Installation guide M F RESOLUTE

Size: px
Start display at page:

Download "Installation guide M F RESOLUTE"

Transcription

1 Installation guide M F RESOLUTE RSLM high accuracy RTLA-S linear absolute encoder linear encoder system

2 Contents Product compliance 1 Storage and handling 2 Installation drawing: RESOLUTE readhead 3 Installation drawing: RESOLUTE readhead side cable outlet 4 Installation drawing: RTLA-S 5 Scale application 6 End covers 6 Datum clamp 6 Readhead mounting/installation 7 Electrical connections 7 Scale technical specifications 8 BiSS-C serial comms 9 FANUC serial comms 10 Mitsubishi serial comms 11 Panasonic / OMRON serial comms 12 Yaskawa serial comms 13 Siemens DRIVE-CLiQ serial comms 14 Siemens DRIVE-CLiQ interface 15 RESOLUTE RTLA-S installation guide

3 Product compliance C Renishaw plc declares that RESOLUTE complies with the applicable standards and regulations. A copy of the EC Declaration of Conformity is available on request. FCC compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance. RoHS compliance Compliant with EC directive 2011/65/EU (RoHS) Disclaimer RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. The packaging of our products contains the following materials and can be recycled. Packaging Component Material ISO Recycling Guidance Outer box Cardboard Not applicable Recyclable Polypropylene PP Recyclable Inserts Low Density Polyethylene Foam LDPE Recyclable Cardboard Not applicable Recyclable Bags High Density Polyethylene Bag HDPE Recyclable Metalised Polyethylene PE Recyclable Patents Features of Renishaw s encoder systems and similar products are the subjects of the following patents and patent applications: CN US JP GB CN EP JP CN EP JP US KR CN EP KR US CN EP US KR Further information Further information relating to the RESOLUTE encoder range can be found in the RESOLUTE Data sheets. These can be downloaded from our website and are also available from your local representative. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor. RESOLUTE RTLA-S installation guide 1

4 Storage and handling Readhead and DRIVE-CLiQ interface Scale and readhead N-heptane Propan-2-ol CH 3 (CH 2 ) 5 CH 3 CH 3 CHOHCH 3 Storage Operating Humidity Minimum bend radius System Standard +80 C 20 C UHV +80 C 0 C Bakeout +120 C Standard Readhead +80 C 0 C UHV +75 C 0 C 95% relative humidity (non-condensing) to EN RTLA-S 150 mm NOTE: Ensure self-adhesive tape is on outside of bend. DRIVE-CLiQ interface +55 C 0 C RESOLUTE RTLA-S installation guide 2

5 Installation drawing: RESOLUTE readhead Dimensions and tolerances in mm (Yaw tol. ±0.5 ) 0.31 Set-up LED min 16.5 R>20 Dynamic bend radius R>10 Static bend radius Ø 4.7 ± typ* 2 mounting holes M3 through, counterbored each side, 3 deep 17.2 (Roll tol. ±0.5 ) 0.05 A 6 typ* * Extent of mounting faces Recommended thread engagement 5 min (8 mm including counterbore) Recommended tightening torque 0.5 to 0.7 Nm (Pitch tol. ±0.5 ) 0.31 UHV cable diameter 2.7. Dynamic bend radius not applicable for UHV cables ±1 Scale and optical centreline Optical centreline Detail A Orientation of scale determines count direction Scale reading surface Scale thickness 0.2 Adhesive thickness 0.2 Moving head increases count direction Moving head increases count direction NOTE: Reversing head orientation has no effect on count direction Readhead to scale clearance Rideheight 0.8 ±0.15 RESOLUTE RTLA-S installation guide 3

6 Installation drawing: RESOLUTE readhead side cable outlet Dimensions and tolerances in mm (Yaw tol. ±0.5 ) 0.31 Set-up LED min R>20 Dynamic bend radius R>10 Static bend radius Ø4.7 ± mounting holes M3 8.5 deep (counterbored 3 deep) 10 typ* typ* 17.2 (Roll tol. ±0.5 ) Rideheight 0.8 ± ±1 (Pitch tol. ±0.5 ) 0.31 Scale centreline Optical centreline *Extent of mounting faces. Thread depth from mounting face. Recommended thread engagement 5 mm (8 including counterbore). Recommended tightening torque 0.5 to 0.7 Nm. RESOLUTE RTLA-S installation guide 4

