HOW TO COMPOSE THE ORDERING REFERENCES MALE CONNECTORS PREASSEMBLED ON SENSORS

Size: px
Start display at page:

Download "HOW TO COMPOSE THE ORDERING REFERENCES MALE CONNECTORS PREASSEMBLED ON SENSORS"

Transcription

1 MALE CONNECTORS PREASSEMBLED ON SENSORS General informations: This section presents sensors already cabled to male connectors for particular applications. Specific cable lengths are available upon request on all the products. BDC versions with rotating nut allow the direct connection to the connection boxes reducing the costs and improving the reliability of the plant. Other solutions with different products are possible according to customer specification. The suggested connectors have to be matched to the sensors according to the cable sections, indicated on the ordering references tables inside the catalogue. HOW TO COMPOSE THE Type DCA / H 0 9 KSGD 0, lenght (m) Type Dimensions Manufacturer Series Degree of protection Suitable for cables diameter (mm) H Ø, M x 0 8 SW Ø 0, BDC M x rotating nut IP68 Note: more detailed technical data are available on specific manufacturers data sheets. BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com F

2 HOW TO INTERPRETE THE CONNECTORS MOULDED WITH CABLE N Connector: 8B = right angled female M x for d.c. sensors 9 = straight male M x for d.c. sensors 9B = right angled male M x for d.c. sensors 0 = straight female M x for d.c. sensors C 0 / 0 0 PV A N conductors: = wires = wires = wires = wires length m. = m. = m. 0 = 0 m. material: PV = ( for GD; grey for GD) PR = ( for GD; for GD) T = Thermoplastic grey rubber (0 0 C) Atex Versions: A = Category GD GD = Category GD Note: When using female connectors, please consider an insertion length inside the sensor, which is: M connectors = 8 mm I.E. Sensor DCA8/09KSGD total length = 60 mm Connector C8B/00PVGD total length = 9 mm Overall dimension sensor connector = (60 9) 8 = 8 mm. BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com G

3 FEMALE CONNECTORS M x For ATEX sensors Degree of protection IP68 Straight in d.c. Moulded with cable According to 9/9/CE EN EN 6097 Connector 0A Ø, M x SW Ø 0, General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The wire model is suitable for NAMUR sensors either on N.O. or N.C. version. It is possible to use it in zone 0 or 0 without additional protection against electrostatic charges. Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Operating voltage: max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) selflocking in CuZn, nickel plated brass Temperature range for and versions: 90 C for HT versions: 0 0 C Degree of protection: IP68 with plug in fully locked position * = HT, thermoplastic rubber 0 0 C Category G D G D G D Zone 0 0 Connector n Cap. cable pf/m Indutt. cable μh/m , 0,8 0,8 wires () wires (grey) wires (grey) x 0,7 mm ø ext. x 0,0 mm ø ext. x 0, mm ø ext. NO 0A 0A 0A 0A 0A 0A 0A 0A 0A C0/00PVA C0/00PVA C0/000PVA C0/00PRA C0/00PRA C0/000PRA C0/00PVGD C0/00PVGD C0/000PVGD C0/00PRGD C0/00PRGD C0/000PRGD C0/00TGD C0/00TGD C0/000TGD C0/00PVGD C0/00PVGD C0/000PVGD C0/00PRGD C0/00PRGD C0/000PRGD C0/00TGD C0/00TGD C0/000TGD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com G

4 FEMALE CONNECTORS M x For ATEX sensors Right angled in d.c. Degree of protection IP68 Moulded with cable According to 9/9/CE EN EN6097 Connector 9 SW Ø, M x 7, 7 8, Ø 0, General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The wire model is suitable for NAMUR sensors either on N.O. or N.C. version. It is possible to use it in zone or without additional protection against electrostatic charges. Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Operating voltage: max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) selflocking in CuZn, nickel plated brass Temperature range for and versions: 90 C For HT versions: 0 0 C Degree of protection: IP68 with plug in fully locked position * = HT, thermoplastic 0 0 C Category G D G D G D Connector n Zone Cap. cable pf/m Indutt. cable μh/m , 0,8 0,8 wires () wires (grey) wires (grey) x 0,7 mm ø ext. x 0,0 mm ø ext. x 0, mm ø ext. NO G C8B/00PVA C8B/00PVA C8B/000PVA C8B/00PRA C8B/00PRA C8B/000PRA C8B/00PVGD C8B/00PVGD C8B/000PVGD C8B/00PRGD C8B/00PRGD C8B/000PRGD C8B/00TGD C8B/00TGD C8B/000TGD C8B/00PVGD C8B/00PVGD C8B/000PVGD C8B/00PRGD C8B/00PRGD C8B/000PRGD C8B/00TGD C8B/00TGD C8B/000TGD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com

