FL-B101D40 Leopard Bargraph Meter 101 Segment, 4 Digit 0.32 LEDs in a 9/64 DIN CASE

Size: px
Start display at page:

Download "FL-B101D40 Leopard Bargraph Meter 101 Segment, 4 Digit 0.32 LEDs in a 9/64 DIN CASE"

Transcription

1 General Features LEOARD FAMILY External transmitters or signal conditioners can be eliminated by direct connection of the sensor output to more than lug-in Input Signal Conditioners that include: AC/DC Current ressure Resistance AC/DC Voltage rocess Temperature Load Cell rototype to ma Optional isolated 6 bit analog output. User or factory scalable to to ma, to ma or to V across any desired digital span from ± one count to the full scale range of 999 to 9999 ( counts). A rogrammable Tricolor (Red-Green-Orange) or mono color (red or green), segment high brightness bargraph. Vertical or optional horizontal format. Red -digit LED display with a range of -999 to 9999 ( counts). Optional green digital display. Front panel LED annunciators provide indication of setpoint status. Two Amp Form C, and two 5 Amp Form A relays available Auto-sensing AC/DC power supply. For voltages between V AC / 95-7 V DC (S) or 8-8 V AC / -7 V DC (S). V DC excitation is available to power external /ma transmitters and 5 or V DC excitation is available for resistance bridge type sensors. rovision to connect an external programming lockout switch. rovision for external DIM switch to reduce the brightest display setting by 5%. Optional NEMA- front cover. Automatic intelligent averaging, smooths noisy signals while providing a fast display response to real level changes. Software Features The bargraph can display, full scale, any desired portion of the digital reading. Bargraph center zero function. Four programmable setpoints with adjustable Hysteresis. Setpoint has delay-onmake and delay-on-break plus a special pump on pump off mode that creates Bargraph Center oint Display Mode Selection.. 6 Bargraph Color rogramming Mode Case Dimensions Component Layout Connector inouts Connectors Controls and Indicators Custom Faceplates and Scales Decimal oint and Brightness Selection a Hysteresis Band between S and S. Relay activation can be selected to occur above (hi) or below (Lo) each setpoint. Digital display blanking. Decimal point setting. Four-level brightness control accessed by the button and adjusted by the button. Index FL-BD Leopard Bargraph Meter Segment, Digit. LEDs in a 9/6 DIN CASE Now featuring New Version. software with one-color Brightness control, this smart Tricolor or Mono-color digital bargraph has four fully programmable set points for monitoring, measurement, and control applications. Input Module Compatibility LEOARD FAMILY: More than 8 different lug-in I-Series Input Signal Conditioners are approved for Texmate s Leopard Family of meters. Some examples are shown on pages - 5. See for an up to date listing. LEOARD Specifications Digital Span Selection for Display Digital Span Selection for Analog Range Output. 6 Functional Diagram General Features I-Series Input Signal Conditioning Modules. -5 Input Module Calibration rocedures Input Module Component Glossary Ordering Information in Descriptions Version. Input Specs:...Depends on Input signal conditioner A/D Converter:... bit single slope Accuracy:...±(.5% of reading + counts) Temp. Coeff.:... ppm/ C (Typical) Warm up time:... minutes Conversion Rate:... conversions per second (Typical) Digital Display:... digit." LED red (std), green (optn) Range 999 to 9999 counts. Bargraph Display:... segment red vertical (std), green or tricolor (optn), horizontal (optn) olarity:...assumed positive. Displays negative Decimal Selection:...Front panel button selectable, X X X X ositive Overrange:..Bargraph and top segments of digital display flash. Negative Overrange:.First segment of bargraph and bottom segments of digital display flash. Relay Output:...Two 5 Amp Form A relays and Two Amp Form C relays. Analog Output:...Isolated 6 bit user scalable ma or V OIC (ma out)...- to 5Ω max loop resistance OIV (volts out)... - V 5 Ω or higher resistance ower Supply:...AC/DC Auto sensing wide range supply S (std) VAC / 95-7 max.w S VAC / -7 max.w Operating Temp.:... to 6 C Storage Temp:... C to 7 C Relative Humidity:...95% (non condensing) Case Dimensions:...9/6 DIN (Bezel 6WxHmm) Depth behind bezel (5.8") 8mm lus (.7 ) 8mm for connectors Weight: oz., oz when packed rogramming Conventions Setpoint Setting & Relay Configuration Mode. 8-9 Software Features Software Logic Tree Specifications Standard Faceplates and Scales Two oint Analog Range Setting & Calibration... 7 Two oint Digital Calibration Mode Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age

2 Controls and Indicators Setpoints indicated by an ON Segment Setpoints indicated by an OFF Segment Seven Segment LED Display Front anel Buttons rogram Button Segment Bargraph LED Annunciators for Setpoints - U Button ROGRAM Button DOWN Button The button is used to move from one program step to the next. When pressed at the same time as the button, it initiates the calibration mode. When pressed at the same time as the button, it initiates the setpoint setting mode. rogramming Conventions To explain software programming procedures, logic diagrams are used to visually assist in following the programming steps. The following symbols are used throughout the logic diagrams to represent the buttons and indicators on the meter: Up Button When in the operational display, pressing the button allows you to view the setting of the saved eak and Valley Values. When setting a displayed parameter during programming, the button is used to increase the value of the displayed parameter. Down Button When in the operational display, pressing the button allows you to change the Brightness Level as well as to view the setting of the setpoints S, S, S & S. When setting a displayed parameter during programming, the button is used to decrease the value of the displayed parameter. Front anel LED Display Annunciator LEDs The annunciator LEDs indicate the alarm status. They are labeled from bottom to top: S, S, S, S. Digital LED Displays The digital LED displays are used to display the meter input signal readings. They also display the programming settings during programming. Setpoint Indication The position of setpoints on the bargraph display are indicated by an ON or OFF segment dependent on the bargraph display being above or below the setpoint. When the and buttons are shown together, the display value can be increased by pressing and releasing the button or decreased by pressing and releasing the button. This symbol represents the OERATIONAL DISLAY. This is the ROGRAM button. This is the U button. This is the DOWN button. When the and buttons are shown with two displays, either display can be selected by pressing and releasing the or buttons. When two displays are shown together with bursts, this indicates that the display is toggling (flashing) between the name of the function and the value. When a button is shown, press and release it to go onto the next step in the direction indicated by the arrow. When an alternative dotted line is shown, this indicates that an alternative logic branch will be followed when a particular option is present. [Span] [] Text or numbers shown between square brackets in a procedure indicate the programming code name of the function or the value displayed on the meter display. When two buttons are shown side by side and enclosed by a dotted line, they must be pressed at the same time then released to go onto the next programming step. [X XXX] [XX XX] [XXX X] [XXXX ] [XXXX] When there are more than two display selections they are shown in brackets below the first display and are also selectable by pressing and releasing the or buttons. If an X appears through a digit, it means that any number displayed in that digit is not relevant to the function being explained. A dotted line enclosing an entire logic diagram indicates that programming branch will appear only when a particular option is present. age Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

