1 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN) produced according to ISO 9001: 2000 Ver. 0.2/ Art.-Nr.: E 1 / 8

2 7-Segment Double Digit Indicator (CAN) Contents: 1. Introduction Connection Mechanic CAN-Bus Interface Addresses Baud rate CAN-Communication CAN Telegram CAN command structure: CAN answer structure CAN-Commands Pseudo commands (2 [=02Hex]) Delete display (4 [=04Hex]) Number which should light (6 [=06Hex]) Number which should blink [Frequency: 1 Hz] (8 [=08Hex]) Service Decommissioning Product labels Technical data Introduction The 7-Segment display may serve to visualize the position of parts within an automatic storage system. Controlling the dual digit display is done through use of the CAN-Bus. Depending on the command, the display can be continuous or blinking. Also various intensity levels for the display may be selected. Various Addresses and Baudrates are available and may be selected for operation within the CAN-Bus. 2. Connection On the back side of the controller, three connectors may be found. Two RJ45 connectors and one terminal block may be found here. Table 1 Designation Type 1 CAN RJ45 2 CAN RJ45 3 Supply (ground, 0V, 24V) Terminals The supply voltage is connected to the controller as shown on the terminal block (Nr. 3) Figure 1: 7-Segment display and controller Figure 2: Terminal designation Ver. 0.2/ Art. Nr E Seite 2

3 7-Segment Double Digit Indicator (CAN) The integration into a CAN-Bus system is made possible by using both RJ45 connectors. 3. Mechanic The dimensions of the 7-Segment display may be seen in figure Figure 3: Dimensions of the housing The dimensions necessary for mounting the 7- Segment display in a machine frame may be seen in figure min 1.5 Figure 4: Dimensions of the mounting slot 4. CAN-Bus Interface The pins of both RJ45 CAN-Interfaces are occupied according to the general CAN-Definition as follows: Table 2: RJ45 pin Connection 1 CAN High 2 CAN Low 3 CAN Ground CAN Shield 7 CAN Ground 8 CAN +24 V The CAN-Bus interface does not have an integrated galvanic voltage supply for the CAN-Bus portion. This means that when connecting to a CAN-Bus system, next to CAN-High, and CAN- Low, the pins 3, 6, 7, and 8, must also be used. Through use of the Dip- at the house opening, the Address (4.1.1) and the Baud-Rate (4.1.2) may be set. Note: Before starting operation, it is very important to double check the Address setting of the controller. Each Address may only be used once per network! A 7-Segment display is CAN capable and with a few limitations may also be integrated into a CANopen system. Ver. 0.2/ Art. Nr E Seite 3

4 7-Segment Double Digit Indicator (CAN) Addresses Through the use of 4 Dip-es, 16 different node addresses may be configured. Receiver-Identifier for 7-Segment display: 0x230 + Node address (=0x230, 0x231,..., 0x23F) Emitter-Identifier for 7-Segment display: 0x1B0 + Node address (=0x1B0, 0x1B1,..., 0x1BF) Table 3: Offset to Address off off off off off 1 off off off on off 2 off off on off off 3 off off on on off 4 off on off off off 5 off on off on off 6 off on on off off 7 off on on on off 8 on off off off off 9 on off off on off 10 on off on off off 11 on off on on off 12 on on off off off 13 on on off on off 14 on on on off off 15 on on on on off Baud rate Through the use of 2 additional Dip-switches the Bit rate may be adjusted (125/250/500/1000 kbit/s) Table 4: Baud rate k off off 250 k off on 500 k on off 1 M on on Ver. 0.2/ Art. Nr E Seite 4

5 7-Segment Double Digit Indicator (CAN) 5. CAN-Communication 5.1. CAN Telegram CAN command structure: Commands that are sent to the controller over the CAN-Bus must be built up as follows (message length: 8 Bytes each): Command Data Byte The following commands are possible: Command 2 Byte Command: 2: Pseudo command PLC 4: Delete number 6: Number which should light 8: Number which should blink Data 6 Byte Data, which must be transmitted with a command (see chapter 6) Telegram length 8 Byte Example for command 4 [=04Hex]: Byte Byte 1 Byte 2 Byte 3-8 Bits Value CAN answer structure Answers from a 7-Segment controller are built up as follows: Answer to command Data Byte The answer telegram from a 7-Segment controller is attached an offset of +1 (compared to the command). Ver. 0.2/ Art. Nr E Seite 5

