LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
|
|
- Megan Young
- 5 years ago
- Views:
Transcription
1 LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from mbar up to bar ( mwc up to mwc) The screw-in transmitters LMP are suited for continuous level measurement of liquids in open tanks. They are used preferrably for level measurement in clean, thin fluid media. By the liquid column above the submersed transmitter a pressure is generated that is transmitted via a stainless steel diaphragm and inert oil filling onto the semiconductor sensor element. An amplifier circuit supplies the sensor and transforms the temperature compensated sensor output, which is proportional to the liquid level, into standard current and voltage output signals. The diaphragm is flush with a G/4 pressure port; an O-ring behind the thread provides sealing of the transmitter. A variety of standard output signals as well as mechanical and electrical connections make the LMP covering a wide field of applications. Additional it is possible to use the screw-in transmitter LMP in explosive area (zone 0). Preferred areas of use are: tank level measurement of neutral media water and sewage treatment plants Characteristics small thermal effect excellent linearity good long term stability option Ex-version (only for 4 0 ma / -wire) TÜV 0 ATEX 006 X accuracy: 0.75 / 0.5 / 0.05% FSO BFSL (0.5 / 0.5 / 0.% FSO IEC 60770) specific versions: - special pressure ranges LMP BD SENSORS GmbH BD-Sensors-Strasse Telefon +4 (0) 5 / D - 5 Thierstein Telefax +4 (0) 5 / 8 - info@bdsensors.de
2 LMP Input pressure range Nominal pressure gauge [bar] Level [mwc] Permissible overpressure [bar] Output signal / Supply Standard -wire: ma / V S =... 6 V DC Ex-protection: V S = V DC Optional -wire: ma / V S = V DC V / V S = V DC Performance Accuracy Permissible load standard: nominal pressure > 0.4 bar nominal pressure 0.4 bar option : nominal pressure > 0.4 bar option : nominal pressure 0.6 bar current -wire: R max = [(V S V S min ) / 0.0] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω IEC ± 0.5 % FSO ± 0.50 % FSO ± 0.5 % FSO ± 0.0 % FSO Influence effects Supply: 0.05 % FSO / 0 V Load: 0.05 % FSO / kω Long term stability Response time ± 0. % FSO / year < 5 msec. BFSL ± 0.75 % FSO ± 0.50 % FSO ± 0.5 % FSO ± % FSO Thermal errors (Offset and Span - standard) Nominal pressure gauge P N [bar] > Tolerance band [% FSO] ± ±.5 ± ± ± 0.75 TC, average [% FSO / 0 K] ± 0. ± 0. ± 0.4 ± 0. ± 0.07 in compensated range [ C] Thermal errors (Offset and Span - optional for C) Nominal pressure gauge P N [bar] >.0 Tolerance band [% FSO] ±.0 ±.5 ±.0 ± 0.75 TC, average [% FSO / 0 K] ± 0. ± 0. ± 0. ± 0.07 in compensated range [ C] Electrical protection Short-circuit protection Reverse polarity protection permanent no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Option Ex-protection only with ma / -wire DX-LMP zone 0 : II G EEx ia IIC T4 zone 0: II D T 85 C safety technical maximum values: V i = 8 V, I i = ma, P i = 660 mw; C i nf, L 0 µh i Permissible temperatures Medium C Electronics / environment C Ex-protection: application in zone 0: C application in zone or higher: C Storage C accuracy according to IEC limit point adjustment (non-linearity, hysteresis, repeatability) with optional accuracy 0. % FSO the response time is 00 msec approved for atmospheric pressure from 0.8 bar up to. bar pressure measurement
3 LMP Mechanical stability Vibration 0 g RMS ( Hz) Shock 00 g / msec Mechanical connection G/4 DIN 85 Total length of devices with Ex-protection increases by 6 mm! Total length of devices with accuracy 0. % FSO IEC increases by 4.5 mm! (standard and Ex-protection) Electrical connection Standard Optional DIN 4650 (IP 65) Binder Series 7 (IP 67) Mx 4-pin (IP 67) Cable gland (IP 67) 4, 5 Cable outlet (IP 68) 4 Buccaneer (IP 68) 6 4 different cable types and lengths available 5 standard: m PVC cable (without ventilation tube), optionally cable with ventilation tube 6 cable with ventilation tube required
4 LMP Materials Pressure port stainless steel.457 (6Ti) / others on request Housing stainless steel.40 (04) Seals (media wetted) FKM / EPDM / others on request Diaphragm stainless steel.445 (6L) Media wetted parts pressure port, seals, diaphragm Miscellaneous Cable capacitance 7 cable without air tube: signal line/shield: 60 pf/m signal line/signal line: 0 pf/m cable with air tube: signal line/shield: 50 pf/m signal line/signal line: 00 pf/m Cable inductance 7 cable without air tube: signal line/shield: 0.65 µh/m signal line/signal line: 0.65 µh/m cable with air tube: signal line/shield:.0 µh/m signal line/signal line:.0 µh/m Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight Installation position any 8 Operational life approx. 00 g > 00 x 0 6 cycles Pin configuration Electrical connection DIN 4650 Binder 7 (5-pin) -wire-system Supply + Supply 4 -wire-system Supply + Supply Signal + Wiring diagrams -wire-system (current) -wire-system (current) 7 if the electrical connection is a mounted cable by factory Mx (4-pin) Buccaneer (4-pin) Ground ground pin Ground ground pin wire-system (voltage) Cable colours 7 (DIN 4700) white brown yellow / green (shield) white brown green yellow / green (shield) This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. 8 Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges P N bar. LMP_E_0006 Telefon +4 (0) 5 / 8-0 Telefax +4 (0) 5 / info@bdsensors.de
