KARIN Operator manual WinKARIN 3.X

Size: px
Start display at page:

Download "KARIN Operator manual WinKARIN 3.X"

Transcription

1 HIRSCHMANN Rheinmetall Elektronik KARIN Operator manual WinKARIN 3.X Print: 3.0/98 01/BN_1405E

2 Contents Contents Introduction 1-1 General notes Technical modifications Limited liability Copyright Customer service Explanation of warning and note symbols General Terminology System survey General Local Monitoring Remote monitoring Remote monitoring Installation 2-1 System requirements Installation Windows 3.X Windows Start Requirements Start of the monitoring program Configuration Preferences Channel configuration WinKARIN 3.X ü

3 Contents Operation 3-1 General Menu structure File View Mode Tools Definitions Help Changes 4-1 Appendix 5-1 ü WinKARIN 3.X 0-3

4 Introduction General notes Technical modifications The information in this manual is subject to change at any time. Limited liability We do our very best to provide customers with reliable state-of-the-art technology. However, we can neither guarantee that this program can be executed on any PC irrespective of its particular configuration nor take responsibility for any unforeseen disadvantage (loss of use, loss of software, interruption of business or other) resulting from applying this software. Copyright This manual contains information protected by copyright. All rights reserved. No part of this manual may be photocopied, otherwise reproduced or translated into another language without the prior written consent of. ATTENTION: Keep this manual handy all the time. 1-2 WinKARIN 3.X ü

5 Introduction Explanation of warning and note symbols WARNING: Indicates that ignorance or bad neglicence of the cautionary measures listed may result in personal injury or equipment damage. ATTENTION: Indicates that ignorance or bad neglicence of the cautionary measures listed may result in device damage. NOTE: Useful tips and information on practical application. 1-4 WinKARIN 3.X ü

6 Introduction General This manual gives you a general and straightforward survey of the WinKARIN system design and the program layout. You will find detailed information about the practical aspects of the WinKARIN monitoring software in the on-line help file of the program itself. By the way, do not miss having a look at the status line, as it delivers useful advice, too. Most specific information, in particular information about commands for the spare channel configuration (N+1) is packed into a special on-line help file that is accessible via a hotspot in the block-diagrams of the modules concerned. WinKARIN comes with a couple of utilities. These utilities are not dealt with in this manual. See the on-line help file of the WinKARIN Utilities and the readme.txt file of the KARIN Utilities for specific information about these utilities. If you cannot find a good answer to your question in the manual, the on-line help, the readme files and the status line, please contact your customer service. NOTE: For the installation and start-up of the monitoring program good knowledge of PC, Microsoft WINDOWS and modem handling in general and familiarity with online help-files in particular is required. ü WinKARIN 3.X 1-5

7 Introduction Terminology Monitoring modes Listener Master Extended Master Display modes Headend Modules Channels Module menu The monitoring program can be operated in three modes, "Listener", "Master" and "Extended Master", which are optimized for specific purposes and hardware requirements. Monitoring mode with the most restrictions. A PC in the Listener mode cannot send, but only receive data. It follows from this that switches in the KARINheadend cannot be set in this mode. Monitoring mode that is marked by mutual communication between the PC and the KARIN headend. A bidirectional connection with the headend is needed. Monitoring mode that enables the user to set switches in the KARIN headend. The monitoring program is capable of displaying the KARIN headend in the modes "Headend", "Modules" and "Channels", emphasizing different functional aspects of the headend. Display mode in which the KARIN headend is displayed according to its mechanical design. Display mode in which the KARIN headend is represented as a list of module types. Display mode in which the KARIN headend is represented as a list of configurated channels. For each monitored module there is a module menu. It includes the front-panel and the block-diagram of the module with the measured values. It may also include one or more switches and editing fields. Module address Each module has a module address of its own (e.g. rack 2 / main frame 5 / module 8). Channel name Limit exceedings Rack system Range of compact devices Data modem RF-modem A channel name (e. g. CNN) can be assigned (see also channels) to modules that are involved in processing the same channel.. For each measured value a lower and a higher limit can be defined. If one of these values is exceeded, a warning (limit exceeding) is indicated. KARIN headend consisting of racks and including a data modem. KARIN compact main frame with a RS 232 interface on the front-panel of the power-supply. Central monitoring unit in the KARIN-headend. Monitoring a headend is not possible without a data modem. Component of the KARIN system that must be installed in order to enable communication (PC <---> KARIN) via the RF-network. 1-6 WinKARIN 3.X ü

8 Introduction System survey General The KARIN-PC-monitoring program comprises the following functional units: z z z z z z z z Access to headend information from different points-of-view Localisation of module errors and their causes Level control without measuring equipment Functional display of modules by clear-to-see block-diagrams. Module assignments to channels (channel configuration) Switch settings via block-diagrams Recording of errors, configuration changes, measured values and limit exceedings. Printing of recorded and other important information The software is prepared for both local and remote monitoring (see below). ü WinKARIN 3.X 1-7

9 DATA MODEM +24V. -12V. ON. OFF. POWER SUPPLY RS232 VIDEO OUT. MUTE. 2.IF BB. VIDEO BB. AF SAT RECEIVER AF SUBCARRIER DEMODULATOR RF DEV. RF -20dB. AF FM MODULATOR RF DEV. RF -20dB AF FM MODULATOR AGC 2. [db] VIDEO VIDEO PROCESSOR IF -20dB. AF VISION/SOUND MODULATOR SOUND 2 MODULATOR RF. IF 1. IF 2. RF -30dB. UP CONVERTER 1.IF 0dB. SAT SPLITTER Introduction Local Monitoring When the headend is monitored locally, the PC communicates directly through the RS232 interface with the KARIN-headend. For the rack configuration the RS232 interface is integrated into the data modem, for the main frame configuration it is integrated into the power supply (see "Connection of the PC" for more details). Rack Configuration Main Frame Configuration Output Ampl. I Output Ampl. II Data Mod. Pilot I Pilot II (Reserve) SAT-Splitter SAT-Splitter SAT-Splitter Output Comb. MAINS. +12V VIDEO. VIDEO. CARRIER 1. CARRIER 2. CARRIER 3. CARRIER 4. RF OUT. RF OUT. REM.AUX. AGC 1. MANUAL. VIDEO. TEST LINE. REM.MAIN. VIDEO IN DEVIATION SOUND DATA LINE. REMOTE. MONO. STEREO. 2-SOUND. RF OUT. LNC POWER. SAT-Receiv. Subcarr.Demod SAT-Receiv. Subcarr.Demod SAT-Receiv. Subcarr.Demod SAT-Receiv. Subcarr.Demod SAT-Receiv. Subcarr.Demod SAT-Receiv. Subcarr.Demod V-Proc. V-Proc. V/S-Mod. V/S-Mod. Up-Con. Mod. 2 2 Up-Con. Mod. blank blank V-Proc. V-Proc. Up-Con. Mod. V/S-Mod. V/S-Mod. 2 2 blank blank V-Proc. V-Proc. Up-Con. Mod. Up-Con. Mod. V/S-Mod. V/S-Mod. 2 2 blank blank Up-Con. Mod. RS232 RS232 RS Remote Supply RS Remote Supply PS PS Local monitoring Rack configuration The communication between the PC and the headend takes place via the serial interface of the data modem. REMOTE 1. REMOTE 2. data modem RS232 RS232 COM1 (COM2) Connection data modem <--> PC 1-8 WinKARIN 3.X ü

