Download "relays Electromechanical 2006 /2007"

Transcription

1 1 Electromechanical relays 2006 /2007 miniature relays industrial relays automotive relays interface relays plug-in sockets and accessories

2 2 Relays and Sensors - our business! Established in 1935 to manufacture switching devices for power generation Durakool is a renowned manufacturer of switching and sensing components used in industrial and power automation, power electronics, industrial electronics, automotive and telecommunication applications. American Electronic Components and Durakool provide their partners with technical consultation based upon extensive application knowledge and experience. After many years of development and innovation, we understand that quality is paramount and we pursue a policy of continuous improvement. For more in depth information and data sheets, visit our web site at Due to the very wide product range, please consult us or your distributor for non-standard items.

3 3 Controlling electricity for over 70 years! American Electronic Components and Durakool offer an extensive range of: ELECTROMECHANICAL RELAYS AND CONTACTORS MERCURY RELAYS AND CONTACTORS TILT AND TIP-OVER SWITCHES FLOAT SWITCHES LIQUID LEVEL SENSORS G-FORCE SENSORS AND SWITCHES HERMETIC SEALS, FEED THROUGHS AND SIGHT GLASSES

4 4 Miniature relays Type of relay DM84 DM85 DM87 ❹ ❶ Standard contact materials are marked with bold type. ❷ Between coil and contacts ❸ Clearance / creepage ❹ Type of pin layout: N in (3.5 mm) pin layout, L in (5 mm) left pin layout, P in (5 mm) right pin layout ❺ WT (mechanical indicator + lockable front test button) ❻ IP 67 waterproof version (L x W x H) 1.14 x 0.5 x 0.62 in 1.14 x 0.5 x 0.62 in 1.14 x 0.5 x 0.62 in 29 x 12.7 x 15.7 mm 29 x 12.7 x 15.7 mm 29 x 12.7 x 15.7 mm Contact data Number and type of contacts DPDT, DPST SPDT, SPST SPDT, SPST Max. switching voltage 400 V AC / 300 V DC 400 V AC / 300 V DC 400 V AC / 300 V DC Rated current 100 A 80 A 60 A 40 A 30 A 20 A 10 A 8 A 16 A 12 A Contact material ❶ /Au 5 µm, AgSnO 2 AgSnO 2 /Au 5 µm, AgSnO 2 Coil data Rated voltage AC: V 50/60 Hz AC: V 50/60 Hz AC: V 50/60 Hz DC: V DC: V DC: V Rated power consumption AC: 0.75 VA AC: 0.75 VA AC: 0.75 VA DC: W DC: W DC: W General data Electrical life (AC1) > A, 250 V AC > 0.7 x A, 250 V AC > A, 250 V AC Mechanical life (cycles) > 3 x 10 7 > 3 x 10 7 > 3 x 10 7 Ambient temperature AC: o C AC: o C AC: o C operating DC: o C DC: o C DC: o C Weight 0.5 oz (14 g) 0.5 oz (14 g) 0.5 oz (14 g) Cover protection category or IP 67 ❻ or IP 67 ❻ or IP 67 ❻ Recognitions, certifications, directives Insulation dielectric strength ❷ 5000 V AC 5000 V AC 5000 V AC Contact - coil distance ❸ 10 / 10 mm 10 / 10 mm 10 / 10 mm Operating / release time 7 / 3 ms 7 / 3 ms 7 / 3 ms PC Board layout (solder side view) For other variations - see DM84 DPDT DM85 SPDT DM87P SPDT