7 Installation drawing: RTLA-S (adhesive datum clamp) Dimensions and tolerances in mm START Overall length (L + 37) Scale length (L) FINISH Measuring length ML = (L 17) F 0.2/100 F = axis of motion A 5 B Datum clamp (A ) Optional end cover (Pair A ) Readhead optical detector position at extent of travel Ra F F = axis of motion C Optical centreline Detail A Detail B Detail C 12.5 End cover alignment indicator RESOLUTE RTLA-S installation guide 5

8 Scale application The scale applicator A is designed specifically for use with RESOLUTE readheads and RTLA-S scale. 1 Allow scale to acclimatize to installation environment prior to installation. 2 Mark out the START and FINISH points for the scale on the axis substrate ensure that there is room for the optional end covers if required (see RTLA-S installation drawing ). 3 Thoroughly clean and degrease the substrate using recommended solvents see 'Storage and handling'). Allow substrate to dry before applying scale. 4 Mount the appropriate scale applicator to the readhead mounting bracket using M3 screws. Place the shim supplied with the readhead between the applicator and substrate to set the nominal height. NOTE: Scale applicator can be mounted either way round to enable easiest orientation for scale installation. 5 Move axis to START of travel. 6 Begin to remove the backing paper from the scale and insert scale into the applicator up to the START point (as shown). Ensure backing tape is routed under the splitter screw. 7 Apply finger pressure to the scale at the START point, using a clean lint-free cloth, to ensure scale end adheres well to the substrate. 8 Slowly and smoothly move the applicator through the entire axis of travel, ensuring the backing paper is pulled manually from the scale and does not catch under the applicator. Direction of scale application RTLA-S START point End covers The end cover kit A is designed to be used with RTLA-S scale to provide protection for exposed scale ends. NOTE: End covers are optional and can be fitted before or after readhead installation. 1 Remove the backing tape from the adhesive tape on the back of the end cover. 2 Align markers on the edges of the end cover with the end of the scale and place end cover over the scale. NOTE: There will be a gap* between the end of the scale and the adhesive tape on the end cover. Datum clamp (A ) The datum clamp fixes the RTLA-S scale rigidly to the substrate at the location chosen. The metrology of the system may be compromised if the datum clamp is not used. It can be positioned anywhere along the axis depending upon the customers requirements. 1 Place the datum clamp with cut-out against the scale at the chosen location. *gap Splitter screw Backing tape 9 Remove applicator and, if necessary, adhere the remaining scale manually. Apply firm finger pressure via a clean lint-free cloth along the length of the scale after application to ensure complete adhesion. 10 Clean scale using Renishaw scale cleaning wipes (A ) or a clean, dry, lint-free cloth. 11 Fit end covers. START 12 Allow 24 hours for complete adhesion of scale before fitting datum clamps. 2 Place a small amount of adhesive (Loctite 435 ) in the cut-out on the datum clamp, ensuring none of the adhesive wicks onto the scale surface. Dispensing tips P-TL are available. Ensure the adhesive wicks along the entire length of cut-out. RESOLUTE RTLA-S installation guide 6

9 Readhead mounting/installation Electrical connections Mounting brackets The bracket must have a flat mounting surface, enable conformance to the installation tolerances, allow adjustment of the rideheight of the readhead, and be sufficiently stiff to prevent deflection of the readhead during operation. Readhead set-up Ensure that the scale, readhead optical window and mounting face are clean and free from obstructions. To set nominal rideheight for RTLA-S installations, use the Blue 0.8 mm readhead spacer to set rideheight. Adjust the readhead to maximize the signal strength along the full axis of travel to achieve a Green or Blue LED. RESOLUTE grounding and shielding Readhead Inner shield Outer shield Connector Extension cable* Customer electronics 5 V 0 V Serial communication signals Readhead set-up LED and DRIVE-CLiQ interface set-up STATUS LED status Blue Green Orange Red Yaw 0 ±0.5 NOTE: Flashing of set-up LED indicates scale reading error. Flashing state is latched for some serial protocols. (Remove power to reset). Roll 0 ±0.5 Pitch 0 ±0.5 IMPORTANT: The outer shield should be connected to the machine earth (Field ground). The inner shield should be connected to 0 V at customer electronics only. Care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues. IMPORTANT: If the flying lead variant is used or the connector is modified or replaced, the customer must ensure both 0 V cores (White and Green) are connected to 0 V. *For Siemens DRIVE-CLiQ please refer to Siemens DRIVE-CLiQ specifications for maximum cable length. For UHV there is no inner shield to be connected. RESOLUTE grounding and shielding - Yaskawa protocol only Readhead Connector Extension cable Customer electronics 5 V Serial communication signals Shield 0 V Rideheight 0.8 ±0.15 mm IMPORTANT: The shield should be connected to the machine earth (Field ground). IMPORTANT: If the connector is modified or replaced, the customer must ensure both 0 V cores (White and Green) are connected to 0 V. RESOLUTE RTLA-S installation guide 7

