T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L
|
|
- Dortha Anastasia Page
- 6 years ago
- Views:
Transcription
1 T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations in mains voltage average service life = 0,000 h (at ta max. with a failure rate 0. % per 00 operating hours) AC voltage range 18 V DC voltage range V, (lamp start 18 V DC) overvoltage protection 0 V AC, 1 h overvoltage indication starting at input voltage 0 V AC undervoltage protection (shut down) < 0 V AC / 17 V DC operating frequency khz suitable for automatic and manual wiring with insulation displacement connector (IDC) wide operating temperature range from - C to +0 C suitable for use in emergency lighting installations in accordance with VDE 08 safe swih off of defective lamps automatic re-start after lamp change for luminaires with or and in acc. with EN 08 / VDE 07 and VDE 07 protection class SK I and SK II IP 0 thermal protection according to EN 17-- Ce Certified: EN 0 EN 0 EN 17-- EN 17-- EN 0 EN 0 EN 00-- EN 7 in accordance with VDE 08 IEC 8-- Fh IEC 8-- Eb IEC 8--0 Lamp Ballast watt- type type article length fixing weight lamp circuit Celma current at 0 Hz λ at 0 Hz point temperature age number centres power power class 0 V 0 V 0 V 0 V range W mm D mm kg W W EEI A A C C x T8 PC // T Pro lp 0 0 V 0/0/0 Hz A x T8 PC // T Pro lp 0 0 V 0/0/0 Hz A x18 T8 PC // T Pro lp 0 0 V 0/0/0 Hz A x18 T8 PC // T Pro lp 0 0 V 0/0/0 Hz A x T PC 1/ T Pro lp 0 0 V 0/0/0 Hz A x T PC / T Pro lp 0 0 V 0/0/0 Hz A x T PC // T Pro lp 0 0 V 0/0/0 Hz A x T PC // T Pro lp 0 0 V 0/0/0 Hz A x T PC 1/ T Pro lp 0 0 V 0/0/0 Hz A x T PC / T Pro lp 0 0 V 0/0/0 Hz A x T PC 1/ T Pro lp 0 0 V 0/0/0 Hz A x T PC / T Pro lp 0 0 V 0/0/0 Hz A x T PC 1/ T Pro lp 0 0 V 0/0/0 Hz A x T PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz A x TCL PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz A x80 T PC 1/80 T Pro lp 0 0 V 0/0/0 Hz A x80 T PC /80 T Pro lp 0 0 V 0/0/0 Hz A measured according to EN 0 Types will be replaced by the new generation until May 008. Data sheet 1/07--7 We reserve the right to make technical changes without prior notice.
2 Lamp starting characteristics Warm start Starting time 1. secs with AC and DC operation Cathode heating will be reduced after preheat time AC operation Mains voltage: 0 0 V 0/0 Hz 18 V 0/0 Hz including safety tolerance (± %) 0 V 0/0 Hz including performance tolerance (+ % / -8 %) DC operation 0 0 V 0 Hz V 0 Hz certain lamp start V 0 Hz operating range Light output level in DC operation: 0 % Emergency lighting Use in emergency lighting installations according to VDE 08 or for emergency luminaires according to EN 17-- appendix J. Mains currents in DC operation type lamp wattage mains current at mains current at type W Un = 0 VDC Un = 0 VDC PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 07 ma 10 ma PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 7 ma ma PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 7 ma 18 ma PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 17 ma 1 ma PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 8 ma ma PC / T Pro lp 0 0 V 0/0/0 Hz T x ma 0 ma PC // T Pro lp 0 0 V 0/0/0 Hz T x 8 ma ma PC // T Pro lp 0 0 V 0/0/0 Hz T x ma 08 ma PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x ma 178 ma PC / T Pro lp 0 0 V 0/0/0 Hz T x 7 ma ma PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 7 ma ma PC / T Pro lp 0 0 V 0/0/0 Hz T x 8 ma ma PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x ma ma PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz T x 8 ma 8 ma PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz TCL x 8 ma 8 ma PC 1/80 T Pro lp 0 0 V 0/0/0 Hz T 1x80 00 ma ma PC /80 T Pro lp 0 0 V 0/0/0 Hz T x80 78 ma 7 ma Instant start after mains interruption < 0. s Intelligent Voltage Guard Intelligent Voltage Guard is the name of the new electronic monitor from TridonicAo. This innovative feature of the PC PRO family of control gear from TridonicAo immediately shows if the mains voltage rises above or falls below certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. If the mains voltage rises above 0 V the lamps start flashing on and off. This signal demands disconnection of the power supply to the lighting system. If the mains voltage falls below 0 V the control gear automatically disconnects the lamp circuit to protect the control gear from being irreparably damaged. Harmonic distortion in the mains supply type lamp wattage THD type W at 0 V / 0 Hz PC // T Pro lp 0 0 V 0/0/0 Hz T8 x < 1 % PC // T Pro lp 0 0 V 0/0/0 Hz T8 x < % PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 < 1 % PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 < % PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x < % PC / T Pro lp 0 0 V 0/0/0 Hz T x < % PC // T Pro lp 0 0 V 0/0/0 Hz T x < % PC // T Pro lp 0 0 V 0/0/0 Hz T x < % PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x < % PC / T Pro lp 0 0 V 0/0/0 Hz T x < % PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x < % PC / T Pro lp 0 0 V 0/0/0 Hz T x < % PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x < % PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz T x < % PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz TCL x < % PC 1/80 T Pro lp 0 0 V 0/0/0 Hz T 1x80 < % PC /80 T Pro lp 0 0 V 0/0/0 Hz T x80 < % Smart Heating Innovative heating circuit. Reduced filament heating after lamp has struck. Data sheet 1/07--7 We reserve the right to make technical changes without prior notice.