10 RS232 DATA MODEM MAINS. +12V. +24V. -12V. ON. OFF. POWER SUPPLY RS OUT. MUTE. 2.IF VIDEO. BB. VIDEO BB. AF SAT RECEIVER AF SUBCARRIER DEMODULATOR RF DEV. RF -20dB. AF FM MODULATOR RF DEV. RF -20dB AF VIDEO. AGC 1. AGC 2. [db] VIDEO FM MODULATOR VIDEO PROCESSOR SOUND IF -20dB. AF VISION/SOUND MODULATOR MONO. STEREO. SOUND 2 MODULATOR RF. IF 1. IF 2. RF -30dB. UP CONVERTER 1.IF 0dB. SAT SPLITTER Introduction Main frame configuration The communication between the PC and the headend (compact device) takes place via the serial interface in the power supply unit. Power Supply COM1 (COM2) Remote monitoring RS232 Connection compact device <--> PC VIDEO. VIDEO CARRIER 1. CARRIER 2. CARRIER 3. CARRIER 4. RF OUT. RF OUT. TEST LINE. REM.MAIN. REM.AUX. MANUAL. VIDEO IN DEVIATION DATA LINE. REMOTE. 2-SOUND. RF OUT. LNC POWER. Remote monitoring The PC can be located at any place, but must be able to communicate with the headend. Communication can take place either z via the CATV network or z via the public telephone network with a terminal remote programme or z via the public telephone network with a Remote Control Interface (FUS). Communication via the CATV network For the communication via the CATV network a RF modem is needed. If the reverse channel is equipped, switchings in the system can be carried out. In this case the RF modem is inserted between the PC and the RF cable. This way of monitoring can only be applied to rack systems. KARIN headend REMOTE 1. REMOTE 2. CATV network RF modem monitoring station monitoring PC ü Data modem Communication via the CATV network ü WinKARIN 3.X 1-9

11 RS232 DATA MODEM RS232 DATA MODEM Introduction Communication via the public telephone network For the communication via the public telephone network another PC and another telephone modem is needed. At the monitoring station a telephone network is required as well. The PC at the headend is controlled by the terminal remote program of the PC in the remote monitoring station. KARIN headend REMOTE 1. REMOTE 2. local PCs ü telephone modem public telephone network telephone modem monitoring station monitoring PC ü Data modem Communication via the public telephone network Communication via the public telephone network with the FUS For the use of the Remote Control Interface (FUS) and the communication via the public telephone network the program WinKARIN Remote Control is needed. The Remote Conntrol interface (FUS) gives access to the KARIN-bus and, as a result, to equipment data. Through WinKARIN Remote Control an online connection between the Remote Control Interface (FUS) and the terminal PC can be built up via telephone modems. KARIN headend REMOTE 1. REMOTE 2. FUS telephone modem public telephon network telephone modem monitoring station monitoring PC ü Communication via the public telephone network with the FUS 1-10 WinKARIN 3.X ü

12 Installation System requirements Minimum equipment The PC system must meet the following requirements: z Pentium 120 MHz with z PCI bus z 3.5" floppy disc z Mouse z Keyboard z Serial interface COM 1 or COM 2 with or UART chip z Parallel interface LPT1 or LPT2 ( printer connection) z At least 16 MB RAM z Hard disc with a capacity of 120 MB. z VGA-monitor (17 inches, 800*600 points) z Interface-cable 9 poles, shielded, cores connected through 1:1 (see "interface cable") z DOS 5.0 or higher z Windows 3.1 / 3.11 Recommended equipment The PC system must meet the following requirements: z Pentium 200 MHz with z PCI bus z 3.5" floppy disc z Bus mouse z Keyboard z Serial interface COM 1 or COM 2 with or UART chip z Parallel interface LPT1 or LPT2 ( printer connection) z 32 MB RAM z Hard disc with a free capacity of at least 20 MB. z VGA-monitor (20 inches, 1152*864 points) z Interface-cable 9 poles, shielded, cores connected through 1:1 (for the connection PC <-> data modem and PC <-> RF-modem resp.) z DOS 6.2 z Windows 3.1 / 3.11 oder Windows95 NOTE: For remote control via the public telephone network this is the minimum equipment. KARIN2 specifications A number of advanced features of WinKARIN (frequency setting, file transfer to modules, channel configuration, spare channel configuration) requires that your headend is compatible with KARIN 2 specifications. This implies that you must have a data modem of the DM502 type or higher and data processors of the DP502 type or higher to utilize these functions. To avoid any troubles we would like to recommend replacing old data processors by data processors of the DP502 type or higher. 2-2 WinKARIN 3.X ü

13 Installation If you, however, prefer a combination of data processors DP501 and DP502 or higher to a uniform solution, make sure that the appropiate data processor is installed in the main frame to work with a KARIN 2 module. Otherwise the functions of the module will be reduced or the module will not work at all. See the compatibility list you can find in the appendix and the release notes for the latest news about the functional relationship between data modem and data processors on the one hand and modules on the other hand.. NOTE: Generally speaking, a headend that is equipped with at least a data modem DM501 and one or more data processors DP501 must be considered a KARIN 1 headend, to which advanced WinKARIN functions cannot be applied. ATTENTION: The Remote Control Interface (FUS), which communicates with WinKARIN Remote Control, is a K2 module! Therefore complete equipment of the rack with data processors DP 502 or higher is required. ü WinKARIN 3.X 2-3

