Control & Automation Overview. Behind every project, technologies and expertise. Timers. Control relays. Counters and Ratemeters

Size: px
Start display at page:

Download "Control & Automation Overview. Behind every project, technologies and expertise. Timers. Control relays. Counters and Ratemeters"

Transcription

1 Timers Control relays Counters and Ratemeters Temperature controllers Safety relays Logic controllers Control & Automation Overview Behind every project, technologies and expertise

2 Contents Crouzet Control Presentation P. 4 Expertise P. 6 P. 4-7 Timers The basics P. 10 Applications P. 12 Selection guide P. 14 Function diagrams P. 20 DIN rail mounted Panel mounted P Timers Control relays The basics P. 26 Applications P. 28 Selection guide P. 30 Modular casing Industrial casing P Control relays Counters and Ratemeters The basics P. 38 Applications P. 40 Selection guide P. 42 Connection diagrams P. 48 Electronic Electromechanical P Counters and Ratemeters Temperature controllers The basics P. 52 Applications P. 54 Selection guide P. 56 Digital Accessories P Temperature controllers Safety relays The basics P. 60 Selection guide P. 62 Applications P. 64 Relevelling control Machine safety P Safety relays Logic controllers The basics P. 66 Millenium 3 P. 69 The range P. 70 Accessories P. 71 Communication solutions P. 72 M3 Soft software P. 74 Function blocks P. 76 Applications P. 78 Selection guide P. 80 Millenium 3 Accessories P Logic controllers Part numbers index P To order: Customer Service Tel : info@crouzet.co.uk 2 I l Panorama Crouzet Control / Crouzet Automation 3

3 Presentation Widely recognised for over 50 years as the specialist in electromechanical, electronic technology and software engineering, Crouzet Control experience in time management, physical and mechanical values has resulted in an extensive automation components offer that includes logic controllers, timers, control relays, counters, ratemeters, machine safety equipment, and temperature controllers. Simple to use, Crouzet Control products are easy to program and install. With operations around the globe, Crouzet Control is constantly monitoring its customers' needs. Its sales teams, technicians and designers combine all their skills to adapt products to customer specifications, both in terms of the application and cost. Crouzet Control also ensures that its products are manufactured in compliance with quality and environmental standards (factories certified ISO 9001, and OHSAS 18001, eco-design). With its industrial and logistic flexibility Crouzet Control is able to deliver products, whether small-scale or mass production items, in the best possible timescale. Custom Sensors & Technologies (CST), is a specialist in sensing, control and motion products. Through its brands, BEI Kimco, BEI Sensors, BEI PSSC, Crouzet, Crydom, Kavlico, Newall and Systron Donner Inertial, CST offers customizable, reliable and efficient components for mission-critical systems in Aerospace & Defense, Transportation, Energy & Infrastructure, Medical, Food and Beverage and Building Equipment markets. Focused on premium value offers and committed to excellence, CST, with 4,400 employees worldwide and sales of $604M US in 2012, is the dependable and adaptable partner for the most demanding customers. In this new Panorama, Crouzet Control presents: A new range of redesigned Safety Relays for machine safety applications with new functions and easy installation. Crouzet Control / Crouzet Automation team worldwide. New Chronos 2 timers (17.5 mm) substituting the existing range with an improved electronic and mechanical design allowing added robustness and reliability. Crouzet Automation, supported by an experienced sales and technical team and an easy-touse software, is the adaptable alternative for any automation solution. Crouzet Automation is the perfect solution for any specialized or demanding need. These products are specifically suited for integration in a wide range of applications such as waste and water treatment, access control, renewable energies, building equipment, industrial machines and transportation. Production Sales subsidiaries 4 I l Panorama Crouzet Control / Crouzet Automation 5

4 Expertise The Crouzet Control process In addition to high-performance products, advice and support, Crouzet Control offers tailor-made solutions for any application. A multi-skilled team Application-based marketing Electronic and software design Prototyping Mechanical engineering Production EMC tests and approvals Sales and logistics follow-up Analysis of customer requirements Expertise: UNDERSTANDING how applications work. Specific products Standard products Production INTEGRATING environmental constraints and quality requirements. PROPOSING technical and economic solutions which fully meet the needs of customers. Adapted products Products with added value Expertise: MEETING all needs, standard or specific, small-scale or mass production, thanks to the industrial flexibility of Crouzet's factories. GUARANTEEING the quality and reliability of products: all Crouzet s production sites are certified ISO 9001 and ISO 14001, and use quality tools such as 6 SIGMA. INTEGRATING eco-design into manufacturing processes to MINIMIZE the environmental impact of products throughout their life cycle. Customer Adaptation Centre and Design Office Expertise: Logistics and After-Sales Service CAPITALISING on the expertise of Crouzet engineers in mechanical, electrical and electronic engineering, software engineering and networks. Expertise: PROVIDING an optimum level of service ADAPTING products to ensure innovation and differentiation. DEVELOPING AND INDUSTRIALIZING custom products. and GUARANTEEING a prompt delivery schedule, whatever the type of order: small-scale or mass production, standard or adapted products. TRACKING all orders in real time on 6 I l Panorama Crouzet Control / Crouzet Automation 7

5 Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the website offers the latest tools, available as free downloads, including, technical data sheets and installation manuals for each product. Timers Time management 8 I 9

6 The basics A timer How can it be defined in simple terms? A timer is a simple automation component which is used to manage actions over a period of time or control how long actions last.the timer is a control device which triggers an action according to a time and a function. After a predefined time has elapsed, the timer closes or opens one or more contacts. Timing cycles, whether single shot or repetitive, are started by latching inputs or pulsed inputs, allowing a wide variety of functions to be created. Crouzet Control, timers A panel mounted range and a DIN rail mounted range Timers Timing range 1 A timer To execute which actions? Triggering, Actuating A timer can be used to trigger an action according to a predefined time. It can also be used to stagger actions over a period of time. Delaying, Flashing In any time-related application, the timer can play a role and can be used to: Run installations according to times that can be adjusted by the user. Calibrate a machine running time. Allow or prevent an action. Delay an action. Manage stopping/starting of a motor, pump, etc. (star delta). Make an LED flash. Triggering Actuating Delaying Flashing In addition to this catalogue, the website offers technical data sheets and installation manuals for each product, available as free downloads. 815 timer Crouzet Control, timers Their features: Setpoint settings Mode Reset + enable Available in mono or multifunction versions (analogue or digital, with or without memory), to meet the specific needs of each application. A timing range of up to 9,999 hrs to cope with prolonged processing operations. MLR1 Time setting 1 Timing range 2 Time setting 2 Power supply LED A range of supply voltages from 12 to 240 V in one unit for optimised stocks. Recognised quality and reliability ensures the correct operation of equipment. 10 I l Panorama Crouzet Control 11

7 Applications Crouzet Control, timers Where are they found? Ice maker Managing the duration of refrigeration. Drink vending machine Timed management of delivery of drinks. In electrical cabinets associated with other automation functions for the following markets: Timers Food industry Industrial automation systems Lighting Building equipment HVAC Small or large industrial machines Timer TUR1, MUR1, MAR Timer TMR48, Timer 81x Packaging Controlling heat sealing times on blister packs, packaging bags, etc. Illuminated signs Managing flashing on illuminated signs. Lighting for mobile homes Managing the duration of outdoor lighting of a mobile home if the light switch is left switched on. Machine tools Control of maintenance periods. Timer MUR1, MXR1, mar1 Timer mlr timed impulse relay MXR Timer TMR48, Timer 81x Fan Time management for delayed fan start-up. Dosage Time management for distribution of glue, varnish... Sensing on assembly line Managing the operation of a conveyor belt based on the time interval between products on the belt. Remote machinery Managing maintenance of the power supply in the event of a mains power failure, switching on an external backup power source for a given time. Timer (TMR48, Timer 81x) timer MBR1 Timer MCR1 Timer TK2R1 12 I l Panorama Crouzet Control 13

8 Selection guide Chronos 2 DIN rail mounted, Timers DIN rail modular casings Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type A / At / B / C / H / Ht Di / D / Ac / Bw MUR Screw terminals A / At MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h MBR1 C MCR1 H / Ht MHR1 L / Li 12 V z MLR4 24 V c / 24 C 240 V a MLR1 Screw terminals A / At / B / C / H / Ht 12 V z MUR Di / D / Ac / Bw MUR3 Relay 1 x 8 A changeover 0.1 s C 100 h 12 C 240 V z Spring terminals MURc3 Screw terminals Ad / Ah / N / O / P Pt / TL / Tt / W 24 V c / 24 C 240 V a MXR1 A / At / B / C / H / Ht Di / D / Ac / Bw 24 C 240 V a MUS Screw terminals A Solid state 0.7 A 0.1 s C 100 h 24 C 240 V z MAS5 H / Ht MHS2 24 C 240 V a L / Li MLS2 240 V a EMAR7 A 110 V a EMAR Screw terminals Relay 1 x 5A changeover 0.1 s C 20 h 24 V z EMAR9 A / At / B / C / H / Ht Di / D / W / Pe 17.5 Screw terminals Ac / Ad / Bw / Cx / N / O / Tt Relay 1 x 5 A changeover 0.1 s => 20 h 12 C 240 V c / 24 C 240 V a 12 C 240 V c / 24 C 240 V a EMER EMYR8 Timers DIN rail industrial casings Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type A / At / B / C / H / Ht Di / D / Ac / Bw TUR1 A / At TAR1 B TBR Screw terminals C 1 x 8 A changeover 0.1 s C 100 h Relay 24 V c / 24 C 240 V a TCR1 H / Ht THR1 L / Li TLR1 Q TQR * RQR1* K 2 x 8 A changeover 0.1 s C 160 s TK2R1 1 x 8 A changeover TU2R4 A / At / B / C / H / Ht 1 inst. or timed 8 A 12 V z Di / D / Ac / Bw * RU2R4* Screw terminals 1 x 8 A changeover TUR Relay 0.1 s C 100 h TA2R1 A / At 2 x 8 A changeover 24 V c / 24 C 240 V a * RA2R1* A / At / B / C / H / Ht TUR3 1 x 8 A changeover 12 C 240 V z Spring terminals Di / D / Ac / Bw TURc Screw terminals Ad / Ah / N / O / P Pt / TL / Tt / W Q A / At / B / C / H / Ht Di / D / Ac / Bw Relay 1 x 8 A changeover 1 inst. or timed 8 A 1 x 8 A changeover 1 x 8 A changeover 1 inst. or timed 8 A 0.1 s C 100 h 24 V c / 24 C 240 V a 230 C 440 V a 12 C 240 V z 24 V c / 24 C 240 V a * Available in The casing of the new range will be different from the ones presented here. Further information can be found on the data sheets available at TX2R * RX2R1* TXR TQR * RQR6* TU2R * RU2R3* TU2R * RU2R1* 14 I l Panorama Crouzet Control 15

