CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

Size: px
Start display at page:

Download "CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES"

Transcription

1 CET DOUBLE COUNTER WITH TWO THRESHOLDS Type: LBM62CD 6 DIGITS DOUBLE DIGITAL COUNTER WITH TWO SEPARATE COUNT IMPUTS LBM62CD counter is a double counter with two separate counters. Each counter s input is independent from the other one. MAIN FEATURES Frontal keyboard in polycarbonate (antiscratch, antioil, antiacid). IP65 protection degree Accessible parameters with key software Removable terminals connection. Execution DIN 48 x 96. Recessed assembly. Special retaining brackets. PROGRAMMABLE PARAMETERS Two Threshold Reset Time Multiplication factor of the impulses Input (Slow / Fast) Count (Up / Down / Superior) Reset key Decimal Point Counting Input POWER SUPPLY IN ALTERNATE CURRENT POWER SUPPLY IN DIRECT CURRENT POWER SUPPLY TOLERANCE ABSORPTION OPERATING TEMPERATURE CLIMATIC CONDITIONS COUNTER VISUALIZATION BATCH COUNTER VISUALIZATION MULTIPLICATION COEFFICIENT THE INPULSES IN INPUT INPUT TYPE (NPN or PNP) MINIMUM TIME FOR SLOW INPUT SIGNALS CUT FREQUENCY FOR ELECTROMECHANICAL INPUTS AUXILIARY INPUTS POWER SUPPLY (version /5 /2 /24 VDC on demand) COMMAND IMPUTS OUTPUTS RELAY RESET PROGRAMMED DATA MEMORY TECHNICAL FEATURES : Single power Vac (50 / 60 Hz). : Single power 24 Vdc : +0% - 5%. : 2 W - 3 VA. : -5 C + 55 C. : U.R. 95 % at 40 C (without condensate). : 6 digits, 4mm high : 5 digits, 4mm high : Programmable from 0,0000 to 9, : Suitable for Single directional Encoder, Proximity, electromechanical and logical signals up to 20KHz. : Programmable in 25%, 50% and 75% of the frequency. : from 25 to 00 Hz. : 24 Vdc - 80 ma available on terminals. : 2 Vdc - 80 ma available on terminals.. : 5 Vdc - 80 ma available on terminals. : Counter Reset : Inhibit Counter : Inhibit Counter 2 : 2 relays with operating contacts - capacity 2A - 250Vac. : Manual or automatic with excitation time from 0, to 99,9 sec. : static (no battery) CET - s.r.l. Vers..2 LBM 62CD Pag.

2 DESCRIPTION OF THE FRONTAL KEYBOARD ø YELLOW ù YELLOW ú BLUE û RED The key 'LEFT ARROW' in normal operating phase visualizes, blinking, all the programmings executed without the limitation of the insertion code. The time of scansion of the programmings is given from the pressure of the same key. It exits automatically from this phase after 5 sec of the last pressure of the same key. In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is on the right side first one on the. At the end it resumes from the first one to right. The key 'UP ARROW' visualizes, in alternative mode, CNT and CNT2 In programming phase it increases the value of the blinking figure. The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display C In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The instrument exits automatically from the programming phase, 60 sec. after the pressure of the last key. The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it attributed in the programming phase. In programming phase it confirms and memorizes the visualized data and passes to the successive function. If it has arrived to list end it resumes from the beginning. INPUTS / OUTPUTS DESCRIPTION DC POWER (inputs - 2) AC POWER (inputs 3-4) 24 VDC - 80mA (inputs 6-7) RESET (input 9) INHIBIT (input 9) INHIBIT 2 (input 0) CNT (input ) CNT 2 (input 2) RL (inputs 4-5-6) RL2 (inputs 7-8-9) 24V DC Power Supply of the instrument. Power Supply of the instrument; it can be to VAC according to demand. 24 VDC - 80 ma auxiliary Power Supply that the instrument supply to feed Encoder and amplified proximity. Input of RESET that executes the reset of the visualized count showed on display at the moment of its activation. When active, it operates as inhibit of the counting When active, it operates as inhibit of the counting 2 NPN counting input (PNP on demand) suitable for electromechanical contacts, amplified proximity, 3 wires sensors and single directional Encoders for CNT NPN counting input (PNP on demand) suitable for electromechanical contacts, amplified proximity, 3 wires sensors and single directional Encoders for CNT2 Output of Relay, connected to the operation of the Threshold S. The Common and Normally Opened contacts are available. Output of Relay 2, connected to the operation of the Threshold S2. The Common and Normally Opened contacts are available. DESCRIPTION OF THE LED S OPERATION LED It comes activated to the reaching of the Threshold S. LED 2 It comes activated to the reaching of the Threshold S2. CET - s.r.l. Vers..2 LBM 62CD Pag. 2