5 Miniature and industrial relays 5 DM87N sensitive D2 ❺ D4 ❺ 1.14 x 0.5 x 0.62 in 29 x 12.7 x 15.7 mm 1.08 x 0.83 x 1.4 in 27.5 x 21.2 x 35.6 mm 1.08 x 0.83 x 1.4 in 27.5 x 21.2 x 35.6 mm Signalling / protection modules type DM6.. SPDT, SPST DPDT 4PDT 400 V AC / 300 V DC 250 V AC / 250 V DC 250 V AC / 250 V DC 10 A 12 A 6 A For plug-in sockets type: DZM80, DZM92, DZM2, DZM4 /Au 5 µm, AgSnO 2 /Au 0.2 µm, /Au 5 µm /Au 0.2 µm, /Au 5 µm DC: V AC: V 50/60 Hz DC: V AC: 1.6 VA AC: V 50/60 Hz DC: V AC: 1.6 VA DM61G: 6/24 V AC/DC DM62G: 24/60 V AC/DC DM63G: 110/230 V AC/DC DC: 0.25 W > 1.7 x A, 250 V AC > 3 x 10 7 DC: 0.9 W A, 250 V AC 2 x 10 7 DC: 0.9 W A, 250 V AC 2 x 10 7 Module L LED green color. No protection against polarity inversion. AC/DC voltage allowed. Coil energized indicator. DC: o C DC: o C DC: o C 0.5 oz (14 g) 1.2 oz (35 g) 1.2 oz (35 g) or IP 67 ❻ 5000 V AC 10 / 10 mm 2.5 / 4 mm 1.6 / 3.2 mm 7 / 3 ms AC: 10 / 8 ms, DC: 13 / 3 ms AC: 10 / 8 ms, DC: 13 / 3 ms Plug-in sockets and accessories for relays - see pages 10, 11. DM87N SPDT

6 6 Industrial relays Type of relay D15 DPDT D15 3PDT DUC ❶ Standard contact materials are marked with bold type. ❷ Between coil and contacts ❸ Clearance / creepage ❹ DUC11 limits max switching voltage up to 250 V AC/DC and coil rated voltage up to 240 V AC. ❺ Version with contact gap 3 mm ❻ High voltage relay (L x W x H) Contact data Number and type of contacts Max. switching voltage Rated current 100 A 80 A 60 A 40 A 30 A 20 A 10 A 1.38 x 1.38 x 2.14 in 1.38 x 1.38 x 2.14 in 35 x 35 x 54.4 mm 35 x 35 x 54.4 mm DPDT 3PDT 250 V AC / 250 V DC 250 V AC / 250 V DC 10 A 10 A 1.52 x 1.42 x 1.79 in 38.6 x 36.1 x 45.5 mm DPDT, 3PDT DPST, 3PST 400 V AC / 400 V DC ❹ 16 A Contact material ❶ /Au 0.2 µm, /Au 5 µm /Au 0.2 µm, /Au 5 µm AgCdO Coil data Rated voltage AC: V 50/60 Hz AC: V 50/60 Hz AC: V 50/60 Hz ❹ DC: V DC: V DC: V Rated power consumption AC: 2.8 VA 50 Hz 2.5 VA 60 Hz AC: 2.8 VA 50 Hz 2.5 VA 60 Hz AC: 2.8 VA 50 Hz 2.5 VA 60 Hz DC: 1.5 W DC: 1.5 W DC: 1.5 W (1.7 W ❺) General data Electrical life (AC1) 2 x A, 250 V AC 2 x A, 250 V AC A, 250 V AC Mechanical life (cycles) 2 x x Ambient temperature I =10 A: o C operating DC: o C DC: o C I =16 A: o C Weight 2.9 oz (83 g) 2.9 oz (83 g) 3 oz (85 g) Cover protection category Recognitions, certifications, directives Insulation dielectric strength ❷ Contact - coil distance ❸ 3 / 4.2 mm 3 / 4.2 mm 6 / 8 mm Operating / release time AC: 12 / 10 ms, DC: 18 / 7 ms AC: 12 / 10 ms, DC: 18 / 7 ms AC: 12 / 10 ms, DC: 12 / 7 ms Plug-in sockets and accessories for relays - see pages 10, 11.