3 Software Logic Tree The FL-BD is an intelligent bargraph meter with a hierarchical software structure designed for easy programming and operation, as shown below in the software logic tree. Operational Display Software Version is Displayed on ower-up When power is applied, all segments of the bargraph and digital display light up for seconds. The version number of the installed software is then displayed for seconds, after which, the operational display indicates the input signal. MAIN MENU Select the desired reading for the applied Lo input signal Select the desired reading for the applied hi input signal Bargraph Display Scale hi Range Setting [bhi] Bargraph Display Scale Lo Range Setting [blo] Set the Decimal oint [dp] Display Brightness [br] Dimmest Dim Bright Brightest Goes directly to Zero setting if Analog Output is not installed TWO OINT DIGITAL CALIBRATION MODE See age Sub-menu MODE Calibration Mode Err. Indicates unsuccessful calibration Any new settings are canceled and previous settings are retained DIGITAL SAN SELECTION FOR BARGRAH DISLAY See age 5 DECIMAL OINT AND BRIGHTNESS SELECTION See age 5 [X XXX] [XX XX] [XXX X] [XXXX ] [XXXX] This branch will only appear if the analog output option is installed Calibration Input Calibration Output This branch will only appear if the analog output option is installed eak [EAK] Valley [VALY] Bargraph Center oint Display Selection [cto] Digital Display ON/OFF Selection [dis] EAK & VALLEY VIEW & RESET Reset EAK Reset VALY TWO OINT ANALOG OUTUT RANGE SETTING AND CALIBRATION See age 7 Calibrate Analog Output Low [clo]. + Calibrate Analog Output High [chi]. + Select the Digital Reading at which the Analog Output Hi [chi] will occur Select the Digital Reading at which the Analog Output Lo [clo] will occur Back to Operational Display DIGITAL SAN SELECTION FOR ANALOG RANGE OUTUT See age 6 BARGRAH CENTER OINT DISLAY MODE SELECTION See age 6 DIGITAL DISLAY ON/OFF See age 6 BRIGHTNESS AND SETOINT VIEW MODE Display Brightness [br] Dimmest Dim Bright Brightest Setpoint [S] Setpoint [S] Setpoint [S] Setpoint [S] ump On ump Off When UM is selected ON, and S is set at a value higher than S, the S relay will operate in a special "pump on pump off" Hysteresis mode. S acts as the upper limit and S acts as the lower limit of the Hysteresis Band. For filling applications, rlys should be set to LhLh. S will then activate for inputs less than the S setpoint, and remain ON until the S setpoint is reached. For emptying applications, rlys should be set to hhhh. S will then activate for inputs greater than the S setpoint, and remain ON until the S setpoint is reached. SETOINT SETTING AND RELAY CONFIGURATION MODE See age 8 Set Setpoint [S] Delay-on-Make [dom] NOTE: [dom] [dob] Functions are only available for S Delay-on-Break [dob] Hysteresis [hyst] ump [UM] Setpoint [S] Hysteresis [hyst] Setpoint [S] Hysteresis [hyst] to 9999 seconds to 9999 seconds Relays Activation [rlys] L or h (h) High the relay energizes when the L or h setpoint is exceeded. (L) Low the relay L or h energizes below the setpoint. Bar Color [col] L or h BARGRAH COLOR ROGRAMMING MODE See age 9 NOTE: Will only appear if a tricolor display is installed Tricolor Bargraph The tri-color bargraph is designed like a traffic light, to display either red, orange or green, but only one color at a time. The color to be displayed is selected in two ways. The first step is to select the color to be displayed when the bar is below whichever set point is set to the lowest position. The second step is to select the color to be displayed when the bar is above each specific setpoint, regardless of the order or position to which the set points are set. 5 Second rogram Timeout Except for ZERO and SAN settings in the Two oint Digital Calibration Mode and the Analog Output Range Setting and Calibration Mode (clo and chi), the meter has a 5 second program timeout. If no buttons are pressed for 5 seconds in any of the other programming sequences, the meter will exit the programming mode and return to the operational display. Any program changes that were made prior to pressing the button in the preceding step will not be saved. Setpoint [S] Hysteresis [hyst] However, if two or more setpoints with differently specified colors are positioned at the same set point value, the color specified for the set point with the highest identifying number will be displayed. When setpoints are set to the same value, the S color overrides the S color, the S color overrides the S color, and the S color overrides the S color. Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age

4 Two oint Digital Calibration Mode This mode enables the meter to be calibrated by applying a zero or low input signal, entering the desired reading for that signal, then applying a high input signal, and then entering the desired reading for that signal. The meter then automatically calculates and programs in the requisite scale factor, within the following parameters.. ositive and negative signals may be applied, but the difference between the low and the high signal inputs must be at least counts or Err will be indicated.. ositive and Negative values for the desired reading can be entered, but the scale factor created can not exceed the Digital Display Span capability of the meter which is, counts between 999 to The internal Signal Span is limited to V DC between V DC to + V DC. Any outputs from an Input Signal Conditioning module that exceed these limits will cause the meter to indicate overrange regardless of the Digital Display Span scaled. Note: Many input signal conditioners have provisions for analog calibration and scaling. If the meter is digitally set to read zero with a zero input (shorted input), and to read with a. V input, any pre-calibrated analog signal conditioner, with an output that does not exceed V to + V, will read correctly without any further calibration when it is inserted in the meter. MAIN MENU Operational Display Sub-menu MODE STE A Enter the Calibration Mode ) ress the and buttons at the same time. Display toggles between [CAL] and [off]. ) ress the or button. Display changes from [off] to [on]. ) ress the button. Display toggles between [CAL] and [out]. Note: If at this point, the display skips directly to STE C and toggles between [SAn] and the previous [San] setting, the software is detecting that the optional analog output hardware is NOT installed. STE B Select Two oint Digital Calibration of Input Signal ) ress the or button to select CAL [i] for input signal calibration. ) ress the button. Display toggles between [ZEro] and the previous zero setting. STE C Set the Meter s Low Input Signal Reading on the Digital Display ) Apply a zero or low signal to the meter. (ositive or negative values are allowed). ) Using the and buttons, adjust the meter display to the desired reading for the applied low input signal. ) ress the button. Display toggles between [SAn] and the previous span setting. STE D Set the Meter s High Input Signal Reading on the Digital Display ) Apply a high input signal to the meter. ) Using the and buttons, adjust the digital display to the desired reading for the applied high input signal. ) ress the button. The Digital Calibration rocedure is now complete. If the digital calibration was successfully completed, the menu branches to the Digital Span Selection for Bargraph Display (see page 5), and the display flashes [bhi] and the previous setting. STE A Calibration Mode To Digital Span Selection for Bargraph Display See age 6 STE B Calibration Mode To Two oint Analog Output Range Setting and Calibration See age 7 STE C Zero STE D Span cal out/i branch will only appear if the analog output option is installed, otherwise cal on goes directly to ZEro setting TWO OINT DIGITAL CALIBRATION MODE ERROR Indicates Unsuccessful Calibration If the calibration was unsuccessful, the display indicates [Err], the new calibration settings just entered will not take effect and the previously stored setting will remain. The three most likely causes of an error during calibration are:. The full scale and zero signals were too similar. The full scale signal must be at least counts greater than the zero or low input signal (positive and negative values are allowed).. The scaling requirement exceeded the digital display span capability of the meter (, counts between 999 to 9999).. No input signal present, or incorrect input signal connections. Err. Any new setting canceled and previous settings are retained To Digital Span Selection for Bargraph Display age 5 age Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