10 Scale technical specifications RTLA-S Form (H W) Datum fixing Material 0.4 mm 8 mm (including adhesive) Datum clamp (A ) secured with Loctite 435 (P-AD ) Hardened and tempered martensitic stainless steel fitted with a self-adhesive backing tape Accuracy (at 20 C) ±5 µm/m, calibration traceable to International Standards Coefficient of thermal expansion (at 20 C) 10.1 ±0.2 µm/m/ C Mass 12.2 g/m Installation temperature 15 C to 35 C Maximum length* The maximum scale length is determined by the readhead resolution and the number of position bits in the serial word. For RESOLUTE readheads with fine resolution and short word length, the maximum scale length will be limited accordingly. Conversely, coaser resolutions or longer word lengths enable the use of longer scale lengths. Serial protocol Protocol word length Maximum scale length (m) Resolution 1 nm 5 nm 50 nm 100 nm BiSS 26 Bit N/A 32 Bit N/A 36 Bit N/A Yaskawa 36 Bit 1.8 N/A 21 N/A FANUC 37 Bit 21 N/A 21 N/A Mitsubishi 40 Bit 2.1 N/A 21 N/A Panasonic 48 Bit 21 N/A Siemens 28 Bit N/A N/A N/A DRIVE-CLiQ 34 Bit N/A N/A N/A *For lengths >2 m RTLC20 with FASTRACK is recommended RESOLUTE RTLA-S installation guide 8

11 BiSS-C serial comms General specifications Power supply (standard and UHV) 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (standard) IP64 (UHV) IP30 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (standard) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (UHV) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass (standard) Readhead 18 g Cable 32 g/m (UHV) Readhead 19 g Cable 19 g/m Readhead cable (standard) 7 core, tinned and annealed copper, 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius (UHV) Maximum readhead cable length UL recognised component Silver-coated copper braided single screen FEP core insulation over tin-plated copper wire 10 m For maximum extension cable length, contact your local Renishaw representative Output signals Function Signal Wire colour For details, refer to BiSS Data sheet L *No inner shield for UHV variant. NOTE: For UHV readhead only flying lead option available 9 way D-type Pin 9 way D-type Power 5 V Brown 4, 5 Serial communications 0 V White Green MA+ Violet 2 MA Yellow 3 SLO+ Grey 6 SLO Pink 7 Shield Inner* Inner shield 1 8, 9 Outer Outer shield Case The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. RESOLUTE RTLA-S installation guide 9

12 FANUC serial comms General specifications 9 way D-type Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes 31 Maximum acceleration of scale with respect to readhead 690 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. 20 way plug Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper, 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius Maximum readhead cable length UL recognised component 10 m For maximum extension cable length, contact your local Renishaw representative Outer shield (connect to machine ground) The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. Output signals Lemo 46.6 Function Signal Wire colour Pin 9 way D-type Lemo 20 way max Power 5 V Brown 4, , Serial White 0 V Green 8, 9 12, 8 12, 14 REQ Violet M communications *REQ Yellow SD Grey *SD Pink Shield Inner Inner shield Outer Outer shield Case Case External NOTE: For Lemo option, mating extension cables and sealing caps are available from your local Renishaw representative. RESOLUTE RTLA-S installation guide 10

13 Mitsubishi serial comms General specifications Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated Sealing Ripple RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN mvpp frequency up to 500 khz IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper, 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius Output signals Function Signal Wire colour Pin 15 way D-type Power 5 V Brown 7, 8 White 0 V Green 2, 9 Serial MR Violet 10 communications MRR Yellow 1 MD Grey 11 MDR Pink 3 Shield Inner Inner shield 15 Outer Outer shield Case For 2 wire do not connect MD and MDR. 15 way D-type UL recognised component Maximum readhead cable length 1 m* For maximum extension cable length, contact your local Renishaw representative The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential *Lengths above 1 m available on special order. RESOLUTE RTLA-S installation guide 11

