ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features
|
|
- Whitney Cummings
- 6 years ago
- Views:
Transcription
1 Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page Features Cleaning / Smallest in the Industry! Air Particle Sensor for In-line Measurement A high-performance fan for external air suction enables constant measuring over long periods. Semiconductor laser and highsensitivity optical design in the sensing section enable measurement of 0.-µm particles. Laser beam Airflow Measurement Principle A semiconductor laser beam is targeted on to the air intake and the light is scattered when particles pass through that beam. The scattered light is received by the light receiving element and converted to an electrical signal. Particle Trend Indicator The sensing section has a particle trend display for quick visual confirmation of the degree of cleanliness. The Amplifier provides numeric indication of the number of 0.-, 0.5-, and 1.0- Particle Numeric Display Particle Trend Display µm particles. A signal can be output at any level of particles if a threshold has been set. 1256
2 On-screen Indication and Data Logging of Particle Amount Measurement values can be easily logged on a personal computer by using the Interface Unit and special software (sold separately). Data from sequential sensing of particles can be used to improve quality. Realtime Clean Air Monitor A variety of displays (including color graphs for visual confirmation by color of particle densities, indication of the number of particles, and trend graphs) can be set. Particle Sensors and Interface Units can also be set from the personal computer. Measurement data is logged in real time and can be manipulated in CSV-format files using spreadsheet software. Quality Control with Multi-point Measurement Patent Pending Up to 10 Particle Sensors and up to 9 Air Clean Units can be controlled through one Interface Unit and Realtime Clean Air Monitor. There are no time-consuming restrictions, such as the order that power is turned ON. The level of cleanliness can be controlled for each process and constant monitoring is possible in relation to quality data. Cleaning / Electrostatic Sensor Air Clean Unit air volume settings, operation, and errors can be checked on the Amplifier or Interface Unit. Multi-point data output No. of connectable Sensors: 10 max. For In-line Applications Installation is simple with DIN Track mounting. The In-line Air Particle Sensor was developed for in-line applications, with a 24- VDC power supply. External outputs can be at two levels: warning and alarms. Suitable for in-line trend management applications. 1257
3 Ordering Information Air Particle Sensors Sensor Head Appearance Measured particle diameter Model 0. µm/ 0.5 µm/ 1.0 µm 0 Amplifier Units Appearance Power supply Connection method Model 24 VDC Cable connection A11 Supplied from the Air Clean Unit Connector connection (Air Clean Unit feedback connection) A12 Calculating Unit Appearance Model Cleaning / ZX-CAL2 Clean Monitoring Appearance Contents Connection method Model Set Including Communications Interface Unit and Realtime Clean Air Monitor For RS-22C connection with personal computer only For RS-22C connection with personal computer or Air Clean Unit feedback connection ZN-SFW11 ZN-SFW12 Double-sided Connector Cables (for extension between Sensor Head and Amplifier) Cable length Model Quantity 1 m ZX-XC1A 1 4 m ZX-XC4A 1 8 m ZX-XC8A 1 Type Model Quantity Sensor Head Replacement Filter Set ZN9-PF1 1 Cleaning Filter ZN9-PC1 1 Head Attachment Tool ZN9-PB
4 Ratings and Specifications Air Particle Sensors Sensor Head Item Model 0 Applicable Amplifier Measurement method Light source Applicable particle size Applicable cleanliness class Indicator Connection tube Ambient temperature Ambient humidity Dielectric strength Vibration resistance Shock resistance A11/A12 90 sideways light-scattering method Semiconductor laser 0., 0.5, or 1.0 µm min. Equivalent to Class 100 to 100,000 (FED-STD-209D) Level indicator for Class 100 to 100,000 (FED-STD-209D) Inner diameter: 4, Length: 1 m max. Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 1,000 VAC 50/60Hz for 1 min 10 to 55 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 150 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 0.5 m) Materials ABS Weight (packed state) Approx. 00 g (Packed state: Approx. 0 g) Amplifier Units Instruction sheet, connection tube Item Model A11 A12 Sampling time 1 to 599 s (selectable) Average count setting 1, 2, 4, 8, 16, 2, or 64 Indicators Status outputs (2 outputs: OUT1/OUT2) * Reset input * Functions Communications with Air Clean Unit Power supply voltage Current consumption Operation indicators: OUT1 (orange), OUT2 (yellow), 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) NPN open-collector outputs, 0 VDC, 0 ma max., Residual voltage: 1.2 V max. ON: Short-circuited with 0-V terminal or 1.5 V or less, OFF: Open Measurement result display, Setting value display, Unit selection, Scaling, Peak hold, Hysteresis setting, Threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize 24 VDC ±10%, Ripple (p-p): 10% max. 00 ma max. 7-segment main