1 MEGALOOK English Manual Version: 1.00

2 2

3 Table of contents 1 Description Digital- and analogue measurement data NIT function Memory DiSEqC compatibel Operation Unpacking Connection Maintenance Battery check SAT-TV mode Picture mode Functions in picture mode Digital mode NIT - Network Information Table Functions in digital mode Span Min / Span Max X-pol DiSEqC Setup Beeper Special functions Memory for storing spectrum pictures TV mode Picture mode TV Text Sound Manual attenuation Beeper Manual attenuation Memory Ext A/V Digital mode Cable Channels Zoom IQ Span Modulation Symbol rate Terrestrial Channels Zoom IQ Span Span Max hold Center Set up Reference cursor User Span Memory Channelpower PC-software Firmware upgrade Technical specification

4 1 Description MEGALOOK is a digital satellite-tv and TV-instrument with a spectrumanalyzer. MEGALOOK is developed and produced in Sweden by Emitor AB and helps professional users to do exact adjustments and maintenance of satellite dishes and of cable TV and terrestrial networks. Since MEGALOOK is microprocessor controlled, all important functions can be controlled by a controlknob and a few controlbottons. The basic functions of the instrument are easy to learn and even beginners can start using it after basically a few minutes of instructions. 1.1 Digital- and analogue measurement data TV-picture, a spectrum showing the entire frecuency band (or parts thereof) or digital measurement data are shown on a 4,5" black and white (B/W) monitor. Analogue satellite TV channels can be tuned in and watched (Multistandard Video PAL, NTSC and SECAM) and soundfrequencies between MHz can be tuned in and listened to. MEGALOOK has a spectrumfunction that shows the frequency band MHz. This function makes it very easy to detect satellite signals. The spectrum can be expanded to make more precise adjustments possible (maximum zoom in is 250 MHz) or to do a cross-polarisation. The instrument has a high resolution and accuracy. It presents measuring values with ± 2dB at room temperature, about 20 C. The tuning-in of a frequency is made by the controlknob (1step = 1MHz) and the tuned frequency is shown on the B/W monitor or on the LCD display. By just pressing a few buttons on the right side of the instrument it is very easy to switch between TV-picture, spectrumand digital mode. In digital mode the MEGALOOK presents digital information as BER (Bit Error Rate), constellation diagram (QPSK and QAM) and S/N (Signal/Noise ratio) for both DIRECTV, cable-tv, digital terrestrial TV and DVB format. The MEGALOOK also has a NIT function which is described below (see the NIT function). 1.2 NIT function NIT is an abbreviation for Network Information Table. NIT is a part of the DVB standard which almost all satellites are using. MEGALOOK can by its NIT function identify a satellite and present its operator and orbital position add in some cases it also presents the name of the adherent TV-and radio channels. 1.3 Memory MEGALOOK can save both spectrum pictures and frequencies (from both digital and analogue transponders). When performing measuring a saved spectrum picture can easily be compared with a spectrum picture from the current measurement. This facilitates an easy identification of the satellite and gives the possibility to check that the received signal level is optimal. MEGALOOK offers the possibility to perform measuring on up to 10 saved frequencies at the same time. These are individually programmed with 13 or 18V and 22 khz on or off. The chosen polarization, 13 or 18V and 22KHz on or off is indicated on the LCD display. The instrument features circuitry protection to prevent short circuits during connection of the LNB. 4

5 1.4 DiSEqC compatibel The DiSEqC-function controls all DiSEqC-accessoires (switches, LNB s etc.). The function is easily implemented and very flexible to use. Note that MEGALOOK can run DiSEqC actuators. It can be set-up for running DiSEqC 1.2 (these are the most common DiSEqC actuators), SatScan (Nokia) and SatSelect (Triax). The MEGALOOK is powered by a built-in, rechargeable battery. The battery is recharged by the either the enclosed battery charger or the car-adaptor. Battery-status is shown on top of the LCD-display (in shape of a battery). Despite all its functions the MEGALOOK is very light and flexible, it only weighs about 7kg including battery and the enclosed carrying-case. DiSEqC is a trademark of EUTELSAT 2. Operation In this section it is described how the instrument is operated. 2.1 Unpacking Start with unpacking the instrument from the carton in which it has been transported and check that besides this manual the following items are included pc MEGALOOK instrument 2. 1 pc Nylon carrying case with shoulder strap 3. 1 pc Power supply 220V/13,5V 4. 1 pc Auto Adapter cord (car charger) 12V 5. 1 pc Adapter BNC-male/F-female 6. 1 pc Adapter BNC-male/IEC-female Keypad Control knob RS232 BNC -TV Control knob Main switch Audio tune & volyme Power plug (DC) BNC -SAT Figure 1. The instrument s control panel. The MEGALOOK s control panel with keypad, control knobs, control button, voltage plug for charging and mains operation and main switch for switching the instrument on or off is shown in figure 1. The instrument also has a RS232 plug that is 5

6 used for connecting the instrument to a computer. Adjustments for contrast, brightness and vertical hold are located under the instrument. 2.2 Connection Use the main switch to turn the instrument on and connect the signal source (SAT or TV) to the BNC plug. After a couple of seconds when the instrument is starting up you will be given the options SAT or TV on the LCD display. Choose the option that corresponds to the signal source that you have connected to the instrument by pressing the keypad, button no.1 for TV and button no.2 for SAT. 2.3 Maintenance MEGALOOK is equipped with a rechargeable battery and it is important that the battery is maintained in a proper way. Recharging should be done with the enclosed car-adaptor (12V) or the power supply (220V/13.5V, 1.7A). Note that the MEGALOOK can be operated by using the enclosed power supply during a short while but not during a long period since the instrument is not made for permanent operation by electric power. When the battery-symbol in the upper right corner of the LCD-display is empty the battery needs to be recharged. Remember that a cold battery has much lower capacity than a warm one. MEGALOOK is designed for outdoor use in rough conditions but it should not be exposed for rain or snow as this can damage or shorten the life span of the instrument Battery check As the MEGALOOK has been stored for some time before transportation it is important to check the condition of the battery. To do this, turn the instrument on with the main switch (see figure 1). When the instrument starts up, the backlighting of the monitor screen and the LCD-display is turned on. A symbol in shape of a battery placed in the upper right corner of the LCD-display shows the status of the battery. All black means that the battery is fully charged. If the symbol is empty it means that the battery is empty too. If the battery needs recharging, use the enclosed power supply (220V/13.5V). When the recharging starts, a thermometerscale indicating the capacity of the battery (0-100%) is shown on the LCD-display. Note! The instrument shall be turned off when being recharged. Recharging a fully discharged battery to about 98% of its capacity takes aproximately 30 hours. When the battery has been recharged, the MEGALOOK is ready to be used. 6

7 3. SAT-TV mode When choosing SAT-TV in the start up menu, the main menu shown in figure 2 will be shown on the LCD display. Figure 2. The main menu in satellite TV mode. Information such as the cursors position (frequency), the start frequency of the spectrum (920MHz), the end frequency of the spectrum (2150 MHz) and the bandwidth (1231 MHz) is shown on the monitor screen. The most important measured data, the db-value, is shown to the right on the monitor screen. The db-value is being updated a couple of times per second. Functions that are controlled by the controlbutton: A few important functions are contolled exclusively by the controlbutton and cannot be controlled by the menusystem on the LCD display. To be able to work with MEGALOOK in a smooth and easy way it is important to learn and remember the functions of the controlbutton in different modes. In SAT mode start by pressing the controlbutton. The setting which is shown on the LCD-display will change from FREQ (frequency) to SPAN (frequency-span) or ZOOM. Another press of the button and the instrument returns to FREQ mode. See spectrum mode in the table below. Spectrum mode: Picture mode: Digital mode: Frecuency Frecuency Frecuency Bandwidth (span) Memory Memory Zoom Table 1. The function of the controlbutton in SAT mode. When the instrument is in frequency mode, the cursor is controlled by the control knob. Move the cursor up/down by turning the control knob left or right. The different functions that can be selected in the main menu in satellite TV mode are described below. 7

8 3.1 Picture mode After having chosen a frequency by placing the cursor on it, it is easy to go to picture mode by choosing picture in the main menu (press button number 1). In picture mode the frequency-position is changed by turning the control knob. If you want to switch between your saved memorypositions push the control button and turn the control knob. Press the control button to return to frequency mode. The chosen function is displayed at the top of the LCD display, for example in figure 2 frequency mode (FREQ) is selected. Measuring on a tuned frequency can be performed in picture mode (the db-value is shown on the LCD-display) Functions in picture mode 1. Invert Press button no. 1 to switch between normal video (KU-band) and inverted video (C-band). The selected mode is shown on the LCD display. 2. Sound Press button no. 2 to listen to analogue audio. Audio volume and frequency ( MHz) are adjusted with the two small knobs that are shown in figure no Memory This function is used to save an analogue or digital frequency. Tune in a frequency according to your choice, for example 1720 MHz and press button no. 3, memory (note that also the current setting of 13V or 18V and 22kHz on or off will be saved). Choose a memory position by turning the control knob (the number of the memoryposition, 0-99, is shown at the bottom of the LCD display) and press button no. 1, save. If the chosen memoryposition is already used for another frequency the text Save are you sure? will be shown on the display. If you want to change the saved frequency press button no. 1, Yes and if not press the the button with the sign, *, No, choose a new memoryposition and save it. Figure 3. Text-editor. Next step is to save the channel with a name, e.g. CNN. This can be done by using the text-editor that is shown on the monitor screen, see figure 3. Choose a character or a symbol by using the control knob and press the control knob to confirm. Repeat the same procedure until you have written the channel name. Use button no. 1, delete, to erase (one character at a time). Press the button with the sign, *, save when you are ready. 4. Atten Press button no. 4 to turn the manual attenuation 15dB function on or off. The selected mode is shown on the LCD display /18V Press button no. 0 to select 13V or 18V. The selected mode is shown on the LCD display. 8

