ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams

Size: px
Start display at page:

Download "ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams"

Transcription

1 ASE 369 K Measurements and Instrumentation LAB #9: Impulse-Force Hammer; Vibration of Beams Equipment: Dell Optiplex computer with National Instruments PCI-MIO-16E-4 data-acquisition board and the Virtual Bench Dynamic Signal Analyzer Impulse-Force Hammer (PCB 086C03) Piezoelectric Accelerometer (PCB 302A) Four-channel Amplifier/Signal Conditioner Unit (PCB 482A16 or PCB 482A22) Aluminum beam Objectives: To introduce you to the use of the impulse-force hammer to produce impact forces. To introduce you to the use of frequency response functions for determining the natural frequencies and mode shapes of a vibrating structure. 1 Dynamic Signal Analyzer (DSA) You used the DSA in the digital signal processing lab. You will use the DSA to conduct a spectral analysis of the acquired signals. Start out by loading the default.dsa file from the Edit load settings menu item. 2 Impulse-Force Hammer; Spectrum of an Impulse Impulse-force hammers are widely used in vibration testing to produce short-duration (i.e. impulse) forces and to measure the force produced. The experiments in this section: (1) illustrate the use of a hammer with attached force cell to produce an impulse force, and (2) illustrate the spectrum of the transient force produced by the hammer. The force cell is the piezoelectric type that is calibrated so that force can be obtained from the output voltage. The hammer has the following specifications: Frequency response range: 0 8 khz Max force: 500 lb Sensitivity: 10 mv/lb The hammer can be fitted with different hardness tips to enable the user to vary the duration of the impulsive loads. Note that only one side of the hammer has the piezoelectric cell, the other is for storing a different tip.

2 2.1 Assess the effect of hammer tip on the spectrum of an impulse force Install the soft red vinyl tip fitting on the force-cell end of the impulse-force hammer head. Only screw the tip in so that it is "finger- tight," that is, DO NOT use a wrench or pliers to tighten the tip; but, on the other hand, be sure that it is not loose The setup is shown in Fig. 1. Attach a BNC-to-BNC cable from the hammer handle to one of the four input channels of the PCB 4-channel Power Supply, which is to be shared between two lab stations. Attach a BNC-to-BNC cable from the output of the power-supply channel that you are using to ACH 0 of the BNC Set the gain of that power-supply channel to 10. Inputs (left column) outputs (right column) Dell Optiplex computer w/ Data-acquisition board and DSA software Figure 1. Experiment setup for impulse-force hammer measurements Set up the DSA by making the following selections: From the Edit menu: Input Settings: Input: Device = PCI-MIO-16E-4, Coupling = DC, Voltage Range = -10 to 10 V (for both channels); Windowing: Window A=none, Window B=none; Triggering: Type=Analog, Trigger channel=a, level=0.05 V. Frequency Settings: Baseband span = 2000 Hz, # of lines=400. Set up the display to show the time-waveform on Display 1 and the amplitude spectrum on Display 2. Have Display 1 show the real part and Display 2 the linear magnitude Holding the hammer still, but poised an inch or so above the desktop of the lab bench, press the SINGLE button on the DSA. At the top of the display you should see trigger wait,

3 which means it is waiting for the voltage to go above 0.05V before it triggers. Now, tap (NOT hit) the red tip of the hammer on the wood desktop. An impulse-like time history should appear in Display 1. If that does not happen, press RUN rather than single and try again (the problem with RUN is that you can lose your displayed data if you inadvertently cause a trigger, such as by putting the hammer down). If that still doesn t work ask your Lab Instructor for assistance. Once you have the time history and the spectrum of the signal produced by the red hammer tip, save Displays 1 and 2 to files Change the baseband span to 4 khz by clicking on the label at the lower right of display 2. Remove the red vinyl tip to expose the white nylon tip and repeat Section Try to tap the desk with about the same force level that you used in Sect Natural Frequencies and Mode Shapes of a Cantilever Beam References: (1) Craig, R. R., Structural Dynamics An Introduction to Computer Methods, Sects. 9.2 and 10.2, John Wiley & Sons, New York, (2) Vibration of Beams Frequency Response, ASE 369K Class Notes, ASE-EM Department, The University of Texas at Austin, Spring In this laboratory exercise you will obtain three frequency response functions (FRFs), which constitute part of the data that would be taken in a modal test. These frequency response functions can be used to determine approximate values of the lowest two natural frequencies of the cantilever beam with tip mass (the accelerometer). The accelerometer will be mounted near the tip of the beam on the underside of the beam. The impulse hammer will be used to tap the beam at three locations -- location A, 2 in. from the tip of the beam, will emphasize mode 1; a hit at location B, 5 in. from the tip of the beam, will excite both mode 1 and mode 2, and a hit at location C, 8 in. from the tip of the beam, will also excite both mode 1 and mode 2. Clamp Beam Accelerometer