9 Selection guide Plug-in industrial casings Casing width (mm) Connections Functions (detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type Plug-in 8-pin base Plug-in 11-pin base Plug-in 8-pin base Plug-in 14-pin base A / At / B / C / H / Ht Di / D / Ac / Bw 1 x 8 A changeover OUR1 A 2 x 8 A changeover 24 V c / 24 C 240 V a OA2R1 C OCR1 Relay 0.1s C 100 h L / Li OLR1 A / At / B / C / H / Ht 1 x 8 A changeover 12 V z OUR4 Di / D / Ac / Bw 12 C 240 V z OUR3 A / At / B / C / H / Ht 1 x 8 A changeover Di / D / Ac / Bw 1 inst. or timed 8 A PU2R1 A 24 V c / 24 C 240 V a PA2R1 C Relay 2 x 8 A changeover 0.1s C 100 h PC2R1 L / Li PL2R1 A / At / B / C / H / Ht 1 x 8 A changeover 12 V z PU2R4 Di / D / Ac / Bw 1 inst. or timed 8 A 12 C 240 V z PU2R3 12 V c RTMA2 24 V c RTMA2 2 x 5 A changeover 24 V a RTMA2 110 V a RTMA2 A Relay 0.1s C 100 h 230 V a RTMA2 12 V c RTMA4 24 V c RTMA4 4 x 3 A changeover 24 V a RTMA4 110 V a RTMA4 230 V a RTMA4 Timers "Panel mounted", Timers Analogue - TMR48 series Digital Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type 48 x 48 Plug-in 11-pin base Plug-in 8-pin base L / Li - G / Gi TMR 48 L 2 timed changeover A, B, C, W, G, Ac, Bw TMR 48 U 2 x 5 A A 12 C 240 V c TMR 48 A Relay 2 timed changeover or 24 C 240 V a A1, A2, H1, H2, Q1, Q2, D-Di 1 timed and 1 instantaneous TMR 48 X (2 x 5 A) Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type 48 x x x x 48 Plug-in 8-pin base Plug-in 11-pin base Plug-in 11-pin base Plug-in 8-pin base Plug-in 11-pin base A Relay 2 timed changeover 2 x 5 A A, B, C, D, Di, H 1 x 8 A timed changeover A, B, C, D, Di, H A1, A2, AM, AMt A1, A1C, A2, A2C, AM, AMt, B, BM, C, CM, D, Di, DiM, Dpause, H, HM, T,TM, W, WM Accessories available: base socket 8-pin for DIN Rail mount , base socket 11-pin for DIN Rail mount Relay Relay 1 x 8 A timed changeover 2 timed changeover or 1 timed and 1 instantaneous (2 x 8 A) 2 timed changeover or 1 timed and 1 instantaneous (2 x 5 A) A, B, C, D, Di, H Relay 1 x 8 A timed changeover 24 V z Timer V a Timer C 240 V a Timer V c / 24 C 48 V z Timer V z / 110 C 240 V a Timer V c / 24 C 48 V z Timer V z / 110 C 240 V a Timer V c / 42 C 48 V z Timer V z / 110 V a Timer V c / 220 C 240 V a Timer V z / 100C240 V a Timer 815E 24 V z / 48 V z Timer V z / 110 V a Timer V z / 220 C 240 V a Timer V z / 48 V z Timer V z / 110 V a Timer V z / 220 C 240 V a Timer 816 The timer accessories guide is available on the product data sheets which can be downloaded from the website 16 I l Panorama Crouzet Control 17

10 Selection guide MBA series Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 22 (diameter) Screw terminals A Solid state 400 ma 22 (diameter) Screw terminals A Solid state 200 ma 0.1 s C 1 s MBA2F 0.5 s C 10 s MBA2F 3 s C 60 s 100 C 240 V z MBA2F 0.5 min C 10 min MBA2F 3 min C 60 min MBA2F 0.1 s C 1 s MBA3F 0.5 s C 10 s MBA3F 3 s C 60 s 24 V c MBA3F 0.5 min C 10 min MBA3F 3 min C 60 min MBA3F Timers Electromechanical - Top 2000 range Manual reset Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 48 x x 48 Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type Screw terminals Plug-in 8-pin base Screw terminals Plug-in 8-pin base Faston connectors 6.35 mm Faston connectors 6.35 mm Faston connectors 6.35 mm Relay Relay A A A Relay Relay Relay 1 timed changeover and 1 timed instantaneous (2 x 5 A) 1 timed changeover and 1 timed instantaneous (2 x 5 A) 1 x 16 A timed changeover 2 x 16 A timed changeover 3 x 16 A timed changeover 6 s C 12 mn 6 mn C 12 h 24 V a Top C 48 V a Top C 127 V a Top C 240 V a Top V a Top C 48 V a Top C 127 V a Top C 240 V a Top V a Top V a Top C 48 V a Top C 48 V a Top C 127 V a Top C 127 V a Top C 240 V a Top C 240 V a Top min (Max.display time : 4 min 40 s) min (Max.display time : 14 min) min (Max.display time : 28 min) min (Max.display time : 56 min) 127 / 230 V a min (Max.display time : 1 h 53 min) 50 Hz h (Max.display time : 4 h 43 min) h (Max.display time : 14 h 10 min) h (Max.display time : 28 h 20 min) min (Max.display time : 4 min 40 s) min (Max.display time : 14 min) min (Max.display time : 28 min) min (Max.display time : 56 min) 127 / 230 V a min (Max.display time : 1 h 53 min) 50 Hz h (Max.display time : 4 h 43 min) h (Max.display time : 14 h 10 min) h (Max.display time : 28 h 20 min) min (Max.display time : 4 min 40 s) min (Max.display time : 14 min) min (Max.display time : 28 min) min (Max.display time : 56 min) 127 / 230 V a min (Max.display time : 1 h 53 min) 50 Hz h (Max.display time : 4 h 43 min) h (Max.display time : 14 h 10 min) h (Max.display time : 28 h 20 min) The timer accessories guide is available on the product data sheets which can be downloaded from the website 18 I l Panorama Crouzet Control 19

11 Function diagrams U : Supply R : Output relay or load T : Timing : Infinity C (Y1) : Command Generic functions A function: Delay on energisation 1 relay Single shot timing which starts on energisation. Ac function: Timing after closing and opening of control contact 1 relay Ad function: Delay on energisation (cannot be reset) 1 relay After energisation, a control pulse or latching contact starts timing. At the end of timing, the output is excited. The output will be reset when a new control pulse or latching contact occurs. Ah function: Single shot flip-flop (cannot be reset) 2 timers or 2 relays including 1 instantaneous After energisation, closing of the control contact results in starting of the time delay T. Output relay "R" (or the load) changes state at the end of this time delay. After opening of contact C (Y1), relay "R" drops out after a second time delay T. After energisation, a control pulse or latching contact starts timing. At the end of timing, the output is excited. The time delay is then reset. At the end of this new time delay, the output reverts to its initial value. At function: Timing on energisation with memory AM function: Delay on energisation Latching during the time delay. AMt function: Delay on energisation Latching during and after the time delay. B function: Timing on impulse (one shot) - Shaping (cannot be reset) 1 relay After energisation, an impulse ( 50 ms) or a latching contact causes a change in state of the output relay "R" (or the load) which drops out at the end of timing. Bw function: Pulse output (adjustable) 1 relay 2 timers or 2 relays including 1 instantaneous On closing and opening of the control contact C (Y1), the output relay "R" (or the load) changes state for as long as the time delay lasts. C function: Timing after impulse True delay off (without auxiliary power supply) U : Supply R : Output relay or load T : Timing : Infinity C (Y1) : Command H function: Timing on energisation - Pulse output (adjustable) 1 relay On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the single shot cycle. Ht function: Delay on energisation with memory 1 relay Adds up the total opening time of a contact. On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the single shot cycle. K function: Delay on de-energisation True delay off (without auxiliary power supply) 1 relay L function: Asymmetrical flashing On energisation, the output relay "R" (or the load) changes state. On de-energisation timing starts and the relay "R" will only drop out at the end of this time delay. 1 relay Repetitive cycle with two times which can be set independently. 2 timers or 2 relays including 1 instantaneous Each time delay alternates with a different state of the output relay "R" (or the load). Note: The cycle starts with the relay "R"in the rest position. Li function: Asymmetrical flashing 1 relay Repetitive cycle with two times which can be set independently. P and Pe functions: Impulse counter (delay on) P function: Timing starts on energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 500 ms. Pe function: On energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 1 s. Pt function: Impulse counter (delay on) Q function: "Star-delta" starting TL function: Impulse relay Adds up the total opening time of a contact. At the end of timing, the output is excited for approximately 500 ms. On energisation, the "star" contact closes instantaneously and timing starts. At the end of timing the Ti "star" contact opens. After a pause of 40 to 100 ms the "delta" contact closes. After energisation, a control pulse or latching contact closes the relay. A second control pulse opens the relay. Timers 1 relay Adds up the opening time of a contact. Output relay "R" (or the load) changes state at the end of timing. A1 function: Delay on energisation 1 timer 1 instantaneous relay A2 function: Delay on energisation 2 timers. 1 relay After energisation, closing of the control contact C (Y1) results in the change of state of output relay "R" (or the load). Timing will only start when this contact opens. D or Di functions: Symmetrical flashing Repetitive cycle which alternately sets the output relay "R" (or the load) to operating and rest position for equal periods of time. 1 relay 1 relay D function: The cycle starts with relay "R" in rest position. Di function: The cycle starts with relay "R" in operating position. N function: "Safe-guard" O function: "Delayed safe-guard" On the first control pulse, the output is excited. If the interval between two impulses is longer than the timing value, this occurs normally and the output relay "R" (or the load) will change state at the end of timing. Otherwise, relay "R" stays in its original state until the condition is fulfilled. On energisation, a first timer runs and the output relay "R" (or the load) changes state. On the appearance of a control pulse, relay "R" returns to its initial position and stays there as long as the time interval between 2 impulses is less than the timing value. Otherwise, relay "R" will change state at the end of timing. Tt function: Timed impulse relay After energisation, a control pulse or latching contact closes the relay and starts timing. The relay opens at the end of timing or on a second control pulse. W function: Timing after pulse on control contact After energisation, opening of the control contact results in a change in the state of output "R" (or the load) and timing starting. 20 I l Panorama Crouzet Control 21

