Sound Equipment Sound Control Room

Size: px
Start display at page:

Download "Sound Equipment Sound Control Room"

Transcription

1 Sound Equipment Sound Control Room National Theater & Concert Hall _ Theater _sound&video technical information Mixer STUDER VISTA Channel 24 Line Channel 8 Master mono 8 Group stereo 0 Aux mono 4 Aux Stereo CD-RW TASCAM CD-RW For recording use, recording fee please see the Venue rental Handbook. CD player TASCAM CD-0UPRO 2 For performance audio playback Monitor GENELEC 8050A 2 Wireless Microphone SHURE ULXP4 6 Extra rental fee is required. Please see the Venue rental Handbook. Main Speaker System & Audio Signal Circuits Item Brand / Type Amount Location Note Main House Speaker Meyer S- (PROCESSOR) 8 System : (Can be set for Meyer B-2E 4 Left, Center, Right or mono channel output). (PROCESSOR) Meyer CP-0 (EQ) 5 audio control Audio Distribution 5 room Amplifier CREST AUDIO Meyer MSL-2A (S-) 26 Stage Meyer 650-R2 (B-2EX) 4 Proscenium Microphone circuits MULTI Cable Network 6 circuits for each set (A & B) Belden Cat6 RJ45 outlet Around the stage area From stage to row 8 in the auditorium See appendix for the position chart SD- Fibre TELDOR 4C SM CABLE /SC adapter 40 Stage Monitor & Speaker Item Brand / Type Amount Location Note Down stage Monitor Amplifier CREST Audio 900+Meyer S- 2 speakers (Can be set Room as L&R or Mono Amplifier channel output) Meyer M-A (PROCESSOR) 2 Room Meyer UPA-C 2 Both sides of Stage Tower Normal set up a fixed position

2 Suspension Microphone Brand Type Amount Location Note SCHOEPS MSTC64g Stage overhead Dead hung suspended microphones for monitoring and recording use Microphone Brand Type Amount Location Note NEUMANN U87AI 4 Condenser Supply to the National NEUMANN KM-84 4 Condenser AKG D330BT 0 Dynamic AKG C Condenser AKG C562BL 3 Condenser AKG D2 4 Dynamic AKG C44B-XLS 8 Condenser SHURE SM57 0 Dynamic SHURE SM58 0 Dynamic SHURE BETA 57A 6 Dynamic SHURE BETA 58A 5 Dynamic SHURE BETA 9 2 Dynamic SHURE PGDMK6-XLR set For Jazz drum set SENNHEISER MD-44U 2 Dynamic 6 Condenser SENNHEISER MKH-70 SHOTGUN CROWN PCC-60 5 Condenser SCHOEPS CMC6+MK4g 2 Condenser Experimental Theatre and Recital Hall, the rental fee please see " Venue Rental Handbook " Mixer, EQ, Effect, & Sound Processor Compress / Limiter dbx 60A 4 Supply to the National dbx Expander dbx Graphic Equalizer Klark Teknik DN360 4 Parameter Equalizer Klark Teknik DN40 4 TC Electronic M3000 Effect Lexicon PCM9 3 YAMAHA SPX2000 Delay TC Electronic D2 5 Signal converter Klark Teknik DN00 5 MIDAS VENICE 320 Analog mixing console MIDAS VENICE 240 MIDAS VENICE 60 2 Digital mixing console YAMAHA PM5D YAMAHA M7CL 2 YAMAHA O2R96 Experimental Theatre and Recital Hall, the rental fee please see "Venue Rental Handbook"