5 MALE CONNECTORS M x For ATEX applications Straight in d.c. Moulded with cable According to 9/9/CE EN EN 6097 Connector Ø, M x 0 8 SW Ø 0, General features: Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Operating voltage: max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) selflocking in CuZn, nickel plated brass Temperature range: 90 C Degree of protection: IP68 with plug in fully locked position Category G D G D Zone Connector n Cap. cable pf/m Indutt. cable μh/m ,8 0,8 wires (grey) wires (grey) x 0,0 mm ø ext. x 0, mm ø ext. NO 0 0 C9/00PVGD C9/00PVGD C9/000PVGD C9/00PRGD C9/00PRGD C9/000PRGD C9/00PVGD C9/00PVGD C9/000PVGD C9/00PRGD C9/00PRGD C9/000PRGD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com G

6 MALE CONNECTORS M x For ATEX applications Right angled in d.c. Degree of protection IP68 Moulded with cable According to 9/9/CE EN EN6097 Connector SW Ø, 8 M x SW 7 8, Ø 0, General features: Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Operating voltage: max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) selflocking in CuZn, nickel plated brass Temperature range: 90 C Degree of protection: IP68 with plug in fully locked position Category G D G D Zone Cap. cable pf/m Connector n Indutt. cable μh/m 0,8 0,8 wires (grey) wires (grey) x 0,0 mm ø ext. x 0, mm ø ext. NO 0 0 C9B/00PVGD C9B/00PVGD C9B/000PVGD C9B/00PRGD C9B/00PRGD C9B/000PRGD C9B/00PVGD C9B/00PVGD C9B/000PVGD C9B/00PRGD C9B/00PRGD C9B/000PRGD G6 BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com

7 HOW TO INTERPRETE THE MOULDED CONNECTING CABLES FOR ATEX SENSORS N Male connector: 9 = straight M x 9B = right angled M x N Female connector: 8B = right angled M x 0 = straight M x C9 / C0 / 00 0,6 PV A 00 = without LED N conductors: = wires = wires = wires length 0,6 = 0,6 m = m = m Other cable lengths upon request material: PV = PR = Category: A = GD or GD GD = GD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com H

8 MOULDED CONNECTING CABLES FOR ATEX SENSORS MALE M x straight FEMALE M x According to 9/E EN EN6097 C9/C0/ 0 8 Ø 0, Ø 0, Ø, Ø, M x SW SW M x wires version wires version wires version C9/C8B/ Ø, M x 0 8 SW Ø 0, Ø 0, M x Ø, 7, 7 8, 9 wires version wires version wires version Operating voltage max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) Moulding: selflocking in CuZn, nickel plated brass Temperature range: 90 C Degree of protection: IP68 with plug in fully locked position Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Category Zone Cap.cable pf/m Indutt. cable uh/m 0,6 0,6 G D 0 0 C9/C0/000,6PVA C9/C0/00PVA C9/C0/00PVA C9/C0/000,6PRA C9/C0/00PRA C9/C0/00PRA 0 0, wires () x 0,7 mm ø ext. G D C9/C8B/000,6PVA C9/C8B/00PVA C9/C8B/00PVA C9/C8B/000,6PRA C9/C8B/00PRA C9/C8B/00PRA C9/C0/000,6PVGD C9/C0/00PVGD C9/C0/00PVGD C9/C0/000,6PRGD C9/C0/00PRGD C9/C0/00PRGD G D ,8 0,8 wires (grey) C9/C8B/000,6PVGD C9/C8B/00PVGD C9/C8B/00PVGD C9/C8B/000,6PRGD C9/C8B/00PRGD C9/C8B/00PRGD C9/C0/000,6PVGD C9/C0/00PVGD C9/C0/00PVGD C9/C0/000,6PRGD C9/C0/00PRGD C9/C0/00PRGD G D wires (grey) x 0,0 mm ø ext. x 0, mm ø ext. NO C9/C8B/000,6PVGD C9/C8B/00PVGD C9/C8B/00PVGD C9/C8B/000,6PRGD C9/C8B/00PRGD C9/C8B/00PRGD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com H

