 8.V. Quality & Environment Department Attn: Industrial Automation Company, Safety Division. Safety Product Management Group Manager J.J.P.W. Vogelaar. European Quality & Environment Manager Zilverenberg GM. 's-hertogenbosch. The Netherlands 113 GQ Al

5 No.EISWKOO 19A Additional Information D4B-N Series without direct opening operation, Safety Limit Switch D4B _1d N - II Ill IV LD v 123 VI I - Basic Type II -Conduit Variation 1 - PG G1/2 3-1/2-14NPT 4 - M20 by PG13.5 (3 conduits type) 6 - G1/2 (3 conduits type) 7-1/2-14NPT (3 conduits type) 8 - M20 by 1.5 (3 conduits type) Ill- Switch Mechanism 1-1 NC/1 NO (Snap action) 3-1 NC/1 NO (Snap action, gold plated contact) 5-1NC/1NO (Slow action) 6-1 NC/1 NO (Slow action, gold plated contact) 7-1 NC/1 NO (Slow action, make before break type) 8-1 NC/1 NO (Slow action, make before break type, gold plated contact) A - 2NC (Slow action) B - 2NC (Slow action, gold plated contact) C - 2NO (Slow action, suffix 15 in Item IV) D - 2NO (Slow action, gold plated contact, suffix 15 in Item IV) IV -Actuator 13 -Adjustable rubber roller lever (cp50 mm) 15 -Stainless roller lever (Suffix CorD in Item Ill) 16 -Adjustable resin roller lever 17 - Adjustable metal rod lever 19 - Adjustable metal roller lever 1 E -Adjustable nylon roller lever (cp38.1 mm) 81 -Wobble lever (Coil spring) 87 -Wobble lever (Plastic rod) 2/3 GQ Al

6 No.EISWKOO 19A V -Indicator and Switch Rating Blank -Without indicator IAC-15 le=2a Ue=400V lthe= 20A Without indicator IDC-13 le=0.27a Ue=250V lthe=2.5 A (Suffix C or D in Item Ill) -LD -LED I AC-15 le=2a Ue=115V lthe=3a -LE -Neon Lamp I AC-15 le=2a Ue=250V lthe=3a VI - Customer Code Blank - Standard - # -With customer code maximum 6 digits letter(s) and I or number(s) 313 GQ l 51845Al

7 ~~--~ Zertifikat mit iiberwachter Konformitat Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 01 TUV Rheinland Ihr Zeichen Client Reference 97KH008 Unser Zeichen Our Reference CSH/moh E Z02 Ausstellungsdatum Date of Issue (day!mo!yr) Genehmigungsinhaber License Holder Omron Corp. 20 Igadera, Shimokaiinji Nagaokakyo-shi, Kyoto Fertigungsstatte Manufacturing Plant Omron Kurayoshi Co., Ltd Iwaki Kurayoshi-shi, Tottori /;;!. TUV Rheinland Gepriift nach Tested Ace. to EN :1997+A11 EN :1997+A1 Zertifiziertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Limit Switch with direct opening Lizenzentgelte - Einheit License Fee - Unit Type Designation D4B - II III IV N - V - VI II,III,IV,V,VI =see Appendix 1 6 Actuating Type Rated Operational Voltage Rated Operational Current Rated Conditional Short Circuit Current: Utilization Category IP Code ANLAGE (Appendix) 1 snap action AC 400V 2A 100A AC-15 IP67 6 Dem Zertifikat liegt unsere Priif- und Zertifizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird iiberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOln Dipl.-Ilg. R. Keller

8 Zertifikat mit iiberwachter Konformitiit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 02 TUV Rheinland Ihr Zeichen Client Reference 97KH008 Unser Zeichen Our Reference CSH/moh E Z02 Ausstellungsdatum Date of Issue (daylmolyr) Genehmigungsinhaber Omron Corp. License Holder 20 Igadera, Shimokaiinji Nagaokakyo-shi, Kyoto Fertigungsstiitte Manufacturing Plant Weida Industrial Co., Ltd. 2nd, Floor No. 5 Hongxing Industrial Bldg. Nan Ping, Zhu Hai City Guang Dong Province P.R. CHINA A TUV Rheinland Gepriift nach Tested Ace. to EN :1997+A11 EN :1997 Zertifiziertes Produkt (Geriiteidentifikation) Certified Product (Product Identification) Limit Switch with direct opening Lizenzentgelte - Einheit License Fee - Unit Addition Factory see above Dem Zertifikat liegt unsere Pruf- und Zertifizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird iiberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOin Dipl._(ng. R. Keller. 10/

9 Zertifikat mit iiberwachter KonformiHit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 03 TUV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our. Reference ZO-CSH Ausstellungsdatum Date of Issue (day!molyr) Genehmigungsinhaher License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigungsstatte Manufacturing Plant Omron Kurayoshi Co., Ltd Iwaki KURAYOSHI-SHI, TOTTORI A TUV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit switch with direct opening Changes Test Requirement changed to EN :1997+A11 (see above) ".-..~.dress of License Holder changed to Omron Corp. 20 Igadera, Shimokaiinji Nagaokakyo-shi, Kyoto , Japan (see above) ANLAGE (Appendix) : 1 Dem Zertiftkat liegt unsere Pruf- und Zertijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird uberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TDv Rheinland Product Safety GmbH, Am Grauen Stein, D Koln Zertifizierungsstelle Dipl.-Ing. W. NOlkc 10/