5 Fax: +4 (0) 5 / 8 - Ordering code LMP LMP Pressure in bar in mwc Input [mwc] [bar] 0,4 0, ,6 0, , ,6 0, ,5 0, , , , , , , , Pressure port Stainless steal.457 (6Ti) Diaphragm Stainless steel.445 (6L) Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire Seals FKM EPDM Electrical connection Male and female plug DIN 4650 Binder series 7 (5-pin) Cable gland incl. Cable Cable outlet , T R 0 Male plug Buccaneer IP Mx (4-pin) M 0 0 Accuracy standard for P N > 0,4 bar 0,5 % standard for P N 0,4 bar 0,5 % 5 option for P N > 0,4 bar 0,5 % option for P N 0,6 bar 0, % Special version standard special compensation C different cable types and lengths deliverable standard: m PVC cable without ventilation tube for gauge pressure cable with ventilation tube required E BD SENSORS GmbH BD-Sensors-Straße Telefon +4 (0) 5 / D - 5 Thierstein Telefax +4 (0) 5 / 8 - info@bdsensors.de 0006 This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.
- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationLMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationDS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO
Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationTPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN
TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationRSCC. Load cells. Special features. Data sheet
RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationJUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationSignet 2250 Hydrostatic Level Sensor
Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationMetric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationContactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationContactless encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,
More informationContactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151
Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output
More informationMicro-Machined Silicon Transducers
Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationContactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationCapacitance Level Measurement Electronic insert FEC 12
Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation
More informationLinear encoders without bearings incremental System for linear motion feedback
Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationMG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV
MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationContactless encoder Ri360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. SSI output 25 bit, Gray-coded SSI clock rate: 62.5 KHz 1 MHz Single or multiturn,
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationEddy Current Probe System
CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used
More information2291 Guided Wave Radar Level Transmitter
2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationSensopress LCD Special English
Sensopress LCD Special English edition 2-09/2004 - code 5878 1/16 Sensopress LCD with sensor Power Supply Voltage 117 V~ 50 60 Hz 230V~ 50 60 Hz Code TSL00X0100 TSL00Y0100 Consumption 5,5 VA Display LCD
More informationContactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationData sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)
Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years, Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationDewatering. Series description Wilo-Drain STS 65. Submersible sewage pump
Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationProduct Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads
Product Information RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads May 2014 RIQ 425 Absolute rotary encoders Synchro flange 01C Solid shaft for separate shaft
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationPanel-mounting Thermostats EM Series
Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationPanel-Mounted Thermostat
Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief
More informationFlow Switch. Flow Switch
Flow Switch Flow Switch u Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer u Valves & Regulators u Temperature u Level u Flow u Air Suspension Valves Barksdale
More informationData sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)
Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Pump curves Wilo-Drain TP 65 E - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 15.0 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationInductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151
Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog
More information1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.
ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read
More information3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional
Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200
More informationSpeed sensor MiniCoder GEL 2471
Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless
More informationIndustriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500
Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More information