Fan Filters & Thermal Management. Enclosure Solutions

Size: px
Start display at page:

Download "Fan Filters & Thermal Management. Enclosure Solutions"

Transcription

1 Fan Filters & Thermal Management Enclosure Solutions

2 Axair Fans UK Limited Contents Axair Fans offer the widest range of industrial fans available from a single source, operating as the exclusive UK distributor for seven international fan manufacturers. It is our policy to supply fans, ventilation equipment and accessories to commercial and industrial clients. By continually monitoring, developing and improving our own procedures, resources and staff training, we will provide consistently high quality products, service and technical support to our clients. Many products ranges within the Axair portfolio are available from stock within our 12000m3 warehouse, or on short lead times. Axair Fans UK Limited Enclosure Solutions Axair Fans provides full climate control solutions for effective enclosure cooling inside the enclosure or cabinet. Effective thermal management is essential for ensuring the reliability of electronic components within an enclosure. Our enclosure ventilation accessories will meet your needs for safe and reliable temperature control and prevent the premature failure of equipment within an electrical cabinet. Contact us for more information on , sales@axair-fans.co.uk or visit Our extensive range of climate control solutions for cabinets and enclosures effectively controls air movement and heat dissipation within electrical panels. PRESSURE COMPENSATION DEVICE PAGE 4 PAGE 5 PAGE 6 PG29 Fixing System Ø37mm IP55 PLASTIC ROOF EXHAUST UNIT FILTER FANS IP24/44/54/55. Also in metal version filter FANS PAGE 7 roof exhausts PAGE 8 accessories PAGE 9 5 sizes with/without fan. Optionally IP55 and EMC version LED LAMP 115/230Va.c. or multi-voltage 12/24/48 Vd.c. ON/OFF switch or infrared sensor, NO-NC THERMOSTAT Setting range: -10 to +80 C C or F version HYGROSTAT thermostats PAGE 11 thermal control PAGE 12 Setting range: 10-90%RH heaters PAGE 16 TWIN THERMOSTAT Setting range: -10 to +80 C C or F version COMPACT FANS led lighting frame fans special frame fans a.c./d.c. axial or centrifugal fans, also in IP55, all metal and HTR version. Several accessories available ANTI-CONDENSATION HEATERS Version with cable, terminal block or ventilated. Available in plastic (touch proof) or metal version W Denotes a non stocked line - Contact us for lead times 2 3

3 4 5 Filter Fan Units FPF Series FPF series are available in a choice of industry standard sizes both with and without fans. They provide protection to IP54 using robust G3 filter media; all fans incorporate ball bearings for optimum performance and working life. Roof Exhaust Fans T & TP Series Roof Exhaust Units - T Series A range of powerful, all metal centrifugal fan roof exhaust units for effective heat dissipation within enclosures. Cut-out Frequency Air Flow Temp. mm mm (V) (Hz) (W) (m³/h)** (ºC) FPF08KUG x105 92x ~ +60 FPF08KU115BR x105 92x Va.c. 50/60 9/7 23/30-10 ~ +50 FPF08KU230BR x105 92x Va.c. 50/60 10/8 23/30-10 ~ +50 FPF08KUD24BR x105 92x92 24 Vd.c ~ +50 FPF12KUG x x ~ +60 Frequency ed Air Flow (V) (Hz) (W) (m³/h)** T19U115B 115 Va.c. 50/60 58/71 550/590 T19U230B 230 Va.c. 50/60 62/78 550/590 T22U115B 115 Va.c. 50/60 130/ /850 T22U230B 230 Va.c. 50/60 125/ /850 ( ) data with uncertainty of ±15% FPF12KU24BER x x Va.c. 50/60 15/16 57/61-10 ~ +50 FPF12KU115BER x x Va.c. 50/60 20/18 57/61-10 ~ +50 FPF12KU230BER x x Va.c. 50/60 20/19 57/61-10 ~ +50 FPF12KUD24BR x x Vd.c ~ +50 FPF12KUD48BR x x Vd.c ~ +55 FPF13KUG x x ~ +60 FPF13KPU115BER x x Va.c. 50/60 20/18 110/ ~ +50 FPF13KPU230BER x x Va.c. 50/60 20/19 110/ ~ +50 FPF13KPUD24BR x x Vd.c ~ +50 FPF13KU115BER x x Va.c. 50/60 17/15 120/ ~ +50 FPF13KU230BER x x Va.c. 50/60 17/15 120/ ~ +50 FPF15KUG x x ~ +60 FPF15KPU115BER x x Va.c. 50/60 20/18 115/ ~ +50 FPF15KPU230BER x x Va.c. 50/60 20/19 115/ ~ +50 FPF15KPUD12BR x x Vd.c ~ +50 FPF15KPUD24BR x x Vd.c ~ +50 FPF15KPUD48BR x x Vd.c ~ +55 FPF15KMU115BER x x Va.c. 50/60 17/15 130/ ~ +50 FPF15KMU230BER x x Va.c. 50/60 17/15 130/ ~ +50 FPF15KU115BER x x Va.c. 50/60 30/30 240/ ~ +50 FPF15KU230BER x x Va.c. 50/60 29/29 240/ ~ +50 FPF15KUD24BR x x Vd.c ~ +50 FPF15KUD48BR x x Vd.c ~ +55 FPF15KGU115BER x x Va.c. 50/60 50/64 360/ ~ +55 FPF15KGU230BER x x Va.c. 50/60 67/87 360/ ~ +50 FPF15KGU400TBER x x ~ 50/60 71/93 360/ ~ +55 FPF15KUD24BER x x Vd.c ~ +55 FPF15KUD48BER x x Vd.c ~ +55 FPF20KUG x x ~ +60 Roof Exhaust Units - TP Series A range of plastic centrifugal fan roof exhaust units design to extract warm air out from the top of an enclosure. Frequency Air Flow Protection Degree (V) (Hz) (W) (m³/h)** IP TP19U IP24 TP19U IP54 TP19U IP55 TP19U115B 115 V a.c. 50/60 62/75 500/575 IP24 TP19U115B1 115 V a.c IP24 TP19U115B V a.c IP44 TP19U115B V a.c. 50/60 66/74 420/490 IP54 TP19U115B V a.c IP54 TP19U115B V a.c. 50/60 66/74 420/490 IP55 TP19U115B V a.c IP55 TP19U230B 230 V a.c. 50/60 67/83 500/575 IP24 TP19U230B1 230 V a.c. 50/60 70/81 500/575 IP24 TP19U230B V a.c. 50/60 69/81 485/560 IP44 TP19U230B V a.c. 50/60 70/81 485/560 IP44 TP19U230B V a.c. 50/60 70/83 420/490 IP54 TP19U230B V a.c. 50/60 70/81 420/490 IP54 TP19U230B V a.c. 50/60 70/83 420/490 IP55 TP19U230B V a.c. 50/60 70/81 420/490 IP55 ( ) data with uncertainty of ±15% Multi Directional Fan Perfect for spot cooling, the multi directional fan can be installed at the required location within the cabinet and manoeuvred to cool specific components and areas. FPF20KU115BER x x Va.c. 50/60 50/64 520/ ~ +55 FPF20KU230BER x x Va.c. 50/60 67/87 520/ ~ +50 FPF20KU400TBER x x ~ 50/60 71/93 520/ ~ +55 FPF20KGU115BER x x Va.c. 50/60 107/ / ~ +55 FPF20KGU230BER x x Va.c. 50/60 114/ / ~ +55 Frequency Air Flow Temp. (V) (Hz) (W) (m³/h) ( C) OF-A12B23SWBAQ X119X V a.c. 50/60 21/21 163/ FPF20KGU400TBER x x ~ 50/60 105/ / ~ +55 FPF20KGU115BR x x Va.c. 50/60 120/ / ~ +55 FPF20KGU230BR x x Va.c. 50/60 140/ / ~ +55 FPF20KGU400TBR x x ~ 50/60 93/ / ~ +55 ( ) data with uncertainty of ±15%

