MT9810B Optical Test Set Operation Manual

Size: px
Start display at page:

Download "MT9810B Optical Test Set Operation Manual"

Transcription

1 MT9810B Optical Test Set Operation Manual Ninth Edition For safety and warning information, please read this manual before attempting to use the equipment. Keep this manual with the equipment. ANRITSU CORPORATION Document No.: M-W1886AE-9.0

2 Safety Symbols To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Corporation uses the following safety symbols to indicate safety-related information. Ensure that you clearly understand the meanings of the symbols BEFORE using the equipment. Some or all of the following symbols may be used on all Anritsu equipment. In addition, there may be other labels attached to products that are not shown in the diagrams in this manual. Symbols used in manual DANGER This indicates a very dangerous procedure that could result in serious injury or death if not performed properly. WARNING CAUTION This indicates a hazardous procedure that could result in serious injury or death if not performed properly. This indicates a hazardous procedure or danger that could result in light-to-severe injury, or loss related to equipment malfunction, if proper precautions are not taken. Safety Symbols Used on Equipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions. Ensure that you clearly understand the meanings of the symbols and take the necessary precautions BEFORE using the equipment. This indicates a prohibited operation. The prohibited operation is indicated symbolically in or near the barred circle. This indicates an obligatory safety precaution. The obligatory operation is indicated symbolically in or near the circle. This indicates a warning or caution. The contents are indicated symbolically in or near the triangle. This indicates a note. The contents are described in the box. These indicate that the marked part should be recycled. MT9810B Optical Test Set Operation Manual 28 June 2001 (First Edition) 9 May 2008 (Ninth Edition) Copyright , ANRITSU CORPORATION. All rights reserved. No part of this manual may be reproduced without the prior written permission of the publisher. The contents of this manual may be changed without prior notice. Printed in Japan ii

3 For Safety WARNING 1. ALWAYS refer to the operation manual when working near locations at which the alert mark shown on the left is attached. If the advice in the operation manual is not followed there is a risk of personal injury or reduced equipment performance. The alert mark shown on the left may also be used with other marks and descriptions to indicate other dangers. 2. IEC Standard The IEC standard specifies four categories to ensure that an instrument is used only at locations where it is safe to make measurements. This instrument is designed for measurement category I (CAT I). DO NOT use this instrument at locations specified as category II, III, or IV as defined below. Measurement category I (CAT I): Secondary circuits of a device that is not directly connected to a power outlet. Measurement category II (CAT II): Primary circuits of a device that is directly connected to a power outlet, e.g., portable tools or home appliance. Measurement category III (CAT III): Primary circuits of a device (fixed equipment) to which power is supplied directly from the distribution panel, and circuits running from the distribution panel to power outlet. Measurement category IV (CAT IV): Building service-line entrance circuits, and circuits running from the service-line entrance to the meter or primary circuit breaker (distribution panel). 3. Laser radiation warning NEVER look directly into the cable connector on the equipment nor into the end of a cable connected to the equipment. There is a risk of injury if laser radiation enters the eye. The Laser Safety label is attached to the equipment for safety use as indicated in "Laser Safety" later in this section. iii

4 For Safety WARNING Electric Shock 4. To ensure that the instrument is earthed, always use the supplied 3- pin power cord, and insert the plug into an outlet with an earth terminal. If power is supplied without earthing the equipment, there is a risk of receiving a severe or fatal electric shock or causing damage to the internal components. Repair 5. This equipment cannot be repaired by the operator. DO NOT attempt to remove the equipment covers or unit covers or to disassemble internal components. Only qualified service personnel with a knowledge of electrical fire and shock hazards should service this equipment. There are high-voltage parts in this equipment presenting a risk of severe injury or fatal electric shock to untrained personnel. In addition, there is a risk of damage to precision components. Calibration 6. The performance-guarantee seal verifies the integrity of the equipment. To ensure the continued integrity of the equipment, only Anritsu service personnel, or service personnel of an Anritsu sales representative, should break this seal to repair or calibrate the equipment. If the performance-guarantee seal is broken by you or a third party, the performance of the equipment cannot be guaranteed. Be careful not to break the seal by opening the equipment or unit covers. Falling Over 7. This equipment should always be positioned in the correct manner. If the cabinet is turned on its side, etc., it will be unstable and may be damaged if it falls over as a result of receiving a slight mechanical shock. Always set up the equipment in a position where the power switch can be reached without difficulty. iv

5 For Safety CAUTION Fuse Replacement 1. Always remove the mains power cable from the power outlet before replacing blown fuses. There is a risk of electric shock if fuses are replaced with the power cable connected. Always use new fuses of the type and rating specified on the rear panel of the instrument. There is a risk of fire if a fuse of a different rating is used. T2A indicates a time-lag fuse. Cleaning 2. Keep the power supply and cooling fan free of dust. Clean the power inlet regularly. If dust accumulates around the power pins, there is a risk of fire. Keep the cooling fan clean so that the ventilation holes are not obstructed. If the ventilation is obstructed, the cabinet may overheat and catch fire. v

6 For Safety Class 1, 1M indicate the danger degree of the laser radiation specified below according to IEC :2001. Class 1: Lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Class 1M: Lasers emitting in the wavelength range from to 4000 nm that are safe under reasonably foreseeable conditions of operation, but may be hazardous if the user employs optics within the beam. Two conditions apply: a) for diverging beams, if the user views the laser output with certain optical instruments (for example, eye loupes, magnifiers and microscopes) within a distance of 100 mm; or b) for collimated beams, if the user views the laser output with certain optical instruments (for example, telescopes and binoculars). Class I, IIa, II, IIIa, IIIb indicate the degree of danger of the laser radiation outlined below as defined by 21 CFR :1995. Class I: Class I levels of laser radiation are not considered to be hazardous. Class IIa: Class IIa levels of laser radiation are not considered to be hazardous if viewed for any period of time less than or equal to seconds but are considered to be a chronic viewing hazard for any period of time greater than seconds. The wavelength range of laser radiating is in 400 to 710 nm. Class II: Class II levels of laser radiation are considered to be a chronic viewing hazard. The wavelength range of laser radiating is in 400 to 710 nm. Class IIIa: Class IIIa levels of laser radiation are considered to be, depending upon the irradiance, either an acute intrabeam viewing hazard or chronic viewing hazard, and an acute viewing hazard if viewed directly with optical instruments. The wavelength range of laser radiating is in 400 to 710 nm. Class IIIb: Class IIIb levels of laser radiation are considered to be an acute hazard to skin and eyes from direct radiation. vi

7 For Safety CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. The use of optical instruments with this product will increase eye hazard. vii