10 Zertifikat mit iiberwachter Konformitat Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 04 TUV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (daylmo!yr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SRI, KYOTO Fertigungsstatte Manufacturing Plant Weida!ndustrial Co., Ltd. No.252 GangCang Road, GongBei ZHU HAI, GUANG DONG P.R. CHINA /:A TOY Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch with direct opening Additions Pollution Degree Rated Insulation Voltage Rated Impulse Withstand Voltage Protection Class 3 (inside 2) 600V 4KV I Factory (see above) ANLAGE (Appendix) : 1 Dem Zertifikat liegt unsere Pruf- und Zertifizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird iiberwacht. This certificate is based on our Testing and Certification Regulation. The product : fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D Koln Zertifizierungsstelle Dipl.-Ing. W. Nolke Q

11 Zertifikat mit iiberwachter Konformitiit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 05 TUV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (daylmolyr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigungsstatte Manufacturing Plant Weida Industrial Co., Ltd. No.252 GangCang Road, GongBei ZHU HAI, GUANG DONG P.R. CHINA A TOV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch with direct opening Addition for Type Designation D4B - II III IV N - V - VI II, IV, V, V! = (see Appendix 1.1) Items for suffix III= 5, 6, 7, 8, A orb 1 Actuating Type, ~,ted Operational Voltage.. ctted Operational Current Utilization Category Related Conditional Short IP Code Pollution Degree Rated Insulation Voltage Rated Impulse Withstand Voltage, Protection Class slow action AC 400V, 50-60Hz 2A AC-15 Circuit Current: 100A IP67 3 (inside 2) 600V 4kV I 1 ANLAGE (Appendix): 1.1 Dem Zenijikat liegt unsere Pruf- und Zenijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird uberwacht. This certificate is based on our Testing and Cenijication Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUV Rheinland Product Safety GmbH, Am Grauen Stein, D Koln Dipl.-lng. W. Nolke 10/

12 Zertifikat mit iiberwachter KonformiHit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 06 A TOV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (day/mo!yr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigungsstlitte Manufacturing Plant Togo Electronics Works Co., Ltd Kadota, Togo-cho TOHAKU-GUN, TOTTORI A TOV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Gerliteidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch with direct opening Addition Factory (see above) Change ctory withdrawn Weida Industrial Co., Ltd. 2nd, Floor No. 5 Hongxing Industrial Bldg. Nan Ping, Zhu Hai City Guang Dong Province P.R. CHINA TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOln Dipl.-Ing. W. Nolke

13 Zertifikat mit iiberwachter Konformitat Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 07 TUV lhr Zeichen Client Reference 02KA003 Unser Zeichen Our Reference ZO-NHA Ausstellungsdatum Date of Issue (daylmolyr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigungsstatte Manufacturing Plant Omron Izumo Co., Ltd Nishi-Hayashigi-cho IZUMO-SHI, SHIMANE Gepriift nach Tested ace. to EN :1997+A1+Al2+A2 Zertifiziertes Produkt (Gerateidentiflkation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch with direct opening Addition Factory (see above) Change otory Omron Kurayoshi Co., Ltd Iwaki Kurayoshi-shi, Tottori withdrawn. Dem Zenifikat liegt unsere Priif- und Zenijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird Uberwacht. This cenijicate is based on our Testing and Cenijication Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOin Dipl.-

14 "'' Certiflctzte KonformiHit of surveyed confonnity Blatt Page 08 A. TOV. Shimogyo... ku Fertigtii'l~stitt;e Manti]gthtring Plant omt'6n I zurno c6. I Ltd Ni~hi-Hayash,igi-cho Izumo-shi/ Shimane 69; JAJ?AN EN s~1:20o4 - Einheit -Unit.~ : 199'7+Al+Al.2+A2 (see above)

15 Zertifikat Certificate mit iiberwachter Konformitiit of surveyed conformity Zertifikat Nr. Certificate No. J Blatt Page 09.. TUVRheinland Ihr Zeichen Client Reference 10IB006 Unser Zeichen Our Reference ZJL-MTS Ausstellungsdatum Date of Issue ( day/molyr) Genehmigungsinhaber License Holder Fertigungsstiitte Manufacturing Plant Omron Corp. Togo Electronics works Co., Ltd. Shiokoji Horikawa, Shimogyo-ku Kadota, Yurihama-cho Kyoto-shi, Kyoto Tohaku-gun, Tottori Priifzeichen Test Mark A.. TUVRheinland Gepriift nach Tested ace. to EN :2004 Zertifiziertes Produkt (Geriiteidentifikation) Certified Pl'Oduct (Product Identification) Lizenzentgelte Einheit License Fee- Unit Limit Switch with direct opening Changes Factory Omron Izumo Co. 1 Ltd Nishi-Hayashigi-cho Izumo-shi, Shimane withdrawn Address of Factory changed to Togo Electronics Works Co., Ltd Kadota, Togo-cho TOHAKU-GUN, TOTTORI (see above} Zertifizierungsstelle TUv Rheinland LGA Products GmbH, TillystraBe 2, Ntirnberg Tel.: Fax: Dipl.-Ing. S. Hartter