3 COUNTERS VISUALIZATION Normally, the instrument shows the value of CNT counter; this is highlighted by a on the small display on the lower left. With Arrow UP key it is possible to show the value of CNT2 counter, highlighted by a on the small display on the lower left. Pressing Arrow UP again the display shows the CNT s value Visualization of CNT counter Visualization of CNT2 counter For THRESHOLDS programming access, proceed as follow: - Press key PRG in impulsive mode; on display appears: PROGRAMMING OF THRESHOLDS S. = Threshold of CNT counter, programmable between 0 and S.2 = Threshold of CNT2 counter, programmable between 0 and Key ENT confirms the data and passes to the successive programming. In order to exit the programming, press key PRG. PROGRAMMING OF THE OPERATION PARAMETERS The programmable parameters are divided in two groups and protect with a 4 figures code. In order to approach the programming, proceed in the following way: - Press key PRG for about 2 sec. On the display appears: Cod 0000 Ì 0 Ì2 0 ¾ 000 ¾ 000 GROUP : insert code 2357 and press ENT. t. = Automatic Time Reset of counter CNT, programmable from 00,0 up to 99,9 sec. This parameter allows to the instrument to operate in automatic mode. When the counting reach the S value automatically it resets the counting, excites the relay RL and restart the counting without lose impulses. The relay RL remains ON for time programmed in t.. programming. If the reset time programmed in t.. is = 0 (00,0) the instrument operates in manual mode. Particular case: if the set up time t.. is smaller of the time employed from the count to arrive to the values of S. or S.2, the relative relays will never come unactived. t.2 = Automatic Time Reset of counter CNT2, programmable from 00,0 up to 99,9 sec. This parameter allows to the instrument to operate in automatic mode. When the counting reach the S value automatically it resets the counting, excites the relay RL2 and restart the counting without lose impulses. The relay RL2 remains ON for time programmed in t.2. programming. If the reset time programmed in t.2. is = 0 (00,0) the instrument operates in manual mode. Particular case: if the set up time t.2. is smaller of the time employed from the count to arrive to the values of S. or S.2, the relative relays will never come unactived. F. = 4 digits multiplier Factor, programmable from 0, to This parameter allows to convert the number of the input impulses, showing them on the display in another format. If it programmed = 0 it comes reprogrammed automatically to. If a value lower than is inserted, it obtains the division of the impulses. Es. I want to divide for 25 the impulses in input; calculation : 25 = Attention: the variation of the value of the multiplying modifies automatically the value of the counting. F. = 4 digits multiplier Factor, programmable from 0, to This parameter allows to convert the number of the input impulses, showing them on the display in another format. If it programmed = 0 it comes reprogrammed automatically to. If a value lower than is inserted, it obtains the division of the impulses. Es. I want to divide for 25 the impulses in input; CET - s.r.l. Vers..2 LBM 62CD Pag. 3