3 Loud Speaker & Stage Monitor Active speaker-wide MEYER SOUND UPA-P 6 Supply to the National angle MEYER SOUND UPJ-P 4 Active speaker-stage Experimental Theatre MEYER SOUND UM -P 6 monitor and Recital Hall, the Active subwoofer rental fee please see MEYER SOUND USW-P 2 speaker "Venue Rental Active front fill Handbook" MEYER SOUND UPM-P 4 speaker Active speaker monitor YAMAHA MSP5A 3 Microphone Stand Item Factory / Type Amount Note AKG ST cm extension arm AKG ST cm extension arm PHILIPS T 0 Intercom System Item Brand / Type Amount Location Note Stage manager desk Intercom system main station Wireless Intercom system main station (include 8 portable wireless sub-station) Intercom system substation (with build in microphone & speaker) Clear-Com SB440 WP-2 (connection circuit) 24 Clear-Com WBS Clear-Com KB-22 5 Clear-Com KB2 6 Intercom system substation Clear-Com RS-50 Portable station Clear-Com RS-60 Single ear headset Beyer DT DSR side stage Stage manager desk See appendix for the position chart SD Stage manager desk Stage manager room, F & 2F backstage area Audio, Lighting, Video, & Rigging Control booth Broadcasting to auditorium & dressing rooms There are intercom system connection circuits in both center of the auditorium row 8, 4 and 3F, for load in & rehearsal period technical use. Extra rental fee is required, please see Theater rental reminder.

4 SD- Theater Sound & Microphone Circuit dispose chart

5 SD-2-_Theater_Intercom_System_Dispose_Chart SD-2-2_Theater_Intercom_System_Dispose_Chart

6 Video System Camera Set National Theater & Concert Hall _ Theater _sound&video technical information Image signal view waveform vector monitor Camera power supply IKEGAMI BSF-55 Video Camera(x22 lens) IKEGAMI HK-79GX OCP-399.Set on the back of the auditorium 2.Single camera 3.HD/SD-SDI&Composite output 4.For BD DVD video output for file ecording performing group monitoring and late audience watching. 5. Please note that the relevant fee will be used in accordance with the Venue Rental Handbook PROTECH HDF-700 HD LCD waveform monitor Pioneer DVR-630H 2 Provide program video recording service, the service rate please see DVR Recorder Pioneer DVR-lx70 the Venue Rental Handbook" Pioneer DVR-7000 Video Monitor 7 吋 LCD HDTV HLM- 704WR Recording Monitor 9 吋 LCD HDTV HLM WR Monitor speaker YAMAHA NS-0M STUDIO DVD player Pioneer DV 490V for program information clips playback RF Converter WINERSAT WAM-860SL 2 Convert the video image signal to RF signal for both back stage & FOH TV monitors. CH.09:Backstage area CH.0:FOH area, for program information clips playback Stage Monitor System(MATV) Location Brand / Type Amount Note F FOH Lobby Right & Left sides CHI MEI LCD 50" 2 Provide the stage image 2F FOH Lobby Right & Left sides CHI MEI LCD 40" 2 3F FOH Lobby Right & Left sides CHI MEI LCD 40" 2 4F FOH Lobby Right side CHI MEI LCD 40" 2 F Stage right & left side stage CHI MEI LCD 32" 40" 2 F Backstage right standby area CHI MEI LCD 40" F Backstage standby area CHI MEI LCD 40" F Lighting control booth SAMPO LCD 20" F Audio control booth SAMPO LCD 20" F Stage manager room CHI MEI LCD 42" 2F Stand by area CHI MEI LCD 50" F Stage Manager desk PANASONIC LCD 32" SONY LCD 9" for the backstage monitors and latecomers.. Provide the conductor image for the backstage monitors. (HIKVISION 080P CAMERA)

