Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.
|
|
- Alan Barker
- 6 years ago
- Views:
Transcription
1 Solenoid s Inline s IV Nominal diameter 3 mm Suitability for Industry-Specific Applications Applications Inline valve for deactivation of unused suction pads Individual control of the suction pads of a "vacuum carpet", e.g. when picking items from stock System monitoring in vacuum spiders by active activation and deactivation of suction pads Inline valves IV Design Attachment facility for vacuum sensor External body made of aluminum (2) Integrated filter (3) for ventilation 4-pin M8 connector (1) Nominal diameter 3 mm; nominal flow rate 2 m³/h System design inline valves IV Suction pads with inline valves IV being used for handling car bodywork parts Our Highlights... Direct mounting in a suction pad Compact construction, simple installation Integrated filter screen to protect against dirt Decentralized vacuum control and system monitoring with a valve and an optional Mini- Sensor Your Benefits... > Individual control of single suction pads > Minimum space requirements; simple installation > Increased functional safety > Improved process reliability and reduced standstill times of vacuum systems Contact Services Gripping 519
2 Solenoid s Inline s IV Nominal diameter 3 mm Designation Code Inline s IV Abbreviated designation Nominal size in mm Version connection Suction pad connection Voltage in V Example IV 3 3/2 G3/8-IG G3/8-AG 24V-DC: IV 3 3/2 G3/8-IG G3/8-AG 24V-DC IV 3 3/2 3/2-way valve Ordering Data Inline s IV Inline valve IV is delivered as a ready to connect product (without connection cable). Available accessories: connection cable, vacuum sensors G3/8-IG (IG = female (F)) G1/4-IG G3/8-AG (AG = male (M)) 24V-DC Contact Services Gripping Inline s IV Part Number IV 3 3/2 G3/8-IG G3/8-AG 24V-DC IV 3 3/2 G1/4-IG G3/8-AG 24V-DC Ordering Data Accessories Inline s IV Connection cable, 5 m, M8 Connection cable, 5 m, M8 sensors analogue sensors digital straight 90 VS-V SA M5* VS-V SD 60 M5* IV3 G3/8-IG G3/8-AG 24V-DC IV3 G1/4-IG G3/8-AG 24V-DC *See section " system monitoring" for further details Technical Data Inline s IV Nominal size [mm] Principle of operation Voltage Nominal flow rate [m³/h] Nominal flow rate [l/min] Power consumption DC [W] Weight [kg] IV 3 3/2 G3/8-IG G3/8-AG 24V-DC 3 Normally open 24V - DC IV 3 3/2 G1/4-IG G3/8-AG 24V-DC 3 Normally open 24V - DC
3 Solenoid s Inline s IV Nominal diameter 3 mm Design Data and Functional Circuit Diagramm Inline s IV Contact Services Gripping IV 3 Circuit diagram IV 3 (1 = vacuum generator; 2 = suction pad) Dimensions in mm G1 G2 G3 G4 H LG1 LG2 LG3 SW1 IV 3 3/2 G3/8-IG G3/8-AG 24V-DC G3/8"-F G3/8"-M M8-M M5-F IV 3 3/2 G1/4-IG G3/8-AG 24V-DC G1/4"-F G3/8"-M M8-M M5-F
4 Solenoid s Solenoid s EMV Nominal diameter from 2 mm to 25 mm Suitability for Industry-Specific Applications Applications Control of vacuum, blow-off and venting of the suction pad Control of compressed air or vacuum in lines with smaller crosssections NO function ensures workpiece is held even in the case of a power failure For handling tasks with short switching times Suitable for neutral or filtered air Solenoid valves EMV Design Our Highlights... Your Benefits... Directly controlled solenoid valve EMV 2 and EMV 3 always with NC switching function Degree of protection IP 65 Connection socket complies with DIN , Form A