display (red), 7-segment sub-display (yellow), power (green), wide range display (green), unit selection display (green) Measurement result display, Communications condition display, Unit selection,scaling, Air Clean Unit automatic control, Air Clean Unit air level change,threshold level selection, Wide range display, Key lock, ECO mode, Display reverse, Display digit change, Initialize Unique communications specifications (RJ- connector and straight LAN cable) 24 VDC ±10%, Ripple (p-p): 10% max. (Supplied from Air Clean Unit) Cleaning / Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Operating and storage: 5% to 85% (with no condensation) 20 MΩ min. at 500 VDC 1,000 VAC, 50/60 Hz for 1 min 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Cable (standard cable length: 2 m) Connector Cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight (packed state) Approx. 180 g (Packed state: Approx. 50 g) Instruction sheet * OUT2 and the reset input are switched by using the DIP switch on the bottom of the Amplifier. 1259
5 Clean Monitoring Item Model ZN-SFW11 ZN-SFW12 Power supply voltage Current consumption Applicable Amplifiers Applicable Amplifier Unit software version Supplied from the A ma max. with 24-VDC power supply voltage (excluding current consumption and current output of the Amplifier) ZX Series, ZJ-SD Series, Series ZX-LDA@@-N V1.000 or higher, ZX-EDA@@ V1.00 or higher, ZX-TDA@@ V1.100 or higher, ZJ-SDA@@ V1.000 or higher, or A@@ V1.000 or higher No. of connectable Amplifiers 10 max. (For A) Indicators Power: Green, Sensor communications: Green, Sensor communications error: Red, External terminal communications: Green, External terminal communications error: Red Power (POWER: Green), Serial communications (STA1: Green) Not clean (OPE1: Orange), Clean (OPE2: Green) Functions Automatic control for Air Clean Units (multi-unit system control), Air level change for Air Clean Units Communications port RS-22C (9-pin, D-Sub connector) Protocol CompoWay/F Cleaning / Communications Baud rate Data configuration For external device 2 8,400 bps Data bits: 8, Parity: None, Start bits: 1, Stop bits: 1, Flow control: None Unique communications specifications (RJ- connector and straight LAN cable) Ambient temperature Operating: 0 to 40 C, Storage: -15 to 50 C (with no icing or condensation) Ambient humidity Operating and storage: 5% to 85% (with no condensation) Insulation resistance 20 MΩ min. at 500 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions Shock resistance 00 m/s² times each in six directions (up/down, left/right, forward/backward) Connection method Connector cable (standard cable length: 2 m) Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Weight Approx. 100 g (Packed state: Approx. 480 g) Approx. 200 g (Packed state: Approx. 550 g) CD-ROM (Realtime Clean Air Monitor), Instruction Sheet, Two clamps System Connection Diagram Please refer to System Connection Diagram on page 1249 for details. Safety Precautions Refer to Warranty and Limitations of Liability on page F-2. WARNING This product is not designed or rated for ensuring safety of person. Do not use it for such purpose. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. 1260
6 Dimensions (Unit: mm) Air Particle Sensors 0 Sensor Head Mounting Tool When ZN9-PB1 is used (Sold separately) Air inlet ± dia. vinyl-insulated round cable with 10 conductors, standard length: 0.5 m Exhaust outlet Two, -dia. holes Mounting hole cutout dimensions Mounting screw holes Two, M4 holes, depth: Mounting plate Two, M4 6 mounting screws (90) ±0.1 5 Six, M Mounting hole cutout dimensions 5 Oblong holes for mounting Six, holes A11 Range indicator Unit indicator A12 Range indicator Unit indicator Modular jack dia. 1.2 OUT1 indicator OUT2 indicator (1) dia. vinyl-insulated round cable, standard length: 100 mm Main digital indicator Sub-digital indicator 15.8 Status output dia. vinyl-insulated round cable, standard length: 2 m Status output OUT2/reset input switch (default setting: status output) dia. 1.2 OUT1 indicator OUT2 indicator (1) dia. vinyl-insulated round cable, standard length: 100 mm Main digital indicator Sub-digital indicator dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m 15.8 Cleaning / Interface Units ZN-SF11 ZN-SF12 Sensor communications indicator (communicating) Sensor communications indicator (communications error) Link connector Status indicator Modular jack (.1) Connector (46) (6) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm External terminal communications indicator (communicating) External terminal communications indicator (communications error) (.1) 1.2 Operation indicators (6) (46) 5.2-dia. vinyl-insulated round cable, standard length: 00 mm Connector Main digital indicator Sub-digital indicator dia. vinyl-insulated round cable with 10 conductors (conductor cross-section: 0.08 mm², insulator diameter: 0.7 mm), standard length: 2 m Cat. No. E872-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1261
Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements
NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More informationZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.