16 TOV Rheinland Product Safety GmbH Am Grauen Stein D Koln Certificate No.: J Our reference: ZO-HHI Appendix No.: 1.2 Constructional Data Form (EN ) A TUVRheinland Page4/4 TYPE NOMENCLATURE: Nomenclature of 048-N with Direct Opening Operation I - Basic Type 048 -! A!! N 123 I II Ill IV V VI D4B II -Conduit Variation PG13.5 -G1/2-1/2-14NPT -M20 by1,5 - PG13,5 (3 conduits type) -G1/2 (3 conduits type) -1/2-14NPT (3 conduits type) - M20 by 1,5 (3 conduits type) Ill - Switch Mechanism A B -1 NC/1 NO (Snap action) 1 NC/1 NO (Snap action, gold plated contact) -1 NC/1 NO (Slow action) -1 NC/1 NO (Slow action, gold plated contact) 1 NC/1 NO (Slow action, make before break type) -1 NC/1 NO. (Slow action, make before break type, gold plated contact) - 2NC (Slow action) - 2NC (Slow action, gold plated contact) IV -Actuator F 1R Roller lever (R31,5) -Stainless roller lever - Bearing roller lever -Roller lever (45 form lock) - Roller lever (R33, 7) -Top plunger -Top roller plunger -Cross roller plunger V - Indicator and Switch Rating Blank -AC-15 Ie = 2A Ue = 400 V Ith = 20A VI - Customer Code Blank -# -Standard -With customer code maximum 6 digits letter(s) and I or number(s) V1/Jrt'll lzutntj Co./Ltd, (Place) /Hfl!/1.. 2f 211fl7 (Date) (Stamp and Signature of Applicant)

17 Zertifikat mit iiberwachter Konformitat Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 0001 TUV Ihr Zeichen Client Reference ; 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (daylmolyr) Genehmigungsinhaber License Holder, Omron Corp. 1 Shiokoj i Horikawa, Shimogyo-ku 'KYOTO-SHI, KYOTO Fertigungsstatte Manufacturing Plant Omron Kurayoshi Co., Ltd Iwaki KURAYOSHI-SHI, TOTTORI A TOV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 ZertifiZiertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Lizenzentgelte Einheit License Fee - Unit Limit Switch Type Designation D4B - II III IV N V VI II,III,IV,V,VI = (see Appendix 1) 5 3 Rated Operational Voltage Rated Operational Current Utilization Category Rated Conditional Short-Circuit Current ~->-Degree _ Jllution Degree Rated Insulation Voltage Rated Impulse Withstand Voltage Protection Class AC 400V, 50-60Hz 2A AC A IP67 3 (inside 2} 600V 4KV I DC 250V 0,27A DC-13 Remark : Reissue of R , due to standard update. 8 1 ANLAGE (Appendix) : 1 Dem Zertifikat liegt unsere Priif- und Zertijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird iiberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOin 10/

18 Zertifikat mit iiberwachter Konformitiit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 0002 ~ TOV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (daylmo!yr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigungsstiitte Manufacturing Plant Togo Electronics Works Co., Ltd Kadota, Togo-cho TOHAKU-GUN, TOTTORI A TOV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Geriiteidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch Addition Factory (see above) Dem Zenijikat liegt unsere Pruf- und Zenijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anjorderungen, die Herstellung wird uberwacht. This certificate is based on our Testing and Cenijication Regulation. The product i fulfills above-mentioned-requirements, the production is subject to surveillance. TiJv Rheinland Product Safety GmbH, Am Grauen Stein, D KOln Zertifizierungsstelle 10/

19 Zertifikat mit iiberwachter Konformitlit Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 0003 ~ TOV Ihr Zeichen Client Reference 01KA004 Unser Zeichen Our Reference ZO-CSH Ausstellungsdatum Date of Issue (daylmolyr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku ' I KYOTO-SHI I KYOTO Fertigungsstatte Manufacturing Plant Weida Industrial Co., Ltd. No.252 GangCang Road, GongBei ZHU HAI, GUANG DONG P.R. CHINA ~A_ TOV Gepriift nach Tested ace. to EN :1997+Al+A12+A2 Zertifiziertes Produkt (Gerliteidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch Addition Factory (see above) Dem Zertifikat liegt unsere Pruf- und Zertifizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird uberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D Koln Zertifizierungsstelle 10/

