1 Manual Simrad IS80 Wind Instrument WI80 English A brand by Navico - Leader in Marine Electronics

2 Manual Simrad IS80 Wind Instrument WI80 English Document no: Revision: B Date: December 2008 The original language for this document is English. In the event of any discrepancy between translated versions and the English version of this document, the English document will be the official version. To the best of our knowledge, the content in this publication was correct at the time of printing. As we are continuously improving our products we retain the right to make changes to the product and the documentation at any time. Updated manuals are available from our website and are free to download. Copyright 2008 by Navico Holding AS.

3 About this manual This manual is a reference guide for installing and operating the Simrad WI80 Instrument. The manual does not include installation procedures for sensors that can be connected to the system. In this manual, names of modes and keys are written in boldface (e.g. User setup, Mode/Setup key). In the illustrations throughout the manual the following symbols are used: Time indication (1, 3, 5 or 10 seconds) Single key press with time indication + Combined key press with time indication A. 1 A.2 Repeated key presses on single key 0FFS 1 s Automatic change in LCD readings with time indication (no key presses required) Important text that requires special attention from the reader is emphasized as follows: Used to draw the reader s attention to a comment or some important information. When necessary, used to warn personnel they should proceed carefully to prevent risk of injury and/or damage to equipment. 2 WI80 Wind indicator

4 Contents 1 Introduction... 5 General information...5 Instrument layout Installation... 7 Location of the unit...7 Panel mounting...7 Cable connection and interface...8 Securing the cables...9 Interconnecting instruments...9 Installation setup Operation Turning the WI80 on Using the keys Selecting active display mode Bargraph Backlighting Error Alarm Maintenance Operation flow chart Changing the default settings General Display damping Wind speed alarm Wind shift alarm WI80 Wind indicator 3

5 Speed units Light bank selection Spare parts Spares and auxiliaries SimNet cables and accessories Specifications Technical specifications Dimensional drawing WI80 Wind indicator

6 1 Introduction General information The WI80 Instrument presents you with relevant wind information on a combined analog and digital display. Adjustable backlight for night operation is provided as well as adjustable intensity on the LED displays for operation in sunshine. Instrument layout The WI80 display includes bargraph, dial with pointer and LED display. Modes of operation and units for measure are indicated by monitor diodes. The instrument is operated by 2 keys. These are used to switch between display modes, to set parameter values and to adjust background illumination. The dial is divided into 360. Hence, when the wind is coming from port in true and relative modes, the image of the starboard dial should apply. Introduction 5

7 6 Introduction Blank page

8 2 Installation Location of the unit The WI80 should be mounted with special regard to the unit s environmental protection, temperature range and cable length. Refer to the Specifications chapter. Avoid mounting the unit where it is easily exposed to sunlight, as this may unintendedly overheat the unit. Panel mounting The mounting surface must be flat and even to within 0.5 mm Drill 4 mounting holes and make a panel cut-out according to the drilling template included in the package Use the supplied self tapping screws to secure the unit to the panel Apply the front corners Do not over-tighten the screws! Installation 7

9 1 Cable connection and interface Signal input, network and power supply are wired to the enclosed terminal block that is to be plugged in on the rear side. The instrument is delivered with a 0.3 m SimNet cable with a standard SimNet plug in both ends. One plug must be cut off and the wires connected to terminals 3 through 6 according to the color codes shown below. TERMINAL NO SIGNAL TYPE COLOR 1 GND - Supply - 2 VCC + Supply 12-24V DC - 3 SimNet - H NMEA2000 channel Yellow 4 SimNet - C NMEA2000 channel Black 5 SimNet - L NMEA2000 channel Blue 6 SimNet - S NMEA2000 channel Red 7 RS485 A NMEA0183 (Rx+) - 8 RS485 GND No connection - 9 RS485 B NMEA0183 (Rx-) - Any voltages other than those specified in the product specification, page 29, may cause damage to the instrument. Data on the NMEA0183 port will be converted to SimNet/ NMEA2000 format and distributed to other instruments that are interconnected on the SimNet network. 8 Installation