8 For Safety WARNING Laser Safety Before using this instrument, always ensure that the warning light is lit when the optical output switch is turned on. If this warning light does not turn on, the equipment may be faulty and for safety reasons should be returned to an Anritsu service center or representative for repair. The laser in the plug-in unit provided for this equipment is classified as Class 1, 1M according to the IEC :2001 standard, or as Class I, IIIb according to the 21 CFR :1995 standard. Never use optical instruments to directly view Class 1M laser products. Doing so may result in serious damage to the eyes. Table 1 Laser Safety Classifications Based on IEC :2001 Model Name Class Max. Optical Output Power (mw) * Pulse Width (s)/ Repetition Rate Emitted Wavelength (nm) Laser Aperture MU954501A Class 1 10 CW 1550 Fig. 1, [1] MU952501A Class 1M 40 CW Fig. 1, [1] MU952502A Class 1M 40 CW Fig. 1, [1] MU952503A Class 1M 40 CW Fig. 1, [1] MU952504A Class 1M 40 CW Fig. 1, [1] MU952505A Class 1M 40 CW Fig. 1, [1] MU952601A Class 1M 40 CW Fig. 1, [1] MU952602A Class 1M 40 CW Fig. 1, [1] MU952603A Class 1M 40 CW Fig. 1, [1] MU952604A Class 1M 40 CW Fig. 1, [1] MU952605A Class 1M 40 CW Fig. 1, [1] MU952606A Class 1M 40 CW Fig. 1, [1] MU951301A Class 1M 40 CW 1310 Fig. 1, [1] MU951501A Class 1M 40 CW 1550 Fig. 1, [1] MU951001A Class 1M 40 CW 1310/1550 Fig. 1, [1] *: Indicates the possible optical output power when each and every reasonably foreseeable single-fault condition is included. viii

9 For Safety Model Name Table 2 Laser Safety Classifications Based on FDA21 CFR :1995 Class Max. Optical Output Power (mw) Pulse Width (s)/ Repetition Rate Emitted Wavelength (nm) Laser Aperture MU954501A Class I 10 CW 1550 Fig. 1, [1] MU952501A Class IIIb 40 CW Fig. 1, [1] MU952502A Class IIIb 40 CW Fig. 1, [1] MU952503A Class IIIb 40 CW Fig. 1, [1] MU952504A Class IIIb 40 CW Fig. 1, [1] MU952505A Class IIIb 40 CW Fig. 1, [1] MU952601A Class IIIb 40 CW Fig. 1, [1] MU952602A Class IIIb 40 CW Fig. 1, [1] MU952603A Class IIIb 40 CW Fig. 1, [1] MU952604A Class IIIb 40 CW Fig. 1, [1] MU952605A Class IIIb 40 CW Fig. 1, [1] MU952606A Class IIIb 40 CW Fig. 1, [1] MU951301A Class IIIb 40 CW 1310 Fig. 1, [1] MU951501A Class IIIb 40 CW 1550 Fig. 1, [1] MU951001A Class IIIb 40 CW 1310/1550 Fig. 1, [1] ix

10 For Safety Table 3 Indication Labels on Product Type Sample Affixed to: Model Name 1 Explanation Fig. 1, A MU954501A 2 Explanation Fig. 1, B 3 Explanation Fig. 1, C MU952501A/02A/03A/04A/05A MU952601A/02A/03A/04A/05A/06A MU951301A MU951501A MU951001A MU952501A/02A/03A/04A/05A MU952601A/02A/03A/04A/05A/06A MU951301A MU951501A MU951001A 4 Certification Fig. 1, D MT9810B MT9812B 5 Identification Fig. 1, E MT9810B MT9812B 6 Warning Fig. 1, F 7 Aperture Fig. 1, G MU954501A MU952501A/02A/03A/04A/05A MU952601A/02A/03A/04A/05A/06A MU951301A MU951501A MU951001A MU954501A MU952501A/02A/03A/04A/05A MU952601A/02A/03A/04A/05A/06A MU951301A MU951501A MU951001A x

11 For Safety Laser Radiation Markings E D A B C G F [1] Fig. 1 Locations of Laser Beam Apertures and Affixed Labels xi

12 For Safety CAUTION Replacing Memory Back-up Battery This equipment uses a Poly-carbomonofluoride lithium battery to backup the memory. This battery must be replaced by service personnel when it has reached the end of its useful life; contact the Anritsu sales section or your nearest representative. Note: The battery used in this equipment has a maximum useful life of 7 years. It should be replaced before this period has elapsed. Use in a residential environment This instrument is designed for an industrial environment. In a residential environment this instrument may cause radio interference in which case the user may be required to take adequate measures. xii

13 Equipment Certificate Anritsu Corporation certifies that this equipment was tested before shipment using calibrated measuring instruments with direct traceability to public testing organizations recognized by national research laboratories, including the National Institute of Advanced Industrial Science and Technology, and the National Institute of Information and Communications Technology, and was found to meet the published specifications. Anritsu Warranty Anritsu Corporation will repair this equipment free-of-charge if a malfunction occurs within one year after shipment due to a manufacturing fault, under the condition that this warranty is void when: The fault is outside the scope of the warranty conditions described in the operation manual. The fault is due to mishandling, misuse, or unauthorized modification or repair of the equipment by the customer. The fault is due to severe usage clearly exceeding normal usage. The fault is due to improper or insufficient maintenance by the customer. The fault is due to natural disaster including fire, flooding, earthquake, etc. The fault is due to use of non-specified peripheral equipment, peripheral parts, consumables, etc. The fault is due to use of a non-specified power supply or in a nonspecified installation location. In addition, this warranty is valid only for the original equipment purchaser. It is not transferable if the equipment is resold. Anritsu Corporation shall assume no liability for injury or financial loss of the customer due to the use of or a failure to be able to use this equipment. Anritsu Corporation Contact In the event that this equipment malfunctions, contact an Anritsu Service and Sales office. Contact information can be found on the last page of the printed version of this manual, and is available in a separate file on the CD version. xiii

14 Notes On Export Management This product and its manuals may require an Export License/Approval by the Government of the product's country of origin for re-export from your country. Before re-exporting the product or manuals, please contact us to confirm whether they are export-controlled items or not. When you dispose of export-controlled items, the products/manuals need to be broken/shredded so as not to be unlawfully used for military purpose. xiv

15 Crossed-out Wheeled Bin Symbol Equipment marked with the Crossed-out Wheeled Bin Symbol complies with council directive 2002/96/EC (the WEEE Directive ) in European Union. For Products placed on the EU market after August 13, 2005, please contact your local Anritsu representative at the end of the product's useful life to arrange disposal in accordance with your initial contract and the local law. xv

16 CE Conformity Marking Anritsu affixes the CE conformity marking on the following product(s) in accordance with the Council Directive 93/68/EEC to indicate that they conform to the EMC and LVD directive of the European Union (EU). CE marking 1. Product Model Model: MT9810B Optical Test Set 2. Applied Directive EMC: Directive 2004/108/EC LVD: Directive 2006/95/EC 3. Applied Standards EMC:Emission: EN 61326: A1: A2: A3: 2003 (Class A) Immunity:EN 61326: A1: A2: A3: 2003 (Annex A) IEC (ESD) IEC (EMF) IEC (Burst) IEC (Surge) IEC (CRF) IEC (V dip/short) Performance Criteria* B A B B A B *: Performance Criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. Harmonic current emissions: EN : A2: 2005 (Class A equipment) LVD: EN : 2001 (Pollution Degree 2) xvi

17 4. Authorized representative Name: Loic Metais European Quality Manager ANRITSU S.A. France Address, city: 16/18 Avenue du Québec SILIC 720 Zone de Courtaboeuf Les Ulis Cedex Country: France xvii

18 C-tick Conformity Marking Anritsu affixes the C-tick mark on the following product(s) in accordance with the regulation to indicate that they conform to the EMC framework of Australia/New Zealand. C-tick marking 1. Product Model Model: MT9810B Optical Test Set 2. Applied Standards EMC:Emission: EN 61326: A1: A2: A3: 2003 (Class A equipment) xviii

19 Power Line Fuse Protection For safety, Anritsu products have either one or two fuses in the AC power lines as requested by the customer when ordering. Single fuse: A fuse is inserted in one of the AC power lines. Double fuse: A fuse is inserted in each of the AC power lines. Example 1: An example of the single fuse is shown below: Fuse Holder Example 2: An example of the double fuse is shown below: Fuse Holders xix