4 8 Clamp 5 2 C B A 3.1 Spectrum Analyzer Set-Up Keep the same trigger settings. Open the Edit menu and under frequency settings select baseband span= 2000 and # of lines = Beam, Accelerometer, and Impulse Hammer Set-Up Make sure that the aluminum beam is securely clamped in the bracket that is bolted to the steel loading frame. Measure the cross-sectional dimensions of the beam: w= in. and t in., and measure the length of the beam from the edge of the clamping bracket to the tip of the beam, L in. Assume that the modulus of elasticity for the aluminum beam is E= psi and that the weight density is 0.10 lb/in Attach the PCB accelerometer to the bottom side of the beam by tightly threading the short stud-bolt in the base of the accelerometer into the tapped hole near the end of the beam. Carefully attach a microdot-to-bnc cable from the accelerometer to the Channel 2 (or 4) INPUT of the PCB amplifier/signal conditioner. Set the amplifier gain of this accelerometer channel to k a = 10. Connect the amplifier OUTPUT of this channel to ACH1 of your BNC connector box Install a white-nylon/blue-vinyl tip on the impulse hammer force cell, and attach a BNC-to-BNC cable from the hammer to the Channel 1 (or 3) INPUT of the PCB amplifier/signal conditioner. Set the amplifier gain of this force channel to k f = 10. Connect the amplifier OUTPUT of this channel to ACH0 of your BNC connector box. Have the TA check your set-up of the beam, accelerometer, and hammer. 3.3 Time Histories of Impulse Force and Acceleration Acquire the time history of the impulse force and the time history of the acceleration of the tip of the beam as you strike (tap) the cantilever beam at three different locations.

5 Use SINGLE to arm the trigger each time (if that doesn t work use RUN) Display the time waveform of CH0 on Display 1. Choose to display the real part. This will display the impulse-force hammer output Display the time waveform of CH1 on Display 2.Choose to display the real part. This will display the accelerometer time-history Tap the center of the top surface of the beam 8 in. from the tip of the beam (location C). If you don't get a trigger, call on the TA to help you. There should be a single impulse peak (or perhaps double-humped peak) for the force signal, and the time history of the acceleration should appear to be the superposition of a high-frequency sinusoidal signal and a very low-frequency sinusoidal signal. When you think you have acceptable time histories of acceleration and force, show your graphs to the TA before continuing. Save both displays to files Tap the center of the top surface of the beam 5 in. from the tip of the beam (location B), using the same good technique you developed in Step There should be a single impulse peak for the force signal, and the time history of the acceleration should again appear to be the superposition of a highfrequency sinusoidal signal and a low-frequency sinusoidal signal. When you think you have acceptable time histories of acceleration and force, save the displays to files Tap the center of the top surface of the beam 2 in. from the tip of the beam (location A). There should be a single impulse peak for the force signal, and the time history of the tip acceleration should appear to be a low-frequency sinusoidal signal. Your force signal should not have several distinct peaks. (As you hit closer to the tip of the beam, it gets harder and harder to hit the beam only once. The beam can bounce back up and hit your hammer tip before your hand can pull the hammer back away from the beam.) When you think you have acceptable time histories of acceleration and force, show your graphs to the TA before continuing. Save both displays to files. 3.4 Impulse-Force Spectrum and Accelerance FRFs Use the thick plate for this section. Display the amplitude spectrum of the impulse-force hammer and also the frequency response function (FRF). The FRF is the ratio of the tipacceleration/impulse-force, or CH1/CH0 and has units of volts/volts Setup Display 1 as follows: CH0, amplitude spectrum, linear magnitude Setup Display 2 as follows: CH1, frequency response, linear magnitude. Change the baseband span to 400 Hz. This setup will cause Display 2 to display the FRF, i.e. acceleration/input-force.