9 MOULDED CONNECTING CABLES FOR ATEX SENSORS MALE M x right angled FEMALE M x According to 9/9/CE EN EN 6097 C9B/C0/ Ø, M x 8 SW 7 Ø 0, Ø 0, Ø, 8, SW M x wires version wires version wires version C9B/C8B/ Ø, M x SW 8 7 Ø 0, M x Ø, Ø 0, 7, 9 H Category Zone Cap.cable pf/m Indutt. cable uh/m 0,6 0,6 7 8, 8, C9B/C0/000,6PVA C9B/C0/00PVA C9B/C0/00PVA C9B/C0/000,6PRA C9B/C0/00PRA C9B/C0/00PRA wires version wires version wires version G D 0 0, wires () x 0,7 mm ø ext. C9B/C8B/000,6PVA C9B/C8B/00PVA C9B/C8B/00PVA C9B/C8B/000,6PRA C9B/C8B/00PRA C9B/C8B/00PRA C9B/C0/000,6PVGD C9B/C0/00PVGD C9B/C0/00PVGD C9B/C0/000,6PRGD C9B/C0/00PRGD C9B/C0/00PRGD Operating voltage max 0 Vac/7 Vdc A mω Contacts: CuZn, brass prenickeled and gold plated (0,8 μm) Moulding: selflocking in CuZn, nickel plated brass Temperature range: 90 C Degree of protection: IP68 with plug in fully locked position Note: use in hazardous area must be according to the instruction manual supplied together the sensors. G D ,8 0,8 wires (grey) C9B/C8B/000,6PVGD C9B/C8B/00PVGD C9B/C8B/00PVGD C9B/C8B/000,6PRGD C9B/C8B/00PRGD C9B/C8B/00PRGD C9B/C0/000,6PVGD C9B/C0/00PVGD C9B/C0/00PVGD C9B/C0/000,6PRGD C9B/C0/00PRGD C9B/C0/00PRGD C9B/C8B/000,6PVGD C9B/C8B/00PVGD C9B/C8B/00PVGD C9B/C8B/000,6PRGD C9B/C8B/00PRGD C9B/C8B/00PRGD BDC Electronic Viale Lidice, 7/9 009 Grugliasco (To) Italy Tel. (9)0..9.0/0 Fax (9) bdc@bdcelectronic.com G D wires (grey) x 0,0 mm ø ext. x 0, mm ø ext. NO

SERIES 400 SERIES 620

SERIES 400 SERIES 620 x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Size B INDUSTRIAL STANDARD

Size B INDUSTRIAL STANDARD Size B INDUSTRIA STANDARD Actuators series DIN EN 70-80 Industrial standard + ow housing Degree of protection IP6 Wired versions Moulded versions Degree of protection IP67 Female power connector Cable

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

TWINTEC B Signal Circular Connectors

TWINTEC B Signal Circular Connectors Signal Circular Connectors 67 Ordering information signal circular connectors ll standard connectors are published in this catalog. However, this catalog does not provide customer specific designs or

More information

Read/write head TN-M18-H1147

Read/write head TN-M18-H1147 Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS SERIES BNC 50, COAXIAL MINIATURE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER BNC is still one of the most popular connector series, featuring a two stud bayonet coupling mechanism, which is particularly

More information

Read/Write Head TN-M30-H1147

Read/Write Head TN-M30-H1147 Threaded barrel, M30 x 1.5 Chrome-plated brass /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030004 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating voltage 10 30

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/ Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Connecting cables for valve terminals, M9x0.5 Type codes

Connecting cables for valve terminals, M9x0.5 Type codes Type codes KVI CP 3 KVI Connecting cables for valve terminals Usage CP CPI interface Cable characteristic 3 Suitable for energy chains Connection technology on the left, field device side GS WS Straight

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

>Inductive and. REFERENCE guide. Capacitive Sensors

>Inductive and. REFERENCE guide. Capacitive Sensors >Inductive and REFEREE guide Capacitive Sensors DATALOGIC: SOLUTIONS FOR INDUSTRIAL AUTOMATION Datalogic Industrial Automation is an industry-leader in products and solutions for material handling, traceability,

More information

Connecting cables NEBS, for sensors

Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic

More information

Connecting cables for valves, round plug connectors Product range overview

Connecting cables for valves, round plug connectors Product range overview Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information M8 and M Sensor Connectors XS_-EU For a wide range of applications the XS_-EU family of M8 and M sensor connectors provides the high performance and features making the family the ideal choice for standard

More information

Panel-mounting Thermostats EM Series

Panel-mounting Thermostats EM Series Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

Unipole and Multipole Connectors

Unipole and Multipole Connectors Unipole and Multipole Connectors Miniature Cylindrical Connectors With Push-Pull-Locking Shenzhen Medplus Connector Co.,Limited. 2 th Floor,Ming An Street,GongMing Town, Baoan District, Shenzhen, China

More information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated

More information

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION

More information

EMC 2 CABLE GLANDS INTRO EMC 2 SERIES. Tighten the cable gland to the housing. Remove outer sheath of shielded cable. Insert cable until EMC spring.