20 xx

21 About This Manual This manual provides descriptions of the operation, calibration and maintenance methods of the MT9810B Optical Test Set. Section 4 outlines the basic functions and operations of this device. Indicator indicates item numbers for which more detailed explanations and relevant descriptions are available. Moreover, matters that require attention in terms of operations and useful information are given as "Point"; use these as reference. It is possible to connect the computer to execute remote control of this device or capture measured values into the computer. See the following manual for more information on the interface to connect the computer. MT9810B Remote Control Operation Manual (M-W1887AE) This device can be used in combination with MG9541A Tunable Laser Source. See the following manual for using combined device. MX789400A Optical Component Raster Control Software Operation Manual (M-W1926AE) Index Appendix I

22 Table of Contents For Safety... iii About This Manual... I Section 1 General MT9810B Optical Test Set Plug-in Unit Main Functions Features Section 2 Nomenclature and Function Unpacking Front Panel Back Panel Indicator Display and Function of Key Switch Front Panel of Plug-in Unit Section 3 Before Use Installation Connecting the Power Cord Mounting and Removal of Plug-in Unit Connecting Specialized Optical Sensor Connection Cable Measuring High-Power Output Laser Safety Connection of Remote Interlock Connector Optical Output Modifier Key Switch Connection of Optical Fiber Cable Replacement of Optical Connector Replacement of Fuse Others II

23 Section 4 Operation Let's start! Optical Sensor Operations Light Source Operations System Setup Section 5 Performance Test and Calibration Optical Sensor Performance Test Light Source Performance Test Performance Test Results Calibration Section 6 Maintenance and Re-Transportation Daily Care and Cleaning Matters Requiring Attention for Storage Re-Transportation Error Indication in Self Diagnostics Troubleshooting Appendix A Specifications... A-1 Appendix B Ordering Information... B-1 Appendix Index Appendix C Default Setting... C-1 Appendix D Error Code... D-1 Appendix E Performance Test Result Recording List... E-1 III

24 Appendix F Overrange and Underrange Indication when Optical Sensor is Used... F-1 Index... Index-1 IV.

25 Section 1 General This chapter provides an outline of functions of the MT9810B Optical Test Set and the plug-in unit, and explanations of the product structure MT9810B Optical Test Set Plug-in Unit Main Functions Features General As for functions, operating method, specifications, etc. for high-speed measurement by the MU Sensor Adapter + the MA9332A/33A Optical Sensor, refer to the MX789400A Operation Manual (M-W1926AW) provided with the MU931002A. 1-1

26 Section 1 General 1.1 MT9810B Optical Test Set The main unit of the MT9810B Optical Test Set (hereafter referred to as the Device ) forms the core of a group of optical test set models. It has slots to enable mounting of two plug-in units. The Device is designed to operate units mounted in the slots and display the status and measured results. 1.2 Plug-in Unit The Device enables mounting of the units shown below. MU931311A Optical Sensor High-sensitivity type MU931421A Optical Sensor General-purpose type MU931422A Optical Sensor General-purpose type MU931431A Optical Sensor High-power type Appendix A Specifications Appendix A Specifications Appendix A Specifications Appendix A Specifications MU931001A + MA9331A Sensor Adapter + Optical Sensor Pull-out High-power Type Appendix A Specifications MU931001A + MA9332A Sensor Adapter + Optical Sensor Pull-out General-purpose Type Appendix A Specifications MU931002A + MA9332A Sensor Adapter + Optical Sensor for Optical Component Tester Appendix A Specifications 1-2

27 1.2 Plug-in Unit MU931002A+MA9333A Sensor Adapter + Optical Sensor for Optical Component Tester Appendix A Specifications MU952501A - MU952505A Light Source DFB-LD light source (With optical frequency variable function.) Appendix A Specifications MU951301A Light Source FP-LD light source Appendix A Specifications 1 General MU951501A Light Source FP-LD light source MU951001A Light Source Switchable FP-LD light source Appendix A Specifications Appendix A Specifications MU952601A - MU952606A Light Source DFB-LD light source (With optical frequency variable function.) Appendix A Specifications See the ordering information to select the model name and option number when specifying the optical frequency (wavelength) of the light source. Appendix B Ordering Information Incidentally, to specify an optical connector, add the double figure shown below together with a hyphen at the end of each unit model name. The absence of the double figure means to specify a unit with an FC connector. Unit with a FC connector (Model name)-37 Unit with an ST connector (Model name)-38 Unit with a DIN connector (Model name)-39 Unit with an SC connector (Model name)-40 Unit with a HMS-10/A connector (Model name)-43 Unit with an MU connector (Model name)-32 Note: An MU connector can only be specified with the MU931422A/ MA9331A/32A/33A unit. Appendix B Ordering Information 1-3

28 Section 1 General 1.3 Main Functions Function to vary the wavelength Varies the center optical frequency of the DFB-LD light source to the maximum of ±60 GHz. Switching display between optical frequency and wavelength Switches display between optical frequency and wavelength in the vacuum state. Function to vary the interval of the light power measurement Sets the interval of the light power measurement to the optimum value of the application, for example, short intervals for high-speed measurement and long intervals for long-time measurement. Function to vary the bandwidth of the light power measurement Sets the bandwidth appropriate for the measurement target, for example, slow bandwidth for the measurement of the mean power of the pulsed light and quick bandwidth for the measurement of the light power surge at the time of light switch switchover. Function to measure the maximum and minimum values and fluctuations of the light power Enables instantaneous evaluation of the light source stability and PDL characteristics without recording the measured values of the light power into memory as the maximum and minimum values measured of the light power and its fluctuations are constantly on display. Function to record measurement conditions Records a maximum of nine measurement conditions for each channel. (Default setting is separately kept.) Function to copy the measurement conditions When units of the same type are used on Channel 1 and Channel 2, the measurement conditions for one of the units can be copied for the other. Therefore, two identical measuring instruments can be made available instantaneously. Function to record measured values of the light power Records a maximum of 1,000 measured values of the light power per channel. It is possible to read the measured values by remote control and to use them for a range of analyses and processing. Interlocking Operations with Tunable Laser Source With Sensor for Optical Component Tester (MU931002A + MA9332A/33A), Wavelength characteristics of the optical filters, etc. can be measured at highspeed by interlocking with MG9541A Tunable Laser Source. Refer to the MX789400A Optical Component Tester Controls Software Operation Manual for details on standard accessories for the MU931002A Sensor Adapter. 1-4