4 6 7 Filter Fan Accessories Accessories Ambient Temperature Control Thermostats & Flash Device Replacement G3 & G4 Filter Media Filter media available in boxes of 6pcs in both IP54 (G3) & IP55 (G4) protection. FOR IP54 VERSION (G3) Description M08FPFK Fits FPF08/FF08 series Fan Filters M12FPFK M13FPFK M15FPFK M20FPFK FOR IP55 VERSION (G4) M12FPF5K M13FPF5K M15FPF5K M20FPF5K Fits FPF12/FF12 series Fan Filters Fits FPF13/FF13 series Fan Filters Fits FPF15/FF15 series Fan Filters Fits FPF20/FF20 series Fan Filters Fits FPF12/FF12 IP55 series Fan Filters Fits FPF13/FF13 IP55 series Fan Filters Fits FPF15/FF15 IP55 series Fan Filters Fits FPF20/FF20 IP55 series Fan Filters Mechanical thermostats and hygrostats for temperature and humidity regulation in electrical enclosures compatible with standard DIN rail application. Mechanical Thermostats C VERSION TRT-10A230V-NC TRT-10A230V-NO F VERSION TRT-10A230V-NCF TRT-10A230V-NOF Contact carrying capacity Setting Differential (referred to set point) Accuracy (Va.c.) 50/60Hz (A) (A) (K) (K) 10 (6*) ~ +80 ºC (6*) ~ +80 C + 4 if A if A>5 10 (6*) ~ +176 F (6*) ~ +176 F + 4 if A if A>5 NC = open on rise (red) NO = closed on rise (blue) * ( ) inductive load with cos = 0.6 Plastic Adaptors Allows a fan filter to sit up to 25mm on the outside of the cabinet leaving more space inside the enclosure. FPFA G FPFA G FPFA G SSC-08 SSC-12 SSC-13 SSC-15 SSC-20 Description Plastic adaptor RAL 7035 for FPF12 Plastic adaptor RAL 7035 for FPF15 Plastic adaptor RAL 7035 for FPF20 Stainless Steel Weather Protective Cover Also available as an economical powder coated RAL7035 Stainless Steel cover. Description steel cover for FPF08 and FF08 steel cover for FPF12 and FF12 steel cover for FPF13 and FF13 steel cover for FPF15 and FF15 steel cover for FPF20 and FF20 Twin Thermostats C VERSION TRT2-10A230V-NCNC TRT2-10A230V-NCNO TRT2-10A230V-NONO F VERSION TRT2-10A230V-NCNCF TRT2-10A230V-NCNOF TRT2-10A230V-NONOF NC = open on rise (red) Contact carrying capacity Setting Differential (referred to set point) Accuracy (Va.c.) 50/60Hz (A) (A) (K) (K) NO = closed on rise (blue) ~ +80 C ~ +80 C ~ +80 C -3 (NC) / +4 if A 5 +7 if A>5 (NO) +4 if A 5 +7 if A>5 (NO) ~ +176 F ~ +176 F ~ +176 F -3 (NC) / +4 if A 5 +7 if A>5 (NO) +4 if A 5 +7 if A>5 (NO) A4 Internal Document Holder TPD-A4 SSC-08 Description A4 Document Holder Flash Device Alerts the operator to live voltages within the cabinet and electrical systems using three flashing red lights. Temp. Single phase (Va.c.) 50/60Hz 3-phase FD ~ +70 ( C) FD ~ +70 FD ~ +70