9 #. 22kHz Press the button with the sign # to turn 22 khz on or off. The selected mode is shown on the LCD display. 3.2 Digital mode MEGALOOK can easily perform measuring on digital transponders (MPEG-streams). This kind of measuring serves to control and verify that an installation has been correctly performed (a fingerprint of the installation). It is less suitable to use to find a satellite or to adjust the cross-polarisation. Therefore, start with finding the right satellite by using the spectrum-function. Check and adjust the cross-polarisation with the Max zoom in function. Choose a suitable transponder (put the cursor on the top of a peak ) and select function 2 in the mainmenu (in digital mode). The so called constellation diagram (QPSK) is displayed on the monitor, in the left upper corner. To the right of it, four lock-parameters and a time counter are shown. The time counter will start as soon as a digital bit stream is locked and it will show the lock time. The other measured data like the S/N-ratio (Signal/Noise ratio) and BER (Bit Error Rate) are displayed just under the constellation diagram in the shape of Bar-graph s (thermometer-scales). An example of a locked frequency is shown in figure 4. Figure 4. A locked frequency. The following digital readout is also shown on the monitor screen. Freq: AFC: SR: FEC: CB: UCB: The tuned in frequency. Automatic Frequency Control -the instrument automatically adjust the frequency and tells the offset frequency from center of carrier. Symbol rate. The instrument automatically reads the correct symbol rate of the transmission. Forward Error Correction. The instrument automatically reads the correct FEC. Corrected Bits Bits that have been corrected in Viterbi and will therefore not be seen on the TV. Uncorrected Blocks Blocks unable to be repaired. This will be seen on the TV (in shape of mosaic). 9

10 3.2.1 NIT - Network Information Table As soon as a digital transponder is found the word "searching" will appear on the right side of the picture. If the satellite is transmitting NIT information, the satellite position will appear after about 5-10 seconds (and in some cases also the name of the satellite, e.g. Astra 19.2) Press button no. 4, "Channels" to see a list of the TV- and radio channels on the tuned transponder/frequency (see figure 5). Figure 5. An example of a list of current TV and radio channels on a tuned frequency. When performing digital installations, please notice: The constellation diagram is like a charge of shot. When there is no signal the noise, which is illustrated in the four squares, will be spread out. The better signal, the more concentrated and focused will the charges of shot be. SNR. The Signal/Noise ratio should be as high as possible. A good signal has a S/N-ratio of 8.0 db as a minimum. BER. The Bit Error Rate should be as low as possible. As the values are really small, on the other side of zero (presented as something raised to minus something), the minus value should be as high as possible. - A BER at is therefore better than A BER at is therefore better than It can be said, in general, that a signal should be at least X-04 to be accepted Functions in digital mode 1. Search + Automatic search for the next digital transponder higher in frequency. Returns to the same transponder if no transponder higher in frequency is found. Searching is displayed at the bottom of the monitor screen. 2. Search Automatic search for the next digital transponder lower in frequency. Returns to the same transponder if no transponder lower in frequency is found. Searching is displayed at the bottom of the monitor screen. 3. Memory This function is used to save digital transponders. 10

11 - Tune in a frequency according to your choice, for example 1650 MHz and press button no. 3, memory (note that also the current setting of 13V or 18V and 22kHz on or off will be saved). - Choose a memory position by turning the control knob (the number of the memoryposition, 0-99, is shown at the bottom of the LCD display) and press button no. 1, save. Free positions are designated: pos free. If the chosen memoryposition is already used for another frequency the text Save are you sure? will be shown on the display. - If you want to change the saved frequency press button no. 1, Yes and if not press the the button with the sign, *, No, choose a new memoryposition and save it. Next step is to save the channel with a name, e.g. Digital. This can be done by using the text-editor that is shown on the monitor screen, see figure 3. - Choose a character or a symbol by using the control knob and press the control knob to confirm. Repeat the same procedure until you have written the channel name. - Use button no. 1, delete, to erase (one character at a time). Press the button with the sign, *, save when you are ready. - Load a memoryposition by pushing the control button. The word Memory will appear on top of the LCD and a memoryposition will be shown at the bottom of the LCD-display. - Step between the stored memory-positions with the control knob. 4. Channels Shows a list of the present TV- and radio channels on the tuned transponder/frequency (provided that the satellite is transmitting NIT). 5. DiSEqC Choose between the different DiSEqC commands by using the keypad. Submenu 7 (SWx) shows the extended DiSEqC-commands (DiSEqC 1.1). Submenu 8 (Motor) shows the command-list for DiSEqC actuator-control (DiSEqC 1.2). Also 13V/18V and 22 khz on or off can be adjusted in DiSEqC mode. 7. Beeper It might be tricky to install a satellite dish and, at the same time, try to watch the signal-level on the instrument. Therefore the instrument has a very useful beeper function to help finding the maximum signal strength. It works with a pitch tone that gets higher and higher the better the signal gets. The beeper is turned on or off with button no V/18V Selection of 13V or 18V. The selected choice is shown on the left side at the top of the LCD-display. #. 22kHz 22 khz on or off. The selected choice is shown on the left side at the top of the LCD-display. 3.3 Span Min / Span Max Use this function to switch between full spectrum ( MHz, see figure 6) and Max zoom in (250 MHz bandwidth, see figure 7). By using the Max zoom in function it is easy to adjust the cross-polarisation. 11

12 Figure 6. Full spectrum ( MHz). Move the cursor to a frequency of choice (a peak). Press button no.3 (span Min). The instrument will do a maximum zoom in (250 MHz bandwidth) on the selected frequency. Figure 7. Maximum zoom in (250 MHz bandwidth). Rotate the LNB so that either the horisontal or vertical polarisation will be in its maximum position, in other words; adjust the cross-polarisation. Press button no. 3 again (span Max), to return to Max zoom out. 3.4 X-pol Test the maximum cross-polarisation setting with the X-pol function. The instrument will measure the strength of the selected peak and then automatically switch to the other polarisation and measure there as well (same frequency and settings). The function is useful for checking the correct setting of the LNB cross-polarisation. 3.5 DiSEqC Use the keypad to choose a DiSEqC command. Submenu 7 (SWx) shows the extended DiSEqC 1.1 commands. Submenu 8 (Motor) shows the DiSEqC actuator-control commands (DiSEqC 1.2). Also 13V/18V and 22 khz on or off can be adjusted in DiSEqC mode. 12

13 3.6 Setup This function is used to set up some of the basic functions. 1. LNB L.O. Select the LNBs L.O. (Local Oscillator) for showing the correct LNB frequency. Default setting is button no. 9 (IF). 2. Analog Choose between KU-band (normal video) or C-band (inverted video). 3. Motor Choose the type of actuator to be used; standard DiSEqC 1.2, SatSelect or SATSCAN. 4. Display Submenu units: select db-presentation: dbuv, Dbm or dbmv. Contrast (level) and backlite (on/off) can be set under submenu LCD. 5. AutoOff Choose between the different alternatives of automatic turn-off (timer). 6. Version Shows the serial number of the unit and manufacturing date. 7. Keyclick Keypad sound on or off. 8. TV/SAT Choose if you want SAT or TV to be the default start-up mode (always, without asking). When choosing SAT or TV the instrument will restart in the selected mode. 3.7 Beeper It might be tricky to install a satellite dish and, at the same time, try to watch the signal-level on the instrument. Therefore the instrument has a very useful beeper function to help finding the maximum signal strength. It works with a pitch tone that gets higher and higher the better the signal gets. The beeper is turned on or off with button no. 7. Notice that the function works with a narrow bandwith (one transponder) and not with the full bandwidth. To use the beeper function put the cursor on top of a selected peak (transponder) and align the dish. 3.8 Special functions Special functions. Select this function by pressing button no. 8 in the main menu and then you can choose between the functions described below. 1. Max hold Max hold is an excellent function for observing a certain frequency-range over a longer time period to see if/how temporary signals/disturbances can affect the picture quality. Adjust the frequency-bandwidth (see function 3 span min - span max below) and put the cursor on the frequency (peak) that you wish to observe (see figure 8). Choose the max hold function by pressing button no. 1. The instrument starts to sample all top-values in the shown bandwidth and will only update the presented values if the new measured data has higher db-values than the previous measured data. Turn off the max hold function by pressing button no. 1 (no hold). The measured data can be stored. This procedure is described below; see function 4, memory. 13