7 LED Subtitle Machine, Projector, Projection Items Brand/ Type Amount Note LED Subtitle Machine 6 words set Supply to the National 6000 ANSI lumen ( Contains standard lens.8-2.4:) Another can be replaced.3-.8: lens two Panasonic PT-D5700U ANSI lumen EPSON EB ANSI lumen EPSON EB-4950WU(HD) ANSI lumen SONY VPL-SX535(( Short focus type )) 2 80"Front Projection DA-LITE SP-80 4 Pneumatic cylinders 80 cm *35 cm 00" Front Projection DA-LITE SP-00 4 Pneumatic cylinders 24cm *63 cm 00" Rear Projection The Works E-Z 2 Folding Gray color 24 cm *63 cm 50" Front and Rear DA-LITE / Folding 2 Projection 305 cm*229 cm 20" Front and Rear Projection DA-LITE / Folding 427 cm *320 cm 300" Front Projection DA-LITE TRUSS DELUXE/ Folding 640 cm *488 cm Experimental Theatre and Recital Hall, the rental fee please see Venue Rental Handbook" Notebook Computer Items Brand/ Type Amount Note ASUS A8S 2 Supply to the National ASUS A8Ja ASUS X450J 2 Experimental Theatre and Recital Hall,the rental fee please see Venue Rental Handbook". The computer is for projecting performance images & information use only

National Theater_sound

National Theater_sound 03- 3 : Equipment 3 Control Room Item Brand/ Type Amount Note Mixer STUDER VISTA- 8 50 Channel 4 Line Channel 8 Master mono 8 Group stereo 0 Aux mono 4 Aux Stereo CD-RW TASCAM CD-RW000 For recording use

More information

Barbican Concert Hall Sound System Spec

Barbican Concert Hall Sound System Spec PA, FOH and Monitor System Main PA The system is predominantly Meyer Sound and is driven by two Meyer Sound Galileo 616 digital processors, which provide the time alignment and EQ for each part of the

More information

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee Audio Equipment (Audio Equipment Continued...) Console Cable MIDAS VERONA ( channels)

More information

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing) Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing) Technical requirements 1 Stages minimum stage dimensions 10x10 (other dimensions

More information

Dinkelspiel Auditorium - Technical Specifications

Dinkelspiel Auditorium - Technical Specifications Mailing Address Stanford Music Department 541 Lasuen Mall Stanford, CA 94305 Venue Address 471 Lagunita Dr Stanford, CA 94305 Production Coordinator Kevin Sweetser ksweets@stanford.edu House Specifications

More information

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall ALL INFORMATION SUBJECT TO CHANGE Last Updated 1/8/2015 THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall The striking art-deco interior of the 2,799-seat Mortensen Hall stands in contrast to

More information

Bloomington Center for the Performing Arts. Technical Specifications

Bloomington Center for the Performing Arts. Technical Specifications Bloomington Center for the Performing Arts Technical Specifications JOEL AALBERTS Performing Arts Manager (309) 434-2764 DAVID YOUNG Facility Manager (309) 434-2761 RODNEY W. STICKROD Technical Manager

More information

Hard Rock Cafe Times Square Sound System Advance Sheet

Hard Rock Cafe Times Square Sound System Advance Sheet Hard Rock Cafe 1501 Broadway New York, NY 10036 (212) 343-3355 t (212) 938-1901 f Hard Rock Cafe Times Square Sound System Advance Sheet FOH PA: Speakers: 8 - Clair Brothers R3T (4 ea. side) flown on sides

More information

Dr JOHN GALLAGHER CONCERT CHAMBER

Dr JOHN GALLAGHER CONCERT CHAMBER 1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Main Stage Technical Specs - Hall #2

Main Stage Technical Specs - Hall #2 Main Stage Technical Specs - Hall #2 Proscenium: - Height:...20' (06.10m) - Width:...31' 10"(09.70m) Apron: - Depth:...4' (01.22m) - Width:...45' 6" (13.87m) - Height:...3' 7" (01.09m) Stage: - Maximum

More information

General & Technical Specifications:

General & Technical Specifications: General & Technical Specifications: Physical Address: Seating Capacity Proscenium Opening: Stage Depth: Stage Width: Stage Height: Orchestra Pit: Stage Floor: Crossover: Loading Door: East side of San