14 Installation Installation ATTENTION: For the correct configuration of WinKARIN Remote Control the complete study of all relevant operating/operator manuals (WinKARIN, WinKARIN Remote Control, Remote Control Interface) is absolutely necessary before going any further! Having obtained WinKARIN on floppy disk, make backup copies. Store the original disks in a safe place. Use the backup copies for the installation. Windows 3.X 1. Start Windows 3.X. 2. Start "Setup.exe" from Disk 1 or start "setup.exe" in the sub-directory "Disk 1" of the CD 3. Follow the instructions of the setup programme and select "WinKARIN" for installation. Windows After inserting the CD-ROM the setup programme starts automatically. 2. Follow the instructions of the program setup and select "WinKARIN" for installation. Start Requirements Before starting the monitoring program, please check the RS 232 interface connection. Start of the monitoring program Start the monitoring program by a double-click on the "WinKARIN" icon. When starting the monitoring program, a distinction has to be made between the following variants: z The PC is connected with the data modem (rack configuration). z The PC is connected with the compact power supply (main frame configuration). 2-4 WinKARIN 3.X ü

15 Installation Monitoring with data modem (rack configuration) After the start you can see the message "GET CONFIGURATION". This indicates that the communication with the data modem is correct. After some time (max. 10 min.) the message "GET CONFIGURATION" disappears and the mechanical design of the system is displayed (display mode "Headend"). The program is working in the Listener mode. Monitoring without data modem (main frame configuration) In the monitor you can see the message "NO COMMUNICATION". After approx. 10 seconds the menu item "Master" can be selected (bold type). Click the menu item "Master". After a few seconds the message "NO COMMUNICATI- ON" disappears and the mechanical composition of the system is displayed. (display mode "Headend"). For the main frame configuration the monitoring mode "Listener" is not available. Configuration Preferences In the menu "File\Preferences" the following settings can be made for the monitoring program: z z z z Selection of a communication port Kind and extent of the error report Rack size definition Password change ATTENTION The monitoring program is delivered with the passwords "GGA1", "GGA2", "GGA3", "GGA4" and "GGA5". Change these passwords in order to prevent manipulations of unauthorized persons. Write down any new password for your record. If you have lost the password, please contact your customer service. Channel configuration Configurating the display mode "Channels" means that all modules that are involved in processing a particular channel, up and down converters among others, are assigned to a channel name (e.g. CNN). Such assignments are needed for working in the display mode "Channels". ü WinKARIN 3.X 2-5

16 Installation NOTE: If you configurate a channel, you should already be familiar with the monitoring program. If you are not, please consult the on-line help file and read the how-to-do unit about channel configuration first. 2-6 WinKARIN 3.X ü

17 Operation General Overall design WinKARIN is capable of generating three different views of the headend. The headend view is based on the mechanical design of the headend and leads the user from the rack level to the main frame level and the module level. The modules view focuses on module types installed in the headend and leads the user from the modules level to the module menu. The channels view highlights the associations between channels/programs on the one hand and modules participating in the processing of these channels on the other hand. All three views converge into the module menu that contains the front-panel and the block-diagram of the module with optional switching facilities and indicates various measuring values. HEADEND MODULES CHANNELS VIDEO PROCESSOR 01 RTL Rack 1 Rack 2... SAT RECEIVER SND2 - MODULATOR 02 PRO7 03 ORF1 Select Select Racks Module List Channels SAT-Proz. Select PAL-Mod. Select SAT RECEIVER TUNING VOLTAGE IF INPUT LEVEL... SAT- Rec. Select Subc.- Demod. Select... Main Frames List Of Values Modules IF INPUT LEVEL SAT- Rec. Subc.- Demod dBm -40dBm -55dBm -25dBm -40dBm -55dBm 1/ 8/ 1 1/ 8/ 3 Select Select Modules Show Values Module Menu Survey of the display modes Windows operations The handling of the program complies with Windows standards. If you are not familiar with basic Windows operations, please refer to the Windows manual. 3-2 WinKARIN 3.X ü

18 Operation Icons Editing fields Quite a number of functions are accessible via icons. The meaning of each icon is explained in the status line of WinKARIN. The number of icons and their outlook in the main menu area may vary according to the activated monitoring mode. One or more editing fields may be embedded in the block-diagrams that differ in function. The function of a particular editing field is signalled by a cursor transformation. In other words, the cursor changes its shape whenever you move the mouse-pointer over the editing field. level meter available for indication of measured values limit is settable for the measured value level meter is available, limit is settable and measured value is adjustable level meter is available and measured value is adjustable input/output dialog available for channel setting, frequency setting, text output (on-line help) a.o. Hotspots Occasionally hotspots like "Commands" or "Preferences" may appear in blockdiagrams; they serve, for example, to load commands and configuration files from and to modules. The commands and the contents of the configuration files are explained in module-specific help files, which can be invoked via the hotspot HELP in the module menu (in the block diagram itself). A single blockdiagram may contain several hotspots of the same type. Generally speaking, the following types of hotspots can be distinguished: File transfer Window: This window serves the function of editing and updating a configuration file. In order to edit the configuration file it must be loaded from the module with the DOWNLOAD function. After editing the file it can be uploaded with the UPLOAD function and replaces the original file in the module. The file can also be stored on the hard disk with the SAVE function and later on be loaded into the File Transfer Window with the LOAD function. The SAVE and LOAD functions primarily serve to set up identical KARIN headend systems in an easy way through the distribution of a configuration file. ü WinKARIN 3.X 3-3

19 Operation NOTE: After changing the configuration file make sure that the module has accepted the new settings. To do so, load the configuration file once again into the File Transfer Window (after uploading the file to the module) and see if the configuration file contains the required entries now. Info Download Window: In this window read-only information is downloaded from the module. This information is directly accessible after opening the Info Download Window and may relate to recorded transmission errors, for example. Moreover, commands (for the Command Transfer Window) and the contents of the configuration file (for the File Transfer Window) may be described in an Info Download Window. NOTE: After changing settings in a configuration file the display of information in the Info Download Window can be updated with the DOWNLOAD function in order to check whether the new settings have caused any signal errors. Command Transfer Window: After the input of a command this command can be sent to the module with the UPLOAD function. Numeric Input Window: In the Numeric input a numerical value can be entered, for example, a frequency. Signalling The button "Error" or "Limit" respectively has a coloured background. The color indicates the following monitoring states: z green The system works perfectly z red There are faults/limit exceedings in the system z yellow There are still faults/limit exceedings in the system, but the system operator has already inspected the menu "Active Errors" or "Active Limits". NOTE: In addition, racks, main frames and modules are marked red, when an error occurs. Moreover, any error can be indicated by an alarm signal (optionally). 3-4 WinKARIN 3.X ü

