CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)
|
|
- Noel Dorsey
- 6 years ago
- Views:
Transcription
1 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN) produced according to ISO 9001: 2000 Ver. 0.2/ Art.-Nr.: E 1 / 8
2 7-Segment Double Digit Indicator (CAN) Contents: 1. Introduction Connection Mechanic CAN-Bus Interface Addresses Baud rate CAN-Communication CAN Telegram CAN command structure: CAN answer structure CAN-Commands Pseudo commands (2 [=02Hex]) Delete display (4 [=04Hex]) Number which should light (6 [=06Hex]) Number which should blink [Frequency: 1 Hz] (8 [=08Hex]) Service Decommissioning Product labels Technical data Introduction The 7-Segment display may serve to visualize the position of parts within an automatic storage system. Controlling the dual digit display is done through use of the CAN-Bus. Depending on the command, the display can be continuous or blinking. Also various intensity levels for the display may be selected. Various Addresses and Baudrates are available and may be selected for operation within the CAN-Bus. 2. Connection On the back side of the controller, three connectors may be found. Two RJ45 connectors and one terminal block may be found here. Table 1 Designation Type 1 CAN RJ45 2 CAN RJ45 3 Supply (ground, 0V, 24V) Terminals The supply voltage is connected to the controller as shown on the terminal block (Nr. 3) Figure 1: 7-Segment display and controller Figure 2: Terminal designation Ver. 0.2/ Art. Nr E Seite 2
3 7-Segment Double Digit Indicator (CAN) The integration into a CAN-Bus system is made possible by using both RJ45 connectors. 3. Mechanic The dimensions of the 7-Segment display may be seen in figure Figure 3: Dimensions of the housing The dimensions necessary for mounting the 7- Segment display in a machine frame may be seen in figure min 1.5 Figure 4: Dimensions of the mounting slot 4. CAN-Bus Interface The pins of both RJ45 CAN-Interfaces are occupied according to the general CAN-Definition as follows: Table 2: RJ45 pin Connection 1 CAN High 2 CAN Low 3 CAN Ground CAN Shield 7 CAN Ground 8 CAN +24 V The CAN-Bus interface does not have an integrated galvanic voltage supply for the CAN-Bus portion. This means that when connecting to a CAN-Bus system, next to CAN-High, and CAN- Low, the pins 3, 6, 7, and 8, must also be used. Through use of the Dip- at the house opening, the Address (4.1.1) and the Baud-Rate (4.1.2) may be set. Note: Before starting operation, it is very important to double check the Address setting of the controller. Each Address may only be used once per network! A 7-Segment display is CAN capable and with a few limitations may also be integrated into a CANopen system. Ver. 0.2/ Art. Nr E Seite 3
4 7-Segment Double Digit Indicator (CAN) Addresses Through the use of 4 Dip-es, 16 different node addresses may be configured. Receiver-Identifier for 7-Segment display: 0x230 + Node address (=0x230, 0x231,..., 0x23F) Emitter-Identifier for 7-Segment display: 0x1B0 + Node address (=0x1B0, 0x1B1,..., 0x1BF) Table 3: Offset to Address off off off off off 1 off off off on off 2 off off on off off 3 off off on on off 4 off on off off off 5 off on off on off 6 off on on off off 7 off on on on off 8 on off off off off 9 on off off on off 10 on off on off off 11 on off on on off 12 on on off off off 13 on on off on off 14 on on on off off 15 on on on on off Baud rate Through the use of 2 additional Dip-switches the Bit rate may be adjusted (125/250/500/1000 kbit/s) Table 4: Baud rate k off off 250 k off on 500 k on off 1 M on on Ver. 0.2/ Art. Nr E Seite 4