7 Industrial relays 7 DB 16 A DB 30 A DLR DT ❻ 1.65 x 1.73 x 2.6 in 1.65 x 1.73 x 2.6 in 2.07 x 1.32 x max 2.09 in 2.36 x 1.89 x 2.75 in 42 x 44 x 66 mm 42 x 44 x 66 mm 52.5 x 33.5 x max 53 mm 60 x 48 x 70 mm SPDT, DPDT, 3PDT SPDT, DPDT, 3PDT SPST, DPST DPDT SPST, DPST, 3PST SPST, DPST, 3PST SPST, DPST 400 V AC / 400 V AC / 250 V AC / 5000 V AC / ❻ 16 A 30 A A 10 A AgCdO AgSnO 2 AgSnO 2 AC: V 50/60 Hz AC: V 50/60 Hz AC: V 50/60 Hz AC: V 50/60 Hz DC: V DC: V DC: V DC: V AC: 3.9 VA 50 Hz AC: 3.9 VA 50 Hz AC: VA DC: 2.0 W DC: 2.0 W DC: 1.9 W DC: 5.5 W > 10 5 > 10 5 > 10 6 > 10 6 > 5 x 10 6 > 5 x 10 7 AC: o C AC: o C AC: o C AC: o C DC: o C DC: o C DC: o C DC: o C oz ( g) oz ( g) oz ( g) 7.1 oz (200 g) IP 00 min: 4000 V AC typ.: 5000 V AC 8000 V AC 15 / 12 ms 15 / 12 ms 30 / 30 ms < 40 / < 20 ms

8 8 Automotive relays Type of relay DG19 DG85 DG34 ❶ Standard contact materials and coil / input control circuit rated voltages are marked with bold type. ❷ Between coil and contacts ❸ Clearance / creepage ❹ Version with cover ❺ Version without mounting flange ❻ PCB version ❼ SPST version only ❽ Version with resistor ❾ Not available on 80 A & 100 A ❿ IP 67 waterproof version At 230 V AC/DC; at 24 V AC/DC 0.3 VA / 0.3 W (L x W x H) 1.04 x 0.85 x 0.85 in ❹ 1.1 x 1.1 x 1 in ❺ 1.25 x 1.06 x 0.75 in ❻ 26.5 x 21.5 x 21.5 mm ❹ 28 x 28 x 25 ❺ 31.7 x 26.9 x 19.1 mm ❻ Contact data / Output data Number and type of contacts SPDT, SPST, SPST-NC SPDT, SPST, SPST-NC SPDT, SPST, SPST-NC Max. switching voltage current dependent current dependent 277 V AC / Rated current 100 A 80 A 60 A 40 A 30 A 20 A 10 A 45 A 30 A 60 A 80 A 100 A ❼ 30 A Contact material ❶ 10, 0.15, 10, AgCdO AgCdO, AgSnOInO AgCdO, AgSnOInO AgSnOInO Coil data / Input control circuit Rated voltage ❶ AC: V 50/60 Hz DC: V DC: V DC: V Rated power consumption AC: 2.0 VA DC: 1.5 W DC: 1.6 W (1.81 W ❽) DC: 1.0 W option: 0.9 W General data Electrical life (AC1) > 2 x 10 5 > 2 x A & 100 A: > 10 5 > 10 5 Mechanical life (cycles) > 10 7 > 10 7 > 10 7 Ambient temperature AC: o C operating DC: o C DC: o C DC: o C Weight open: 0.6 oz (18 g) 1.2 oz (35 g) open: 0.6 oz (20 g) covered: 0.8 oz (23 g) covered: 0.9 oz (25 g) Cover protection category IP 00 or IP 50 ❹ or IP 67 ❹❿ IP 50 or IP 67 ❾❿ IP 00 or IP 50 ❹ or IP 67 ❹❿ Recognitions, certifications, directives Insulation dielectric strength ❷ 500 V AC 500 V AC AC coil / DC coil: 1500 / Contact - coil distance ❸ 3 / 3 mm Operating / release time 5 / 3 ms 7 / 2 ms 15 / 15 ms Connection diagram: for other variations - see