20 Operation Menu structure In the following the functions of the individual menus of WinKARIN are described from left to right in a general way. You will find details about how to handle the WinKARIN functions in the on-line help file. File Setup printer Preferences Exit Here you can select and configure the printer of your choice. The procedure for doing this is identical with the one for other Windows applications. After installing WinKARIN you should check the presettings of the password, the communication port, the protocol output devices, the rack size and the time synchronisation of the PCs in the headend. Click EXIT to leave WinKARIN. ü WinKARIN 3.X 3-5

21 Operation View Headend Modules Channels Active errors Active limits Active differences History Limitsettings Module data Relative In the HEADEND view WinKARIN creates an image of the mechanical design of the headend and presents the headend as abstract images of racks, main frames, modules and block-diagrams. You can descend step-by-step to the module menu, which shows the module front-panel and the block-diagram. At the same time it presents the measured values on a numerical or level-meter display. In the MODULES view the headend is represented as a list of module types and values the user can choose from. You can descend from the module types level to the measured value indication and the module menu with the blockdiagram (see above). In the CHANNEL view WinKARIN gives the user access to channel information via lined-up module front-panels representing the modules accociated with a particular channel. WinKARIN keeps track of all the errors that have occured in the headend so far and collects them in a table together with information about the module and the channel concerned. You can view the list and print it out. WinKARIN records all limit exceedings that have occured in the headend so far in a table together with additional information about the module and channel concerned. You can view the list and print it out. WinKARIN collects information about non-default switch-overs of modules triggered by the user in a table together with additional information about the module and the channel concerned. WinKARIN writes all extra-ordinary events (errors, changes of switches, addition of modules) in a table, which is called history. You can print out this list and keep it for service purposes. WinKARIN records all the limits set by the user in a table together with additional information about the module and channel concerned. You can view this list, but you cannot print it out. WinKARIN is able to read important module data ( number, serial number, repair state etc.) from the EPROM of KARIN 2 modules and display them on the screen. WinKARIN permits to save present measured values in KARIN2 modules for reference purposes. Relative indication of measuring values is based on these stored reference values (see "Definitions - Adjust values") 3-6 WinKARIN 3.X ü

22 Operation Mode Listener Master Extended Master In the LISTENER mode WinKARIN does not send any data to the headend. As a consequence, module switchings are impossible and measuring values only partly displayed. Moreover, the actualisation of data may take considerable time. A PC is always in the listener mode if a RF-modem is used without equipped reverse channel, which means that there is no bidirectional connection between the headend and the PC, or another PC has changed to the Master mode. WinKARIN controls the data stream from and to the headend. The data to be displayed are being continuously actualized. For the change of the PC to the Master mode a bidirectional connection with the headend is necessary, that is, the PC must be connected to the data modem or the main frame powersupply. When connecting the PC to the RF-modem the reverse channel must be available. In the MASTER MODE module switchings are impossible and only a part of the measuring values displayed. In the EXTENDED MASTER MODE all information is available and module switchings are possible. ATTENTION: Leave the Extended master mode, when you have made switchovers in order to avoid unauthorised switchings. ü WinKARIN 3.X 3-7

23 Operation Tools Default Read headend Print Select headend WinKARIN enables you to define defaults of your own, if and only if you have a KARIN 2 headend (see KARIN2 specifications). This option sets module switches to their default positions. Running WinKARIN you can add modules any time you want. After adding modules to your headend and thus changing the configuration, you can tell WinKA- RIN to read in the new configuration immediately (otherwise there might be some delay in updating the headend information). Important information about modules and the channel configuration of your station can be printed out from anywhere you are in WinKARIN. All system-specific data (e.g. channel configuration, labels and notes) of a particular headend(s) can be stored in a configuration file in order to monitor and control several different headends with WinKARIN. 3-8 WinKARIN 3.X ü

24 Operation Definitions Labels, notes and marks Channels Limits Default Adjust values Reset adjust. values In WinKARIN objects (racks, main frames and modules) are assigned labels, marks and notes to facilitate recognition. While labels and marks ("identifiers") are directly displayed on the objects, notes are displayed in the lower status line. The user can adapt this kind of information to his needs and assign identifiers and notes of his choice to objects of the headend. In WinKARIN you can assign modules to operating channels (programs). This implies that you have to tell WinKARIN, which devices are involved in the processing of a particular channel. In WinKARIN various limits and the interval at which the measured value should be recorded can be set. This supports error detection and problem solving. If a limit is exceeded, an alarm is triggered (acoustic and / or visual) and the alarm is recorded in the history for review purposes. WinKARIN enables you to define defaults of your own, if and only if you have a KARIN 2 headend. WinKARIN permits to save present measured values in KARIN2 modules as reference values for the relative indication of measured values. Deletes the stored reference values. ü WinKARIN 3.X 3-9

25 Operation Help Messages How to do Help on help About Debug Click,,Messages" to obtain a list of messages generated by WinKARIN to guide the user and inform him about errors in the monitoring system and/or the headend. Click,,How to do" to get a hands-on introduction to the various functions of the monitoring program. Each function is explained in a how-to-do unit and occasionally illustrated by a real-to-life example. General information about how to use Windows help files Copyright notice and version number for the online help file Special function for service staff. ATTENTION: The DEBUG function is reserved for service purposes. Unauthorised use of this function may cause serious problems WinKARIN 3.X ü

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ Products: AMIQ, SMIQ AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ The software AMIQ-K2 enables you to read, convert, and transfer various-format I/Q data files to AMIQ format. AMIQ-K2

More information

Supplement to the Operating Instructions. PRemote V 1.2.x. Dallmeier electronic GmbH. DK GB / Rev /

Supplement to the Operating Instructions. PRemote V 1.2.x. Dallmeier electronic GmbH. DK GB / Rev / Supplement to the Operating Instructions PRemote V 1.2.x 1 DK 180.000.000 GB / Rev. 1.2.3 / 030416 PRemote V 1.2.x Copyright All rights reserved. This document may not be copied, photocopied, reproduced,

More information

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO ALARM VERIFICATION UNIT VIVER VIDEO ALARM VERIFICATION UNIT VIVER viver_en 09/08 The VIVER module provides remote video alarm verification, based on image sequences transmitted from cameras installed in the protected facility. The

More information

OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE

OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE AMENDMENT RECORD AMENDMENT NO. INCORP. BY DATE PAGE(S) VERSION CHANGE NOTE ( EM) 1 ES 06.10.2004 29 A 2 ES 04.03.2005 29 B Included

More information

DVB-T Box, USB Monheim/Germany Tel. +49 (0)9091/ Fax +49 (0)9091/ Hama GmbH & Co KG.