5 8 9 Thermal Control Accessories Thermostats, Hygrostats, Compensation Devices & Limit Switches Effective thermal control increases the life of electrical components and expensive equipment inside an enclosure. Anti-Condensation Heaters Metallic, Touch Safe, Cabled & Terminal A variety of heaters for the thermo-regulation and prevention of condensation within electrical cabinets, connectable by cable or terminal block, with DIN rail fastening. Change-Over Mechanical Thermostats TRT-230V-S Mechanical Hygrostats Contact Setting Differential (referred to set point) (Va.c.) 50/60Hz (A) (A) (ºC) (K) (Heating) a.c. 10 (4*), d.c. 30W (Cooling) a.c. 5 (2*), d.c. 30W Setting 10 5 ~ 60 Differential (referred to set point) 4 1 (with thermal retroaction) * ( ) inductive load with cos = 0.6 Accuracy (Va.c.) 50/60Hz (A) (% RH) (% RH) (% RH) IGR35F ; ~ 90 5 ± 5 Compensation Devices Differences in air pressure inside and outside of the enclosure are minimised, which reduces the risk of condensation, whilst preventing the ingress of dirt and water. Protection Degree Fixing System Torque Cross Section Temp. Nm cm 2 ( C) CP-U55-00 IP55 PG29 Ø37mm ~ +70 HWM/HWP HTM/HTP HxL Heating power (W) METALLIC (HWM) OR PLASTIC (HWP) HEATERS WITH CABLE (Va.c.) 50/60 Hz (Vd.c.) Weight HWM005 78x49x HWM010 78x49x HWM015 78x49x HWM020 78x49x HWM025 78x49x HWM030 78x49x HWM x85x HWM x85x HWM x85x HWM x85x HWM x85x HWP x85x HWP x85x HWP x85x HWP x85x HWP x85x METALLIC (HTM) OR PLASTIC (HTP) HEATERS WITH TERMINAL BLOCK HTM x85x HTM x85x HTM x85x HTM x85x HTM x85x HTP x85x HTP x85x HTP x85x HTP x85x HTP x85x (Kg) Door Limit Switches Safety device for enclosures with or without manual reset, with roller plunger or adjustable lever. A.C A.C D.C D.C (V) 50/60Hz (A) (V) (A) Mechanical Durability Millions of operations FC FC FC FC SA-FC01K Plastic support for door limit switch fixing

6 10 11 Anti Condensation Heaters Metallic, Touch Safe, Cabled & Terminal Enclosure Lighting Fluorescent & LED Heating power voltage range Weight Compact fluorescent lamps for indoor installation and additional set of options from multiple connection cable to a magnetic mounting system. LED lamps with a metal fixing plate for an adjustable installation also available. HVMS HVPS METALLIC (HVMS) HEATERS WITH FAN (W) 50/60 Hz (Va.c.) HVMS x85x HVMS x85x HVMS x85x HVMS x85x HVMS150T x85x HVMS150T x85x HVMS x85x HVMS x85x HVMS200T x85x HVMS200T x85x HVMS250T x85x HVMS250T x85x HVMS350THP x85x HVMS350THP x85x PLASTIC (HVPS) HEATERS WITH FAN HVPS x85x HVPS x85x HVPS x85x HVPS x85x HVPS150T x85x HVPS150T x85x HVPS x85x HVPS x85x HVPS200T x85x HVPS200T x85x HVPS250T x85x HVPS250T x85x HVPS350THP x85x HVPS350THP x85x (Kg) FLL Series LED lamps FLL energy saving LED lamps with ON/OFF switch or PIR sensor to detect movement. Available with standard screw-in or alternatively, magnetic fastening for easy positioning (Code FLL-2MA) as below: Operating voltage range: Va.c. (FLL-120 series) Va.c. (FLL-230 series) Va.c. (FLL-300 series) Length Frequency LED Description (Va.c.) (Hz) (W) number color FLL U-IR /60 5.0/ K PIR sensor FLL U-S /60 5.0/ K ON/OFF switch FLL U-IR /60 5.0/ K PIR sensor FLL U-S /60 5.0/ K ON/OFF switch FLL U-IR /60 5.0/ K PIR sensor FLL U-S /60 5.0/ K ON/OFF switch Description FLL-2MA magnets kit (2pcs.) CLG-L Series LED Lamps CLG-L offers a metal bracket plate for an adjustable installation and is dual voltage (115V.a.c / 230V.a.c) Length Frequency (V a.c.) (Hz) (W) Number Color CLG-L /60 7.0/ K Fluorescent Lamps Economical compact fluorescent enclosure lights provide light where it is needed. These offer integrated on/off switch, quick & flexible mounting & modular connection capability. LED Length Frequency Light & Lamp Holder Cable Length (V a.c.) (Hz) (W) CLG-R T5 / G5 1,300 CLG-R T5 / G5 1,800 CLG-R T5 / G5 1,800 CLG-T T4 / G5 1,800 CLG-T T4 / G5 1,800 CLG-T T4 / G5 1,800 CLG-T T4 / G5 1,800 CLG-T T4 / G5 1,800 CLG-SS T8 / G13 - CLG-SF T8 / G13 - Description CONNECTION CABLE CVL CVL01A mm 300 mm