29 1.4 Features 1.4 Features Wide dynamic range Enables measurement of optical loss of up to 120 db when a high output light source of +10 dbm and a high sensitivity optical sensor that measures up to dbm are used. High output and stability DFB-LD light source Enables high precision measurement despite high output of +10 dbm as high stability of limited deviations of ±0.005 db and center optical frequency not exceeding ±2 GHz are achieved. Compatible with wavelength conforming to ITU-T Provides a lineup of DFB-LD light sources of optical frequencies conforming to ITU-T compatible with Dense-WDM. Available at intervals ranging from and THz/100 GHz. High-precision light power measurement (MU931311A/1421A/22A/ MA9332A) Enables high-precision measurement of the light power as the reference condition, operating condition and linearity achieve precision of deviations not exceeding ±2%, ±3.5% and ±0.01 db, respectively. High return loss and low polarized wave dependency (MU931311A/1421A) Optimum for evaluation of devices and systems which use the optical amplifier as the return loss exceeds 40 db, signifying small amount of light returned and the polarized wave dependency is limited to not greater than 0.02 db, in the absence of adapters and other equipment to reduce reflection. High-speed light power measurement Enables measurement of the light power at a minimum interval of 1 ms by using the recording and measuring function. High-speed analog output (MU931311A) Demodulates intense modulated radiation of a maximum of 100 khz (3 db bandwidth). High resolution light power measurement Enables light power measurement at high resolution of 1/10000 db on the display of MT9810B set at resolution of 1/1000 db when GPIB and RS-232C are used. Standard mounting of GPIB and RS-232C As RS-232C in addition to GPIB is mounted as the standard remote interface, remote control can be enabled by using the notebook-sized personal computer. Moreover, the LabVIEW driver for remote control is also attached with a standard feature. High Output Optical Power Measurement (MU931431A/MA9331A) (MU931431A: up to +33 dbm) High output optical power up to +35 dbm can be measured. 1 General 1-5

30 Section 1 General AHigh-speed wave characteristics measurement (MU931002A+MA9332A/ 33A) Enables wave characteristics of the optical components at high-speed (10 µs or less, wave length: 500 points) by combination with the MG9541A. Point Although RS-232C is named EIA-232-E in accordance with the formal standards of ANSI/EIA, this document and descriptions relating to the Device use the general name of RS-232C for explanations. 1-6.

31 Section 2 Nomenclature and Function This chapter provides the nomenclature of each section on the front and back panels of the Device as well as explanations of functions and operations. 2.1 Unpacking Front Panel Back Panel Indicator Display and Function of Key Switch Front Panel of Plug-in Unit Optical Sensor (MU931311A/1421A) Optical Sensor (MU931422A/31A) Sensor Adapter (MU931001A/02A) Optical Sensor (MA9331A/32A/33A) Light Source Nomenclature and Function 2-1

32 Section 2 Nomenclature and Function 2.1 Unpacking Take the main unit and the plug-in unit out from the packing carton and check the articles provided with the component list. If any article is found missing or broken, quickly contact ANRITSU or an ANRITSU dealer. Example of components Item Name Quantity Model Name/Ordering No. Main unit Optical Test Set 1 MT9810B Standard accessories AC power source code 1 Tripolar to bipolar conversion adapter 1 J A fuse 2 T2.0 A250 V Remote interlock connection plug 1 J0896 Remote interlock short plug 1 J0895 Optical output modifier key 2 Z0391 Operation manual (this document) 1 W1886AE Operation manual for remote control 1 W1887AE LabVIEW driver 1 MX981001A Blank panel 1 B0425 Plug-in unit components Item Name Quantity Model Name/Ordering No. Main unit Optical Sensor 1 MU931311A 1 MU931421A 1 MU931422A 1 MU931431A Light Source 1 MU951301A 1 MU951501A 1 MU951001A 1 MU952501A 1 MU952502A 1 MU952503A 1 MU952504A 1 MU952505A 1 MU952601A 1 MU952602A 1 MU952603A 1 MU952604A 1 MU952605A 1 MU952606A 2-2

33 2.1 Unpacking Plug-in unit components Item Name Quantity Model Name/Ordering No. Main unit Sensor adapter 1 MU931001A Standard accessories Optical sensor connection cable 1 J1073A 2 Plug-in unit components Item Name Quantity Model Name/Ordering No. Main unit Sensor adapter 1 MU931002A Standard accessories Optical sensor connection cable 1 J1073A Optical Component Tester Control Software 1 MX789400A MX789400A Operation Manual 1 W1926AE Nomenclature and Function MU931001A Optical Sensor Components for Sensor Adapter Item Name Quantity Model Name/Ordering No. Main unit Optical sensor 1 MA9331A MU931001A/02A Optical Sensor Components for Sensor Adapter Item Name Quantity Model Name/Ordering No. Main unit Optical sensor 1 MA9332A MU931002A Optical Sensor Components for Sensor Adapter Item Name Quantity Model Name/Ordering No. Main unit Optical sensor 1 MA9333A 2-3

34 Section 2 Nomenclature and Function 2.2 Front Panel [4] Indicator [2] Plug-in slot [1] Power switch [6] Tilting leg [5] Key switch ([3] Blank panel) [6] Tilting leg [1] Power switch A switch to turn ON/OFF the power source. Pressing the switch (I) turns the power source ON. Pressing it again to switch it into the projected state (0) turns the power source OFF. [2] Plug-in slot Places to mount units. When no units are mounted, blank panels can be mounted. The left side is Channel 1 and the right side is Channel 2. [3] Blank panel A cover to be used when no units are mounted. (It is not possible to concurrently mount the blank panel and the unit.) [4] Indicator Displays the measured value and set value. 2.4 Indicator [5] Key switch Keys to operate the Device. 2.5 Display and Function of Key Switch [6] Tilting leg Legs affixed to the bottom face. Lifting up the legs and tilting the Device when the Device is set up at an elevation lower than eye level makes it easier to view the display. Caution Do not place any object on the Device when the tilting legs are lifted as the tilting legs or the Device may be broken. This may cause the Device to tip over or fall, causing injuries. 2-4

35 2.3 Back Panel 2.3 Back Panel [2] RS-232C [1] GPIB interface connector [2] interface connector [3] AC power source inlet 2 [9] Trigger input connector [5] Remote interlock connector [6] Short plug [7] Optical output [7] modifier key switch [4] Functional earth terminal [8] External equipment control connector Nomenclature and Function [1] GPIB interface connector GPIB interface to connect an external computer and execute remote control of the Device. [2] RS-232C interface connector RS-232C interface to connect an external computer and execute remote control of the Device. [3] AC power source inlet A connector for the AC power source input, with a built-in fuse. 3.8 Replacement of Optical Connector [4] Functional earth terminal A terminal to connect the ground line to ground the Device to ensure safety. [5] Remote interlock connectora connector for laser safety. In the open status, no light will be output even when the light output switch on the front panel of the light source is turned ON. 3.5 Connection of Remote Interlock Connector [6] Short plug A plug to switch the remote interlock connector into the shortcircuited status and enable optical output. 3.5 Connection of Remote Interlock Connector [7] Optical output modifier key switch A switch with a key for the purpose of laser safety. When the switch is set OFF, no light will be output even when the light output switch on the front panel of the light source is turned ON. [8] External equipment control connector A connector to control the MN96[][]A Optical Channel Selector. See the operation manual of the Optical Channel Selector. 2-5

36 Section 2 Nomenclature and Function [9] Trigger input connector Connector for inputting the trigger signals of the MG9541A Tunable Laser Source. For connection and use, refer to the MX789400A Optical Component Tester Control Software Operation Manual. Point Although RS-232C is named EIA-232-E in accordance with the formal standards of ANSI/EIA, this document and descriptions relating to the Device use the general name of RS-232C for explanations. 2-6

