DAQ Systems in Hall A

Size: px
Start display at page:

Download "DAQ Systems in Hall A"

Transcription

1 CODA Users Workshop Data Acquisition at Jefferson Lab Newport News June 7, 2004 DAQ Systems in Hall A Overview of Hall A Standard Equipment: HRS, Beamline,... Parity Experiments Third Arms: BigBite, RCS Calorimeter, Neutron Array 12 GeV: MAD Summary Bodo Reitz Jefferson Lab

2 Personnel Access Tunnel 3 rd Arm Truck Ramp

3 Hall A HRS: Standard Detector Package left arm (hadron-stack) 960 Ch multihit-tdc (VDC) 128 Ch highres-tdc (trigger) 192 Ch ADC (PID) 240 Ch Scalers right arm (electron stack) 960 Ch multihit-tdc (VDC) 128 Ch highres-tdc (trigger) 256 Ch ADC (PID) 240 Ch Scalers 640 Ch multihit-tdc (FPP)

4 Standard HRS DAQ Setup typical: coincidence experiment involving both HRS event-by-event readout (plus scalers for normalization) level-one trigger: NIM/CAMAC electronics no higher level triggers, (no fast-clears) DAQ: running CODA 2.5/VXWorks 5.4 VME crate with TS (and scalers) in detector hut 2 Fastbus-crates per arm also in detector hut PCs and disk-array in counting house (RHEL)

5 Performance of the Hall A DAQ Coincidence Setup (2 HRS) single arm rates (raw): khz trigger rate after prescaling: <3 khz event size: ~1.5 kb (with pedestal suppression on) computer deadtime: 10% per 1 khz (unbuffered) Single Arm Setup both HRS run independently redistribution of Fastbus-modules avoiding slow modules (LeCroy 1875) utilizing buffered readout: 2.5% per 1 khz (up to 4 khz)

6 Issues with Present Hall A DAQ Fastbus is obsolete problems with: repairs, spares, additional channels,... switch to VME based modules but: even for VME not many commercial suppliers left rate limitations: to get reasonable deadtimes: CODA-rate <2 khz CODA issues: time-loss for downloading and rebooting after crashes time-loss for ending and starting runs (Hall A specific) only marginal help features and online-documentation within CODA strip charts of CODA are not working

7 DAQ for Beam- and Target Diagnostics polarized Helium-3 target: NMR and EPR polarimetry: PC/LabView based ARC beam energy, beam position and beam current monitors: included in EPICS environment EP beam energy, Compton and Moller Polarimeter: CODA based (various versions) single ROC in VME Crate custom made VME modules for EP and Compton (Micro-Strip detectors) usually are working fine, as long as the experts are around, and no upgrade is needed various test setups for future experiments (EEL, Test-Lab) CODA based single Crate setups (Fastbus or VME) CODA light would be helpful there will be multi-crate test-setups soon (3 rd arm experiments)

8 Hall A Parity Experiments (Happex) parity experiments requiring high statistics and therefore high rates (>1MHz) cannot be handled with the standard (event-by-event) Hall A DAQ independent DAQ system required Happex: Integrating DAQ customized ADCs (Princeton) integrating over one helicity pulse (33ms) high resolution (18 bit) high demands on linearity and noise pseudo-randomly adding of a voltage ( DAQ-noise ) to reduce non-linearity present ADC module ( Princeton ) is obsolete, JLab Electronics groups was asked to design and build a follow-up module other PV experiments: require counting based DAQ for 100 MHz rates would need customized electronics for trigger/pid decision within 10 ns

9 3 rd Arm Experiments Real Compton Scattering (experiment run in 2001) HRS(left) lead glass calorimeter with ~700 blocks (ADCs, some TDCs, some Scalers) DVCS in Hall A (scheduled for summer/fall 2004) HRS(left) proton array (100 PMTs) lead glass calorimeter with 132 blocks some customized electronics (Flash-ADCs)

10 Experiments Using a 3 rd Arm II BigBite Experiments: SRC scheduled for Jan uses both HRS BigBite spectrometer for protons, using scintillators with 152 PMTs scintillator array for neutrons ~100 bars plus ~50 veto detectors DAQ with 400 Ch. of ADCs and TDCs (VME+Fastbus)

11 Experiments Using a 3 rd Arm III Hall A GEN (end of 2005???) uses BigBite as electron arm BigBite detector package: + MWDC with ~2000 wires (multi-hit TDCs) + scintillators with 32 PMTs (high-res TDCs) + lead glass shower detector (~200 PMTs) (ADCs) uses plastic scintillators as neutron detector neutron bars (=480 Ch. high-res TDC + ADC) veto detectors (=200 Ch. multi-hit TDC + ADC)

12 3 rd Arm Experiments: demand for additional ADC+TDC (and scaler) modules significant fraction of the modules will be (has to be) in VME TDC: CAEN V767, V775, V1190, JLab-F1 ADC: CAEN V792, JLab??? frequent requests for TIR and TriggerSupervisors for help to setup CODA/DAQ systems (good documentation could reduce some of those) radiation damage 3 rd arm electronics will not be as well shielded as the ones in the HRS detector hut noticed a lot more problems with DAQ system in the RCS setup and the ones located along the beam line

13 12 GeV: MAD A totally new system, with strong requirements!

