ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Size: px
Start display at page:

Download "ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features"

Transcription

1 Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page Features Cleaning / Smallest in the Industry! Air Particle Sensor for In-line Measurement A high-performance fan for external air suction enables constant measuring over long periods. Semiconductor laser and highsensitivity optical design in the sensing section enable measurement of 0.-µm particles. Laser beam Airflow Measurement Principle A semiconductor laser beam is targeted on to the air intake and the light is scattered when particles pass through that beam. The scattered light is received by the light receiving element and converted to an electrical signal. Particle Trend Indicator The sensing section has a particle trend display for quick visual confirmation of the degree of cleanliness. The Amplifier provides numeric indication of the number of 0.-, 0.5-, and 1.0- Particle Numeric Display Particle Trend Display µm particles. A signal can be output at any level of particles if a threshold has been set. 1256

2 On-screen Indication and Data Logging of Particle Amount Measurement values can be easily logged on a personal computer by using the Interface Unit and special software (sold separately). Data from sequential sensing of particles can be used to improve quality. Realtime Clean Air Monitor A variety of displays (including color graphs for visual confirmation by color of particle densities, indication of the number of particles, and trend graphs) can be set. Particle Sensors and Interface Units can also be set from the personal computer. Measurement data is logged in real time and can be manipulated in CSV-format files using spreadsheet software. Quality Control with Multi-point Measurement Patent Pending Up to 10 Particle Sensors and up to 9 Air Clean Units can be controlled through one Interface Unit and Realtime Clean Air Monitor. There are no time-consuming restrictions, such as the order that power is turned ON. The level of cleanliness can be controlled for each process and constant monitoring is possible in relation to quality data. Cleaning / Electrostatic Sensor Air Clean Unit air volume settings, operation, and errors can be checked on the Amplifier or Interface Unit. Multi-point data output No. of connectable Sensors: 10 max. For In-line Applications Installation is simple with DIN Track mounting. The In-line Air Particle Sensor was developed for in-line applications, with a 24- VDC power supply. External outputs can be at two levels: warning and alarms. Suitable for in-line trend management applications. 1257

3 Ordering Information Air Particle Sensors Sensor Head Appearance Measured particle diameter Model 0. µm/ 0.5 µm/ 1.0 µm 0 Amplifier Units Appearance Power supply Connection method Model 24 VDC Cable connection A11 Supplied from the Air Clean Unit Connector connection (Air Clean Unit feedback connection) A12 Calculating Unit Appearance Model Cleaning / ZX-CAL2 Clean Monitoring Appearance Contents Connection method Model Set Including Communications Interface Unit and Realtime Clean Air Monitor For RS-22C connection with personal computer only For RS-22C connection with personal computer or Air Clean Unit feedback connection ZN-SFW11 ZN-SFW12 Double-sided Connector Cables (for extension between Sensor Head and Amplifier) Cable length Model Quantity 1 m ZX-XC1A 1 4 m ZX-XC4A 1 8 m ZX-XC8A 1 Type Model Quantity Sensor Head Replacement Filter Set ZN9-PF1 1 Cleaning Filter ZN9-PC1 1 Head Attachment Tool ZN9-PB

4 Ratings and Specifications Air Particle Sensors Sensor Head Item Model 0 Applicable Amplifier Measurement method Light source Applicable particle size Applicable cleanliness class Indicator Connection tube Ambient temperature Ambient humidity Dielectric strength Vibration resistance Shock resistance A11/A12 90 sideways light-scattering method Semiconductor laser 0., 0.5, or 1.0 µm min. Equivalent to Class 100 to 100,000 (FED-STD-209D) Level indicator for Class 100 to 100,000 (FED-STD-209D) Inner diameter: 4, Length: 1 m max. Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 1,000 VAC 50/60Hz for 1 min 10 to 55 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 150 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 0.5 m) Materials ABS Weight (packed state) Approx. 00 g (Packed state: Approx. 0 g) Amplifier Units Instruction sheet, connection tube Item Model A11 A12 Sampling time 1 to 599 s (selectable) Average count setting 1, 2, 4, 8, 16, 2, or 64 Indicators Status outputs (2 outputs: OUT1/OUT2) * Reset input * Functions Communications with Air Clean Unit Power supply voltage Current consumption Operation indicators: OUT1 (orange), OUT2 (yellow), 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) NPN open-collector outputs, 0 VDC, 0 ma max., Residual voltage: 1.2 V max. ON: Short-circuited with 0-V terminal or 1.5 V or less, OFF: Open Measurement result display, Setting value display, Unit selection, Scaling, Peak hold, Hysteresis setting, Threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize 24 VDC ±10%, Ripple (p-p): 10% max. 00 ma max. 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) Measurement result display, Communications condition display, Unit selection,scaling, Air Clean Unit automatic control, Air Clean Unit air level change,threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize Unique communications specifications (RJ- connector and straight LAN cable) 24 VDC ±10%, Ripple (p-p): 10% max. (Supplied from Air Clean Unit) Cleaning / Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 20 MΩ min. at 500 VDC 1,000 VAC, 50/60 Hz for 1 min 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 2 m) Connector Cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight (packed state) Approx. 180 g (Packed state: Approx. 50 g) Instruction sheet * OUT2 and the reset input are switched by using the DIP switch on the bottom of the Amplifier. 1259