20 Zertifikat mit iiberwachter Konformitat Zertifikat Nr. Certificate No. J Certificate of surveyed conformity Blatt Page 0004 TUV Ihr Zeichen Client Reference 02KA003 Unser Zeichen Our Reference ZO-NHA Ausstellungsdatum Date of Issue (day/molyr) Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku KYOTO-SHI, KYOTO Fertigtmgsstatte Manufacturing Plant Omron Izumo Co., Ltd Nishi-Hayashigi-cho IZUMO-SHI, SHIMANE A TUV Gepriift nach Tested ace. to EN :1997+A1+A12+A2 Zertifiziertes Produkt (Gerateidentifikation) Certified Product (Product Identification) Lizenzentgelte - Einheit License Fee - Unit Limit Switch Addition Factory (see above) Change Factory Omron Kurayoshi Co., Ltd Iwaki KURAYOSHI-SHI, TOTTORI withdrawn. Dem Zertifikot liegt unsere Priif- und Zertijizierungsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird ilberwacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above-mentioned-requirements, the production is subject to surveillance. TUv Rheinland Product Safety GmbH, Am Grauen Stein, D KOln Zertifizierungsste 10/

21 Certificate oerwac!ntf~ 1\,oru:orrnitiit of surveyed conformity Blatt Page 0005 TUV Shimogyo-ku Fetti~~g~titte Plant Otrtf'oh Izumo., Ltd Ni~hi-Hayashigi-cho Izumo-shi, Shiman~ G-epriift nath Tested ace. to EN :2004 (Geriiteidentltikation) (Productldentijication) Lizenze~~eite - Einheit License Fee - Unit EN :1997+A1+AJ,2+A2 (see a.pove}

22 Zertifikat Certificate mit iiberwachter Konformitiit of surveyed conformity Zertifikat Nr. Certificate No. J Blatt Page TUVRheinland Ihr Zeichen Client Reference 10IB006 Unser Zeichen Our Reference ZJL-MTS Ausstellungsdatum Date of Issue ( day/molyr) Genehmigungsinhaber License Holder Fertigungsstiitte Manufacturing Plant Omron Corp. Togo Electronics Works Co., Ltd. Shiokoji Horikawa, Shimogyo-ku Kadota, Yurihama-cho Kyoto-shi, Kyoto Tohaku-gun, Tottori Prtifzeichen Test Mm* A.. TUVRheinland Geprtift nach Tested ace. to EN :2004 Zertifiziel'tes Produkt (Geriiteidentifikation) Certified PJ oduct (Product Identification) Lizenzentgelte - Einheit License Fee- Unit Limit Switch Change Factory Omron Izumo Co. 1 Ltd Nishi-Hayashigi-cho Izumo-shi, Shimane withdrawn Address of Factory changed to Togo Electronics Works Co., Ltd Kadota, Togo-cho TOHAKU-GUN, TOTTORI (see above) Dem Zertijikat iiegt unsere Priif- und Zertifizienmgsordnung zugrunde. Das Produkt entspricht den o.g. Anforderungen, die Herstellung wird iibenvacht. This certificate is based on our Testing and Certification Regulation. The product fulfills above mentioned requirements, the production is subject to sun eillance. Zertifizierungsstelle TOV Rheinland LGA Products GmbH, TillystraBe 2, 9043 I Niirnberg Tel.; Fax: Dipl.-Ing. S. Hartter

23 TOV Rheinland Product Safety GmbH Am Grauen Stein D Koln Certificate No.: J Our reference: ZO-Hlll Appendix No.: 1.1 Constructional Data Form (EN ) A * TUVHheinland Page 4/4 TYPE NOMENCLATURE: Nomenclature of 048-N without Direct Opening Operation I - Basic Type D4B N - LD I II Ill IV V VI II -Conduit Variation PG13.5 -G1/2-1/2-14NPT -M20 by 1,5 PG13,5 (3 conduits type) -G1/2 (3 conduits type) -1/2-14NPT (3 conduits type) - M20 by 1,5 (3 conduits type) Ill - Switch Mechanism NC/1 NO (Snap action) 1 NC/1 NO (Snap action, gold plated contact) -1 NC/1 NO (Slow action) -1 NC/1 NO (Slow action, gold plated contact) -1 NC/1 NO (Slow action, make before break type) 8-1 NC/1 NO (Slow action, make before break type, gold plated contact) A - 2NC (Slow action) B - 2NC (Slow action, gold plated contact) c - 2NO (Slow action, suffix 15 in Item IV) D - 2NO (Slow action, gold plated contact, suffix 15 in Item IV) IV - Actuator E Adjustable rubber roller lever ( cp 50 mm) -Stainless roller lever (Suffix C or D in Item Ill) -Adjustable resin roller lever -Adjustable metal rod lever -Adjustable metal roller lever -Adjustable nylon roller lever ( cp 38.1 mm) -Wobble lever (Coil spring) -Wobble lever (Plastic rod) V - Indicator and Switch Rating Blank -Without indicator I AC-15 Ie=-2A Ue=-400V Without indicator I DC-13 Ie=-0,27 A Ue=-250V (Suffix CorD in Item Ill) -LD -LED I AC-15 Ie=2A Ue=115V Ith=-3A -LE -Neon Lamp I AC-15 Ie=2A Ue=250V Ith=3A VI - Customer Code Blank -Standard -# -With customer code maximum 6 digits letter(s) and I or number(s) f!tnrtm lzufy!if {' p.(lt / (Place) (Date) (Stamp and Signature of Applicant)