14 Figure 8. The cursor placed on a signal peak. 2. Reference cursor MEGALOOK has the capability to perform reference measuring in form of signal and picture-carrier/audio-carrier measuring. Do like this: Select function no. 2 Refmrkr. Tune in a frequency with the cursor (put it on the top of the signal that you wish to measure on). Press button no. 1, ref set, and a new cursor will appear on top of the earlier. Turn the control knob and place the new cursor on another carrier or on the noise-floor. The relation between cursor no. 1 and cursor no. 2 is presented in the lower right hand corner of the monitor screen. Notice that 13/18V and 22 khz on/off can be adjusted in this mode with the 0 and # buttons. 3. Span Min Span Max Push button no. 3 (Span Min) to do a maximum zoom in at the chosen frequency (250 MHz bandwidth). Push button no. 3 again (Span Max) to return to Max zoom out. This function is described in detail under the heading of 3.3, Full spectrum, Max zoom in, Span Min /Span Max. 4. Memory Memory for storing spectrum pictures. This function works the same way as the one described under the heading of 3.9, memory. 6. Attenuator Attenuation 15dB on or off. The selected mode is displayed at the upper right hand side of the monitor screen /18V Adjustment of 13V/18V. The selected mode is displayed at the upper left side of the LCD-display. #. 22 khz Adjustment of 22 khz on/off. The selected mode is displayed at the upper left side of the LCD-display. 14

15 3.9 Memory for storing spectrum pictures All spectrum-pictures can be stored in the MEGALOOK. This is useful since documentation of performed measurements can be used on a later occasion for recognizing/identifying the characteristic spectrum of a satellite. This function is also useful to find and point out faults when performing service work. The Mix-function helps to find and identify already known (and previously stored) satellites by placing a previously memorized spectrum picture as a background on the monitor screen. When the wanted satellite is found its spectrum picture will fit like glove with the stored spectrum picture. To store measured data, do like this: - Choose a spectrum picture and press button no. 9, memory, to store it (note that also the current setting of 13V or 18V and 22kHz on or off will be saved). - Choose a memory position by turning the control knob (the number of the memoryposition, 0-99, is shown at the bottom of the LCD display) and press button no. 2, save. Free positions are designated: pos free. If the chosen memoryposition is already used for another frequency the text Save are you sure? will appear on the display. If you want to change the saved frequency press button no. 1, Yes and if not press the the button with the sign, *, No, choose a new memoryposition and save it. Text-editor: Next step is to save the spectrum picture with a name, e.g. ASTRA 1D. This can be done by using the text-editor that is shown on the monitor screen, see figure 3. Choose a character or a symbol by using the control knob and press the control knob to confirm. Repeat the same procedure until you have written the channel name. Use button no. 1, delete, to erase (one character at a time). Press the button with the sign, *, save when you are ready. Do like this to load a stored spectrum picture: -Choose memory from the main menu (press button no. 9). -Choose a memory position at choice (0-99) with the control knob. -Press button no. 1, load and the chosen spectrum picture will be shown on the monitor screen. -Note that the reference cursor function (ref mrkr) is enabled when a stored memory position is downloaded. To mix a stored spectrum picture with an ongoing measuring, do like this: - Enter the memory function in the mainmenu (see figure no. 2) by pressing button no Select a stored spectrum picture by using the control knob (the chosen position, 00-99, is displayed at the right bottom side of the monitor screen). - Mix the spectrum picture with the ongoing measuring by pushing button no. 4. Turn off the mix-memory function by pushing button no TV mode When choosing TV mode in the start up menu, the main menu shown in figure no. 9 will be shown on the LCD display. On the monitor screen information such as the cursors position (frequency), the start frequency of the spectrum (2.00MHz), the end frequency of the spectrum ( MHz) and the bandwidth ( MHz) are shown. Frequency and channel (CH) are shown for the position where the cursor is placed. A stands for analogue channel and D for digital channel. The current value (in db) of the automatic attenuation ( ATT ) is also shown. 15

16 Figure 9. Information and main menu in spectrum mode. VBW and RBW stand for Video-Bandwidth and Resolution-Bandwidth which is explained later on in this manual. The maybe most important measured data, the db-value, is being updated a couple of times per second. Functions that are controlled by the controlbutton: A few important functions of the MEGALOOK can only be accessed by using the control button and not by using the menu system on the LCD display. Therefore in order to handle the MEGALOOK in an easy way it is important to remember which functions that are solely controlled by control button. When the instrument is set to work in TV mode these are the functions of the control button in spectrum and picture mode: Spectrum mode Frequency Bandwidth(span) Attenuation (atten.) Picture mode Frequency Channel (chan.) Mem pos Table 2. The function of the control button in TV mode. In frequency mode, the cursor is controlled by the control knob. Try to move the cursor up/down by turning the knob left/right. 16

17 4.1 Picture mode Choose a frequency by placing the cursor on it and go to picture mode by choosing picture in the main menu (press button number 1), see figure 9. In picture mode the control knob is used to change the frequency-position. When pushing the control button the function of the control knob changes and instead you can switch channel by turning it. Press the control button again to return to frequency mode. The chosen function is displayed at the top of the LCD display, for example in figure 11 frequency mode (FREQ) is selected. Figure 11. Menu in picture mode. Figure 12. Menu in TV mode. Measuring on a TV-channel is done in picture mode since both TV picture and db-level are shown at the same time TV A more precise check of the picture quality can be done in TV mode (press button no. 1, see figure 11). In TV mode the TV picture is not affected by the measuring filter which is normally enabled (the measuring filter can cause picture disturbances). The menu in TV mode is shown in figure Text Select teletext by pressing button no. 1, text. If the tuned in TV channel transmits teletext information (Ceefax) it will appear on the monitor screen. Select page ( ) by turning the control knob. Press button no. 2 to watch TV picture and teletext at the same time (the teletext becomes transparent). Hidden text can be displayed with button no. 1 (reveal) Sound This version of MEGALOOK can be set for the three most common TV-sound systems in Europe (the distance between the picture-carrier and sound carrier is tuned in). The setting is made by choosing sound from the TV-menu. Select with button 1-3 any of the three versions. 17

18 Manual attenuation The default attenuation setting in TV-mode is automatic attenuation (in spectrum mode the signal is always attenuated manually). This is to make sure that the measuring devices in the instrument are working in the best way. However, under some circumstances, for example when the incoming signal is very strong, it might be better to attenuate manually in order to be able to view/measure on a certain carrier. The manual attenuation is controlled like this in TV mode: - In spectrum mode: push the control button until atten is shown at the top of the LCD-display. - Select a suitable attenuation value by turning the knob (the chosen attenuation value is shown on the monitor screen to the right. - In TV mode: push button no. 4 Man att (manual attenuation) and select a suitable attenuation value with the knob (the chosen attenuation value is shown on the LCD-display). - Return to automatic attenuation by pushing button no. 4 Auto att Beeper It might be tricky to install/align a TV antenna and at the same time try to watch the signal level meter on the instrument. Therefore MEGALOOK has a very useful beeper function to help finding the maximum signal strength. It works with a pitch tone that gets higher and higher the better the TV signal gets. The beeper is turned on or off with button no Manual attenuation The manual attenuation is controlled like this in picture mode: - Push button no. 4 Man att (manual attenuation) and select a suitable attenuation value with the knob (the chosen attenuation value is shown on the LCD-display). - Return to automatic attenuation by pushing button no. 4 Auto att. For more information see Memory Choose memory with button no.5. In this mode you can save or delete a memory position for a channel or a frequency. With the control button you can switch between mem pos, frequency and channel mode. Choose a memory position in mem pos mode by turning the control knob. Press the control button to go to frequency mode where you can save or erase a frequency or go to channel mode where you can save/erase a channel. Browse through the saved frequencies/channels in freq /channel mode by turning the control knob Ext A/V An external video and audio signal can be presented on the MEGALOOK (e.g. TV-signals from a head-end). Connect the video/audio signals via the phono-jacks on the side of the instrument and press button no. 6 Ext A/V (in picture mode). 4.2 Digital mode In digital mode you can choose if you want to measure on cable TV or terrestial TV signals. See figure

19 Figure 13. Menu in digital mode Cable When choosing the cable function for measuring on a cable TV signal you will find the following information on the monitor screen: Locking; if the signal is locked and the lock time. Eb/N 0 -value. CB Corrected Bits. UCB Uncorrected Blocks. BER (Bit Error Rate)-value. Constellation diagram. Figure 14. Information and menu in cable TV mode. Available settings in cable TV mode: Zoom zoom in the constellation diagram by using button no. 2. Frequency change by turning the control knob. Modulation change by change by pressing button no. 4. Symbol rate change by pressing button no

20 Channels Press button no. 1, channels, to see information about which TV channels that are transmitted on the tuned frequency. Figure 15. A list of current TV channels Zoom IQ Press button no. 2 to zoom in the IQ constellation Span 13 - Put the cursor on a signal peak of your choice and press button no.3 (span 13) to do a maximum zoom in on the chosen frequency (13Mhz bandwidth). - Press button no. 3, span 900, to return to the original (full) bandwidth. - Use the * button (exit) to go back in the menu system. - To centre the chosen signal peak on the picture screen press button no.5 (center). You can always adjust the bandwidth in spectrum mode by using the span function. Press the control button to enter span mode. In span mode you can set the bandwidth by tuning the control knob. The starting point for the zoom in is the cursors position on the spectrum picture and the bandwidth is reduced from both ends so to say. The most narrow bandwidth is 13 MHz (maximum zoom in) and full bandwidth is 900 MHz Modulation To enter modulation mode press button no. 4. The modulation values to choose between will be shown on the LCD display. Choose a modulation value by pressing the correspondent numerical button: Button no. 1 Button no. 2 Button no. 3 Button no. 4 Button no. 5 QAM16 QAM32 QAM64 QAM128 QAM256 Figure 16. Modulation mode. 20