7 12 13 AC Axial Fans DC Axial Fans AC AXIAL FRAME FANS A wide range of standard and custom designed models for both AC and DC brushless axial and centrifugal frame fans, including solutions specific to different ambient conditions (IP55, all metal and high temperature resistant fans). Speed (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve A06G12HWBF00 60x60x Va.c. 5.3/4.0 14/17 18/27 2,200/2, /28.0 o A06G23HWBF00 60x60x Va.c. 6.0/4.5 14/17 17/27 2,400/3, /28.0 o A08A12HWxF00 80x80x Va.c. 14/11 36/41 40/55 2,600/3, /35.0 o o A08A23HWxF00 80x80x Va.c. 16/14 36/41 40/55 2,600/3, /35.0 o o A08B12HWxF00 80x80x Va.c. 14/12 41/51 40/55 2,500/3, /36.0 o o A08B12LWxF00 80x80x Va.c. 12/9.0 33/42 25/40 1,900/2, /32.0 o o A08B23HWxF00 80x80x Va.c. 14/12 41/51 40/55 2,500/3, /36.0 o o A08B23LWxF00 80x80x Va.c. 14/12 33/42 25/40 1,900/2, /32.0 o o A09A12HTxF00 92x92x Va.c. 14/11 56/68 37/54 2,500/3, /36.0 o o A09A23HTxF00 92x92x Va.c. 16/14 56/68 37/54 2,500/3, /36.0 o o A12W12HWBW00 113x113x Va.c. 20/18 150/167 66/81 2,650/2, /48.0 o A12W23SWBW00 113x113x Va.c. 22/21 165/200 67/94 2,700/3, /50.0 o A12Z12HWSW00 113x113x Va.c. 19/18 150/167 66/81 2,650/2, /48.0 o A12Z23HWxW00 113x113x Va.c. 18/18 148/182 65/80 2,550/2, /49.0 o o A12A12HTxF00 120x120x Va.c. 14/11 109/127 52/53 2,400/2, /42.0 o o A12A23HTBF00 120x120x Va.c. 16/14 109/127 52/53 2,400/2, /42.0 o A12B05HTBW00 120x120x38 24 Va.c. 14/14 154/165 62/77 2,650/2, /49.0 o A12B05HTSW00 120x120x38 24 Va.c. 13.2/ /142 55/50 2,530/2, /45.0 o A12B12HTxW00 120x120x Va.c. 20/18 136/168 57/80 2,750/3, /49.0 o o A12B12MTxW00 120x120x Va.c. 16/15 126/133 52/62 2,500/2, /46.0 o o A12B12STxW00 120x120x Va.c. 22/20 161/195 82/95 2,700/3, /50.0 o o A12B23ETSW00 120x120x Va.c. 6.5/6.0 85/83 19/16 1,500/1, /28.0 o A12B23HTXW00 120x120x Va.c. 20/19 148/182 65/80 2,750/3, /49.0 o o A12B23LTxW00 120x120x Va.c. 11/10 114/102 27/22 2,200/1, /42.0 o o A12B23MTxW00 120x120x Va.c. 16/15 133/143 35/52 2,400/2, /45.0 o o A12B23VTBW00 120x120x Va.c. 10/10 98/105 28/28 1,800/1, /35.0 o A12R23HTSW00 120x120x Va.c. 18/18 150/167 66/81 2,650/3, /54.0 o A13B12HTBF00 127x127x Va.c. 17/15 174/204 72/28 2,700/3, /50.0 o C17B12HTBF00 172x150x Va.c. 29/28 300/ /187 2,850/3, /58.0 o C17B23HTBF00 172x150x Va.c. 27/26 300/ /187 2,850/3, /58.0 o A17C12HWBF00 172x150x Va.c. 32/28 290/ /95 2,750/3, /55.0 o A17C23HWBF00 172x150x Va.c. 35/30 290/ /95 2,750/3, /55.0 o C17C12HTBF00 172x150x Va.c. 31/31 348/ /197 2,850/3, /58.0 o C17C23HTBF00 172x150x Va.c. 29/29 348/ /197 2,850/3, /58.0 o C18C12HTBF00 172x172x Va.c. 31/31 348/ /197 2,850/3, /55.0 o C18C23HTBF00 172x172x Va.c. 29/29 348/ /197 2,850/3, /55.0 o C22S12HKBD00 218x218x Va.c. 65/76 790/ /163 2,162/2, /67.4 o C22S23HKBD00 218x218x Va.c. 80/95 840/ /217 2,500/2, /68.0 o C22S40HKBD00 218x218x Va.c /72.7 o x = B (ball) or S (sleeve) - See end column for availability A selection of DC frame fans rated to IP20. This rating provides both dust and water protection with limited ingress being permitted. DC AXIAL FRAME FANS Speed (V) (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve D20E01LWBA00 20x20x10 5 Vd.c , o D20E01MWBA00 20x20x10 5 Vd.c , o D20E04LWBA00 20x20x10 12 Vd.c , o D20E04MWBA00 20x20x10 12 Vd.c , o D02E01HWBZ00 25x25x10 5 Vd.c , o D02E01MWBZ00 25x25x10 5 Vd.c , o D02E04HWBZ00 25x25x10 12 Vd.c , o D02E04MWBZ00 25x25x10 12 Vd.c , o D03E01LWBA00 30x30x10 5 Vd.c , o D03E01MWBA00 30x30x10 5 Vd.c , o D03E04LWBA00 30x30x10 12 Vd.c , o D03E04MWBA00 30x30x10 12 Vd.c , o D04E01HWxT00 40x40x10 5 Vd.c , o o D04E04MWxT00 40x40x10 12 Vd.c , o o D04E05HWxT00 40x40x10 24 Vd.c , o o D04E05MWxT00 40x40x10 24 Vd.c , o o D04E04HWST00 40x40x10 12 Vd.c , o D04E01MWST00 40x40x10 5 Vd.c , o D04F04HWxA00 40x40x15 12 Vd.c , o o D04F04LWxA00 40x40x15 12 Vd.c , o o D04F04MWxA00 40x40x15 12 Vd.c , o o D04D04HWBZ00 40x40x20 12 Vd.c , o D04D04MWxZ00 40x40x20 12 Vd.c , o o D04D05HWBZ00 40x40x20 24 Vd.c , o D04D05MWBZ00 40x40x20 24 Vd.c , o D04D04HWSZ00 40x40x20 12 Vd.c , o D04D05MWSZ00 40x40x20 24 Vd.c , o D04D05HWSZ00 40x40x20 24 Vd.c , o D45E01HWBA00 45x45x10 5 Vd.c , o D45E01MWBA00 45x45x10 5 Vd.c , o D45E04HWxA00 45x45x10 12 Vd.c , o o D45E04MWxA00 45x45x10 12 Vd.c , o o D45E01MWSA00 45x45x10 5 Vd.c , o D45E01HWSA00 45x45x10 5 Vd.c , o D50E04LWxA00 50x50x10 12 Vd.c , o o D50E04MWxA00 50x50x10 12 Vd.c , o o D50F04HWBA00 50x50x15 12 Vd.c , o D50F04SWxA00 50x50x15 12 Vd.c , o o D50F04LWSA00 50x50x15 12 Vd.c , o D50F04MWSA00 50x50x15 12 Vd.c , o D50F04HWSA00 50x50x15 12 Vd.c , o D06E01MWxT00 60x60x10 5 Vd.c , o o D06E04MWST00 60x60x10 12 Vd.c , o D06E04HWST00 60x60x10 12 Vd.c , o D06E01HWST00 60x60x10 5 Vd.c , o D06F01MWxA00 60x60x15 5 Vd.c , o o x = B (ball) or S (sleeve)