24 5/25/2018 NKCR.E Auxiliary Devices NKCR.E76675 Auxiliary Devices If you notice a change to your NKCR Listing Card, click here to learn more. Page Bottom Auxiliary Devices See General Information for Auxiliary Devices OMRON CORP SAFETY STANDARDS GROUP IAB GLOBAL QUALITY CENTER SHIOKOJI HORIKAWA SHIMOGYO-KU, KYOTO E76675 Trademark and/or Tradename:, Investigated to ANSI/UL 508 Emergency Stop Pushbutton Switches Model(s) Series A22NE, followed by -S, -M or -L, may be followed by P, may be followed by RC, RO, RS or TN, followed by -P, followed by 0, 1, 2, A, B or C, followed by 0, 1, 2, A, B or C, followed by 0, 1, 2, A, B or C, followed by -N, -A, -B, -C, -D or -E, may be followed by -B, -S or -SB. Auxilary Device Enclosed Model(s) Switches, type D4SL-N; followed by 1, 2, 3 or 4; followed by A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q or R; followed by F or D; followed by A or G; may be followed by C or D; may be followed by 4; followed by C; followed by 1, 3 or 5 may be followed by additional letter(s) and/or number(s). Auxilary Device Enclosed Key-type Selector Switch Model(s) A22LK, followed by 2RLA or 2RLB,followed by 22,13,or 04,may be followed by K, followed by 01, may be followed by up to 10 letters and/or numbers. Auxilary Device Open type Model(s) G9SE Series followed by 2, 4, followed by 0, 2, followed by 1, followed by blank, T05, or T30. Door lock switches Model(s) D4GL, followed by 1, 2, 3 or 4, followed by A thru H or J thru M, followed by B, F, L, R, D, E, G or H, followed by A, G or N, may be followed by A, B or C, may be followed by 4, may be followed by N.* Door switches Model(s) D4BL Series, followed by 1, 2, 3 or 4, followed by C, D, E or F, followed by A, B C, D, E, F or G, followed by blank, A, B, C, D, E or F, followed by blank, or T, followed by blank or up to six letters and/or numbers. D4BS-11BSF1*, D4BS-11FSF1*, D4BS-11LSF1*, D4BS-11RSF1* D4GS-N, followed by 1, 2, 3 or 4, followed by R or T, may be followed by 3, 5 or up to two letter and/or numbers, may be followed by up to six letters and/or numbers. D4JL, followed by 1, 2, 3 or 4, followed by A thru H, J thru N or P thru R, followed by D or F, followed by A or G, followed by C or D, followed by 5, 6, 7, or 8, followed by blank, followed by blank, Y or Z, may be followed by four alphanumeric code, may be followed by six digit maximum alphanumeric code. D4N 9120GP D4N, may be followed by A or H, followed by 1 thru 9 or A, B or C, followed by 1, 2 or A thru G, followed by 20, 21, 21-TK, 22 thru 29, 2B, 2C, 2D, 2G, 2H, 2J, 2L, 31, 32, 34, 62, 63, 72, 80, 87, RE, LE, AS, BC or AS1, may be followed by R.* D4NL, followed by 1, 2, 3 or 4, followed by A thru H, J thru N, P or Q, followed by B, D, E, F, G, L or R, followed by A, B, C, D, E, F, G, H, J, K or L, may be followed by A thru F, may be followed by 4, may be followed by S, may be followed by Z.* D4NS, followed by 1 thru 9 or A, B or C, followed by A thru F, followed by B, D, E, F, G, H, L or R.* Illuminated Pushbutton Switches Model(s) Series A22N, followed by L, followed by BN, BP, BG, BM, MN, MP, MG, MM, RN, RP, or RM, followed by A or M, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by