Supplied complete with plug connector and (for DC operation) a quenching diode Designation Code Solenoid s EMV Seat valve in robust metal housing Directly controlled 3/2-way valve (exception: EMV 3 is a 2/2-way valve) Switching function NO (exception: EMV 2 and EMV 3 are NC) > Suitable for vacuum and compressed air > Short opening and closing times > Control of on/off and venting functions > Safety in the case of a power failure Contact Services Gripping Abbreviated designation Nominal size in mm Voltage in V Version Idle position suction valve Example EMV 5 24V-DC 3/2 NO: EMV 5 24V-DC 3/2 NO EMV 2 24V-DC direct current 3/2 3/2-way-valve NC normally closed V-AC single-phase NO normally open Ordering Data Solenoid s EMV Solenoid valve EMV is delivered as a ready to connect product. Available accessories: venting filter 522
5 Solenoid s Solenoid s EMV Nominal diameter from 2 mm to 25 mm Solenoid s EMV Operating voltage 230V-AC 24V-DC EMV EMV EMV EMV EMV EMV EMV Ordering Accessories Data Solenoid s EMV Venting filter with mounting kit EMV 2 - EMV 3 - EMV EMV EMV EMV EMV Contact Services Gripping Technical Data Solenoid s EMV Nominal size Principle of operation Nominal flow Nominal flow Power consumption DC Closing time Weight [kg] [mm] rate [m³/h] rate [l/min] [W] [ms] EMV 2 2 Normally closed EMV 3 3 Normally closed EMV 5 5 Normally open EMV Normally open EMV Normally open EMV Normally open EMV Normally open
6 Solenoid s Solenoid s EMV Nominal diameter from 2 mm to 25 mm Design Data Solenoid s EMV EMV 2 EMV 3 EMV 5 EMV 10 Contact Services Gripping EMV
7 Solenoid s Solenoid s EMV Nominal diameter from 2 mm to 25 mm Design Data Solenoid s EMV Dimensions in mm B B1 B2 d D G1 G2 G3 G5 H H1 L L1 LG1 LG5 X1 Y1 EMV G1/8"-F G1/8"-F - M5-F EMV G1/4"-F - - M3-F EMV G1/4"-F G1/4"-F G1/4"-F M4-F EMV G1/2"-F G1/2"-F G1/2"-F EMV G3/4"-F G3/4"-F G3/4"-F EMV G1"-F G1"-F G1"-F EMV G1-1/4"-F G1-1/4"-F G1-1/4"-F Functional Circuit Diagram Solenoid s EMV Circuit diagram EMV 3 (1 = vacuum generator; 2 = suction pad) Circuit diagram EMV 2, EMV 5 (1 = vacuum generator; 2 = suction pad; 3 = ventilation) Circuit diagram EMV (1 = vacuum generator; 2 = suction pad; 3 = ventilation) Contact Services Gripping 525
8 Solenoid s Solenoid s EMVO Nominal diameter from 12 mm to 25 mm Suitability for Industry-Specific Applications Applications Solenoid valve for use at high volume flow rates in systems with large cross-sections Control of vacuum, blow-off and venting of the suction pad Suitable for neutral or filtered air Solenoid valves EMVO Design Our Highlights... Your Benefits... Directly controlled solenoid valve Switching function (NC) Seat valve in housing made of brass and aluminum Degree of protection IP 65 Connection socket complies with DIN , Form A Supplied complete with plug connector 3/2-way valve with large nominal diameter Directly controlled > Control of vacuum on/off or venting function > Suitable for lines with large nominal flow rates > Short opening and closing times Contact Services Gripping Designation Code Solenoid s EMVO Abbreviated designation Nominal size in mm Voltage in V Version Idle position suction valve Example EMVO V-AC 3/2 NC: EMVO V-AC 3/2 NC EMVO 12 24V-DC direct current 3/2 3/2-way-valve NC normally closed V-AC single-phase NO normally open Ordering Data Solenoid s EMVO Solenoid valve EMVO is delivered as a ready to connect product. Available accessories: venting filter 526