8 14 15 DC Axial Fans DC Axial Fans Speed (V) (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve D06F04MWxA00 60x60x15 12 Vd.c , o o D06F05HWBA00 60x60x15 24 Vd.c , o D06F05MWxA00 60x60x15 24 Vd.c , o o D06F04HWSA00 60x60x15 12 Vd.c , o D06F05HWSA00 60x60x15 24 Vd.c , o D06F01HWSA00 60x60x15 5 Vd.c , o D06D04HWxA00 60x60x20 12 Vd.c , o o D06D04LWxA00 60x60x20 12 Vd.c , o o D06D04MWxA00 60x60x20 12 Vd.c , o o D06D05LWxA00 60x60x20 24 Vd.c , o o D06D05MWxA00 60x60x20 24 Vd.c , o o D06A04LWBA00 60x60x25 12 Vd.c , o D06A04MWBA00 60x60x25 12 Vd.c , o D06A04SWBA00 60x60x25 12 Vd.c , o D06A05HWxA00 60x60x25 24 Vd.c , o o D06A05SWBA00 60x60x25 24 Vd.c , o D06A04HWSA00 60x60x25 12 Vd.c , o D06A04SWSA00 60x60x25 12 Vd.c , o D06A04LWSA00 60x60x25 12 Vd.c , o D06A04MWSA00 60x60x25 12 Vd.c , o D06A05SWSA00 60x60x25 24 Vd.c , o D06A05LWSA00 60x60x25 24 Vd.c , o D06A05MWSA00 60x60x25 24 Vd.c , o D07A04MWxA00 70x70x25 12 Vd.c , o o D07A05HWxA00 70x70x25 24 Vd.c , o o D07A05MWxA00 70x70x25 24 Vd.c , o o D07A04HWSA00 70x70x25 12 Vd.c , o D08F01MWxA00 80x80x15 5 Vd.c , o o D08F04HWxA00 80x80x15 12 Vd.c , o o D08F04MWBA00 80x80x15 12 Vd.c , o D08F05MWxA00 80x80x15 24 Vd.c , o o D08F04MWSA00 80x80x15 12 Vd.c , o D08F05HWSA00 80x80x15 24 Vd.c , o D08F01HWSA00 80x80x15 5 Vd.c , o D08D04HWBA00 80x80x20 12 Vd.c , o D08D04MWxA00 80x80x20 12 Vd.c , o o D08D05HWBA00 80x80x20 24 Vd.c , o D08D05MWxA00 80x80x20 24 Vd.c , o o D08D04HWSA00 80x80x20 12 Vd.c , o D08D05HWSA00 80x80x20 24 Vd.c , o D08A04HWBA00 80x80x25 12 Vd.c , o D08A04LWxA00 80x80x25 12 Vd.c , o o D08A04MWBA00 80x80x25 12 Vd.c , o D08A04SWxA00 80x80x25 12 Vd.c , o o D08A05HWBA00 80x80x25 24 Vd.c , o D08A05MWBA00 80x80x25 24 Vd.c , o D08A05SWxA00 80x80x25 24 Vd.c , o o D08A04MWSA00 80x80x25 12 Vd.c , o D08A04HWSA00 80x80x25 12 Vd.c , o Speed (V) (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve (V) (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve DO8A05MWSA00 80x80x25 24 Vd.c , o DO8A05LWSA00 80x80x25 24 Vd.c , o DO8A05HWSA00 80x80x25 24 Vd.c , o DO9D04MWxA00 92x92x20 12 Vd.c , o o DO9D05MWxA00 92x92x20 24 Vd.c , o o D09D04HWSA00 92x92x20 12 Vd.c , o D09D05HWSA00 92x92x20 24 Vd.c , o D09A04EWBZ00 92x92x25 12 Vd.c , o D09A04HWxZ00 92x92x25 12 Vd.c , o o D09A04LWxZ00 92x92x25 12 Vd.c , o o D09A04MWxZ00 92x92x25 12 Vd.c , o o D09A04SWBZ00 92x92x25 12 Vd.c , o D09A05HWBZ00 92x92x25 24 Vd.c , o D09A05LWxZ00 92x92x25 24 Vd.c , o o D09A05MWxZ00 92x92x25 24 Vd.c , o o D09A05SWBZ00 92x92x25 24 Vd.c , o D09A04SWSZ00 92x92x25 12 Vd.c , o D09A05SWSZ00 92x92x25 24 Vd.c , o D09A05HWSZ00 92x92x25 24 Vd.c , o D12A04LWBZ00 120x120x25 12 Vd.c , o D12A04MWBZ00 120x120x25 12 Vd.c , o D12A04SWxZ00 120x120x25 12 Vd.c , o o D12A05HWBZ00 120x120x25 24 Vd.c , o D12A05LWxZ00 120x120x25 24 Vd.c , o o D12A05MWxZ00 120x120x25 24 Vd.c , o o D12A05SWBZ00 120x120x25 24 Vd.c , o D12A04MWSZ00 120x120x25 12 Vd.c , o D12A04HWSZ00 120x120x25 12 Vd.c , o D12A04LWSZ00 120x120x25 12 Vd.c , o D12A05HWSZ00 120x120x25 24 Vd.c , o D12A05SWSZ00 120x120x25 24 Vd.c , o D12G05HWBA00 120x120x32 24 Vd.c , o D12B04HWBZ00 120x120x38 12 Vd.c , o D12B04LWBZ00 120x120x38 12 Vd.c , o D12B04SWxZ00 120x120x38 12 Vd.c , o o D12B05HWxZ00 120x120x38 24 Vd.c , o o D12B05LWxZ00 120x120x38 24 Vd.c , o o D12B05MWxZ00 120x120x38 24 Vd.c , o o D12B05SWBZ00 120x120x38 24 Vd.c , o D12B07HWBZ00 120x120x38 48 Vd.c , o D12B07LWxZ00 120x120x38 48 Vd.c , o o D12B07MWBZ00 120x120x38 48 Vd.c , o D12B04LWSZ00 120x120x38 12 Vd.c , o D12B04MWSZ00 120x120x38 12 Vd.c , o D12B04HWSZ00 120x120x38 12 Vd.c , o D12B05HWSZ00 120x120x38 24 Vd.c , o D12B05SWSZ00 120x120x38 24 Vd.c , o D12B07MWSZ00 120x120x38 48 Vd.c , o D12B07HWSZ00 120x120x38 48 Vd.c , o D22S07HKBD00 218x218x83 48 Vd.c , , o x = B (ball) or S (sleeve)