6 Homework: Tap the center of the top surface of the beam 8 in. from the tip of the beam (location C), using the same good technique you used in Sect There should be a fairly smooth spectrum for the force signal, and the FRF should have a small peak at about 30 Hz and a larger peak at about 220 Hz. When you think you have an acceptable force spectrum and FRF, show your graphs to the TA before continuing. Save the displays to files Tap the center of the top surface of the beam 5 in. from the tip of the beam (location B). There should be a fairly smooth spectrum for the force signal, and the FRF should again have a peak at about 30 Hz and a peak at about 220 Hz. When you think you have an acceptable force spectrum and FRF, save the displays to files Tap the center of the top surface of the beam 2 in. from the tip of the beam (location A). There should be a fairly smooth spectrum for the force signal, and the FRF should have a large peak at about 30 Hz, but no peak (or only a very small one) at about 220 Hz. (If your force spectrum is very humpy, you probably allowed the hammer to make multiple hits. As you hit closer to the tip of the beam, it gets harder and harder, in fact, it gets virtually impossible, to hit the beam only once. The beam can bounce back up and hit your hammer tip before your hand can pull the hammer back away from the beam. Keep trying until you get a fairly smooth force spectrum.) Save the displays to files. 1. Using the sensitivity information of the force cell, plot on the same graph the force-time response for the red and white vinyl hammer tip. 2. From the impulse test, plot the amplitude spectrum of red and white vinyl hammer tip. Discuss your plots. 3. Plot both the time history and amplitude spectrum for the beam at the three different locations. Briefly describe your observations. 4. Plot the accelerance FRF s for the three positions on the beam. Briefly describe your plots. 5. Compare the theoretical vibrational modes to the measured vibrational modes (from the FRF). RRC, 11/94, Latest revision: 4/2003, NC Ravi, modified 01/2004

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods

More information

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO) 2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency

More information

9070 Smart Vibration Meter Instruction Manual

9070 Smart Vibration Meter Instruction Manual 9070 Smart Vibration Meter Instruction Manual Overall machine and bearing conditions: vibration values are displayed with color coded alarm levels for ISO values and Bearing Damage (BDU). Easy vibration

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

Activity P27: Speed of Sound in Air (Sound Sensor)

Activity P27: Speed of Sound in Air (Sound Sensor) Activity P27: Speed of Sound in Air (Sound Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Speed of sound P27 Speed of Sound 1.DS (See end of activity) (See end of activity) Equipment

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

Activity P32: Variation of Light Intensity (Light Sensor)

Activity P32: Variation of Light Intensity (Light Sensor) Activity P32: Variation of Light Intensity (Light Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Illuminance P32 Vary Light.DS P54 Light Bulb Intensity P54_BULB.SWS Equipment Needed

More information

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

Capstone Experiment Setups & Procedures PHYS 1111L/2211L Capstone Experiment Setups & Procedures PHYS 1111L/2211L Picket Fence 1. Plug the photogate into port 1 of DIGITAL INPUTS on the 850 interface box. Setup icon. the 850 box. Click on the port 1 plug in

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single

More information

OSCILLOSCOPE AND DIGITAL MULTIMETER

OSCILLOSCOPE AND DIGITAL MULTIMETER Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I Prepared by: Kyle Botteon Questions? kyle.botteon@psu.edu 2 Background Information Recall that oscilloscopes (scopes)

More information

SX7. Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY

SX7. Saga 7 Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY SX7 Quick Start Guide Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs What s Included 1 x Saga X7 Monitor 1 x V-Mount Plate (Attached) 1 x Mini-XLR to P-TAP Cable 1 x Dual Sony L Battery Adapter

More information

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color

More information

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes Product Manual MNX10015 / REV C MODEL SB142, SB242 Dual Output Series Switch Boxes Contents Section I Overview Introduction.... 2 Description... 2 Section II Installation Mounting... 3 Electrical Connections...