6 7-Segment Double Digit Indicator (CAN) Answer to command (command Nr. + 1) Byte 1+2 Answer Answer n+1 to command n : 3 03Hex Sends pseudo answer 5 05Hex Sends confirmation 7 07Hex Sends confirmation 9 09Hex Sends confirmation Data Byte 3-8 Data, which can be given with an answer (see chapter 6) Telegram length 8 Byte 6. CAN-Commands Basically all command numbers are even, and answers are odd Pseudo commands (2 [=02Hex]) The Pseudo-command serves merely to allow the 7-Segment display controller to respond to the PLC over the first emitter identifier. Command 2 [=02Hex] Answer 3 [=03Hex] Bit Delete display (4 [=04Hex]) With this command, both of the 7-Segment display digits will be turned off. Command 4 [=04Hex] Answer 5 [=05Hex] Bit Number which should light (6 [=06Hex]) Byte 3 Byte 4 Byte 5 Byte 6 8 Command 6 [=06Hex] 0-7: Left 7-Segment display (0 9: number 10: no display) 0-7: Right 7-Segment display (0 9: number 10: no display) 0-7: Intensity (0= Maximum, 1, 2, 3= Minimum) Answer 7 [=07Hex] Bit Ver. 0.2/ Art. Nr E Seite 6

7 7-Segment Double Digit Indicator (CAN) Number which should blink [Frequency: 1 Hz] (8 [=08Hex]) Byte 3 Byte 4 Byte 5 Byte 6 8 Command 8 [=08Hex] 0-7: Left 7-Segment display (0 9: Number 10: no display) 0-7: Right 7-Segment display (0 9: Number 10: no display) 0-7: Intensity (0= Maximum, 1, 2, 3= Minimum) Answer 9 [=09Hex] Bit Ver. 0.2/ Art. Nr E Seite 7

8 7-Segment Double Digit Indicator (CAN) 7. Service The 7-Segment displays are built electronically and do not need preventative maintenance Decommissioning If a 7-Segment display must be disposed of, it may be simply dismantled, and the materials sorted according to state of the art technology and according to local regulations recycled. 8. Product labels Figure 5 shows an example of the product label which is attached to each 7-Segment display. 9. Technical data General data Nominal working type Temperature range Enclosure rating according to EN Housing Terminals Conductor connection: 3-pin terminal strip (plug-in) Mounting Net weight Equipment dimensions Continuous process Operating temp.: C Stock temp.: C IP20 IP20 Wire cross-section: 1.7 mm (max) (2.27 mm 2 ) Terminal screw thread: M2 Both side snap mounting as shown in chapter 3 80 g 72x24x82,5 mm Inputs Voltage U N at 5% residual ripple Nominal use Device protection (external) 24 VDC U N 40mA 2 A Figure 5: Product label 7-Segment display Explanation of terminology: Table 5 Ser. no HW SW Prod.-Date YYMMDD/ Order confirmation number/ Code final inspection Hardware Version Software Version Ver. 0.2/ Art. Nr E Seite 8

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION The Eltra multiturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard

More information

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface O P E R A T I O N M A N U A L Version 01/05 RF-Reader Stand-alone-Reader Leser 2plus with RS-232 interface Important! Read by all means! To maintain the perfect shipping conditions and to ensure safe operation

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

User Manual DVM-HDBT-EX3

User Manual DVM-HDBT-EX3 User Manual DVM-HDBT-EX3 HD-BaseT-Extender HDMI+2xIR+RS232 100m Seite 1 von 13 NOTICE: Please read this user manual carefully before using this product. This manual is only for operation instruction only,

More information

PT9232. Heavy Industrial RS232 Communication

PT9232. Heavy Industrial RS232 Communication PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection Hazardous

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION The Eltra singleturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution

More information

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136 KNX / EIB Product Documentation DALI Gateway Date of issue: 13.03.2008 64540122.12 Order no. 7571 00 03 Page 1 of 136 KNX / EIB Product Documentation Table of Contents 1 Product definition... 3 1.1 Product

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Users guide for PB units Interface unit, 4- or 6-digit

Users guide for PB units Interface unit, 4- or 6-digit Users guide for PB units Interface unit, 4- or 6-digit P s P Nm Status 12/2015 / PBXABXGB.doc Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper use... 3 2.2. Control of the device...