25 5/25/2018 NKCR.E Auxiliary Devices 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Illuminated Pushbuttons Switches Model(s) Series A30N, followed by L, followed by MN, MP, MG, or MM, followed by A or M, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Illuminated Selector Switches Model(s) Series A22N, followed by W, followed by 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Series A30N, followed by W, followed by 2M or 3M, followed by M, L, R, or B, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Key Selector Switches Model(s) Series A22N, followed by K, followed 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by 01, followed by A, B, C, D, E, F, or G, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C. Series A30N, followed by K, followed 2M or 3M, followed by M, L, R, or B, followed by 01, 02, 03, 04, 05, or 06, followed by A, B, C, D, E, F, or G, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C. Lamp Block Model(s) Series A22N, followed by Z, followed by T, followed by A, B, C, D, or E follow by P or blank, followed by blank or N. Limit switches Model(s) D4A, followed by 3, may be followed by E, followed by 01-06, 07-V, 07-H, 08-12, or 24, may be followed by N, followed by GM or KGM.* D4B, followed by -1, -2, -3, -4, -5, -6, -7 or -8, followed by 1, 2, 3, 4, 5, 6, 7, 8, A, B, C or D, followed by 1 thru 8 or 00, may be followed by up to two numbers or letters, followed by N, may be followed by LD or LE.* D4B-F, followed by 1, 2, 3 or 4, followed by 1, 2 or 3, followed by 11, 15, 1F or 1R, followed by F, may be followed by 1.* D4BS, followed by -1, -2, -3, -4, -5, -6, -7 or -8, followed by 5, 6, 7, 8, A or B, followed by F, R, L or B, followed by S, may be followed by LD or LE.* D4C, followed by 10, 20, 30, A0, C0 or D0, followed by a two digit number, followed by DRAJ01 or ARAJ01.* D4C-1*, D4C-2*, D4C-3*, D4C-4*, D4C-5*, D4C-6*, D4CC-1*, D4CC-2*, D4CC-3*, D4CC-4*, D4CC-5*, D4CC-6* D4F, followed by 1 thru 5, followed by 0 or 2, followed by 0, 2, 3, G or H, followed by a number, followed by R, L or D.* SHL, followed by D, Q or W, with or without 1 or 2 digit number, followed by 55, followed by blank, followed by blank, L, L6 or L7, followed by blank, MD, ML or MR, followed by blank, 2 or 3, followed by blank, TC or TH, followed by blank or 11, followed by blank or T, followed by blank or up to six additional letters and/or numbers. WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -M1J###,- M1GJ###, -M1JB###, -DGJ###, -DGJS###, -DHJS###-A, -DK1CJ###, -DK1EJ###, -DK1EJ2###, -M1TJ###, -M1TJB###, -M1TGJ###, - DTGJ###, -DTGJS###, -DTK1EJ###, K13, K15, K17, K41, K42, K43 or K51, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or TC, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s).($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or TC, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, may be followed by A or F, may be followed by S or S2, followed by -M1J###,-M1GJ###, -M1JB###, -DGJ###, -DGJS###, -DHJS###-A, -DK1CJ###, -DK1EJ###, -DK1EJ2###, -M1TJ###, -M1TJB###, - M1TGJ###, -DTGJ###, -DTGJS### or, -DTK1EJ###, K13, K15, K17, K41, K42, K43 or K51, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or TC, may be followed by E2 or P2, may be followed by RP60U, may be followed by G1, G, Y or TS, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by RP60U, may

26 5/25/2018 NKCR.E Auxiliary Devices be followed by G1, G, Y or TS, followed by LE, may be folowed by 2 or 3, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed 55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LE, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by R, followed by C, D, G, H, NJ, or SD, followed by a number, may be followed by LD, followed by GM, KGM or K-GM.* WL, may be followed by R, may be followed by 01, may be followed by A or B, may be followed by M, followed by C#, D#, G#, H#, NJ#, or SD# where # is up to a ten-digit symbol of letter(s) and/or number(s), may be followed by E2, may be followed by RP, 10, or 31, may be followed by P1, may be followed by 55, may be followed by TC, TC2, TH, or T, may be followed by 13##, RP4##, RP5##, RP6##, or 14##, where ## is a one or two digit symbol of letter(s) and/or number(s), may be followed by G1, G, Y, TS, or C, may be followed by LE, LD, LDN, LR or R, may be followed by 2 or 3, may be followed by A or F, may be followed by S, may be followed by DGJ###, DTGJ###, DK1CJ###, DK1EJ###, DTK1EJ###, M1J###, M1TJ###, M1GJ###, M1TGJ###, M5J###, DHJS###, AGJ###, AK1EJ####, AK1J###, AK4EJ### or K###, where ### is up to a five digit symbol of letter(s) and/or number(s), may be followed by up to a five digit symbol of letter(s) and/or number(s). ZE, ZV or ZV2, may be followed by -01 or Y, followed by N or Q, followed by six letters and/or numbers, may be followed by 2, may be followed by G, G1, S or Y, may be followed by TC or TH.* Limit switches, actuator heads Model(s) D4A-0001N*, D4A-0002N*, D4A-0003N*, D4A-0004N*, D4A-0005N*, D4A-0006N*, D4A-0007HN*, D4A-0007VN*, D4A-0008N*, D4A-0009N*, D4A-0010N*, D4A-0011N*, D4A-0012N*, D4A-0014N*, D4A-0015N*, D4A-0016N*, D4A-0017N*, D4A-0018N*, D4A-0019N*, D4A-0020N*, D4A-0024N* Limit switches, bodies Model(s) D4A-0000N*, D4A-0100N*, D4A-0300N*, D4A-0500N*, D4A-0700N*, D4A-0900N*, D4A-0E00N* Limit switches, receptacles Model(s) D4A-1000*, D4A-1000N*, D4A-2000*, D4A-2000N*, D4A-3000*, D4A-3000N*, D4A-4000*, D4A- 4000N*, D4A-5000*, D4A-5000N*, D4A-6000*, D4A-6000N* Limit swtiches Model(s) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12- ##, GL##-##, GAL##-##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by RP60U, may be followed by G1, G, Y or TS, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) Magnetically actuated switches Model(s) D40B-1B10, D40B-1B3, D40B-1D10, D40B-1D3, D40B-2B10, D40B-2B3, D40B-2D10, D40B-2D3, D40B-3D5C, D40B-3E5C, D40B-A1, D40B-A2, D40B-A3, D40B-J1, D40B-J2, D40B-S1B10, D40B-S1B3, D40B-S1D10, D40B-S1D3, D40B-S2B10, D40B-S2B3, D40B-S2D10, D40B-S2D3, D40B-S3D5C, D40B-S3E5C Non-contact door switches Model(s) D40A-1C, followed by 2, 5, or a three digit number, may be followed by -F.+ D40Z, followed by 1, followed by C, may be followed by 2 or 5, may be followed by S or A.* Non-contact door switches, actuators only Model(s) D40A-A1 Non-contact door switches, sensors only Model(s) D40A-A1C2, D40A-A1C5 Pendant enable switches Model(s) A4EG-, followed by B or C, followed by 00, E1, E2, M2, P1 or P2, followed by 0, B, R, Y or G, followed by 0, followed by 1, 2 or 4, followed by 0 or 1, may be followed by SH, may be followed by up to six number(s) and/or letter(s) except for A. Pilot Light Model(s) Series M22N, followed by BN, BP, BG or BC, followed by TR, TG, TY, TW, TA, Or TO, followed by A, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E, followed by P or blank Pilot Lights Model(s) Series M30N, followed by MN, MP, MG, or MC, followed by TR, TG, TY, TW, TA, Or TO, followed by A, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E, followed by P or blank. Pushbutton Switch Model(s) Series A22N, followed by N, followed by BN, BP, BG, BM, MN, MP, MG, MM, RN, RP, or RM, followed by A or M, followed by NR, NG, NY, NW, NA, NB, UR, UG, UY, UW, UA or UO, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Pushbuttons Switches Model(s) Series A30N, followed by N, followed by MN, MP, MG, or MM, followed by A or M, followed by NR, NG, NY, NW, NA, NB, UR, UG, UY, UW, UA or UO, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Selector Switches Model(s) Series A22N, followed by S, followed by 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by NR, NG, NY, NW, NA, or NB, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Series A30N, followed by S, followed by 2M or 3M, followed by M, L, R, or B, followed by NR, NG, NY, NW, NA, or NB, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Switch Contact Block Model(s) Series A22N followed by Z, followed by S, followed by G or P, followed by 1 or 2, followed by A,B or C, followed by blank or N. Terminal relays Model(s) F3SP-T01 ($) - ##: w/wo Maximum 2 digits number(s), ###: w/wo Maximum 3 digits number(s) * - May be followed by additional number(s) and/or letter(s). + - Additional functional safety investigation was completed to UL 991 and IEC Last Updated on