5 Digital Span Selection For Bargraph Display The bargraph can be set to display full scale (- bars) any portion of the digital reading from a minimum of counts to a maximum of, counts. This provides higher resolution bargraph indication for those applications where the normal operating input signal range is less than the desired full scale display range of the digital display. For Example: If the full scale range of the meter has been set from -999 to 9999 (-, counts), but the normal operating range of the input signal is between & 6. The bargraph high parameter [bhi] can be set to 6 and the bargraph low parameter [blo] can be set to. This means that although the meter could digitally display a signal from -999 to 9999 (-, counts), the bargraph display only begins to function at a reading of, and reaches full scale indication at a reading of 6. Although the digital display will continue reading up to 9999 before indicating overrange, the bargraph display will indicate its overrange by flashing for readings above 6. Example of Setting the Digital Span of the Bargraph Display to be Different than the Digital Display Range No bargraph display Digital display Bargraph does not light up for Input Signals up to 999 counts % S Bargraph display ends at 6 counts At 5 counts the bargraph display will be at midpoint Bargraph display starts at counts Digital display % S Bargraph lights up for Input Signals above counts STE A Enter the Calibration Sub Menu Mode ) ress the and buttons at the same time. Display toggles between [CAL] and [off]. ) ress the button. Display toggles between [bhi] and the p r e v i o u s setting. STE A From Two oint Digital Calibration Mode See age DIGITAL SAN SELECTION FOR BARGRAH DISLAY STE B Set the Digital Span of the Bargraph Display (See example above) ) Using the and buttons, adjust the display to the desired high parameter reading, e.g. 6 counts. ) ress the button. Display toggles between [blo] and the previous setting. ) Using the and buttons, adjust the display to the desired low parameter reading, e.g. counts. ) ress the button. Display changes from [] to [d]. STE B See Example Above of Bargraph Display Scale Range Example Example Decimal oint and Brightness Selection STE C Set the Decimal oint ) Using the and buttons, adjust the display to the desired decimal point setting. ) ress the button. Display toggles between [br] and the previous brightness setting. STE D Set the Bargraph and Digital Display Brightness ) Using the and buttons, adjust the display to the desired brightness setting ( is the brightest setting). ) ress the button. Display toggles between [Anhi] and the previous [Anhi] setting. Note: If at this point, the display skips directly to STE G and toggles between [Cto] and [off], the software is detecting that the optional analog output hardware is NOT installed. STE C STE D DECIMAL OINT AND BRIGHTNESS SELECTION [X XXX] [XX XX] [XXX X] [XXXX ] [XXXX] To Digital Span Selection for Analog Range Output or Bargraph Center oint Display Mode Selection on age 6 Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age 5

6 Digital Span Selection for Analog Range Output STE E Selecting the [Anhi] Digital Value for Analog High Output ) Using the and buttons, adjust the display to the desired digital value at which the [chi] Calibrated Analog High output will occur. For digital readings outside the digital span selected, the analog output will linearly rise above the value set for chi, up to the maximum analog output capability. However, the analog output will not go lower than the calibrated value set for clo (see below). ) ress the button. Display toggles between [AnLo] and previous [AnLo] setting. STE F Selecting the [AnLo] Digital Value for Analog Low Output ) Using the and buttons, adjust the display to the desired digital value at which the [clo] Calibrated Analog Low output will occur. For Digital readings outside the Digital Span selected, the analog output will not go lower than the calibrated value set for clo. ) ress the button. The display toggles between [cto] and [off]. Note: Any two digital span points from 999 to 9999 can be selected. The digital values for [Anhi] analog high and [AnLo] analog low can be reversed to provide a to ma output. The digital span selected can be as small as two counts, when using the analog output to function as a Control or Alarm Driver. Small digital spans will cause the high resolution 6 bit D to A to increment digitally in stair case steps. See Two oint Analog Output Range Setting and Calibration at the top of the next page. From Decimal oint and Brightness Selection See age 5 DIGITAL SAN SELECTION FOR ANALOG RANGE OUTUT STE E STE F This branch will only appear if the analog output option is installed To Bargraph Center oint Display Mode Selection Below Bargraph Center oint Display Mode Selection Example of Using the Center oint Bargraph Display Mode with a Unipolar Input 5 Center oint Single Bar Lit 5 5 As signal increases Center oint 5 5 Center oint 5 If the meter's full scale range is set to 5 counts, the midpoint would be 5 counts. If a signal of 5 counts is applied only one segment at the 5 count mark will light up. If a signal of counts is applied the segments between the center segment (5 counts) and the count mark light up. If a signal of counts is applied, the segments between the center segment (5 counts) and the count mark will light up. Example of Using the Center oint Bargraph Display Mode with Bipolar Signal Inputs + V Center oint Single Bar Lit V + V As signal increases.8 Center oint V As signal decreases + V Center oint V The meter may also be calibrated to display symmetrical bipolar signals such as ± V or ± V. When the center point display mode is selected, it will then function as a center zero meter. When positive signals are applied, the bar will go up from the center point, and when negative signals are applied, the bar will go down from the center point. - V - V -.8 As signal decreases - V STE G Bargraph Center oint Mode Selection (See example above) ) To select bargraph center point mode, press the or button. Display changes from [off] to [on]. ) ress the button. Display toggles between [dis] and [on] or [off]. STE H Digital Display ON/OFF Selection ) To set the display to [off], press the or button. Display toggles between [dis] and [off]. ) ress the button. The display exits the calibration mode and returns to the operational display. Only the bargraph display is on and the digital display is off. If the digital display is selected to be off, pressing any button to make programming changes or to view setpoints activates the digital display. When the procedure is complete, the digital display will then automatically switch off. The Display/Bargraph settings are now complete. From Digital Span Selection for Analog Range Output Above or Direct From Decimal oint and Brightness Selection age 5 if Analog Output Option is Not resent STE G See Example of Bargraph Center oint Display Mode Selection Above BARGRAH CENTER OINT DISLAY MODE SELECTION STE H Operational Display age 6 Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