5 Clean Monitoring Item Model ZN-SFW11 ZN-SFW12 Power supply voltage Current consumption Applicable Amplifiers Applicable Amplifier Unit software version Supplied from the A ma max. with 24-VDC power supply voltage (excluding current consumption and current output of the Amplifier) ZX Series, ZJ-SD Series, Series ZX-LDA@@-N V1.000 or higher, ZX-EDA@@ V1.00 or higher, ZX-TDA@@ V1.100 or higher, ZJ-SDA@@ V1.000 or higher, or A@@ V1.000 or higher No. of connectable Amplifiers 10 max. (For A) Indicators Power: Green, Sensor communications: Green, Sensor communications error: Red, External terminal communications: Green, External terminal communications error: Red Power (POWER: Green), Serial communications (STA1: Green) Not clean (OPE1: Orange), Clean (OPE2: Green) Functions Automatic control for Air Clean Units (multi-unit system control), Air level change for Air Clean Units Communications port RS-22C (9-pin, D-Sub connector) Protocol CompoWay/F Cleaning / Communications Baud rate Data configuration For external device 2 8,400 bps Data bits: 8, Parity: None, Start bits: 1, Stop bits: 1, Flow control: None Unique communications specifications (RJ- connector and straight LAN cable) Ambient temperature Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Ambient humidity Operating and storage: 5% to 85% (with no condensation) Insulation resistance 20 MΩ min. at 500 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions Shock resistance 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Connector cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight Approx. 100 g (Packed state: Approx. 480 g) Approx. 200 g (Packed state: Approx. 550 g) CD-ROM (Realtime Clean Air Monitor), Instruction Sheet, Two clamps System Connection Diagram Please refer to System Connection Diagram on page 1249 for details. Safety Precautions Refer to Warranty and Limitations of Liability on page F-2. WARNING This product is not designed or rated for ensuring safety of person. Do not use it for such purpose. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. 1260

6 Dimensions (Unit: mm) Air Particle Sensors 0 Sensor Head Mounting Tool When ZN9-PB1 is used (Sold separately) Air inlet ± dia. vinyl-insulated round cable with 10 conductors, standard length: 0.5 m Exhaust outlet Two, -dia. holes Mounting hole cutout dimensions Mounting screw holes Two, M4 holes, depth: Mounting plate Two, M4 6 mounting screws (90) ±0.1 5 Six, M Mounting hole cutout dimensions 5 Oblong holes for mounting Six, holes A11 Range indicator Unit indicator A12 Range indicator Unit indicator Modular jack dia. 1.2 OUT1 indicator OUT2 indicator (1) dia. vinyl-insulated round cable, standard length: 100 mm Main digital indicator Sub-digital indicator 15.8 Status output dia. vinyl-insulated round cable, standard length: 2 m Status output OUT2/reset input switch (default setting: status output) dia. 1.2 OUT1 indicator OUT2 indicator (1) dia. vinyl-insulated round cable, standard length: 100 mm Main digital indicator Sub-digital indicator dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m 15.8 Cleaning / Interface Units ZN-SF11 ZN-SF12 Sensor communications indicator (communicating) Sensor communications indicator (communications error) Link connector Status indicator Modular jack (.1) Connector (46) (6) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm External terminal communications indicator (communicating) External terminal communications indicator (communications error) (.1) 1.2 Operation indicators (6) (46) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm Connector Main digital indicator Sub-digital indicator dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m Cat. No. E872-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1261

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information. CSM DS_E_1_1 Continuously monitor dust fallout and particles which detract from product quality. Compact design ideal for continuous monitoring Equipped with various interfaces such as a LAN port. Accurately

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) All seven laser types provide ample long distance, for the Diffuse Reflective Model 1.000 mm and for Retroreflective

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating UV Power Monitor Monitor the Output of a UV Light Source through an Optical Fiber Cable Head Unit withstands temperatures of up to 300 C. Easy-to-read digital display of measurement values. Harmful UV

More information

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use Digital Fiber Amplifier Digital Fiber Amplifier Provides High Performance and Ease of Use First amplifier to offer three user-selectable displays: digital level, percentage and analog display Flashing

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available

More information

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification Date: 2014.6.12 Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification RoHS Symbol Amended Reason Pages Date Amended by Ref.No Approved by Checked by Drawn by Designed by Title UST-10LX

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

ABS ST700 Compact Type Series

ABS ST700 Compact Type Series Separate Type ABS ST Series (High environmental resistance type) ABS ST700 Compact Type Series Features Scale base type Absolute measurement with separate type scales Non-contact detection is optimal for

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...