10 Securing the cables Use the eclosed tie wrap to secure the cables to the instrument. Interconnecting instruments Interconnect a series of instruments by using a SimNet power cable with termination and T-joiners as illustrated below. Instrument Supply 12-24V SimNet Supply (Red disk) 12V SimNet T-joiner SimNet T-joiner SimNet T-joiner If the instruments are connected to other SimNet compatible products, refer to the manual for those products. Use only 12V as SimNet supply! Installation 9

11 Installation setup SimNet, NMEA0183 and Demo mode are selectable inputs on the WI80. After installation, the system must be configured to read the preferred input signal before the instrument is ready for use. The Installation Setup is accessed as shown in the illustration. MAIN S - RELATIVE - TRUE - GEO- GRAPHIC s 5 s INSTALLATION - INPUT SIGNAL - OFFSET As an example the illustration below shows the LED reading when the input type is changed from SimNet to Demo. MAIN S - RELATIVE - TRUE - GEO- GRAPHIC 10 s + 5 s + INSTALLATION - INPUT SIGNAL - OFFSET A A s Refer also to the Operation flow chart in the Operation section. The pointer position will change accordingly as shown in the table. SIGNAL INPUT LCD POINTER SimNet 5 1 NMEA183 Demo 10 Installation

12 10 s + 5 s + Offset adjustment Any residual error in the apparent wind angle can be adjusted manually by entering an offset angle. A positive value (no sign) indicates starboard offset angle, while an offset angle to port is indicated with negative value (negative sign). The illustration below illustrates the required key presses to offset the angle to Range: +/-99 Default: 0.0 INSTALLATION - INPUT SIGNAL - OFFSET - RESET 0FFS 1 s s MAIN S - RELATIVE - TRUE - GEO- GRAPHIC +/ Starboard (+) 1 s Port (-) + Local SimNet reset Under the SimNet input, select the L.res window and press both keys to save the local reset of SimNet. Installation 11

13 12 Installation Blank page

14 3 Operation Turning the WI80 on WI80 has no power key, and will be running as long as power is connected. When power is applied to the system the display will indicate the active mode as shown in the table. Initial LED After 1 second POINTER Relative True Geographic Actual wind speed according to active mode Wind direction according to active mode After approximately econds the instrument is operative. Default: Relative wind Before the instruments is ready to operate the default settings should be checked and changed if other values are preferred. Refer to the Changing the default settings chapter. Using the keys The instrument is operated by the 2 keys on the front. They are used to switch between display modes, to set values and to adjust the illumination as illustrated in the table on the next page. Key presses or key combinations not indicated in the table have no effect. Refer also to Operation flow chart. Operation 13

15 KEY KEY PRESS DISPLAY /ACTION S Short Go to next main display Go to next Setup mode ec. Switch to User Setup Switch to main display Short Increase light level ec. + Short 10 sec. Enter Installation Setup Select parameter Adjust parameter None / Change to next digit Save setting and return to Setup parameter 5 sec Return to main display Time out from User Setup is 10 sec. Time out from Installation Setup is 5 min. REL GEO TRUE Selecting active display mode The WI80 can display relative, true and geographic wind speed and direction. The instrument will scroll through these displays by pressing the Mode/Setup key. Active mode is indicated by a lit diode in the display. To calculate true wind, speed data input is required. To calculate geographic wind, both speed and heading data input is required. If these data are not available, no value will be displayed in the LED when True or Geographic wind is selected. 14 Operation

16 Bargraph The bargraph operates as a releative wind gust indicator. The direction of the wind gust is displayed as shown in the table below. WIND DIRECTION BARGRAPH 1 lit diode per 1m/s increased wind speed, starting from the right side, max 10 diodes are lit PORT STBD lit diodes per 2m/s increased wind speed, starting from both sides, max 10 diodes on each side PORT STBD lit diode per 1m/s increased wind speed, starting from the left side, max 10 diodes are lit PORT STBD lit diodes per 2m/s increased wind speed, starting from center going to both sides. PORT STBD Operation 15