7 Two oint Analog Output Range Setting and Calibration Determine if the Analog Output Selection Header is in the to ma (-ma) position or the to VDC position. If necessary, the module may have to be removed and the header position changed (see Component Layout below). Note: Always disconnect power from the meter before removing the analog output module to adjust the ma or Volts output selection header and reinstalling it. When power is reconnected, the meter s software will automatically detect the presence or absence of the analog output module. STE A mm(.") 9/6 DIN cutout spacer 8 places Snug Fitting. mm (.7") Enter the Calibration Mode ) ress the and buttons at the same time. Display toggles between [cal] and [off]. ) ress the or button. Display changes from [off] to [on]. ) ress the button. Display toggles between [cal] and [out] input calibration. Note: If at this point the display skips directly to toggle between Zero and the previous Zero setting, the software is detecting that the optional analog output hardware is NOT installed. STE B STE E STE F Enter the Two oint Analog [out] Output Range Setting and Calibration Mode ) ress the button. Display toggles between [clo] and an internal scale factor. Set or Calibrate [clo] the Low Analog Value of the Analog Output Range ) Connect a multimeter to analog output pins 7 and 8 (see Rear anel inouts on page ). Using the and buttons, adjust the analog output to the desired low value as measured on the multimeter. clo may be adjusted to any value from. ma to 8 ma (ma output selected) or from.6 V to 8 V (volt output selected). However, the output of clo must always be less than the value selected for chi. If a reversed analog output is desired, the values selected to establish the Digital Span can be reversed (see top of page 6). For digital readings outside the Digital Span selected, the analog output will not go any lower than the calibrated value set for clo. However, the analog output will linearly rise above the value set for chi, up to the the maximum analog output capability (see chi below). ) ress the button. Display toggles between [chi] and an internal scale factor. Set or Calibrate [chi] the High Analog Value of the Analog Output Range ) Using the and buttons, adjust the analog output to the desired high value as measured on the multimeter display. chi may be adjusted to any value from 8 ma to ma (ma output) or from 8 V to. V (volt output). However, the value must be higher than the value selected for clo. For digital readings outside the Digital Span selected, the analog output will linearly rise above the value set for chi, up to the maximum analog output capability. ) ress the button. The meter exits the calibration mode and returns to the operational display. Note: The analog output range established by the values selected for clo and chi will occur, automatically scaled, between the two digital values selected for AnHi and AnLo. However, the analog output can linearly rise above the chi value set for digital readings outside the digital span selected. See Digital Span Selection on page 6. Case Dimensions ANEL CUTOUT FRONT VIEW Case will mount in standard DIN cutouts places.5mm(.") 9/6 DIN 7.5mm(.") places 6x mm mm (5.5") Mosaic Fitting 5.mm (5.") mm (.") mm (.") 8mm (5.5") Loose Fitting mm (5.69") These dimensions are increased by mm (.8") when the metal surround case is installed Clear Lockable NEMA X Splash roof Lens Cover /N.(O-N/X6 ) S 6mm (.") mm (.6") typical 5mm (.") 7.7mm (5.") 9/6 DIN cutout spacer For extra strength in portable applications, the 8 DIN spacers should be snipped off and the Mosaic fitting cutout used. anel adaptor plates are available to retrofit most existing panel cutouts..5mm (.8") 9/6 DIN cutout spacer SIDE VIEW Max. panel thickness mm (.7") To open rear cover, use a small flat blade screw driver. ress down lightly to release catch and leaver outwards. TO VIEW anel Adaptor to fit existing 6" Edgewise ointer Meter Cut-Outs /N.(O-A/x6) Adaptor uses wide jaw mounting slide clips./n.(75dmc6b) Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age 7.5mm (5.7") Mosaic Fitting For additional strength, extra Mounting Slide Clips can be ordered and doubled up one behind the other. /N. (75-DMCX6) 6mm (.") Right-angled mm Connector (.9") 7.5mm (.6").mm (5.6") ush-on Connector for FI series IO board 6.5mm (.5") Two bezel Trim Strips are supplied with each anel Adaptor The Metal Surround case uses Metal Screw Mount Clips and has a max. panel thickness mounting of 7mm(.8") mm mm (.") (.") Mosaic Fitting 8.mm (.7") Straight-thru Connector.. STE A Calibration Mode STE B Calibration Mode STE E Calibrate Analog Output + x Lo x STE F Calibrate Analog Output + x Hi x Sub-menu MODE To Digital Span Selection for Bargraph Display See age 5 To Two oint Digital Calibration Mode See age Operational Display The adapter snaps on the 6x mm (."x5.69") case and enables single unit or stack mounting in an existing 6" edgewise pointer meter cut-out. When extra panel mounting tightness is required, order the optional screw mount clip. Zero Span Zero Span S S S S Will only appear if the analog output option is installed TWO OINT ANALOG OUTUT RANGE SETTING AND CALIBRATION Operational Display /N.(OMTLCLI) Various bezel colors are available. Black is standard. Metal Surround Case /N.(O-MTLX6) is pre-installed at the factory and cannot be removed without damage to the case.

8 Setpoint Setting and Relay Configuration Mode The following programming steps are required to enter the setpoint values and configure the relay functions in a meter with four relays using four setpoints. Generally if less than four relays are installed, the setpoints without relays are operational in software for tri-color control or display only purposes. To remove unwanted setpoint indications, set them to 9999 or -999 depending on the relay activation mode selected. STE A STE B Enter the Setpoint Mode ) ress the and buttons at the same time. Display toggles between [S] and the previous S setting. Set Setpoint [S] ) Using the and buttons, adjust the display to the desired S value. ) ress the button. Display toggles between [dom] and the previous [dom] setting. STE A STE B Operational Display SETOINT SETTING AND RELAY CONFIGURATION MODE STE C STE D STE E Set the S Delay-on-Make [dom] Delay Time Setting ) Using the and buttons, adjust the display to the desired [dom] value ( to 9999 seconds). The reading must continuously remain in an alarm condition until this delay time has elapsed before the relay will make contact (energize). ) ress the button. Display toggles between [dob] and the previous [dob] setting. Set the S Delay-on-Break [dob] Delay Time Setting ) Using the and buttons, adjust the display to the desired [dob] value ( to 9999 seconds). The reading must continuously remain in a non-alarm condition until this delay time has elapsed before the relay will break contact (de-energize). ) ress the button. Display toggles between [hyst] and the previous [hyst] setting. Select the Hysteresis [hyst] ) Using the and buttons, select the Hysteresis to be ON or OFF. ) ress the button. Display toggles between UM and (on) or (off). STE C STE D STE E STE F Select ump [UM] (on) or (off) ) Using the and buttons, select the ump to be ON or OFF. When UM is selected ON, and S is set at a value higher than S, the S relay will operate in a special "pump on pump off" mode. S acts as the upper limit and S acts as the lower limit of the Hysteresis Band on the S relay. For filling applications: [rlys] should be set to [LhXX] (see step M). The S relay and S LED Annunciator will then activate for inputs less than the S setpoint, and remain ON until the S setpoint is reached. For emptying applications: [rlys] should be set to [hhxx] (see step M). The S relay and S LED Annunciator will then activate for inputs greater than the S setpoint, and remain ON until the S setpoint is reached. ) ress the button. Display toggles between [S] and the previous S setting. STE G Set Setpoint (S) ) Using the and buttons, adjust the display to the desired S value. ) ress the button. Display toggles between [hyst] and the previous [hyst] setting. STE F No [dom] or [dob] STE G No [dom] or [dob] STE H STE H STE I STE J STE K STE L Select the Hysteresis [hyst] ) Using the and buttons, select the Hysteresis to be ON or OFF. ) ress the button. Display toggles between [S] and the previous [S] setting. Set Setpoint (S) (No [dom] or [dob]) ) Using the and buttons, adjust the display to the desired S value. ) ress the button. Display toggles between [hyst] and the previous [hyst] setting. Select the Hysteresis [hyst] ) Using the and buttons, select the Hysteresis to be ON or OFF. ) ress the button. Display toggles between [S] and the previous [S] setting. Set Setpoint (S) (No [dom] or [dob]) ) Using the and buttons, adjust the display to the desired S value. ) ress the button. Display toggles between [hyst] and the previous [hyst] setting. Select the Hysteresis [hyst] ) Using the and buttons, select the Hysteresis to be ON or OFF. ) ress the button. Display toggles between [rlys] and the previous relay setting. STE I STE J STE K STE L lease Continue On Next age. To Step M of Setpoint Setting and Relay Configuration age 9 age 8 Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