12 Function diagrams 815E dedicated functions A2 function: Delay on energisation U : Supply R :O utput relay or load T : Timing : Infinity C (Y1) : Command Start : Start timing Reset : Reset to zero TMR48 dedicated functions TMR48 A A function: D elay on A2c function: Delay on energisation AMt function: D elay on energisation AM function: Delay on energisation U : Supply R :O utput relay or load T : Timing : Infinity C (Y1) : Command energisation Ac function: T iming after closing and opening of control contact TMR48 U A function: O n-delay Timers B function: Timing on impulse (one shot) Latching during the time delay Latching during the time delay B function: Timing on impulse (one shot) B function with latching: Timing on impulse (one shot) A1 function: D elay on energisation Bw function: Pulse output (adjustable) C function: Timing after impulse D function: Flip-flop Di function with latching: Flip-flop C function with latching: T iming after impulse Di function: Flip-flop A2 function: D elay on energisation D-Di function: Symmetrical flashing D pause function: Flip-flop H1 function: T iming on energisation H function: Timing on energisation C function: Off-delay G function: Cyclical function H function with latching: T iming on energisation H2 function: T iming on energisation L/LiG/Gi function: Cyclical flashing timers T function: Timing on energisation T function with latching: T iming on energisation W function: O ff-delay 22 W function with latching: Off-delay timer I Q1 function: Star-delta "starting" Q2 function: " Star-delta 2" starting W function: Off-delay l Panorama Crouzet Control 23

13 Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Control relays Instinctive control 24 I

14 The basics A control relay How can it be defined in simple terms? The control relay is an electronic device which can be used to detect and monitor physical values or electrical values. If a device is found to be operating abnormally, the control relay trips to halt its operation. Crouzet Control, control relays C-Lynx modular housing and E, F, L industrial housing A control relay To execute which actions? Operating mode Sensitivity Control relays Protecting, Monitoring The control relay is used to protect machines by monitoring values such as current, voltage, phase presence and sequence, levels, etc. The control relay ensures total availability of equipment, a major challenge for industries keen to improve their productivity and operating profits. Protection Monitoring Operating mode Threshold Hysteresis Timing Relay output LED Power supply LED Threshold It is one of the indispensable monitoring components for ensuring continuity of service of each installation. Sensing, Alerting Sensing Power supply LED Relay output LED Timing If a fault is detected, the machine is not allowed to run and the user is informed of the anomaly by a visual signal. Thus alerted, the user can then correct any malfunctions. This avoids expensive breakdowns, synonymous with production delays and loss of profitability. Controlling, Triggering In level control, the control relay takes on a different role: it controls the pump in order to manage the level of water in a container (tank, swimming pool, sink, etc). Directly interfacing with probes, it triggers a signal and thus safeguards against machine breakdowns due to threshold adjustment. Alerting Controlling Triggering In addition to this catalog, the website offers technical data sheets and installation manuals for each product, available as free downloads. MUS (C-Lynx) ENRM (E, F, L) Crouzet Control, control relays Their features: Positive logic output to protect installations in the event of a power failure. True RMS guaranteed regardless of interference on the electrical supply. Better integration in industrial and commercial cabinets thanks to modular casings and industrial casings. Simplified installation thanks to a power supply for single-phase products and a self-powered version for three-phase products. The combination of a number of control functions in one unit optimises wiring time and simplifies installation. A range of power supplies from 24 to 240 V in one unit for optimised stocks. 26 I l Panorama Crouzet Control 27

15 Applications Crouzet Control, control relays Where are they found? In electrical cabinets associated with other automation functions for the following markets: Food industry Industrial automation systems Quarries Building equipment Water treatment Transport Generating set Frequency control in generating sets or detection of backup units. C-Lynx control relay (underfrequency/ overfrequency) HHZ Fountains Maintaining an adequate water level for the pumps or water jet to work properly, preventing no-load operation (which often irreparably damages the pumps, and always stops the water jet effect). Control relay HNM Control relays Lift Ice maker Motors Crushers Monitoring the internal temperature of the PTC probe. For lift machine rooms, monitoring the temperature between 4 and 40 C according to standard EN81. Fluid management: cold management compressor current control. Control of mains voltage (prevents overheating, destruction of insulation and change of direction). Motor protection, detection of anomalies (temperature too high, motor stopping). Detection of obstruction or jamming. C-Lynx thermocontrol relays for lifts HWT81 Current control relay MUS Motor temperature control relay HWTM Current control relay HIH Cranes Pump management Escalators Steam systems Monitoring overcurrent in the event of motor overload. When too high an overload occurs, the current exceeds the fixed threshold and the relay contact closes. Protecting the pump: detection of no-load operation by undercurrent control, detection of jamming by overcurrent control. Control/detection of phase sequence and failure on motors. Level control (maintaining a constant level). Current control relay MIC Current control relay HIH Phase control relay HWUA Level control relays ENRM 28 I l Panorama Crouzet Control 29

16 Selection guide C-Lynx modular housing, Control relays Phase control (3-phase supply) Phase failure Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output(s) Casing width (mm) Meas. range (Self-powered) Part number Type With 70 % regeneration Without regeneration Yes / No No / No No MWG No / -20 % C -2 % MWU Yes / 5 C 15 % No / No 0.1 C 10 s 1 x 5 A changeover C 480 V a - 50 / 60 Hz MWA Window +2 C +20 % -20 C -2 % MWUA Yes / No No / No No 1 x 5 A changeover MWS 208 C 480 V a - 50 / 60 Hz 1 x 5 A changeover EMWS x 5 A changeover 208 C 440 V a - 50 / 60 Hz MWS2 No / No 0.3 C 30 s 1 x 5 A changeover 208 C 480 V a - 50 / 60 Hz M3US Yes / 5 C 15% +2 C +20% / -20 C -2 % 0.1 C 10 s HWUA 2 x 5 A changeover C 480 V a - 50 / 60 Hz No / No 0.3 C 30 s H3US Loss of phase and neutral Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output relay Casing width (mm) Meas. range (Self-powered) Part number Type Control relays Without regeneration No / No +2 C +20 % / -20 C -2 % 0.3 C 30 s 2 x 5 A changeover C 277 V a - 50 / 60 Hz H3USN Motor temperature control and phase sequence and failure Sensor Test Latching Supply voltage Output relay Casing width (mm) Supply Part number Type PTC No No HWTM 24 C 240 V z 2 x 5 A NO C 480 V a Reset on front panel Yes HWTM2 Single-phase DC voltage control with selectable latching Measurement range Functions Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 9 C 15 V c MUS 20 C 80 V z Over / Undervoltage 5 % C 20 % 0.1 C 10 s 1 x 5 A changeover 17.5 Monitors its own supply voltage MUS 65 C 260 V z MUS 0.2 C 60 V z HUL Over or Undervoltage 5 % C 50 % 0.1 C 3 s 2 x 5 A changeover C 240 V z 15 C 600 V z HUH 20 C 80 V z Monitors its own MUSF Window 3% fixed 0.1 C 10 s 1 x 5 A changeover C 260 V z supply voltage MUSF Current control (over or undercurrent) Measurement range Built-in CT Hysteresis Latching / Timing Output relay Casing width (mm) Supply Part number Type 2 C 20 A a Yes 15% fixed No / No 1 x 5 A changeover MIC 2 C 500 ma z 24 C 240 V z HIL 0.1 C 10 A z No 5 % C 50 % Yes / 0.1 C 3 s 2 x 5 A changeover HIH The control relay accessories guide is available on the product data sheets which can be downloaded from the website 30 I l Panorama Crouzet Control 31

17 Selection guide Frequency control with window Measurement range Selectable latching Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 40 C 70 Hz Yes 0.3 Hz fixed 0.1 C 10 s 2 x 5 A changeover C 277 V a HHZ Level control Probe Emptying / Filling Level / Measurement range Timing Output relay Casing width (mm) Supply Part number Type Resistive 1 or 2 / 250 C 1 MΩ 2 x 5 A changeover HNM Yes / Yes 35 Digital or PNP / NPN 1 or 2 / None 0.1 C 5 s 24 C 240 V z HNE 1 x 5 A changeover Digital No / Yes 1 / None MNS Over/underspeed control Sensor Measurement range Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 3-wire NPN/PNP sensor, 0 C 30 V, NAMUR Volt-free contact 0.05 s C 10 min 5 % fixed 0.6 C 60 s 1 x 5 A changeover C 240 V z HSV Control relays Temperature control with window (lifts) according to EN81 Sensor Built-in phase control Measurement range Timing Output relay Casing width (mm) Supply Part number Type 3-wire Pt100 1 x 5 A changeover HT81 Low threshold -1 C +11 C 3-wire Pt100 No High threshold +34 C +46 C 0.1 C 10 s 2 x 5 A NO C 240 V z HT wire Pt100 Yes 480 V 2 x 5 A NO HWT81 Industrial housing E, F, L, Control relays Phase sequence or phase failure control Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output relay Casing width (mm) Meas. range (Self-powered) Part number Type 1 x 8 A changeover 200 C 500 V a EWS None Yes / No No / No No x 8 A changeover 200 C 460 V a EWS2 Voltage control with selectable latching Measurement range Functions Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 24 V c EUL 0.2 C 60 V z Over / Undervoltage 5 % C 50 % 0.1 C 3 s 1 x 8 A changeover V a EUL 120 V a EUL 230 V a EUL 24 V c EUH 15 C 600 V z Over / Undervoltage 5 % C 50 % 0.1 C 3 s 1 x 8 A changeover V a EUH 120 V a EUH 230 V a EUH The control relay accessories guide is available on the product data sheets which can be downloaded from the website 32 I l Panorama Crouzet Control 33