17 Backlighting The backlighting is adjusted by pressing the Light key when the instrument is in normal operation. Current light setting will be indicated with the right LED digit. The light setting affects the diodes, the digital display and the backlight as shown in the table: LIGHT LEVEL DIODES AND DISPLAY BACKLIGHT 0 Low Off 1-7 Steps Steps 8 Medium Off 9 High Off Level 8 and 9 are for bright daylight. The instrument will return to normal operation 1 second after the last key press. Range: 0-9 Default value: 2 If several instruments are connected via SimNet, the instruments can be grouped in different light banks. Changing the backlight settings on one of the instruments will affect all instruments in the group. Refer to Light bank selection in Changing the default settings chapter. Error Alarm In the event the error indicator is lit, the instrument is not operable and service/repair is required. 16 Operation

18 Maintenance The IS80 instruments are repair by replacement units, and the operator is therefore required to perform only a very limited amount of preventive maintenance. If the unit requires any form of cleaning, use fresh water and a mild soap solution (not a detergent). It is important to avoid using chemical cleaners and hydrocarbons such as diesel, petrol etc. If a weather cover is available this should be put on when the unit is not in use.operation flow chart Operation 17

19 Operation flow chart INSTALLATION Input Type - SimNet - NMEA Demo Offset - Adjust setting Reset - Local SimNet reset 10 s + 5 s + 5 min MAIN S Relative wind True wind Geographic wind 10 s USER Display Damping - Damping 0 - Damping 1 - Damping 2 - Damping 3 Wind Speed Alarm Limit - Adjust limit Wind Shift Alarm Limit - Adjust limit Speed Unit - m/s - kts - mph - km/h - bu Light Bank Selection - Simrad - Gr 1 - Gr 2 - Gr 3 - Gr 4 - Gr 5 - Gr 6 - None 18 Operation

20 4 Changing the default settings General The factory default settings may all be changed in the User setup, accessed as shown in the illustration. Detailed illustrations for the different settings are shown on the following pages. Refer also to the Operation flow chart in the Basic Operation chapter. MAIN S - RELATIVE - TRUE - GEO- GRAPHIC USER - DISPLAY DAMPING - WIND SPEED ALARM - WIND SHIFT ALARM - SPEED UNIT - LIGHT BANK Display damping The damping factor indicates how fast the display will respond to changes in wind readings. The setting affects both the LCD and the pointer. The higher the damping factor the more stable display reading on the instrument. Range: 0-3 Default: 0 The illustration below shows how to change the Damping level from 0 to 2. MAIN S USER 1 s - RELATIVE - DISPLAY DAMPING - WIND SPEED ALARM A. 1 A TRUE - WIND SHIFT ALARM - GEO- GRAPHIC - SPEED UNIT - LIGHT BANK Changing the default settings 19

21 Wind speed alarm The wind speed alarm setting defines the maximum wind speed limit before an alarm is activated. The alarm is acknowledged by a short press on one of the keys. The range is defined by the selected speed unit: SPEED UNIT RANGE m/s kts mph km/h BEAU Default value: Maximum range for the selected speed unit. The illustration on next page shows how to use the keys to change parameter values. It applies also for the wind speed alarm adjust. The alarm is turned off by setting the value to A Changing the default settings

22 Wind shift alarm Observe the dot after the A. The wind shift alarm will monitor the wind angle. The reference angle is set when the alarm is turned on, and reset to present wind angle when an alarm is acknowledged by a short press on one of the keys. Range: 0-90 Default: 090 MAIN S USER - DISPLAY DAMPING - RELATIVE - TRUE - WIND SPEED ALARM - WIND SHIFT ALARM A GEO- GRAPHIC - SPEED UNIT - LIGHT BANK 4 1 s 4 + The alarm is turned off by setting the value to A.000 Changing the default settings 21