9 Interface relays 9 DP6-1P DP6-1T DP6-OC 3.69 x 0.24 x 3.15 in 93.8 x 6.2 x 80 mm 3.69 x 0.24 x 3.15 in 93.8 x 6.2 x 80 mm Triac 3.69 x 0.24 x 3.15 in 93.8 x 6.2 x 80 mm Transistor Interconnection strips type DZG20 SPDT 250 V AC / 220 V DC 400 / / 70 6 A AgSnO 2 AgSnO2/Au 3 µm 1.2 A 0.5 A For interface relays type: DP6-1P, DP6-1T, DP6-OC AC: V 50/60 Hz DC: V AC/DC: V AC: 50/60 Hz DC: V AC/DC: V AC: 50/60 Hz DC: V AC/DC: V AC: 50/60 Hz DZG20-1: red color DZG20-2: black color DZG20-3: blue color AC: VA DC: W AC/DC: VA / W > 0.6 x A, 250 V AC > 2 x 10 7 DC: 0.3 W AC/DC: 1.6 VA / 1.6 W DC: 0.3 W AC/DC: 1.6 VA / 1.6 W Strip DZG20 Designed for bridging of common input / output signals terminated with appropriate spring contacts. Maximum current rating is 36 A (250 V). DC: o C 12, 24 V DC DC: o C DC: o C 1.4 oz (40 g) 1.4 oz (40 g) 1.4 oz (40 g) IP 20 IP 20 IP V AC AC: 7 / 15 ms, DC: 6 / 10 ms max 10 (zero turn-on) / max 10 ms DP6-1P SPDT, DC version DP6-1T, DC version DP6-OC, DC version

10 10 Plug-in sockets and accessories DZM80 For DM84, DM85, DM87L, DM87P 3.07 in (78.1) x 0.63 (15.9) x 2.4 in (61) [2.64 in (67)] Double pole 0.2 in (5 mm) pin layout 12 A, 300 V Connection diagrams DM84 DM85 ❶ DM87L DM87P DZM92 For DM87N, DM87N sensitive 3.07 in (78.1) x 0.63 (15.9) x 2.4 in (61) [2.64 in (67)] Single pole in (3.5 mm) pin layout 12 A, 300 V Accessories ❷ DZT Module type DM6.. DZT Connection diagram DZT Accessories ❷ DZT Module type DM6.. DZM2 For D in (75) x 1.06 (27) x 2.4 in (61) [3.23 in (82)] Double pole 12 A, 300 V Connection diagram DZT DG ❶ For DM85: loads up to 12 A do not require bridging of common terminals. Loads above 12 A require bridging pairs of terminals: 11 with 21, 12 with 22, 14 with 24 [clamp bridge Cu wire minimum 14 AWG (1.5 mm 2 )]. ❷ Signalling / protection modules type DM6.. - see page 5. ❸ DUC11 limits max switching voltage up to 250 V AC/DC and coil rated voltage up to 240 V AC. The height of sockets with retainer / retractor clip is shown in square brackets. Accessories ❷ DZT Module type DM6..

11 Plug-in sockets and accessories 11 DZM4 For D in (75) x 1.06 (27) x 2.4 in (61) [3.23 in (82)] Four pole 6 A, 300 V Connection diagram DZT DG DZ8 For D15 DPDT 2.68 in (68.2) x 1.5 (38) x 0.94 in (24.2) 10 A, 250 V Accessories ❷ DZT Module type DM6.. Connection diagram Accessories ❷ DZ DZ11 For D15 3PDT 2.68 in (68.2) x 1.5 (38) x 0.94 in (24.2) 10 A, 250 V Connection diagram Accessories ❷ DZ DUC11 ❸ For DUC 3.23 in (82) x 1.66 (42.2) x 1.04 in (26.5) 16 A, 250 V Connection diagram Accessories ❷ DMBA

12 12 Due to the constant development policy, American Electronic Components Inc. reserves the right to introduce changes to data and characteristics of the products. The devices shall be operated by skilled personnel in accordance with the regulations in force pertaining to electrical systems. The technical data is of informational nature. Thus, American Electronic Components Inc. does not accept any liability for inappropriate use of the presented products. Durakool and American Electronic Components Inc., specializes in the design and manufacture of electronic, electrical, and mechanical components. AEC s products are shipped worldwide for a diverse set of markets which include automotive, consumer electronics, appliance, industrial control and outdoor power equipment manufacturers. For more information, contact the AEC Sales Department toll free (USA) Products from American Electronic Components Inc. and Durakool: Mercury Contactors sub-miniature relays miniature relays industrial relays interface relays plug-in sockets for relays contactors timer relays mercury contactors tilt switches tip-over switches float switches liquid level switches hermetic seals, feed throughs and sight glasses Tilt and Tip-over Switches Hermetic Seals presented by: 07/2006 American Electronic Components Inc., 1101 Lafayette Street, Elkhart, Indiana IN Tel: toll free (USA) Intl