EMC 2 CABLE GLANDS INTRO EMC 2 SERIES. Tighten the cable gland to the housing. Remove outer sheath of shielded cable. Insert cable until EMC spring. EMC 2 CABLE GLANDS These EMC cable glands combine several advantages in one product. First, you get the same clamping ranges as the standard brass glands. The protection class is IP68. In order to get

More information

Interface Connectors for Miniature, Portable Terminal Devices

Interface Connectors for Miniature, Portable Terminal Devices NEW Interface Connectors for Miniature, Portable Terminal Devices ST Series Strong locking mechanism Right Mating direction Left Top 9N max. Overview Developed as external input/output connectors for the

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

INVISILED ACCESSORIES

INVISILED ACCESSORIES Indoor mounting accessories v" 5 feet LED-T-CH Aluminum Channel Includes a diffuser, two end caps, and five screws a" 2 pcs LED-T-CH-EC End caps for Aluminum Channel 1" 5 feet LED-T-CH1 Deep Aluminum Channel

More information

>Inductive and CATALOG. Capacitive Sensors

>Inductive and CATALOG. Capacitive Sensors >Inductive and CATALOG Capacitive Sensors DATALOGIC: SOLUTIONS FOR INDUSTRIAL AUTOMATION Datalogic Industrial Automation is an industry-leader in products and solutions for material handling, traceability,

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

10 PDUs 19 PDUs Zero-U PDUs

10 PDUs 19 PDUs Zero-U PDUs 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3

More information

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59 75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59 RF Connectors Technical Data Sheet PE44625 Configuration BNC Male Connector 75 Ohms Straight Body Geometry Features Max Operating

More information

>Inductive. REFERENCE guide. Proximity

>Inductive. REFERENCE guide. Proximity >Inductive REFEREE guide Proximity DATALOGIC: SOLUTIONS FOR INDUSTRIAL AUTOMATION Datalogic Industrial Automation is an industry-leader in products and solutions for material handling, traceability, inspection

More information

LCS2 Cat. 6 RJ 45 Patch panels and units

LCS2 Cat. 6 RJ 45 Patch panels and units 87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

The Custom Interconnect Leader TM

The Custom Interconnect Leader TM LC Series.5.188.685 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: 50 ohms DC to 1.0 GHz 5,000 volts rms 3,000 volts rms 5,000

More information

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

75 Ohm N Male Connector Crimp/Solder Attachment for RG6 75 Ohm N Male Connector Crimp/Solder Attachment for RG6 RF Connectors Technical Data Sheet PE4508 Configuration N Male Connector 75 Ohms Straight Body Geometry Features Max Operating Frequency 15 GHz Good

More information

Connectivity for Ethernet

Connectivity for Ethernet Industrial Ethernet standards such as Modbus TCP, EtherNet/IP, PROFINET and Ether- CAT have firmly established themselves in automation technology. These real-time Ethernet solutions differ both in terms

More information

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................

More information

Capacitive sensor BCT5-S18-UP6X2T-H1151

Capacitive sensor BCT5-S18-UP6X2T-H1151 M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product

More information

Speed sensor MiniCoder GEL 2471

Speed sensor MiniCoder GEL 2471 Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless

More information

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

1 Inductive proximity switches. 5 Connecting cables. Highlights: New: Highlights: - All-metal housings - Miniature sizes - Long operating distances - Extreme environmental conditions - Analog outputs New: - All-metal devices for food industry and sea-water applications -

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

KVT Split cable glands

KVT Split cable glands KVT Split cable glands Description Type Order Inserts KT Thread PU No. small large Thread length KVT is a circular split frame for quick and easy installation of cables or complete cable harnesses. Polyamide

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151 Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:

More information

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit   for more information SECTION 9 BNC/BNC 75 HDTV/BNCTRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON Visit www.radiall.com for more information Contents BNC Introduction... 94 to 95 Interfaces... 96 to 97 Characteristics...98

More information

MCX Miniature Coaxial Connectors

MCX Miniature Coaxial Connectors ONLINE CATALOG MCX Miniature Coaxial Connectors 104 John W. Murphy Drive P.O. Box 510 New Haven, CT 06513 www.aepconnectors.com e-mail: aepsales@aepconnectors.com Mating Interfaces MCX Miniature Coaxial

More information

Control cabinet interface and cable entry systems

Control cabinet interface and cable entry systems Modlink MPV Control cabinet interface The Modlink MPV control cabinet interface provides the connection from the control cabinet to the fieldbus environment (outside) in a simple way. Durable connection

More information

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes XLRnet CONNECTORS XLRnet CONNECTORS XLRnet was designed in conjunction with the Amphenol Data / Telecom product group of Amphenol Canada Corp., a subsidiary of Amphenol Corporation. Utilising our combined

More information

PL Series. Plastic Push Pull Interconnects

PL Series. Plastic Push Pull Interconnects PL Series Plastic Push Pull Interconnects We Connect When it matters most For more than a century, ITT Cannon has developed innovative interconnect solutions for the world s most critical applications.

