1 71346 LED Floodlight RoHS OVERALL LAMP PARAMETERS LED DRIVER LED Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage Output Current Driver Efficiency LED Manufacturer LED Type LED Quantity LED Efficacy Color Temperature Photocell - Lifespan Warranty LIFESPAN & IP Rating ENVIRONMENT Operating Temperature Storage Temperature.Humidity Safety Norms Withstand Voltage SAFETY&EMC Grounding Resistance Electromagnetic Compatibility Dimension Net Weight Packing Size OTHERS Q'ty / Carton Volume VAC 50/60HZ 0.38 AMax 49 W PF LM 88 LM/W Aluminium + Tempered Glass 23-42VDC 1.2A 89% cree CXA PCS 110 LM/W WW/NW/CW (5050K) Sold Separately 50000Hrs. 5 Years IP65 Wet Locations , 10 90% RH UL1598,UL8750, EN60598, EN , EN62031, EN62471 I/P-FG: 2121VDC 0.5Ω,OK EN55015, EN , EN , EN61547 Pls refer to attached diamension drawing 7.81 lbs inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS 1.65Cbm/carton

2 Dimension: 71346

3 LM Test Report For Architectural Flood and Spot Luminaires Model name(s): Representative (Tested) Model: Model Difference: All construction and rating are the same, except CCT Test & Report By: Sean Zhuo Engineer: Sean Zhuo Date: Jul.29,2014 Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 18

4 U.S. Department of Energy Lighting Facts TM Uniform LM-79 Reporting Template Laboratory Information: Name of Test Laboratory Standard-Tech Co. Ltd Date of Test Report Jul.29,2014 Test Report No. GZE L Laboratory Contact Name Tommy Liang Product Information: Organization Name Brand Name Model Number SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Architectural Flood and Spot Luminaires Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Electrical Measurements: Integrating Sphere Output Goniophotometer Output Input Wattage W Input Current A Input Voltage (ac) V Power Factor Off-State Power 0 -- W Photometric Characteristics Total Initial Lumen Output lm Initial Lumen Efficacy lm/w Correlated color temperature / CCT K Color rendering index / CRI R9 Value Duv Luminous Intensity Distribution Center beam candlepower (if applicable) -- Beam angle (if applicable) -- Zonal lumens in the 0-60 zone Zonal lumens in the zone -- Zonal lumens in the zone -- Zonal lumens in the zone -- 3 / 18

5 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction : Jul.28,2014 : Jul.29,2014 : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters IES LM Electrical and Photometric Measurements of Solid-State Lighting Products ANSI C Specifications for the Chromaticity of Solid State Lighting Products CIE Method of Measuring and Specifying Colour Rendering Properties of Light Sources CIE Technical Report Colorimetry IESNA LM Practical Guide to Colorimetry of Light Source IESNA TM Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD25 Test Methods 1. Photometric and Electrical measurements Light Distribution Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2. Photometric and Electrical Measurements Integrating Sphere Method: Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm. 4 / 18

6 Report No.: GZE L 1. Product Information: MORRIS Brand Name Model Number Luminaire Type Architectural Flood and Spot Luminaires Rated Voltage / Frequency 100 ~ 277 Vac, 50/60 Hz Nominal Power 50W Rated Initial Lamp Lumen -- Declared CCT 3000K,3500K,4000K,4500K,5000K LED Manufacturer CREE LED Model CXA1512 Sample Receipt Date Jul.28,2014 Sample Number (3000K),32 (5000K) Photo Address 8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou , China Tel: Fax: / 18

7 2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) IES LM Test date Test Ambient: 25.2 º C Test Orientation Lighting Downward, light surface Stabilization Time parallel to horizontal line (min) 90 Model Number Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) R1 81 R9 11 Frequency (Hz) 60 R2 88 R10 73 Color Rendering Index (CRI) 82.7 R3 95 R11 82 R9 11 R4 82 R12 68 CCT (K) 3151 R5 81 R13 82 Chromaticity (x, y) x= y= R6 85 R14 97 Chromaticity (u, v ) u'= v'= R7 86 R15 74 Duv R Goniophotometer Method: Parameter Result Test Voltage (V) Frequency (Hz) 60 Total Luminous (lm) Luminous Efficacy (lm/w) Beam Angle Center Beam Candle Power (cd) 1731 S/MH(C0/180) 1.24 S/MH(C90/270) / 18

8 Spectral Power Distribution Spectral Power Distribution: 7 / 18

9 Chromaticity Diagram 8 / 18

10 Zonal Lumen Tabulation Zonal Lumen Summary Zone Lumens % Lamp % Luminaire , % 34.2% , % 55.6% , % 94.3% % 5.5% % 0.6% % 0% , % 99.8% % 0.2% , % 100% Lumens Per Zone Zone Lumens % Total Zone Lumens % Total % % % % % % % % % % % % % % % % % % 9 / 18

11 Photometric Data Illuminance Plots 10 / 18

12 ISOCANDELA DIAGRAM ISOLUX DIAGRAM 11 / 18

13 Candela Table - Type C / 18

14 / 18

15 / 18

16 2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) IES LM Test date Test Ambient: 25.2 º C Test Orientation Lighting Downward, light surface Stabilization Time parallel to horizontal line (min) 90 Model Number Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) R1 81 R9 13 Frequency (Hz) 60 R2 88 R10 70 Color Rendering Index (CRI) 83.2 R3 92 R11 81 R9 13 R4 83 R12 61 CCT (K) 5050 R5 82 R13 83 Chromaticity (x, y) x= y= R6 83 R14 95 Chromaticity (u, v ) u'= v'= R7 88 R15 77 Duv R Total Luminous (lm) Luminous Efficacy (lm/w) / 18

17 Spectral Power Distribution Spectral Power Distribution: 16 / 18

18 Chromaticity Diagram 17 / 18

19 3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R meter Integrating Sphere ST-R-331 Spectral analysis system HAAS D204 Standard Lamp PF2010 Power Meter for Integrating Sphere EE-09 Goniophotometer system D908S Standard Lamp PF210 Power Meter for Goniophotometer ST-R-181A Temperature Tester ****** END OF DATASHEET PACKAGE ****** 18 / 18