14 Panasonic / OMRON serial comms General specifications Power supply (standard and UHV) 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (standard) IP64 (UHV) IP30 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (standard) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (UHV) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass (standard) Readhead 18 g Cable 32 g/m (UHV) Readhead 19 g Cable 19 g/m Readhead cable (standard) 7 core, tinned and annealed copper, 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius Output signals Function Signal Wire colour *No inner shield for UHV variant. NOTE: For UHV readhead only flying lead option available. Pin 9 way D-type M12 ( A code) Power 5 V Brown 4, 5 2 Serial communications 0 V White Green 8, 9 5, 8 REQ+, SD+ Violet 2 3 REQ, SD Yellow 3 4 Shield Inner* Inner shield 1 1 Reserved 9 way D-type Outer Outer shield Case Case Do not connect 52 Grey 6 7 Pink UL recognised component (UHV) Silver-coated copper braided single screen FEP core insulation over tin-plated copper wire Maximum readhead cable length 10 m For maximum extension cable length, contact your local Renishaw representative M AF The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. M12 10 RESOLUTE RTLA-S installation guide 12

15 Yaskawa serial comms General specifications Power supply 5 V ±10% 1.25 W maximum (250 5V) NOTE: Current consumption figures refer to terminated Sealing Ripple RESOLUTE systems. Renishaw encoder systems must be powered from a 5 V dc supply complying with the requirements for SELV of standard IEC BS EN mvpp frequency up to 500 khz IP64 Acceleration Operating 500 m/s 2, 3 axes Shock Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Readhead cable (standard) 7 core, tinned and annealed copper, 28 AWG Single shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius Output signals Pin Function Signal Wire colour 9 way D-type M12 ( A code) Power 5 V Brown 4, 5 2 White 0 V Green 8, 9 5, 8 Serial S Violet 2 3 communications S Yellow 3 4 Shield Shield Shield Case Case Reserved Grey 6 7 Do not connect Pink way D-type UL recognised component Maximum readhead cable length 10 m For maximum extension cable length, contact your local Renishaw representative The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. M AF M12 10 RESOLUTE RTLA-S installation guide 13

16 Siemens DRIVE-CLiQ serial comms General specifications Power supply (DRIVE-CLiQ system) 24 V 1.8 W maximum (75 24 V), 24 V as per DRIVE-CLiQ specification 24 V power is provided by the DRIVE-CLiQ network NOTE: The Renishaw DRIVE-CLiQ interface must be powered from a 24 V dc supply complying with the requirements for SELV of standard IEC BS EN Ripple 200 mvpp frequency up to 500 khz Sealing (readhead) IP64 (interface) IP67 Acceleration (readhead) Operating 500 m/s 2, 3 axes Shock (readhead and interface) Non-operating 1000 m/s 2, 6 ms, ½ sine, 3 axes Maximum acceleration of scale with respect to readhead 2000 m/s 2 NOTE: This is the worst case figure that is correct for the slowest communications clock rates. For faster clock rates, the maximum acceleration of scale with respect to the readhead can be higher. For more details, please contact your local representative. Vibration (readhead) Operating 300 m/s 2, 55 Hz to 2000 Hz, 3 axes (interface) Operating 100 m/s 2, 55 Hz to 2000 Hz, 3 axes Mass Readhead 18 g Cable 32 g/m Interface 218 g Readhead cable 7 core, tinned and annealed copper, 28 AWG Double shielded, outside diameter 4.7 ±0.2 mm Flex life > cycles at 20 mm bend radius Maximum readhead cable length Connector tightening torque UL recognised component Readhead to DRIVE-CLiQ interface 10 m (Refer to Siemens DRIVE-CLiQ specifications for maximum cable length from interface to controller) M12 4 Nm Output signals Signals between readhead and interface Function Signal Wire colour Pin M12 ( A code) Power 5 V Brown 2 White 0 V Green 5, 8 Serial A+ Violet 3 communications A Yellow 4 Shield Inner Inner shield 1 Outer Outer shield Case Reserved Grey 7 Do not connect Pink 6 Interface output Pin Function Signal M12 ( A code) Power 24 V 1 0 V 5 DRIVE-CLiQ RX+ 3 communications RX 4 TX+ 7 TX 6 Shield Case The RESOLUTE encoder system has been designed to the relevant EMC standards, but must be correctly integrated to achieve EMC compliance. In particular, attention to shielding arrangements is essential. M12 Electrical connections AF RESOLUTE grounding and shielding Readhead Inner shield Outer shield Siemens DRIVE-CLiQ connection IMPORTANT: If reterminating readhead cable care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between 0 V and earth, which could cause electrical noise issues. M12 10 DRIVE-CLiQ interface DRIVE-CLiQ cable RESOLUTE RTLA-S installation guide 14