9 16 17 Special IP55 Fans Where the application calls for something more robust, we offer a selection of special frame fans varying from IP55 protected to high temperature rates and all metal construction. Special IP55 Fans Where the application calls for something more robust, we offer a selection of special frame fans varying from IP55 protected to high temperature rates and all metal construction. ATEX, EC & IP68 Frame Fans IP55 DC FRAME FANS Speed (V) (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve D04D04HWBZF0 40x40x20 12 Vd.c , o D04E05MWBTF0 40x40x10 24 Vd.c ,5 19 4, o D06A04LWBAF0 60x60x25 12 Vd.c , o D06A05HWBAF0 60x60x25 24 Vd.c , o D06A05SWBAF0 60x60x25 24 Vd.c , o D07A04HWBAF0 70x70x25 12 Vd.c , o D08A04HWBAF0 80x80x25 12 Vd.c , o D08A04LWBAF0 80x80x25 12 Vd.c , o D08A05HWBAF0 80x80x25 24 Vd.c , o D08A05MWBAF0 80x80x25 24 Vd.c , o D08A05SWBAF0 80x80x25 24 Vd.c , o D09A04HWBZF0 92x92x25 12 Vd.c , o D09A05HWBZF0 92x92x25 24 Vd.c , o D09A05LWBZF0 92x92x25 24 Vd.c , o D09A05SWBZF0 92x92x25 24 Vd.c , o D12A04HWBZF0 120x120x25 12 Vd.c , o D12A04LWBZF0 120x120x25 12 Vd.c , o D12A05HWBZF0 120x120x25 24 Vd.c , o D12A05HWBZFW80 120x120x25 24 Vd.c , o D12A05SWBZF0 120x120x25 24 Vd.c , o D12B04HWBZF0 120x120x38 12 Vd.c , o D12B05HWBZF0 120x120x38 24 Vd.c , o Special DC fans are subject to Minimum order quantities & additional lead times. Contact us for more information Available in standard sized frame 120x120x38mm, the HEC range of axial fans is ATEX certified, is powered by an energy efficient EC motor and has an ingress protection level to IP68. IP55 AC FRAME FANS Speed (V) (W) (m³/h) (Pa) (RPM) [(db(a)] Ball Sleeve A08B12HWBFF0 80x80x Va.c. 14/12 41/51 40/55 2,500/3, /36.0 o A08B23HWBFF0 80x80x Va.c. 14/12 41/51 40/55 2,500/3, /36.0 o A12W23HWBWF0 113x113x Va.c. 20/19 150/180 66/80 2,550/2, /49.0 o A12Z23HWBWF0 113x113x Va.c. 18/18 140/155 62/75 2,600/2, /45.0 o A12B12HWBWF0 120x120x Va.c. 20/18 136/168 57/80 2,750/3, /49.0 o A12B23HWBWF0 120x120x Va.c. 20/19 148/182 65/80 2,750/3, /49.0 o A12B23LWBWF0 120x120x Va.c. 11/10 114/102 27/22 2,200/1, /42.0 o A12B23STBWF0 120x120x Va.c. 24/22 143/199 62/97 2,700/3, /50.0 o ALL METAL AC FRAME FANS A09B12HWBM00 92x92x Va.c. 12/11 75/87 59/74 2,700/3, /42.0 o A09B23HWBM00 92x92x Va.c. 12/11 75/87 59/74 2,700/3, /42.0 o A12B12HTBM00 120x120x Va.c. 17/15 151/175 64/59 2,700/3, /46.0 o A12B12LTBM00 120x120x Va.c. 17/15 107/114 25/22 2,000/2, /35.0 o A12B23HTBM00 120x120x Va.c. 17/15 151/175 64/59 2,700/3, /46.0 o A12B23LTBM00 120x120x Va.c. 17/15 107/114 25/22 2,000/2, /35.0 o A17M12SWBM00 172x150x Va.c. 42/42 332/ /157 2,800/3, /53.0 o A17M23SWBM00 172x150x Va.c. 42/42 332/ /157 2,800/3, /53.0 o A17T12SWBM00 172x150x Va.c. 45/45 383/ /126 2,750/3, /61.0 o A17T23SWBM00 172x150x Va.c. 45/45 383/ /126 2,750/3, /61.0 o HIGH TEMPERATURE AC FRAME FANS A09B12HWBMT0 92x92x Va.c. 12/11 75/87 59/74 2,700/3, /42.0 o A09B23HTBMT0 92x92x Va.c. 12/11 75/87 59/74 2,700/3, /42.0 o A17M12SWBMT0 172x150x Va.c. 42/42 332/ /157 2,800/3, /53.0 o A17M23SWBMT0 172x150x Va.c. 42/42 332/ /157 2,800/3, /53.0 o A17T12SWBMT0 172x150x Va.c. 45/45 383/ /123 2,750/3, /61.0 o A17T23SWBMT0 172x150x Va.c. 45/45 383/ /123 2,750/3, /61.0 o EC (ELECTRONICALLY COMMUTATED) FRAME FANS E08B12HWBL00 80x80x Va.c. 5.0/5.0 64/68 46/53 2,800/3, /37.0 o E08B23HWBL00 80x80x Va.c. 5.0/5.0 68/73 53/61 3,000/3, /39.0 o Ideal for both refrigeration, where carbon gases may be present and any other potentially hazardous environment, the ATEX certified range gives confidence to users by incorporating a fully encapsulated motor and sparkproof components. Available in three speeds, low, medium and high, the HEC range is exclusive to Axair Fans and UK stocking. E12B23HWBL00 120x120x Va.c. 6.0/ /206 79/77 3,000/3, /46.8 o E12B23HWBLF0 120x120x Va.c. 5.8/ /200 70/75 2,735/2, /46.8 o E12B23LWBL00 120x120x Va.c. 2.5/ /138 32/37 2,000/2, /35.7 o E12B23MWBL00 120x120x Va.c. 4.0/ /176 55/58 2,500/2, /41.8 o Size Speed. Air Flow (V) (V) (rpm) (A) (Wa) (m3/h) (Pa) (db(a) HEC1238HA 120x120x38 115/ HEC1238MA 120x120x38 115/ HEC1238LA 120x120x38 115/