9 Setpoint Setting and Relay Configuration Mode Continued STE M Set Relay Activation mode [rlys] for S (h) High the relay energizes when the setpoint is exceeded. (L) Low the relay energizes below the setpoint. The setpoint is indicated from left to right S, S, S, S. ) Using the and buttons, select (L) or (h) for the first digit, which corresponds to S. ) ress the button. The S Relay Activation digit begins to flash, and its decimal point is lit. STE N Set High (h) or Low (L) for S ) Using the and buttons, select (L) or (h) for the second digit, which corresponds to S. ) ress the button. The S Relay Activation digit begins to flash, and its decimal point is lit. STE O Set High (h) or Low (L) for S ) Using the and buttons, select (L) or (h) for the third digit, which corresponds to S. ) ress the button. The S Relay Activation digit begins to flash, and its decimal point is lit. STE Set High (h) or Low (L) for S ) Using the and buttons, select (L) or (h) for the fourth digit, which corresponds to S. ) ress the button. If a mono-color red or green display is installed then the Setpoint Relay rogramming Mode is now complete and the meter returns to the operational display. If a tricolor bargraph display is installed then the Bargraph Color rogramming Mode will be entered and display toggles between [CoL] and the previous setting. Color selection menu will be displayed. From From Step L of Setpoint Setting and Relay Configuration age 8 STE M L or h STE N L or h STE O L or h STE L or h Operational Display Bargraph Color rogramming Mode To comply with the latest safety requirements, the tri-color bargraph is designed like a traffic light, to display either red, orange or green, but only one color at a time. When the bar reaches a selected color change point, the entire bar will change to the color designated for that zone. This eliminates any ambiguity as to the signal status, especially just after transitioning to a new zone. First (Step Q) is to select the color to be displayed, when the bar is below*, whichever set point is set to the lowest position. Second (Steps R, S, T, and U) is to select the color to be displayed when the bar is above each specific set point, regardless of the order or position to which the set points are set. However, if two or more setpoints with differently specified colors are positioned at the same set point value, the color specified for the set point with the highest identifying number will be displayed. When set points are set to the same value, the S color overrides the S color, the S color overrides the S color, and the S color overrides the S color. STE Q STE R BARGRAH COLOR ROGRAMMING MODE NOTE: Will only appear if a tricolor display is installed STE Q Select Bargraph Color when the bar is BELOW* the Setpoint that is set to the lowest position ) Using the and buttons, select the desired bargraph color [grn], [oran] or [red] ) ress the button. Display toggles between [CS] and the previous color setting. STE S STE R Select Bargraph Color when the bar is ABOVE* S Setpoint ) Using the and buttons, select the desired bargraph color [grn], [oran] or [red] ) ress the button. Display toggles between [CS] and the previous color setting. STE T STE S STE T Select Bargraph Color when the bar is ABOVE* S Setpoint ) Using the and buttons, select the desired bargraph color [grn], [oran] or [red] ) ress the button. Display toggles between [CS] and the previous color setting. Select Bargraph Color when the bar is ABOVE* S Setpoint ) Using the and buttons, select the desired bargraph color [grn], [oran] or [red] ) ress the button. Display toggles between [CS] and the previous color setting. STE U STE U Select Bargraph Color when the bar is ABOVE* S Setpoint ) Using the and buttons, select the desired bargraph color [grn], [oran] or [red] ) ress the button. The meter exits the setpoint mode and returns to the operational display. Operational Display The Bargraph Color programming mode is now complete. S *Note: For horizontal display formats BELOW* should be read as, to the left and ABOVE* should be read as, to the right. Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age 9

10 Functional Diagram NO COM & NC NO NO COM & NC NO Analog + Analog rogram Lock Common Dim AC Neutral, DC AC Line, + DC AC/DC ower Input I-Series Input Signal Conditioning Module Input and output pins vary for different modules. lease see the specific module data sheet for details..5 V Bandgap Reference MOV's MOV's GND Connector inouts A A 5A A Isolated 6 Bit Sigma Delta D to A ma Select Header V +5 V DC NTC Socket for Input Signal Conditioning Module 6 8 Input Hi M Input Lo M Multiplexer and +5VDC.. Buffer -5VDC Amplifier +VDC Analog Common Bit Single Ref Hi Slope A to D System Ground + 5 V MUXO V Return Micro rocessor GND + 5 V S + 5 V S + 5 V S + 5 V S GND EMI Filter Isolated Switching Supply FL-BD Functional Diagram This meter uses plug-in type screw terminal connectors for all input and output connections. The power supply connections (pins and ) have a unique plug and socket outline to prevent cross connection. The main board uses standard rightangled connectors. Replacement -, -, and -pin plug connectors are available (see Accessories on page ).! +5 V DC +5 V DC -5 V DC + V DC WARNING: AC and DC input signals and power supply voltages can be hazardous. Do Not connect live wires to screw terminal plugs, and do not insert, remove or handle screw terminal plugs with live wires connected. in Descriptions Input Signal ins to 6 ins to 6 are reserved for the input signal conditioner. See the data sheet for the selected input signal conditioner. ins 8 to 5 Relay Output ins in 8 S NO. Normally Open 5 Amp Form A. in 9 S/ COM. Common for S and S. in S NC. Normally Closed Amp Form C. in S NO. Normally Open Amp Form C. in S NO. Normally Open 5 Amp Form A. in S/ COM. Common for S and S. in S NC. Normally Closed Amp Form C. in 5 S NO. Normally Open Amp Form C. ins 7 to Rear anel Switches ISO GND GND ISO GND + 5 V GND + 5 V GND Input Signal Conditioning Moduls -6 in 8 in 9 in in Display Driver S NO S/ COM NO S COM & S NC S NO NC NO S S NO S/ COM NO S COM & % S NC S NO NC NO S S Relay Activation LEDs Bargraph Segments rogramming Buttons Digital Display LOCK DIM COMM Analog Output Analog Output + AC AC Neutral Line or DC + DC Note: The sequence of setpoint outputs on meters shipped prior to was ---. The sequence is now ---, enabling delay on make (dom) and delay on break (dob) to be used with both Form C relays. ANALOG OUTUT ( ). ma ( to ma/ to ma) or V ( to V) output is header selectable. rogramming LOCK. By connecting the LOCK pin to the COMMON pin, the meter's programmed parameters can be viewed but not changed. COMMON. To activate the LOCK or DIM functions from the rear of the meter, the respective pins have to be connected to the COMMON pin. This pin is connected to the internal power supply ground. DIM. By connecting the display dim (DIM) pin to the COMMON pin, the display brightness setting is halved. ins and AC/DC ower Input Auto-sensing AC/DC power supply. For voltages between V AC / 95-7 V DC (S) or 8-8 V AC / -7 V DC (S). in 7 ANALOG OUTUT (+). ma ( to ma/ to ma) or V ( to V) output is header selectable. in in AC Neutral / DC. Neutral power supply line. AC line / +DC. Live power supply line. age Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

11 + + Component Layout Typical Input Signal Conditioner Relay Activation LEDs GAIN HEADER DC VOLTS CUSTOM V V V No Exc V Exc 9 % Bargraph Segments 9 S % 9 Analog output board placed on edge here Increase SAN Decrease S S S S High Voltage Main Board Typical Input Signal Conditioner Offset HIGH VOLTS MODULE High Voltage Transformer is Colored Grey ins Connect Main Board to Driver Board Display Driver Board S Standard Display Board (Front) Order Code VRR Relay Activation LEDs rogramming Buttons Digital Display rogramming Buttons C F Dual Scale Display Board (Front) Order Code DSRR DC VOLTS V Exc No Exc CUSTOM V V V GAIN HEADER Increase SAN Decrease Offset to ma ( to ma) Selection osition Analog Output Selection Header to V DC Selection osition S S Optional Analog Output Module S S Analog Analog output output board board placed placed on edge on here edge here LOW VOLTS MODULE Low Voltage Transformer is Colored Black Horizontal Bargraph Order Code HRR (Standard) S Low Voltage Main Board Connectors WARNING AC and DC input signals and power! supply voltages can be hazardous. Do Not connect live wires to terminal blocks, and do not insert, remove or handle terminal blocks with live wires connected. Standard plug-in screw terminal blocks provided by Texmate: Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age