More information

General & Technical Specifications

General & Technical Specifications General & Technical Specifications Physical Address: Seating Capacity Proscenium Opening: Stage Depth: Stage Width: Stage Height: Orchestra Pit: Stage Floor: Crossover: Loading door: NE San Carlos Street

More information

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS *** AVAILABILITY OF ALL ITEMS IS SUBJECT TO PRODUCTION ADVANCE. *** *** NO NOISE BEFORE 5PM DUE TO NEIGHBORHOOD NOISE ORDINANCE. *** Note: db limit @ FOH

More information

TECHNICAL REQUIREMENTS

TECHNICAL REQUIREMENTS BY CHRISTIANE JATAHY TECHNICAL REQUIREMENTS This technical file is the basic technical requirements for a standard venue. They are indicative and will be completed according to particular venues, by means

More information

Mics, DIs, Stands, and Cables

Mics, DIs, Stands, and Cables TALKING STICK RESORT Audio Main PA System is zoned as Left and Right with Aux fed Subs. Front fills, under balcony fills, VIP fills, and hearing assist are all sent from separate matrixes off of the console.

More information

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616) 1 Seating Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI 49544 Phone: (616) 647-0939 Fax: (616) 647-0149 Technical Specifications As of June 2009 Total Seating Capacity 756 + 4 wheelchair spaces

More information

Camden Opera House Theater. Technical Information

Camden Opera House Theater. Technical Information Camden Opera House Theater Camden Maine Technical Information Revised January 2018 The Camden Opera House is a multi-use Proscenium theater built in 1894 and renovated in 1994 that seats 489 people. The

More information

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet - 2018 Rooming List 03 DBL: Verônica Fernandes, Masako Tanaka Priscilla Azevedo, Marina Spoladore Carlos Fausto Brito, Rafael Duarte 02 SGL: Claudio

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Pentas 2 The Kuala Lumpur Performing Arts Centre (klpac) Updated: 15 th July 2017 Table of Contents 1. General - Stage - Back Stage / Stand-by Area - Dressing Rooms - Security 2. Staging

More information

US 2015/16 TECH RIDER

US 2015/16 TECH RIDER 1 US 2015/16 TECH RIDER 2 AFRO-CUBAN ALL STARS RIDER. NOTE: This document, whose content must be strictly followed by the PROMOTER, must be attached as an addendum to the contract and signed in all of

More information

UNIVERSITY CONCERT HALL. Technical Specification

UNIVERSITY CONCERT HALL. Technical Specification UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing

More information

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2016 Zach Vander Missen Muhammad Farooq Garrett McMindes Outline Primary System Design Constraints Venue Illustration System

More information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018 GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither

More information

Access to back stage is off Fletcher St on the eastern side of the building

Access to back stage is off Fletcher St on the eastern side of the building BYRON TECHNICAL SPECIFICATIONS JUNE 2013 VENUE OVERVIEW A studio style theatre with a capacity of 246, this venue is as pleasurable for performers as it is for the audience. The theatre is an ideal space

More information

HAROLD SHENKMAN HALL 2017 TECHNICAL SPECIFICATIONS

HAROLD SHENKMAN HALL 2017 TECHNICAL SPECIFICATIONS The 500-seat Harold Shenkman Hall is a fully serviced performance venue, which can be used to feature music, theatre, dance, choirs, conferences, film/video screenings, literary events, and other presentations.