4 calculation : 25 = Attention: the variation of the value of the multiplying modifies automatically the value of the counting. æ F æ 5 æ Æ æ2 F æ2 5 æ2 Æ CnÌ UP CnÌ dæ CnÌ SÈ CnÌ2 UP CnÌ2 dæ CnÌ2 SÈ Input CNT = Fast - Slow - Medium. This programming allows to set the input of CNT counter to read electromechanical signals or logical signals: In = F. Fast, input CNT can read logical signals up to 20 KHz. In = S. Slow, input CNT can read electromechanical signals up to 25 Hz. In = M. Medium, input CNT can read electromechanical or logical signals up to 00 Hz. Input CNT2 = Fast - Slow - Medium. This programming allows to set the input of CNT2 counter to read electromechanical signals or logical signals: In = F. Fast, input CNT2 can read logical signals up to 20 KHz. In = S. Slow, input CNT2 can read electromechanical signals up to 25 Hz. In = M. Medium, input CNT2 can read electromechanical or logical signals up to 00 Hz. Cnt. = Counting Mode of CNT counter: UP / DOWN / Superior. UP = UP counting on rising edge dn. = DOWN counting on rising edge SP. = SUPERIOR, counting on rising edge getting over the Threshold. Counting = Up: the counter gets ready to visualize the UP counting in rising edge mode, starting from zero up to the programmed value of Threshold. To the counting s end it actives RL relay output. Counting = dn: the counter gets ready to visualize the DOWN counting in rising edge mode, starting from the programmed value of Threshold to zero. To the counting s end it actives RL relay output. This programming operates with positive Thresholds only; negatives Thresholds are reprogrammed to 0. Count = Sp: The operation is similar to UP Counting with the difference that to the reaching of the threshold the instrument continues to count and can manually be resets to zero only. Cnt.2 = Counting Mode of CNT2 counter: UP / DOWN / Superior. UP = UP counting on rising edge dn. = DOWN counting on rising edge SP. = SUPERIOR, counting on rising edge getting over the Threshold. Counting = Up: the counter gets ready to visualize the UP counting in rising edge mode, starting from zero up to the programmed value of Threshold. To the counting s end it actives RL2 relay output. Counting = dn: the counter gets ready to visualize the DOWN counting in rising edge mode, starting from the programmed value of Threshold to zero. To the counting s end it actives RL2 relay output. This programming operates with positive Thresholds only; negatives Thresholds are reprogrammed to 0. Count = Sp: The operation is similar to UP Counting with the difference that to the reaching of the threshold the instrument continues to count and can manually be resets to zero only. Key ENT confirms the data and passes to the successive programming. In order to exit the programming, press key PRG. CET - s.r.l. Vers..2 LBM 62CD Pag. 4

5 PROGRAMMING OF THE OPERATION PARAMETERS The programmable parameters are divided in two groups and protect with a 4 figure code. In order to approach the programming, proceed in the following way: - Press key PRG for about 2 sec. On the display appears: Cod 0000 NeÆ Ñ NeÆ æ GROUP 2: insert code 243 and press ENT. Active or excluded memory. This parameter allows to program the saving of the current counter value during the power off the instrument. MEM. Y. = memorization of the count during the power off. When power on the instrument the display will visualize the last present value in the power off phase. MEM. n. = excluded memorization of the count; every time that the instrument comes powered off and then powered on the count comes lost and the instrument restart always from the initial condition. 2 RreË E reë d êcnì e êcnì d CnÌ2 CnÌ2 2 ȼ 0 ȼ 5 ȼ2 0 ȼ2 5 RESET Key E / d; this programming enables and disables the RESET function of frontal key RES during the operation of the counter. RES. E = RESET function of key RES enabled RES. d. = RESET function of key RES disabled r.cnt. = RESET INPUT MODE. ; this programming enables and disables the RESET function of input RESET during the operation of the counter d. = RESET disabled. The function of input RESET is disabled; it s not possible to reset CNT counter. E. = RESET enabled. The function of input RESET is enabled; it s possible to reset CNT counter... r.cnt. 2 = RESET INPUT MODE. ; this programming enables and disables the RESET function of input RESET during the operation of the counter d. = RESET disabled. The function of input RESET is disabled; it s not possible to reset CNT2 counter. E. = RESET enabled. The function of input RESET is enabled; it s possible to reset CNT2 counter. Cnt.2 = Function of CNT2 counter. 2 = The function of CNT2 counter is independent; CNT and CNT2 counters work like two separated counters. = The input of CNT2 is disabled and CNT2 works as a batch counter: every time CNT reach the set point, CNT2 increase its value by step. Programming of the Decimal Point of the Counter CNT. This programming allows to add a decimal point to the visualization on the 5 digits, in order to obtain counts with various resolutions. d.p. = 0 Decimal Point excluded; visualization d.p. = Decimal Point on the second display from right; visualization 99999,9 d.p. = 2 Decimal Point on the third party display from right; visualization 9999,99 d.p. = 3 Decimal Point on the quarter display from right; visualization 999,999 d.p. = 4 Decimal Point on fifth display from right; visualization 99,9999 Attention, the Decimal Point is only fictitious, it doesn't realize any conversion. Programming of the Decimal Point of the Counter CNT2. This programming allows to add a decimal point to the visualization on the 5 digits, in order to obtain counts with various resolutions. d.p. = 0 Decimal Point excluded; visualization d.p. = Decimal Point on the second display from right; visualization 99999,9 d.p. = 2 Decimal Point on the third party display from right; visualization 9999,99 d.p. = 3 Decimal Point on the quarter display from right; visualization 999,999 d.p. = 4 Decimal Point on fifth display from right; visualization 99,9999 Attention, the Decimal Point is only fictitious, it doesn't realize any conversion. CET - s.r.l. Vers..2 LBM 62CD Pag. 5