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

Electromechanical Relays

Electromechanical Relays Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern technology ensures high

More information

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A 72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature

More information

10 SERIES. Light dependent relays A

10 SERIES. Light dependent relays A 10 SERES 10 SERES Relays for automatic control of lighting according to the ambient light level ntegral light sensor For pole or wall mounting 10.32-2 O 16 A output contacts 10.41-1 O 16 A output contact

More information

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet , 2, 3 or 4 pole, 7-12 A Datasheet Features Compact plug-in design 2, 3 or 4 C/O contacts Standard mechanical indicator Flat and silver relay pins for excellent connection in socket Wide range sockets

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

Electromechanical Relays

Electromechanical Relays Electromechanical Relays Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern

More information

Interface Relays and Optocouplers Product group picture

Interface Relays and Optocouplers Product group picture Interface Relays and Optocouplers Product group picture /1 ABB Catalog 2CDC 1 004 C0208 Interface Relays and Optocouplers Table of contents Interface Relays and Optocouplers Interface Relays and Optocouplers

More information

Type Contact form Model

Type Contact form Model Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted

More information

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay LoopBack Relay SGLB363 Series With Built-in AC Bypass Capacitors / DC LoopBack Relay SERIES DESIGNATION SGLB363 RELAY TYPE LoopBack Relay, Sensitive Coil, Surface Mount Ground Shield and J-Leads with AC

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled CE CPS 12/15 W ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

Pluggable interface relays CR-M Miniature relays

Pluggable interface relays CR-M Miniature relays 2CDC 293 035 F0004 CR-M 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply voltages: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions:

More information

Pluggable interface relays CR-M Miniature relays

Pluggable interface relays CR-M Miniature relays 2CDC 293 035 F0004 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply s: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V,

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.

More information

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SERIES SGRF300 SGRF300D SGRF300DD SGRF303 SGRF303D SGRF303DD RELAY TYPE Repeatable, RF relay Repeatable, RF relay with internal diode for coil

More information

Pulse Counters, electromechanical

Pulse Counters, electromechanical Mini Counters W 5 / AW 5 5-digit miniature pulse counter, adding with manual reset Power consumption min. 30 mw Suitable for battery and electronic switching operations Long operating life (50 Mio. pulses)

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Magnecraft Power Relays. Catalog

Magnecraft Power Relays. Catalog Magnecraft Power Relays Catalog 2015 Contents bbseries Overview....................................................3 bb199 Series Relays..................................................4 bb725 Series

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

relays industrial relays interface relays installation relays miniature relays subminiature signal relays time relays plug-in sockets and accessories

relays industrial relays interface relays installation relays miniature relays subminiature signal relays time relays plug-in sockets and accessories relays industrial relays interface relays installation relays miniature relays subminiature signal relays time relays 2011 plug-in sockets and accessories 1 Export Sales Department e-mail: export@relpol.com.pl

More information

90 Series - Sockets and accessories for 60 series relays

90 Series - Sockets and accessories for 60 series relays 90.0 olour BLUE BLAK BLUE BLAK lamp terminal socket: panel or mm rail (EN 00) mount 90.0 90.0.0 90.0 90.0.0 Identification tag 090.00. Modules (see table below) 99.0 Timer module (see table below).00,.0,.0

More information

02/11/2015

02/11/2015 24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

Relays. for industry.