More information

Figure 1. MFP-3D software tray

Figure 1. MFP-3D software tray Asylum MFP-3D AFM SOP January 2017 Purpose of this Instrument: To obtain 3D surface topography at sub-nanometer scale resolution, measure contact and friction forces between surfaces in contact, measure

More information

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Lab 1 Introduction to the Software Development Environment and Signal Sampling ECEn 487 Digital Signal Processing Laboratory Lab 1 Introduction to the Software Development Environment and Signal Sampling Due Dates This is a three week lab. All TA check off must be completed before

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 9500B Users Supplement Issue: 2 Part Number: 1625019 Issue Date: 9/06 Print Date: October 2005 Page Count: 6 Version 11 This supplement contains information necessary to ensure the accuracy

More information

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1 4830A Accelerometer simulator Instruction manual IM4830A, Revision E1 IM4830, Page 2 The ENDEVCO Model 4830A is a battery operated instrument that is used to electronically simulate a variety of outputs

More information

Sound and Vibration Data Acquisition

Sound and Vibration Data Acquisition NI PXI-449x, NI PXIe-449x NEW! 16 simultaneous analog inputs 24-bit resolution 204.8 ks/s maximum sampling rate 114 db dynamic range +10, +20, and +30 db gains ±0.316, 1, 3.16, and 10 V input ranges Antialiasing

More information

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C A Electric Power / Controls 2 kw EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C GENERAL DESCRIPTION The Lab-Volt Data Acquisition and Management for Electromechanical Systems (LVDAM-EMS),

More information

Laboratory 6: Applications of a Digital Spectrum Analyzer to signal characterization

Laboratory 6: Applications of a Digital Spectrum Analyzer to signal characterization TELECOMMUNICATION ENGINEERING TECHNOLOGY PROGRAM TLCM 242: INTRODUCTION TO TELECOMMUNICATIONS LABORATORY Laboratory 6: Applications of a Digital Spectrum Analyzer to signal characterization Part 1.- Analysis

More information

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

NanoGiant Oscilloscope/Function-Generator Program. Getting Started Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose

More information

SLAB IMPULSE RESPONSE TEST NDE-360

SLAB IMPULSE RESPONSE TEST NDE-360 SYSTEM REFERENCE MANUAL 2008 SLAB IMPULSE RESPONSE TEST NDE-360 NOTICES Errors and Omissions This document is believed to be accurate, but Olson Instruments, Inc. will not be responsible for errors or

More information

Linear Probe Encoder Page 1 of 7. Description. Features

Linear Probe Encoder Page 1 of 7. Description. Features Page 1 of 7 Description The PE series linear plunger-style optical encoder has a machined aluminum enclosure. The PE provides either single-ended or differential quadrature encoder output in a convenient

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

Spectrum Analyser Basics

Spectrum Analyser Basics Hands-On Learning Spectrum Analyser Basics Peter D. Hiscocks Syscomp Electronic Design Limited Email: phiscock@ee.ryerson.ca June 28, 2014 Introduction Figure 1: GUI Startup Screen In a previous exercise,

More information

Practical considerations of accelerometer noise. Endevco technical paper 324

Practical considerations of accelerometer noise. Endevco technical paper 324 Practical considerations of accelerometer noise Endevco technical paper 324 Practical considerations of accelerometer noise Noise can be defined as any undesirable signal within the measurement chain.

More information

Stock Products. Over 10,000 Sensors In-Stock Ready to Ship!