3 Output voltage type lamp wattage U out type W PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 0 V PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 0 V PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 0 V PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 0 V PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 0 V PC / T Pro lp 0 0 V 0/0/0 Hz T x 0 V PC // T Pro lp 0 0 V 0/0/0 Hz T x 0 V PC // T Pro lp 0 0 V 0/0/0 Hz T x 0 V PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 0 V PC / T Pro lp 0 0 V 0/0/0 Hz T x 0 V PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 00 V PC / T Pro lp 0 0 V 0/0/0 Hz T x 00 V PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 0 V PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz T x 0 V PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz TCL x 0 V PC 1/80 T Pro lp 0 0 V 0/0/0 Hz T 1x80 0 V PC /80 T Pro lp 0 0 V 0/0/0 Hz T x80 00 V Ballast lumen factor EN type lamp wattage AC/DC-BLF type W at U = 18 V, C and C PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 0. PC // T Pro lp 0 0 V 0/0/0 Hz T8 x 0. PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 0. PC // T Pro lp 0 0 V 0/0/0 Hz T8 x18 0. PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 1.00 PC / T Pro lp 0 0 V 0/0/0 Hz T x 1.00 PC // T Pro lp 0 0 V 0/0/0 Hz T x 1.0 PC // T Pro lp 0 0 V 0/0/0 Hz T x 1.07 PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 1.00 PC / T Pro lp 0 0 V 0/0/0 Hz T x 1.00 PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 1.00 PC / T Pro lp 0 0 V 0/0/0 Hz T x 1.00 PC 1/ T Pro lp 0 0 V 0/0/0 Hz T 1x 1.00 PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz T x 1.00 PC / T / / TCL Pro lp 0 0 V 0/0/0 Hz TCL x 0. PC 1/80 T Pro lp 0 0 V 0/0/0 Hz T 1x PC /80 T Pro lp 0 0 V 0/0/0 Hz T x ASIC light management ASIC (Application specific integrated circuit) is the very latest in lighting management design technology. The lamp friendly warm start in 1. seconds and a whole series of energy saving measures and light management feature make PC T Pro lp a real champion in its class. Energy class CELMA EEI = A PC T Pro lp ignition technology (smart heating) optimises lamp start and ensures no energy is wasted. After the lamp has struck the filament heating is reduced automatically to a defined minimum value. This reduction in filament heating, saves energy, yet maintains the proper operating conditions for the lamp. The lamp is always operated within specification. Data sheet 1/07--7 We reserve the right to make technical changes without prior notice.