21 Symbol rate To change the symbol rate press button no. 4, sym rate and turn the control knob (possible values are: ). In the menu (see figure no. 17) you can choose between coarse (button no.1) and fine (button no.2). Figure 17. Symbol rate mode Terrestrial When choosing the terrestrial function, terrest, from the menu in digital mode (see figure no. 13) for measuring on a terrestrial TV signal, the following information will be displayed on the monitor screen (see also figure 18): Locking: if the signal is locked and the lock time. Modulation: the current modulation. Eb/N 0 -value. CB- Corrected Bits. UCB- Uncorrected Bits. BER (Bit Error Rate)-value Constellation diagram Figure 18. Information and menu in terrestrial mode Available settings in terrestrial TV mode: Channel/frequency change by turning the control knob. Switch between channel and frequency with the control button (channel is the default setting). Zoom in the constellation diagram by pressing button no. 2, zoom IQ. Press the button again to return to the previous mode. 21

22 Channels Press button no. 3, channels, to see information about which TV channels that are transmitted on the tuned frequency. Figure 19. A list of current TV channels Zoom IQ Press button no. 2 to zoom in the IQ constellation Span 13 See 4.3 below. 4.3 Span 13 - Put the cursor on a signal peak of your choice and press button no.3 (span 13) to do a maximum zoom in on the chosen frequency (13Mhz bandwidth). - Press button no. 3, span 900, to return to the original (full) bandwidth. You can always adjust the bandwidth in spectrum mode by using the span function. Press the control button to enter span mode. In span mode you can set the bandwidth by tuning the control knob. The starting point for the zoom in is the cursors position on the spectrum picture and the bandwidth is reduced from both ends so to say. The most narrow bandwidth is 13 MHz (maximum zoom in) and full bandwidth is 900 MHz. 4.4 Max hold Max hold is an excellent function for observing a certain frequency-range over a longer time period to see if/how temporary signals/disturbances can affect the picture quality. Choose a frequency-bandwidth (see section 3.3) and put the cursor on the frequency (peak) that you wish to observe (see figure 20). Choose the max hold function by pressing button no. 6. The instrument starts to sample all top-values in the selected bandwidth and will only update the presented values if the new measured data has higher db-values than the previous measured data. The measured data can be stored and transfered to a computer. This procedure is described in section

23 Figure 20. The cursor placed on a frequency (peak). 4.5 Center To centre the chosen signal peak on the picture screen press button no.5 (center). 4.6 Set up MEGALOOK can be set up according to your individual needs and to do special kinds of measurings. These settings are done in the Set up menu. Press button no. 6 to choose set up. The following parameters can be adjusted: Button no. 1 Video Bandwidth ( Vid BW ) - videofilter. The videofilter is situated after the measuring chip-set inside the instrument and is used for presenting the frequency-spectrum at varying resolutions. The resolution of the details of a signal-carrier gets finer the more narrow the filter being used (but in return the sweep-time gets longer). The available videofilters/settings are: auto-mode (default), 100 khz, 10 khz, 1 khz or 100 Hz. Button no. 2 Resolution Bandwidth ( Res BW ). The resolution bandwidth shows the incoming signal before the measuring chip-set in the instrument. Choose between the narrow 300 khz or the wider 1 MHz resolution. The default setting of the instrument is auto mode. Button no. 3 Power insert ( P-insert ). This function is used to run external active accessories (like antenna-amplifiers) which needs a powersource to operate. The output voltage can be adjusted between volt DC and is fed via the BNC plug. The chosen output voltage is always shown in upper left hand of the LCD-display (next to the batterysymbol). The default setting of the instrument is power-off (0 volt). Remember that miss-use of this function may cause irreparable damage to all connected equipment that is not made to be power-fed! Button no. 4 Set up, with the following sub-menu: 23

24 Button no. 1 ( Lcd ) LCD contrast and backlite (on/off) can be adjusted. Button no. 2 ( S-saver ) Screen-saver on/off. The default setting is on. Button no. 3 ( Display ) Display with the following sub-menu: Button no. 1, ( S-cursor ) Button no. 2, ( Grat. ) Button no. 3, ( Units ). Button no. 4, ( TV level ) Scan-cursor. Shows how fast the instrument scans a selected frequencyband. Try this function with different videofilters (see button no. 1 above) and you will notice a difference. The default setting is off. Grating. Shows a grating-net which under some circumstances can facilitate the readout of the signal level. The default setting is off. Units. Choose between signal strenght readout in dbuv, dbm or dbmv. TV level. Shows the level which the automatic attenuation uses for the picturepresentation of the signal (should be between db). Button no. 4 ( Version ) Button no. 5 ( CH-table ) Version. Shows e.g. the instrument s serial number, date of manufacture, softwareversion etc. CH-Table. Choose between different (countries) channel-plans. Button no. 5 FM/AM cursor ( FM mrkr ). Choose between FM or AM cursor. FM = Normal spectrum measuring. AM = Peak spectrum measuring (preferred when measuring on TV-signals since it faster detects the maximum value). Button no. 6 SAT/TV Choose if you want SAT or TV to be the default start-up mode (always, without asking). When choosing SAT or TV the instrument will restart in the selected mode. Button no. 7 CAB/TER In this mode you can choose to automatically enter cable mode ( cable ) or terrestrial mode ( terrest ) or if you always want to be given the option to choose between cable and terrestrial TV ( ask me ) when entering digital mode (see 4.2). 4.7 Reference cursor MEGALOOK has the capability to perform reference measuring in form of signal and picture-carrier/audio-carrier measuring. Do like this: Place the cursor on a signal peak and zoom in by pressing button no. 3, span 13. Select function no. 7, Refmrkr. Tune in a frequency with the cursor (put it on the top of the signal that you wish to measure on) Press button no. 1, ref set, and a new cursor will appear on top of the previous one. Turn the control knob and place the new cursor on another carrier or on the noise-floor. The relation between cursor no. 1 and cursor no. 2 is presented in the lower right hand corner of the monitor screen. 24

25 Figure no. 21. Reference measuring. 4.8 User Span MEGALOOK is normally working with the whole frequency-range of MHz (this is the default mode). This overview over the whole spectrum makes it easy to find all signals within the mentioned bandwidth. In many cases, however, it might be better to divide the frequency-spectrum in the working-areas in which installations and service work are normally being done (e.g. the returnpath, FM, UHF etc.). These working-areas might vary a lot depending on where (geographically) the instruments are being used or by whom. For that reason the MEGALOOK has the unique possibility to do a individual setup of such frequency-bands. Programming of individual frequency-bands is done like this: - Put the cursor approximately in the centre of the frequency-band that you want to programme (e.g MHz). - Press the control button so that Span (bandwidth) is lit on top of the LCD-display. - Turn the knob until the wanted frequency-band (2-65 MHz) is shown in the picture-screen. Note! It might be a bit tricky to exactly tune in the wanted frequency-band, it is sometimes necessary to switch between Freq and Span a couple of times and also use the zoom in function span13. It is, however, well spent time since the programming is only needed to be done once thereafter the frequency-bands are permanently programmed (until chosen to be deleted). - When the wanted frequency-band is tuned in, push the Memory -button (no. 9). - Push button no. 2 Usr span and thereafter the Save -button (no. 1). - Choose a memory position by pressing the correspondent numerical button (e.g. no. 1). The chosen frequency-area is shown at the chosen memoryposition on the LCD-display. - Repeat the above steps to memorize more frequency-bands (up to 8 bands). To retrieve a programmed frequency-band do like this: * Choose Usr span (user span) from the main-menu (button no. 8). * Choose any of the previously programmed frequency-bands from the list by pressing the correspondent numerical button. 25

26 Figure 22. A list of programmed frequency bands. 4.9 Memory All spectrum pictures can be saved in MEGALOOK. This is useful since new installations, service and maintance work can be documented. The memory positions can easily be transfered to a personal computer (PC) by using the enclosed PCsoftware and also printed on a normal PC printer. To save measured data, do like this: - Tune in a spectrum picture of your choice and push button no. 9, memory (see menu in figure 9). - Push button no. 1 spectrum (the function of usr span, button no. 2 is explained in section 4.8). - Choose a memory position for the spectrum picture by turning the control knob (00-99). The selected position is shown at the right bottom side on the monitor screen. - Push the save -button (no. 1) and the memory position is saved. To load saved data (memory positions), do like this: - Choose, memory from the main menu by pressing button no Choose spectrum (button no. 1). - Choose the memory position you want to retrieve by turning the control knob. The position is shown at the right bottom side on the monitor screen. - Push the load button (no. 2) and the memory position is retrieved and shown on the monitor screen Channelpower MEGALOOK can measure, so called, digital db, i.e. the output-level of digital transponders (for instance digital terrestrial transmissions). Simply input the start and stop frequencies of the transponder to measure on (a digital transponder is normally 8 MHz wide) and the measured and corrected output-level (dbµv) will be presented in the bottom right-hand corner of the monitor screen. Do like this: - Put the cursor on a digital signal peak and zoom in with the span 13 button (no. 3 in the main menu). If needed, increase the shown bandwidth with the span -function. Choose span mode by pressing the control button and increase the bandwidth by turning the control knob. When the bandwidth is set, return to frequency mode by pressing the control button twice. - Push button no. 0, channelpower. 26