More information

TECHNICAL SPECIFICATIONS LEPERCQ

TECHNICAL SPECIFICATIONS LEPERCQ TECHNICAL SPECIFICATIONS LEPERCQ Version: January 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636 4146 Fax: 718 857 166

More information

Technical Specifications

Technical Specifications Technical Specifications Updated Curatorial Statement is a Page 2 of 14 Theatre Stage Description: The Theatre is a flat floor space on the First Floor of the former Geelong Law Courts with 128 seat retractable

More information

Technical Specifications Nov 2016

Technical Specifications Nov 2016 Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The

More information

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860) THE MORTENSEN HALL 166 Capitol Avenue Hartford, CT 06106 The Bushnell Box Office: (860) 987-5900 The Bushnell Box Office FAX: (860) 987-6080 Administrative Offices: (860) 987-6000 Administrative fax: (860)

More information

Theatre Technical Specifications

Theatre Technical Specifications Theatre Technical Specifications The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Section A: Front of House (FOH) Public Address (PA) Speaker System

Section A: Front of House (FOH) Public Address (PA) Speaker System Annexure A TECHNICAL SPECIFICATIONS This annexure is a detailed list of the staffing and equipment that must be provided and professionally operated by the Sound Engineering Service Provider at every concert

More information

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience. The Stage Area The stage is a ground level trapezoidal shaped space with a proscenium arch and a curved apron forestage. A draped off rear stage provides a crossover. The rear stage can be separated using

More information

The Temple Hoyne Buell Theatre

The Temple Hoyne Buell Theatre The Temple Hoyne Buell Theatre Venue and Technical Guide The Temple Hoyne Buell Theatre The Temple Hoyne Buell Theatre is designed to provide the audience with a first-rate theatrical experience featuring

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Facility Information

Facility Information 20 Facility Information Please note: The information contained in this document is for planning purposes only and is subject to change at any time. The measurements contained herein are approximate. Please

More information

Summary. Access and Parking

Summary. Access and Parking 1 Summary Cornerstone arts centre consists of the main house which is 217 seat end on format with raked seating. An extra row (AA) of flat floor seating can be added giving a capacity of 234. The stage

More information

Matt Dann Cultural Centre

Matt Dann Cultural Centre Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:

More information

Technical Specification

Technical Specification Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com

More information

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK If the Client does not have any of these items or facilities available or cannot provide them precisely as specified, the Production Company

More information

ISLAND HALL TECHNICAL INFORMATION

ISLAND HALL TECHNICAL INFORMATION ISLAND HALL TECHNICAL INFORMATION Lagan Valley Island, The Island, Lisburn, BT27 4RL Telephone: 028 9250 9250 (Reception) If you have any queries regarding this technical information please contact either:

More information

Technical Capabilities of Towsley Auditorium updated February 2011 by WCC Media Services

Technical Capabilities of Towsley Auditorium updated February 2011 by WCC Media Services Technical Capabilities of Towsley Auditorium updated February 2011 by WCC Media Services Overview Towsley Auditorium hosts a wide variety of live events, from simple PowerPoint presentations to complex

More information

Technical Specification

Technical Specification Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium

More information

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre) Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

BITUSA 2019 General DRESSING ROOMS

BITUSA 2019 General DRESSING ROOMS Attention Marketing and Promotions Parties agree to make appropriate disclosure that artist is a celebrity impersonator and not the actual celebrity. The word "Tribute to" must be in all advertising. In

More information

2017 TECHNICAL SPECIFICATIONS

2017 TECHNICAL SPECIFICATIONS 2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au

More information

THEATRE EQUIPMENT DECEMBER 2017

THEATRE EQUIPMENT DECEMBER 2017 THEATRE EQUIPMENT DECEMBER 2017 Stage Stage opening (permanent): width 10m & height 6m Proscenium opening (adjustable): width 9m 11m Proscenium bridge: adjustable in height Working height underneath the

More information

Venue Information Liz Ferguson (385) Event Management Assistant

Venue Information Liz Ferguson (385) Event Management Assistant ABRAVANEL HALL 123 West South Temple Salt Lake City, Utah 84101 Phone: (385) 468-1030 Ticket Office Fax: (385) 469-1198 Web: www.artsaltlake.org Ticketing: www.arttix.org, 801-355-ARTS THEATRE STAFF Venue

More information

Scale of Hire Charges

Scale of Hire Charges Y Theatre Scale of Hire Charges Basic Charges & Miscellaneous Services Charges for Short-lease Facilities Version 2017.04.01 Major Facilities Y Theatre Y Theatre is located on the LG1/F & LG2/F of the