4 Ambient Temperature PC 1x T Pro lp mm mm point is related to the ballast life duration. PC T PRO LP is designed for an average service life of 0,000 hours under reference conditions and with a failure probability of less than %. This corresponds to an average failure rate of 0. % for every 1,000 hours of operation. PC 1x80 T Pro lp PC x T Pro lp PC x80 T Pro lp PC // T Pro lp 78 mm 1 mm mm mm Loading of automatic circuit breakers Automatic circuit breaker type C C1 C C0 B B1 B B0 Installation 1. mm 1. mm. mm.0 mm 1. mm 1. mm. mm.0 mm PC 1/ T Pro lp PC 1/ T Pro lp PC 1/ T Pro lp PC 1/ T Pro lp PC 1/80 T Pro lp PC / T Pro lp PC / T Pro lp PC / T Pro lp PC / T / / TCL Pro lp PC /80 T Pro lp PC // T Pro lp Wiring advice The lead length is dependant on the capacitance of the cable. For safety reasons, the PC T Pro lp must only be earthed in the case of a safety class 1 luminaire. Earthing is not required for the device to operate. Connection to earth reduces radio interference. Ballast Terminal Maximum capacitance Type allowed Cold Hot Cold Hot PC 1/xx T Pro lp, 1, 00 pf 0 pf PC /xx T Pro lp, 1, 1, 1,,, 00 pf 0 pf PC / TCL Pro lp, 1, 1, 1,,, 00 pf 0 pf PC // T Pro lp,, 7, 8,, 1,,, 00 pf 0 pf With standard solid wire 0./0.7 mm² the capacitance of the lead is 0 80 pf/m. This value is influenced by the way the wiring is made. keep lamp wires short lamp connection should be made with symmetrical wiring hot leads,,, and cold leads, 1, 1, 1 should be separated as much as possible T lamp information T High Output (FQ) wattage length W mm W 8 mm W 1 mm W mm 80 W 1 mm T8 lamp information wattage length 18 W 0 mm Installation instructions IDC interface solid wire with a cross section of 0. mm² according to the specification from WAGO alternatively a flexible lead with a cross section of 0.7 mm² Horizontal interface solid wire with a cross section of mm² according to the specification from WAGO solid wire with a cross section of 1.0 mm² with an insulation diameter up to. mm strip mm of insulation from the cables to ensure perfect operation of the screw terminals Loosen wire through twisting and pulling wire preparation: mm Loosen wire through twisting and pulling Data sheet 1/07--7 We reserve the right to make technical changes without prior notice.
5 RFI TridonicAo ballasts are RFI protected in accordance with EN 0 and EN 0. To operate the luminaire correctly and and to minimise RFI we recommend the following instructions: Connection to the lamps of the hot leads must be kept as short as possible (marked with *) Mains leads should be kept apart from lamp leads (ideally cm distance) Do not run mains leads adjacent to the electronic ballast Twist the lamp leads Keep the distance of lamp leads from the metal work as large as possible Ballast must be earthed, either over the terminal or over the mounting screw of the ballast Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible Defective lamp (Broken filament, rectifying effect, gas defect) If a lamp is defective, the ballast swihes off and goes into standby. There is an automatic restart once the lamp has been changed. Side fixing feature Screw M, screw head diameter 8 mm Packing quantities PC 1x T Pro lp * pieces/carton cartons/pallet 0 pieces/pallet PC 1x80 T Pro lp and PC x T Pro lp * pieces/carton 7 cartons/pallet 70 pieces/pallet PC x80 T Pro lp and PC // T Pro lp pieces/carton cartons/pallet 8 pieces/pallet * New packaging concept PC x TC-L Pro lp leads,,, max. 1.0 m (< 0 pf) leads, 1, 1, 1 max..0 m (< 00 pf) SK I - luminaires: earth of ballast housing required (according to IEC 8) Optimised packaging concept for the transportation of ballasts, that provide a 1 % reduction in packaging per ballast. Thus minimising environmental impact and reducing recycling costs associated by separating waste PC 1x 80 T Pro lp leads, max. 1.0 m (< 0 pf) leads, 1 max..0 m (< 00 pf) SK I - luminaires: earth of ballast housing required (according to IEC 8) PC x 80 T Pro lp leads,,, max. 1.0 m (< 0 pf) leads, 1, 1, 1 max..0 m (< 00 pf) SK I - luminaires: earth of ballast housing required (according to IEC 8) PC x T Pro lp leads,,, max. 1.0 m (< 0 pf) leads,, 7, 8,, 1 max..0 m (< 00 pf) SK I - luminaires: earth of ballast housing required (according to IEC 8) PC x T Pro lp leads,,, max. 1.0 m (< 0 pf) leads,, 7, 8,, 1 max..0 m (< 00 pf) SK I - luminaires: earth of ballast housing required (according to IEC 8) Data sheet 1/07--7 We reserve the right to make technical changes without prior notice.
LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White
Driver LCAI 38/75W TW lp Tunable White Product description 2-channel LED Driver with LI DT8 Output power: 38 W or 75 W Power input on standby < 0.3 W Nominal life-time up to 50,000 h 5-year guarantee Properties
More informationEmergency lighting units EM powerled
E 15 W CE CPS ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation
More informationEmergency lighting units EM powerled
CE CPS 12/15 W ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation
More informationHID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp
Product description Pulse packets for increased ignition energy (pulsecontrol technology) Flicker-free light Colour stability thanks to constant power No acoustic resonance Safety shutdown if a lamp is
More informationLED Driver Linear / area fixed output
Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For
More informationLED Driver Compact dimming
Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250
More informationLED Driver Compact fixed output
Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000
More informationOUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor
Product description Pulse packets for increased ignition energy (pulsecotro technology) Flicker-free light Colour stability thanks to constant power o acoustic resonance Safety shutdown if a lamp is faulty
More informationLED control gear Compact fixed output
Driver LC 40W 900mA fixc SR SNC ESSENCE series Product description Independent fixed output LED Driver Constant current LED Driver Output current 900 ma Max. output power 39 W Nominal life-time up to 50,000
More informationPHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series
Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 30,000 h For luminaires of protection class I and protection
More informationCatalogue Ignitors and power switches for HID
Catalogue 2012 Ignitors and power switches for HID Overview Product overview Ignitor matrix Standards Page 6 Page 7 Page 8 Product information Ignitors and power switches for HID Page 9 Superimposed-pulse
More informationLED Driver Compact fixed output
Driver LC 40W 900mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 50,000
More informationHELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS
Ballasts HELVAR CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts 4-17 Helvar is an international lighting technologies company specialised in energy efficient components and solutions
More informationHYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.
More informationLED Driver Compact fixed output
Driver LC 10W 250mA fixc R ADV ADV series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 250 ma For luminaires of protection class II For ambient temperatures
More informationHID control gear Electronic
HS HI S,, PCS outdoor DIM chronostep outdoor Product description Pulse packets for increased ignition energy (pulsecotro technology) Flicker-free light Colour stability thanks to constant power o acoustic
More informationPHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor
Product description Pulse packets for increased ignition energy (pulsecotro technology) Flicker-free light Colour stability thanks to constant power o acoustic resonance Safety shutdown if a lamp is faulty
More informationLED MODULES READYLINE DL
LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH
More informationEmergency lighting units EM INVERTER
EM IVERTER TC-DE TC-TE TC-F TC-DD Tc EM MII BAIC, 0 0 V 0/0 Hz BAIC version roduct description Emergency lighting supply unit f manual testing F compact fluescent lamps mall dimensions ( x 0 mm cross-section,
More informationHYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency
More informationLED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series
Driver LC 200W 1050mA UNV ADV IND ADVANCED series Product description Independent constant current LED Driver For dry, damp and wet locations Max. output power 200 W Up to 93.7 % efficiency For luminaires
More informationLED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data
Product description Dimmable built-in for LED Constant current (with 2 adjustable output channels) Designed for outdoor and street luminaire Output power 2 x 38 W Suitable for mains voltage peaks (burst/surge)
More informationLED Driver Linear / area dimming
Driver LCA 75W 350 1050mA one4all lp PRE PREMIUM series Product description Dimmable built-in constant current LED Driver Adjustable output current between 350 and 1,050 ma via ready2mains Programmer,
More informationOT 100/ /700 P5
OT 100/120 277/700 P5 OPTOTRONIC Outdoor Constant current LED drivers Areas of application _ Street and urban lighting _ Industry _ Suitable for luminaires of protection class I Product benefits _ High
More informationQUICKTRONIC FIT 8. Product family datasheet. ECG for FL 26 mm
QUICKTRONIC FIT 8 ECG for FL 26 mm Areas of application _ Open-plan offices, corridors and storage rooms _ Public buildings _ Strip lighting _ Suitable for emergency lighting (DC operation) _ Suitable
More informationLED Driver Constant voltage
Driver LCA 150W 24V one4all SC PRE PREMIUM series Product description Dimmable 24 V constant voltage LED Driver for flexible constant voltage strips One4all interface and ready2mains enable different dimming
More informationQTi DALI 2X14/24/ DIM
QTi DALI 2X14/24/220 240 DIM QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100 Product benefits Same luminous flux with direct
More informationOPTOTRONIC Intelligent
OPTOTRONIC Intelligent Compact constant current LED drivers Dimmable DALI Areas of application _ Installation in emergency lighting systems according to IEC 61347-2-13, appendix J _ Suitable for use in
More informationLED Driver Compact dimming
Driver LCA 45W 500 1400mA one4all C PRE PREMIUM series Product description Dimmable built-in constant current LED Driver Adjustable output current between 500 and 1,400 ma via ready2mains Programmer, I-select
More informationPHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version
EM IVERTER TC-DE TC-TE roduct description Emergency lighting supply unit f manual testing F compact fluescent lamps mall dimensions ( x 0 mm cross-section, 0 mm length) -year guarantee roperties h rated
More informationPRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM
QTi DALI-T/E 2X18 42 DIM QUICKTRONIC INTELLIGENT DALI DIM CFL ECG dimmable DALI for CFL AREAS OF APPLICATION Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100 Installation
More informationLED Driver Compact dimming
Driver LCA 120W 350 1050mA one4all C PRE OTD PREMIUM Outdoor series Product description Dimmable built-in constant current LED Driver Output current adjustable between 350 1,050 ma via ready2mains Programmer,
More informationLED Driver Compact dimming
Driver LCA 17W 250 700mA one4all C PRE PREMIUM series Product description Dimmable built-in constant current LED Driver Adjustable output current between 250 and 700 ma via ready2mains Programmer, I-select
More informationThe systematic way to get more light In most cases, the lamp developments are effectively system developments as they also involve modern electronic
The systematic way to get more light In most cases, the lamp developments are effectively system developments as they also involve modern electronic control gear at every stage. This is the only way to
More informationOPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.