9 Solenoid s Solenoid s EMVO Nominal diameter from 12 mm to 25 mm Solenoid s EMVO Operating voltage 230V-AC 24V-DC EMVO EMVO EMVO Ordering Data Accessories Solenoid s EMVO Venting filter with mounting kit EMVO EMVO EMVO Technical Data Solenoid s EMVO Nominal size [mm] Principle of operation Nominal flow rate [m³/h] Nominal flow rate [l/min] Power consumption DC [W] Power consumption AC3 [W] Weight [kg] EMVO Normally closed EMVO Normally closed EMVO Normally closed Design Data and Functional Circuit Diagram Solenoid s EMVO EMVO 12 to 25 Circuit diagram EMVO (1 = vacuum generator; 2 = suction pad; 3 = ventilation) Dimensions in mm d D G1 G2 G3 H H1 H3 L L2 X1 Y1 EMVO G1/2"-F G1/2"-F G1/2"-F EMVO G3/4"-F G3/4"-F G3/4"-F EMVO G1"-F G1"-F G1"-F Contact Services Gripping 527
10 Solenoid s Solenoid s EMVP Nominal diameter from 5 mm to 50 mm Suitability for Industry-Specific Applications Applications Solenoid valve for control at high nominal flow rates Control of vacuum, blow-off and venting of the suction pad NO function ensures the workpiece is held even in the case of a power failure For handling tasks with very short switching times Suitable for neutral or filtered gases Solenoid valves EMVP Design Our Highlights... Your Benefits... Solenoid valve with pneumatic pilot control Seat valve in aluminum housing (EMVP 5, EMVP 8) as well as plastic housing EMVP 10 to 50 Degree of protection IP 65 according to EN Connection socket (EMVP 10-50) complies with DIN , Form A Supplied complete with plug connector and (for DC operation) a quenching diode Designation Code Solenoid s EMVP Pilot control with compressed air (p = 5 bar) Wide range of nominal diameters 3/2-way valve Bistable impulse valve > Extremely short opening and closing times > Also suitable for high volume flow rates > Control of vacuum on/off or venting functions > Prevention of air consuption in case of power failures Contact Services Gripping Abbreviated designation Nominal size in mm Voltage in V Version Idle position suction valve Example EMVP 15 24V-DC 3/2 NC: EMVP 15 24V-DC 3/2 NC EMVP 5 24V-DC direct current 3/2 3/2-way-valve IMP bistable, switched 8 230V-AC single-phase 5/2 5/2-way-valve with pulse 10 NC normally closed NO normally open Ordering Data Solenoid s EMVP Solenoid valve EMVP is delivered as a ready to connect product. Available accessories: venting filter, connection cable for solenoid valves, socket with M12-connection 528
11 Solenoid s Solenoid s EMVP Nominal diameter from 5 mm to 50 mm Solenoid s EMVP Part Number EMVP 5 24V-DC 3/2 NC EMVP 5 24V-DC 5/2 IMP EMVP 8 24V-DC 3/2 NC EMVP 8 24V-DC 5/2 IMP EMVP V-AC 3/2 NO EMVP 10 24V-DC 3/2 NO EMVP V-AC 3/2 NO/NC EMVP 15 24V-DC 3/2 NO/NC EMVP 15 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 20 24V-DC 3/2 NO/NC EMVP 20 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 25 24V-DC 3/2 NO/NC EMVP 25 24V-DC 3/2 IMP EMVP V-AC 3/2 NO EMVP 32 24V-DC 3/2 NO EMVP V-AC 3/2 NO EMVP 50 24V-DC 3/2 NO Ordering Data Accessories Solenoid s EMVP Venting filter with mounting kit Connection cable for solenoid Socket with M12-connection valves (3 m, PUR) EMVP 5 24V-DC 3/2 NC EMVP 5 24V-DC 5/2 IMP EMVP 8 24V-DC 3/2 NC EMVP 8 24V-DC 5/2 IMP EMVP V-AC 3/2 NO EMVP 10 24V-DC 3/2 NO EMVP V-AC 3/2 NO/NC EMVP 15 24V-DC 3/2 NO/NC EMVP 15 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 20 24V-DC 3/2 NO/NC EMVP 20 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 25 24V-DC 3/2 NO/NC EMVP 25 24V-DC 3/2 IMP EMVP V-AC 3/2 NO EMVP 32 24V-DC 3/2 NO EMVP V-AC 3/2 NO EMVP 50 24V-DC 3/2 NO Contact Services Gripping 529