DVB-T Box, USB Monheim/Germany Tel. +49 (0)9091/ Fax +49 (0)9091/ Hama GmbH & Co KG. www.hama.de Hama GmbH & Co KG Postfach 80 86651 Monheim/Germany Tel. +49 (0)9091/502-0 Fax +49 (0)9091/502-274 hama@hama.de www.hama.de 00062776-01.05 DVB-T Box, USB 2.0 00062776 L TV USB receiver User

More information

Yellow Frog. Manual Version 1.1

Yellow Frog. Manual Version 1.1 Yellow Frog Manual Version 1.1 1 YellowFrog Contents PC Requirements...... 2 YellowFrog Power Meter Measurement.... 3 YellowFrog PC Software..... 3 Main Screen....... 4 Input Overload....... 5 Battery

More information

Instruction Manual DV5000 AV/ Component Bi-Directional DV- Video to Analog Converter

Instruction Manual DV5000 AV/ Component Bi-Directional DV- Video to Analog Converter Instruction Manual DV5000 AV/ Component Bi-Directional DV- Video to Analog Converter DV-5000 BI-DIRECTIONAL PROFESSIONAL DV-ANALOG MEDIA CONVERTER 2 Table Of Contents 1.0 Introduction 4 2.0 Specifications

More information

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM ATTENTION: READ THE ENTIRE INSTRUCTION SHEET BEFORE STARTING THE INSTALLATION PROCESS. WARNING! Do not begin to install your

More information

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130 User manual Transmodulators Ref. 5103S/5103T/5103Q/5130 Contents 1 Introduction 2 1.1 The ProQuad range................................ 2 1.2 Modular system solution.............................. 4 1.3

More information

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

APM CALIBRATION PROCEDURE Rev. A June 3, 2015 APM CALIBRATION PROCEDURE Rev. A June 3, 2015 Calibration of the APM allows system parameters such as coupler coupling values, interconnecting cable losses and system feeder losses to be programmed into

More information

TransitHound Cellphone Detector User Manual Version 1.3

TransitHound Cellphone Detector User Manual Version 1.3 TransitHound Cellphone Detector User Manual Version 1.3 RF3 RF2 Table of Contents Introduction...3 PC Requirements...3 Unit Description...3 Electrical Interfaces...4 Interface Cable...5 USB to Serial Interface

More information

Manual 4.0. VIPdigital Manual 4.0 Yellowtec 2004 Rev Page 1

Manual 4.0. VIPdigital Manual 4.0 Yellowtec 2004 Rev Page 1 Manual 4.0 VIPdigital Manual 4.0 Yellowtec 2004 Rev. 26.07.2004 Page 1 TABLE OF CONTENTS 1 BRIEF DESCRIPTION... 6 2 PRIOR TO BEGINNING... 7 2.1 CONVENTIONS USED IN THE MANUAL... 7 2.1.1 Using the screen...

More information

HyperMedia User Manual

HyperMedia User Manual HyperMedia User Manual Contents V3.5 Chapter 1 : HyperMedia Software Functions... 3 1.1 HyperMedia Introduction... 3 1.2 Main Panel... 3 1.2.2 Information Window... 4 1.2.3 Keypad... 4 1.2.4 Channel Index...

More information

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY 493456301 Rev B April 2009 Table of Contents Installation... 1 Setup... 2 Operation... 4 Live Video... 4 Video Settings... 5 Network

More information

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Written By: Colin Langridge Issue: Draft Date: 03 rd July 2008 1 Date: 29 th July 2008 2 Date: 20 th August 2008 3 Date: 02 nd

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents FOUR CHANNEL USB RECORDER PCRU01 User manual Table of Contents Features 2 Specifications 2 hardware 2 software: 2 system requirements 2 Software installation 2 SAFETY and WARNINGS 3 Warranty 3 Connections

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface O P E R A T I O N M A N U A L Version 01/05 RF-Reader Stand-alone-Reader Leser 2plus with RS-232 interface Important! Read by all means! To maintain the perfect shipping conditions and to ensure safe operation

More information

DVB-T USB SET-TOP BOX

DVB-T USB SET-TOP BOX DVB-T USB SET-TOP BOX User Manual Version: 1.0 (February 2005) TRANSYSTEM INC. No.1-2 Li-Hsin Rd.I Science-Based Industrial Park, Hsinchu, Taiwan Tel:+886-3-5780393 Fax:+886-3-5784111 e-mail: sales@transystem.com.tw

More information

Supplements to the FSP Operating Manual TV-Demodulator

Supplements to the FSP Operating Manual TV-Demodulator Test and Measurement Division Supplements to the FSP Operating Manual TV-Demodulator FSP-B6 1129.8642.02 Dear FSP Customer, The following collection of pages is intended to supplement your FSP operating

More information

Cablecast SX. Setup Guide. c Tightrope Media Systems For Cablecast version Build 206

Cablecast SX. Setup Guide. c Tightrope Media Systems For Cablecast version Build 206 Cablecast SX Setup Guide c Tightrope Media Systems For Cablecast version 5.2.11 Build 206 Printed June 5, 2015 1 Cablecast SX Setup 1.1 Prerequisites 1.2 Overview of Setup Thank you for purchasing a Cablecast

More information

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica AVE HOME CVBS TO DVB-T ENCODER MODULATOR FAGOR Fagor Electr6nica TABLE OF CONTENTS 1. SPECIFICATIONS... 12 1.1 Product Overview... 12 1.2 Appearance and Description... 12 1.3 Diagram... 13 1.4 Characteristics...