5 7-Segment Double Digit Indicator (CAN) 5. CAN-Communication 5.1. CAN Telegram CAN command structure: Commands that are sent to the controller over the CAN-Bus must be built up as follows (message length: 8 Bytes each): Command Data Byte The following commands are possible: Command 2 Byte Command: 2: Pseudo command PLC 4: Delete number 6: Number which should light 8: Number which should blink Data 6 Byte Data, which must be transmitted with a command (see chapter 6) Telegram length 8 Byte Example for command 4 [=04Hex]: Byte Byte 1 Byte 2 Byte 3-8 Bits Value CAN answer structure Answers from a 7-Segment controller are built up as follows: Answer to command Data Byte The answer telegram from a 7-Segment controller is attached an offset of +1 (compared to the command). Ver. 0.2/ Art. Nr E Seite 5
6 7-Segment Double Digit Indicator (CAN) Answer to command (command Nr. + 1) Byte 1+2 Answer Answer n+1 to command n : 3 03Hex Sends pseudo answer 5 05Hex Sends confirmation 7 07Hex Sends confirmation 9 09Hex Sends confirmation Data Byte 3-8 Data, which can be given with an answer (see chapter 6) Telegram length 8 Byte 6. CAN-Commands Basically all command numbers are even, and answers are odd Pseudo commands (2 [=02Hex]) The Pseudo-command serves merely to allow the 7-Segment display controller to respond to the PLC over the first emitter identifier. Command 2 [=02Hex] Answer 3 [=03Hex] Bit Delete display (4 [=04Hex]) With this command, both of the 7-Segment display digits will be turned off. Command 4 [=04Hex] Answer 5 [=05Hex] Bit Number which should light (6 [=06Hex]) Byte 3 Byte 4 Byte 5 Byte 6 8 Command 6 [=06Hex] 0-7: Left 7-Segment display (0 9: number 10: no display) 0-7: Right 7-Segment display (0 9: number 10: no display) 0-7: Intensity (0= Maximum, 1, 2, 3= Minimum) Answer 7 [=07Hex] Bit Ver. 0.2/ Art. Nr E Seite 6
7 7-Segment Double Digit Indicator (CAN) Number which should blink [Frequency: 1 Hz] (8 [=08Hex]) Byte 3 Byte 4 Byte 5 Byte 6 8 Command 8 [=08Hex] 0-7: Left 7-Segment display (0 9: Number 10: no display) 0-7: Right 7-Segment display (0 9: Number 10: no display) 0-7: Intensity (0= Maximum, 1, 2, 3= Minimum) Answer 9 [=09Hex] Bit Ver. 0.2/ Art. Nr E Seite 7
8 7-Segment Double Digit Indicator (CAN) 7. Service The 7-Segment displays are built electronically and do not need preventative maintenance Decommissioning If a 7-Segment display must be disposed of, it may be simply dismantled, and the materials sorted according to state of the art technology and according to local regulations recycled. 8. Product labels Figure 5 shows an example of the product label which is attached to each 7-Segment display. 9. Technical data General data Nominal working type Temperature range Enclosure rating according to EN Housing Terminals Conductor connection: 3-pin terminal strip (plug-in) Mounting Net weight Equipment dimensions Continuous process Operating temp.: C Stock temp.: C IP20 IP20 Wire cross-section: 1.7 mm (max) (2.27 mm 2 ) Terminal screw thread: M2 Both side snap mounting as shown in chapter 3 80 g 72x24x82,5 mm Inputs Voltage U N at 5% residual ripple Nominal use Device protection (external) 24 VDC U N 40mA 2 A Figure 5: Product label 7-Segment display Explanation of terminology: Table 5 Ser. no HW SW Prod.-Date YYMMDD/ Order confirmation number/ Code final inspection Hardware Version Software Version Ver. 0.2/ Art. Nr E Seite 8
MBUS 10 RS232 TO MBUS LEVEL CONVERTER
Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit
More information48x24. Options ORDER NUMBER OF TYPE PFL B
Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid
More informationEAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS
EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION The Eltra multiturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard
More informationO P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface
O P E R A T I O N M A N U A L Version 01/05 RF-Reader Stand-alone-Reader Leser 2plus with RS-232 interface Important! Read by all means! To maintain the perfect shipping conditions and to ensure safe operation
More informationDATA SHEET Panorama Rudder Indicator, TRI-2
DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationBL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationUser Manual DVM-HDBT-EX3
User Manual DVM-HDBT-EX3 HD-BaseT-Extender HDMI+2xIR+RS232 100m Seite 1 von 13 NOTICE: Please read this user manual carefully before using this product. This manual is only for operation instruction only,
More informationPT9232. Heavy Industrial RS232 Communication
PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection Hazardous
More informationMS2540 Current Loop Receiver with RS485 Communication
MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:
More informationEA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS
EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION The Eltra singleturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard
More informationAbsolute encoders multiturn
The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution
More informationKNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136
KNX / EIB Product Documentation DALI Gateway Date of issue: 13.03.2008 64540122.12 Order no. 7571 00 03 Page 1 of 136 KNX / EIB Product Documentation Table of Contents 1 Product definition... 3 1.1 Product
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationUsers guide for PB units Interface unit, 4- or 6-digit
Users guide for PB units Interface unit, 4- or 6-digit P s P Nm Status 12/2015 / PBXABXGB.doc Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper use... 3 2.2. Control of the device...
More informationZ-D-IN. RS485 Modbus Module 5 Digital Inputs
S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -
More informationRadio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians
Radio receiver EXL 4-channel / up to 1000 memory locations Mounting and operating instructions for qualified electricians Please keep these instructions so that you have them available if you have any
More informationODW-621. RS-232 Point-to-point applications
Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to
More informationEAM PROFIBUS MULTITURN ABSOLUTE ENCODER. Multiturn ABSOLUTE ENCODERS. Presentation. Hardware installation device
Presentation EAM PROFIBUS MULTITURN ABSOLUTE ENCODER The Eltra multiturn Profi bus encoder series (Identifi cation Number 0x0599) is complying to the Profi bus DP standard as described on the European
More informationR1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)
INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationPT9232. Heavy Industrial RS232 Communication
PT9232 Heavy Industrial RS232 Communication Linear Position/Velocity to 550 inches (1400 cm) luminum or Stainless Steel Enclosure Options VLS Option To Prevent FreeRelease amage IP68 NEM 6 Protection GENERL
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationOcean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff
Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines
More informationAC182A 8 Input x 8 Output S-Video Matrix Switch with Audio
Heading AC180A 8 Input x 8 Output Composite Video Matrix Switch with Audio MARCH 2005 AC180A AC182A AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio CUSTOMER SUPPORT INFORMATION Order toll-free
More informationElectronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,
Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationUser Manual POE. Twisted Pair POE Extender
User Manual 77451-POE Twisted Pair POE Extender SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationBecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.