6 0í î 0í 0í2 î 0í2 Programming of the OUTPUT RL. This parameter allows to activate the RLrelay to the beginning î or to the end of the count. Ou. î = the Activation of the RL relay to end of count Ou. = the Activation of the RL relay to beginning of count Programming of the OUTPUT 2 RL2. This parameter allows to activate the RLrelay to the beginning î or to the end of the count. Ou.2 î = Activation of the RL2 relay to end of count Ou.2 = Activation of the RL2 relay to beginning of count ¹È ¹È ê Activation mode of the programmed parameters. With this programming is possible to activate the executed programmings directly during the programming or, when exited of the programming, after a RESET (with frontal key or from rear input) Key ENT confirms the data and passes to the successive programming. In order to exit the programming, press key PRG. CET - s.r.l. Vers..2 LBM 62CD Pag. 6

7 Borgolavezzaro,October, 03rd 2005 DECLARATION OF CE CONFORMITY The building firm: CET s.r.l. Head office: Strada Statale 2, Km 53, Borgolavezzaro (No) ITALY declare that the product: type: model: use class: Digital Electronic Counter LBM62CD Industrial is in conformity with the following normatives: EN550 ENV504 ENV50204 EN EN The manufacturing: CET S.r.l. SENSORS CONNECTIONS Signature KEY VDC CNT2 CNT INHIBIT RESET RESTART GND CNT2 CNT INHIBIT RESET RESTART Contatto Open collector Transistor Encoder, Proximity amplified or 3 wires NPN SENSORS 7 GND LBM Terminals PNP SENSORS 6 +24VDC LBM Terminals Voltage Level Bi-directional Encoder CET - s.r.l. Vers..2 LBM 62CD Pag. 7

8 CONNECTIONS IN NEGATIVE LOGIC NPN RL2 RL CONNECTIONS IN POSITIVE LOGIC PNP RL2 RL DC AC POWER SUPPLY + - 2Vdc 80mA INHIBIT CNT RESET INHIBIT 2 CNT2 NPN - + DC AC POWER SUPPLY Vdc 80mA INHIBIT CNT CNT2 PNP RESTART INHIBIT 2 24 VDC POWER SUPPLY TRANSISTORS OUTPUTS DC AC POWER SUPPLY Vdc 80mA When the instrument is fed to 24 VDC connect the input 5 and 7 as showed. OUT2 OUT Max. Voltage 30VDC - Max. Current 00 ma OVERALL DIMENSIONS (mm) FRONTAL 96 REMOVABLE TERMINALS SIDE RETAINING BRACKETS L L2 - CET ENT PROG RES Electronic counter LBM 48 44x REAR 92 DRILL TEMPLATE CET CET CET CET s.rl. Strada Statale 2 Km 53, Borgolavezzaro - NO - ITALY Tel : /88530/ Fax : info@cet-italy.com Agent: CET - s.r.l. Vers..2 LBM 62CD Pag. 8