Stock Products. Over 10,000 Sensors In-Stock Ready to Ship! 2013 Over 10,000 Sensors In-Stock Ready to Ship! Models Added PCB PlatinumAdded Stock Products Available With Our Lifetime Warranty and Fast Shipping At PCB Piezotronics, we appreciate the opportunity

More information

Lab experience 1: Introduction to LabView

Lab experience 1: Introduction to LabView Lab experience 1: Introduction to LabView LabView is software for the real-time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 PCB PIEZOTRONICS INC. 3425 Walden Avenue Depew, NY 14043 David J. Dulanski Phone: 716 684 0002 ext 2617 CALIBRATION

More information

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL DATA ACQUISITION SYSTEM V.15.4 INSTRUCTION MANUAL Timberline Instruments, LLC 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx:

More information

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

Experiment 13 Sampling and reconstruction

Experiment 13 Sampling and reconstruction Experiment 13 Sampling and reconstruction Preliminary discussion So far, the experiments in this manual have concentrated on communications systems that transmit analog signals. However, digital transmission

More information

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4... LVDT Inductive Position Transducer Series SM ø12 mm ranges 2...200 mm linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6 out: AC, 0...10 V, 0...5 V, 4...20 ma with external or integrated cable electronics repeatability

More information

Quick Start Bruker Dimension Icon AFM

Quick Start Bruker Dimension Icon AFM Do not remove Quick Start Bruker Dimension Icon AFM March 3, 2015 GLA Contacts Harold Fu (hfu@caltech.edu) Weilai Yu (wyyu@caltech.edu) Bruker Tech Support (AFMSupport@bruker-nano.com 800-873-9750) Watch

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

Instruction Manual for Electronic Blowers and Flashboards

Instruction Manual for Electronic Blowers and Flashboards Instruction Manual for Electronic Blowers and Flashboards These instructions cover both the table model 17212 table top Electronic Bingo Blower (Fig 1) and the 17213 floor model Electronic Bingo Blower

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

Personal Protective Equipment Wear nitrile gloves, lab coat, and safety glasses as a minimum protection, unless otherwise indicated.

Personal Protective Equipment Wear nitrile gloves, lab coat, and safety glasses as a minimum protection, unless otherwise indicated. 4pt Bending, Mouse This protocol is for standard Jepsen 4pt bending of adult mouse bone. Safety considerations Please reference the Jepsen laboratory when using this protocol. This protocol is subject

More information

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

G.R.A.S. Sound & Vibration

G.R.A.S. Sound & Vibration Instruction Manual Single-channel Low-noise Measuring System consisting of: ½-inch Low-noise Level Microphone System Type 40HH and Power Module Type 12HF 40HH 12HF G.R.A.S. Sound & Vibration Skovlytoften

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) 1. Log into the Log Usage system on the SMIF web site 2. Open Nanoscope 6.14r1 software by double clicking on the Nanoscope 6.14r1 desktop

More information

Foreword The SKF brand now stands for more than ever before, and means more to you as a valued customer. While SKF maintains its leadership as the hal

Foreword The SKF brand now stands for more than ever before, and means more to you as a valued customer. While SKF maintains its leadership as the hal SKF Microlog Accessories Catalog 资料整理 : Foreword The SKF brand now stands for more than ever before, and means more to you as a valued customer. While SKF maintains its leadership as the hallmark of quality

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS PARTS REQUIRED Parts in the box Single monitor Dual monitor M2 M8 M/Flex + (package contents will depend on configuration ordered) Tools required for installation 6.0 mm Hex Key

More information

Measurement of overtone frequencies of a toy piano and perception of its pitch

Measurement of overtone frequencies of a toy piano and perception of its pitch Measurement of overtone frequencies of a toy piano and perception of its pitch PACS: 43.75.Mn ABSTRACT Akira Nishimura Department of Media and Cultural Studies, Tokyo University of Information Sciences,

More information

LabView Exercises: Part II

LabView Exercises: Part II Physics 3100 Electronics, Fall 2008, Digital Circuits 1 LabView Exercises: Part II The working VIs should be handed in to the TA at the end of the lab. Using LabView for Calculations and Simulations LabView

More information

Experiment 9A: Magnetism/The Oscilloscope

Experiment 9A: Magnetism/The Oscilloscope Experiment 9A: Magnetism/The Oscilloscope (This lab s "write up" is integrated into the answer sheet. You don't need to attach a separate one.) Part I: Magnetism and Coils A. Obtain a neodymium magnet

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

Data Acquisition Using LabVIEW

Data Acquisition Using LabVIEW Experiment-0 Data Acquisition Using LabVIEW Introduction The objectives of this experiment are to become acquainted with using computer-conrolled instrumentation for data acquisition. LabVIEW, a program

More information

Subj: General MTI2000 and Piezo Task Setup and Operation. High-Voltage Displacement Meter (HDVM) Configuration.