10 18 19 Frame Fan Accessories Notes From metal guards to powers leads, we have all the accessories required. Contact us for more information should you need advice on which part is required. Metal Fan Guards Plastic Fan Guards MFG (ø mm) /S MFG MFG Plastic Filters F40/MR 46.4x 46.4 F60/MR 64x64 F80/MR 86x86 F92/MR 97x97 F120/MR 126x126 F150/MR 179x179 Spare Filter Media M40 42x42 M60 60x60 M80 81x81 M92 92x92 M x120 M x172 Elastic Rivets EAR4401N PFG G x42.3 G60 60x60 G80 81x81 G92 92x92 G x121 G x173 Fast Assembly Plastic Fan PFG G120/S 120x120 Metal Fan Guard G120M x120 Metal Filters FM/60 60x60 FM/ x83.8 FM/92 92x92 FM/ x119 FM/ x182 Fan Leads straight version 45 version Length of cable C24 C C36 C C60 C ,520 C80 C ,032 C100 C ,540 C118-3,000 Plasic Rivets Round flat head version V-shaped head version RAL colour FAR175TPN FAR175TSN 9005 Black FAR175TPR FAR175TSR 7032 Grey FAR225TPN FAR225TSN 9005 Black FAR225TPR FAR225TSR 7032 Grey

11 8 Lowfield Drive Centre 500 Wolstanton newcastle-under-lyme st5 0uu Axair Fans UK Limited

Systems and components for industrial enclosures. Edition 2018/1

Systems and components for industrial enclosures. Edition 2018/1 Systems and components for industrial enclosures Edition 2018/1 10 13 33 04 32 30 31 28 14 31 11 26 04-13 FAN FILTERS AND ROOF UNITS Air filtering solutions for enclosures. 28-29 THERMOELECTRIC COOLING

More information

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance Technic Cross-Flow Fans T R A N S F O R M E R C O O L I N G S O L U T I O N S Transformer Cross-Flow Fans General Information provides optimal solutions for air forced cooling of transformers. High performance

More information

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop

More information

Features. Specifications. Finish. Notes

Features. Specifications. Finish. Notes Spec-00732 BPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt N36 / BTU/Hr.

More information

Roof-mounted Blue e+ cooling unit Integration solution VX25

Roof-mounted Blue e+ cooling unit Integration solution VX25 Roof-mounted Blue e+ cooling unit Integration solution VX25 Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ Cooling unit with 1.3 kw and Blue e+ technology with

More information

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL

More information

INDICATOR LAMPS & LED REPLACEMENT LAMPS

INDICATOR LAMPS & LED REPLACEMENT LAMPS INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC

More information

DIGITUS WALL MOUNT ENCLOSURE

DIGITUS WALL MOUNT ENCLOSURE Product Picture: Product Description: The DIGITUS Compact Series is a range of 19" wall mount enclosures developed for installation of both cabling and equipment. The enclosures are special designed to

More information

LAMPS & INDICATOR LAMPS

LAMPS & INDICATOR LAMPS LAMPS & INDICATOR LAMPS 10.5 M16 x 1.0 55-056-0 Bulk 12V140mA lead wire lamp 55-056-2 Display Package (2) 19.5 14.0 12.0 20.4 7.5 50.4 55-120-0 Bulk NE-2 Neon bulb 55-120-2 Display Package (2) T 3-14 (10mm)

More information

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ SoliTherm Control Cabinet Air Conditioning...wegweisend innovativ Table of Content Page ComPact cooling unit series 06 ComPact cooling units 07-15 SlimLine cooling unit series 16 SlimLine cooling units

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

Flexibility and Safety. BERNSTEIN safety hinge switches

Flexibility and Safety. BERNSTEIN safety hinge switches Flexibility and Safety BERNSTEIN safety hinge switches BERNSTEIN safety hinge switches Advantages of safety hinge switches in comparison to traditional door contacts Easy to install and tamper-resistant

More information

TUC: Universal thermostat

TUC: Universal thermostat Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm 21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature

More information

Axial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management

Axial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category A4AXFN24 4", 24VDC Cooling Fan Hoffman Enclosures,

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Immersion Pumps HCT (High Chem) sealless

Immersion Pumps HCT (High Chem) sealless Immersion Pumps HCT (High Chem) sealless 1-6004-US Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature

More information

T BTU/Hr Watts

T BTU/Hr Watts T-SERIES LARGE CAPACITY OUTDOOR T62 20000 BTU/Hr. 5860 Watts T70-36 36000 BTU/Hr. 10548 Watts T70-60 59000 BTU/Hr. 17287 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453

More information

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dimensions Technical Data Ambient temperature 5-40 C Cooling method, standard

More information

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts. 763.576.3200 Spec-00614 I763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners PROAIR Harsh Environment CR23 1600 BTU/Hr. 469 Watt CR29 2700 and 4000 BTU/Hr.

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

Outdoor Cabinets. Protection against all weather conditions. capability flexibility reliability. Product Catalog.