12 Solenoid s Solenoid s EMVP Nominal diameter from 5 mm to 50 mm Technical Data Solenoid s EMVP Nominal size [mm] Principle of operation Nominal flow rate [m³/h] Nominal flow rate [l/min] Power consumption DC [W] Closing time [ms] Weight [kg] EMVP 5 24V-DC 3/2 NC 5 Normally closed EMVP 5 24V-DC 5/2 IMP 5 Double pilot valve EMVP 8 24V-DC 3/2 NC 8 Normally closed EMVP 8 24V-DC 5/2 IMP 8 Double pilot valve EMVP V-AC 3/2 NO 10 Normally open EMVP 10 24V-DC 3/2 NO 10 Normally open EMVP V-AC 3/2 NO/NC 15 Optionally NO/NC EMVP 15 24V-DC 3/2 NO/NC 15 Optionally NO/NC EMVP 15 24V-DC 3/2 IMP 15 Double pilot valve EMVP V-AC 3/2 NO/NC 20 Optionally NO/NC EMVP 20 24V-DC 3/2 NO/NC 20 Optionally NO/NC EMVP 20 24V-DC 3/2 IMP 20 Double pilot valve EMVP V-AC 3/2 NO/NC 25 Optionally NO/NC EMVP 25 24V-DC 3/2 NO/NC 25 Optionally NO/NC EMVP 25 24V-DC 3/2 IMP 25 Double pilot valve EMVP V-AC 3/2 NO 32 Normally open EMVP 32 24V-DC 3/2 NO 32 Normally open EMVP V-AC 3/2 NO 50 Normally open EMVP 50 24V-DC 3/2 NO 50 Normally open Design Data Solenoid s EMVP Contact Services Gripping EMVP 5/8...NC EMVP 5/8...IMP 530
13 Solenoid s Solenoid s EMVP Nominal diameter from 5 mm to 50 mm Design Data Solenoid s EMVP EMVP 10 EMVP 15/20/25...NO/NC EMVP 15/20/25...IMP EMVP 32/50 Dimensions in mm B B1 B2 d D G1 G2 G3 G4 EMVP 5 24V-DC 3/2 NC G1/8"-F G1/8"-F G1/8"-F - EMVP 5 24V-DC 5/2 IMP G1/8"-F G1/8"-F G1/8"-F - EMVP 8 24V-DC 3/2 NC G1/4"-F G1/4"-F G1/4"-F - EMVP 8 24V-DC 5/2 IMP G1/4"-F G1/4"-F G1/4"-F - EMVP V-AC 3/2 NO G3/8"-F G3/8"-F G3/8"-F G1/8"-F EMVP 10 24V-DC 3/2 NO G3/8"-F G3/8"-F G3/8"-F G1/8"-F EMVP V-AC 3/2 NO/NC G1/2"-F G1/2"-F G1/2"-F G1/8"-F EMVP 15 24V-DC 3/2 NO/NC G1/2"-F G1/2"-F G1/2"-F G1/8"-F EMVP 15 24V-DC 3/2 IMP G1/2"-F G1/2"-F G1/2"-F G1/8"-F EMVP V-AC 3/2 NO/NC G3/4"-F G3/4"-F G3/4"-F G1/8"-F EMVP 20 24V-DC 3/2 NO/NC G3/4"-F G3/4"-F G3/4"-F G1/8"-F EMVP 20 24V-DC 3/2 IMP G3/4"-F G3/4"-F G3/4"-F G1/8"-F EMVP V-AC 3/2 NO/NC G1"-F G1"-F G1"-F G1/8"-F EMVP 25 24V-DC 3/2 NO/NC G1"-F G1"-F G1"-F G1/8"-F EMVP 25 24V-DC 3/2 IMP G1"-F G1"-F G1"-F G1/8"-F EMVP V-AC 3/2 NO G1-1/4"-F G1-1/4"-F G3/4"-F G1/8"-F EMVP 32 24V-DC 3/2 NO G1-1/4"-F G1-1/4"-F G3/4"-F G1/8"-F EMVP V-AC 3/2 NO G2"-F G2"-F G1-1/4"-F G1/8"-F EMVP 50 24V-DC 3/2 NO G2"-F G2"-F G1-1/4"-F G1/8"-F Contact Services Gripping
14 Solenoid s Solenoid s EMVP Nominal diameter from 5 mm to 50 mm Design Data Solenoid s EMVP Dimensions in mm H H1 H2 H3 H4 L L1 X1 Y1 EMVP 5 24V-DC 3/2 NC EMVP 5 24V-DC 5/2 IMP EMVP 8 24V-DC 3/2 NC EMVP 8 24V-DC 5/2 IMP EMVP V-AC 3/2 NO EMVP 10 24V-DC 3/2 NO EMVP V-AC 3/2 NO/NC EMVP 15 24V-DC 3/2 NO/NC EMVP 15 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 20 24V-DC 3/2 NO/NC EMVP 20 24V-DC 3/2 IMP EMVP V-AC 3/2 NO/NC EMVP 25 24V-DC 3/2 NO/NC EMVP 25 24V-DC 3/2 IMP EMVP V-AC 3/2 NO EMVP 32 24V-DC 3/2 NO EMVP V-AC 3/2 NO EMVP 50 24V-DC 3/2 NO Functional Circuit Diagram Solenoid s EMVP Contact Services Gripping Circuit diagram EMVP 5 and EMVP 8 (1 = vacuum generator; 2 = suction pad; 3 = ventilation) Circuit diagram EMVP 10 to 50 NO/NC (1 = vacuum generator; 2 = suction pad; 3 = ventilation) 532
3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional
Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationSolenoid valves VZWD, directly actuated
2015/12 Subject to change Internet: www.festo.com/catalogue/... 1 Key features and overview General Directly actuated solenoid valves VZWD are mainly intended for applications with high pressure ranges
More informationSolenoid valves VZWD, directly actuated
q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationEasy programming Robust. Flexible. FPS Flexible Position Sensor FPS. Field of Application. Advantages Your benefit. Options and special Information
FPS Easy programming Robust. Flexible. FPS Flexible Position Sensor The FPS sensor system determines the position of the base jaws. Then it digitally shows, in which of the five freely teachable ranges
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationRCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)
RCA PLUGS & JACKS 24-100-0 Bulk 24-100-2 Pkg (2) Metal body RCA plug. Maximum cable dia. 7.5mm 24-104-0 Bulk 24-104-2 Pkg (2) Metal plug with strain relief. Maximum cable dia. 4.5mm Use 84-156-1 tool for
More informationCatalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:
2013 Catalogue BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) 473-0026 FAX. (+36-1)473-0027 e-mail: logen@logen.hu Web: http://www.logen.hu DIGITAL DIMMER LDD1225-C2 2500 Watt Per Channels DMX 512 Control Each
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationV 180 Series Photoelectric Switches
D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal
More informationW100L: Laser Sensor in Mini- Format
Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can
More informationLinear encoders without bearings incremental System for linear motion feedback
Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system
More informationGear Pump Units. For single-line lubrication systems
Gear Pump Units 1-1202-US For single-line lubrication systems MFE5-KW3-2 MFE5-BW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationPulse Counters, electromechanical
Mini Counters W 5 / AW 5 5-digit miniature pulse counter, adding with manual reset Power consumption min. 30 mw Suitable for battery and electronic switching operations Long operating life (50 Mio. pulses)
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationPressure sensors with display
412 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 sensors P sensors PK series series Multifaceted pneumatic specialists The PK pressure sensors are especially designed for pneumatic
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationCatalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:
2016 Catalogue BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) 473-0026 FAX. (+36-1)473-0027 e-mail: logen@logen.hu Web: http://www.logen.hu DIGITAL DIMMER LDD1225-C2 2500 Watt Per Channels DMX 512 Control Each
More informationConnecting cables for valves, round plug connectors Product range overview
Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationUp to 85% higher Service Life due to efficient sealing method.
Robot Accessories Feeding through Up to 85% higher Service Life due to efficient sealing method. 346 Robot Accessories Feeding through Feeding through DDF 2 Rotary Feed-through Series Size Page DDF 2 348
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationFLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids
Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering.