12 I-Series Input Signal Conditioning Modules Many additional input modules are available and others are constantly being developed. Check with your local distributor or for updated information. re-calibrated I-Series input modules, that have span or zero potentiometers, can be interchanged between any I-Series compatible meter, without recalibration, because all of the analog scaling and reference circuitry is self-contained within the module. Where appropriate, all the standard ranges shown are designed to be header selectable by the user, and Texmate's unique SAN ADJUST Header facilitates scaling to almost any required engineering unit. See Input Module Component Glossary and Calibration on pages and. Also see Two oint Digital Calibration and Digital Calibration on page. Unless otherwise specified Texmate will ship all modules pre-calibrated with factory preselected ranges and/or scalings as shown in BOLD type. Other pre-calibrated standard ranges or custom ranges may be ordered. Factory installed custom scaling and other custom options are also available (see Ordering Information, Special Options on last page). Symbols Indicate Module Compatibility Within Meter Families TIGER Family LEOARD Family TIGER Family LEOARD Family TIGER Family LEOARD Family! WARNING: AC and DC input signals and power supply voltages can be hazardous. Do Not insert, remove or handle modules with live wires connected to any terminal plugs. LYNX Family LYNX Family LYNX Family ALL MODELS SOME MODELS MODEL SECIFIC IA IA6 IA: IA7 IA IA8 IA IA5 IA9 IA age Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

13 Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7) age I-Series Input Signal Conditioning Modules IA IA ID ID ID ID ID9 ID5 ID7 IF: IGYZ I: I:

14 Texmate, Inc. Tel. (76) age Apr--9 FL-BD DS (FL7) I-Series Input Signal Conditioning Modules I: Ω I7: IT IRΩ Ω Ω IRΩ Ω Ω IRΩ IR5Ω IS IS IS IS5 IS6

15 I-Series Input Signal Conditioning Modules IS7: IT:Ω IT:Ω IT5:Ω IT:Ω Ω Ω ± IT6: IT8: ± ± ± ± IT7: IT9: ± ± ± ± Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age 5

16 Input Module Component Glossary HI V Exc LO Input and Output ins On most modules in is the Signal High input and in is the Signal Low input. Typically in is used for Excitation Voltage output. OFF ON V EXC ON OFF V DC Output Header On some modules this header enables a V DC 5mA (max) Excitation/Auxiliary output to be connected to in. INUT RANGE Header Custom V V V Range values are marked on the CB. Typically two to four positions are provided, which are selected with either a single or multiple jumper clip. When provided, a custom range position is only functional when the option has been factory installed. SAN otentiometer (ot) To the Left Rear ZERO Turn Clockwise to Increase Reading ZERO otentiometer (ot) If provided, the ZERO pot is always to the left of the SAN pot (as viewed from the rear of the meter). Typically it enables the input signal to be offset ±5% of full scale (- to + counts). To the Right Rear SAN Turn Clockwise to Increase Reading If provided, the 5 turn SAN pot is always on the right side (as viewed from the rear of the meter). Typical adjustment is % of the input signal range. Counts + + Counts 5 Turn otentiometer < Increase Span Decrease > 5 5 < Increase Span Decrease > SAN ADJUST Header This unique five-position header expands the adjustment range of the SAN pot into five equal % steps, across % of the input Signal Span. Any input Signal Span can then be precisely scaled down to provide any required Digital Display span from 999 counts to (one count). + Offset + ZERO OFFSET RANGE Header When provided, this three position header increases the ZERO pot s capability to offset the input signal, to ±5% of the digital display span. For example a Negative offset enables a to 5V input to display to full scale. The user can select negative offset, positive offset, or no offset (ZERO pot disabled for two step non-interactive span and offset calibration). SAN Adjust Header position 5 SAN ot % % % % % % Signal Span % % % 6% 8% % Equivalent Circuit Input LO 5 < Decrease Span Increase > Acts like 75 Turn Mega ohm otentiometer Input HI NEGATIVE OFFSET Decreases Digital Reading ZERO ot% % of Offset Offset Range 5 Counts Equivalent Circuit 5 Turn otentiometer Zero Offset Range Header + No Offset Zero ot Disabled OSITIVE OFFSET Increases Digital Reading + % of Offset + 5 Counts 5 Turn otentiometer + LO HI HI LO Range SAN RANGE Header When this header is provided it works in conjunction with the SAN ADJUST Header by splitting its adjustment range into a Hi and a Lo range. This has the effect of dividing the adjustment range of the SAN pot into ten equal % steps across % of the input Signal Span. < Increase Zero Decrease > 5 5 < Increase Zero Decrease > ZERO ADJUST Header When this header is provided, it works in conjunction with the ZERO OFFSET RANGE Header, and expands the ZERO pot s offset capability into five equal negative steps or five equal positive steps. This enables virtually any degree of input signal offset required to display any desired engineering unit of measure. SAN Adjust Header position Span Adjust Header 5 Span Range Header < Decrease Span Increase > < Decrease Span Increase > LO RANGE HI RANGE 5 5 SAN ot % % % % % % Signal Span % % % % % 5% Span Adjust Header 5 % % % % % 6% 7% 8% 9% % Equivalent Circuit Acts like a 5 Turn otentiometer Input LO Low Range High Range HI LO Input HI Zero Offset Range Header NEGATIVE OFFSET OSITIVE OFFSET ZERO Adjust < Increase Zero Decrease > No Offset < Decrease Zero Increase > Header position 5 Zero ot 5 Disabled ZERO ot % % % % % % Offset Range or more counts Equivalent Circuit 75 Turn otentiometer +% +% +% +% +% + or more counts + 75 Turn otentiometer age 6 Texmate, Inc. Tel. (76) Apr--9 FL-BD DS (FL7)