23 M/S KTS MPH KM/H BEAU Speed units Selection used to define which unit used for measuring wind speed. Active speed unit is indicated by a lit diode in the display. SPEED UNIT m/s LCD kts mph km/h BEAU Default value: SPd1 = m/s The illustration shows required key presses for changing speed units from m/s to mph. MAIN S - RELATIVE - TRUE USER - DISPLAY DAMPING - WIND SPEED ALARM - WIND SHIFT ALARM SP 1 SP 2 SP s - GEO- GRAPHIC - SPEED UNIT - LIGHT BANK 22 Changing the default settings

24 Light bank selection The light bank function is used to globally control light settings for a group of units that are connected via the SimNet network. By assigning several units to the same group, the light adjustment on one unit will be effective on the rest of the members in the same group. LIGHT BANK LCD POINTER BEEPS Simrad 1 Group 1 1 Group 2 1 Group 3 1 Group 4 1 Group 5 1 Group 6 1 None 1 Default value: Simrad MAIN S - RELATIVE USER - DISPLAY DAMPING - WIND SPEED ALARM + 1 s - TRUE - WIND SHIFT ALARM - GEO- GRAPHIC - SPEED UNIT - LIGHT BANK If you prefer one instrument to stay outside any group for independent light adjustment, you select none. Changing the default settings 23

25 24 Changing the default settings Blank page

26 5 Spare parts Spares and auxiliaries Part no. Description WI80 instrument head Mounting kit including: - 4 screws - 6 corners - 1 terminal block NMEA0183 Interface cable 2.5 m (8 ) SimNet cables and accessories Part. no. Description m (1 ) SimNet cable (SDC:0.3M) m (6.6 ) SimNet cable (SDC:02M) m (16.6 ) SimNet cable (SDC:05M) m (33 ) SimNet cable (SDC:10M) SimNet T-joiner (SDJ) (3p) SimNet Multijoiner (7p) SimNet Bulkhead T-connector SimNet cable gland SimNet protection plug SimNet termination plug m (6.6 ) SimNet power w/termination m (6.6 ) SimNet power w/o termination AT10 Universal NMEA0183 converter AT15 Active T-connector, IS SimNet cable protection cap Spare parts 25

27 Part. no Description SimNet cable to Micro C male Cable that connects a SimNet product to a NMEA2000 network SimNet cable to Micro-C female cable that connects a NMEA2000 product to SimNet SimNet cable, 5.5 m (18 ), with 1 plug 26 Spare parts

28 6 Specifications Technical specifications Power supply...12/24v DC (+30%, -10%) Power consumption...< 5W SimNet network load... 1 NL Input signals: NMEA2000/SimNet... 1 can channel NMEA0183:... 1 optoisolated RS485 channel Input mode selection:...nmea2000/simnet, NMEA0183, Demo mode NMEA0183 to SimNet converter:...when NMEA0183 is selected Weight: kg (1.21 lb) Material:...ASA/PC Luran S Color:... Black Display: Dial: Marking:...10 Illumination:... Adjustable in 10 steps Digital display:... Four 7-segment LEDs Environmental protection: Front... IP66 Back:... IP20 Safe distance to compass: Steering compass m (1.32 ft.) Stand-by/Emergency distance m (0.66 ft.) Temperature: Operating: to +70 C (+5 to +158 F) Storage: to +80 C (-40 to +176 F) Climate Max 95% RH:... Max 30 days per year Max 85% RH:... Remaining days Max 75% RH:... Average per year Specifications 27

29 Dimensional drawing 47 mm [1.86"] 21 mm [0.83"] 172 mm [6.78"] 10 mm [0.37"] 172 mm [6.78"] 152 mm [5.98"] 136 mm [5.35"] 136 mm [5.35"] 153 mm [6.02"] 28 Specifications

30 WI80 Manual EN, Doc.no

Manual. Simrad IS80 Heading Repeater HR80. English

Manual. Simrad IS80 Heading Repeater HR80. English Manual Simrad IS80 Heading Repeater HR80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Heading Repeater HR80 English Document no: 20223194 Revision:

More information

USER GUIDE FOR DATALINE-X RUDDER. Stowe Marine Ltd. Tel +44(0)