18 Selection guide Current control (over / undercurrent) Level control Measurement range With CT Hysteresis Latching / Timing Output relay Casing width (mm) Supply Part number Type 2 C 500 ma No 5 % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover C 10 A No 5 % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover C 100 A % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover 22.5 Probe Emptying / Filling Level / Measurement range Timing Output relay Casing width (mm) Supply Part number Type Resistive Yes / Yes 1 or 2 / 5 C 100 KΩ No Resistive Yes / Yes 2 / 250 Ω C 1 MΩ 0.1 C 5 s Resistive Yes / Yes 1 or 2 / 5 C 100 KΩ No 1 x 8 A changeover Resistive Resistive Motor temperature control Sensor Test Latching Manual reset Output relay Casing width (mm) Supply Part number Type PTC Combined with monitoring of wells Yes / Yes + Alarm No 2 / 5 C 100 KΩ No 1 x 8 A changeover Yes No 1 x 8 A NO Yes Yes 1 x 8 A changeover 1 x 8 A changeover x 8 A changeover 22.5 PTC No Yes Yes 2 x 8 A changeover Plug-in 8-pin base 39 Plug-in 11-pin base 39 Plug-in 11-pin base V a ENR 48 V a ENR 120 V a ENR 230 V a ENR 24 C 240 V a * ENR* 24 V a ENRM 48 V a ENRM 120 V a ENRM 230 V a ENRM 24 C 240 V a * ENRM* 24 V a LN 120 V a LN 230 V a LN 24 V a LN 120 V a LN 230 V a LN 24 V a L2N 120 V a L2N 230 V a L2N 24 V a FN 48 V a FN 2 / 5 C 100 KΩ No 2 changeover V a FN FN 230 V a 2 / 250 Ω C 5 KΩ FN LS * Available in The casing of the new range will be different from the ones presented here. Further information can be found on the data sheets available at 24 V c EIL 24 V a EIL 48 V a EIL 120 V a EIL 230 V a EIL 24 V c EIH 24 V a EIH 48 V a EIH 120 V a EIH 230 V a EIH 24 V c EIT 24 V a EIT 48 V a EIT 120 V a EIT 230 V a EIT 24 V a ETM 120 V a ETM 230 V a ETM 24 V a ETM V a ETM V a ETM 2 24 V a ETM V a ETM V a ETM 22 The control relay accessories guide is available on the product data sheets which can be downloaded from the website Control relays 34 I l Panorama Crouzet Control 35

19 Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Counters and Ratemeters Counting accuracy 36 I

20 The basics A counter, a ratemeter How can they be defined in simple terms? A counter can be used to count a number of actions or events. It thus participates in production management and preventive maintenance. A ratemeter can be used to display the speed of rotation of a motor in real time. Crouzet Control, counters and ratemeters A digital range and an electromechanical range A counter, a ratemeter To execute which actions? Operating time Power used Up counting, Down counting For up counting or down counting a number of parts, events, a running time, the counter is the ideal solution. There are different types of counter with the following functions: up/down counter, batch counter, ratemeter, chronometer, multi-totalizer, elapsed time counter, impulse counter. Informing, Displaying Up counting Down counting Informing Preset settings Enable Mode Counters and Ratemeters A counter can allow a user to be informed and to display data and quantities easily. The data displayed can be read directly on the front panel. Displaying CTR48 CEM48 Triggering, Actuating A counter can be used to trigger an action or an intervention on a machine. The outputs actuate directly and/or transmit data to the control system. Measuring, Chronometer timing A counter can be used to schedule preventive maintenance. The machine running time is measured and the duration of an action timed with a chronometer. Triggering Actuating Measuring Chronometer timing In addition to this catalogue, the website offers technical data sheets and installation manuals for each product, available as free downloads. Crouzet Control, counters and ratemeters Their features: For fast count applications, a high-speed counting frequency: up to 50 khz. A two-colour or backlit LCD dual display for ease of reading. Considerable space saving due to dualfunction electromechanical and electronic ranges. A complete output operating logic to cover complex applications. Easier maintenance thanks to removable connectors (CTR48). An enhanced multifunction electronic range for optimised stocks. 38 I l Panorama Crouzet Control 39

21 Applications Crouzet Control, counters and ratemeters Where are they found? Compressors Counting operating hours and counting the number of starts. Dehumidifiers Counting operating hours, energy consumption. In electrical cabinets associated with other automation functions for the following markets: Industrial automation systems Building equipment Industrial machines Medical ELECTROMECHANICAL hour and impulse counter CMM48 ELECTROMECHANICAL hour and energy counter CEM48 Tachometer systems Speed measurement and control on shrink wrapping machine. Counting quantities Managing quantities - Packaging by unit, batch or series of batches. Assembly line speed Control of conveyor movement speed. Milling machine Combined ratemeter and counter for controlling the position and speed of a router. Counters and Ratemeters Electronic counter CTR24L 2511 Electronic counter CTR48 Ratemeter CTR24L 2511 Electronic ratemeter AND counters CTR24L 2513 Length measurement Position control Lifts UV lamp Calculation of cut length on wood and paper machines. Managing quantities - Calculation of distance of travel. Combined impulse and hour counters - Maintenance. Start counters and operating time counters. Counting and display of operating times. Event management, wear control. Electronic counter CTR48 Electronic counter CTR48 Electronic counter CTR24L 2514 hour counter CTR I l Panorama Crouzet Control 41

22 Selection guide Electronic counters 24 x 48 multifunction counters without preselection Functions Totalizer or Hour counter or Ratemeter Modes Multiplication coefficient Decimal point Max. counting speed Display Counting capacity Supply Part number Type Dir / up.dn / up.up Yes Yes 50 khz (DIR mode) 999,999 Ph / 2-ph / 4-ph LED Start / Stop No Yes 999,999 hrs s C 999,999 hrs sec -1 / min -1 Yes Yes 50 khz 999, C 30 V c CTR24L Double totalizer Independent inputs (A and B) Totalizer and Ratemeter Independent inputs Counting A / B / A-B / A+B AdivB / %AB Dir / up.dn / up.up Ph / 2-ph / 4-ph sec -1 / min -1 Yes Yes 25 khz LED 999, C 30 V c CTR24L Yes Yes 30 khz LED 999, C 30 V c CTR24L Double totalizer Common input Totalizer + Ratemeter or Totalizer + Totalizer or Totalizer + Hour or Hour + Hour Counting (total / partial) Counting + sec -1 / min -1 Counting Counting + Start / Stop Yes Yes 50 khz LED 999, C 30 V c CTR24L Yes Yes 35 khz 50 khz 999, khz 999, ,999 hrs LED s C 999,999 hrs Start / Stop No Yes 999,999 hrs s C 999,999 hrs 10 C 30 V c CTR24L Counters and Ratemeters 24 x 48 counters without preselection Functions Inputs / Reset Max. counting speed Display Counting capacity Supply Part number Type PNP / Contact CTR Hour NPN or contact / Contact 99, hrs LCD 0.1 s C 99, hrs Lithium battery CTR Voltage / Contact CTR PNP / Contact CTR Hour NPN or contact / Contact 99, hrs Orange (backlit) 0.1 s C 99, hrs Lithium battery CTR Voltage / Contact CTR PNP / Contact CTR Totalizer NPN or contact / Contact 99,999,999 LCD 99,999,999 Lithium battery CTR Voltage / Contact CTR PNP / Contact CTR Totalizer NPN or contact / Contact 99,999,999 Orange (backlit) 99,999,999 Lithium battery CTR Voltage / Contact CTR The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website 42 I l Panorama Crouzet Control 43

23 Selection guide 48 x 48 multifunction counters with preselection Functions Number of preset(s) Max. counting speed Display Counting capacity Outputs Supply Part number Type Preselection counter Ratemeter Chronometer Multi-totalizer Preselection counter Ratemeter Chronometer Multi-totalizer Batch counter Preselection counter Ratemeter Chronometer Multi-totalizer Preselection counter Ratemeter Chronometer Multi-totalizer Batch counter Preselection counter Chronomètre Electromechanical counters Hour counters KHz 40 KHz 5 KHz Backlit LCD (orange) extra-bright 2 lines Two-colour LCD (red and green) 2 lines Backlit LCD (green) 2 lines -999,999 C 999, ,999 C 999, ,999 C 999,999 1 x 5 A changeover 1 solid state 1 x 5 A changeover 1 x 5 A NO 2 solid state 1 x 5 A changeover 1 solid state 1 x 5 A changeover 1 x 5 A NO 2 solid state 1 x 3 A changeover 1 x 3 A changeover 1 x 3 A NO 10 C 30 V c CTR48 24 V a CTR48 90 C 260 V a CTR48 10 C 30 V c CTR48 24 V a CTR48 90 C 260 V a CTR48 10 C 30 V c CTR48 24 V a CTR48 90 C 260 V a CTR48 10 C 30 V c CTR48 24 V a CTR48 90 C 260 V a CTR48 11 C 30 V c CTR48E 115 V a CTR48E 230 V a CTR48E 11 C 30 V c CTR48E 115 V a CTR48E 230 V a CTR48E Dimensions (mm) Counting capacity Frequency Supply Part number Type 20 C 30 V a CHM48 42 C 48 V a CHM48 50 Hz a 100 C 130 V a CHM C 440 V a CHM48 48 x 48 99, C 264 V a CHM48 20 C 30 V a CHM48 42 C 48 V a CHM48 60 Hz a 100 C 130 V a CHM C 264 V a CHM C 440 V a CHM48 10 C 30 V c CHM48 48 x , c 36 C 80 V c CHM C 130 V c CHM48 20 C 30 V a CHM24 50 Hz a 100 C 130 V a CHM C 264 V a CHM24 99, x C 30 V a CHM24 60 Hz a 100 C 130 V a CHM C 264 V a CHM24 999, c 10 C 30 V c CHM24 15 x 32 99, c 4.5 C 35 V c CHM15 24 V a CHMDR Modular 50 Hz a 115 V a CHMDR Rail Din 99, mm 230 V a CHMDR c 10 C 27 V c CHMDR The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website Counters and Ratemeters 44 I l Panorama Crouzet Control 45

