Instruction Manual NivuLog 2 Ex / NivuLog 4 / NivuLog PCM Ex

Size: px
Start display at page:

Download "Instruction Manual NivuLog 2 Ex / NivuLog 4 / NivuLog PCM Ex"

Transcription

1 Instruction Manual for GPRS Data Loggers (Original Instruction Manual German) NIVUS GmbH Im Taele Eppingen; Germany Phone +49 (0) Fax +49 (0) info@nivus.com NivuLog Rev. 02 as of Page 1 / 12

2 Internet: 1 General Important Information Data Loggers And Accessories Initial Setup SIM Card Installation Configuration Of SIM Parameters Test Device Communication Enclosure And Installation Battery Charger NLM0LAD User Interface Device Classes Product Family NivuLog 2 Ex / NivuLog Settings Optimum Antenna Position Certificat NivuLog Rev. 02 as of Page 2 / 12

3 1 General 1.1 Important Information New instruments shall be put into operation in the office and installed on site subsequently. Before using the instrument read the user guide carefully. To clean the enclosure use only mild cleansing agents. The instrument shall be used according to the specifications and regional regulations only. To avoid malfunction or damage of the instrument please only use original parts. Only the manufacturer is allowed to undertake reparations and adaptations Installation, electrical connection, initial setup and maintenance shall be performed only by qualified personnel authorised by the manufacturer. Keep the instrument away from direct sunlight. Observe Ex-restrictions and operational conditions! Do not disassemble the data logger in Ex zones! Operate the data logger on site in conjunction with the protective cover! To avoid electrostatic charge do not rub the protective cover! The rechargeable battery pack as well as the enclosure containing the electronic evaluation components shall be separated by unlocking the snap locks only. Never dismantle the parts in any other way. The enclosure is allowed to be opened out of Ex areas by the manufacturer exclusively for maintenance purposes Rechargeable batteries shall only be replaced in Ex areas. Use the accompanying original battery charger out of Ex areas only Connect the enclosure containing the electronic evaluation components in Ex areas only to a dedicated intrinsically safe rechargeable battery pack. Do not use any other power sources. Never use connection CON 4 (USB connection) in Ex areas. Do not replace the SIM module in CON 6 (SIM card slot) within Ex areas. Connect the original antenna (with or without original 5m extension cable) to connection CON 1 only. NivuLog Rev. 02 as of Page 3 / 12

4 1.2 Data Loggers And Accessories Ordering options NLM0AP424D rechargeable battery pack for NivuLog 4 NLM0AP424DA rechargeable battery pack for NivuLog 2 Ex and NivuLog PCM Ex NLM0LAD424 battery charger for both battery packs NLM5WART01 maintenance kit for gaskets and connections Other alternative antenna types (quad band, omnidirectional etc.) terminal box (for wiring on site) connection cable for measurement interface Hint Antenna and extension cable are consumables NivuLog Rev. 02 as of Page 4 / 12

5 2 Initial Setup 2.1 SIM Card Installation Remove antenna and sensor cable. Uncase the instrument. Remove protective cover as depicted. Press any key briefly (approx. 1 sec.) to prepare the data logger for battery removal. LED goes on during key action Remove the battery as depicted. Press both push buttons while removing. Install the SIM card. Push-Push-System! Observe proper locking! The plugging direction can be seen on the enclosure. Connect the USB cable if required in order to configure the SIM parameters using the DeviceConfig PC software. See following chapters for additional information Use a GPRS enabled SIM card! Observe the cycles (ideally 1kB or less)! See Maintenance Kit manual for gasket and connection maintenance and observe the according measures described therein. Regarding gasket maintenance etc. please observe the measures described in Maintenance Kit. 2.2 Configuration Of SIM Parameters Install DeviceConfig if required Administrative rights required for driver installation! The driver must be re-installed for each new device! Each connected device will be detected by the software automatically. NivuLog Rev. 02 as of Page 5 / 12