17 Siemens DRIVE-CLiQ interface Dimensions and tolerances in mm DRIVE-CLiQ interface installation drawing off mounting holes Ø5.5 through Single readhead (A ) LED indicators M12 8-way female for readhead connection M12 8-way male for DRIVE-CLiQ connection (including power supply) RDY LED functions Colour Status Description Off Power supply is missing or outside of permissible tolerance range Green Continuous light The component is ready for operation and cyclic DRIVE-CLiQ communication is taking place Orange Continuous light DRIVE-CLiQ communication is being established Red Continuous light At least one fault is present in this component. NOTE: The LED is activated regardless of whether the corresponding messages have been reconfigured Green/Orange or Red/Orange Flashing light Component recognition via LED is activated (p0144) NOTE: Both options depend on the LED status when component recognition is activated via p0144=1 STATUS LED function STATUS displays the readhead set-up status as shown on the readhead set-up LED Blue Green Orange Red RESOLUTE RTLA-S installation guide 15

18 Renishaw plc New Mills, Wotton-under-Edge Gloucestershire, GL12 8JR United Kingdom T +44 (0) F +44 (0) E uk@renishaw.com RSLM high accuracy linear encoder For worldwide contact details, please visit our main website at RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countries. apply innovation and names and designations of other Renishaw products and technologies are trade marks of Renishaw plc or its subsidiaries. Loctite is a registered trade mark of the Henkel Corporation Renishaw plc All rights reserved Issued 1218 *M *

Installation guide M C

Installation guide M C Installation guide M-9553-9128-05-C RESOLUTE RSLM high accuracy RSLA/RELA linear encoder high accuracy absolute linear encoder Contents Product compliance 1 Storage and handling 2 Installation drawing:

More information

Installation guide M C. RESOLUTE RESA and REXA absolute angle encoders

Installation guide M C. RESOLUTE RESA and REXA absolute angle encoders Installation guide M-9553-9735-02-C RESOLUTE RESA and REXA absolute angle encoders Contents Product compliance 1 Storage and handling 2 Readhead installation drawing 3 Readhead side cable outlet installation

More information

RESOLUTE absolute optical encoder with Panasonic serial communications

RESOLUTE absolute optical encoder with Panasonic serial communications L-9517-9460-07-A RESOLUTE absolute optical encoder with Panasonic serial communications True absolute non-contact optical encoder system: no batteries required Wide set-up tolerances for quick and easy

More information

Installation guide M A

Installation guide M A Installation guide M-9562-9063-02-A RGH25F RSLM high RGS20 accuracy linear encoder system Contents Product compliance 1 Storage and handling 2 RGH25F readhead installation drawing 3 REF interface installation

More information

QUANTiC RKLC40-S incremental linear encoder system

QUANTiC RKLC40-S incremental linear encoder system Installation guide M-9417-9238-01-A RSLM high accuracy linear encoder QUANTiC RKLC40-S incremental linear encoder system Contents Product compliance 1 Storage and handling 2 QUANTiC readhead installation

More information

TONiC T103x RTLC-S linear encoder system

TONiC T103x RTLC-S linear encoder system Installation guide M959901303B RSLM high accuracy linear encoder TONiC T3x RTLCS linear encoder system Contents Product compliance Storage and handling TONiC readhead installation drawing RTLCS installation

More information

DOP (dual output) encoder system

DOP (dual output) encoder system Installation guide M-9653-9278-01-D (dual output) encoder system RSLM high accuracy linear encoder Renishaw plc declares that complies with the applicable standards and regulations. A copy of the EC Declaration

More information

QUANTiC RESM40 angle encoder system

QUANTiC RESM40 angle encoder system Installation guide M-9417-9201-01-A RSLM high accuracy linear encoder QUANTiC RESM40 angle encoder system Contents Product compliance 1 Storage and handling 2 RESM40: Installation drawing ( A section)

More information

Installation guide M A

Installation guide M A Installation guide M-97-9000-03-A TONiCRSLM T20x1 high accuracy RESD linear angle encoder encoder system Contents Product compliance 1 Storage and handling 2 Installation drawing ( A section RESD) 3 TONiC

More information

Installation guide M A. VIONiC RESM20 / REST20 angle encoder system

Installation guide M A. VIONiC RESM20 / REST20 angle encoder system Installation guide M-6195-9218-02-A VIONiC RESM20 / REST20 angle encoder system Contents Product compliance 1 Storage and handling 2 RESM20/REST20 installation drawing ( A section) 3 RESM20/REST20 installation