37 2.4 Indicator 2.4 Indicator [1] [2] [8] [10] [12] [4] [5] [14] [16] [18] [7] [9] [11] [13] [15] [17] 2 [3] [19] [1] Control CH1 display The underline lights up when the control target channel is CH1, or CH1 and CH Switching Channels Switching Channels [2] REF CH display Lights up at the time of reference measurement. The CH on display indicates the channel to constitute the reference value Reference Measurement [6] Nomenclature and Function [3] Seven-segment display Displays the measured value of the optical sensor used on CH1 and the output status of the light source. [4] Control CH2 display The underline lights up when the control target channel is CH2, or CH1 and CH Switching Channels Switching Channels [5] REF CH display Lights up at the time of reference measurement. The CH on display indicates the channel to constitute the reference value Reference Measurement [6] Seven-segment display Displays the measured value of the optical sensor used on CH2 and the output status of the light source. [7] AUTO Lights up when the range setting of the optical sensor used on CH1 is auto Setting Measurement Range [8] MOD Lights up when the optical sensor used on CH1 is set at modulated radiation measurement or the light source is set at modulated radiation measurement Setting Optical Modulation Mode Setting Optical Modulation Mode 2-7

38 Section 2 Nomenclature and Function [9] AVG Lights up when the optical sensor used on CH1 is set at average measurement Average Setting [10] CAL Lights up when the optical sensor used on CH1 is set at CAL measurement Calibration Measurement [11] SYS Lights up at the time of system function setting. 4.4 System Setup [12] PRMTR Lights up at the time of parameter setting for the unit. 4.2 Optical Sensor Operations 4.3 Light Source Operations [13] AUTO ights up when the range setting of the optical sensor used on CH2 is auto Setting Measurement Range [14] MOD Lights up when the optical sensor used on CH2 is set at modulated radiation measurement or the light source is set at modulated radiation measurement Setting Optical Modulation Mode Setting Optical Modulation Mode [15] AVG Lights up when the optical sensor used on CH2 is set at average measurement Average Setting [16] CAL Lights up when the optical sensor used on CH2 is set at CAL measurement Calibration Measurement [17] APPL Lights up when the application function is selected. 4.2 Optical Sensor Operations 4.3 Light Source Operations [18] REMOTE Lights up in the remote status when GPIB or RS-232C is connected. 2.5 Display and Function of Key Switch [19] Message display Displays the system setting, parameter setting, error contents and other details. Also displays the bar graphs to represent level meter indication when the optical sensor is used and to represent set optical frequency (wavelength) indication when the light source is used. 2-8

39 2.5 Display and Function of Key Switch 2.5 Display and Function of Key Switch Key Representation Local Shift Chan System Prmtr Functional Description A key to validate the function of other keys printed in blue on the panel. This key alone uses the internally lit system. When lit, the key is in the valid status (Shift status). Moreover, when the key is lit together with the <REMOTE> display on the indicator, it signifies the remote status via GPIB or RS-232C. Pressing the key in this state can switch the mode into the local mode. A key to switch channels of control target. When units of the same type are used, the key switches channels as follows every time it is pressed. CH1 CH2 CH1 & CH2 CH1 On the other hand, when units of different types are used, the key switches channels as follows every time it is pressed. CH1 CH2 CH1 A key to enable selection of parameters of the unit. Every time the key is pressed, the following items are selected. [Optical sensor] REF DATA,CAL FACTOR,AVERAGE,MOD FREQ, INTERVAL,BANDWIDTH,DISP UNIT,DISP BLANK [Light source] MOD FREQ,DISP UNIT,ATT The key enables selection of the main unit functions (system functions) in the Shift status. Every time the key is pressed, the following items are selected. REMOTE INTERFACE,GPIB ADDRESS, RS-232C BAUDRATE,RS-232C STOP BIT, RS-232C PARITY BIT,RS-232C CHARACTER, DISPLAY BRIGHTNESS,BUZZER,DATE,TIME 2 Nomenclature and Function Ref Rel A key to be used only when the optical sensor is used. Every time the key is pressed, measurement of the relative value (RELATIVE measurement) is conducted with the value measured at that time used as the reference value. Pressing the key in the Shift status causes measurement of the relative value (REFERENCE measurement) is conducted with the REF LEVEL for which parameter is set or the value measured of the other optical sensor used as the reference value. Cal dbm W A key to be used only when the optical sensor is used. Every time the key is pressed, the unit of representation switches between dbm and W. When the key is pressed in the Shift status, a value minus CAL FACTOR for which parameters are set is displayed. 2-9

40 Section 2 Nomenclature and Function Appl Run/Stop Auto Manu Restart Max Min λ Select A key to enable selection of set application items. Every time the key is pressed, the following items are selected. [Optical sensor] (or NO DATA) [Light source] (or NO DATA) A key to be used only when the optical sensor is used. Every time the key is pressed, the measurement range setting switches between automatic range setting and fixed range setting. When the key is pressed in the Shift status, the function to record the measured values can be executed and suspended. A key to be used only when the optical sensor is used. Every time the key is pressed, the maximum and minimum values measured so far and the difference between the two values are indicated. When the key is pressed in the Shift status, the data stored are cleared, followed by start of recording of new maximum and minimum values and the difference between the two values. A key to set the calibrated wavelength (optical frequency) when the optical sensor is used or set the optical frequency (wavelength) of radiation when the light source is used. (However, the key is not available for a single-wavelength light source that does not have the optical frequency (wavelength) variable function.) A key to enable switching of selection items available for setting at the time of parameter or system setting. A key to enable move of the input digit at the time of parameter or system setting. The parameter details can be checked (the parameter viewing function) when the setting is other than the parameter or system setting. Pressing the key causes sequential switching of items of display. A key to enable increase or decrease of numerical values at the time of parameter or system setting. Enter A key to establish setting and terminate the setting status at the time of parameter or system setting. 2-10

41 2.6 Front Panel of Plug-in Unit 2.6 Front Panel of Plug-in Unit Optical Sensor (MU931311A/1421A) MU931311A 2 [1] Zero set key [2] Analog signal output connector [3] Optical connector [4] Drawing lever [5] Cap [1] Zero set key Used to remove the electrical offset of the light intercepting circuit Zero Set [2] Optical connector Connects the optical fiber cable to input measuring beam. 3.7 Connection of Optical Fiber Cable Nomenclature and Function Caution Never input light above the rated maximum input value. This may cause permanent damage to the equipment such as a burnout of the optical receiver and ferrule end panel. [3] Analog signal output connector An SMA connector for analog output with an output range between 0 and 2 V and output impedance of approximately 1 kω. This connector outputs a voltage proportionate to the optical input. The connector outputs a voltage of approximately 2 V when light at the full scale level of each measurement range is intercepted.* *For example, this means optical input of -10 dbm when the range is set at 10 dbm. Caution The analog signal output connector is exclusively for output. When signals are input by mistake, this may cause damage to the Device or the signal source connected. Do not pull the cord while the cord remains inserted to the analog signal output connector. This may cause damage to the connector or the internal circuit. 2-11

42 Section 2 Nomenclature and Function Point Analog signals are directly output without correction of the wavelength sensitivity of the signals from the light intercepting circuit of the optical sensor. For this reason, the relationship between the level indication and the voltage output merely serves as a guideline and they do not necessary match each other. However, this function will prove useful to observe changes that take place more quickly than the display of numerical values on the main unit is able to indicate. [4] Drawing lever Incorporates a locking mechanism to be used when units are mounted on the main unit. Pinch the lever and draw it out to remove the lever. 3.3 Mounting and Removal of Plug-in Unit [5] Cap A cap for optical connector protection and shading from light. 2-12