6 Enter the GPRS register and configure the SIM parameters. SIM tariff... SIM defaults Overrule... override defaults Service Provider... SIM card provider PIN... PIN code (1234 if deactivated) SIM Lock... locks certain GSM networks MCC... Mobile Country Code MNC... Mobile Network Code Press Save and terminate the USB connections. 2.3 Test Device Communication Create a measurement place in Device 2 Web and assign the NivuLog unit accordingly. Observe proper channel settings already at this stage! Start the ALOHA mode in order to transmit the modifications. See Table of contents for information regarding the user interface Subsequently wire sensors as well as unit and restart ALOHA. See Table of contents for more information on wiring examples and device types Check incoming data using the ALOHA data window. GSM strength and power supply! 2.4 Enclosure And Installation Installation, electric connection, initial setup and maintenance shall be performed by qualified personnel authorised by the manufacturer only. Avoid direct sunlight! The device shall be used according to the respective specifications only. Particularly avoid magnetic or electric fields in the vicinity of the unit. Observe proper installation! Observe existing legal or operational regulations! Incorrect use may cause injuries and/or damage the instruments! Do not operate the NivuLog on site without the protective cover The protective cover must not be rubbed with a cloth due to the risk of electrostatic charge! Do not remove protective cover and measurement cable within Ex zones! In Ex zones the requirements and notes covered by EN :2007 (explosion prevention and protection basic concepts and methodology) and CLC/TR 50404:2003 (avoiding electrostatic charge) shall be adhered to! NivuLog Rev. 02 as of Page 6 / 12

7 Operating conditions Temperature C C (Ex) Humidity %rh, non-condensing Protection rating... IP67 Air pressure... norm. ±10 % ATEX Specifications Approval:... TÜV-A 11ATEX0001X (94/9/EG) Logger... II 2G Ex ib IIB T4 Battery... II 2G Ex ib mb IIB T4 Dimensions NivuLog (w x h x d) x 240 x 100 mm Standard antenna (H) x 165 mm Omnidirectional antenna (H) x 30 mm Weight NivuLog g 2.5 Battery Charger NLM0LAD424 Status LED orange flashing... battery deeply discharged Obsolete if charging orange... charging green... fully charged Charge the battery using the NLM0LAD424 battery charger exclusively. Do not charge the battery within Ex zones! A typical charging procedure is finished within 10 hours. A new rechargeable battery achieves full capacity after approx. 3 full loading cycles. The capacity decreases with age. Charge and discharge the accumulator completely to avoid this effect. 2.6 User Interface The red status LED automatically indicates the status every 30 sec. (or with each key action) by flashing. The green status LED merely flashes briefly on modem activation. Status LED 0 x... transport lock (GPRS off, measurement off) 1 x... transmission OK 2 x... unknown transmission error Try again 3 x... last transmission faulty Contact support 4 x... standby (GPRS on, measurement off) 6 x... offline (GPRS off, measurement on) 7 x... SIM lock / no appropriate provider Unlock SIM Try again NivuLog Rev. 02 as of Page 7 / 12

8 8 x... no GSM network Find better antenna position 9 x... false PIN / 1 attempt remaining Insert SIM into mobile phone! 10 x... no GPRS connection / faulty settings Retry later Correct settings Change provider 11 x... no Device 2 Web server available contact support 12 x... faulty SIM card Check proper position and condition of SIM Replace SIM card Use the magnet to find the magnet switch. Status LED on Trigger the desired action by moving the magnet away after the signal sequence. Status LED after key action... flashing... setting up connection lit... GPRS/USB active 3 Device Classes 3.1 Product Family Device Class Features NivuLog 2 Ex Logger with 2 universal inputs NivuLog 4 Logger with 4 universal inputs NivuLog PCM Ex Logger for direct connection to PCM Pro NivuLog Rev. 02 as of Page 8 / 12