More information

FlyTV Express M5 MST-T 2 A 2

FlyTV Express M5 MST-T 2 A 2 FlyTV Express M5 MST-T 2 A 2 User Manual Animation Technologies Inc. www.lifeview.com Ver: 1.0 Copyright and Trademark Notice 2006 by Animation Technologies Inc. All rights reserved. Information in this

More information

MSP 200PRO Quick Start

MSP 200PRO Quick Start MSP 200PRO Quick Start Touch Screen control Output a range of signal types Set and select from a range of common output formats Audio output test included Genlock Y&HS outputs Input live signals for preview

More information

USER GUIDE FOR NETmc MARINE X-Ops

USER GUIDE FOR NETmc MARINE X-Ops USER GUIDE FOR NETmc MARINE X-Ops Rev.2.2 Firmware v.1.2.8 X-Ops, 1.2.9 Pipeline September 2013 NETmc Marine X-Ops Manual-Rev.2.2 September 2013 1 of 17 Contents 1. Introduction... 3 1.1 Multi-channel

More information

Network Camera Operating Manual

Network Camera Operating Manual Network Camera Operating Manual Model No. WV-NW484S Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. Preface About these

More information

A-ATF (1) PictureGear Pocket. Operating Instructions Version 2.0

A-ATF (1) PictureGear Pocket. Operating Instructions Version 2.0 A-ATF-200-11(1) PictureGear Pocket Operating Instructions Version 2.0 Introduction PictureGear Pocket What is PictureGear Pocket? What is PictureGear Pocket? PictureGear Pocket is a picture album application

More information

MaxView Cinema Kit Quick Install Guide

MaxView Cinema Kit Quick Install Guide SYSTEM SETUP The MaxView will work at any of the following display settings: INSTALLATION MaxView Cinema Kit Quick Install Guide Step 1 - Turn off your computer. Disconnect your monitor s VGA cable from

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

Network Disk Recorder WJ-ND200

Network Disk Recorder WJ-ND200 Network Disk Recorder WJ-ND200 Network Disk Recorder Operating Instructions Model No. WJ-ND200 ERROR MIRROR TIMER HDD1 REC LINK /ACT OPERATE HDD2 ALARM SUSPEND ALARM BUZZER STOP Before attempting to connect

More information

F24X DSK Setup and Tutorial

F24X DSK Setup and Tutorial F24X DSK Setup and Tutorial 1999 DSP Development Systems F24X DSK Setup and Tutorial 504706-0001 Rev. A July 1999 SPECTRUM DIGITAL, INC. 10853 Rockley Road Houston, TX. 77099 Tel: 281.561.6952 Fax: 281.561.6037

More information

SHENZHEN H&Y TECHNOLOGY CO., LTD

SHENZHEN H&Y TECHNOLOGY CO., LTD Chapter I Model801, Model802 Functions and Features 1. Completely Compatible with the Seventh Generation Control System The eighth generation is developed based on the seventh. Compared with the seventh,

More information

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference. 4-743-161-12 (1) Wireless Studio User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference. DWR-R01D/R02D/R02DN/R03D 2018 Sony Corporation

More information

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER AC334A BLACK BOX 724-746-5500 VGA-Video Ultimate BLACK BOX 724-746-5500 Zoom Position PAL ZOOM/FREEZE POWER FREEZE ZOOM NTSC/PAL SIZE RESET POWER Size Power Remote Control DC IN MOUSE MIC IN AUDIO OUT

More information

Broadcast Television Measurements

Broadcast Television Measurements Broadcast Television Measurements Data Sheet Broadcast Transmitter Testing with the Agilent 85724A and 8590E-Series Spectrum Analyzers RF and Video Measurements... at the Touch of a Button Installing,

More information

Manual Version Ver 1.0

Manual Version Ver 1.0 The BG-3 & The BG-7 Multiple Test Pattern Generator with Field Programmable ID Option Manual Version Ver 1.0 BURST ELECTRONICS INC CORRALES, NM 87048 USA (505) 898-1455 VOICE (505) 890-8926 Tech Support

More information

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY AC335A BLACK BOX 724-746-5500 VGA-Video Ultimate Plus Position OVERLAY MIX POWER FREEZE ZOOM NTSC/PAL SIZE GENLOCK POWER DC IN MOUSE MIC IN AUDIO OUT VGA IN/OUT (MAC) Remote Control Back Panel View RGB

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A)

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 66 Module This document has been written by Siemens AG for training

More information

Dragon. manual version 1.6

Dragon. manual version 1.6 Dragon manual version 1.6 Contents DRAGON TOP PANEL... 2 DRAGON STARTUP... 2 DRAGON STARTUP SCREEN... 2 DRAGON INFO SCREEN... 3 DRAGON MAIN SCREEN... 3 TURNING ON A TRANSMITTER... 4 CHANGING MAIN SCREEN

More information

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00 Re:source Communication Module SAT Version Dominating Entertainment. Revox of Switzerland. E2.00 Please note: Software update! Unlike the software for the Standard communication module, the SAT control

More information

Operation and Installation Guide

Operation and Installation Guide Operation and Installation Guide HDS2800 Series Encoder Modulator High Definition (HD) Digital COFDM MPEG2 and H.264 Modulator with IP Multicast. 19 Rack Mount Revision 4.0 Firmware version Released File

More information

RF Detector with Real Time remote Monitoring Capability Protect from RF Audio/Video Transmitters and Laser Monitoring System USER MANUAL rev.

RF Detector with Real Time remote Monitoring Capability Protect from RF Audio/Video Transmitters and Laser Monitoring System USER MANUAL rev. DX RF Detector with Real Time remote Monitoring Capability Protect from RF Audio/Video Transmitters and Laser Monitoring System USER MANUAL rev.2 1 Global TSCM Group, Inc. 2 Devine Avenue, Syosset 11791,

More information

Cisco Spectrum Expert Software Overview

Cisco Spectrum Expert Software Overview CHAPTER 5 If your computer has an 802.11 interface, it should be enabled in order to detect Wi-Fi devices. If you are connected to an AP or ad-hoc network through the 802.11 interface, you will occasionally

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MATRIX SYSTEM SX-2000 SERIES Thank you for purchasing TOA's Matrix System. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

More information

FlexCabling. Hemmaprodukter. Tillbehör. Kontorsprodukter. Övrigt

FlexCabling. Hemmaprodukter. Tillbehör. Kontorsprodukter. Övrigt FlexCabling Hemmaprodukter Skåp 4U Skåp 6U Skåp 9U x 12 (Cat 5E) Management Panel TV/Radio Splitter 1 4 TV/Radio Splitter 1 8 TV- och radiokabel Telefonsplitter Ethernets-switch (Gigabit) Tillbehör AV

More information

AVTuner PVR Quick Installation Guide

AVTuner PVR Quick Installation Guide AVTuner PVR Quick Installation Guide Introducing the AVTuner PVR The AVTuner PVR allows you to watch, record, pause live TV and capture high resolution video on your computer. Features and Benefits Up