Outdoor Cabinets. Protection against all weather conditions. capability flexibility reliability. Product Catalog. Outdoor Cabinets Protection against all weather conditions capability flexibility reliability Product Catalog www.conteg.com outteg Outdoor Cabinets Don`t compromise. You can benefit from the advantages

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Küba comfort DP. Draught-free ventilation and extremely quiet operation Draught-free ventilation and extremely quiet operation engineering for a better world GEA Heat Exchangers Draught-free ventilation and extremely quiet operation Low air speed in the cold room Integrated

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

Data Sheet IP67 Mast Enclosure

Data Sheet IP67 Mast Enclosure Data Sheet IP67 Mast Enclosure Pre-assembled outdoor housing for mast mounting Features With the IP67 mast box, MICROSENS offers a pre-assembled, compact chassis which is ideally suited for the integration

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC

More information

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories Spec-00301 EPH FX (763) 422-2600 422-2211 Thermal Management CR Compact, Mid-Size and Full-Size and Accessories Industry Standards Refer to tables for specific UL/cUL Type ratings these air conditioners

More information

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C : Product Overview Keeps its cool during peak heat loads and hot weather A/C Indoor/Outdoor Air Conditioners Chapter Contents PRODUCT OVERVIEW T15 Model 800 BTU...43 Indoor/Outdoor Air Conditioners...42

More information

G1-M1 (Protection Relay)

G1-M1 (Protection Relay) G1-M1 (Protection Relay) Defining G1 and M1 series protection relays in simple terms G1 and M1 series protection relays are the automation devices which measures electrical values and detects failures.

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

with additional normally-open signalling contact l With integrated AS interface Safety at Work. Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

T BTU/Hr Watts

T BTU/Hr Watts T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R,

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

WCHE BTU/Hr Watts

WCHE BTU/Hr Watts 763.576.3200 SPEC-01037 A763.422.2211 COOLING SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR HEAT EXCHANGERS WCHE01 2968 BTU/Hr. 870 Watts

More information

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts Industry Standards UL/cUL Listed; Type 12, 3R,

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

Safe Enclosure Cooling

Safe Enclosure Cooling Safe Enclosure Cooling Heat Exchangers 2017 www.seifertsystems.com Table of Contents Page Product Overview 3 Air / water heat exchangers 4-18 Air / air heat exchangers 19-25 Thermal Management solutions

More information

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors 00/00/400/600 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Engineering Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division factory-sealed LED luminaire for general illumination High-performance, high-brightness Hazard Gard EVLL LED Luminaire

More information

2.9 Sigma/ 2 Plunger Metering Pumps

2.9 Sigma/ 2 Plunger Metering Pumps .9 Sigma/ Plunger Metering Pumps.9Sigma/ Plunger Metering Pumps.9.1 Sigma Plunger Metering Pumps The Sigma/ motor plunger metering pump has a high-strength inner metal housing for those component parts

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners PH FX ( Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 74 74 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

MIKRO POWER FACTOR CORRECTION COMPONENTS

MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

Actuators IC 20, IC 40

Actuators IC 20, IC 40 Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions

More information

XR47-24 Models 24 W/ F (43 W/ C)

XR47-24 Models 24 W/ F (43 W/ C) CLIMAGUARD AIR-TO-AIR INDOOR XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8 W/ F (14 W/ C) XR29-18 Models 18 W/ F (32 W/ C) XR47-24 Models 24 W/ F (43 W/ C) XR47-35 Models 35 W/ F (63 W/ C) XR60-55 XR60-84

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications. Solenoid s Inline s IV Nominal diameter 3 mm Suitability for Industry-Specific Applications Applications Inline valve for deactivation of unused suction pads Individual control of the suction pads of a

More information

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

1 Inductive proximity switches. 5 Connecting cables. Highlights: New: Highlights: - All-metal housings - Miniature sizes - Long operating distances - Extreme environmental conditions - Analog outputs New: - All-metal devices for food industry and sea-water applications -

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

HOG 86. The incremental HeavyDuty encoder for highest demands

HOG 86. The incremental HeavyDuty encoder for highest demands HOG 86 The incremental HeavyDuty encoder for highest demands Extremely robust. Failsafe in any environment The solid, extremely sturdy housing with minimum 10 mm wall thickness is a prerequisite design

More information

POWER FACTOR CORRECTION

POWER FACTOR CORRECTION Main Catalogue 2015 POWER FACTOR CORRECTION POWER QUALITY ENERGY MANAGEMENT FRAKO Leading-edge quality for reliable power supply networks FRAKO's mission is to provide solutions that are designed and

More information

Optical Signal Devices. Free-standing Beacons

Optical Signal Devices. Free-standing Beacons Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

Okta 1000, Roots pump without motor

Okta 1000, Roots pump without motor Okta 1000, Roots pump without motor Okta 1000, Roots pump without motor Similar Image High-performance Roots pump with a pumping speed of 590 to 1,775 m 3 /h Without motor (coupling and motor lantern are

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dual-stage, high-performance rotary vane pump with a pumping

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry. Safety along the complete line: 3SE7 cable-operated switches Answers for industry. Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product range,

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24 GRASSLIN - MIL 72 SERIES (24-Hour, 7-Day) 24-HOUR TIME CONTROL SYNCHRONOUS WITHOUT OVERRIDE WITH 3-WAY OVERRIDE QUARTZ 7-DAY CARRY-OVER**With 3-Way Override Time based control of lighting, ventilating,

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

Agilent High Capacity RV Pumps & Roots Pumping Systems

Agilent High Capacity RV Pumps & Roots Pumping Systems Agilent High Capacity RV Pumps & Roots Pumping Systems 2-3 MS-Series Rotary Vane Pumps 4-5 RPS-Series Roots Pumping Systems and RPK-Series Roots Pumping Kits 6-7 Typical Applications 8-15 Pump Models MS-Series

More information

SERIES 400 SERIES 620

SERIES 400 SERIES 620 x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x

More information

Immersion Pumps HCT (High Chem) sealless EN

Immersion Pumps HCT (High Chem) sealless EN Immersion Pumps HCT (High Chem) sealless 1 6004 EN Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

GRUNDFOS alldos product information. The solution for complex dosing tasks

GRUNDFOS alldos product information. The solution for complex dosing tasks GRUNDFOS alldos product information The solution for complex dosing tasks Measurements Measurements a h d Electric actuator b Pneumatic actuator g e Ø 9mm k f i m 1 m 2 k j c n l 1 l 2 DMH model Measurements

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 115 Cooling incubators with thermoelectric cooling Model KT 115 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Refrigerated incubators with thermoelectric refrigeration Model KT 53 Refrigerated incubators with thermoelectric refrigeration The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Connectivity accessories by Nestor Cables

Connectivity accessories by Nestor Cables Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com

More information