More informationWelding equipment for the POLYSTIC system
L Welding equipment for the POLYSTIC system TITGEMEYER Tb1435GB(0110)2 Installation tools 355 Stud-welding machine TSG 60 for drawn-arc stud welding process The compactly-designed TSG 60 combines operating
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationFlexibility and Safety. BERNSTEIN safety hinge switches
Flexibility and Safety BERNSTEIN safety hinge switches BERNSTEIN safety hinge switches Advantages of safety hinge switches in comparison to traditional door contacts Easy to install and tamper-resistant
More informationHIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology
H I G H V A C U U M P U M P S Adixen by Alcatel Vacuum Technology Hybrid Turbomolecular Pumps 139 Introduction Alcatel offers the of hybrid turbomolecular pumps with pumping speeds ranging from 30 to 300
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationDigital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.
3-Color Display New F type Rated distance range.1 to.3 mm (Displayable/Settable range: to 6) Digital Gap Checker G type Rated distance range.2 to.15 mm (Displayable/Settable range: 1 to 3) H type Rated
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationLUT Luminescence scanners: Seeing what no-one else can
LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.
More informationNational Wire and Cable and National Cable Molding Headquarters Los Angeles California
National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationT L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.
T L Audio User Manual C1 VALVE COMPRESSOR Tony Larking Professional Sales Limited, Letchworth, England. Tel: 01462 490600. International +44 1462 490600. Fax: 01462 490700. International +44 1462 490700.
More informationDIN Connectors DIN06 E-03
DIN Connectors DIN0 E-0 Contents Introduction HOSIDEN DIN connectors are supplied to electronic equipment manufacturers both in Japan and overseas and are very well accepted because of high quality, a
More informationConnecting cables NEBS, for sensors
Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic
More informationFlexible. Fast. Precise. PPU-E Pick & Place Unit
PPU-E Flexible. Fast. Precise. PPU-E Pick & Place Unit Compact 2-axis unit for a faster, flexible running of any curve on one plane. Field of Application For use in clean and slightly polluted environment.
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationPEGAS 160 T PULSE HF PEGAS 200 T PULSE HF
- 1 - WELDING INVERTER PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF OPERATING MANUAL PEGAS 160-200 T PULSE manual EN 06 -2- CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationTHE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS
FOCUS ON FINE SOLUTIONS THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS Welding lasers from ROFIN ROFIN s laser sources for welding satisfy all criteria for the optimized laser
More informationSentinel I24 Digital Input and Output Configuration
Application Bulletin: #155 Date: October 19, 2007 Sentinel I24 Digital Input and Output Configuration The Sentinel I24 can communicate with external hardware using digital inputs and outputs. There are
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationDigital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.
3-Color Display F type Rated distance range.1 to.3 mm (Displayable/Settable range: to 6) Digital Gap Checker G type Rated distance range.2 to.15 mm (Displayable/Settable range: 1 to 3) H type Rated distance
More informationLINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56
LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for
More informationConnecting cables for valves, Sub-D Type codes
Type codes NEBV C S1 G 44 K Function NEBV Connecting cables for valves Product design Standard C Easy to clean design Connection technology, left, field device side S1 S7 Sub-D socket Sub-D HD socket Cable
More informationUser Manual RTHDBT402PT & RTHDBT402PR
User Manual RTHDBT402PT & RTHDBT402PR REVTEK HDMI/IR/RS232 Twisted Pair Extender HDBaseT with POE Page 1 All Rights Reserved Version: RTHDBT402P 2013V1.0 NOTICE: Please read this user manual carefully
More informationConnecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More information2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR
2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (i.e. 19 rack, 3U power supply), good
More informationSetting up the Setting up the Dragonfly 1 v June
Setting up the 1 Introduction In this guide we'll be setting up a rather complete observatory, integrating in the Dragonfly all relevant elements: Roof, motorized with a garage-door system and including
More informationHiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F
HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F Similar Image Rugged, powerful turbopump with a pumping speed of up to 260 l/s
More informationCatalog. Industrial Plugs & Sockets The complete range
Catalog Industrial Plugs & Sockets The complete range Contents Type Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs Splashproof...