More information

Projector Management Application Version 7.00 Instruction Guide

Projector Management Application Version 7.00 Instruction Guide Projector Management Application Version 7.00 Instruction Guide Contents 1 INTRODUCTION... 4 1.1 OUTLINE... 4 1.2 SYSTEM... 4 2 INSTALLATION... 5 2.1 SYSTEM REQUIREMENTS... 5 2.2 PROJECTOR MANAGEMENT APPLICATION

More information

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03 of of M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03 Attention Software Update After updating the M203 firmware to version 2.00 or higher, we recommend completely resetting

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

of Loewe E 2.10_m1 1

of Loewe E 2.10_m1 1 of Loewe E 2.10_m1 1 Attention! After updating the M203 firmware to version 2.00 or higher, we recommend completely resetting the M203 interface by pressing the Disable softkey on setup page #2 for several

More information

C Module Description

C Module Description IQMMX -Input Router & ASI Distribution Amplifier C Module Description The IQMMX is an ASI to 1 switch, distribution amplifier and transport stream switcher with up to 8 outputs in double width form or

More information

DVR-431 USB Wireless Receiver User Manual

DVR-431 USB Wireless Receiver User Manual DVR-431 USB Wireless Receiver User Manual Thank you for using our wireless USB receiver, please read the following content carefully before using, it will help you make better use of this product. Introduction

More information

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is

More information

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications. Application Note DTV Exciter Model Number: Xtreme-1000E Version: 4.0 Date: Sept 27, 2007 Introduction This application note describes the XTREME-1000E Digital Exciter and its applications. Product Description

More information

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5 Video Video Series Series Video Tracking System 8.2 HCS-4311M Professional Mixed Matrix for Conference 8.2 HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5 HCS-3313D High Quality Speed Dome Camera

More information

The Art of Engineering

The Art of Engineering The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet

More information

MLW-2 Operating Manual

MLW-2 Operating Manual MLW-2 Operating Manual MLW-2 Operating Manual Introduction The Titus Technological Laboratories MLW-2 was inspired by years of products like the MLW-1, MLW-4, MLW-8, and The Last Word (I and II). The features

More information

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual ZyCastR digi-mod HD Range digi-mod HD-1603 www.digi-modbyzycast.com HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual Table of Contents www.digi-modbyzycast.com Safety

More information

User s Guide W-E

User s Guide W-E Presto! PVR ISDB User s Guide 518100-02-01-W-E-112307-02 Copyright 2007, NewSoft Technology Corp. All Rights Reserved. No portion of this document may be copied or reproduced in any manner without prior

More information

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher Kramer Electronics, Ltd. USER MANUAL Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview

More information

D-901 PC SOFTWARE Version 3

D-901 PC SOFTWARE Version 3 INSTRUCTION MANUAL D-901 PC SOFTWARE Version 3 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

Using SignalTap II in the Quartus II Software

Using SignalTap II in the Quartus II Software White Paper Using SignalTap II in the Quartus II Software Introduction The SignalTap II embedded logic analyzer, available exclusively in the Altera Quartus II software version 2.1, helps reduce verification

More information

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending DVISm Patent Pending DVISm - Mini Digital Video Insertion System Quick Start Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make

More information

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9 Light-Switch & Switch-Edit Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9 Artistic Licence Engineering Ltd. Switch-Edit Manual 2/47 Artistic Licence Engineering Ltd. Switch-Edit

More information

DX-10 tm Digital Interface User s Guide

DX-10 tm Digital Interface User s Guide DX-10 tm Digital Interface User s Guide GPIO Communications Revision B Copyright Component Engineering, All Rights Reserved Table of Contents Foreword... 2 Introduction... 3 What s in the Box... 3 What

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S INSTRUCTIONS FOR USE Pro-Ject Tuner Box S Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s 120531 M5-H002 Multiview T-35 DVB-T to PAL / 5 channels on all TV s Contents Multiview... 3 Features... 3 Caution... 3 Front & Rear Panel... 4 Connecting... 5 Programming... 6 Information... 7 Installation...8

More information

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/ 11/6/2009 www.elber.com elber@elber.it TCU/RCU RF Head Control Units User Manual Elber s.r.l.- Via Pontevecchio, 42W Phone +39-0185.35.13.33 16042 Carasco (GE) Italy Fax +39-0185.35.13.00 1 Sommario 2

More information

Coax A/V Agile Demodulator Tuner W/IR Remote Control. User Manual (Model: RFDM2 PDK)

Coax A/V Agile Demodulator Tuner W/IR Remote Control. User Manual (Model: RFDM2 PDK) Coax A/V Agile Demodulator Tuner W/IR Remote Control User Manual (Model: RFDM2 PDK) 1. Product Features: RFDM2-PDK Demodulator with IR Remote This coax to composite A/V demodulator is a professional grade

More information

DVI KVM Extender DVIVision 7.6

DVI KVM Extender DVIVision 7.6 DVIVision 7.6 KVM Extender Extender systems to bridge IT-distances Leading the way in digital KVM The company Leading the way in digital KVM Guntermann & Drunck is regarded as a leading manufacturer of

More information

TECHNICAL MANUAL. Cheetah VIDEO MATRIX ROUTERS 3G VIDEO INPUT CARD WITH AUDIO DE-EMBEDDING AND 3G VIDEO OUTPUT CARD WITH AUDIO EMBEDDING

TECHNICAL MANUAL. Cheetah VIDEO MATRIX ROUTERS 3G VIDEO INPUT CARD WITH AUDIO DE-EMBEDDING AND 3G VIDEO OUTPUT CARD WITH AUDIO EMBEDDING TECHNICAL MANUAL Cheetah VIDEO MATRIX ROUTERS 3G VIDEO INPUT CARD WITH AUDIO DE-EMBEDDING AND 3G VIDEO OUTPUT CARD WITH AUDIO EMBEDDING Publication: 81-9059-0658-0, Rev. A August, 2009 Thank You!! for

More information

HDMI-8x8. MicroQ User Manual APANTAC LLC, 7556 SW BRIDGEPORT ROAD, PORTLAND, OR TEL: , FAX:

HDMI-8x8. MicroQ User Manual APANTAC LLC, 7556 SW BRIDGEPORT ROAD, PORTLAND, OR TEL: , FAX: HDMI-8x8 MicroQ User Manual COPYRIGHT and TRADEMARK All rights reserved by APANTA LCC, Porland, Oregon, USA. No part of this document may be reproduced in any form or by any means without written permission

More information

3G/HD/SD dual channel audio embedder/de-embedder

3G/HD/SD dual channel audio embedder/de-embedder 3G/ dual channel audio embedder/de-embedder Dual channel audio embedder/de-embedder, with two independent video channels Being dual channel makes the audio embedder/de-embedder perfect for those pricesensitive

More information

Part 1 Basic Operation

Part 1 Basic Operation This product is a designed for video surveillance video encode and record, it include H.264 video Compression, large HDD storage, network, embedded Linux operate system and other advanced electronic technology,

More information

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2 Dear music lover, thank you for purchasing a Pro-Ject Audio Systems FM-tuner. In order to achieve maximum performance and reliability you should study these instructions

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

User Manual. June 30, Copyright 2004 Canopus Co., Ltd. All rights reserved.