43 2.6 Front Panel of Plug-in Unit Optical Sensor (MU931422A/31A) MU931422A [1] Zero-setting key 2 [2] Analog signal output connector [3] Connector adapter [4] Pulling-lever [5] Metallic cap Nomenclature and Function [1] Zero-setting key Used for removing an electric error from the optical receiving circuit. [2] Analog signal output connector It is SMA connector for the analog-output having the output range between about 0 and 2 V and having the output impedance of 1 kω. The electric power proportional to an optical input is output. When optical signal of a full-scale level is received* in each measurement range, roughly 2 V of electric power is output. * For instance, it indicates the case when the optical signal 10 dbm is input in 10 dbm range. CAUTION The analog signal output connector is only for the output. This equipment or the connected signal source might be damaged if the signal is input by mistake. Do not unplug the cord while it is connected to the analog signal output connector. The connector, the internal circuit and other equipment may be damaged. 2-13

44 Section 2 Nomenclature and Function Point Analog signal output is directly output to the optical sensor without correcting the wavelength sensitivity for the received optical circuit signal. Therefore, the relation between the displayed level and the output voltage is a rough guide, and is not necessarily equal. However, it is effective in observing the more minute change than the numeric value change displayed in the main unit. [3] Pulling-lever The lever has a lock mechanism when the sensor adapter is installed in the main unit. When removing it, pull it out holding the lever. [4] Connector adapter To input a measured optical signal, connect the optical fiber cable. The connector adapter can be replaced. Connector adapters (optional) compatible with connectors other than FC are available. Refer to ordering information. CAUTION Never input an optical signal larger than the maximum input ratings. There is danger of causing permanent damage to the equipment by burning the optical signal receiving instrument, etc. [5] Metallic cap This is a cap used for optical connector protection, dust-proofing, and shading. 2-14

45 2.6 Front Panel of Plug-in Unit Sensor Adapter (MU931001A/02A) MU931001A [1] Zero-setting key 2 [2] Analog signal output connector [3] Connector [4] Pulling-lever [1] Zero setting key Used for removing an electric error from the optical receiving circuit. Nomenclature and Function [2] Connector Connects a special optical sensor connecting cable. CAUTION Do not connect other than the specialized connection cable, or allow the connector to touch any metallic objects. There is a possibility of permanent damage to the equipment. Do not unplug the special connection cable while it is connected or the connector and the internal circuit, and other equipment may be damaged. [3] Analog signal output connector The connector is SMA connector for the analog-output having an output range between approximately 0 and 2 V and having the output impedance of 1 kω. Electric power is output proportional to the optical input. When a full-scale optical signal is received* in each measurement range, electric power of roughly 2 V is output. * For instance, when the optical signal 10 dbm is input in 10 dbm range. 2-15

46 Section 2 Nomenclature and Function CAUTION The analog signal output connector is only for the output. This equipment or the connected signal source might be damaged if the signal is input by mistake. Do not unplug the cord while it is connected to the analog signal output connector. The connector, the internal circuit and other equipment may be damaged. Point Analog signal output is directly output to the optical sensor without correcting the wavelength sensitivity for the received optical circuit signal. Therefore, the relation between the displayed level and the output voltage is a rough guide, and is not necessarily equal. However, it is effective in observing the more minute change than the numeric value change displayed in the main unit. [4] Pulling-lever The lever has a lock mechanism when the sensor adapter is installed in the main unit. When removing it, pull it out holding the lever. 2-16

47 2.6 Front Panel of Plug-in Unit Optical Sensor (MA9331A/32A/33A) For MA9331A [1] Connector adapter 2 For MA9332A/33A [2] Metallic cap Nomenclature and Function 12 [1] Connector adapter To input a measuring optical signal, connect the optical fiber cable. The connector adapter can be replaced. Connector adapters (optional) compatible with connectors other than FC are available. Refer to ordering information. CAUTION Never input an optical signal larger than the maximum input ratings. There is danger of causing permanent damage to the equipment by to burning the optical signal receiving instrument, etc. [2] Metallic cap This is a cap used for optical connector protection, dust-proofing, and shading. 2-17

48 Section 2 Nomenclature and Function Light Source MU952501A [1] Optical output ON/OFF key [2] Optical connector (located in the connector cap) [3] Drawing lever [1] Optical output ON/OFF key Used to switch the optical output ON and OFF Optical Output ON/OFF [2] Optical connector (located in the connector cap) Connects optical fiber cable in order to extract radiation. 3.7 Connection of Optical Fiber Cable [3] Drawing lever Incorporates a locking mechanism to be used when units are mounted on the main unit. Pinch the lever and draw it out to remove the lever. 3.3 Mounting and Removal of Plug-in Unit 2-18.

49 Section 3 Before Use This chapter summarizes matters you are advised to learn before you start using the Device. It is recommended that you read through this chapter at least once since this chapter provides descriptions of matters that require attention in order to ensure safety during the Device use and avoid failures. 3.1 Installation Installation Conditions Installation Environment Power Source Voltage and Frequency Connecting the Power Cord Mounting and Removal of Plug-in Unit Connecting Specialized Optical Sensor Connection Cable Measuring High-Power Output Laser Safety Connection of Remote Interlock Connector Optical Output Modifier Key Switch Connection of Optical Fiber Cable Replacement of Optical Connector Replacement of Fuse Others Before Use 3-1

50 Section 3 Before Use 3.1 Installation Installation Conditions Install the Device on a level surface Installation Environment The Device operates in the temperature range from 0 to 50 C. However, it is advised not to use the Device under environments such as the ones listed below as this may result in failure. Places subject to vibrations Humid and dusty places Places with gradient Places exposed to direct sunlight Places that may be exposed to active gases Places to experience drastic temperature fluctuations Moreover, moving the Device to a place of high temperature after using it for many hours in a place of low temperature may cause condensation in the Device interior. Turning the power source ON in this status may cause a failure such as short circuit. In a case like this, turn the power source ON after thoroughly drying the Device. The Device incorporates a cooling fan inside. Accordingly, place the Device at least 10 cm away from an obstacle such as the wall and peripheral equipment to ensure excellent ventilation of air. 3-2

MT9810A Optical Test Set Operation Manual

MT9810A Optical Test Set Operation Manual MT9810A Optical Test Set Operation Manual Seventh Edition Read this manual before using the equipment. Keep this manual with the equipment. ANRITSU CORPORATION Document No.: M-W1482AE-7.0 To prevent the

More information

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications OPTICAL SPECTRUM ANALYZER 600 to 750 nm GPIB High Performance for DWDM Optical Communications The is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 600 to 750 nm wavelength

More information

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved. SLS-50 Stabilized Laser Source User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS USER MANUAL 27 Full HD Widescreen LED Monitor L27ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E USER MANUAL 27 Full HD Widescreen LED Monitor L270E TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215ADS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL Full HD Widescreen LED Monitor L215IPS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215IPS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL DVBus 8350-16 and 8350-4 Multiplexer and demultiplexer assemblies for 16-4 video channels, with bidirectional audio and data USER MANUAL 1. Description. Indicators and system connections DVBus 8350 systems

More information

PSM-003. Micro Polarization Controller/Scrambler. User Guide

PSM-003. Micro Polarization Controller/Scrambler. User Guide PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website

More information

VGA to DVI Extender over Fiber SET

VGA to DVI Extender over Fiber SET VGA to DVI Extender over Fiber SET Model #: FO-VGA-DVI 2011 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview

More information

Light Source. Specification & User Manual

Light Source. Specification & User Manual Light Source Specification & User Manual Page 1 of 11 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 22 Class Slim HD Widescreen Monitor L215DS USER MANUAL 22" Class Slim HD Widescreen Monitor L215DS TABLE OF CONTENTS 1 Getting Started Package Includes Installation 2 Control Panel / Back Panel Control Panel Back Panel 3 On Screen Display 4 Technical

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and

More information

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG ENGLISH FRANCAIS SPANISH DEUTSCH Subwoofers OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG Titan 5.6 Titan 7.6 MK2 Titan 11.6 MK2 Titan 15.6 MK2 MOSSCADE BP 306-94709 Maisons-Alfort

More information

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

USER MANUAL. 27 2K QHD LED Monitor L27HAS2K USER MANUAL 27" 2K QHD LED Monitor L27HAS2K TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Troubleshooting 6 Safety Info & FCC warning 1 GETTING

More information

.Power Distribution Center. PD-1. Instruction Manual

.Power Distribution Center. PD-1. Instruction Manual .Power Distribution Center. PD-1 Instruction Manual www.datavideo-tek.com 1 Contents Warnings and Precautions... 3 Warranty... 4 Standard Warranty... 4 Two Year Warranty... 4 Disposal... 4 Packing List...