More information

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm) SC-N/SA Series 7 Segment Display Unit 7 SegmneDisplay Unit With High Bright Characters (SC-N : W32 H57mm, SA Series: W H22mm) Features Selectable decimal (0 to 9) or hexadecimal (0 to 9, A to F) indication

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement NEW CMOS Multi-Function Analogue Laser Sensor IL Series A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement Seam detection

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

Hybrid Chart Recorder 250 mm (10")

Hybrid Chart Recorder 250 mm (10) Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with

More information

W100L: Laser Sensor in Mini- Format

W100L: Laser Sensor in Mini- Format Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can

More information

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying

More information

Ø50mm Shaft Multi-Turn Absolute Type

Ø50mm Shaft Multi-Turn Absolute Type Ø50mm Shaft Multi-Turn Absolute Type Diameter Ø50mm Shaft Type Multi-Turn Absolute otary Encoder Features Total 23-bit resolution (8388608-division) of 10-bit single-turn (1024-division) and 13-bit multi-turn

More information

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model ED 23 Drying and heating chambers Classic.Line with natural convection Model ED 23 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Self--powered Time Counter

Self--powered Time Counter Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to

More information

Electrical connection

Electrical connection Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With

More information

Digital Flow Switch for Large Flow

Digital Flow Switch for Large Flow 3-Color Display Digital Flow Switch for Large Flow Applicable fluid Air, N2 RoHS IP65 Flow range: Max. 12 L/min Flow ratio * 1 1:1 *1 The flow ratio is 2 : 1 for the current model (PF2A7 H/Large flow type).

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Type Contact form Model

Type Contact form Model Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features R Self -P owered Count Totalizer Subminiature Total Counters With Improved Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H PNP/NPN DC voltage input

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output SSI-1016G Manual Caution: Specifications and outline may be changed without notice MTS Sensors Technology Corporation www.mtssensor.co.jp 2010.02.04 Rev. 1 1 Revision information 2007.03.12: Data-ready

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated

More information

Separate Thin Amplifier type. AP-V40AW Series

Separate Thin Amplifier type. AP-V40AW Series Separate Thin Amplifier type AP-V40AW Series COMPACT PRESSURE SENSOR THE IDEAL SIZE FOR EASY INSTALLATION AND OPERABILITY World s Smallest Model with the Largest Character Height The world s most compact

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

V 180 Series Photoelectric Switches

V 180 Series Photoelectric Switches D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal

More information

Accessories (Order Separately)

Accessories (Order Separately) CSM_PhotoMicro_OP_E_8_ Accessories (Order Separately) Ordering Information s and Hold-down Clips Sensor models EE-SX7@ (A, P, R), EE-SX7@, EE-SY7@, EE-SPY@/@, EE-SPX0N/0N, EE-SPW/ Type Cable length Model

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No. 6 HPX-T Series Au-tuning Fiber Optic Phoelectric Control Specifications FEATURES Built-in Au-tuning Aumatically Adjusts Scanning Characteristics. Adjustment Steps, Results and Scanning Conditions Digitally

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

Type F70AB F70ABPN. Digital display. Simple operation featured

Type F70AB F70ABPN. Digital display. Simple operation featured F70Aseries Digital display Fiber optic sensors Digital indication of sensing information Simple operation for setting functions Direct reading of stablility level is available along with received light

More information

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS LVM-4000 LASER VALVE MOTION measurement system OH-1000 LASER VIBROMETER HEAD LASER-BASED TECHNOLOGY SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS ENGINE HEAD VIBRATION

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80 LWC Series LWC-80 Laser Wire Counting - Insensitive to outside light (due to interference filter, modulated light) - Visible laser spot (red light 670 nm) - Parameterisable through integrated switch and

More information

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type s with Built-in Linear Motor Type R88D-KN@-ECT-L Contents Ordering Information Specifications General Specifications Characteristics Servo Drives with 100 VAC Input Power Servo Drives with 200 VAC Input

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Product Data Sheet 4656 EZ

Product Data Sheet 4656 EZ The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

DIN Connectors DIN06 E-03

DIN Connectors DIN06 E-03 DIN Connectors DIN0 E-0 Contents Introduction HOSIDEN DIN connectors are supplied to electronic equipment manufacturers both in Japan and overseas and are very well accepted because of high quality, a

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

Safety Light Curtain Type4 SIL3 PLe

Safety Light Curtain Type4 SIL3 PLe Maximum safety standard Type4 SIL3 PLe Safety Light Curtain GL-R Series Unmatched Protection! Safety Light Curtain Strong Smart Simple GL-R Series SAFETY LIGHT CURTAINS DESIGNED FOR ANY APPLICATION RECESSED

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

No Need to Select. Intensity Detection (Previous Type)

No Need to Select. Intensity Detection (Previous Type) Color Sensing Digital Fiber Sensor CSM DS_E_5_4 Easy and Reliable he Fiber Sensor hat Sees in Color High-power white LED and multi-rgb processing eliminate the need to select light source (wavelength)

More information

ED5229GT-E Series. Page 1 of 8

ED5229GT-E Series. Page 1 of 8 ED5229GT-E Series GPON EDFA with WDM for IP (OLT) wavelengths Multi Optical Outputs (With Pluggable Cooling fans, fan speed monitoring & alarm / for Outdoor Cabinet Environment) 1310nm Forward Optical

More information

Detect Color and Shape for various inspection

Detect Color and Shape for various inspection CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information