OPTOTRONIC FIT inear / Area Constant Current Non dimmable Areas of application Installation in emergency lighting systems according to IEC 61347-2-3, appendix J Suitable for installation in emergency lighting
More informationLED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data
Product description 1-channel for indoor use Inbuilt for luminaires of protection class I Output current and output voltage adjustable FA output 12 V TC input channel ominal life of 50,000 h (at ta max.
More informationDatasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers
LED Transformers Datasheet LED Transformers LED Transformer 120W 24V 220-240V Product description Philips full-electronic constant voltage LED Transformers are designed to operate 24VDC LED solutions used
More informationTechnical Information
Reference: For use with LED light engines Geometry (l x w x h): Line voltage, nominal Perm. voltage fluctuations Line current, nominal Inrush current, typical Line frequency Protection Class Output operating
More information2L-CG-Monitoring Module
2-CG-Monitoring Module 2-CG 2-CG 0.06 kg of mounting (H x x B) 27.5 x x Connection terminals oop terminals 2 x 2.5 mm 2 Voltage ranges 230 V 50/60 Hz, 220 V DC +25/-20 % see ordering details Max. length
More informationFeatures. High Brightness SMD LED Light source
www.edison-opto.com Solid-State Lighting Series 5W MR16 DATASHEET Features High Brightness SMD LED Light source Ecologically Friendly Energy Efficient General Information... 1 Product Dimensions... 2 Product
More informationQTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.
QTi 2X28/54 DIM QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm Areas of application Suitable for emergency installations Industry Open-plan offices, corridors and storage rooms Public
More informationPRODUCT FAMILY DATASHEET QUICKTRONIC PROFESSIONAL DL
QUICKTRONIC PROFESSIONAL DL ECG for CFL AREAS OF APPLICATION Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100 Open-plan offices, corridors and storage rooms Public buildings Suitable for
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationPRODUCT FAMILY DATASHEET QUICKTRONIC MULTIWATT
QUICKTRONIC MULTIWATT ECG for CFL AREAS OF APPLICATION Emergency lighting systems acc. to EN 50172 / DIN VDE 0108-100 Public buildings Sports halls and factories Suitable for luminaires of protection class
More informationOrdering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)
luxcotro lighting control system Control module for amplifying signals Product description Multi-functional controller For amplifying the signal for a maximum of 50 devices or for cascading long lines
More informationIndoor Linear 80W Driver SI-C215280N2KR
Product Data Sheet Rev.00 2017. 2. 9 1# LED Driver Indoor Linear 80W Driver SI-C215280N2KR Constant Current LED Driver Features & Benefits Output Current Range: 1550mA Output Voltage Range: MAX 51 Vdc
More informationLED Driver Compact dimming
Driver LCA 17W 250 700mA one4all SC PRE PREMIUM series Product description Dimmable built-in constant current LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory)
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More informationILT-54HO-T5C/277 F54T5 HO > 0.98 ILT-39HO-T5C/277 F39T5 HO > 0.98 ILT-24HO-T5C/277 F24T5 HO > 0.