24 Selection guide Impulse counters Dimensions (mm) Reset to zero Counting capacity Supply Part number Type 15 x 32 Clip-fixing 24 x 48 Clip-fixing 24 x 48 Clip-fixing 24 x 48 Screw-fixing 24 x 48 Screw-fixing 36 x 37 Screw-fixing 36 x 37 Screw-fixing 36 x 48 Screw-fixing 36 x 48 Screw-fixing No 9,999,999 No 999,999 Yes 99,999 No 999,999 Yes 999,999 No 999,999 Yes 999,999 No 999,999 Yes 999, V a - 50 / 60 Hz CIM V a - 50 / 60 Hz CIM V a - 50 / 60 Hz CIM15 5 V c CIM15 12 V c CIM15 24 V c CIM15 24 V a - 50/60Hz CIM V a - 50/60Hz CIM V c CIM V c CIM V a - 50/60Hz CIM V a - 50/60Hz CIM V c CIM V c CIM V a - 50/60Hz CIM 24 x V a - 50/60Hz CIM 24 x V a - 50/60Hz CIM 24 x V c CIM 24 x V c CIM 24 x V a - 50/60Hz CIM 24 x V a - 50/60Hz CIM 24 x V a - 50/60Hz CIM 24 x V c CIM 24 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V c CIM 36 x V c CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V c CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V c CIM 36 x V c CIM 36 x V c CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V a - 50/60Hz CIM 36 x V c CIM 36 x 48 Counters and Ratemeters Dual function 48 x 48 counters Functions Reset to zero Counting capacity Frequency Supply Part number Type Impulse Hour Power Hour No No 9,999,999 99, hrs 50 Hz a 60 Hz a 20 C 30 V a CMM C 130 V a CMM C 264 V a CMM48 20 C 30 V a CMM C 130 V a CMM C 264 V a CMM48 9,999,999 / 999, hrs c 10 C 30 V c CMM48 9,999,999 99, kw/hrs 50/60 Hz a 115 V a CEM V a CEM48 The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website 46 I l Panorama Crouzet Control 47

25 Connection diagrams CTR24 counters Connections Hour counters Impulse counters 1. NC 2. Start / Stop input 3. Reset input 4. Enable front panel Reset 5. Mode 1 (Time selection) 6. GND / Optional backlighting - (only 23xx) 7. Mode 2 (Time selection) 8. Optional backlighting + (only 23xx) 1. Fast count 2. Slow count 3. Reset input 4. Enable front panel Reset 5. Counting (counting direction) 6. GND 7. Optional backlighting - (only 23xx) 8. Optional backlighting + (only 23xx) Counters and Ratemeters Types 2223 and 2323: Types 2233 and 2333: Types 2241 and 2341: Types 2251 and 2351: Part numbers: Part numbers: Part numbers: Part numbers: Types 2224 and 2324: Part numbers: Common z 2. Start / Stop input 3. Reset input Types 2242 and 2342: Part numbers: Fast count 2. Common z 3. Reset input 4. Enable front panel Reset 4. Enable front panel Reset 5. Mode 1 (Time selection) 6. GND / Optional backlighting - (only 23xx) 7. Mode 2 (Time selection) 8. Optional backlighting + (only 23xx) 5. NC 6. GND 7. Optional backlighting - (only 23xx) 8. Optional backlighting + (only 23xx) 48 I l Panorama Crouzet Control 49

26 Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Temperature controllers A degree of constancy 50 I

27 The basics A temperature controller How can it be defined in simple terms? Crouzet Control, temperature controllers A complete range A temperature controller is an electronic device which is used to monitor and ensure a constant temperature according to a setpoint. A temperature controller To execute which actions? Measuring Measuring The temperature controller is used to measure and maintain the temperature of a room, an enclosure, a liquid. Functions It guarantees a constant temperature and ensures optimum use of the systems in which it is found: ovens, baths, cold rooms, machines. Controlling Programming mode Setpoint settings Controlling, Displaying, Alerting Directly interfacing with probes, the temperature controller controls and displays the temperature of the enclosure. Displaying CTD46 Temperature controllers It can be used to set an alert in the event of an anomaly (low and/or high temperature). Monitoring The temperature controller action is not limited to monitoring. It senses and controls the temperature, acting on the system heating or cooling. If the controlled temperature does not conform to the setpoint, the controller implements a heating or cooling action. Alerting Monitoring In addition to this catalogue, the website offers technical data sheets and installation manuals for each product, available as free downloads. Crouzet Control, temperature controllers Their features: Adaptive tuning products which manage their parameters independently: PID, temperature rise and inertia curve to simplify the installation. A sophisticated control algorithm to obtain a temperature as close as possible to the setpoint. A dual display makes it user-friendly and easy to use. Compatibility with all types of probe thanks to a "Multi-technology probe input". Multiple outputs (logic and/or relay) for optimum integration in any system. 52 I l Panorama Crouzet Control 53

28 Applications Crouzet Control, temperature controllers Where are they found? Chocolate factory Managing the temperature of the liquid chocolate before it is poured into a mould. Bain-Marie Maintaining the temperature of a bain-marie during cooking. In electrical cabinets associated with other automation functions for the following markets: Industrial automation systems Building equipment Food industry Temperature controller CTD43 Temperature controller CTD46 Packaging Fluid management Oven Cold room Monitoring the heating temperature of the various packages. Maintaining the temperature of a ceramic oven. Managing the temperature of an oven with change of setpoint possible via MODBUS. Maintaining a storage room at freezing temperature. Temperature controller MIC48 Temperature controller CTD43 Temperature controller MIC48 Temperature controller CTD46 Temperature controllers Brewing Cooking Air treatment plant Spray booth Managing cooling of fermentation tanks. Control of industrial ovens. Maintaining forced air at the correct temperature. Temperature control for "paint curing" in the motor vehicle industry. Temperature controller Mic48 Temperature controller CTD46 Temperature controller Mic48 Temperature controller CTD46 54 I l Panorama Crouzet Control 55

29 Selection guide Temperature controllers 48 x 48 digital Functions Type of control Alarm Input Output Display Supply Part number Type Heating or Cooling Heating or Cooling Heating and Cooling Heating and / or Cooling PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune Load break monitoring 1 alarm 1 alarm No 2 alarms 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, R, S,T, L, N or voltage or current 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 line (3 digits) 2 lines (3 digits) 2 lines (3 digits) 2 lines (4 digits) 24 V z CTD C 240 V a CTD43 24 V z CTD C 240 V a CTD43 24 V z CTD C 240 V a CTD46 24 V z CTD C 240 V a CTD46 24 V z CTH C 240 V a CTH46 24 V z CTH C 240 V a CTH46 24 V z MIC C 240 V a MIC48 24 V z MIC C 240 V a MIC48 Temperature controllers Accessories Description Part number Current transformer for MIC 48 (10 A / 50 ma) Current transformer for MIC 48 (25 A / 50 ma) Current transformer for MIC 48 (50 A / 50 ma) Current transformer for MIC 48 (100 A / 50 ma) Thermocouple probe J with nickel-plated brass eyelet - max: 400 C Thermocouple probe J with 304 stainless steel casing - max: 600 C Accessories (continued) Description Part number Thermocouple probe J with 316 stainless steel sheath - diameter 6 mm - max: 400 C Thermocouple probe J with 316 stainless steel sheath - diameter 5 mm - max: 400 C Thermocouple probe K with 304 stainless steel casing - max: 1100 C Pt100 probe Class B with 316 stainless steel sheath - max: 200 C Pt100 probe Class B with 316 stainless steel sheath - max: 400 C Pt100 probe Class B with aluminium V6 sheath - max: 200 C I l Panorama Crouzet Control 57

30 Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Safety relays User protection 58 I

31 The basics A safety relay How can it be defined in simple terms? Crouzet Control, safety relays A relevelling range and a machine safety range A safety relay is an automation component which is part of a machine's safety system, thus contributing to the safety of people around it. It is essential for compliance with machine safety standards (EN ISO and IEC/EN 62061). A safety relay To execute which actions? Power supply LED Power supply LED Protecting, Controlling The safety relay protects people. It controls a user's action to ensure that this does not lead to anything that may damage his health, either voluntarily or accidentally. Protecting Controlling Relay output LED Relay output LED Error indication LED Monitoring, Sensing When a machine may be dangerous for the user, it is necessary to monitor all hazardous operations, and detect the slightest anomaly. Monitoring KNA3-YS KSW3-JS Actuating It is then necessary to actuate safety contacts to stop cutting, rotating, burning items, etc which could be hazardous for the user. Sensing Actuating Crouzet Control, safety relays Their features: Safety relays In addition to this catalogue, technical data sheets for each product are available as free downloads on the website. A range covering machine applications: emergency stop and mobile guard monitoring, emergency stop with timed contact, two-hand control, zero speed monitoring, expansion module and power supply accessory. A relevelling control relay for the lift market. A safety component with one or two channels. Prohibition of machine starting if a problem becomes apparent through self-checking of the integrity of the control devices. A range conforming to: - Performance Level (PL) e and category 4 according to EN ISO Limit value SIL 3 (SIL CL) according to IEC/EN I l Panorama Crouzet Control 61