Subj: General MTI2000 and Piezo Task Setup and Operation. High-Voltage Displacement Meter (HDVM) Configuration. 6 March 2013 Radiant Technologies, Inc. 2835D Pan American Freeway NE Albuquerque, NM 87107 Tel: 505-842-8007 Fax: 505-842-0366 e-mail: radiant@ferrodevices.com From: Scott P. Chapman Radiant Technologies,

More information

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions 1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions 1.1 Click on the OMNIC icon to open the software. 1.2 Check that a signal is being measured by opening the Experiment Setup menu under the Collect

More information

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Introduction The vibration module allows complete analysis of cyclical events using low-speed cameras. This is accomplished

More information

M2 Antenna Systems, Inc. Model No: 23CM35

M2 Antenna Systems, Inc. Model No: 23CM35 M2 Antenna Systems, Inc. Model No: 23CM35 SPECIFICATIONS: Model... 23CM35 Frequency Range... 1250 To 1300 MHz *Gain... 20.94 dbi Front to back... 25 db Typical Beamwidth... E=17 H=18 Feed type... Folded

More information

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR Introduction: The RMA package is a PC-based system which operates with PUMA and COUGAR hardware to

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Expect to Make Waves.

Expect to Make Waves. Expect to Make Waves. The New Oscilloscope Large 10.4" LCD touch screen Long capture time Extensive communication capabilities www.lecroy.com The New Oscillos From its large 10.4" LCD touch screen to its

More information

S7H-DK S7H 7" High Bright Monitor Deluxe Kit

S7H-DK S7H 7 High Bright Monitor Deluxe Kit S7H-DK S7H 7" High Bright Monitor Deluxe Kit QUICKSTART GUIDE What s Included 1 x S7H Monitor 1 x Camera Shoe Mount 1 x Neoprene Sleeve 1 x Mini-XLR to P-TAP Cable 2 x DV Battery Plate 1 x DV Battery 1

More information

Satellite Dish Installation Manual (Ver. 2) 1

Satellite Dish Installation Manual (Ver. 2) 1 Satellite Dish Installation Manual Provided by DiscoverNet, Inc. Satellite Dish Installation Manual (Ver. 2) 1 Table of Contents Section 1: Introduction Page 3 Section 2: Recommended Tools and Materials

More information

OZONESONDE FLIGHT PREPARATIONS

OZONESONDE FLIGHT PREPARATIONS OZONESONDE FLIGHT PREPARATIONS 2 Table of Contents Notes... 3 A week before flight preparations... 4 Changing the sensor solution... 4 Measuring background current... 5 Day of flight preparation... 7 Closing

More information

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM Purpose of this Instrument: To obtain 3D surface topography at sub-nanometer scale resolution, measure contact and friction forces between surfaces in contact,

More information

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION Troubleshooting Low Noise Systems April, 2015 Page 1 INTRODUCTION The exceedingly low level of electronic noise produced by the QCL family of drivers makes narrower linewidths and stable center wavelengths

More information

GOODMAN BENTLEY STEREOPHONIC STETHOSCOPE OPERATING INSTRUCTIONS

GOODMAN BENTLEY STEREOPHONIC STETHOSCOPE OPERATING INSTRUCTIONS GOODMAN BENTLEY STEREOPHONIC STETHOSCOPE OPERATING INSTRUCTIONS Individually handcrafted to the highest specifications by Goodman Bentley (Spec/Ops) Design & Security Company. Providers of covert Technical

More information

Lesson 10 Manual Revision BIOPAC Systems, Inc.