9 3.2 NivuLog 2 Ex / NivuLog 4 NivuLog NivuLog Standard Standard Lemo 4 2 Ex Pin wire plug use G 1 2 GND C VDC F 6 n/c +4VDC E 7 3 Input 1 D 2 4 Input 2 A 5 5 Input 3 B 4 6 Input 4 The on-time of the +14 VDC sensor power supply can be set in Device 2 Web. 0 = no sensor power supply max. 125 ma The +4 V DC power supply is directly connected to the battery without fuse Beyond 22.5 ma corresponding inputs become high resistive (= cutoff). B A G F C D E Standard (socket) Lemo (plug) 6 Input Operation Modes Current... 0/4..20 ma analog Digital... Status signal T ON/OFF >20 msec 1 / 0 threshold adjustable online Counter... interval or daily reset NivuLog Rev. 02 as of Page 9 / 12

10 3.3 Settings Measurement point Name... name of the measurement point Not relevant for allocation of instruments or data Instrument S/N... instrument allocation (!) Comments Comments... for free comments Measurement channels (depending on device type) Name... free channel name Mode/Interface... basic settings for measurement channel Invert......of measurement channel (digital channel) Impulse... value of a counter (for counters) Daily changeover... reset of the counter (for counters) %... measurement range of the sensor (for analog channel) Min..Max... range of indication for standard graphs Unit... physical unit of the channel Format... decimal places High level... high level for signal detection (for digital channel) Value high... threshold in case of increasing slope (for analog channel) Value low... threshold in case of decreasing slope (for analog channel) Hyst... reset at 100+/-x% of the threshold (for analog channel) E.g. hyst=10%... alarm at 100 reset at 90 WA..AL... warning/alarm (for digital channel) Alarm Alarm mode... determines if alarms are to be confirmed manually Time stamp and user will be saved Offline alarm... determines if two transmission failures are to be signalised Transfer volume alarm... determines if exceeding the transfer volume by x% is to be signalised Alarm /sms... recipient list (separated by semicolon) R..Q... determines which condition triggers which action R record; T transmission; Q quick record Basic settings (depending on device type) Transmission interval... time period between transmission events Measurement interval... time period between measurements Factor rapid... measurement interval / factor as from triggering Warm-up time... starts the power supply x sec. prior to measuring Time zone/dst... regional settings Not relevant for raw measurement data (will be saved using in UTC) Position interval... time period between position updates NivuLog Rev. 02 as of Page 10 / 12

11 3.4 Optimum Antenna Position External influences on the signal quality Iron cover... up to -30 dbm Concrete cover... approx. -10 dbm Environmental influences... up to -15 dbm Installation height of antenna... approx. -5 dbm per 15 cm Vertical/horizontal... approx. -10 dbm Horizontal position... up to -15 dbm Manhole centre / wall... approx. -10 dbm Other... transmission performance of provider etc. Practical examples (open manhole cover) -67 dbm IIIII Reference measurement (out of manhole) -103 dbm Measuring in a depth of 1.20 m -95 dbm I Vertical on manhole wall (depth approx. 15 cm) -83 dbm III Manhole centre horizontal (iron holder) -89 dbm II Antenna rotated by dbm IIII Manhole centre vertical -75 dbm IIII Installed on plastic holder Possible installation options Antenna installation through drill hole in concrete ring (to avoid iron cover) Antenna installation through existing ventilation or supply pipe special types of antennas (e.g. manhole antenna, beam antenna, GSM repeater, ) Place antenna in manhole as described above. Make sure to have an antenna extension available. Start ALOHA using the magnet. Monitor measurement data via Device 2 Web using WAP, laptop, iphone or similar and adjust antenna position if required. It is recommended to maintain a performance headroom of 15 dbm. NivuLog Rev. 02 as of Page 11 / 12

12 4 Certificat The approval is only valid in connection with the respective indication on the data logger nameplate. The complete Ex approval is available on NivuLog Rev. 02 as of Page 12 / 12

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Data Acquisition Networks. Installing and Configuring the DM01 Hardware Data Acquisition Networks Installing and Configuring the DM Hardware What is the DM? D.A.N developed the DM-2 to capture 6 analogue measurements and pulse count in the field. The Average, Maximum and Minimum