17 Input Module Calibration rocedures In addition to the analog calibration capabilities that enable many modules to be interchanged between different meters without loss of accuracy the Leopard Family of meters have enhanced Digital Calibration functions. Basic standard range calibration of direct reading modules that utilize either Auto Zero or a ZERO pot, an INUT RANGE Header and or a SAN pot. If the module has an INUT RANGE Header, reposition the jumper clip to select the desired input signal range.. Apply a zero input or short the input pins. The display will auto zero, or if the module has a ZERO pot, it should be adjusted until the display reads zero. Apply a known input signal that is at least % of the full scale input range and adjust the SAN pot until the display reads the exact input value. For negative inputs, Leopard Family Meters will display negative overrange at 5% of full scale range. Decimal oints. The selection or positioning of decimal points has no effect on the calibration of the modules Wide range scaling, in engineering units not requiring offsets, with modules that utilize auto-zero or a ZERO pot, a SAN RANGE Header and or a SAN ADJUST Header. Texmate s unique SAN ADJUST and SAN RANGE Headers provide the circuit equivalent of an ultra-precision one megohm 75 or 5 turn potentiometer that can infinitely scale down any Input Signal SAN to provide any full scale Digital Display Span from 999 (counts) to (one count). If the module has an INUT RANGE Header, and the required full scale Digital Display Span (counts) is to be larger than the directly measured value of the input Signal Span, then the next lower range on the INUT RANGE Header should be selected. The resulting over range Signal Span is then scaled down, by selecting the position of the SAN RANGE Header and or the SAN ADJUST Header, which will reduce the input Signal Span to a percentage, that the required Digital Display Span can be reached by calibration with the SAN pot. Example A: to V to read to 8 gallons. Signal Span = V, Digital Display Span = 8 counts Select the V INUT RANGE Header position. This will provide a digital display of 8 counts with an input of only.8 V which is (.8 )=8% of the examples V Signal Span. To scale down the Signal Span to 8% select the % Signal Span position on the SAN ADJUST Header (position ) or if the module has a SAN RANGE Header, select (LO Range) and % Signal Span position on the SAN ADJUST Header (position ). Apply a zero input or short the input pins. The display will auto zero, or if the module has a ZERO pot, it should be adjusted until the display reads zero. Apply V and adjust the SAN pot until the display reads 8. Large offset scaling and calibration of process signal inputs with modules that utilize ZERO ADJUST Headers and or ZERO OFFSET RANGE Headers. Texmate s unique ZERO OFFSET RANGE Header enables the use of a simple two step scaling and calibration procedure for those process signals that require large offsets. This eliminates the back and forth interaction, between zero and span settings, that is often required to calibrate less finely engineered products. The first step is to set the ZERO OFFSET RANGE Header to the center position (No Offset) and scale down the Input Signal Span to a percentage that will enable calibration with the SAN pot to reach the required Digital Display Span. The second step is to set the ZERO ADJUST and or ZERO OFFSET RANGE Header to provide a positive or negative offset of sufficient counts that calibration with the ZERO pot will offset the Digital Display Span to produce the required digital reading. Example B: to 5 V to read to 5 C. Signal Span = V, Digital Display Span = 6 counts If the module has an INUT RANGE Header the V position should be selected. This will provide a digital display of 6 counts for an input of.6 V which is (.6 ) = % of the examples V signal span. To scale down the Signal Span to % select the % Signal Span position on the SAN ADJUST Header (position ). If the module is a rocess Input -5 V DC type, select the (Hi Range) position on the SAN RANGE Header and the % Signal Span position on the SAN ADJUST Header (position 5, max increase). This will provide a digital display of 6 counts for an input of V which is % of the examples V Signal Span. Set the ZERO OFFSET RANGE Header to the center position (no offset). Apply V and adjust the SAN pot until the display reads. A V input would then read 6 counts. Set the ZERO OFFSET RANGE Header to the negative offset position. If the module has a ZERO ADJUST Header select the position that will provide a negative offset of 5 counts. Apply V and adjust the ZERO pot until the display reads. Apply 5 V and check that the display reads 5. Example C: to ma to read. to +.% Signal Span = 6 ma, Digital Display Span = counts. The full scale Signal Span of the rocess Input - ma modules is to ma for a full scale Digital Display Span of to counts. This will provide a digital display of counts with an input of only ma which is ( 6)=6.5% of the examples 6 ma signal span. To scale down the Signal Span to 6.5% select the (Hi Range) osition on the Span Range Header and the 7% Signal Span position on the SAN ADJUST Header (position ). Set the ZERO OFFSET RANGE Header to the center position (no offset). Apply ma and adjust the SAN pot until the display reads 5. A 6 ma input would then read counts. Set the ZERO OFFSET RANGE Header to the positive offset position. If the module has a ZERO ADJUST Header select the position that will provide a negative offset of 5 counts. Apply ma and adjust the ZERO pot until the display reads. Apply ma and check that the display reads. Apr--9 FL-BD DS (FL7) Texmate, Inc. Tel. (76) age 7

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

6-digit, 0.56 (14.2 mm) Alphanumeric Display. 1/8 DIN Case 3-button Front Panel Operation. Intuitive Scrolling Text Configuration Menus

6-digit, 0.56 (14.2 mm) Alphanumeric Display. 1/8 DIN Case 3-button Front Panel Operation. Intuitive Scrolling Text Configuration Menus TIGER FAMILY Introduction The LDT-200 Series are accurate, high performance, programmable dual channel controllers that deliver precise measurement and control for applications using LDT (Linear ariable

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

16-BIT LOAD CELL/DUAL STATUS INPUT

16-BIT LOAD CELL/DUAL STATUS INPUT 16-BIT LOAD CELL/DUAL STATUS INPUT On-board Excitation. +5VDC, (120mA). State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. Optional Excitation

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

Model IQ4-PC User Manual Revision Date:

Model IQ4-PC User Manual Revision Date: Basic Specifications Supply Volts 230V 50/60Hz ±15% 115V 50/60Hz ±15% 24V DC (isolated) ±15% Power Consumption Max. 3VA (IQ4-PC-R0) Max. 6VA (IQ4-PC-R2-PSI24-RT) Operating Temperature -5 ~ +60 C Operating

More information

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC. Fits the Leopard Family FREQ./RM INUT MODULE WITH 24 V EXC. Low-pass Filter., 2 khz,. Switching Comparator. revents false triggering. Input Connector. Freq. Input. 24 V Excitation. Sensor. Mag, Namur,

More information

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN STANDARD FEATURES ±1,999-count display span ±200 mv to ±200 Vdc ranges True-differential input with 80 db CMR 3-wire ratio

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays Operation Manual TX20 1/8 DIN Microcomputer Based /ORP Controller with relays 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

FRQM-2 Frequency Counter & RF Multimeter

FRQM-2 Frequency Counter & RF Multimeter FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features Description Page 1 of 13 The ED3 is an LCD readout that serves as a position indicator or tachometer. The ED3 can display: Speed or position of a quadrature output incremental encoder Absolute position

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

TABLE OF CONTENTS. Instructions:

TABLE OF CONTENTS. Instructions: TABLE OF CONTENTS Instructions: 1 Overview 1 2 Main technical parameters 1 3 Display and keyboard 2 3.1 Display Window 2 3.2 Indicator 4 4. Operation 4 4.1 Power 4 4.2 Zero 4 Modified 4 4.3 Modified 4

More information

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

ProVu PD6000 Process Meter

ProVu PD6000 Process Meter Congratulations on your purchase of the ProVu PD6000 process meter! This quick start guide will briefly describe some of the common setup procedures for this meter. This guide includes: Basic Wiring for

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,

More information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE

More information

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Contents Page 1.0 Overview... 3 2.0 Installation.. 4 2.1 Electrical connections... 4 2.2 Cable selection... 4 2.3 Electrical

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Model 5240 Digital to Analog Key Converter Data Pack

Model 5240 Digital to Analog Key Converter Data Pack Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting 4-0mA Loop Meter with Programmable Backlighting ORDERING INFORMATION Standard Instrument (panel meter, fixing kit, data sheet) DPM 94-FPSI FEATURES 9mm (0.7 ) digit height Dual colour backlight with programmable

More information

Troubleshooting CS800/LC900 Bikes

Troubleshooting CS800/LC900 Bikes Troubleshooting CS800/LC900 Bikes CS800/900LC Bike Troubleshooting Entering the Maintenance Mode 15 Touch Screen: The Maintenance Mode is designed to help the tech determine certain faults in the upper

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL UM-TS02 -E026 PROGRAMMABLE CONTROLLER PROSEC T2-series ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage

More information

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No. Sensor module Ref.No.: SM 1608 V03 Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information could

More information

CARLO GAVAZZI Automation Components

CARLO GAVAZZI Automation Components CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

Signet Chlorine Transmitter

Signet Chlorine Transmitter Signet 8630-3 Chlorine Transmitter English 3-8630.090-3 Rev. D 08/10 English Caution! Remove power to unit before wiring input or output connections. Follow instructions carefully to avoid personal injury

More information

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting and advanced relay sequencing. The contains

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

SIGNET 5500 Flow Monitor ENGLISH

SIGNET 5500 Flow Monitor ENGLISH ENGLISH 3.0901 H (6/01) English CAUTION! Remove power to unit before wiring input and connections. Follow instructions carefully to avoid personal injury. Contents 1. Power Connections 2. Compatible Sensor

More information

Function Manual SIMATIC HMI TP900. Operator Panel.