VISUALIZED DIGITAL TIMER

VISUALIZED DIGITAL TIMER CET VISUALIZED DIGITAL TIMER WITH ONE SET POINT Type: NTM52 THE INSTRUMENTS OF SERIES NTM ARE DIGITAL INSTRUMENTS WIDE USABLE IN THE INDUSTRY FOR THEIR PROGRAMMABLE CHARACTERISTICS AND THE FLEXIBILITY

More information

02/11/2015

02/11/2015 24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL F90 Series (Rate Indicators / Controllers) INSTRUCTI MANUAL FEATURES DIN 48 9mm DIN 48 9mm Standard Panel Size Monitor & Preset Type 1 Monitor type with the large display 2 Preset Type can make the upper/lower

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

Eaton Durant. Counters, process instruments and hour meters.

Eaton Durant. Counters, process instruments and hour meters. Alltid Always tillgänglig available - Alltid öppen! - Always open! Electronic totalizers, LCD display - 1/32 DIN 24x mm Eaton Durant Catalogue Weight Type number kg/each Totalizer, add/subtract, NPN/PNP

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com FS340 and FS641 High Performance

More information

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904 Operating Instructions 3.96.3 (ed. 5.97) Electronic Preset Counter Type Series 904 1. Description 6 digit preset counter, 2 presets, add./subtr. bright 2-line LCD display with symbols for activated outputs

More information

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions CT340 and CT641 High Performance Low Cost Controller for Rotating Cutters and Printing Rolls Precision controller for Rotating Cutters and Printing Rolls Easy parameter setting and immediately ready to

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information

Electronic Pulse Counter Combination device

Electronic Pulse Counter Combination device Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic

More information

Page 1 of 7 Preselection and multifunction up/down counters 48x48 - CPT4 - Electronic multifunction counters CPT4 - LCD - 6 x 9 mm digits Selling points of the range Preselection counter, Tachometer, Timer,

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...

More information

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Flexible Counter Series in DIN size 24 x 48 mm

Flexible Counter Series in DIN size 24 x 48 mm Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Flexible Counter Series in DIN size 24 x 48 mm

Flexible Counter Series in DIN size 24 x 48 mm Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or

More information

Digital differential pressure controller Model DPD Instruction manual

Digital differential pressure controller Model DPD Instruction manual Digital differential pressure controller Model DPD Instruction manual DPDeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

REGO Start&Go USER MANUAL

REGO Start&Go USER MANUAL REGO Start&Go USER MANUAL Version 0 Rev. B of 03/03/16 Page 1 of 15 Introduction The purpose of the manual is to describe all of the steps required to commission and correctly operate the REGO Start&Go

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

Solution Selection Guide

Solution Selection Guide Solution Selection Guide 2015-2016 Automation Systems Motion & Drives Sensing Control Components Switching Components Safety Digital Panel Meters Contents Selection Guide W-ii K3HB -X, -H, -V, -S Process,

More information

SERIES 400 SERIES 620

SERIES 400 SERIES 620 x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x

More information

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL !!! ATTENTION - NOTICE FOR THE INSTALLER!!! The bridges present on the contacts STOP, SENSITIVE EDGE, PHOTOCELLS, will not be installed anymore

More information

MARCO CORNER, 19/ THIENE (VI) ITALIA

MARCO CORNER, 19/ THIENE (VI) ITALIA DECLARATION OF CONFORMITY KOLVER S.r.l. VIA MARCO CORNER, 19/21 36016 THIENE (VI) ITALIA Declare that the new machine here described: ACE Screw Counter Is in conformity with the following standards and

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

Operating instructions - High Performance LED Timer / / /

Operating instructions - High Performance LED Timer / / / Operating instructions - High Performance LED Timer 0 742 201/ 0742 202/ 0 742 251/ 0 742 252 Your tico 742 timer is a powerful instrument which can be field configured to fit a wide variety of applications.