USER GUIDE FOR DATALINE-X RUDDER. Stowe Marine Ltd.   Tel +44(0) USER GUIDE FOR DATALINE-X RUDDER Stowe Marine Ltd. www.stowemarine.com Tel +44(0)1590 610071 Dataline-X Rudder Manual, Part Number 06027SM, Issue 2, Dec 1995. Warning The equipment to which this manual

More information

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano Entry Level Wind System Français Deutsch Nederlands Espagñol Italiano Entry Level Wind System Important Suitability: the Entry Level Wind System is only recommended for use on cruising boats up to 10.5m

More information

C-net WIND. User s Guide

C-net WIND. User s Guide C-net WIND User s Guide EMC Directive 89/336/EEC This product has been designed to be compliant with the above EMC Directive. Maximum performance and compliance with the EMC Directive can only be ensured

More information

OP50 Controller. User Guide ENGLISH.

OP50 Controller. User Guide ENGLISH. OP50 Controller User Guide ENGLISH www.simrad-yachting.com Wiring CAN BUS (NMEA 2000) A B C Male Micro-C drop cable 1.8 m (6 ft) cable Micro-C T-connector CAN BUS (NMEA 2000) backbone A C B C ¼¼ Note:

More information

NETWORK COMPASS USER MANUAL CONTENTS

NETWORK COMPASS USER MANUAL CONTENTS CONTENTS NETWORK COMPASS USER MANUAL GENERAL INTRODUCTION TO B&G NETWORK...2 INTRODUCTION TO NETWORK COMPASS...3 COMPASS DISPLAY UNIT...4 EXAMPLE SYSTEMS USING NETWORK COMPASS...4 INITIAL POWER-UP...5

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

0.56 4 Digital Blue LED Panel Meter (rescalable) User s Guide 0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide 2004-2009 Sure Electronics Inc. ME-SP037B_Ver1.0 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Table of Contents Chapter

More information

ALWAYS AT THE FOREFRONT OF TECHNOLOGY

ALWAYS AT THE FOREFRONT OF TECHNOLOGY ALWAYS AT THE FOREFRONT OF TECHNOLOGY Instruction Manual M A N U A L Simrad IS12 Data Instrument III IS12 Data 2001 Simrad Ltd The technical data, information and illustrations contained in this publication

More information

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx Displays 15.0 Open Frame Monitor Model Number: AND-TFT-150Bxx The AND-TFT-150Bxx 15.0 Open Frame Monitor series are rugged, high performance Industrial LCD Monitors, designed for commercial and industrial

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85   Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3 MoTeC MDD User Manual Contents Introduction... 1 Display...1 Mounting...1 Firmware Version...2 ADL Operation... 3 1. Full ADL Display...4 2. Gain Loss Layout for ADL...6 3. Large Numeric Layout for ADL...8

More information

IS15 Instruments General Manual

IS15 Instruments General Manual M A N U A L IS15 Instruments General Manual ALWAYS AT THE FOREFRONT OF TECHNOLOGY This page is intentionally left blank. 20220760H This manual is intended as a reference guide for operating and correctly

More information

FLAT DISPLAY TECHNOLOGY

FLAT DISPLAY TECHNOLOGY 15.0 Open Frame Monitor Model Number: LOF1506xx This product is RoHS compliant SPEC No.: SAS-1008002 Version: 0.0 Issue Date: September 6, 2010 1. Introduction: 1.1 About the Product The LOF1506xx 15.0

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any MRV366 Receiving Card Document Version: Document Number: V1.0.1 NS110100658 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Refrigerated incubators with thermoelectric refrigeration Model KT 53 Refrigerated incubators with thermoelectric refrigeration The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Multi-function Portable. HD LCD Monitor. User Manual

Multi-function Portable. HD LCD Monitor. User Manual Multi-function Portable HD LCD Monitor User Manual Product description: Thank you for purchasing our photography, broadcast color LCD Monitor kit. This product adopts proprietary digital signal processing

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B ) SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery

More information

S7H-DK S7H 7" High Bright Monitor Deluxe Kit

S7H-DK S7H 7 High Bright Monitor Deluxe Kit S7H-DK S7H 7" High Bright Monitor Deluxe Kit QUICKSTART GUIDE What s Included 1 x S7H Monitor 1 x Camera Shoe Mount 1 x Neoprene Sleeve 1 x Mini-XLR to P-TAP Cable 2 x DV Battery Plate 1 x DV Battery 1

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBF 1020 Constant climate chambers with large temperature / humidity range Model KBF 1020 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

LED Backlight for Technics amplifiers

LED Backlight for Technics amplifiers LED Backlight for Technics amplifiers Technics SE-A900S Technics SE-A900SM2 Technics SE-A909S Technics SE-A1000 Technics SE-A1000M2 Technics SE-A1010 Rev. 1.2 B Description The LED module is designed to

More information

LA1500R USER S GUIDE.

LA1500R USER S GUIDE. LA1500R USER S GUIDE www.planar.com The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights

More information

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 115 Cooling incubators with thermoelectric cooling Model KT 115 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

Entry Level Speed/Depth Display. English Français Deutsch Nederlands Espagñol Italiano

Entry Level Speed/Depth Display. English Français Deutsch Nederlands Espagñol Italiano Entry Level Speed/Depth Display Français Deutsch Nederlands Espagñol Italiano Entry Level Speed/Depth Display Important Suitability: the Entry Level Speed/Depth System is only recommended for use on cruising

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any Receiving Card MRV328 Document Version: Document Number: V1.0.0 NS110100409 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

Product model and standard

Product model and standard Preface Thank you for purchasing the Ikan Blitz 400 HD Wireless Video System. This system features uncompressed high definition video with zero delay. Before using the product, please read this user s

More information

INVISILED ACCESSORIES

INVISILED ACCESSORIES Indoor mounting accessories v" 5 feet LED-T-CH Aluminum Channel Includes a diffuser, two end caps, and five screws a" 2 pcs LED-T-CH-EC End caps for Aluminum Channel 1" 5 feet LED-T-CH1 Deep Aluminum Channel

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

HDCVI Camera User s Manual

HDCVI Camera User s Manual HDCVI Camera User s Manual Version 1.0.0 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Device Cable Structure... 4 4 Device Installation...

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

DCL9AW. User Manual. English

DCL9AW. User Manual. English DCL9AW User Manual English PRECAUTIONS Information for users applicable in European Union countries 1 Information for users applicable in United States of America 1 Installation 1 Power connection 1 Maintenance

More information

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter User s Guide Made in Taiwan Congratulations for owning a gofanco product. Our products aim to meet all your connectivity needs wherever you go. Have

More information

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

C-net MULTI Operating Instructions MULTI. User s Guide

C-net MULTI Operating Instructions MULTI. User s Guide MULTI User s Guide -1- Introduction. Thank you for buying this C-net product. We wish you to enjoy your boating and intend that all C-net instruments enhance your pleasure. The instruments are designed

More information

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly. Table of Contents Introduction...3 Safety Information...4-6 Before Beginning Installation...7 Installation Guide...8 Wiring Camera & Monitor...9-10 Replacement Installation Diagram...11 Clip-On Installation

More information

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KBF P 240 Humidity test chambers with ICH-compliant light source Model KBF P 240 Humidity test chambers with ICH-compliant light source The KBF P humidity test chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and

More information

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction: 6.4 Chassis Monitor Model Number: LCM0642xx This product is RoHS compliant SPEC No.: SAS-0908003 Version: 0.0 Issue Date: April 16, 2010 1. Introduction: 1.1 About the Product The LCM0642xx 6.4 Chassis

More information

Troubleshooting CS800/LC900 Bikes

Troubleshooting CS800/LC900 Bikes Troubleshooting CS800/LC900 Bikes CS800/900LC Bike Troubleshooting Entering the Maintenance Mode 15 Touch Screen: The Maintenance Mode is designed to help the tech determine certain faults in the upper