27 - Tune in the start frequency with the control knob (so the cursor stands in the beginning of the digital transponder to measure on). - Push button no. 1 ( set strt ) and a new cursor appears on top of the earlier. - Turn the knob and place the new cursor at the end of the digital transponder (stop frequency). The measured result (and the adjusted bandwidth BW) is shown in the bottom right-hand corner of screen. the monitor Figure no. 23. Measuring of a digital transponder. 5. PC-software A CD rom with PC software is enclosed with the MEGALOOK. The software is used for the transfering of files (memorypositions) from the instrument to a personal computer. It also offers the possibility to add information (e.g. address information) to the performed measurements. In this way they can also be printed if you have a printer connected to your computer. Installation: The programme (software) can be used by all computers operated with Windows (minimum requirement is Win 95) and is easily installed from the enclosed CD rom (or downloaded from Place the file.exe in a directory of your choice (might be on your desktop). Done! Operation: The instrument must be connected to the computer in order for the programme to work. This is because the computer (and software) continuously communicates with the instrument and scans the instrument s memory positions. To transfer data from the instrument to a computer, do like this: Connect the MEGALOOK to a computer with the enclosed PC-cable to any free com-port. (the cable is a strait malefemale 9-pin dsub). Turn on the MEGALOOK. Make a double-click on the.exe file. 27

28 The software will thereafter automatically find the com-port to which the instrument is connected to. The screen picture below will appear on the PC-monitor. Figure no.24. Screen picture, PC software. Note! The PC-software will not run if the communication between the PC and the instrument doesn t work. If there should be any problem, check the connection and try again. Choose if you want to communicate with the SAT or TV part of the instrument. There are two menus in the upper left hand corner to choose between: Update: is used for updating the memory-list if you have saved a new spectrum after starting the programme. Comport: is used if the connection has failed and you want to try connecting again without restarting the programme. Retrieving memory positions: As shown above there is a list of the memories where you can select one for viewing. If the list is empty you have to save a spectrum-memory in your MEGALOOK. Mark the memory-position you want to transfer to the PC, for example Spec-Memory 01 by using the PC-mouse. The memory-position is transfered and the result can be viewed on the PC-monitor. The picture can be viewed more in detail with the zoom in function. This is done by pushing down the shift -button and at the same time draw a box with the PC-mouse around the area to enlarge. To zoom out, simply push down the shift -button and click with the PC-mouse in the enlarged area. Print-outs/documentation: There are three menus in the view-window s upper left hand corner: Copy, View and Help. Push Copy and the picture is being copied to clipboard. View lets you change the look of the window. Help gives you a brief description of how to zoom and pan. Without closing the programme, start another programme, a suitable word-processing programme (like Word) and open a new document. Push the paste-button and the picture (memory position) is inserted to the document. The picture below shows such an example. 28

29 Memory:00 ASTRA 19.2 LNB:13V The instrument programme makes it very easy to transfer memory-positions to a PC and make good looking - professional documentation. After finishing work, close the programme and don t forget to turn the instrument off. 6. Firmware upgrade To do a firmware upgrade do like this: Download the firmware and save it on your PC. Connect the RS 232 cable from the instrument to your PC. Turn on the instrument. The firmware is zipped and you need to un-zip the file. There is one.hex file and one FDL-program (Firmware downloader). Start the loader by double click the FDL-program. Select the COM port that you have inserted the RS-232 cable. It will now search for the instrument. When it have found the instrument, turn the instrument OFF and plug in the external power supply. Press Send firmware. Select the.hex file that you want to use in the Open firmware file window that now appears on your PC. It will now download the firmware. You will see the progress on your PC, do not remove the power supply! The download is finished when the counter has reached 100%. You have now downloaded the new firmware to your instrument. 29

30 7. Technical specification Common data: Presentation of signal level (analogue): TV standard: Input impedance: Picture screen: db on LCD/monitor screen. Pitch-tone. Multi TV/ (PAL, NTSC). 75 Ohm, BNC-con monitor, B/W. Menus: On LCD 64x128. Memory: Favorite channels: PC-connection: Battery: Accessories: Weight: spectrum pictures can be stored with name. Saved spectrum pictures can be mixed with an on-going measuring for an easy identification. - Maxhold function. Both analogue and digital frequencies can be memorized and stored with name. RS232-output. Re-chargeable 12V, 7 amp/hour. Nylon carrying-case. Power-supply of 220V/13.5V, 1.7amp. Car-charger, BNC/F-adapters. 7.5 kg. SAT-part: Input frequency: Min. level in: Max. level in: Attenuation: Accuracy: Presentation of signal level (digital): Satellite identification: KU-C-band: Sat-TV power out: DiSEqC DiSEqC motor: MHz. Approx. 35 dbµv (noise). Approx. 90 dbµv. 15 db attenuator on/off. ± 2 db (at +20 C). S/N (Signal/Noise-ratio). BER (Bit Error Rate). Constellation (QPSK). Yes, NIT- reading according to DVB-standard. Identifies satellite position, TV and radio channels. Yes selectable V. 1.0, 1.1 and Toneburst on/off. Built in positioner for DiSEqC 1.2, SatScan and SatSelect. 30

COMBOLOOK. Manual English. Version: 2.00

COMBOLOOK. Manual English. Version: 2.00 COMBOLOOK Manual English Version: 2.00 1 Owner's Manual Thank You for purchasing a Emitor AB COMBOLOOK-instrument. This manual covers the operation and maintenance of the Emitor AB COMBOLOOKinstrument

More information

Owner's Manual. All information in this publication is based on the latest product information available at the time of printing.

Owner's Manual. All information in this publication is based on the latest product information available at the time of printing. STARLOOK- D Manual You are entitled to the manufacturer's limited express warranty, if any, that accompanies the product. DAWNco makes no additional or independent warranty. All other warranties, express

More information

Combolook Color HD User Manual

Combolook Color HD User Manual Combolook Color HD User Manual Sjöviksbacken 14, 4 tr SE-117 43 Stockholm, Sweden Phone: +46 (0)8 775 00 01 Fax: +46 (0)8 775 00 06 www.emitor.se Thank You for purchasing the Emitor AB Combolook Color

More information

DIGISAT MULTI USER MANUAL

DIGISAT MULTI USER MANUAL DIGISAT MULTI USER MANUAL CONTENTS: Meter specifications page 3 Accessories included page 3 Description page 4 Charging the batteries page 5 Controls and Features page 6 Hi Resolution Mode page 7 Audio

More information

Horizon HD-STM. Combo Signal Analyzer TEST REPORT

Horizon HD-STM. Combo Signal Analyzer TEST REPORT TEST REPORT Combo Signal Analyzer Horizon HD-STM can be used intuitively, manual is not needed perfect workmanship optimized for the day-to-day work of an installer gives all the "Must-Have" informations

More information

Emitor International AB Ostmastargrand 12 SE Stockholm, Sweden Phone: +46 (0) Fax: +46 (0)

Emitor International AB Ostmastargrand 12 SE Stockholm, Sweden Phone: +46 (0) Fax: +46 (0) Emitor International AB Ostmastargrand 12 SE-120 40 Stockholm, Sweden Phone: +46 (0)8 5333 40 70 Fax: +46 (0)8 5333 40 71 www.emitor.se Thank You for purchasing the Emitor International AB Combolook Color

More information

Super Installer Lite USER MANUAL

Super Installer Lite USER MANUAL Super Installer Lite USER MANUAL Contents Super Installer Lite - Description..... page 3 Getting Started........ page 4 Power On/Off Power Supply and Battery How to use the meter Menu.......... page 7

More information

Xsarius Satmeter Pro. Manual

Xsarius Satmeter Pro. Manual Xsarius Satmeter Pro Manual 1 2 Directory of content Introduction Directory of content 3 Introduction 3 Satmeter Pro 02 Frontpanel & buttons 6 Xsarius provides high quality products that enable you to

More information

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE.

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE. STM 17 HD DVB-S2+T2/C Compact Meter User Manual Ref 0145131R13 DVB COMBO METER 1. Main Features... 2 2. Buttons and Indicators... 3 3. How to measure... 4 4. Home menu... 5 5. Satellite... 5 5.1 Satellite

More information

PCM-1210 DVB COMBO METER User`s Manual

PCM-1210 DVB COMBO METER User`s Manual PCM-1210 DVB COMBO METER User`s Manual 1. Main Features... 1 2. Buttons and Indicators... 2 3. How to measure... 3 4. Home menu... 4 5. Satellite... 4 5.1 Satellite Measure... 4 5.2 LNB Setting... 5 5.3

More information

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual GENERAL FEATURES Easy-to-understand user-friendly menu and keypad. LNB short circuit protection. Display of Analog Signal Level, Digital Signal Quality with % and Bar, audible notification. Timer Lock,

More information

HD RANGER+ Evolution? NO. Revolution!