Smaller Than a Dime With a cross section of just mm x mm the ILT Miniature HE, Miniature HO, and Two Lamp ballast height is as small as the mm diameter T5 lamp it operates. Your fixture design no longer
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationRoof-mounted Blue e+ cooling unit Integration solution VX25
Roof-mounted Blue e+ cooling unit Integration solution VX25 Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ Cooling unit with 1.3 kw and Blue e+ technology with
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationSecto Design Oy Kauppalantie Kauniainen Finland tel fax
Secto Design Oy Kauppalantie 12 02700 Kauniainen Finland tel. +358 9 5050598 fax +358 9 5475 2535 info@sectodesign.fi www.sectodesign.fi Owalo 7000 pendant natural birch, black laminate or white laminate,
More informationLINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS
MUSIUM RESTAURANT SOUVENIR SHOP EXIT LinkRay Modulators 12 V / 24 V Constant-voltage Applications LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE LINK-RAY TM MODULATORS FOR CONSTANT-VOLTAGE APPLICATIONS 186755
More informationActuators IC 20, IC 40
Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions
More informationQUICKTRONIC INTELLIGENT DALI DIM T8
QUCKTRONC NTELLGENT DAL DM T8 ECG dimmable DAL for FL 26 mm Areas of application _ Suitable for use in emergency lighting systems as per EN 50172/DN VDE 0108-100 _ nstallation in emergency lighting systems
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationGordian. Multifunctional Power Distributor / Conditioner. v1.3
Owner s Manual Gordian Multifunctional Power Distributor / Conditioner www.lab12.gr v1.3 Table of Contents It is yours Unpacking and warnings Installation & placement Front panel Rear panel connections
More informationElectrical connection
Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.
Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.
Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationFigure 1: Device components
Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe
More informationAmerican National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts
American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts Secretariat: National Electrical Manufacturers Association Approved: January 23, 2017 American National Standards Institute,
More informationCyclo Series. user manual. MartinArchitectural
Cyclo Series user manual MartinArchitectural Measurements are in millimeters 63 Cyclo 02 88 Cyclo 03 1000 81 1190 88 Cyclo 04 98 88 2002 Martin Professional A/S, Denmark. All rights reserved. No part of
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationDALI TOUCHPANEL BASIC TW. Operating and control unit
BASIC Operating and control unit Product description Capacitive Touchpanel High-quality appearance with real glass display Multiple control modules are possible in a system Power supply via line Double
More informationTOSHIBA Industrial Magnetron E3328
TOSHIBA E3328 is a fixed frequency continuous wave magnetron intended for use in the industrial microwave heating applications. The average output power is 3kW in the frequency range from 2450 to 2470
More informationOperating Instructions Dimmer for V Incandescent Lamps
Operating Instructions Incandescent Lamps 1. Safety instructions Attention: Electrical equipment must be installed and fitted only by qualified electricians and in observance of the current accident prevention
More informationGV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals
Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application
More information110LP MOON Series. Phono Preamplifier. Owner s Manual
Phono Preamplifier Owner s Manual Owner s Manual I Table of Contents Introduction 4 Unpacking 5 Installation & Placement 5 Circuit Board Layout s 6 Internal Adjustments 7 Rear Panel Connections 8 Operating
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationLED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES
pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationUniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications
Lighting UniStreet simple, costeffective road-lighting range UniStreet At relatively low initial cost, the highly efficient LED-based UniStreet luminaire offers significant cost savings compared with conventional
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationThe performance of a lifetime. Owner s Manual MOON 110LP v2 Phono Preamplifier
The performance of a lifetime Owner s Manual MOON 110LP v2 Phono Preamplifier MOON by Simaudio simaudio.com Simaudio Ltd 1345 Newton Road, Boucherville, Québec J4B 5H2 CANADA Date Code: 20180831 01 INTRODUCTION
More informationPRINCIPLES AND APPLICATIONS
GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationLuminaire installation box Surface-mounted box Ceiling installation box
-Smart PTM Ambient light sensor and motion detector for constant lighting control uminaire installation box Surface-mounted box Ceiling installation box Overview: -SMART PTM i is an ambient light sensor,
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationEA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator
EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More informationOptical Signal Devices. Free-standing Beacons
Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More information1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.
Art.-No.: 1202 URE Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationGV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals
Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology
More informationSubstiTUBE Value EM Fighter Tube Technical Datasheet
SubstiTUBE Value EM Fighter Tube Technical Datasheet APM LED LAMPS FY17 PRODUCT INTRODUCTION 201701 Product Licensee of trademark OSRAM in general lighting Glass SubstiTUBE Value EM Fighter Tube Innovative
More information