More information

Owners SW-LCD 2.0 Manual & Specifications

Owners SW-LCD 2.0 Manual & Specifications Owners SW-LCD 2.0 Manual & Specifications Contents 1. Preface. 19 2. Appearance and Size.20 2.1 Material and Color 20 2.2 Display Size and Installation Size 20 3. Function Summary and Button Definition

More information

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR 19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR V193/ V220 Series V202 Series USER MANUAL www.viewera.com Rev. 2.0 Table of Contents EMC Compliance......1 Important Precautions...2 1. Package contents....3

More information

MT03A Electronic converter for flow rate transmitters

MT03A Electronic converter for flow rate transmitters Instructions manual MT03A Electronic converter for flow rate transmitters The art of measuring R-MI-MT03A Rev.: 0 English version PREFACE Thank you for choosing a Tecfluid S.A product. This instruction

More information

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features High-performance Vision Sensor Advanced algorithm enables ultra high speed and maximum flexibility Features Inspection and positioning that was difficult with previous vision sensors is now surprisingly

More information

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan PRO-HDMI2HD HDMI to SDI/3G-HD-SD Converter User Manual Made in Taiwan rev.1008 103 Quality Circle, Suite 210 Huntsville, Alabama 35806 Tel: (256) 726-9222 Fax: (256) 726-9268 Email: service@pesa.com Safety

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

INSTALLATION GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S

INSTALLATION GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S INSTALLATION GUIDE DYNAMIC TRIM CONTROL SYSTEM SERIES S Drill bits TOOLS Power drill Ø Ø Ø Ø Ø 2.5 mm (3/32 ) 3 mm (1/8 ) 3.5 mm (9/64 ) 4 mm (5/32 ) 5 mm (3/16 ) Sealant Hole saw Screw bits Ø 76 mm (3

More information

Draft_08_April_2015. Antenna maximum rotation. Drawings Halo pulse compression radar installation manual. 6 ft 4 ft 3 ft

Draft_08_April_2015. Antenna maximum rotation. Drawings Halo pulse compression radar installation manual. 6 ft 4 ft 3 ft Antenna maximum rotation 6 ft 4 ft 3 ft 2045 mm (80.51") 1431 mm (56.77") 1141 mm (44.92") Drawings Halo pulse compression radar installation manual 35 9 Spare Parts Part Number Description 000-11463-001

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m)

Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m) Wall Plate HDMI over CAT5 Extender with Power Over Cable 1080p 165ft (50m) Product ID: ST121HDWP The ST121HDWP HDMI over CAT5 Extender Wall Plate Kit lets you extend your HDMI audio/video up to 165 feet

More information

Operating Instructions

Operating Instructions Operating Instructions LCDRV700 Digital LCD Color Monitor Please read this manual thoroughly before operating the unit, and keep it for future reference. V1.0 Contents 1. Precautions 2. Features 1 3 3.

More information

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit DH7-DK QUICKSTART GUIDE DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit What s Included 1 x DH7 Monitor 1 x AC Adapter 1 x Camera Shoe Mount 1 x Screen Cleaning Wipe 1 x Screen Protection Film 1

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

MODE MENU /F1 /F2 F3 F4 PLCMHD80

MODE MENU /F1 /F2 F3 F4 PLCMHD80 MODE MENU /F1 /F2 F3 F4 PLCMHD80 ! To insure best use of the unit, please read the user s manual carefully CAUTION 1. Do not use any damaged or leaking battery, if using a battery to power. 2. Do not expose

More information

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Advantech Proudly Presents Professional Monitor Series

Advantech Proudly Presents Professional Monitor Series Advantech Proudly Presents Professional Monitor Series Model PN-E421 P/N: DSD-420N-70FH-S1E The 42" Class (42-1/16" Diagonal) LCD monitor offers exceptionally high image quality and reliability for use

More information

1x12 VGA & Audio over CAT5 Splitter

1x12 VGA & Audio over CAT5 Splitter SP-9112 1x12 VGA & Audio over CAT5 Splitter User Manual rev: 160322 Made in Taiwan Safety and Notice The SP-9112 1x12 VGA & Audio over CAT5 Splitter has been tested for conformance to safety regulations

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02 Owner s Manual multiswitch 1.41 Firmware-Version 1.06 OS- Version 1.02 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of: Juli 19 th

More information

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual. Marshall Electronics Pro A/V Communications VMV-402-SH 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display User Manual Table of Contents 1. Introduction... 3 2. Features... 3 3. Package Contents...