More information

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT Universal Control Unit UC-1-E User Manual General Information Universal Control Unit UC-1 Of Central Lubrication CC DC 24 V 5A / M 15 SL /MK 31 M Z 30 General Information Contents Universal Control Unit

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

SM-10 SAT Level Meter User s Manual

SM-10 SAT Level Meter User s Manual SM-10 SAT Level Meter User s Manual DAGATRONICS CORPORATION 263-1 DUCKIDONG, ILSAN, KOYANG, KYUNGKIDO, KOREA TEL: +82-31-916-8005 FAX: +82-31-916-8080 Email: dagatron@dagatron.com Website: www.dagatron.com

More information

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017 M150SP USER S AND INSTALLER S MANUAL v2.0 REV. 03/2017 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE DEVICE TECHNICAL SPECIFICATIONS VISUAL ASPECT CONNECTORS

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

2.4GHz Digital Wireless Video Door Phone User Manual

2.4GHz Digital Wireless Video Door Phone User Manual 2.4GHz Digital Wireless Video Door Phone User Manual Thank you for purchasing our product. For better taking advantage of the prior functions please carefully read user manual for correct installation

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 27 mm without plug-in

More information

Standard signal metering in wall-mounting case

Standard signal metering in wall-mounting case User manual AKV-2VR4C Standard signal metering in wall-mounting case Technical features: Digit height: 20 mm Colour: red Range of display: -999 9999 Wall-mounting case: black, made of ABS-plastic Protection

More information

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C Galltec ess- und Regeltechnik GmbH EA ensortechnik GmbH D-71145 Bondorf. Germany D-07987 ohlsdorf-teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0. Fax +49(0)3661-62704-20

More information

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd.

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd. User Manual V2.6 Omniksol WIFIKIT User Manual Omnik New Energy Co., Ltd. Overview of WIFIKIT Function Omniksol-WIFIKIT is developed by Omnik as an external communication monitoring device, which integrates

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

Redcare signal strength tester user manual.

Redcare signal strength tester user manual. Redcare signal strength tester user manual. Page 1 Issue Apr 2012 Product description. The redcare GSM/GPRS Signal Strength Tester has been developed to help Security and Fire Alarm installers or engineers

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features: M1_61GB.pdf update: 17.09.2014 72x36 User Manual M1 Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC Technical features: red display of -1999 9999 digits (optional: green, orange or blue

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: from 63 mm with plug-in

More information

GC30 Digital Differential Pressure Gauge Operation Manual

GC30 Digital Differential Pressure Gauge Operation Manual TY-GC30-001A GC30 Digital Differential Pressure Gauge Operation Manual NAGANO KEIKI CO., LTD 2004.02.12 For safety of use TY-GC30-001A In order to safely and correctly utilize this device, please read

More information

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01 100KSPS 16-bit Analog Unit for USB AI-1664LAX-USB * Specifications, color and design of the products are subject to change without notice. This product is a USB2.0-compliant analog input unit that extends

More information

EB 3000 as of Version 1.7

EB 3000 as of Version 1.7 E35.0.01.6C-05 Manual for connection and operation of the EB 3000 page 1 of 14 Manual for connection and operation of EASYBus-control, display and supervisory device EB 3000 as of Version 1.7 GHM Messtechnik

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

HDCVI Camera User s Manual

HDCVI Camera User s Manual HDCVI Camera User s Manual Version 1.0.0 Table of Contents 1 General Introduction... 1 1.1 Overview... 1 1.2 Features... 1 2 Device Framework... 2 3 Device Cable Structure... 4 4 Device Installation...