HD RANGER+ Evolution? NO. Revolution! Evolution? NO. Revolution! The SIXTH GENERATION field meter FROM PROMAX lite ACTUAL SIZE - 7 SCREEN (APPROX. 155 x 93 mm) Revolutionising the market. Again The largest and brightest display HD RANGER+

More information

Digital Terrestrial Alignment & Installation Meter

Digital Terrestrial Alignment & Installation Meter Digital Terrestrial Alignment & Installation Meter Instruction Booklet Version 3 - February 2005 www.horizonhge.com Thank you for choosing our latest and most innovative terrestrial meter. It has been

More information

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER C/N FEC dbuv VITERBI REED-SOLOMON DVB MPEG-2 QPSK BER FEC QPSK C/N FEC dbuv VITERBIREED-SOLOMON DVB MPEG- 2 QPSK BER C/N FEC dbuv VITERBI REED- SOLOMON DVB MPEG QPSK C/N FEC dbuv VITERBI REED-SOLOMON DVB

More information

Satellite locator WS-6933

Satellite locator WS-6933 R Satellite locator WS-6933 User's Manual English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW&ILLUSTRATION...3 2. OUTLINE...4 3. THE MENU OSD INSTRUCTION...5

More information

Owner s Manual. Sat-Meter MSK 15. Order No.:

Owner s Manual. Sat-Meter MSK 15. Order No.: Owner s Manual Sat-Meter MSK 15 Order No.: 217 100 13 Thank you for choosing our latest and most innovative satellite meter. It has been designed and manufactured to a very high standard and offers a UNIQUE

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

REVOLUTIONISING THE MARKET. AGAIN

REVOLUTIONISING THE MARKET. AGAIN REVOLUTIONISING THE MARKET. AGAIN ACTUAL SIZE - 7 SCREEN (APPROX. 155 x 93 mm) The largest and brightest display HD RANGER+ 7 display is the brightest and largest used in any similar meter with excellent

More information

SATELLITE FINDER SK-3200 USER MANUAL

SATELLITE FINDER SK-3200 USER MANUAL SATELLITE FINDER SK-3200 USER MANUAL CONTENTS 1. GUIDE...1 1.1 IMPORTANT SAFETY INSTRUCTIONS... 1 1.2 UNPACKING...1 1.3 PRODUCT OVERVIEW & ILLUSTRATION... 2 2. OUTLINE...4 3. THE MENU OSD INSTRUCTION...5

More information

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview Dual Satellite Tracking Meter 38.8 With a built in Khz tone generator Specifications Power demand over 800 ma will result in an Over Current indication. Compatible With STARBAND Receivers Input Frequency:

More information

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica AVE HOME CVBS TO DVB-T ENCODER MODULATOR FAGOR Fagor Electr6nica TABLE OF CONTENTS 1. SPECIFICATIONS... 12 1.1 Product Overview... 12 1.2 Appearance and Description... 12 1.3 Diagram... 13 1.4 Characteristics...

More information

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual ATLANTA ASF 2033HD+ DVB-S/S2 METER User`s Manual Buttons and Indicators... 2 How to measure... 3 Main menu... 4 LNB Setting... 4 Edit Satellite... 6 Spectrum Chart... 7 Constellation... 9 Angle Calculation...

More information

SATFINDER 3 HD SLIM USER GUIDE

SATFINDER 3 HD SLIM USER GUIDE SATFINDER 3 HD SLIM USER GUIDE INDEX General Safety..... 3 Key Features..... 4 Panel Keypads... 5 Accesory.. 6 Satellite Search...... 7 Spectrum..... 8 Cross Polarisation... 9 Packet TP Levels.... 9 Multi

More information

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4. DTM-HD01 Thank you for buying this encoder modulator. Please read this manual carefully to install, use and maintain the encoder modulator in the best conditions of performance. Keep this manual for future

More information

XR-3 QAM 8VSB. Modular Test Instrument. XR-3 Rugged Adaptable Economically Efficient Configurable to test: and more

XR-3 QAM 8VSB. Modular Test Instrument. XR-3 Rugged Adaptable Economically Efficient Configurable to test: and more XR-3 Modular Test Instrument XR-3 Rugged Adaptable Economically Efficient Configurable to test: and more QAM 8VSB XR-3 Modular Test Instrument GENERAL FEATURES Durable case with rubber shock guards Color

More information

Subject : Using the TV meter for a terrestrial installation NASE786X-04-03

Subject : Using the TV meter for a terrestrial installation NASE786X-04-03 Subject : Using the TV meter for a terrestrial installation NASE786X-04-03 SEFRAM 7861 7862 7861HD 7862HD field strength meters enable the configuration of a terrestrial or satellite TV reception system.

More information

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide S7000 TV & Satellite Analyzer Key Features All standards in one: QAM(J.83A/B/C), 8VSB, DVB-T/H/T2, DVB-S/ S2 Digital/Analog TV and Satellite TV analysis MPEG2 Transport stream analyzer and monitoring via

More information

SZU OPERATING INSTRUCTIONS SAT NAVI

SZU OPERATING INSTRUCTIONS SAT NAVI SZU 21-00 O P ER ATI N G I N S T R U C T I O N S SAT NAVI Operation Instructions SZU 21-00 Safety Notes Turn off the receiver or any used power supply before installing, to avoid short-circuit. Installation

More information

HD-CM HORIZON DIGITAL CABLE METER

HD-CM HORIZON DIGITAL CABLE METER HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279

More information

MyM-3S Micro Master. Installation Guide. English. design for TV

MyM-3S Micro Master. Installation Guide. English. design for TV MyM-3S Micro Master Installation Guide design for TV 1 CONTENT 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. IP settings 5. Menus and settings 5.1 Overview menu 5.2 Input settings

More information

HD RANGER. The PROMAX. 50 SE 50 years edition. Evolution? NO. Revolution! SIXTH GENERATION. field meter FROM

HD RANGER. The PROMAX. 50 SE 50 years edition. Evolution? NO. Revolution! SIXTH GENERATION. field meter FROM HD RANGER Evolution? NO. Revolution! 50 SE 50 years edition The SIXTH GENERATION field meter FROM PROMAX ACTUAL SIZE - 7 SCREEN (APPROX. 155 x 93 mm) Revolutionising the market. Again The largest and brightest

More information

Advanced HDTV System Analyzers

Advanced HDTV System Analyzers H45 FIRST HANDHELD System Analyzer WITH DIGITAL PROCESSING Advance SERIES Advanced HDTV System Analyzers HDTV testing made simple - One single tool covers every testing need MPEG-4 FULL HD 1080P CABLE

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

Horizon Global Electronics Ltd.

Horizon Global Electronics Ltd. Horizon Global Electronics Ltd. First Floor Office Allen House Edinburgh Way Harlow Essex CM20 2HJ Phone: +44(0) 1279 417005 Fax: +44(0) 1279 417025 Issue No.??123/0.1 Horizon Part Number:??123 Copyright

More information

User s Manual of Signal Level Meter TABLE OF CONTENTS

User s Manual of Signal Level Meter TABLE OF CONTENTS TABLE OF CONTENTS A OVERVIEW OF SIGNAL LEVEL METER...2 B FEATURES OF SIGNAL LEVEL METER...2 C PRECAUTIONS...2 D PANEL AND LCD...3 E INSTRUCTIONS OF KEYS...3 1. SINGLE-CHANNEL MEASUREMENT...4 2. SINGLE-FREQUENCY

More information

HD-TM PLUS HORIZON DIGITAL TERRESTRIAL METER

HD-TM PLUS HORIZON DIGITAL TERRESTRIAL METER HD-TM PLUS OFF MENU INPUT ON HORIZON DIGITAL TERRESTRIAL METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279 417005 Fax: +44(0) 1279 417025 Issue

More information

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz Broadcast Product Brochure 02.00 R&S ETH Handheld TV Analyzer At a glance The R&S ETH handheld TV analyzer was specially designed

More information

DIGITAL SATELLITE METER

DIGITAL SATELLITE METER DIGITAL SATELLITE METER THE PROFESSIONAL EQUIPMENT DIGITAL SATELLITE METER THE PROFESSIONAL EQUIPMENT USER S MANUAL Product Description 1.Guide 2. Menu 1.1 Face Panel & Button 1.2 Power On/Off 1.3Power

More information

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE CONTENTS : General Safety...... 3 Basic Properties.... 4 Front Panel Keys... 5 Back Panel Details 5 Charger Adapters.. 6 Utilization of Satfinder4......

More information

Sunrise Telecom, Hukk Division

Sunrise Telecom, Hukk Division Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Sunrise Telecom, Hukk Division CR1200R Manual Contents (Rev. B) CHAPTER 1 - GENERAL INFORMATION A general description

More information

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s 120531 M5-H002 Multiview T-35 DVB-T to PAL / 5 channels on all TV s Contents Multiview... 3 Features... 3 Caution... 3 Front & Rear Panel... 4 Connecting... 5 Programming... 6 Information... 7 Installation...8

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

ASF 2050 COMBO USER MANUAL

ASF 2050 COMBO USER MANUAL ASF 2050 COMBO USER ASF 2050 COMBO USER 1. BUTTONS AND INDICATORS... 2 2. BASIC FUNCTIONS.... 4 2.1 Satellite... 5 2.2Terrestrial... 24 2.3 Cable... 33 2.4 Saving... 41 2.5 System Setting... 42 2.6 USB

More information

TDH 700 Main and sub unit for digital headend

TDH 700 Main and sub unit for digital headend TDH 700 Main and sub unit for digital headend Technical data Part No. TDH 700 Main unit 490790 TDH 701 Sub unit 490791 TDH 791 Stand-alone cabinet 301791 TDH 700 Stand-alone controller 301700 Number of

More information

RANGERNeo + TV, CABLE, SATELLITE & WIFI ANALYSER HEVC H.265 EASY OPERATION WIFI ANALYSER WIDEBAND LNB A NEW STANDARD IN FIELD STRENGTH METERS