32 Selection guide Crouzet Control, safety relays, How to choose? Machine safety Function(s) Safety category Safety contacts Data contact Connection Casing width (mm) Supply Part number Type 24 V c Emergency stop & Safety guard monitoring with 1 channel 3 3 x NO 1 x NC Screw terminals Removable spring terminals V a V a V c V a KNA3-YS KNAC3-YS 230 V a V z Emergency stop & Safety guard monitoring with 2 channels 4 3 x NO 1 x NC Screw terminals V a V a KNE3-YS Removable spring terminals 24 V z KNEC3-YS Timed contacts 1 C 10 s 4 2 x NO (instantaneous) 1 x NO (timed) - Screw terminals V z KZR3-YS Expansion module for safety relays 4 (combined with a level 4 safety relay) 5 x NO 1 x NC (feedback loop) Screw terminals V z V a V a KZE5-YS Zero speed monitoring 4 3 x NO 1 x NC 1 x NO 2 x solid state outputs Screw terminals V c KSW3-JS Safety relays 2 x NO - 24 V c KZH2-Y2 Two-hand control 4 3 x NO 1 x NC Screw terminals V c V a KZH3-YS Power supply for 24 V c safety relays Screw terminals C 265 V z KPS0-YS Relevelling control according to EN 81-1, -2 (lift standard) Function(s) Safety category Safety contacts Data contact Connection Casing width (mm) Supply Part number Type Relevelling zone control for lifts 4 2 x NO - 24 V z KZHNU-YS Removable screw terminals x NC 24 V z KZHNV-YS 62 I l Panorama Crouzet Control 63

33 Applications Crouzet Control, safety relays Where are they found? Emergency stop and guard monitoring Emergency stop modules with 1 or 2 channels KNA3-YS and KNE3-YS, KNAC3-YS and KNEC3-YS SAFETY RELAYS Relevelling lift cars Levelling the landing and the lift car KZHNU-YS and KZHNV-YS SAFETY RELAYS Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. They can be found in electrical cabinets, associated with other automation functions in the following markets: Building equipment Industrial automation systems In addition to this catalogue, the website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Zero speed monitoring Sensorless control for stopping electric motors Two-hand control Control of two-hand control console Safety relays Single or three-phase KSW3-JS SAFETY RELAYS KZH2-YS and KZH3-YS SAFETY RELAYS 64 I l Panorama Crouzet Control 65

34 Notes Logic controllers Concentrated performance Smart & Essential 66 I

35 The basics Millenium 3 A logic controller How can it be defined in simple terms? Crouzet Automation Logic Controllers Millenium 3, concentrated performance The Millenium 3 Smart logic controller is a programmable logic controller which enables the control and monitoring of machines or automation installations with up to 50 I/O. A logic controller is a programmable module which is used to control small automation systems or small installations. It is an electronic device which combines all of Crouzet's historic expertise. The logic controller is a plural solution in a control system since it contains solutions that can replace a number of products: timers, counters, control relays, temperature controllers, impulse relays, etc. The logic controller operates as the brain of applications. It is capable of retrieving information and triggering actions; it can be adapted to suit the needs of customer applications. Timers more Control relays Counters Temperature controllers A logic controller To execute which actions? Power supply terminals Input terminals Controlling Controlling Blue screen with 4 lines of 18 characters Programming port The logic controller controls and automates a set of actuators according to the state of the sensors, the passing of time and the program created using the M3 Soft software. Measuring, Operator dialogue Measuring 6 programmable buttons Output terminals The logic controller integrates a local screen, a true operator interface, where the user can view the measured values. The buttons on the front panel are configurable and can be used in programs. The M3 Soft software can be used to design an installation easily, test it using simulation mode and communicate with the application with monitoring mode. Managing The logic controller easily performs and manages complex control system sequences, by means of integrated functions. Operator dialogue Managing Calculation of level of liquid in a tank Timers Digital or adaptive tune PID regulation Logic controllers Communicating, Triggering The logic controller can be used to communicate remotely with PCs or mobile phones via SMS across a network. It also incorporates a calendar to ensure the setting and triggering of actions. Communicating Triggering External preset Up/Down counter Sunrise Sunset Time To tackle simpler applications that still require a powerful logic controller, Crouzet Automation offers the Millenium 3 Essential range. The 12 VDC or 24 VDC Millenium 3 Essential range includes a variety of versions and is compatible with a large range of accessories. It is the right solution for simple needs. 68 I l Panorama Crouzet Automation 69

36 The range Accessories Crouzet Automation Logic Controllers The Millenium 3 Smart range Multiple configuration options derived from an extensive product range with numerous accessories Crouzet Automation Logic Controllers Accessories Sensors, power supplies, converters, remote screens and communication accessories offer solutions to control your automation systems with the greatest ease of use. Simplified connectivity making integration of communication systems easy Easy implementation supported by free, user-friendly programming software (M3 Soft) Application-specific solutions thanks to dedicated and easy to use specific function blocks Enhanced visibility on the display with high contrast, blue back lit LCD screen Expandable versions I Sensors Ambient temperature sensor NTC temperature probes Light sensor Ventilation duct temperature sensor Potentiometer I Memory cartridge Accessories I XD26 Compact versions XB26 XD10 XB10 Expandable kit Power supplies I Converters Power supplies from 7.5 to 240 W 5, 12 or 24 V Temperature and current/voltage converters Programmable touchpanels STN and GSM modems Bluetooth interface Communication solutions Logic controllers I CD20 CB20 CD12 CB12 Compact kit I Remote screens 70 I l Panorama Crouzet Automation 71

37 Communication solutions Crouzet Automation Logic Controllers Extensive Connectivity Options Solutions with close proximity to your installation Wide Area Network (WAN) solutions Millenium 3 Virtual Display - Bluetooth or USB M3MOD - GSM modem communication interface Your requirements Our solution Main functions Your requirements Our solution Main functions Viewing setpoints on a panel less than 10 m away Changing and modifying setpoints Locating the Millenium 3 display unit remotely Reading counters in the vicinity Remote viewing of the Millenium 3 display unit - on an Android smartphone via Bluetooth - on a PC via Bluetooth or USB Display/modification of program setpoints Access to a virtual panel (Millenium 3 without display unit) In summary Bluetooth interface (10 m): Millenium 3 accessory Two versions: Lite (ESC/ENTER buttons disabled) & Standard Receiving remote early warning of an event Consulting a value or an internal state Occasionally modifying setpoints GSM Automatic notification of alarms via SMS Input and output states, as well as all program values, can be polled and controlled remotely Reports can be produced using the available variables Management of telephone contacts In summary Reliable plug & play solution that is simple to install Solution managed using M3 Soft software Option to send SMS messages via a telecom operator service MTP programmable touch panels - RS232 cable Remote management solutions with (2) - Cloud Your requirements Displaying data on a graphic panel Modifying setpoints from the touch panel Taking control of the remote panel from a distance Our solution Option VNC link (1) Main functions Supervision of your installation Use of Millenium 3 internal data, processing alarms and recipes Display of text, data, graphics, animations Archiving of data Customization of interfaces (picture library) Remote control of panel In summary Storage: 128 MB flash memory, SD card and USB key Direct communication using the Millenium 3 programming port Programmable with EB software (compatible with Windows 2000/XP/Vista/7) Extensive connectivity Your requirements Supervising and monitoring installations with up to 50 remote I/O Managing an installed base of machines Accessing your data remotely, 24/7 Optimizing your maintenance operations Our solution Millenium 3 Netbiter EC220 GPRS Millenium 3 Netbiter EC150 Internet Modbus Internet (via router or ADSL box) Main functions Remote control of an automated application Display of Millenium 3 program parameters and values via the internet Remote setpoint modification Data logging Management of events sent via s or SMS In summary Direct communication between Netbiter and Millenium 3 via the SLin/SLout protocol or via Modbus GPRS: SIM card procured via HMS Cloud solution: secure remote server Easy to set up and use Several Millenium 3 can be connected via Modbus Local Area Network (LAN) solutions (1) VNC: Virtual Network Computing. Allows a device to be controlled remotely. (2) Partnership solutions with the HMS company, validated by Crouzet Automation and HMS. Information relating to the products has been provided by the supplier of each product respectively, and they are wholly responsible for its accuracy in addition to supplying and providing backup for their products. Programmable touch panels and communication extensions Modbus networks Your requirements Managing a group of machines or an installation on a local area network Centralizing data Displaying data on a graphic panel Modifying setpoints from the panel Accessing the system locally in real time Our solution Modbus Main functions See MTP programmable touch panels solution Management and centralizing of data in a single place Display of Millenium 3 program values Remote setpoint modification In summary MTP panel Modbus master XN05 extension: Modbus Ethernet TCP/IP XN06 extension: Modbus RS485 RTU Communication extensions - Modbus RS485 or Modbus Ethernet TCP/IP Your requirements Managing a group of machines or an installation on a local area network Centralizing data Accessing the system locally in real time Our solution Modbus Main functions Can be combined with distributed automation Management and centralizing of data in a single place Display of Millenium 3 program values Remote setpoint modification In summary Uses Modbus protocol XN05 extension: Modbus Ethernet TCP/IP XN06 extension: Modbus RS485 RTU Compatible with standard supervisors Logic controllers 72 I l Panorama Crouzet Automation 73

38 M3 Soft software Crouzet Automation Logic Controllers Millenium 3 and M3 Soft The M3 Soft is a high-performance software platform used to program the Millenium 3 logic controller and optimize design times. Free The Millenium 3 programming software (M3 Soft) can be downloaded free of charge from the Crouzet website at M3 Soft software Its features Simple Quick, simple and intuitive programming requires no specialist knowledge Self-teaching made easier thanks to a user-friendly online help guide and programming examples A simulation mode that consistently represents controller operation Powerful A complete range of basic functions: counting, timing, comparison, display, logic, gain, sin/cos, etc are also available A wide range of dedicated functions: pump rotation, PID regulation, movement, pressure, level, water ratio, solar tracking, and flow User-friendly and ergonomic Software available in 5 languages: English, French, Italian, German and Spanish Function block programming is fun and very visual Blocks simply organized by function for quick access Help associated with each function block accessible at the click of a button Programming langages: FBD (Function Bloc Diagram) and SFC (Sequential Function Chart/ Grafcet) or LD (Ladder Diagram) User-definable and effective Logic controllers Possibility of creating and saving custom macros in the macro tab allowing the user to simplify programs and utilize their expertise Blocks can be wired in wiring mode or text mode Move one or more blocks without disconnecting the wires Choice of programming language Possibility of protecting macros by locking them with a password for greater security Clear work area Customized password protection 74 I l Panorama Crouzet Automation 75