Lesson 10 Manual Revision BIOPAC Systems, Inc. Physiology Lessons for use with the Lesson 10 ELECTROOCULOGRAM (EOG) I Eye Movement Saccades and Fixation during Reading Manual Revision 3.7.3 061808 Vertical J.C. Uyehara, Ph.D. Biologist BIOPAC Systems,

More information

VOD/DATA RECORDERS AND ACCESSORIES FOR ASSOCIATED APPLICATIONS PRODUCT LIST

VOD/DATA RECORDERS AND ACCESSORIES FOR ASSOCIATED APPLICATIONS PRODUCT LIST VOD/DATA RECORDERS AND ACCESSORIES FOR ASSOCIATED APPLICATIONS PRODUCT LIST MREL DOCUMENT #: PROD180102 THESE PRODUCTS AND PRICES ARE AVAILABLE TO PRE-SCREENED, PRE-APPROVED CUSTOMERS ONLY. PRICES ARE

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. RST INSTRUMENTS LTD. MEMS Tilt Beam Instruction Manual Copyright 2012 Ltd. All Rights Reserved. Ltd. 11545 Kingston St., Maple Ridge, B.C. Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email:

More information

INSTRUCTION MANUAL. Vibration Meter Unit UV Higashimotomachi, Kokubunji, Tokyo , Japan

INSTRUCTION MANUAL. Vibration Meter Unit UV Higashimotomachi, Kokubunji, Tokyo , Japan INSTRUCTION MANUAL Vibration Meter Unit UV-15 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan http://www.rion.co.jp/english/ Organization of this manual This manual describes the features,

More information

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit DH7-DK QUICKSTART GUIDE DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit What s Included 1 x DH7 Monitor 1 x AC Adapter 1 x Camera Shoe Mount 1 x Screen Cleaning Wipe 1 x Screen Protection Film 1

More information

2 MHz Lock-In Amplifier

2 MHz Lock-In Amplifier 2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display

More information

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels DT9857E Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements

More information

MTL Software. Overview

MTL Software. Overview MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s

h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s h c HUNG CHANG http://www-hhvngchang.com Hongjc Bldg. 301-2, Hongje-dong. Seodaemun-ku, Seoul, Korea TEL : 82-2-395-8611-19 FAX : 82-2-395-5381184 D IBM PC 586, Pcntium Software Drive : Windows 95 Dual

More information

Test Report: Gamma Vibration & Shock

Test Report: Gamma Vibration & Shock SUBJECT: PRODUCT: GAMMA SHOCK, VIBRATION, AND THERMAL PERFORMANCE TOLTEQ RUGGEDIZED GAMMA DATE: JUNE 4, 2014 AUTHOR: PRODUCT DEVELOPMENT DEP SCOPE The purpose of this test is to establish a baseline of

More information

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

VXF7 QUICKSTART GUIDE. 7 4K Full HD HDMI/3G-SDI On-Camera Monitor VXF7 QUICKSTART GUIDE 7" K Full HD HDMI/G-SDI On-Camera Monitor What s Included x VXF7 Monitor x AC Adapter x Camera Shoe Mount (SM-0) x Screen Cleaning Wipe x Screen Protector x Sunhood x Canon E6 Battery

More information

Installing a MotoSat MD500 for Dish Network on a RB Born Free

Installing a MotoSat MD500 for Dish Network on a RB Born Free Installing a MotoSat MD500 for Dish Network on a 2005 24RB Born Free 1 2005 24RB July 2006 I have Dish network using satellites 110 and 119 and had decided on using the MotoSat MD500 rather than the dome

More information

A wireless turntable for new way of enjoying vinyl records

A wireless turntable for new way of enjoying vinyl records Bluetooth Turntable TN-280BT 2-speed Analog Turntable with Phono EQ and Bluetooth A wireless turntable for new way of enjoying vinyl records Main Features 2-speed Belt-drive turntable Built-in MM phono

More information

AX20. Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY

AX20. Atlas 19.5 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY AX20 Quick Start Guide Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes What s Included 1 x Atlas 19.5" Monitor 1 x AC Adapter 1 x Sunhood CHECKED BY AX20 FRONT 1920 x 1080 19.5 inch

More information

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS SERIES BNC 50, COAXIAL MINIATURE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER BNC is still one of the most popular connector series, featuring a two stud bayonet coupling mechanism, which is particularly