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationAP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display
AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest
More informationCapacitive sensor BCT5-S18-UP6X2T-H1151
M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product
More informationLiner Quattro AC XB RGBW
Date: Quantity: Company: Project: Liner Quattro AC XB RGBW The Liner Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More information03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through
Feed-through Feed-through FEED-THROUGH Series Size Page Rotary Feed-through for Robots DDF 202 DDF 031 206 DDF 040 208 DDF 040-1 210 DDF 050 212 DDF 050-1 214 DDF 063 216 DDF 080 218 DDF 080-1 220 DDF
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationHinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA
Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre
More informationultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs
18, 30 1 design M18x1 M30x1.5 dif. reflection sensor sensing range (teachable) 30... 400mm 60... 500mm 100... 800mm 80... 1500mm 200... 2000mm 300... 3500mm PBT plastic sleeve devices with thread to EURONORM
More informationFlow Sensor SFAB. 1.2 Characteristics Feature Order code Design. Festo AG & Co. KG. Postfach D Esslingen ++49/711/
Flow Sensor SFAB Festo AG & Co. KG Operating instructions 826 22a Original: de Postfach D-73726 Esslingen ++49/7/347- www.festo.com Installation and commissioning may only be performed in accordance with
More informationSPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment
2004 Specifications CSJ 0922-00-025, 0921-02-173 & 0921-06-208 SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment 1. Description. Furnish and install closed circuit television (CCTV) central equipment
More informationCOILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.
COUPLING TABLE COILS/ELECTOPILOTS ELECTOPILOTS/SOLENOID VALVES Electropilots A B AA(U1) AA(U3) AB (U2) Coils U04 U05 U1 U2 U3 10 mm 15 mm 22 mm 30 mm 30 mm BE AE BD ACN CL CM ISO 1 ISO 2 ISO 3 ISO 4 ISO
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationwith additional normally-open signalling contact l With integrated AS interface Safety at Work.
Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationPLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.
Features The AVG-HD400 is an HDBT 2.0 transceiver set which contains a transmitter and a receiver. Compliant with HDMI 1.4 & HDCP 2.2, it is able to transmit high-definition signals up to 4Kx2K@60Hz. The
More informationRCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS
RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationSensor technologies Proximity sensors Series ST4. Brochure
Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with
More informationATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar
0D (Pneumatic) Electronic pressure switch -... 0 bar, -... bar, 0... 6 bar, 0... 0 bar, 0... bar Fast error detection viamulti-colour display Easy to use pressure switch with clear display and intuitive
More informationL5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2
L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2 A. General 1. The luminaire shall be a RGBW color mixing LED Fresnel luminaire with an electronically controlled LED light
More informationMetric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable
More informationAMU1-BHD+ Audio monitoring Unit
AMU1-BHD+ Audio monitoring Unit Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AMU1-BHD+-6 1 ISSUE 6 SAFETY Installation. Unless otherwise
More informationDigital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3
3-Color Display Digital Gap Checker A 2 outputs type has been added. RoHS Check at a glance if the workpiece is placed or not! : Placed Workpiece Main screen OFF: Not placed Workpiece The clearance distance
More informationOperating Instructions
CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target
More informationCOLOR POWER SERIES DA CL9 VEGA
Technical Information We offer you many solutions to let your dreams come true. Color Power Line 9 is a product producing a light with high brightness in single color or color changing RBG to give the
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationTWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments
Dual line system Designed to work all the day, every day in extreme condition and difficult environments CONTENTS Applications 3 Description 4 Operation 5 Benefits 6 TWIN pump 7 TWIN measures 8 TWIN-PUMP
More informationDisplacement Measuring System for Cylinder Series OSP-P
-SENSOFLEX Displacement for Cylinder Series OSP-P Overview...112 Technical Data SFI-plus...113 Dimensions SFI-plus...114 Order Information...115 111 Sensoflex - Sensoflex Displacement measuring system
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More informationIONIVAC Transmitter ITR 90
IONIVAC Transmitter ITR 90 The ITR 90 is a optimized combination transmitter The combination of a hot cathode ionisation sensor according to Bayard-Alpert and a Pirani sensor permits vacuum pressure measurements
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More information