Relays. for industry. Relays for industry 2015 2016 Relays for industry FASTON 187 2 industrial relays general control of electrical equipment, industrial control systems, equipment for air-conditioning, refrigeration products,

More information

MILLITARY SPECIFICATION SHEET

MILLITARY SPECIFICATION SHEET INCH-POUND MILLITARY SPECIFICATION SHEET 10 November 2000 SUPERSEDING MIL-R-6106/14B 10 March 1989 RELAY, ELECTRIC, PERMANENT DRIVE, 50 AMP, SPDT (DB) DOUBLE MAKE DOUBLE BREAK AUXILIARY CONTACTS (5 AMP),

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled E 15 W CE CPS ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC

More information

Definite Purpose Contactors

Definite Purpose Contactors Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 40W 900mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 50,000

More information

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SERIES SRF00 SRF00D SRF00DD SRF0 SRF0D SRF0DD RELAY TYPE Repeatable, RF relay Repeatable, RF relay with internal diode for coil transient suppression

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

s w i t c h i n g c o n t r o l l i n g c o u n t i n g s w i t c h i n g c o n t r o l l i n g c o u n t i n g S A V E T I M E I L L U M I N A T E S A V E E N E R G Y C O N N E C T F E E L W E L L A C C E S S O R I E S 2 014 switching controlling counting

More information

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 30,000 h For luminaires of protection class I and protection

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000

More information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated

More information

Bill of Materials: Super Simple Water Level Control PART NO

Bill of Materials: Super Simple Water Level Control PART NO Super Simple Water Level Control PART NO. 2169109 Design a simple water controller in which electrodes are required to sense high and low water levels in a tank. Whenever the water level falls below the

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver.   Product description. Benefits. Interfaces. Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Warner Photoscanner MCS-500 Series LED Photoelectric Control Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow controls VFC Linear flow controls with actuator IFC Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or

More information

15 Series - Dimmer

15 Series - Dimmer Features Master slave system for multiple load dimming Suitable for incandescent and halogen lighting loads (with or without transformer or electronic supply) Compatible with energy saving (CF or ED) dimmable

More information

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The

More information

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/ Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable

More information

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver.   Product description. Benefits. Interfaces. Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LED control gear Compact fixed output

LED control gear Compact fixed output Driver LC 40W 900mA fixc SR SNC ESSENCE series Product description Independent fixed output LED Driver Constant current LED Driver Output current 900 ma Max. output power 39 W Nominal life-time up to 50,000

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

D-B relay - High DC breaking capacity, Datasheet

D-B relay - High DC breaking capacity, Datasheet - High DC breaking capacity, Datasheet power relay, 4 pole Features Compact plug-in design Instantaneous, 4 C/O contacts High DC breaking capacity LED indicator Back EMF suppression diode (DC versions)

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5 SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display DSM7UA20105-0.20 (5.08mm) Digit Height Emitting Color: Pure Green (InGaN/GaN) Applications People Movers Home Appliances Medical Devices

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

1900/25 Vibration Monitor

1900/25 Vibration Monitor 1900/25 Vibration Monitor BENTLY NEVADA MADE IN USA VIBRATION MONITOR OK ALERT DANGER BYPASS DISPLAY MOD E RESET NORMAL ALERT ALERT ADJUST LEVEL DANGER DANGER LEVEL ADJUST BUFFER ED TRANSDUCER 1 IN/SEC

More information

POINTS POSITION INDICATOR PPI4

POINTS POSITION INDICATOR PPI4 POINTS POSITION INDICATOR PPI4 Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding led on a control panel to show the last operation of each

More information

FOM-9010, FOM-9011 and FOM-9012

FOM-9010, FOM-9011 and FOM-9012 Control and Alarm Voltage sense, open collector, or contact inputs Features: FOM-00: Voltage Sense, Open Collector, or Dry Contact Inputs. State Detection for TIA-, TIA-, and TTL Signals. FOM-0: SPDT Form

More information

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm 21.610/1 RAK: Universal thermostat How energy efficiency is improved Demand-led controlling, monitoring and limiting, without auxiliary energy. Areas of application For controlling and monitoring the temperature

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ø22mm - W Series Oiltight W Series Switches and Pilot Devices: 22mm W Series offer flexibility in space-saving package Key features include: P board mount, solder or screw terminal ollective mounting saves

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information