27 5/25/2018 NKCR7.E Auxiliary Devices Certified for Canada NKCR7.E76675 Auxiliary Devices Certified for Canada If you notice a change to your NKCR7 Listing Card, click here to learn more. Page Bottom Auxiliary Devices Certified for Canada See General Information for Auxiliary Devices Certified for Canada OMRON CORP SAFETY STANDARDS GROUP IAB GLOBAL QUALITY CENTER SHIOKOJI HORIKAWA SHIMOGYO-KU, KYOTO E76675 Investigated to CAN/CSA C22.2 No Emergency Stop Pushbutton Switches Model(s) Series A22NE, followed by -S, -M or -L, may be followed by P, may be followed by RC, RO, RS or TN, followed by -P, followed by 0, 1, 2, A, B or C, followed by 0, 1, 2, A, B or C, followed by 0, 1, 2, A, B or C, followed by -N, -A, -B, -C, -D or -E, may be followed by -B, -S or -SB. Auxilary Device Enclosed Key-type Selector Switch Model(s) A22LK, followed by 2RLA or 2RLB,followed by 22,13,or 04,may be followed by K, followed by 01, may be followed by up to 10 letters and/or numbers. Auxilary Device Open type Model(s) G9SE Series followed by 2, 4, followed by 0, 2, followed by 1, followed by blank, T05, or T30. Illuminated Pushbutton Switches Model(s) Series A22N, followed by L, followed by BN, BP, BG, BM, MN, MP, MG, MM, RN, RP, or RM, followed by A or M, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Illuminated Pushbuttons Switches Model(s) Series A30N, followed by L, followed by MN, MP, MG, or MM, followed by A or M, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Illuminated Selector Switches Model(s) Series A22N, followed by W, followed by 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Series A30N, followed by W, followed by 2M or 3M, followed by M, L, R, or B, followed by TR, TG, TY, TW, TA, or TO, followed by A, followed by G or P, followed by 0,1,2,A,B,or C, followed by 0, followed by 0,1,2,A,B,or C, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E. Key Selector Switches Model(s) Series A22N, followed by K, followed 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by 01, followed by A, B, C, D, E, F, or G, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C. Series A30N, followed by K, followed 2M or 3M, followed by M, L, R, or B, followed by 01, 02, 03, 04, 05, or 06, followed by A, B, C, D, E, F, or G, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C. Lamp Block Model(s) Series A22N, followed by Z, followed by T, followed by A, B, C, D, or E follow by P or blank, followed by blank or N. Limit switches Model(s) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12- ##, GL##-##, GAL##-##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -M1J###,-M1GJ###, -M1JB###, -DGJ###, -DGJS###, -DHJS###-A, -DK1CJ###, -DK1EJ###, -DK1EJ2###, -M1TJ###, - M1TJB###, -M1TGJ###, -DTGJ###, -DTGJS###, -DTK1EJ###, K13, K15, K17, K41, K42, K43 or K51, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or