More information

Manual. Simrad IS80 Heading Repeater HR80. English

Manual. Simrad IS80 Heading Repeater HR80. English Manual Simrad IS80 Heading Repeater HR80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Heading Repeater HR80 English Document no: 20223194 Revision:

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON CH+ CH- TABLE OF CONTENTS SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS and FEATURES ACCESSORIES and LOADING BATTERIES REMOTE CONTROL UNIT FRONT PANEL and REAR

More information

Multi-functional safety relay modules PROTECT SRB-E

Multi-functional safety relay modules PROTECT SRB-E Multi-functional safety relay modules PROTECT SRB-E PROTECT SRB-E The configurable User-friendly Up to 16 different applications can be selected Monitoring of all conventional safety switchgear Safety

More information

Indoor/Outdoor Security System with Quad Monitor User s Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual Indoor/Outdoor Security System with Quad Monitor User s Manual 4919539 Important! Please read this booklet carefully before installing or using these units. WARNING - These units should ONLY be opened

More information

Part names (continued) Remote control

Part names (continued) Remote control Introduction Part names (continued) Remote control (1) STANDBY ( 25) (1) (2) ON ( 25) (3) (3) ID - 1 / 2 / 3 / 4 s ( 18) (4) (4) COMPUTER 1 ( 27) (7) (5) COMPUTER 2 * (8) (6) COMPUTER 3 * (10) (13) (7)

More information

Installation Instructions

Installation Instructions SuperBus 2000 Concord 4 GSM Module 466-2262A October 2006 Copyright 2006, GE Security Inc. Introduction This is the GE SuperBus 2000 Concord 4 GSM Module Installation Instructions for part number 600-1053.

More information

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator 3.635.5275.254 IM-P486-18 CH Issue 3 PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9110 Portable Airborne Particle Counter (particle counter). This guide will help you

More information

Simply clever! The digital DIN-rail time switches by Grässlin

Simply clever! The digital DIN-rail time switches by Grässlin Simply clever! The digital DIN-rail time switches by Grässlin talento pro Trends and developments on the market. Maximum energy efficiency at low efforts In a saturated fast-moving market, the trend towards

More information

VNS2200 Amplifier & Controller Installation Guide

VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the

More information

PSM-003. Micro Polarization Controller/Scrambler. User Guide

PSM-003. Micro Polarization Controller/Scrambler. User Guide PSM-003 Micro Polarization Controller/Scrambler User Guide Version: 1.0 Date: August 23, 2012 General Photonics, Incorporated is located in Chino California. For more information visit the company's website

More information

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE Product code: TVRGBDSYA0 Syncroled Master receiver 0mA TVRGBDSYM0 Syncroled receiver 0mA TVRGBDSYB0 Syncroled Master receiver 00mA TVRGBDSYN0 Syncroled

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

User Manual For X3-H0402 MDVR. Mobile Digital Video Recorder. User manual for X3-H0402

User Manual For X3-H0402 MDVR. Mobile Digital Video Recorder. User manual for X3-H0402 User Manual For X3-H0402 MDVR Mobile Digital Video Recorder Copyright 2013-2015, Streamax Technology Co., Ltd All Rights Reserved 1 For more information, please visit our website www.en.streamax.com Notice

More information

Safety Light Curtain C 4000

Safety Light Curtain C 4000 O P E R A T I N G I N S T R U C T I O N S Safety Light Curtain C 4000 Operating Instructions Chapter 2 On safety 2 On safety This chapter deals with your own safety and the safety of the equipment operators.!

More information

Documentation on all Paxton products can be found on our web site -

Documentation on all Paxton products can be found on our web site - 11/05/2012 Ins-30202-US Net2 Entry - Monitor Paxton Technical Support 1.800.672.7298 supportus@paxton-access.com Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST) Documentation

More information

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216 Light Program Controller VLC-3 USER'S MANUAL +50,1 +50,1 1 : $ ' 2 7. 6 8 ' 5, 7 6 6. $ ( 3 352*5$0 0,16(& )81&7,216 6(77,1*6 & 8 5 5 ( 1 7 3 ( 5, 2 ' M 890-00189 rev. 04 K 895-00406 rev. 00 GENERAL...