More information

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW The Haymarket Technical Specifications The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW Head of Production E: ruairi.mcnulty@anvilarts.org.uk T: 01256 819797 Ext: 118 Production and E: amanda.wise@anvilarts.org.uk

More information

Louis Koo Cinema Venue Specifications (updated 2018)

Louis Koo Cinema Venue Specifications (updated 2018) Louis Koo Cinema Venue Specifications (updated 2018) Louis Koo Cinema is professionally equipped for all kind of film shows, it can accommodate format of 16mm & 35mm film, high definition, digital, and

More information

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER Updated: June 27, 2011 TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER TELEPHONE NUMBERS: General Administrative Offices 253.591.5890 Production Stage Manager 253.591.5898 Facsimile 253.591.2027

More information

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5 Lighting -Lighting control PC with Horizon software and a 24 sub master wing. 2 Universes of DMX distributed via PathPort nodes. Our standard rep plot features 2 full stage back light washs of 20 PAR 64

More information

The Gallery bar has a glass fronted lockable fridge, storage space and a dial up Telecom line available for EFTPOS.

The Gallery bar has a glass fronted lockable fridge, storage space and a dial up Telecom line available for EFTPOS. INTRODUCTION We hope you find this document useful in outlining the venue and equipment details of The Meteor. Hamilton City Theatres is part of the Hamilton City Council and venue managers of Founders

More information

SHOWBOX SODO TECHNICAL SPECIFICATIONS

SHOWBOX SODO TECHNICAL SPECIFICATIONS SOUND FOH SPECS SHOWBOX SODO TECHNICAL SPECIFICATIONS *** AVAILABILITY OF ALL ITEMS SUBJECT TO PRODUCTION ADVANCE. *** AUDIO POWER 100amp 3 phase power on cam locks available for touring acts. This service

More information

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3 Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning

More information

Jane Mallet Theatre Technical Specifications

Jane Mallet Theatre Technical Specifications TECHNICAL SPECIFICATIONS Stage Technician Unions Stage I.A.T.S.E. Local 58 Stage Door Entrance Scott Street (West side of building South of Front St.) Seating Capacity Lower Orchestra 252 Cross Aisle*

More information

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram Get Funked Compact 6-piece Technical Rider 2017/18 Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram Contact Martyn Strange Tour Manager UK cell phone: +44

More information

Technical Specifications

Technical Specifications Technical Specifications Lighthouse Studio Version 4.1 13/05/16 Technical Services Coordinator: Xavier Dannock Phone number: 03 5559 4988 Mobile Number: 0402 973 030 Email address: xdannock@warrnambool.vic.gov.au

More information

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com PHOTO : SÉBASTIEN DION TECHNICAL RIDER A PROPERTY OF ADRESS 252, rue Saint-Joseph Est Québec (Québec) MANAGEMENT 240, rue Saint-Joseph Est Québec (Québec) G1K 3A9 General phone: 418.523.2227 FAX: 418.523.4449

More information

PRODUCTION BIBLE. last update November 2015

PRODUCTION BIBLE. last update November 2015 PRODUCTION BIBLE last update November 2015 FOR THE LATEST VERSION OF THIS DOCUMENT PLEASE DOWNLOAD IT FROM www.viperclub.eu/files/vipertheatre-productionbible.pdf We welcome you to the Viper theatre and

More information

Patriots Theater at the War Memorial Technical Data

Patriots Theater at the War Memorial Technical Data Patriots Theater at the War Memorial Technical Data Stage House Dimensions Proscenium Opening: 50-0 wide x 25-0 high Batten Travel: 48-10 Batten Length: 60-0 Stage depth: 26 smoke pocket to back wall Pit

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 02/06/2015 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

Technical Specification (Drama Theatre)