39 Function blocks APPLICATION INPUTS/OUTPUTS CALCUL CONTROL Cam Bloc Control of a group of 8 integral cam wheels. Gain Conversion of an analog value by changing the scale and offset. Discrete Input Integer Input Timer Large set of timer functions (A/C, BW, B/H,Li/L, Totalizer) Angular Cam Timer Cam timer with the angle made by the cams as the command input. Add/Subb Simple operations on integers: Addition and/or Subtraction. Filtered Digital Input Discrete Output Schmitt Trigger Monitoring of an analog value in relation to two thresholds. Pumps management Pumps Management (Tank Management with circular pump changeover). Mul/Div Simple operations on integers: Multiplication and/or Division. Analog Input 0..10V PWM Output Timer A Delay of actions for a predefined time. Sunrise Sunset Time Calculation of the sunrise and sunset time in relation to the latitude and longitude. ADD/SUB 2 Inputs The ADD-SUB (Addition or Subtraction) function is used to perform simple operations on integers. Filtered Analog Input Analog Output Expansions 10 bits Bistable Impulse relay function. Solar Tracking one Axis Calculation of the sun's position so that a sun dial can be placed. Sin/Cos Calculation of the cos and sin of an angle between 0 and 90. Analog Input Expansion 10 bits Integer Output Set Reset Bistable memory - Priority assigned to either SET or RESET. Analog PID Regulation (8 bits) Temperature control (pressure or other) with 8 bitsanalog output. Square Root Calculation of the square root of the number present as an input with accuracy to two decimal points. Analog Input Expansion 12 bits Timer Set Reset Trigger of operation of a particular device at a fixed time for a period set by the user. PWM PID Regulation (8 bits) Temperature control (pressure or other) with 8 bitsdigital output. Bit Multiplexer Copy of the selected A or B input to the outputs Q and/q. One Second Clock The blinking input function is active every second. Pressure Gain Interface between a Pressure Sensor and the Millenium 3 logic controller. Multiplexer A B Multiplexing function on 2 analog values. Compare in Zone Comparison of a value between two setpoints (the MIN and MAX values determine the zone). Flow Calculation of the flow of a liquid in a pipe using a differential pressure element or by measuring the dynamic pressure. Demultiplexer Demultiplexing of integers. Used to direct the value of the input to one of the 4 outputs. Display B Button Compare Comparison of two analog values using the =, >, <, >=, <=, =/= operators. Level Calculation of the level of a liquid with or without constant density, in an open or closed tank, using pressure sensors. Multiplexer Multiplexing word inputs. Used to direct the value of one of the selected inputs to a predefined output. Text ESC Button MULTI COMPARE Activation of the output corresponding to the value present on the "Value" input. CTN 1 Temperature measurement It is dedicated to CTN1 (-25 to +85 C). Dec/Bin Break down of an integer type input (16 bits) into 16 bit type outputs. Menu Scroll Minus Button HL Switch Comparison of a value against 5 thresholds. CTN 2 Temperature measurement. It is designed for CTN2 type CTNs (-35 C to +120 C). Bin/Dec LCD Backlight Output Plus Button Make up of an integer type output (16 bits) from 16 bit type inputs. Min Max Saving of the minimum and maximum values of a variable signal. CTN 3 Temperature measurement. It is designed for CTN3 type CTNs (0 C to +200 C). SPLIT 16 bits to 4 Split of a 16-bit word into four 16-bit words with values between 0 and 15. A Button OK Button Reduced Average Update of the configured average of a number of values by deleting the minimum and maximum values. LUX-I Light measurement It is designed for photoresistors and internal light meters. SPLIT 16 bits to 2 Split of a 16-bit word into two 16-bit words with values between 0 and 255. Time Prog Daily, weekly, monthly and yearly time programmer. Twilight Calculation of the sunrise and sunset times and also the twilight times in relation to the latitude and longitude read on the function block inputs. Word Shift Register Shifting of the 16-bit words on each rising edge of the clock. Weekly Time Prog Daily, weekly, monthly and yearly time programmer. Solar Tracking Dual Axis Calculation of the sun's position so that a sun dial can be placed. This positioning depends on the two angles calculated by the function: the elevation angle and the azimuth angle. Shift Register Shifting of information by saving it to the memory (shifting of bits in a 16-bit word on each rising edge of the clock). Preset Counter Preset up/down counter Filtration time information in relation to the water Transfer Function Table of correspondence between the X input and the Y output.the table of correspondence is created from a csv file Up Down Counter External preset up/down counter. Transfer Function 50 values Table of correspondence between the X input and the Y output.the table of correspondence (50 rows max) is created from a sv file Preset H Meter Preset hour counter (preselection of hour, minute). Timer Transfer Function Correspondence table for the Minutes operating time and the Y output. High speed count Counting of the pulses arriving at the inputs of a controller powered by a DC supply at rates in excess of one pulse every 6 ms. Timer Transfer Function 50 values Correspondence table for the Minutes operating time and the Y output. (50 Values) Fast count Counting of the pulses arriving at the input at rates in excess of one pulse every 10 ms. Swimming Pool Filtration temperature. Defrost Defrost cycle management Heat Curve Modulation of the heating water temperature according to the atmospheric conditions. The function uses automatic regulation depending on the temperature outdoors called the temperature curve or "water ratio". Analog PID Regulator (Auto-tuning) Auto-tuning proportional-integral-derivative (PID) controller. PROG XA HMI COMMUNICATION c SL In Writing via serial link of data stored in the controller s fixed addresses SL_In S (saved) Data transmission via a programming port to memory space in the controller s fixed addresses. Data is protected in the event of disconnection of the controller SL Out Reading via programming port of data stored in the controller s fixed addresses. Alarm Control of 10 alarm levels and distribution of a serial data to a digital output, connected to a modem digital input. For example to send a SMS. Message distribution of alarm messages to mobile phones, to the Millenium 3 Alarm tool or to addresses via the M3MOD GRAFCET SFC PROG Resettable Initial Step When RESET function is activated, activation of the STEP OUTPUT for the function, which is the initial step, and reinitialization of all of the ther active steps. LOGIC Constant On Constant On Hour Minute Indication of the time from the controller (hour and minutes). Initial Step Initial step of an SFC chart Not Or 6 Inputs Constant Off Constant Off Hr Mn Converter Conversion of a time period in the "hour : minute" format to minutes and vice versa. Step A step of an SFC chart. And 2 Inputs Nand 4 Inputs Yes Bit Copy of the input to the output. (very helpful when macros are being used) Controller Status Access to the controller states and modify the behaviour of its FBD and/or SFC program depending on these states. Or Divergence Step Transition of one step to be simultaneously made toward one or two steps. And 4 Inputs Nor 4 Inputs Numerical Constant Integer with a value between and Summertime Active function throughout summer time, and inactive throughout winter time. Or Convergence Transition of one to four step(s) to be simultaneously made toward one step. And 6 Inputs Xor 2 Inputs Yes Num Copy of the input to the output. (very helpful when macros are being used) And Divergence Transition of one or two steps to be simultaneously made toward two steps. Or 2 Inputs Boolean 6 Inputs/2 Outputs Memory Saving of a value between and And Convergence Step Transition of two steps to be simultaneously made toward one step. Or 4 Inputs Boolean Wait SFC Step Set up of a wait phase or step for a PLC or a device. Move SFC Step Set up of a move step for a motor controlled by the PLC to a position specified on the TARGET input. Motor Multiplexer Combination of the motor control signals produced by two linked MOVE SFC steps. macros Display 15 texts Display of 15 texts one after each other with 15 Displays Function Blocs Storage Storage of data values with an average value. Archive Saving of two values simultaneously with the information relating to their time-stamping. Scroll 4 lines Scroll down of a text of four lines on the screen of the Controller Random Generation of a pseudo-random value between the min and max values set by the user. My Macro Possibility to create a personal macro library and to store them in the Macro tab. 76 I Logic controllers Function block marked in red: CTN 1 l Panorama Crouzet Automation Available only for the Millenium 3 Smart Range 77

40 Applications Crouzet Automation Logic Controllers Where are they found? Buidling Equipment Access Control Infrastructure and Energy Fluid management Swimming pools, fountains, spas Managing circulation pumps, monitoring levels, temperature and conductivity of the water Irrigation/Sprinklers Irrigation control based on temperature, humidity, and day/night cycle Opening control for doors Opening control for doors and other associated security devices for restricting access; synchronization between the various doors Automatic barriers Control barriers with automatic detection of vehicles. Function for selecting opening times / days. filtration Filtration duration settings depending on the water temperature PUMP MANAGEMENT Pump rotation function BOOLEAN OR LOGIC Create logic equations between the connected inputs UP/DOWN COUNTER Up/Down counter with external preset Water treatment Reverse osmosis Pump management HVAC Heat pump Air treatment plant Circulation pumps management, supervision of flow pressure and temperature of osmosis processed water Circulation pumps management, supervision of levels and pressure Management of various parameters such as heating, cooling, fluid temperatures, operation, calendar-based function, frost protection mode, alarm management, etc Maintaining forced air at the correct temperature FLOW Calculation of the flow of a liquid in a pipe CTN Temperature measurement (-35 to +120 C) GAIN Conversion of an analog value by changing the scale and datum point LEVEL Calculation of the level of liquid in a tank Building Automation WATER RATIO Water temperature control CLOCK Weekly and yearly time programmer Solar water heating Automation of operation and heating regulation, remote management of the installation NTC1 Temperature measurement REGULATION Analog PID regulation GAIN Conversion of an analog value by changing the scale and datum point Illuminated signs Managing flashing on illuminated signs Industrial OEMs Packing machines Stretch wrapping machines Controlling the motor that unrolls the packing film. Controls cutting of the film after heat sealing and monitors the duration of the motor cycles Packaging Controlling heat sealing times on blister packs, packaging bags, etc Logic controllers TEMPERATURE CONTROL (pressure or other) WEEKLY TIME PROGRAMMER Programming of time slots during which it will be possible to execute actions LUX-I Measurement of the light level TWILIGHT Calculation of the sunrise and sunset times GRAFCET SFC FUNCTIONS For sequential automation systems (Sequential Function Chart) TIMERS (TEMPORISATEURS) A/C function - BW function - B/H function - Li/L function HIGH SPEED COUNT Counting of pulses AND Logical AND with 2 inputs Other typical applications: Medical, Solar, Agricultural Equipment, Transportation, Hoisting, Handling 78 I l Panorama Crouzet Automation 79

A / At MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h

A / At MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h Chronos 2 DIN rail mounted, DIN rail modular casings Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type 88 827 105 MUR1 17.5 / t 88 827 115 MR1 B 0.1 s C 100

More information

Close supervision. Simplicity of use. Productivity gains. Control relay. C-Lynx. Instinctive control

Close supervision. Simplicity of use. Productivity gains. Control relay. C-Lynx. Instinctive control Close supervision Simplicity of use Productivity gains Control relay C-Lynx Instinctive control C-Lynx Control relay 1 Close-up protection for total availability of equipment! By installing a control relay,

More information

Micro-control. Control system solutions adapted to your applications. Overview. b Logic controllers. b Control relays. b Timers.