Function Manual SIMATIC HMI TP900. Operator Panel. Function Manual SIMATIC HMI TP900 Operator Panel Edition 10/2016 www.siemens.com Introduction 1 Safety notes 2 Medium-voltage converters SIMATIC Description 3 Screens 4 Installing software 5 Function

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL OTM-4000 FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000331 REV B www.olsontech.com

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1. USER S GUIDE PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting

More information

Instruction Manual Model BlockUpconverter

Instruction Manual Model BlockUpconverter Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

SAUTER flexotron RDT405 Manual

SAUTER flexotron RDT405 Manual SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties

More information

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR USERS MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000412 Rev. B www.olsontech.com

More information

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009 Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v. 2.1 06 August 2009 I have had several requests to provide a fixed audio output from the K2. After looking at the circuits that

More information

ZIRCONIA OXYGEN ANALYZER CONVERTER

ZIRCONIA OXYGEN ANALYZER CONVERTER Service Manual ZIRCONIA OXYGEN ANALYZER CONVERTER TYPE: ZKM INZ-TN5A0845b-E Contents 1. GENERAL...1 1.1 ZKM1 Internal constitution...1 1.2 ZKM2 Internal constitution...1 1.3 Description on display/setting

More information

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER LUNATEC 35 +48 35 +48 30 40 30 40 0 25 45 25 45 3 192 1 1 6 176.4 20 50 20 50 9 96 12 PEAK 88.2 55 55 RESET 48 10 60 2 10 60 2 21 44.1

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number Features Resolution = 0.004% of nominal range Two, 4, 8, or 32 single-ended inputs per module Out-of-range indication Factory calibrated; no user adjustment necessary SNAP I/O analog input modules are

More information

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416 COMPANY MX 9000 Process Monitor Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:MXMAN082416 1 Table of Contents Unpacking...3 Quick Guide...3 Connect to Sensor...3

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

Omega.com TM. DPS3100 & DPS3200 series Programmable Scanners

Omega.com TM.     DPS3100 & DPS3200 series Programmable Scanners Omega.com TM http://www.omega.com e-mail: info@omega.com DPS3100 & DPS3200 series Programmable Scanners TABLE OF CONTENTS SPECIFICATIONS... 3 DESCRIPTION... 4 DISPLAYING PARAMETERS... 5 Table 1. How to

More information

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller OUTPUT OPTION RELAY 3,4 OPEN COLL 3,4 TEMP 1 SGNL 1 TEMP 2 SGNL 2 - OPEN COLL 4 Æ L ENGLISH 3-8860.090 A-7/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions

More information

DPM OWNERS MANUAL Website: Phone: (800)

DPM OWNERS MANUAL Website:   Phone: (800) DPM OWNERS MANUAL Website: www.flw.com Phone: (800) 576-6308 ORDERING GUIDE L... Meter with screw terminal connectors. Display Color...DPM with green LED 2...DPM with red LED 3...Extended DPM/green LED

More information

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards)

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards) DLM471S-5.1 (Mounted in RMS400 Rack Mount & Power Supply) MULTICHANNEL AUDIO LEVEL MASTER (One of 4 Typical Cards) OPERATION MANUAL IB6432-02B TABLE OF CONTENTS PAGE 1.0 GENERAL DESCRIPTION 2 2.0 INSTALLATION

More information

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

843-R 843-R LASER POWER METER USER MANUAL.  NEWPORT CORPORATION 843-R 843-R LASER POWER METER USER MANUAL NEWPORT CORPORATION www.newport.com Table of Contents Chapter 1.Introduction: How to Use This Manual. 3 Chapter 2.Quick Reference... 4 2.1 Getting Started... 4

More information

Instruction Manual Model # Block Upconverter

Instruction Manual Model # Block Upconverter Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

1900/25 Vibration Monitor

1900/25 Vibration Monitor 1900/25 Vibration Monitor BENTLY NEVADA MADE IN USA VIBRATION MONITOR OK ALERT DANGER BYPASS DISPLAY MOD E RESET NORMAL ALERT ALERT ADJUST LEVEL DANGER DANGER LEVEL ADJUST BUFFER ED TRANSDUCER 1 IN/SEC

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

Standard signal metering in wall-mounting case

Standard signal metering in wall-mounting case User manual AKV-2VR4C Standard signal metering in wall-mounting case Technical features: Digit height: 20 mm Colour: red Range of display: -999 9999 Wall-mounting case: black, made of ABS-plastic Protection

More information

Model 1476-C SuperQuad HR

Model 1476-C SuperQuad HR Model 1476-C SuperQuad HR Installation and Operating Instructions Table of Contents Page Table of Content... 2 System Description... 3 Features... 3 Installation... 4 Internal Setups... 4 Connections...

More information

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7 TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7 FRONT PANEL OPERATIONS...8 PROGRAMMING FLOW CHART...8 DEFINITIONS OF MENU

More information

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.

More information

2002 Martin Professional A/S, Denmark.

2002 Martin Professional A/S, Denmark. Freekie user manual 2002 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

PB-507. Advanced Analog & Digital Electronic Design Workstation Instruction Manual. Revision: 2/2014

PB-507. Advanced Analog & Digital Electronic Design Workstation Instruction Manual. Revision: 2/2014 PB-507 Advanced Analog & Digital Electronic Design Workstation Instruction Manual Revision: 2/2014 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1 1

More information

TimeView Display. Operating Manual

TimeView Display. Operating Manual TimeView Display Operating Manual 9520-647 Airborne Serial Time Display CHAPTER ONE Introduction/Product Overview 4 Operating Manual Summary 5 Purpose of Equipment 5 Preparation for Shipment 6 Typographical

More information

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple

More information

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised SECU-16 Introduction The SECU-16 module allows 8 inputs and 8 low-current relay outputs to be added to an ADICON control system. The inputs may be supervised (switch closure), analog, or 4-20mA. Specifications

More information

FIELD MOUNTED RATE TOTALISER MODEL 202D

FIELD MOUNTED RATE TOTALISER MODEL 202D FIELD MOUNTED RATE TOTALISER MODEL 202D 16 June 2003 Introduction 1 1. INTRODUCTION The Model 202Di Rate Totaliser is a microprocessor based instrument which accepts a frequency or pulse input from

More information

Platinum Tools Inc. All rights reserved. 5/12 Voice, Data, Video + Length GENERAL SPECIFICATIONS WARNINGS

Platinum Tools Inc. All rights reserved. 5/12 Voice, Data, Video + Length GENERAL SPECIFICATIONS WARNINGS Voice, Data, Video + Length Instruction Sheet: P/N T9 GENERAL SPECIFICATIONS The Platinum Tools, VDV MapMaster.0 is a portable voice-data-video cable tester with length measurement. It tests and troubleshoots

More information

INPUT OUTPUT GAIN DELAY. Hue Candela Strobe Controller. Hue Candela s STROBE CONTROLLER. Front Panel Actual Size 7 ¼ By 4 ¾ POWER. msec SEC 10 1.

INPUT OUTPUT GAIN DELAY. Hue Candela Strobe Controller. Hue Candela s STROBE CONTROLLER. Front Panel Actual Size 7 ¼ By 4 ¾ POWER. msec SEC 10 1. Hue Candela s STROBE CONTROLLER INPUT OUTPUT ON TIME POWER NO B C A GAIN X LOCK Y OUT Z Hue Candela Strobe Controller 4 5 6 7..... 8. 3. 9. 2 10.. 1 11. STEP m.. 0 10 1. 10 10 1.0 10 zero DELAY. 03. 02.

More information

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS and trouble-shooting guide LECTROSONICS, INC. Rio Rancho, NM INTRODUCTION The DP1 Dynamic Processor Module provides complete dynamic control of signals

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly. Table of Contents Introduction...3 Safety Information...4-6 Before Beginning Installation...7 Installation Guide...8 Wiring Camera & Monitor...9-10 Replacement Installation Diagram...11 Clip-On Installation

More information