More information

Product Operation Manual

Product Operation Manual Product Operation Manual VL-FTX FORWARD TRANSMITTER MODULE Ver 1.1(Doc#01-02-008) VALE SYSTEMS INC. 10400 Overland Road #408 Boise, ID 83709-1449,USA Tel: 208.935.6317Fax: 208.935.6234 All rights reserved

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

MANUAL ENGLISH Core Club Ordercode: D2314

MANUAL ENGLISH Core Club Ordercode: D2314 MANUAL ENGLISH Core Club Ordercode: Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Unpacking Instructions... 2 Safety Instructions... 2 Operating

More information

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications March 2006 Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical

More information

USER MANUAL Full HD Widescreen LED Monitor L236VA

USER MANUAL Full HD Widescreen LED Monitor L236VA USER MANUAL 23.6 Full HD Widescreen LED Monitor L236VA TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630 User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630 Preface Read this user manual carefully before using this product. Pictures shown in this manual

More information

Assembly Level Service Guide

Assembly Level Service Guide Assembly Level Service Guide This guide describes how to service the Agilent 53150A, 53151A, and 53152A Microwave Frequency Counters. The information in this guide applies to instruments having the number

More information

opengear OPG-1L 50 MHz-2.3 GHz

opengear OPG-1L 50 MHz-2.3 GHz MODEL opengear OPG-1L 50 MHz-2.3 GHz RF FIBER OPTIC LINK EMCORE s opengear OPG-1L s are optimized to perform in the 50 MHz to 2.3 GHz frequency range providing transparent signal transport for satellite

More information

Golf ball tracker. Instruction manual

Golf ball tracker. Instruction manual Golf ball tracker Instruction manual General Intended use The Prazza golf ball finder is intended for use on the golf course only and should never be used inside the home or any other enclosed environment.the

More information

NS-3 RF Noise Source Operation Manual

NS-3 RF Noise Source Operation Manual RF Noise Source Operation Manual Version 2.04 June 3, 2016 SPECIFICATIONS Frequency... Maximum output level... Output flatness... (at max output level) Impedance... Displayed level... Repeatability...

More information

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number: USERS GUIDE MCX-HTS HDMI to 3G SDI Converter i Manual Number: 151226 SAFETY INSTRUCTIONS Please review the following safety precautions. If this is the first time using this model, then read this manual

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Users Manual. Stroboscope. September 2014

Users Manual. Stroboscope. September 2014 820-2 Stroboscope Users Manual September 2014 2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

More information

Litile34 OPERATION MANUAL

Litile34 OPERATION MANUAL Litile34 OPERATION MANUAL Seamless Tiled Panel Wall Solution for Large Area Digital Signage Display (1st Edition 3/25/2009) All information is subject to change without notice. Approved by Checked by Prepared

More information

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements MN9320A Optical Channel Drop Unit Independent Test Access Tool for Comprehensive DWDM Measurements MN9320A Access to DWDM Channels and Traffic at One Location The technique of Dense Wavelength Division

More information

TVAC20000 User manual

TVAC20000 User manual TVAC20000 User manual Version 01/2010 Original English user manual. Keep for future use. 10 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the

More information

K3NX Process Meter OPERATION MANUAL

K3NX Process Meter OPERATION MANUAL Cat.No. N90 E1 1 K3NX Process Meter OPERATION MANUAL K3NX Process Meter Operation Manual Produced January 1998 Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472 Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Concert Series brings excitement

More information

SATRI AMPLIFIER AMP-51R. Owner s Manual

SATRI AMPLIFIER AMP-51R. Owner s Manual SATRI AMPLIFIER AMP-51R Owner s Manual contents SAFETY INSTRUCTIONS 4 INTRODUCTION 6 OVERVIEW (FRONT PANEL) 8 OVERVIEW (REAR PANEL) 9 OVERVIEW (REMOTE CONTROL) 1 1 OPERATION 12 TROUBLESHOOTING 13 SPECIFICATION

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

USER MANUAL. 28 4K Ultra HD Monitor L28TN4K USER MANUAL 28" 4K Ultra HD Monitor L28TN4K TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety Info &

More information

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s

More information

Register your product and get support at www.philips.com/welcome SWW1890 User manual Contents 1 Important 4 Safety 4 English 2 Your Philips Wireless HD Net Connect 5 What is in the box 5 3 Overview 6

More information

Winmate Communication INC.

Winmate Communication INC. 20.1 Military Grade Display Model: R20L100-RKA2ML User s Manual Winmate Communication INC. May, 2011 1 IMPORTANT SAFETY INSTRUCTIONS Please read these instructions carefully before using the product and

More information

PIM Master. Maintenance Manual

PIM Master. Maintenance Manual Maintenance Manual PIM Master MW8208A, MW8209A, MW8219A Passive InterModulation Analyzer MW8208A: 869 MHz to 894 MHz MW8209A: 925 MHz to 960 MHz MW8219A: 1930 MHz to 1930 MHz and 2110 MHz to 2155 MHz Anritsu

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-001 PRODUCT REVISION: 1 TNP100 Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are

More information

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630 User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630 Preface Read this user manual carefully before using this product. Pictures shown in this manual are for reference

More information

Wired to Wireless Camera Converter

Wired to Wireless Camera Converter Wired to Wireless Camera Converter Instruction Manual English Version 1.0 MODEL: WL401BNC www.lorexcctv.com Copyright (c) 2006 LOREX Technology Inc. Thank you for purchasing the 2.4 GHz Wireless Camera

More information

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234 2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234 Please read this manual thoroughly before operating this system OPERATING INSTRUCTIONS 03/02 1 SAFETY INSTRUCTIONS CAUTION! RISK OF ELECTRIC SHOCK. DO

More information

ENGLISH Antenna Distributor

ENGLISH Antenna Distributor MANUAL ENGLISH Antenna Distributor V1 Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Safety Instructions... 2 Operating Determinations... 4 Connection

More information

PL2410W LCD Monitor USER'S GUIDE.