1. Introduction 1.1 Overview The RFL VS800 CODEC enables high quality video transmission combined with voice and data over E1 (2.048Mbit/s), T1 (1.55Mbit/s) or Ethernet links. This provides an alternative
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200
More informationHardware & software Specifications
Hardware & software Specifications Réf : PRELIMINARY JUNE 2007 Page 2 of 17 1. PRODUCT OVERVIEW...3 2. TERMINOLOGY...4 A. THE FRONT PANEL...4 B. THE REAR PANEL...5 3. SCREENS DESCRIPTION...5 A. MAIN SCREEN
More informationCAT5 VGA Extender. Mode 1 Mode 2
ITEM NO.: TTP111VGA CAT5 VGA Extender The VGA Extender allows VGA video signals to be transmitted up to 135 meters via 4-paris CAT5 STP or UTP cable. Used in pairs, the VGA Extender is used in home or
More informationSite Installation Model MP-8424
Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local
More informationMULTITURN ABSOLUTE ENCODER EAM PROFIBUS
UNI EN ISO 9001 C R US MULTITURN SOLUTE ENCODER PROFIUS Presentation The ELTR Profibus multi-turn encoder (Identification Number 0x0599) conforms to the Profibus DP standard, described by European Standard
More informationSet for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8
Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between
More informationExtra long-range RFID (proximity) card reader
GP90A Extra long-range RFID (proximity) card reader (1) Features: Extra long reading range of up to 90 cm with ISO-size passive RFID cards*, over 100 cm with special optimized passive cards High-precision
More informationOcean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff
Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More informationZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features
Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page
More informationElectrical connection
Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in
More information2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES
EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,
More information2070 PROFINET MODULE
Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 2070 PROFINET MODULE Status and weight transfer using PROFINET Applies for: Software: CONCTR_4.160530.1v0
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationI N S T R U C T I O N D A T A
I N S T R U C T I O N D A T A RFL (C37.94) Fiber Service Unit Single Mode 108015-1 RS-449 108015-2 V.35 108015-3 G.703 108015-4 X.21 108015-5 E1 Multimode 107460-1 RS-449 107460-2 V.35 107460-3 G.703 107460-4
More informationSingle mode 9/125µm, duplex
Fiber Converter Module RS-232 MICROSENS General For the connection of devices, control units and machine controls with standard serial interfaces MICROSENS is offering special fiber converters for the
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationHD-EXT2-C. HDMI over Shielded Twisted Pair Extender
This product has been replaced by the HD-EXT4-C. The Crestron HDMI over Shielded Twisted Pair Extender (HD- EXT2-C) delivers professional-grade digital HD AV signal extension for use in a boardroom, classroom,
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More informationPACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB
September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.
More informationLED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES
pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,
More informationProportional output thumbwheels - sprung to centre
New! HR series Distinctive features and specifications High reliability, long life HR-A-R Sealed to IP68 Backlighting option EMI/RFI shielding Other detent options on request Patented solution ENVIRONMENTAL
More informationSite Installation Model MP-8433
Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local
More informationAdvantys STB DATA SHEET. Advantys STB Output Module. Description. Features
Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The
More informationUSER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)
USER MANUAL MODEL 460RC Rack-Mounted G.70 Coax to Twisted Pair Adapters (BALUNs) An ISO-900 Certified Company Part # 07M460RC-A Doc. #0908UA Revised //98 SALES OFFICE (0) 975-000 TECHNICAL SUPPORT (0)
More informationAdvantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0
Advantys STB Standard Profibus DP Network Interface Module Applications Guide 890USE17300 Version 2.0 31002957 01 31002957 01 2 Table of Contents Safety Information....................................
More informationDRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features:
DRAW WIRE SENSOR Series MH120 for mobile hydraulics applications Key-Features: Content: Introduction...2 Technical data...3 Analog outputs...3 Digital output CANopen...4 Electrical connection...4 Technical
More informationDATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.
Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features
More information1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output
SSI-1016G Manual Caution: Specifications and outline may be changed without notice MTS Sensors Technology Corporation www.mtssensor.co.jp 2010.02.04 Rev. 1 1 Revision information 2007.03.12: Data-ready
More informationMAXX BOX. MX102/202 Series. MAXX Box
MX102/202 Series MAXX Box MAXX BOX 1 C O N T E N T S SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical... 5 Physical...