More information

TONiC T103x RTLC/FASTRACK linear encoder system

TONiC T103x RTLC/FASTRACK linear encoder system Installation guide M9589900203C RSLM high accuracy linear encoder TONiC T3x RTLC/FASTRACK linear encoder system Contents Product compliance 1 Storage and handling 2 TONiC readhead installation drawing

More information

TONiC T100x RGSZ linear encoder system

TONiC T100x RGSZ linear encoder system Installation guide M9653915405B RSLM high accuracy linear encoder TONiC T0x RGSZ linear encoder system Contents Product compliance 1 Storage and handling 2 TONiC readhead installation drawing 3 RGSZ20S

More information

Installation guide M D

Installation guide M D Installation guide M95391103D TONiCRSLM T20x1 high accuracy RESM linear angle encoder encoder system Contents Product compliance 1 Storage and handling 2 RESM installation drawing ( A section) 3 RESM installation

More information

LM10 linear magnetic encoder system

LM10 linear magnetic encoder system RLS merilna tehnika d.o.o. Cesta II. grupe odredov 5 SI-161 Ljubljana - Dobrunje Slovenia T +86 1 57100 F +86 1 5719 E mail@rls.si www.rls.si Installation guide Issue 4, 14 th January 009 LM10 linear magnetic

More information

ATOM miniature encoder system

ATOM miniature encoder system L70D ATOM miniature encoder system ATOM is the world s first miniature encoder with filtering optics, providing improvements in dirt immunity, signal stability and reliability for linear and rotary applications.

More information

ATOM miniature encoder system

ATOM miniature encoder system L70A ATOM miniature encoder system ATOM is the world s first miniature encoder with filtering optics, providing improvements in dirt immunity, signal stability and reliability for linear and rotary applications.

More information

User guide M A. Advanced Diagnostic Tool ADTi-100 and ADT View software

User guide M A. Advanced Diagnostic Tool ADTi-100 and ADT View software User guide M-6195-9413-02-A Advanced Diagnostic Tool ADTi-100 and ADT View software Contents 1 General information 1 1.1 Overview 1 1.2 Product compliance 2 1.3 Minimum requirements 2 1.4 General specifications

More information

Installation guide H A. OMI-2H optical machine interface

Installation guide H A. OMI-2H optical machine interface Installation guide H-5157-8504-01-A OMI-2H optical machine interface 2016 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH USER GUIDE AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH Electromagnetic Compatibility (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in

More information

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach NEW DRS: Incremental encoders, number of lines and zero pulse width freely programmable DRS: s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation... Li nearenc oder s wi t httlout put Us ermanual Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

HD-One DX/DX500 HDMI Extender

HD-One DX/DX500 HDMI Extender HD-One DX/DX500 HDMI Extender User Manual Version 2.0 tvone 2791 Circleport Drive, Erlanger, KY 41018, USA. Americas: 859-282-7303 EMEA: +44 (0) 1843 873322 Email: tech.usa@tvone.com www.tvone.com CSG-DX-500

More information

Product Information. LIC 4113 LIC 4193 Absolute Exposed Linear Encoders

Product Information. LIC 4113 LIC 4193 Absolute Exposed Linear Encoders Product Information LIC 4113 LIC 4193 Absolute Exposed Linear Encoders November 2016 LIC 4113, LIC 4193 Absolute linear encoder for measuring lengths up to 3 m Measuring steps to 0.001 µm Measuring standard

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

ASH - EOC-01. Ethernet Over Coax Adapter User Guide ASH - EOC-01 Ethernet Over Coax Adapter User Guide ASH - EOC-01 User s Guide 1 Table of Contents Warning and Safety Information 3 Product Overview 8 Package Contents and Accessories 8 Introduction 9 Indicators

More information

E3/DS3 Fibre Extender

E3/DS3 Fibre Extender User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1

More information

ABS AT1100 Series. Assembly Type ABS AT Series Absolute Scale Unit (Standard Type) ABS AT Effective length Interface specifications

ABS AT1100 Series. Assembly Type ABS AT Series Absolute Scale Unit (Standard Type) ABS AT Effective length Interface specifications Assembly Type ABS AT Series (Standard Type) (esolution 0.05μm Specification) Features This series has adopted a new structure not easily subject to infiltration of coolant and a dust-proof rubber highly

More information

Stretch HDMI TM. User s Manual (M1-2000)

Stretch HDMI TM. User s Manual (M1-2000) Stretch HDMI TM User s Manual (M1-2000) Manual Contents Manual Contents 1-0 Welcome!, Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting, Maintenance, Technical