PL2410W LCD Monitor USER'S GUIDE. PL2410W LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Operating Instructions

Operating Instructions Model No.: TESTER-H01 Operating Instructions Thanks for purchasing our product. Please be sure to read this instruction manual carefully before using our product. Contents HDMI Signal Generator...1 Product

More information

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19 No. IB028911 Nov. 2016 User s Manual Insulation Resistance Tester TOS7200 1. Preface 11 2. Preparation 14 3. Safety Precautions during Testing 19 4. Basic Operation 23 5. Using Terminals and Connectors

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

Fusion 120 Zoom. User Manual. Order code: EQLED068

Fusion 120 Zoom. User Manual. Order code: EQLED068 Fusion 120 Zoom User Manual Order code: EQLED068 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

KHT 1000C HV-Probe Calibrator. Instruction Manual

KHT 1000C HV-Probe Calibrator. Instruction Manual KHT 1000C HV-Probe Calibrator Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject

More information

Model AQ Gbit/s Optical Receiver

Model AQ Gbit/s Optical Receiver User s Manual Model 810518803 AQ2200-631 10Gbit/s Optical Receiver Yokogawa Electric Corporation IM 810518803-01E 1st Edition Introduction Thank you for your purchasing of this AQ2200-631 10Gbit/s Optical

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2 User Manual PS-684 All Rights Reserved Version: UHBT70P_2016V1.2 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different model

More information

NI PXI/PXIe-2543 Specifications

NI PXI/PXIe-2543 Specifications NI PXI/PXIe-2543 Specifications 6.6 GHz Dual 4 1 Terminated Solid State Multiplexer (Dual SP4T) This document lists specifications for the NI PXI/PXIe-2543 (NI 2543) multiplexer module. All specifications

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer Kramer Electronics, Ltd. USER MANUAL Model: VA-14 4x1 Balanced Audio Mixer Contents Contents 1 Introduction 1 2 Getting Started 2.1 Quick Start 1 1 3 Overview 3 4 Your VA-14 4x1 Balanced Audio Mixer 4

More information

CU103 User Manual. Contents

CU103 User Manual. Contents [Note] The Photos of Light Engine and Control Unit in this manual are for reference only. The items may be different in actual package. Contents 1. PRECAUTIONS... 2 2. PACKAGE CONTENT... 4 3. PORT DESCRIPTION...

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Important Safety Precautions Make sure to read this user s guide and follow the procedures below prior to screen operation.

More information

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual Table of Contents 1 Introduction... 1 2 Warnings... 2 3 Getting Started... 2 3.1 Parts List...

More information

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A Hand-held Design Brings Peak Performance to the Field Optical Multimeter 2 Designed for manipulation by fingertips The Optical Multimeter is designed for use in the field, with small size, light weight

More information

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE MANUAL PART NUMBER: 400-0108-002 PRODUCT REVISION: 1 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE INTRODUCTION Altinex appreciates your purchase of the Line Driver. We are sure you will find

More information

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

17 19 PROFESSIONAL LCD COLOUR MONITOR ART 17 19 PROFESSIONAL LCD COLOUR MONITOR ART. 41657-41659 Via Don Arrigoni, 5 24020 Rovetta S. Lorenzo (Bergamo) http://www.comelit.eu e-mail:export.department@comelit.it WARNING: TO REDUCE THE RISK OF FIRE

More information

User Instructions. 16 SCB Sync Station.

User Instructions. 16 SCB Sync Station. User Instructions 16 SCB Sync Station Contents Overview... 1 Specifications... 1 Compliance and approvals... 2 Safety instructions... 3 Set up... 4 How to charge multiple devices... 4 How to synchronize

More information

LED Spot 300W. Please read this user manual before your operation

LED Spot 300W. Please read this user manual before your operation LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark

More information

Electric Motorized Projection Screen PowerMax Tension Series

Electric Motorized Projection Screen PowerMax Tension Series Electric Motorized Projection Screen PowerMax Tension Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen

More information

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE MANUAL PART NUMBER: 400-0133-001 PRODUCT REVISION: 0 CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION...

More information

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen

More information

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM PTY. LTD A.B.N. 83 003 020 504 OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM Document

More information

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical power of laser

More information

OptEnet OC48 Regenerator Module User Manual

OptEnet OC48 Regenerator Module User Manual OptEnet OC48 Regenerator Module User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................

More information

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF - 1 - WELDING INVERTER PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF OPERATING MANUAL PEGAS 160-200 T PULSE manual EN 06 -2- CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL

More information

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

2.4 GHz WIRELESS SURVEILLANCE SYSTEM 2.4 GHz WIRELESS SURVEILLANCE SYSTEM Operating Instructions Tested Comply With FCC Standards Model # TBM-18 BEFORE OPERATING THIS PRODUCT, READ, UNDERSTAND, AND FOLLOW THESE INSTRUCTIONS. Be sure to save

More information

VLHDMIEXTFIB_2017V1.0

VLHDMIEXTFIB_2017V1.0 User Manual VLHDMIEXTFI ll Rights Reserved Version: VLHDMIEXTFI_2017V1.0 Preface Read this user manual carefully before using the product. Pictures are shown in this manual for reference only, different

More information

Operating Instructions

Operating Instructions Operating Instructions SDI Input board Model No. AV-HS04M1 РУССКИЙ FRANÇAIS DEUTSCH ENGLISH ESPAÑOL ITALIANO Before operating this product, please read the instructions carefully and save this manual for

More information

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ Model #: VGA-C5A-SET 2010 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc.

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE MANUAL PART NUMBER: 400-0430-001 1-IN 1-OUT LINE DRIVER WITH UALIZATION + AUDIO USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2 INSTALLATION...2

More information

3G/HD/SD-SDI to HDMI Converter

3G/HD/SD-SDI to HDMI Converter 3G/HD/SD-SDI to HDMI Converter Model #: 3G/HD/SD-SDI to HDMI Converter 2010 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products.

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Electric Wall/Ceiling Projection Screen Saker Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Series User s Guide Electric Wall/Ceiling Projection Screen Saker Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s Black

More information

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras Eng Installation Instructions F D E NL I IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before

More information

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide In-Ceiling Electric Motorized Front Projection Screen Evanesce Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The

More information

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0 User Manual CVA3 All Rights Reserved Version: CVA3_2016V1.0 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different model and specifications

More information

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE MANUAL PART NUMBER: 400-0133-002 CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION... 2 CLEANING... 2 FCC / CE NOTICE...

More information

VideoSplitter HDMI 4K PT

VideoSplitter HDMI 4K PT VideoSplitter HDMI 4K PT 4K HDMI Splitter Pigtail Type Installation and Operation Manual 10707 Stancliff Road Houston, Texas 77099 Phone: (281) 933-7673 tech-support@rose.com LIMITED WARRANTY Rose Electronics

More information

1X4 HDMI Splitter with 3D Support

1X4 HDMI Splitter with 3D Support AV Connectivity, Distribution And Beyond... VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES 1X4 HDMI Splitter with 3D Support Model #: SPLIT-HDM3D-4

More information

RemotePoint. Navigator. User s Manual VP4150

RemotePoint. Navigator. User s Manual VP4150 RemotePoint Navigator User s Manual VP4150 LASER Safety Statement CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9110 Portable Airborne Particle Counter (particle counter). This guide will help you

More information

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model Designed in Germany 2017 PureLink GmbH All rights reserved. VersionV1.0 Preface Read this user manual carefully before using this product. Pictures shown in

More information

Fiber Optic Meter Fiber Optic Source

Fiber Optic Meter Fiber Optic Source FOM/FOS Fiber Optic Meter Fiber Optic Source Warning To avoid injury: do not service the FOM or FOS unless you are qualified to do so. The service information provided in this document is for the use of

More information

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit User Manual L-1SDI-SFE-TX/RX Table of Contents Table of Contents---------------------------------------------------------------------------------1

More information

CM-S23349SV. Vari-Focal IR Bullet Camera

CM-S23349SV. Vari-Focal IR Bullet Camera Vari-Focal IR Bullet Camera User s Guide CM-S23349SV SAFETY PRECAUTIONS WARNING 1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause

More information