Micro-control. Control system solutions adapted to your applications. Overview. b Logic controllers. b Control relays. b Timers. 08 Overview Micro-control Control system solutions adapted to your applications b Logic controllers b Control relays b Timers Overview Micro-control Contents b Presentation of the offer P. 4-5 b Overviews

More information

Micro-control. Control system solutions adapted to your applications. b Logic controllers.

Micro-control. Control system solutions adapted to your applications. b Logic controllers. 09 Micro-control Control system solutions adapted to your applications Logic controllers Overview Micro-control Contents Presentatio Overviews Micro-cont Editorial For over 40 years, Crouzet has estalished

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Hour Meters / Timers, electronic

Hour Meters / Timers, electronic Hour Meters / Timers, electronic LED Timers Codix 523 For use as a timer, hour meter or short-time meter Pulse width measurement (operating time) Time interval measurement (start/stop) DC 000000 0... 30V

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

Time meter electronic

Time meter electronic Time meter electronic Universal with dual functions CODIX 52U 000000 0... 30V DIN 24 x 48 Power supply dimensions -0 +50 65 Wide temperature range High IP protection rating Powerful Fast count input Input

More information

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly The Codix 923/924 can be used universally. As a preset pulse counter, tachometer or preset timer with up to 6 presets it is able to solve a very wide range of control and monitoring tasks in every application.

More information

02/11/2015

02/11/2015 24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on

More information

Catalogue Ignitors and power switches for HID

Catalogue Ignitors and power switches for HID Catalogue 2012 Ignitors and power switches for HID Overview Product overview Ignitor matrix Standards Page 6 Page 7 Page 8 Product information Ignitors and power switches for HID Page 9 Superimposed-pulse

More information

Preset counters, electronic

Preset counters, electronic LCD preset counters Adding or subtracting (battery) 901 Type 901 is a simple battery powered preset pulse counter with 12... 250 V AC/DC count and reset input. The 6-digit, 2-line LCD display shows the

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

Eaton Durant. Counters, process instruments and hour meters.

Eaton Durant. Counters, process instruments and hour meters. Alltid Always tillgänglig available - Alltid öppen! - Always open! Electronic totalizers, LCD display - 1/32 DIN 24x mm Eaton Durant Catalogue Weight Type number kg/each Totalizer, add/subtract, NPN/PNP

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

PRINCIPLES AND APPLICATIONS

PRINCIPLES AND APPLICATIONS GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

G1-M1 (Protection Relay)

G1-M1 (Protection Relay) G1-M1 (Protection Relay) Defining G1 and M1 series protection relays in simple terms G1 and M1 series protection relays are the automation devices which measures electrical values and detects failures.

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

Counting and Process Technology 2009 / 2010

Counting and Process Technology 2009 / 2010 Counting and Process Technology 2009 / 200 W Pulse Counters W Preset Counters W Timers / Hour Meters W Tachometers / Frequency Meters W Position Displays W Multifunction Counters W Energy Counters W Process

More information

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Limit Detection nivotester FTC 420/421/422 Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay Timer and switching relay Timer and switching relays Timers Power-on delayed Power-off delayed Power-on and power-off delayed Switch-on and/or switch-off wiping (pulse shaper) Function timer relay Clock

More information

Simply clever! The digital DIN-rail time switches by Grässlin

Simply clever! The digital DIN-rail time switches by Grässlin Simply clever! The digital DIN-rail time switches by Grässlin talento pro Trends and developments on the market. Maximum energy efficiency at low efforts In a saturated fast-moving market, the trend towards

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT Universal Control Unit UC-1-E User Manual General Information Universal Control Unit UC-1 Of Central Lubrication CC DC 24 V 5A / M 15 SL /MK 31 M Z 30 General Information Contents Universal Control Unit

More information

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry. SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.

More information

Electrical connection

Electrical connection Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Data Acquisition Networks. Installing and Configuring the DM01 Hardware Data Acquisition Networks Installing and Configuring the DM Hardware What is the DM? D.A.N developed the DM-2 to capture 6 analogue measurements and pulse count in the field. The Average, Maximum and Minimum

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Page 1 of 7 Preselection and multifunction up/down counters 48x48 - CPT4 - Electronic multifunction counters CPT4 - LCD - 6 x 9 mm digits Selling points of the range Preselection counter, Tachometer, Timer,

More information

15 Series - Dimmer

15 Series - Dimmer Features Master slave system for multiple load dimming Suitable for incandescent and halogen lighting loads (with or without transformer or electronic supply) Compatible with energy saving (CF or ED) dimmable

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Pulse Counters, electronic

Pulse Counters, electronic LCD Pulse Counters Codix 0 RoHS Low-price and high efficiency Large -digit LCD display, height of the figures mm [0. ] Optional backlighting Simple counter for fast and slow count pulses, counting direction

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Clamp 200 A AC/DC (+ V AC/DC + Ω) PCE-DC1 Clamp meter 200 A AC/DC & Freq. LC display 3 2/3 digits, with backlight measures AC / DC current, AC voltage & frequency Hold function / DC A zero reset function tests voltage without contact automatic

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63 Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC

More information

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

s w i t c h i n g c o n t r o l l i n g c o u n t i n g s w i t c h i n g c o n t r o l l i n g c o u n t i n g S A V E T I M E I L L U M I N A T E S A V E E N E R G Y C O N N E C T F E E L W E L L A C C E S S O R I E S 2 014 switching controlling counting

More information

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators GDA-4K KNX GDA-8K KNX Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...

More information

Time-Lag Relays. User s Handbook (General Model)

Time-Lag Relays. User s Handbook (General Model) Time-Lag Relays User s Handbook (General Model) 651.601.387 Rev: V39 Date: 09/2016 Electrotécnica Arteche Smart Grid, S.L. This document, including texts, photos, graphics and any other content, is protected

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver.   Product description. Benefits. Interfaces. Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Preset counters, electronic

Preset counters, electronic With its automatic help texts, clearly and legibly displayed on 14 LED segments, the Codix 560 preset counter takes the user effortlessly through the programming. The large user-friendly front keys can

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic preselection counter Contents Page 1 General Information / Safety instructions 2 2 Getting to know the counter 4 2.1 Counter components 4

More information

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY 5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY Efficiency in focus The process industry puts a constant focus on efficiency

More information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24 GRASSLIN - MIL 72 SERIES (24-Hour, 7-Day) 24-HOUR TIME CONTROL SYNCHRONOUS WITHOUT OVERRIDE WITH 3-WAY OVERRIDE QUARTZ 7-DAY CARRY-OVER**With 3-Way Override Time based control of lighting, ventilating,

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

Digital Input Modules for Compact FieldPoint

Digital Input Modules for Compact FieldPoint Digital Modules for Compact FieldPoint NI cfp-di-300, NI cfp-di-301, NI cfp-di-304, NI 8-,16-, or 32-channel inputs 24 VDC inputs 4 to 250 VDC inputs 15 to 250 VAC inputs (50/60 Hz AC) 3 to 250 VAC inputs

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control Kitchen light control Bedroom light control 15 SЕRES iving room light control ighting control in corridors (for hotels, offices and hospitals) FDER reserves the right to alter characteristics at any time

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

STX Stairs lighting controller.

STX Stairs lighting controller. Stairs lighting controller STX-1795 The STX-1795 controller serves for a dynamic control of the lighting of stairs. The lighting is switched on for consecutive steps, upwards or downwards, depending on

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

XTM72E & F Real-Time Clock Modules

XTM72E & F Real-Time Clock Modules Capricorn Controls Ltd Data & Application Notes Page 1 of 8 XTM72E & F Real-Time Clock Modules Originally designed to compliment our wide range of Gen-Set controls, these DC powered Real-Time-Clocks have

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor 165 VARIABLE SPEED USER MANUAL Premium Efficiency Variable Speed Motor COPYRIGHT Copyright 2013, Regal Beloit America, Inc. Tipp City, Ohio. All rights reserved. TRADEMARKS All trademarks and registered

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

Operating instructions - High Performance LED Timer / / /

Operating instructions - High Performance LED Timer / / / Operating instructions - High Performance LED Timer 0 742 201/ 0742 202/ 0 742 251/ 0 742 252 Your tico 742 timer is a powerful instrument which can be field configured to fit a wide variety of applications.

More information

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry. Safety along the complete line: 3SE7 cable-operated switches Answers for industry. Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product range,

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

Solution Selection Guide

Solution Selection Guide Solution Selection Guide 2015-2016 Automation Systems Motion & Drives Sensing Control Components Switching Components Safety Timers & Counters V Contents Selection Guide V-ii Digital Timers H5CX-N Digital

More information

SAPLING WIRED SYSTEM

SAPLING WIRED SYSTEM SAPLING WIRED SYSTEM Sapling 2-Wire System DESCRIPTION The Sapling 2-Wire System is one of the most innovative and advanced wired systems in the synchronized time industry. It starts with the SMA Series

More information

INSTALLATION & USER GUIDE

INSTALLATION & USER GUIDE INSTALLATION & USER GUIDE Digidim 458 8-Channel Dimmer STEP 1 Assemble Dimmer Unit STEP 2 Mount Dimmer Chassis STEP 3 Electrical Installation STEP 4 Attach Module and Make Connections STEP 5 Replace Cover

More information