More information

Eddy Current Probe System

Eddy Current Probe System CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

MODEL HS35 DRAWWORKS OPTICAL ENCODER

MODEL HS35 DRAWWORKS OPTICAL ENCODER MODEL HS35 DRAWWORKS OPTICAL ENCODER Product Description This specially configured DrawWorks Model HS35 encoder combines rugged, heavy-duty features into a unique through-shaft style for use as a winchturns

More information

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200

More information

DIN EUROCARD CONNECTORS

DIN EUROCARD CONNECTORS DIN 41612 EUROCARD CONNECTORS 2230 SERIES SERIES. Vertical Female Type Half B Connectors. PCB Solder 4mm Wrap post tail length 13mm Wrap post tail length 17mm Soldar cable 16 a 2230 T061 2230 T063 2230

More information

SMA - 50 Ohm Connectors

SMA - 50 Ohm Connectors Alphabetical Index 142-0593-001 6 142-0593-006 6 142-0593-401 6 142-0593-406 6 142-0594-001 6 142-0594-006 6 142-0594-401 6 142-0594-406 6 142-0693-001 4 142-0693-006 4 142-0693-051 5 142-0693-056 5 142-0693-101

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

ZDC RF Coax Connector Series 50 & 75 Ohm

ZDC RF Coax Connector Series 50 & 75 Ohm CONTACTORS CONNECTORS WIRE & CABLE EMI/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATIO I/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATION & LABELING PCB & CABLE ASSEMBLIES

More information

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

Binder LED more than light!

Binder LED more than light! Binder LED more than light! Binder Connector Group Leading in the Way of Development and Manufacturing Connectors for Industrial Applications and Automation Technology The Binder Connector Group, headquartered

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Small Circular Connector. JN1/JN2 Series. Dust Cap

Small Circular Connector. JN1/JN2 Series. Dust Cap COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Small Circular Connector JN1/JN2 Series Angle Plug CONNECTOR MB-0054-8 October 2009 [JN1] [JN2] [JN1] [JN2] Straight Plug Cable Connecting Individual Plug

More information

LED Series Sealed Backlights

LED Series Sealed Backlights For use with any Vision system Rugged, waterproof housing, rated IEC IP67 Mounts directly from the back or surface mount using available brackets Smooth exterior for easy cleaning Diffused backlights for

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

Product Data Sheet

Product Data Sheet Product Data Sheet www.moteck.com Actuator ID11 ID11 is designed for industrial applications, such as agricultural and construction machines. Comparing with ID1, the installation length of ID11 is 4mm

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803

More information

1.2 EUREKA Series... from page c.14

1.2 EUREKA Series... from page c.14 .2 EUREKA Series................................................................................................. from page c.4 This latest generation of industrial plugs, connectors and socket outlets

More information

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products

More information

Swiveling unit. Smooth and precise swiveling

Swiveling unit. Smooth and precise swiveling NEW Swiveling unit RSP-FLEX Smooth and precise swiveling Swiveling unit RSP-FLEX Especially with automated loading and unloading of machine tools, the RSP-Flex swivel units offer an alternative to expensive

More information

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling NEW SWIVELING UNIT RSP-FLEX Smooth and precise swiveling SWIVELING UNIT RSP-FLEX Especially with automated loading and unloading of machine tools, the RSP-Flex swivel units offer an alternative to expensive

More information

senes FM Magnetic sensors for cylinders series FM100 - FM101 - FM157 - FM158 agnetic sensors for cylinders series

senes FM Magnetic sensors for cylinders series FM100 - FM101 - FM157 - FM158 agnetic sensors for cylinders series series FM100 - FM101 - FM157 - FM158 senes FM Magnetic sensors series "FM" allow to detect trie magnetic pistón position inside pneumatic cylinders. The magnetic field generated in trie cylinder is used

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

12G Broadcast connectors

12G Broadcast connectors 12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high

More information

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:

More information