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch HDMI Extender over Single CAT 6 Cable with IR Control Model 103002 Extend HDMI audio and video connections up to 300 feet Utilize existing Cat 6 wiring for an easy installation Add up to 8 additional receivers

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

MAGNETIC TAPE. Series MB. incremental scale. Key-Features: MAGNETIC TAPE incremental scale Series MB Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...3 Installation Instruction...3 Digital Displays...4 Order Code...5 - Available

More information

Cables for robot applications

Cables for robot applications Cables for robot applications 67 Primary cables Robot primary cable Cable design Internal conductor Special conductor Strand class VI (super-fine wire) Highly flexible Core insulation TPM or PUR Core identification

More information

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE The is shown above. MANUAL PART NUMBER: 400-0114-004 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 HANDLING...2 CLEANING...2

More information

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it

More information

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide February 2007 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

ABS ST700 Compact Type Series

ABS ST700 Compact Type Series Separate Type ABS ST Series (High environmental resistance type) ABS ST700 Compact Type Series Features Scale base type Absolute measurement with separate type scales Non-contact detection is optimal for

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

HARTING Ethernet cabling cables and connectors, 4 wire

HARTING Ethernet cabling cables and connectors, 4 wire Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

WLS27 Multicolor LED Strip Light with EZ-STATUS

WLS27 Multicolor LED Strip Light with EZ-STATUS WLS7 Multicolor LED Strip Light with EZ-STATUS Instruction Manual Banner's WLS7 Multicolor LED Strip Light has a sturdy aluminum housing and is encased in a shatterproof, UV-stabilized, copolyester shell,

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information M8 and M Sensor Connectors XS_-EU For a wide range of applications the XS_-EU family of M8 and M sensor connectors provides the high performance and features making the family the ideal choice for standard

More information

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2 last updated: 2007-03-08 OPERATING MANUAL DMX Demultiplexer 3012B Mk2 (C) SOUNDLIGHT 1995-2007 * ALL RIGHTS RESERVED * NO PART OF THIS MANUAL MAY BE REPRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors All non-rohs products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales

More information

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE MANUAL PART NUMBER: 400-0133-001 PRODUCT REVISION: 0 CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION...

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

Interface Connectors for Miniature, Portable Terminal Devices

Interface Connectors for Miniature, Portable Terminal Devices NEW Interface Connectors for Miniature, Portable Terminal Devices ST Series Strong locking mechanism Right Mating direction Left Top 9N max. Overview Developed as external input/output connectors for the

More information

Up to 85% higher Service Life due to efficient sealing method.

Up to 85% higher Service Life due to efficient sealing method. Robot Accessories Feeding through Up to 85% higher Service Life due to efficient sealing method. 346 Robot Accessories Feeding through Feeding through DDF 2 Rotary Feed-through Series Size Page DDF 2 348

More information

Register your product and get support at www.philips.com/welcome SWW1890 User manual Contents 1 Important 4 Safety 4 English 2 Your Philips Wireless HD Net Connect 5 What is in the box 5 3 Overview 6

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

CMM cable guide. CMM cable guide. Documentation part number: H A. Issued

CMM cable guide.   CMM cable guide. Documentation part number: H A. Issued Documentation part number: H-1000-4053-18-A Issued 02 2019 1 General information 2004 2019 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

PLL1920M LED LCD Monitor

PLL1920M LED LCD Monitor PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6

More information

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE MANUAL PART NUMBER: 400-0133-002 CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL... 2 INSTALLATION... 2 CLEANING... 2 FCC / CE NOTICE...

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-LIGHT K30L Series With Independent Push Button Contact EZ-LIGHT K0L Series With Independent Push Button Contact Datasheet Compact with One, Two, or Three s and a Momentary Push Button Output Rugged, cost-effective and easy-to-install multicolor indicator light

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

ENC - LKE51 - L I B

ENC - LKE51 - L I B ENC-LKE51 Linear Magnetic Encoder FEATURES DESCRIPTION LKE51 ORDERING INFORMATION Resolutions: 5, 10, 25, and 50μm Linear Travel Speed: Up to 16m/s Standard Sensor for Linear and Rotary Axis Gap Clearance

More information

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red Datasheet Large Multicolor that Alternates Between Active Inputs Bright, uniform indicator light Alternates between colors when multiple inputs are active Models are available with up to five colors in

More information

MKH 8060 Directional studio microphone

MKH 8060 Directional studio microphone MKH 8060 Directional studio microphone Instruction manual Contents Contents Important safety information... 2 The MKH 8060... 3 Delivery includes... 4 Product overview... 5 Putting the MKH 8060 into operation...