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians Radio receiver EXL 4-channel / up to 1000 memory locations Mounting and operating instructions for qualified electricians Please keep these instructions so that you have them available if you have any

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER. Multiturn ABSOLUTE ENCODERS. Presentation. Hardware installation device

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER. Multiturn ABSOLUTE ENCODERS. Presentation. Hardware installation device Presentation EAM PROFIBUS MULTITURN ABSOLUTE ENCODER The Eltra multiturn Profi bus encoder series (Identifi cation Number 0x0599) is complying to the Profi bus DP standard as described on the European

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

PT9232. Heavy Industrial RS232 Communication

PT9232. Heavy Industrial RS232 Communication PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection GENERL

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines

More information

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio Heading AC180A 8 Input x 8 Output Composite Video Matrix Switch with Audio MARCH 2005 AC180A AC182A AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio CUSTOMER SUPPORT INFORMATION Order toll-free

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

User Manual POE. Twisted Pair POE Extender

User Manual POE. Twisted Pair POE Extender User Manual 77451-POE Twisted Pair POE Extender SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice. 1. Introduction 1.1 Overview The RFL VS800 CODEC enables high quality video transmission combined with voice and data over E1 (2.048Mbit/s), T1 (1.55Mbit/s) or Ethernet links. This provides an alternative

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Hardware & software Specifications

Hardware & software Specifications Hardware & software Specifications Réf : PRELIMINARY JUNE 2007 Page 2 of 17 1. PRODUCT OVERVIEW...3 2. TERMINOLOGY...4 A. THE FRONT PANEL...4 B. THE REAR PANEL...5 3. SCREENS DESCRIPTION...5 A. MAIN SCREEN

More information

CAT5 VGA Extender. Mode 1 Mode 2

CAT5 VGA Extender. Mode 1 Mode 2 ITEM NO.: TTP111VGA CAT5 VGA Extender The VGA Extender allows VGA video signals to be transmitted up to 135 meters via 4-paris CAT5 STP or UTP cable. Used in pairs, the VGA Extender is used in home or

More information

Site Installation Model MP-8424

Site Installation Model MP-8424 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS UNI EN ISO 9001 C R US MULTITURN SOLUTE ENCODER PROFIUS Presentation The ELTR Profibus multi-turn encoder (Identification Number 0x0599) conforms to the Profibus DP standard, described by European Standard

More information

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8 Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between

More information

Extra long-range RFID (proximity) card reader

Extra long-range RFID (proximity) card reader GP90A Extra long-range RFID (proximity) card reader (1) Features: Extra long reading range of up to 90 cm with ISO-size passive RFID cards*, over 100 cm with special optimized passive cards High-precision

More information

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

Electrical connection

Electrical connection Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

2070 PROFINET MODULE

2070 PROFINET MODULE Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 2070 PROFINET MODULE Status and weight transfer using PROFINET Applies for: Software: CONCTR_4.160530.1v0

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

I N S T R U C T I O N D A T A

I N S T R U C T I O N D A T A I N S T R U C T I O N D A T A RFL (C37.94) Fiber Service Unit Single Mode 108015-1 RS-449 108015-2 V.35 108015-3 G.703 108015-4 X.21 108015-5 E1 Multimode 107460-1 RS-449 107460-2 V.35 107460-3 G.703 107460-4

More information

Single mode 9/125µm, duplex

Single mode 9/125µm, duplex Fiber Converter Module RS-232 MICROSENS General For the connection of devices, control units and machine controls with standard serial interfaces MICROSENS is offering special fiber converters for the

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender This product has been replaced by the HD-EXT4-C. The Crestron HDMI over Shielded Twisted Pair Extender (HD- EXT2-C) delivers professional-grade digital HD AV signal extension for use in a boardroom, classroom,

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.

More information

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,

More information

Proportional output thumbwheels - sprung to centre

Proportional output thumbwheels - sprung to centre New! HR series Distinctive features and specifications High reliability, long life HR-A-R Sealed to IP68 Backlighting option EMI/RFI shielding Other detent options on request Patented solution ENVIRONMENTAL

More information

Site Installation Model MP-8433

Site Installation Model MP-8433 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The

More information

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs) USER MANUAL MODEL 460RC Rack-Mounted G.70 Coax to Twisted Pair Adapters (BALUNs) An ISO-900 Certified Company Part # 07M460RC-A Doc. #0908UA Revised //98 SALES OFFICE (0) 975-000 TECHNICAL SUPPORT (0)

More information

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0 Advantys STB Standard Profibus DP Network Interface Module Applications Guide 890USE17300 Version 2.0 31002957 01 31002957 01 2 Table of Contents Safety Information....................................

More information

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features:

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features: DRAW WIRE SENSOR Series MH120 for mobile hydraulics applications Key-Features: Content: Introduction...2 Technical data...3 Analog outputs...3 Digital output CANopen...4 Electrical connection...4 Technical

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output SSI-1016G Manual Caution: Specifications and outline may be changed without notice MTS Sensors Technology Corporation www.mtssensor.co.jp 2010.02.04 Rev. 1 1 Revision information 2007.03.12: Data-ready

More information

MAXX BOX. MX102/202 Series. MAXX Box

MAXX BOX. MX102/202 Series. MAXX Box MX102/202 Series MAXX Box MAXX BOX 1 C O N T E N T S SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical... 5 Physical...