User Manual. June 30, Copyright 2004 Canopus Co., Ltd. All rights reserved. User Manual June 30, 2004 Copyright 2004 Canopus Co., Ltd. All rights reserved. Notices & Warraties Copyright Regulations It is illegal for anyone to violate any of the rights provided by the copyright

More information

CYBERMIX Operating Manual

CYBERMIX Operating Manual CYBERMIX Operating Manual 32 Channel Mixer Automation English Version 1.0 August 1996 The information contained in this manual is subject to change without notice. No part of this manual may be reproduced

More information

Matrix Switcher. Users Guide ANI-VGA ANI-V ANI-RGB

Matrix Switcher. Users Guide ANI-VGA ANI-V ANI-RGB Matrix Switcher Users Guide ANI-VGA ANI-V ANI-RGB Document version: 052012 For use of the device and safety of users, please follow the instructions when installing, using and maintaining: The system must

More information

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00 of M203 LG D 2.06 Attention! After updating the M203 firmware to version 2.00 or higher, we recommend completely resetting the M203 interface by pressing the Disable softkey on setup page #2 for several

More information

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR INSTRUCTION MANUAL Features of the new DVB-C transmodulators line Through the use of the FPGA technology the transmodulators provides the highest performance at the lowest price. Four carriers are formed

More information

Intelligent Security and Fire Ltd

Intelligent Security and Fire Ltd User Manual Product ranges covered by this manual Vi-P14 Vi-P14A Document Reference Date Firmware Vi-Q4C1 Viq601a.doc 26/11/2009 From Viq001a21 Videoswitch Telephone 01252-851510 Ocean House, Redfields

More information

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015 TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V1.2-1.4 January 2015 A display and command module for the Trimble Thunderbolt GPS with 10MHz reference oscillator. by Hubbatech Software Revision Notes: 1.2-2014

More information

Teletext Inserter Firmware. User s Manual. Contents

Teletext Inserter Firmware. User s Manual. Contents Teletext Inserter Firmware User s Manual Contents 0 Definition 3 1 Frontpanel 3 1.1 Status Screen.............. 3 1.2 Configuration Menu........... 4 2 Controlling the Teletext Inserter via RS232 4 2.1

More information

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents F. S. BRAINARD & COMPANY PO Box 366, 5 Terri Lane Unit 15, Burlington, NJ 08016 tel: (609) 387-4300 fax: (609) 387-4304 www.meter-master.com email: cellosupport@meter-master.com CELLO SETUP WITH WinGPS

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03 of Re:connect M 203 RS232 Interface Revox Dominating Entertainment. Revox of Switzerland. E 2.03 Attention! After updating the firmware to version 2.00 or higher, we recommend completely resetting the

More information

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 Triarchy Technologies Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013 Triarchy Technologies,

More information

Scan Converter Installation Guide

Scan Converter Installation Guide Scan Converter Installation Guide Software on supplied disks Please note: The software included with your scan converter is OPTIONAL. It is not needed to make the scan converter work properly. This software

More information

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

User Guide & Reference Manual

User Guide & Reference Manual TSA3300 TELEPHONE SIGNAL ANALYZER User Guide & Reference Manual Release 2.1 June 2000 Copyright 2000 by Advent Instruments Inc. TSA3300 TELEPHONE SIGNAL ANALYZER ii Overview SECTION 1 INSTALLATION & SETUP

More information

Training Note TR-06RD. Schedules. Schedule types

Training Note TR-06RD. Schedules. Schedule types Schedules General operation of the DT80 data loggers centres on scheduling. Schedules determine when various processes are to occur, and can be triggered by the real time clock, by digital or counter events,

More information

VIDEO GRABBER. DisplayPort. User Manual

VIDEO GRABBER. DisplayPort. User Manual VIDEO GRABBER DisplayPort User Manual Version Date Description Author 1.0 2016.03.02 New document MM 1.1 2016.11.02 Revised to match 1.5 device firmware version MM 1.2 2019.11.28 Drawings changes MM 2

More information

feno before light and beyond

feno before light and beyond User Manual Multi 4 Control Version 2.0 feno GmbH, Kolpingring 22, 82041 Oberhaching, Germany P +49 89 613725 30, F +49 89 613725 50 email@feno.com, www.feno.com This manual and the associated software

More information

Tektronix RSA306 USB Spectrum Analyzer

Tektronix RSA306 USB Spectrum Analyzer Tektronix RSA306 USB Spectrum Analyzer Simple Demos The Demo of the RSA306 is easy. Even you do not have signal generators, devices under test, or demo boards, using the whip antenna provided in box, you

More information

N+1 Redundancy with the VCom HD4040 Upconverter

N+1 Redundancy with the VCom HD4040 Upconverter N+1 Redundancy with the VCom HD4040 Upconverter Document ID: 47164 Contents Introduction Prerequisites Requirements Components Used Conventions Set Up Communication with the Upconverter VCom Dual4040D

More information

Xsarius Satmeter Pro. Manual

Xsarius Satmeter Pro. Manual Xsarius Satmeter Pro Manual 1 2 Directory of content Introduction Directory of content 3 Introduction 3 Satmeter Pro 02 Frontpanel & buttons 6 Xsarius provides high quality products that enable you to

More information

CMS MANUAL DIGITAL VIDEO RECORDER CMS. Operation Manual 3CTC-016-5EN8M. For the safe use of the product, please make sure to read Safety Precautions.

CMS MANUAL DIGITAL VIDEO RECORDER CMS. Operation Manual 3CTC-016-5EN8M. For the safe use of the product, please make sure to read Safety Precautions. DIGITAL VIDEO RECORDER CMS Operation Manual 3CTC-016-5EN8M For the safe use of the product, please make sure to read Safety Precautions. 1 Copyrights All the contents of this manual are protected under

More information