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

EZ-STATUS WLS28-2 Multicolor LED Strip Light

EZ-STATUS WLS28-2 Multicolor LED Strip Light EZ-STATUS WLS8- Multicolor LED Strip Light Datasheet Banner's WLS8- Multicolor LED Strip Lights have sturdy aluminum housings, shatterproof windows, and environmental ratings that make it ideal for harsh

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723 User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723 Preface Read this user manual carefully before using this product. Pictures shown in this manual is

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.mm Mated Height U.FL Series Up to 6GHz Transmission Speed Mated Height Comparison (With E.FL series) 1.9(2.0Max) U.FL-LP(V)-00 2.(2.5Max)

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504-b

Quick Start Guide. Wireless TV Connection with Dongle.   GWHDKITD PART NO. Q1504-b Quick Start Guide Wireless TV Connection with Dongle GWHDKITD PART NO. Q1504-b www.iogear.com Package Contents 1 x GWHDKITD Transmitter 1 x GWHDKITD Receiver 1 x 3 feet HDMI Cable 1 x HDMI Extender Cable

More information

BUS UNITRONIC BUS CAN

BUS UNITRONIC BUS CAN BUS UNITRONIC BUS CAN For CAN bus systems; stationary applications; 120 Ω LAPP KABEL UNITRONIC BUS CAN UNITRONIC BUS CAN is designed to the CAN open and ISO11898 standard. It is well suited for high-speed

More information

CLV-401A CAMERA LINK VIDEO SPLITTER. User s Manual. Document # , Rev 1.1, 4/2/2018

CLV-401A CAMERA LINK VIDEO SPLITTER. User s Manual. Document # , Rev 1.1, 4/2/2018 CLV-401A CAMERA LINK VIDEO SPLITTER User s Manual Document # 201058, Rev 1.1, 4/2/2018 Vivid Engineering 415 Boston Turnpike, Suite 305 Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930 www.vividengineering.com

More information

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the

More information

NUMERIK JENA. LIA Series. Exposed Linear Encoder. with Signal Control. Mounting Instructions

NUMERIK JENA. LIA Series. Exposed Linear Encoder. with Signal Control. Mounting Instructions NUMERIK JENA LIA Series Exposed Linear Encoder with Signal Control Mounting Instructions 2 LIA Series Note During power-up procedure of the encoder system the level of power voltage and signal lines must

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4... LVDT Inductive Position Transducer Series SM ø12 mm ranges 2...200 mm linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6 out: AC, 0...10 V, 0...5 V, 4...20 ma with external or integrated cable electronics repeatability

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version Spectra Flood Q40 Exterior Fixture User Manual Order code: LEDJ284-40 Version LEDJ284N - 15 Version Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

PQ Labs Multi-Touch Screen G 2 Overlay

PQ Labs Multi-Touch Screen G 2 Overlay PQ Labs Multi-Touch Screen G 2 Overlay User Manual 2.0 52 inch PQ Labs Multi-Touch Overlay For 52 inch LCD/Plasma display Copyright 2008 PQ Labs Inc. All Rights Reserved. Disclaimer The information in

More information

Installation and user s guide H A. OMI - SSR optical machine interface

Installation and user s guide H A. OMI - SSR optical machine interface Installation and user s guide H-2000-5165-01-A OMI - SSR optical machine interface 2002 Renishaw. All rights reserved. Renishaw is a registered trademark of Renishaw plc. This document may not be copied

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

1-In / 2-Out. HDMI Splitter User s Guide

1-In / 2-Out. HDMI Splitter User s Guide 1-In / 2-Out HDMI Splitter 1500659 User s Guide We hope you enjoy your 1-In / 2-Out HDMI Splitter from RadioShack. This HDMI splitter allows the 4K2K digital signal from a HDMI device to be displayed on

More information

User s Manual. Document # , Rev 1.2, 6/12/2006

User s Manual. Document # , Rev 1.2, 6/12/2006 CAMERA LINK TM VIDEO SPLITTER User s Manual Document # 200205, Rev 1.2, 6/12/2006 Vivid Engineering 418 Boston Turnpike #104 Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930 www.vividengineering.com

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide Cable-Nook Jr. Welcome! We greatly appreciate your purchase of the Cable-Nook Jr. Interconnect Box. We are sure you will find it reliable and simple to use. Superior performance for the right price, backed

More information