More information

Multiple Band Outdoor Block Up- and Downconverters

Multiple Band Outdoor Block Up- and Downconverters Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625

More information

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Contents Page 1.0 Overview... 3 2.0 Installation.. 4 2.1 Electrical connections... 4 2.2 Cable selection... 4 2.3 Electrical

More information

SERCOS TSX CSY 84 Module V

SERCOS TSX CSY 84 Module V SERCOS TSX CSY 84 Module V At a Glance Aim of this Part What's in this part? This part presents the SERCOS TSX CSY 84 module, its operating features and its installation. This Part contains the following

More information

VIPA Accessories. ProfiHub B BE00 Manual

VIPA Accessories. ProfiHub B BE00 Manual VIPA Accessories ProfiHub B5 973-5BE00 Manual HB151E Rev. 12/04 January 2012 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

4-DIGIT & 6-DIGIT "U" SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL

4-DIGIT & 6-DIGIT U SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL 142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com 4-DIGIT & 6-DIGIT "U" SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL The "U" Series of 4-digit and 6-digit

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

4040C COMMUNICATION MODULE

4040C COMMUNICATION MODULE Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 4040C COMMUNICATION MODULE BIN communication in a 4x40C system Applies for: Program no.: BIN_1LC.130307.0

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

S6-R READER. Installation and Operating Instructions

S6-R READER. Installation and Operating Instructions Installation and Operating Instructions The information provided in these installation instructions may be modified without prior notification. All previous versions cease to be valid with the publication

More information

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS ISO 9001:2000 C R US MULTITURN SOLUTE ENCODER EM PROFIUS Presentation The Eltra multi-rotation Profibus encoder (Identification Number 0x0599) conforms to the standard Profibus DP described in the European

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

Hex-color RGBAW+UV LED strip light

Hex-color RGBAW+UV LED strip light Hex-color RGBAW+UV LED strip light 2 19 SAFETY / GENERAL INSTRUCTIONS INTRODUCTION Features Specifications OVERVIEW : CONNECTIONS Rear view DIMENSIONS INSTALLATION Mounting FUNCTIONS AND SETTINGS Function

More information

USER MANUAL HDMI over IP EXTENDER

USER MANUAL HDMI over IP EXTENDER USER MANUAL HDMI over IP EXTENDER Introduction: The HDMIRHRX101120M is a sophisticated many to many HDMI over IP extender. HDCP 2.0 compliant and resolutions up to 1080P full HD and 1920x1200 (WUXGA) are

More information

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! www.signaltransformer.com Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! Audio Battery Chargers Communication Dental Equipment Elevator Controls Fire & Safety

More information

USER MANUAL. DS Vision Digital HD Digital Distribution System MODEL: P/N: Rev 2

USER MANUAL. DS Vision Digital HD Digital Distribution System MODEL: P/N: Rev 2 USER MANUAL MODEL: DS Vision Digital HD Digital Distribution System P/N: 2900-300283 Rev 2 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions 3 2.3

More information

LCS 2 RJ 45 Cat. 6A HD panels and units

LCS 2 RJ 45 Cat. 6A HD panels and units 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1

More information

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15

More information

FLEXIBLE SERIES DA LR WW LENTUS

FLEXIBLE SERIES DA LR WW LENTUS Technical Information is an ideal solution which can be used easily for limited areas or thin spaces because of its minimalist design of 1cm, flexible body structure and sticky band feature found behind..

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4 last edited: 2014-08-12 OPERATING MANUAL DMX512 to DALI Dekoder 7044A-H Mk4 (C) SOUNDLIGHT 1996-2015 * ALL RIGHTS RESERVED * NO PART OF THIS MANUAL MAY BE REPRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT

More information

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL EXTENDER B-540-EXT-230-RS INSTALLATI MANUAL IMPORTANT SAFETY INSTRUCTIS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this manual. Keep this manual for

More information

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System - 1 - Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System The DPC 4 welding system offers several features that are intended to communicate with automation. These features

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

DIGI-BSR-4K Installation Guide

DIGI-BSR-4K Installation Guide DIGI-BSR-4K Installation Guide Scaler Status HDCP Link Firmware L R TX RX 12V DC Ethernet1 Ethernet2 HDBT In IR In IR Out HDMI Out S/PDIF Out Audio Out RS232 The Intelix DIGI-BSR-4K extends HDMI over a

More information