CSM DS_E_1_1 Continuously monitor dust fallout and particles which detract from product quality. Compact design ideal for continuous monitoring Equipped with various interfaces such as a LAN port. Accurately
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More information1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for
More informationE8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors
Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting
More informationPhotoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) All seven laser types provide ample long distance, for the Diffuse Reflective Model 1.000 mm and for Retroreflective
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationOrdering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.
Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationAP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display
AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest
More informationUV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating
UV Power Monitor Monitor the Output of a UV Light Source through an Optical Fiber Cable Head Unit withstands temperatures of up to 300 C. Easy-to-read digital display of measurement values. Harmful UV
More informationDigital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use
Digital Fiber Amplifier Digital Fiber Amplifier Provides High Performance and Ease of Use First amplifier to offer three user-selectable displays: digital level, percentage and analog display Flashing
More informationModel Number Structure
Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control
More informationPressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display
Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available
More informationScanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification
Date: 2014.6.12 Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification RoHS Symbol Amended Reason Pages Date Amended by Ref.No Approved by Checked by Drawn by Designed by Title UST-10LX
More information20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)
OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for
More informationSafety Light Curtains
4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent
More informationEVENT INPUT/OUTPUT MODULE [PUME]
PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm
More informationSENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission
Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc
More informationR87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information
Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationABS ST700 Compact Type Series
Separate Type ABS ST Series (High environmental resistance type) ABS ST700 Compact Type Series Features Scale base type Absolute measurement with separate type scales Non-contact detection is optimal for
More informationR1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)
INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationType Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US
Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC
More informationWeekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min
Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable
More informationOperating Instructions
COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...
More information7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)
SC-N/SA Series 7 Segment Display Unit 7 SegmneDisplay Unit With High Bright Characters (SC-N : W32 H57mm, SA Series: W H22mm) Features Selectable decimal (0 to 9) or hexadecimal (0 to 9, A to F) indication
More informationMBUS 10 RS232 TO MBUS LEVEL CONVERTER
Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationI-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement
NEW CMOS Multi-Function Analogue Laser Sensor IL Series A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement Seam detection
More informationSolid-State Digital Timer
Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,
More informationR87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure
Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.
More informationHybrid Chart Recorder 250 mm (10")
Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with
More informationW100L: Laser Sensor in Mini- Format
Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can
More informationModel FP 240 Drying and heating chambers Classic.Line with forced convection and program functions
Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying
More informationØ50mm Shaft Multi-Turn Absolute Type
Ø50mm Shaft Multi-Turn Absolute Type Diameter Ø50mm Shaft Type Multi-Turn Absolute otary Encoder Features Total 23-bit resolution (8388608-division) of 10-bit single-turn (1024-division) and 13-bit multi-turn
More informationModel ED 23 Drying and heating chambers Classic.Line with natural convection
Model ED 23 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More information1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.
ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read
More informationElectronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,
Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999
More informationSelf--powered Time Counter
Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to
More informationElectrical connection
Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With
More informationDigital Flow Switch for Large Flow
3-Color Display Digital Flow Switch for Large Flow Applicable fluid Air, N2 RoHS IP65 Flow range: Max. 12 L/min Flow ratio * 1 1:1 *1 The flow ratio is 2 : 1 for the current model (PF2A7 H/Large flow type).
More informationSTBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number
More informationKramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher
Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationType Contact form Model
Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationOrdering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features
R Self -P owered Count Totalizer Subminiature Total Counters With Improved Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H PNP/NPN DC voltage input
More informationINSTALLATION MANUAL FT-FOTR-1VDE-ST-S
INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package
More information1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output
SSI-1016G Manual Caution: Specifications and outline may be changed without notice MTS Sensors Technology Corporation www.mtssensor.co.jp 2010.02.04 Rev. 1 1 Revision information 2007.03.12: Data-ready
More informationODW-621. RS-232 Point-to-point applications
Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationXW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations
Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated
More informationSeparate Thin Amplifier type. AP-V40AW Series
Separate Thin Amplifier type AP-V40AW Series COMPACT PRESSURE SENSOR THE IDEAL SIZE FOR EASY INSTALLATION AND OPERABILITY World s Smallest Model with the Largest Character Height The world s most compact
More informationL-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL
L-LAS Series - Line laser
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationAES-404 Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationV 180 Series Photoelectric Switches
D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal
More informationAccessories (Order Separately)
CSM_PhotoMicro_OP_E_8_ Accessories (Order Separately) Ordering Information s and Hold-down Clips Sensor models EE-SX7@ (A, P, R), EE-SX7@, EE-SY7@, EE-SPY@/@, EE-SPX0N/0N, EE-SPW/ Type Cable length Model
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationSU17 Series Fiber Optic Sensors
SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference
More informationHPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.
6 HPX-T Series Au-tuning Fiber Optic Phoelectric Control Specifications FEATURES Built-in Au-tuning Aumatically Adjusts Scanning Characteristics. Adjustment Steps, Results and Scanning Conditions Digitally
More informationCylindrical Photoelectric Sensor CY-100 SERIES
Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector
More informationType F70AB F70ABPN. Digital display. Simple operation featured
F70Aseries Digital display Fiber optic sensors Digital indication of sensing information Simple operation for setting functions Direct reading of stablility level is available along with received light
More informationLVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS
LVM-4000 LASER VALVE MOTION measurement system OH-1000 LASER VIBROMETER HEAD LASER-BASED TECHNOLOGY SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS ENGINE HEAD VIBRATION
More informationL-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:
L-LAS Series L-LAS-LT-50-SL-... - Line laser
More informationAK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:
AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic
More informationLWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80
LWC Series LWC-80 Laser Wire Counting - Insensitive to outside light (due to interference filter, modulated light) - Visible laser spot (red light 670 nm) - Parameterisable through integrated switch and
More informationG5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type
s with Built-in Linear Motor Type R88D-KN@-ECT-L Contents Ordering Information Specifications General Specifications Characteristics Servo Drives with 100 VAC Input Power Servo Drives with 200 VAC Input
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationProduct Data Sheet 4656 EZ
The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationOM2000N INSTALLATION MANUAL
OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,
More informationProduct Data Sheet 4656 ZW
The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationDIN Connectors DIN06 E-03
DIN Connectors DIN0 E-0 Contents Introduction HOSIDEN DIN connectors are supplied to electronic equipment manufacturers both in Japan and overseas and are very well accepted because of high quality, a
More informationElectrical connection
Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication
More informationMG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV
MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper
More informationSafety Light Curtain Type4 SIL3 PLe
Maximum safety standard Type4 SIL3 PLe Safety Light Curtain GL-R Series Unmatched Protection! Safety Light Curtain Strong Smart Simple GL-R Series SAFETY LIGHT CURTAINS DESIGNED FOR ANY APPLICATION RECESSED
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationOPTICAL POWER METER WITH SMART DETECTOR HEAD
OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationLD OEM/LD PDS/LD PeCo
LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class
More informationNo Need to Select. Intensity Detection (Previous Type)
Color Sensing Digital Fiber Sensor CSM DS_E_5_4 Easy and Reliable he Fiber Sensor hat Sees in Color High-power white LED and multi-rgb processing eliminate the need to select light source (wavelength)
More informationED5229GT-E Series. Page 1 of 8
ED5229GT-E Series GPON EDFA with WDM for IP (OLT) wavelengths Multi Optical Outputs (With Pluggable Cooling fans, fan speed monitoring & alarm / for Outdoor Cabinet Environment) 1310nm Forward Optical
More informationDetect Color and Shape for various inspection
CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view
More informationProduct Data Sheet 8506 VW-691
The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationMultifunction Digital Timer
Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationLinear encoders without bearings incremental System for linear motion feedback
Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system
More informationPanel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features
NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description
More information