Technical Specification (Drama Theatre) Technical Specification (Drama Theatre) 1 TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Tickets will be sold through our ABC account and all tickets are scannable on entry. VENUE INFORMATION TICKETING We have NO daytime walk-in box office. Online: www.electricballroom.co.uk Tickets will be sold through our ABC account and all tickets are scannable on entry. The venue requires

More information

Monolake Live Surround 2011/2012

Monolake Live Surround 2011/2012 Monolake Live Surround 2011/2012 1. General Information Monolake Live Surround is an audio-visual multi-channel surround sound performance. It is the result of a lot of preparation and dedication. We will

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION PA SPECIFICATION LIGHTING PLAN LIGHTING SPECIFICATION PROJECTOR SPECIFICATION STAGE & MAIN HALL DIMENSIONS THEATRE SEATING PLAN CABARET SEATING PLAN GLASS STUDIO DIMENSIONS CAFÉ

More information

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre) Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Monty Kultuurfaktorij Technical Rider

Monty Kultuurfaktorij Technical Rider Monty Kultuurfaktorij Technical Rider Stage Sound Mixing consoles: 1x Soundcraft SI Performer Amplifiers: flightcaserack with: 1x Crown XTi 1000 1x Crown CTs 3000 + system controller EAW UX8800 flightcaserack

More information

Cornerstone Technical Specifications 2018 / V1

Cornerstone Technical Specifications 2018 / V1 Cornerstone Technical Specifications 2018 / V1 Cornerstone is a purpose-built, professional arts, culture and entertainment venue in the heart of Didcot, brought to you by South Oxfordshire District Council.

More information

TECHNICAL REQUIREMENTS

TECHNICAL REQUIREMENTS BY CHRISTIANE JATAHY TECHNICAL REQUIREMENTS This technical file is the basic technical requirements for a standard venue. They are indicative and will be completed according to particular venues, by means

More information

Information for Incoming Companies

Information for Incoming Companies Information for Incoming Companies The Stables Theatre Stockwell Lane Wavendon Milton Keynes MK17 8LU General The Stables is an internationally renowned music organisation with a vision to engage the widest

More information

The Haymarket Basingstoke Technical Specifications

The Haymarket Basingstoke Technical Specifications The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information

More information

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3 2017 Technical Specs updated: Jan 2017 Executive Director: Greg Ray Technical Director: Vonny Boarts Email: vonny@thestatetheatre.org www.thestatetheatre.org SEATING CAPACITY The State Theatre features

More information

The Taal Inc. Rhythm Ensemble Tech Rider

The Taal Inc. Rhythm Ensemble Tech Rider The Taal Inc. Rhythm Ensemble Tech Rider In case of any queries regarding sound please contact Janak on +91 9595 680 886 Email: janak@taalinc.net Please go through the full technical rider (including the

More information

Technical Specification (Drama Theatre)

Technical Specification (Drama Theatre) Technical Specification (Drama Theatre) 1 TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 14/08/2018 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

Music Hall of Williamsburg

Music Hall of Williamsburg Venue Info Music Hall of Williamsburg 66 North 6th St. (between Kent and Wythe) Brooklyn, NY 11249 Ph.718-486-5407 / Fax 718-486-5410 www.musichallofwilliamsburg.com Capacity 650 Parking We cannot reserve

More information

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM Auditorium Technical Specifications 1. Seating *fixed seating for 1508 *16 additional handicap access spaces 2. Stage

More information

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 (Revised October 2018) Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 PAC STAFF Director of Operations Andy Binder Production Manager Tom Kostusiak

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Technical Specifications (Concert Hall)

Technical Specifications (Concert Hall) Technical Specifications (Concert Hall) The provided information is accurate as of 12/04/2018 and is subjected to change without prior notice 1 TECHNICAL INFORMATION LOADING BAY The loading bay can be

More information

Technical Specification. Updated: April 2016

Technical Specification. Updated: April 2016 Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:

More information

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy Festival City Theatres Trust Festival Theatre Technical Specification Smoking Policy It is the policy of Festival City Theatres Trust that all of our workplaces are smoke-free and all employees and visiting

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 03/07/2015 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

PREMIERE HD SPECIFICATION SHEET DIMENSIONS (EXPANDED) DIMENSIONS GENERAL INFORMATION

PREMIERE HD SPECIFICATION SHEET DIMENSIONS (EXPANDED) DIMENSIONS GENERAL INFORMATION GENERAL INFORMATION Built by Gerling & Associates in 202 On-line in August 202 Travels with a 53 B Unit Trailer 20 Ton Hydrothirft A/C Units DIMENSIONS Length 53 Width 8 4 Height 3 5 Overall Length with

More information

SHUBERT THEATER 247 College Street, New Haven, CT

SHUBERT THEATER 247 College Street, New Haven, CT SHUBERT THEATER 247 College Street, New Haven, CT 06510 203-624-1825 TECHNICAL SPECIFICATIONS and EQUIPMENT INVENTORY HALL SEATING CAPACITY Orchestra 665 Mezzanine 474 Balcony 392 Boxes 60 TOTAL 1591 STAGE

More information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange

More information

QUAI BERIGNY DIEPPE CEDEX PHONE : FAX :

QUAI BERIGNY DIEPPE CEDEX PHONE : FAX : TECHNICAL REQUIREMENTS Update 03/15/16 QUAI BERIGNY 76374 DIEPPE CEDEX PHONE : 02.35.82.04.43 FAX : 02.32.90.00.34 SITE WEB : www.dsn.asso.fr D.S.N. Dieppe 1 TECHNICAL STAFF Technical Director : PIERRE

More information

Marjorie S. Deane Little Theater

Marjorie S. Deane Little Theater THEATER LOCATION Marjorie S. Deane Little Theater Public access at 5 West 63 rd street, New York, NY 10023. performances only at 10 West 64 th street. Directions to Loading Entrance at 10 West 64 th street:

More information

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Technical Rider. For more info : Simon Vaillancourt, Technical director (514) Technical Rider For more info : Simon Vaillancourt, Technical director (514) 572-3736 simon@clubsoda.ca Contact info 1225 Saint-Laurent Blvd., Montreal (Qc) H2X 2S6 Phone : 514-286-1010 Fax : 514-844-2571

More information

Technical Information

Technical Information 5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 27/02/2019 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

Technical specifications Main theatre. Sound

Technical specifications Main theatre. Sound Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 4 stereo line inputs 4 stereo Lexicon effects engines Stagebox: Soundcraft Mini Stagebox 32R 32 analogue inputs 8 analogue outputs 4 AES Out

More information

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building SEATING Auditorium seating capacity: Seats on main floor 732 Wheelchair seats 8 Obstructed view seating 0 Total 740 First row seats to edge of stage: 13 to seats STAGE Proscenium: Width 44 0 Height 18

More information

111 North 5 th Street Minneapolis, MN 55403

111 North 5 th Street Minneapolis, MN 55403 - 1-111 North 5 th Street Minneapolis, MN 55403 Venue Address Mailing Address: 111 North 5 th Street 510 1 st Avenue North Minneapolis, MN 55403 Suite 402 Minneapolis, MN 55403 Website www.millcitynights.com

More information

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE Wyllyotts Theatre, Wyllyotts Place, Darkes Lane, Potters Bar, Hertfordshire. EN6 2HN 1 Contents Pg. 3: Pg. 4: Pg. 5: Pg. 6: Pg. 7: Pg. 8: Wyllyotts Theatre

More information

Main House Technical Specification

Main House Technical Specification Main House Technical Specification Technical Stage Manager: Assistant Technical Stage Manager: Nearest train station: Christchurch Population: 47,300 Distance to London: 105 miles Shaun Luckly Tel: 01202