More information

SPACESCAN SERIES SS 02

SPACESCAN SERIES SS 02 Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc

More information

Preset counters, electronic

Preset counters, electronic LCD preset counters Adding or subtracting (battery) 901 Type 901 is a simple battery powered preset pulse counter with 12... 250 V AC/DC count and reset input. The 6-digit, 2-line LCD display shows the

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly The Codix 923/924 can be used universally. As a preset pulse counter, tachometer or preset timer with up to 6 presets it is able to solve a very wide range of control and monitoring tasks in every application.

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic preselection counter Contents Page 1 General Information / Safety instructions 2 2 Getting to know the counter 4 2.1 Counter components 4

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Hour Meters / Timers, electronic

Hour Meters / Timers, electronic Hour Meters / Timers, electronic LED Timers Codix 523 For use as a timer, hour meter or short-time meter Pulse width measurement (operating time) Time interval measurement (start/stop) DC 000000 0... 30V

More information

CAM PROGRAMMER MCA 116

CAM PROGRAMMER MCA 116 CET s.r.l. CAM PROGRAMMER MCA 116 User manual Version 1.00 CET s.r.l. - S.S. 211 Km 53 28071 Borgolavezzaro (NO) Tel. 0321-885180 / 885301 FAX. 0321-885560 CET s.r.l. CAM PROGRAMMER MCA 116 INDEX 1. GENERAL

More information

Self--powered Time Counter

Self--powered Time Counter Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to

More information

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14) SPECIFICATIONS / INSTALLATION / OPERATION MEASUREMENT SOLUTIONS MMRT Bulletin SS09040 Issue/Rev. 0.2 (10/14) We put you first. And keep you ahead. Smith Meter TOTALIZER/RATE METER The MMRT is a combination

More information

Programmable Speed Monitor. rotas. Operating Instructions CR CRR CRA CRRA. RHEINTACHO Messtechnik GmbH Waltershofener Straße Freiburg Germany

Programmable Speed Monitor. rotas. Operating Instructions CR CRR CRA CRRA. RHEINTACHO Messtechnik GmbH Waltershofener Straße Freiburg Germany Operating Instructions BA: N0000.225B/05..2005 Programmable Speed Monitor rotas CR CRR CRA CRRA RHINTACHO Messtechnik GmbH Waltershofener Straße 1 79111 Freiburg Germany Tel. +49 (0)761 45 13-0 Fax +49

More information

MULTIS L72. Operating instructions

MULTIS L72. Operating instructions GB MULTIS L72 Operating instructions 2 SOCOMEC - Ref. : 876 091B ENGLISH GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 5 PRESENTATION 4 INSTALLATION 5 Mechanical environment Climatic environment

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2 LEVEL CROSSING MODULE FOR LED SIGNALS LCS2 Fully Flexible Controller for Common-Anode LED signals Automatically detects trains using an infra-red sensor mounted below the track bed Operates attached yellow

More information

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according

More information

7 Day Digital Time Switch

7 Day Digital Time Switch 7 Day Digital Time Switch Model: NTT08 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2.

More information

SAUTER flexotron RDT405 Manual

SAUTER flexotron RDT405 Manual SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties

More information

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

Pulse Counters, electronic

Pulse Counters, electronic LCD Pulse Counters Codix 0 RoHS Low-price and high efficiency Large -digit LCD display, height of the figures mm [0. ] Optional backlighting Simple counter for fast and slow count pulses, counting direction

More information

Digital Time Switch. Installation & Operating Instructions

Digital Time Switch. Installation & Operating Instructions Digital Time Switch Model: NTT06 24 Hour General Purpose Digital Timer Model: NTT07 7 Day General Purpose Digital Timer Installation & Operating Instructions 1 1. General Information These instructions

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual TDEPD Field-Programmable Pressure Switch/Transducer with Integrated LED Display Programming Sequence Manual Wiring Diagram Pin5 Maintenance Mode + Gray Vent Pin2 Digital Output 2 +/ Analog Output + White