More information

A Simple Noise Measurement Amplifier and Filter

A Simple Noise Measurement Amplifier and Filter A Simple Noise Measurement Amplifier and Filter Scott Reynolds (TavishDad on diyaudio) Tavish Design, LLC (http://tavishdesign.com/) I have developed a simple op-amp circuit that makes it easy to measure

More information

medlab One Channel ECG OEM Module EG 01000

medlab One Channel ECG OEM Module EG 01000 medlab One Channel ECG OEM Module EG 01000 Technical Manual Copyright Medlab 2012 Version 2.4 11.06.2012 1 Version 2.4 11.06.2012 Revision: 2.0 Completely revised the document 03.10.2007 2.1 Corrected

More information

SOUND LABORATORY LING123: SOUND AND COMMUNICATION

SOUND LABORATORY LING123: SOUND AND COMMUNICATION SOUND LABORATORY LING123: SOUND AND COMMUNICATION In this assignment you will be using the Praat program to analyze two recordings: (1) the advertisement call of the North American bullfrog; and (2) the

More information

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B. LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution This lab will have two sections, A and B. Students are supposed to write separate lab reports on section A and B, and submit the

More information

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display PRJTPFL102-100 - inch PRJTPFL112-110 - inch PRJTPFL122-120 - inch Fixed Wall Mount Projector Screen Universal Home/Office Projector Viewing Display Be sure to read this manual before use so you will know

More information

MODEL HI 803 Operation and Installation Manual

MODEL HI 803 Operation and Installation Manual MODEL HI 803 Operation and Installation Manual PRINT PAPER ADV INPUT REF. 50 mv/g MODE CURSOR ABC 7 DEF 8 GHI 9 HELP SELECT RS-232 JKL 4 MNO 5 PQR 6 FREQUENCY RANGE Hz STU 1 VWX 2 YZ - 3 100 1K 10K 0 SPACE

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form

Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form MN36-268 Rev A Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form Published by Geophysical Survey Systems, Inc. 40 Simon

More information

Accredited Laboratory

Accredited Laboratory American Association for Laboratory Accreditation Accredited Laboratory A2LA has accredited PCB PIEZOTRONICS INC. Depew, NY for technical competence in the field of Calibration This laboratory is accredited

More information

4 MHz Lock-In Amplifier

4 MHz Lock-In Amplifier 4 MHz Lock-In Amplifier SR865A 4 MHz dual phase lock-in amplifier SR865A 4 MHz Lock-In Amplifier 1 mhz to 4 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric

More information

WEAVE: Web-based Educational Framework for Analysis, Visualization, and Experimentation. Steven M. Lattanzio II 1

WEAVE: Web-based Educational Framework for Analysis, Visualization, and Experimentation. Steven M. Lattanzio II 1 WEAVE: Web-based Educational Framework for Analysis, Visualization, and Experimentation Steven M. Lattanzio II 1 Abstract WEAVE (Web-Based Educational Framework for Analysis, Visualization, and Experimentation)

More information

Introduction to the oscilloscope and digital data acquisition

Introduction to the oscilloscope and digital data acquisition Introduction to the oscilloscope and digital data acquisition Eric D. Black California Institute of Technology v1.1 There are a certain number of essential tools that are so widely used that every aspiring

More information

Instructions for Vibrations Analysis

Instructions for Vibrations Analysis NanoFab www.ualberta.ca/nanofab W 1-60 ECERF Building University of Alberta Edmonton, AB T6G 2V4 Instructions for Vibrations Analysis Prepared by: Aruna Kroetch Date: November 24, 2003 Version 1.0 Table

More information

TITLE: FIBER OPTIC SHOCK FIXTURES

TITLE: FIBER OPTIC SHOCK FIXTURES ENGINEERING PRACTICE STUDY TITLE: FIBER OPTIC SHOCK FIXTURES 18 January 2007 STUDY PROJECT 60GP-2006-019 FINAL REPORT Study Conducted By Dave Leight DSCC-VAT Fiber Optic Group Prepared by: Dave Leight

More information