RANGERNeo + TV, CABLE, SATELLITE & WIFI ANALYSER HEVC H.265 EASY OPERATION WIFI ANALYSER WIDEBAND LNB A NEW STANDARD IN FIELD STRENGTH METERS A NEW STANDARD IN FIELD STRENGTH METERS TV, CABLE, SATELLITE & WIFI ANALYSER RANGERNeo + EASY OPERATION HEVC H.265 WIFI ANALYSER WIDEBAND LNB Hybrid user interface (touch + keyboard) High Efficiency Video

More information

MANUAL ENG DT-1600 ENGLISH. Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK

MANUAL ENG DT-1600 ENGLISH. Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK ENG-1 030206 01261-3 ENGLISH Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK A versatile digital receiver with a guaranteed future has been developed to transmit

More information

Television Analyser - TVA97

Television Analyser - TVA97 Television Analyser - TVA97 Multi-functional instrument for RF applications setting the pace in professional RF technology summary setting the pace in professional RF technology Feature Frequency, Gain

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION...17

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION...17 USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

Operating Manual. DVB-T Meter MFK 16

Operating Manual. DVB-T Meter MFK 16 Operating Manual DVB-T Meter MFK 16 Preface Dear customer, KATHREIN-Werke KG has made every effort to ensure the accuracy and completeness of this manual. However, no liability can be accepted for potential

More information

ST-4000 SIGNAL LEVEL METER

ST-4000 SIGNAL LEVEL METER ST-4000 SIGNAL LEVEL METER Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter.... 3 Quick Use Instructions.. 3 Main

More information

MTD 120. (Color) Ref BER. (Bit Error Rate) TV & SAT Level Meter. User s manual

MTD 120. (Color) Ref BER. (Bit Error Rate) TV & SAT Level Meter. User s manual MTD 120 Ref. 4202 Ref. 4207 (Color) (B/N)-- BER (Bit Error Rate) TV & SAT Level Meter User s manual INDEX... Page 1.- GENERAL... 105 1.1.- Description... 105 1.2.- Specifications... 106 2.- SAFETY RULES...

More information

Horizon Global Electronics Ltd.

Horizon Global Electronics Ltd. Horizon Global Electronics Ltd. First Floor Office Allen House Edinburgh Way Harlow Essex CM20 2HJ Phone: +44(0) 1279 417005 Fax: +44(0) 1279 417025 Issue No.??123/0.1 Horizon Part Number:??123 Copyright

More information

Super Buddy Operation Manual

Super Buddy Operation Manual Operation Manual Revision 2.00 Date 10/23/2007 1. INTRODUCTION...4 CONNECTIONS... 4 IRD CONNECTION... 5 PC CONNECTION... 5 2. RUN SCREEN...5 DISPLAYED DATA... 5 SOFT KEYS... 6 CHANGING SATELLITES... 6

More information

SM-10 SAT Level Meter User s Manual

SM-10 SAT Level Meter User s Manual SM-10 SAT Level Meter User s Manual DAGATRONICS CORPORATION 263-1 DUCKIDONG, ILSAN, KOYANG, KYUNGKIDO, KOREA TEL: +82-31-916-8005 FAX: +82-31-916-8080 Email: dagatron@dagatron.com Website: www.dagatron.com

More information

1. GUIDE Important Safety Instructions Unpacking PRODUCT OVERVIEW&ILLUSTRATION INSTALLATION OFMETER

1. GUIDE Important Safety Instructions Unpacking PRODUCT OVERVIEW&ILLUSTRATION INSTALLATION OFMETER 1. GUIDE... 3 1.1 Important Safety Instructions... 3 1.2 Unpacking... 3 1.3 PRODUCT OVERVIEW&ILLUSTRATION... 4 1.4 INSTALLATION OFMETER... 6 2. OUTLINE... 6 3. THE MENU OSD INSTRUCTION... 7 3.1 DVB S2...

More information

860 DSP Digital Field Analyzer

860 DSP Digital Field Analyzer DSP Technology Allows for Quick, Accurate Level Measurements Measures Signal Levels in the 5 to 870 MHz Frequency QPSK and QAM Measurements, High-Resolution Spectrum Analyzer, and Reverse Path Tester Adaptable

More information

DIVERSITY DVB-T RECEIVER (DDR)

DIVERSITY DVB-T RECEIVER (DDR) User s Manual The most important thing we build is trust. DIVERSITY DVB-T RECEIVER (DDR) Cobham Surveillance GMS Products 1916 Palomar Oaks Way Ste 100 Carlsbad, CA 92008 100-M0062X2 T: 760-496-0055 05/15/09

More information

TABLE OF CONTENTS. 1 GENERAL Description Specifications...3

TABLE OF CONTENTS. 1 GENERAL Description Specifications...3 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER S MANUAL. PROLINK-2 Premium TABLE OF CONTENTS 1 GENERAL...1 1.1 Description...1 1.2 Specifications...3 2 SAFETY RULES...9

More information

STM 26 HD. DVB-S2+T2/C Compact meter User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE

STM 26 HD. DVB-S2+T2/C Compact meter User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE STM 26 HD DVB-S2+T2/C Compact meter User Manual Ref 0145225R13 Preface USER MANUAL Please read this manual carefully before using your Digital Sat meter for the first time. This operating manual will help

More information

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

Ultra-ViewRF 8HD Director Monitor. User Operation Manual Ultra-ViewRF 8HD 5.8GHz Wireless Director Monitor User Operation Manual 17.1.2013 v2_7 Video Equipment Rentals - VER 912 Ruberta Avenue Glendale, CA 91201 - U.S.A. Office 818-956-1444 Table of Contents

More information

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL 2. Caution Statements and Table of Contents Table of Contents 2. Caution Statements and Table of contents 3. Important Safety Instructions 4. Important Safety

More information

All the functions you need in your hand

All the functions you need in your hand All the functions you need in your hand Rely on H30FLEX for installation and troubleshooting. Robust, light-weight and extremely easy to use. Carry out installation, maintenance and troubleshooting tasks

More information

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING...

English CONTENTS 1. GUIDE OUTLINE THE MENU OSD INSTRUCTION TECHNICAL SPECIFICATION TROUBLE SHOOTING... USER S MANUAL English CONTENTS 1. GUIDE...2 1.1 IMPORTANT SAFETY INSTRUCTIONS...2 1.2 UNPACKING...2 1.3 PRODUCT OVERVIEW& ILLUSTRATION...3 1.4 INSTALLATION OF METER...4 2. OUTLINE...5 3. THE MENU OSD INSTRUCTION...6

More information

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals Tailored to Simplify Installation and Troubleshooting of RF Signals Intuitive Color Display with Simple Pass/ Fail Indicators Reduce Installer Entry Errors and Improves Decision Making Autotests Streamline

More information

JD725A Cable and Antenna Analyzer - Dual Port

JD725A Cable and Antenna Analyzer - Dual Port COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD725A Cable and Antenna Analyzer - Dual Port Key Features Portable and lightweight handheld instrument Built-in wireless frequency bands as well as the most

More information

Digital and analogue image demodulation. All measurements simultaneously. Professional spectrum. Full automatic operation. Autonomy of 4½ h.

Digital and analogue image demodulation. All measurements simultaneously. Professional spectrum. Full automatic operation. Autonomy of 4½ h. Digital and analogue image demodulation All measurements simultaneously Professional spectrum Full automatic operation Autonomy of 4½ h. Weight less than 2 kg. the TV Explorer: setting new standards The

More information

Xpresionn Digital Terrestrial Receiver. User Guide

Xpresionn Digital Terrestrial Receiver. User Guide Xpresionn 2150 Digital Terrestrial Receiver User Guide GENERAL INFORMATION...3 A) SAFETY PRECAUTIONS...3 B) MAIN FEATURES...4 C) CONTENTS OF THE PACKAGING...4 D) REMOTE CONTROL...5 INSTALLATION...6 A)

More information

Agilent CSA Spectrum Analyzer N1996A

Agilent CSA Spectrum Analyzer N1996A Agilent CSA Spectrum Analyzer N1996A Demonstration Guide Introduction This step-by-step demo guide will help you explore the unprecedented value of the Agilent CSA spectrum analyzer for meeting your design,

More information

8dtek DSM Desired. Business Voucher Direct Contact to Sales Manager. TELE-satellite Magazine

8dtek DSM Desired. Business Voucher  Direct Contact to Sales Manager. TELE-satellite Magazine TEST REPORT 该独家报道由技术专家所作 Satellite Signal Analyzer 8dtek DSM Desired includes features normally only found in much higher priced products shows constellation and spectrum handles all DiSEqC variants including

More information

Easy-to-use : setup, frequency maps, recorded data can be saved or downloaded from a USB memory stick.

Easy-to-use : setup, frequency maps, recorded data can be saved or downloaded from a USB memory stick. TV picture : the high quality LCD screen is used to provide TV pictures, SD or HD TV programs, for terrestrial, cable and satellite. Easy-to-use : setup, frequency maps, recorded data can be saved or downloaded

More information

MANUAL ENG DT-1610C. Also contains Menu options and data for built-in modulator Data for broadband amplifier QAM PAL

MANUAL ENG DT-1610C. Also contains Menu options and data for built-in modulator Data for broadband amplifier QAM PAL ENG-1 050815 50026 Also contains Menu options and data for built-in modulator Data for broadband amplifier QAM PAL A versatile and future-proof digital receiver Built-in, thermostat controlled fan. Sound

More information

SYMBOLS USED ON THE RECEIVER... 3 SAFETY INSTRUCTIONS... 4 I.GENERAL INFORMATION...