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised SECU-16 Introduction The SECU-16 module allows 8 inputs and 8 low-current relay outputs to be added to an ADICON control system. The inputs may be supervised (switch closure), analog, or 4-20mA. Specifications

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

ATS50SAW Programmable Selective Amplifier

ATS50SAW Programmable Selective Amplifier ATS50SAW Programmable Selective Amplifier Technical Specifications N Input BI/BII (40 108 MHz) 1 N Input BIII/DAB (170 320 MHz) 1 N AUX input (40 860 MHz) 1 N Programmable Input UHF (470 790 MHz) 4 N IF-SAT

More information

Model IQ4-PC User Manual Revision Date:

Model IQ4-PC User Manual Revision Date: Basic Specifications Supply Volts 230V 50/60Hz ±15% 115V 50/60Hz ±15% 24V DC (isolated) ±15% Power Consumption Max. 3VA (IQ4-PC-R0) Max. 6VA (IQ4-PC-R2-PSI24-RT) Operating Temperature -5 ~ +60 C Operating

More information

PRO-CTR100/200 Counter/Rate Controller

PRO-CTR100/200 Counter/Rate Controller PRO-CTR100/200 Counter/Rate Controller 1 This advanced controller is ideal for a wide variety of rate monitoring and batching applications. It is available with either a single or dual display, and has

More information

AT450SAW Programmable Selective Amplifier

AT450SAW Programmable Selective Amplifier AT450SAW Programmable Selective Amplifier LEMELETTRONICA srl Via Grezze 38 25015 Desenzano del Garda (BS) ITALY Tel. +39 030-9120006 Fax +39 030-9123035 www.lemelettronica.it Technical Specifications

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7 TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7 FRONT PANEL OPERATIONS...8 PROGRAMMING FLOW CHART...8 DEFINITIONS OF MENU

More information

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS UNI EN ISO 9001 C R US MULTITURN SOLUTE ENCODER PROFIUS Presentation The ELTR Profibus multi-turn encoder (Identification Number 0x0599) conforms to the Profibus DP standard, described by European Standard

More information

STD-525T PRECISION TIMER

STD-525T PRECISION TIMER FN:STD525TM1.DOC STD-525T PRECISION TIMER DESCRIPTION The STD-525T Precision Timer measures and displays accurate elapsed time in minutes, seconds, tenths of seconds, and hundredths of seconds (MM.SS.TH)

More information

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays Operation Manual TX20 1/8 DIN Microcomputer Based /ORP Controller with relays 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

BC104 BATCH CONTROLLER

BC104 BATCH CONTROLLER Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 www.anderson-negele.com Instrument Model Number Instrument Serial Number ANDERSON INSTRUMENT COMPANY

More information

VAT 20 Adjustable Frequency Drive

VAT 20 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive

More information

FRQM-2 Frequency Counter & RF Multimeter

FRQM-2 Frequency Counter & RF Multimeter FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)

More information

XTM72 Exerciser Timer Module

XTM72 Exerciser Timer Module Capricorn Controls DA01XTM1-1 Data & Application Note Page 1 of 6 XTM72 Exerciser Timer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products This

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

Digital Ratio Controller

Digital Ratio Controller Digital Ratio Controller RSC-406 Control Panel USER S MANUAL RATIO CONTROLLER SPEED RUN PRG ERR RATIO % CH RSC-406 Prelude Thank you for applying our RSC-406 Ratio Controller (abb.406) to you machinery

More information

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com ZU 251 Incremental Counter Module

More information

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346 control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com AX 346 Process Indicator with Two

More information

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets CODIX 560 Elektronischer Vorwahlzähler mit zwei Vorwahlen Electronic Preset Counter With two presets Compteur à présélection électronique avec deux présélections Contatore elettronico a preselezione con

More information

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface control motion interface ZU 252 Incremental Counter Module With Analogue Output and Serial Interface Counter suitable for quadrature signals (A/B, 90º) as well as single channel inputs Counting inputs

More information