More information

REGO Start&Go USER MANUAL

REGO Start&Go USER MANUAL REGO Start&Go USER MANUAL Version 0 Rev. B of 03/03/16 Page 1 of 15 Introduction The purpose of the manual is to describe all of the steps required to commission and correctly operate the REGO Start&Go

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

Tebis application software

Tebis application software Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF device WYC42xQ

More information

VNS2210 Amplifier & Controller Installation Guide

VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation 1. Determine the installation location for the VNS2210 device. Consider the following when determining the

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

OPERATING INSTRUCTIONS TOM-0431IP

OPERATING INSTRUCTIONS TOM-0431IP OPERATING INSTRUCTIONS TOM-0431IP Table of Contents FCC Information -------------------------------------------------------------------- 2 Safety and Environmental Precautions ------------------------------------------------

More information

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA The JS007WQK is loaded with userfriendly features and is ideal for use in heavy duty vehicles.

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

RMS 8424S Quick Start

RMS 8424S Quick Start VIEWSIZE THE WORLD RMS 8424S Quick Start Standard 4 unit rack mount size 8 inch LCD 2 1024 3 (RGB) 600 16:9 / 4:3 adjustable SDI/HDMI embedded audio output via 3.5mm earphone socket Support SDI/DVI audio

More information

TRF STEP-DOWN TRANSFORMER USER MANUAL

TRF STEP-DOWN TRANSFORMER USER MANUAL TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies

More information

Dell Wyse 5030 PCoIP Zero Client

Dell Wyse 5030 PCoIP Zero Client Dell Wyse 5030 PCoIP Zero Client User Guide Regulatory Model: PxN Regulatory Type: PxN001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

LCD Thermometer / Clock S No. 1253

LCD Thermometer / Clock S No. 1253 Installation and Operating Manual LCD Thermometer / Clock S No. 1253 The 3 fold thermometer with crystal clock is purpose build for the mounting in caravans, boats and intervention vehicles. Please read

More information

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV REV. 1.0 Fully ly Automaticti Motorised Satellite t TV System User s manual Customer Help Line: 1300 139 255 Support Email: support@satkingpromax.com.au Website: www.satkingpromax.com.au www.satkingpromax.com.au

More information

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE Product code: RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE TVRGBDMX88ST A Master receiver with DMX/DALI Slave TVSMX000A0 input TVRGBD000ST A Slave receiver -Vdc power supply IN P P P Led Led Led

More information

FOM-9010, FOM-9011 and FOM-9012

FOM-9010, FOM-9011 and FOM-9012 Control and Alarm Voltage sense, open collector, or contact inputs Features: FOM-00: Voltage Sense, Open Collector, or Dry Contact Inputs. State Detection for TIA-, TIA-, and TTL Signals. FOM-0: SPDT Form

More information

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO ALARM VERIFICATION UNIT VIVER VIDEO ALARM VERIFICATION UNIT VIVER viver_en 09/08 The VIVER module provides remote video alarm verification, based on image sequences transmitted from cameras installed in the protected facility. The

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION WIRELESS LIGHTING MODULE LIGHT AIR SWITCH User Manual and Troubleshooting Guide ACKNOWLEDGEMENTS P2 SAFETY WARNINGS EQUIPMENT DESCRIPTION P2 P2 1 ACCESSORIES/ASSOCIATED PARTS TECHNICAL CHARACTERISTICS

More information

USER MANUEL. SNIPE 2 Ref R13

USER MANUEL. SNIPE 2 Ref R13 USER MANUEL SNIPE 2 Ref. 0141317R13 Contents 1. General Information 1-1. Introduction 1-2. Proper use and operation 1-3. Safety notes......... 2 3 3 2. Contents 2-1. Accessory included 2-2. Name of parts......

More information

User Manual MDVR8041. User Manual. Mobile DVR MDVR Digital Video Recorder. Copyright , Meriva Security All Rights Reserved

User Manual MDVR8041. User Manual. Mobile DVR MDVR Digital Video Recorder. Copyright , Meriva Security All Rights Reserved User Manual Mobile DVR MDVR-8041 Digital Video Recorder Copyright 2013-2016, Meriva Security All Rights Reserved 1 Notice User Manual MDVR8041 The information in this manual was current when published.