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

QLOCKTWO CLASSIC. Instructions for use

QLOCKTWO CLASSIC. Instructions for use QLOCKTWO CLASSIC Instructions for use www.qlocktwo.com EN All in good time QLOCKTWO Instructions for use Read these instructions fully and carefully before using the QLOCKTWO CLASSIC for the first time.

More information

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA The JS007WQK is loaded with userfriendly features and is ideal for use in heavy duty vehicles.

More information

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual INTRODUCTION Congratulations on your purchase of the VGA CAT-5 1:8 Distribution S. Your complete satisfaction

More information

Owner s Manual LED COMMANDER 16/2

Owner s Manual LED COMMANDER 16/2 Owner s Manual LED COMMANDER 16/2 Content Introduction...2 Technical Specification...2 Maintenance and care...2 Notes on safety...3 Features...4 Overview...5 Installation...6 Operation...6 Channel Assignment...7

More information

Detect Color and Shape for various inspection

Detect Color and Shape for various inspection CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

PLL2710W LED LCD Monitor

PLL2710W LED LCD Monitor PLL2710W LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5 Rear View of the Product...6

More information

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES APPLICATION LPD04SA-15B-R (29.9 59.9 172mm) This product is digital display for system which is most suitable for display of various data of main

More information

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17 1/3 RACK-MOUNTED BLOCK CONVERTER Unit shown with Option 17 Unit shown without Option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model KBF 720 Constant climate chambers with large temperature / humidity range Model KBF 720 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure

More information

Operating Instructions

Operating Instructions Marshall Electronics Broadcast A/V Division Model No. V-LCD70W-SH 7 3G-SDI / HDMI Professional Camera-Top Monitor Operating Instructions Ver. 1.0 V-LCD70W-SH Operation Manual Table of Contents 1. Installation

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual 1178.6733.02 01 User Manual The User Manual describes the following R&S OSP-B200R/B200S2 models and accessories: R&S OSP-B200R/B200S2 (1528.3140.02)

More information

Operating Manual for Clock / Auxiliary Displays for VHX systems

Operating Manual for Clock / Auxiliary Displays for VHX systems Operating Manual for Clock / Auxiliary Displays for VHX systems The VHX auxiliary display module is designed to work with a Dakota Digital VHX system and will not function properly on its own. With this

More information

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8 4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8 2010 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview

More information

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE ? 8 LCD Screen? 10.4 LCD Screen LCD Zoom Microscope Instruction Manual Please read the Instruction Manual carefully before installation and keep it for future

More information

Model KT 170 Cooling incubators with thermoelectric cooling

Model KT 170 Cooling incubators with thermoelectric cooling Model KT 170 Cooling incubators with thermoelectric cooling BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C Energy efficient, environmentally

More information

Liner Quattro AC XB RGBW

Liner Quattro AC XB RGBW Date: Quantity: Company: Project: Liner Quattro AC XB RGBW The Liner Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

SPACESCAN SERIES SS 02

SPACESCAN SERIES SS 02 Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc

More information

PXL2760MW LED LCD Monitor

PXL2760MW LED LCD Monitor PXL2760MW LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5 Rear View of the Product...6

More information

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying

More information

Delvcam DELV-3GHD-17RM

Delvcam DELV-3GHD-17RM Delvcam DELV-3GHD-17RM 17.3" High Resolution 3G-SDI/HDMI Rackmount LCD Video Monitor IMPORTANT SAFETY INSTRUCTIONS Read manual before using this product. Keep manual for future reference. Do not place

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

PXL2470MW LED LCD Monitor

PXL2470MW LED LCD Monitor PXL2470MW LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Unpacking Instructions...2 Safety Precautions...2 Package Overview...3 First Setup...4 Front View of the Product...5

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information