SYMBOLS USED ON THE RECEIVER... 3 SAFETY INSTRUCTIONS... 4 I.GENERAL INFORMATION... Table of Contents SYMBOLS USED ON THE RECEIVER... 3 SAFETY INSTRUCTIONS... 4 I.GENERAL INFORMATION... 5 1. Preface... 5 2. Main Features... 5 3. General Operation of the Receiver... 6 4. Front Panel...

More information

MyM Pro 3S/6S Installation guide

MyM Pro 3S/6S Installation guide MyM Pro 3S/6S Installation guide CONTENT 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. IP settings 5. Menus and settings web ui 5.1 Overview menu 5.2 Input settings 5.3 Output

More information

PART 1 English 1.0 Usage

PART 1 English 1.0 Usage SAT OUT SAT IN Thank you for choosing this Strong satellite receiver. This receiver is of our latest development and it is designed to be capable of safely install your receiver and to achieve its optimum

More information

HD RANGER+ Evolution? NO. Revolution!

HD RANGER+ Evolution? NO. Revolution! Evolution? NO. Revolution! The SIXTH GENERATION field meter FROM PROMAX ACTUAL SIZE - 7 SCREEN (APPROX. 155 x 93 mm) Revolutionising the market. Again The largest and brightest display HD RANGER+ 7 display

More information

Digital headend system CDH TRIAX - your ultimate connection

Digital headend system CDH TRIAX - your ultimate connection Aerials Dishes Receivers Headends Multi switches Amplifiers Outlets Home accessories Fibre cabinets Enclosures Digital headend system 1 TRIAX - your ultimate connection The headend system adds flexibility

More information

Portable TV Meter (LCD) USER S MANUAL

Portable TV Meter (LCD) USER S MANUAL 1 Portable TV Meter User Manual (LCD) Portable TV Meter (LCD) USER S MANUAL www.kvarta.net 1 / 19 2 Portable TV Meter User Manual (LCD) Contents 1. INTRODUCTION... 3 1.1. About KVARTA... 3 1.2. About DVB...

More information

ST-4000D SIGNAL LEVEL METER

ST-4000D SIGNAL LEVEL METER ST-4000D SIGNAL LEVEL METER Rev 100606 Table of Contents Features / Specifications.... 1 Keypad Illustration....... 2 Keypad Controls.... 2 Getting Started: Powering the Meter...... 3 Quick Use Instructions.....

More information

MANUAL ENG DT-2200 ENGLISH QPSK

MANUAL ENG DT-2200 ENGLISH QPSK ENG-1 011001 01042 ENGLISH 49 64 QPSK 01042-4 ENG-1.p65 49 A versatile digital receiver with a guaranteed future One of the advantages with is the flexible design. The receiver is equipped with a Common

More information

Single & Dual Input HD Digital DVB-T Modulators

Single & Dual Input HD Digital DVB-T Modulators Radio Frequency Range Installation Diagram digi-mod HD-1000DM / HD-2000DM www.resi-linx.com Single & Dual Input HD Digital DVB-T Modulators ANT IN 1 2 3 4 AUX MOD RF IN TV OUTPUTS MOD RF IN (PWR/IR PASS)

More information

LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS

LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS Multimedia Electronics LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS 5 VERSIONS FOR EVERY REQUIREMENT Antenna Measuring Technology By Professionals for Professionals The UPM Range for CATV, and Terrestrial

More information

FLAT DISPLAY TECHNOLOGY

FLAT DISPLAY TECHNOLOGY 15.0 Open Frame Monitor Model Number: LOF1506xx This product is RoHS compliant SPEC No.: SAS-1008002 Version: 0.0 Issue Date: September 6, 2010 1. Introduction: 1.1 About the Product The LOF1506xx 15.0

More information

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals Tailored to Simplify Installation and Troubleshooting of RF Signals Intuitive Color Display with Simple Pass/ Fail Indicators Reduce Installer Entry Errors and Improve Decision Making Autotests Streamline

More information

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas Broadcasting Product Brochure 03.00 R&S EFL240/ R&S EFL340 Portable TV Test Receiver

More information

RANGERNeo + ATSC TV, CABLE, SATELLITE & WIFI ANALYSER HEVC H.265 WIFI ANALYSER EASY OPERATION WIDEBAND LNB A NEW STANDARD IN FIELD STRENGTH METERS

RANGERNeo + ATSC TV, CABLE, SATELLITE & WIFI ANALYSER HEVC H.265 WIFI ANALYSER EASY OPERATION WIDEBAND LNB A NEW STANDARD IN FIELD STRENGTH METERS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com A NEW STANDARD IN FIELD STRENGTH METERS TV, CABLE, SATELLITE & WIFI ANALYSER RANGERNeo

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Tianjin Deviser Electronics Instrument Co., Ltd.

Tianjin Deviser Electronics Instrument Co., Ltd. Operation Manual DS2400T DVB-T2 Signal Analysis Meter Ver:1.10 Tianjin Deviser Electronics Instrument Co., Ltd. Deviser Part No.: 2400T2-DL All rights reserved. Printed in CHINA. Dec. 2012. Warranty The

More information

Refs , , Instruction Manual. Digital processing handheld DVB meter / Analyzer.

Refs , , Instruction Manual. Digital processing handheld DVB meter / Analyzer. Refs. 593301, 593302, 593303. 593304 EN Digital processing handheld DVB meter / Analyzer Instruction Manual www.televes.com Index EN General specifications... 4 Technical specifications... 4 Product Operation...

More information

FRONT VIEW. Find the user's manual on the download area at: QUICK REFERENCE GUIDE. F CONNECTOR Downstream input.

FRONT VIEW. Find the user's manual on the download area at:   QUICK REFERENCE GUIDE. F CONNECTOR Downstream input. FRONT VIEW 1 2 15 3 4 14 13 5 12 6 7 11 10 8 9 1 F CONNECTOR Downstream input 6 Cursor keys 11 Power input 2 F CONNECTOR Upstream input 7 Selection key 12 Speaker 3 LCD display 8 Alphanumeric keypad 13

More information

MANUAL ENG DT-2100 ENGLISH QPSK

MANUAL ENG DT-2100 ENGLISH QPSK ENG-1 010326 00983 ENGLISH 49 64 QPSK 00983-4 ENG-1.p65 49 A versatile digital receiver with a guaranteed future One of the advantages with is the flexible design. The receiver is equipped with a Common

More information

FireTV User's Guide 1

FireTV User's Guide 1 FireTV User's Guide 1 Table of contents 1. Introduction... 3 Features:... 3 Input:... 3 Output:... 3 Technology Summary... 4 DVB Overview... 4 Digital Satellite Equipment Control (DiSEqC) Overview... 5

More information

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx Displays 15.0 Open Frame Monitor Model Number: AND-TFT-150Bxx The AND-TFT-150Bxx 15.0 Open Frame Monitor series are rugged, high performance Industrial LCD Monitors, designed for commercial and industrial

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

NS-3 RF Noise Source Operation Manual

NS-3 RF Noise Source Operation Manual RF Noise Source Operation Manual Version 2.04 June 3, 2016 SPECIFICATIONS Frequency... Maximum output level... Output flatness... (at max output level) Impedance... Displayed level... Repeatability...

More information

Model Three Signal Level Meter. Operation Manual

Model Three Signal Level Meter. Operation Manual Model Three Signal Level Meter Operation Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks Broadcasting Product Brochure 02.00 R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector

More information

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction: 6.4 Chassis Monitor Model Number: LCM0642xx This product is RoHS compliant SPEC No.: SAS-0908003 Version: 0.0 Issue Date: April 16, 2010 1. Introduction: 1.1 About the Product The LCM0642xx 6.4 Chassis

More information

SPECIFICATION. DVB-T/ DVB-C / Worldwide hybrid Switchable NIM Tuner

SPECIFICATION. DVB-T/ DVB-C / Worldwide hybrid Switchable NIM Tuner 1.Feature *. Integrated RF switch, NTSC VIF demodulator, COFDM demodulator *. All-in-one full NIM function with compact size, optimal solution for cost reduction and shortening product development lead-time.

More information

Satellite, Terrestrial, Cable & CCTV Testing Instrument. User s Guide

Satellite, Terrestrial, Cable & CCTV Testing Instrument. User s Guide Satellite, Terrestrial, Cable & CCTV Testing Instrument + User s Guide CONTENTS OVERVIEW... 3 FEATURES... 3 PRODUCT OVERVIEW... 4 PACKAGE CONTENTS... 4 FRONT PANEL KEYS... 5 BACK PANEL... 5 FRONT PANEL

More information

860 DSPi. Multifunction HFC Analyzer. Enhanced Sweep and RSVP Features. DSP Technology Provides Quick, Accurate Measurements

860 DSPi. Multifunction HFC Analyzer. Enhanced Sweep and RSVP Features. DSP Technology Provides Quick, Accurate Measurements 860 DSPi Multifunction HFC Analyzer Enhanced Sweep and RSVP Features DSP Technology Provides Quick, Accurate Measurements Tests DOCSIS Cable Modem Performance and VoIP Quality Analysis Internet Browser

More information