28 5/25/2018 NKCR7.E Auxiliary Devices Certified for Canada TC, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s).($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or TC, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, may be followed by A or F, may be followed by S or S2, followed by -M1J###,-M1GJ###, -M1JB###, -DGJ###, -DGJS###, -DHJS###-A, -DK1CJ###, -DK1EJ###, -DK1EJ2###, -M1TJ###, -M1TJB###, - M1TGJ###, -DTGJ###, -DTGJS### or, -DTK1EJ###, K13, K15, K17, K41, K42, K43 or K51, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, RP, RP7, RP8, RP9 or E10, may be followed by 55, may be followed by TH or TC, may be followed by E2 or P2, may be followed by RP60U, may be followed by G1, G, Y or TS, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by RP60U, may be followed by G1, G, Y or TS, followed by LE, may be folowed by 2 or 3, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12-##, GL##-##, GAL##- ##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed 55, may be followed by E2 or P2, may be followed by 139 to 145, RP4# or RP6#, followed by LE, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, followed by -AGJ### or -AK1EJ###, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) Limit swtiches Model(s) WL, may be followed by M, followed by RCA2-, CA2-##, CA-##, CA12-##, CL##-##, CAL##-##, RG2-, G2-##, G12- ##, GL##-##, GAL##-##, RCA2-2, CA2-2##, CA-2##, CA12-2##, CL##-2##, CAL##-2##, RCA2-2N, CA2-2##N, CA-2##N, CA12-2##N, CL##-2##N or, CAL##-2##N, RGCA-, GCA2-##, GCA12-##, GCL##-##, GCAL##-##, RCA32-, CA32-###, D###-, D2###-, D3###-, SD###-, SD2###-, SD3###-, NJ-###, NJ-S### or GNJ-###, may be followed by P1, TH or TC55, may be followed by E2 or P2, may be followed by RP60U, may be followed by G1, G, Y or TS, followed by LD or LR, may be followed by 2 or 3, may be followed by A or F, may be followed by S or S2, may be followed by -Q, followed by -N, may be followed by optional letter(s) and/or number(s). ($) Pilot Light Model(s) Series M22N, followed by BN, BP, BG or BC, followed by TR, TG, TY, TW, TA, Or TO, followed by A, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E, followed by P or blank Pilot Lights Model(s) Series M30N, followed by MN, MP, MG, or MC, followed by TR, TG, TY, TW, TA, Or TO, followed by A, followed by R, G, Y, W, A, or O, followed by A, B, C, D, or E, followed by P or blank. Pushbutton Switch Model(s) Series A22N, followed by N, followed by BN, BP, BG, BM, MN, MP, MG, MM, RN, RP, or RM, followed by A or M, followed by NR, NG, NY, NW, NA, NB, UR, UG, UY, UW, UA or UO, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Pushbuttons Switches Model(s) Series A30N, followed by N, followed by MN, MP, MG, or MM, followed by A or M, followed by NR, NG, NY, NW, NA, NB, UR, UG, UY, UW, UA or UO, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Selector Switches Model(s) Series A22N, followed by S, followed by 2B, 2M, 2R, 3B, 3M, or 3R, followed by M, L, R, or B, followed by NR, NG, NY, NW, NA, or NB, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Series A30N, followed by S, followed by 2M or 3M, followed by M, L, R, or B, followed by NR, NG, NY, NW, NA, or NB, followed by A, followed by G or P, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by 0,1,2,A,B or C, followed by N, followed by N. Switch Contact Block Model(s) Series A22N followed by Z, followed by S, followed by G or P, followed by 1 or 2, followed by A,B or C, followed by blank or N. Investigated to CAN/CSA C22.2. No Auxilary Device Enclosed Model(s) Switches, type D4SL-N; followed by 1, 2, 3 or 4; followed by A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q or R; followed by F or D; followed by A or G; may be followed by C or D; may be followed by 4; followed by C; followed by 1, 3 or 5 may be followed by additional letter(s) and/or number(s). Door lock switches Model(s) D4GL, followed by 1, 2, 3 or 4, followed by A thru H or J thru M, followed by B, F, L, R, D, E, G or H, followed by A, G or N, may be followed by A, B or C, may be followed by 4, may be followed by N.* Door switches Model(s) D4BL Series, followed by 1, 2, 3 or 4, followed by C, D, E or F, followed by A, B C, D, E, F or G, followed by blank, A, B, C, D, E or F, followed by blank, or T, followed by blank or up to six letters and/or numbers. D4BS-11BSF1*, D4BS-11FSF1*, D4BS-11LSF1*, D4BS-11RSF1*