More informationMultiple Band Outdoor Block Up- and Downconverters
Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625
More informationInstallation and Setting up Instructions for the 990 Signal Conditioning Instrument
Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Contents Page 1.0 Overview... 3 2.0 Installation.. 4 2.1 Electrical connections... 4 2.2 Cable selection... 4 2.3 Electrical
More informationSERCOS TSX CSY 84 Module V
SERCOS TSX CSY 84 Module V At a Glance Aim of this Part What's in this part? This part presents the SERCOS TSX CSY 84 module, its operating features and its installation. This Part contains the following
More informationVIPA Accessories. ProfiHub B BE00 Manual
VIPA Accessories ProfiHub B5 973-5BE00 Manual HB151E Rev. 12/04 January 2012 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed
More informationAC diagonal module Ø 200 mm
max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More information4-DIGIT & 6-DIGIT "U" SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL
142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com 4-DIGIT & 6-DIGIT "U" SERIES TIME CODE READERS OPERATION AND MAINTENANCE MANUAL The "U" Series of 4-digit and 6-digit
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More information4040C COMMUNICATION MODULE
Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 4040C COMMUNICATION MODULE BIN communication in a 4x40C system Applies for: Program no.: BIN_1LC.130307.0
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationS6-R READER. Installation and Operating Instructions
Installation and Operating Instructions The information provided in these installation instructions may be modified without prior notification. All previous versions cease to be valid with the publication
More informationMULTITURN ABSOLUTE ENCODER EAM PROFIBUS
ISO 9001:2000 C R US MULTITURN SOLUTE ENCODER EM PROFIUS Presentation The Eltra multi-rotation Profibus encoder (Identification Number 0x0599) conforms to the standard Profibus DP described in the European
More informationKramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher
Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in
More informationHex-color RGBAW+UV LED strip light
Hex-color RGBAW+UV LED strip light 2 19 SAFETY / GENERAL INSTRUCTIONS INTRODUCTION Features Specifications OVERVIEW : CONNECTIONS Rear view DIMENSIONS INSTALLATION Mounting FUNCTIONS AND SETTINGS Function
More informationUSER MANUAL HDMI over IP EXTENDER
USER MANUAL HDMI over IP EXTENDER Introduction: The HDMIRHRX101120M is a sophisticated many to many HDMI over IP extender. HDCP 2.0 compliant and resolutions up to 1080P full HD and 1920x1200 (WUXGA) are
More informationPower Transformers & High Frequency Magnetics Your one source for all your magnetics needs!
www.signaltransformer.com Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! Audio Battery Chargers Communication Dental Equipment Elevator Controls Fire & Safety
More informationUSER MANUAL. DS Vision Digital HD Digital Distribution System MODEL: P/N: Rev 2
USER MANUAL MODEL: DS Vision Digital HD Digital Distribution System P/N: 2900-300283 Rev 2 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions 3 2.3
More informationLCS 2 RJ 45 Cat. 6A HD panels and units
87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1
More informationContactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15
More informationFLEXIBLE SERIES DA LR WW LENTUS
Technical Information is an ideal solution which can be used easily for limited areas or thin spaces because of its minimalist design of 1cm, flexible body structure and sticky band feature found behind..
More informationSafety Light Curtains
4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent
More informationINSTALLATION MANUAL FT-FOTR-1VDE-ST-S
INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More informationOPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4
last edited: 2014-08-12 OPERATING MANUAL DMX512 to DALI Dekoder 7044A-H Mk4 (C) SOUNDLIGHT 1996-2015 * ALL RIGHTS RESERVED * NO PART OF THIS MANUAL MAY BE REPRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT
More informationHDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL
EXTENDER B-540-EXT-230-RS INSTALLATI MANUAL IMPORTANT SAFETY INSTRUCTIS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this manual. Keep this manual for
More informationAutomation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System
- 1 - Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System The DPC 4 welding system offers several features that are intended to communicate with automation. These features
More informationLD OEM/LD PDS/LD PeCo
LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class
More informationVorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)
Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationPOSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet
Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationDIGI-BSR-4K Installation Guide
DIGI-BSR-4K Installation Guide Scaler Status HDCP Link Firmware L R TX RX 12V DC Ethernet1 Ethernet2 HDBT In IR In IR Out HDMI Out S/PDIF Out Audio Out RS232 The Intelix DIGI-BSR-4K extends HDMI over a
More information