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

Making Connections ANT Connect an outdoor VHF/UHF antenna or cable. TV JACK ANT 1 DVB-T/T2/C or (not included) Outdoor Antenna Antenna Cable (75Ω) Cable ANT OUT VHF/UHF Antenna ANT Connecting a satellite

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

application software

application software application software application software Input products / Shutter Output / RF output Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF

More information

User Guide. Centrex Recording Interface

User Guide. Centrex Recording Interface User Guide Centrex Recording Interface Table of Contents Introduction... 2 The Meridian Business Set... 3 Key Numbering Plan (18 button add-on)... 4 Key Numbering Plan (36 button add-on)... 5 Key Numbering

More information

Single cable multiswich programmer PC102W

Single cable multiswich programmer PC102W Single cable multiswich programmer PC102W 1. Product description The PC102W - single cable multiswich programmer (in the text - programmer) is useful instrument while configuring and troubleshooting SAT

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DVIS. DVIS - Digital Video Insertion System. Quick Start Guide. Patent Pending

DVIS. DVIS - Digital Video Insertion System. Quick Start Guide. Patent Pending DVIS Patent Pending DVIS - Digital Video Insertion System Quick Start Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments

More information

NIGHT WATCHER NW 760 QUICK SETUP GUIDE

NIGHT WATCHER NW 760 QUICK SETUP GUIDE 1 NIGHT WATCHER NW 760 QUICK SETUP GUIDE MOTORIZED LED FLOOD LIGHT WITH WI-FI CAMERA Please read these instructions carefully prior to installation and retain them for future reference. Failure to follow

More information

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion.

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNE; Please Read all of these instructions regarding

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Product information. Front-door station series with video for surface-mount

Product information. Front-door station series with video for surface-mount Product information Front-door station series with video for surface-mount series VPES series VPDS 2 05/2006 Table of contents Scope of delivery...3 Safety notices...3 General notes on the cabling in TCS

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide VBOX III 100Hz GPS Speed Sensor User Guide Page 1 of 21 VBOX III OVERVIEW... 3 INTRODUCTION... 4 FEATURES... 4 STANDARD INVENTORY... 5 OPTIONAL ACCESSORIES... 5 OPERATION... 6 GETTING STARTED... 12 VBOX.EXE

More information

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DLP600M 6+1 Relay Module for Heating and Cooling Plants Product Sheet TH6.25 Thermostat Type DLP600M DLP600M 6+1 Relay Module for Heating and Cooling Plants The DLP 600 M is a relay module for activation of loads (namely thermal actuators or circulators) in

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

Winmate Communication INC.

Winmate Communication INC. 20.1 Military Grade Display Model: R20L100-RKA2ML User s Manual Winmate Communication INC. May, 2011 1 IMPORTANT SAFETY INSTRUCTIONS Please read these instructions carefully before using the product and

More information

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS Installation Instructions Contents 1.0 Introduction...3 2.0 Safety...3 3.0 In the box...4 4.0 Installation of sensors...5 5.0 Linking transmitter

More information

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual TDEPD Field-Programmable Pressure Switch/Transducer with Integrated LED Display Programming Sequence Manual Wiring Diagram Pin5 Maintenance Mode + Gray Vent Pin2 Digital Output 2 +/ Analog Output + White

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

DRAFT RELEASE FOR BETA EVALUATION ONLY

DRAFT RELEASE FOR BETA EVALUATION ONLY IPM-16 In-Picture Audio Metering User Manual DRAFT RELEASE FOR BETA EVALUATION ONLY Ver 0.2 April 2013 1 Contents Introduction...3 In Picture Audio Meter Displays...4 Installation...7 External Audio Board

More information

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection Model ED 400 Drying and heating chambers Classic.Line with natural convection BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior

More information

PLL2210MW LED Monitor

PLL2210MW LED Monitor PLL2210MW LED Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending DVISm Patent Pending DVISm - Mini Digital Video Insertion System Quick Start Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is

More information