14 Comparison MAD vs HRS MAD HRS central momentum: 6.0 GeV /c 4.0 GeV/c configuration: QD QD QQDQ bend: 32 deg 45 deg mom. acceptance: +- 15% % mom. resolution: ~1E-03 1E-04 solid angle: 28 msr (6 msr) 6 msr >35deg (12deg) >12.5deg ext. target: +-6 cm +-5 cm y0 resolution: 2.6 mm (4.6mm) 1.5 mm

15 MAD: Detector Package

16 MAD: Some Specs! detector channels for MAD (MAD+1 HRS) 450(700) Ch. ADCs 200(300) Ch. TDCs (high-res., multi-hit) 1700(2700) Ch. TDCs (med-res, multi-hit) 400 Ch. scalers DAQ for MAD: rate capability has to exceed 5 khz, 20 khz desirable

17 Flash-ADCs and Pipeline-TDCs higher rate capability (>20 khz) avoids delay cables Flash-ADC: no extra TDC for that channel needed significant increase in amount of raw-data network and computer upgrades online data-reduction possibility of software second level trigger Flash-ADC: pulse form discrimination Is the necessary hardware available? pipeline-tdc: CAEN V1190 and JLab F1 first modules have been seen. experience? availability? is there a Flash-ADC in sight???

18 Summary at present: several CODA 2.x systems with VME/Fastbus issues: minor bugs, documentation near future several 3 rd arm systems under construction replacement of Fastbus which VME modules are available and recommended? 12 GeV new big detector setup, requiring higher rate capabilities upgrade of HRS DAQ necessary at the same time approach with PipelineTDC/FlashADC very desirable

Update on DAQ for 12 GeV Hall C. Brad Sawatzky

Update on DAQ for 12 GeV Hall C. Brad Sawatzky Update on DAQ for 12 GeV Hall C Brad Sawatzky SHMS/HMS Trigger/Electronics H. Fenker 2 SHMS / HMS Triggers SCIN = 3/4 hodoscope planes CER = Cerenkov(s) STOF = S1 + S2 EL-Hi = SCIN + PSh_Hi EL-Lo = 2/3{SCIN,

More information

Update on DAQ for 12 GeV Hall C

Update on DAQ for 12 GeV Hall C Update on DAQ for 12 GeV Hall C Brad Sawatzky Hall C Winter User Group Meeting Jan 20, 2017 SHMS/HMS Trigger/Electronics H. Fenker 2 SHMS / HMS Triggers SCIN = 3/4 hodoscope planes CER = Cerenkov(s) STOF

More information

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications 3 rd ADAMAS Collaboration Meeting (2014) Trento, Italy *use commercial elements and keep it small & simple + +

More information

THE UPGRADE PATH FROM LEGACY VME TO VXS DUAL STAR CONNECTIVITY FOR LARGE SCALE DATA ACQUISITION AND TRIGGER SYSTEMS

THE UPGRADE PATH FROM LEGACY VME TO VXS DUAL STAR CONNECTIVITY FOR LARGE SCALE DATA ACQUISITION AND TRIGGER SYSTEMS THE UPGRADE PATH FROM LEGACY VME TO VXS DUAL STAR CONNECTIVITY FOR LARGE SCALE DATA ACQUISITION AND TRIGGER SYSTEMS R. Chris Cuevas Group Leader Fast Electronics Experimental Nuclear Physics Division Page

More information

SVT DAQ. Per Hansson Adrian HPS Collaboration Meeting 10/27/2015

SVT DAQ. Per Hansson Adrian HPS Collaboration Meeting 10/27/2015 SVT DAQ Per Hansson Adrian HPS Collaboration Meeting 10/27/2015 Overview Trigger rate improvements Optimized data format Shorter APV25 shaping time Single event upset monitor Data integrity Plans 2 Deadtime

More information

Progress Update FDC Prototype Test Stand Development Upcoming Work

Progress Update FDC Prototype Test Stand Development Upcoming Work Progress Update FDC Prototype Test Stand Development Upcoming Work Progress Update OU GlueX postdoc position filled. Simon Taylor joins our group July 1, 2004 Position funded jointly by Ohio University

More information

Instrumentation and analysis progress for g2p experiment

Instrumentation and analysis progress for g2p experiment Instrumentation and analysis progress for g2p experiment Pengjia Zhu University of Science and Technology of China On behalf of the E08-027(g2p) collaboration 1 fifth hardon physics workshop,july th 4,2013

More information

Electronics for the HKS ENGE Hypernuclear Spectrometer System

Electronics for the HKS ENGE Hypernuclear Spectrometer System Electronics for the HKS ENGE Hypernuclear Spectrometer System Jörg Reinhold, Y. Fujii, O. Hashimoto, S.N. Nakamura, H. Nomura, T. Takahashi, L. Tang, B. Vulcan, S. Wood October 5, 2004 Abstract This document

More information

Hall-B Beamline Commissioning Plan for CLAS12

Hall-B Beamline Commissioning Plan for CLAS12 Hall-B Beamline Commissioning Plan for CLAS12 Version 1.5 S. Stepanyan December 19, 2017 1 Introduction The beamline for CLAS12 utilizes the existing Hall-B beamline setup with a few modifications and

More information

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe + + + = PaDiWa-AMPS front-end Adrian Rost for the HADES and CBM collaborations PMT Si-PM (MPPC) 27.09.2016

More information

Diamond detectors in the CMS BCM1F

Diamond detectors in the CMS BCM1F Diamond detectors in the CMS BCM1F DESY (Zeuthen) CARAT 2010 GSI, 13-15 December 2010 On behalf of the DESY BCM and CMS BRM groups 1 Outline: 1. Introduction to the CMS BRM 2. BCM1F: - Back-End Hardware

More information

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Commissioning and Initial Performance of the Belle II itop PID Subdetector Commissioning and Initial Performance of the Belle II itop PID Subdetector Gary Varner University of Hawaii TIPP 2017 Beijing Upgrading PID Performance - PID (π/κ) detectors - Inside current calorimeter

More information

G0 Laser Status Parity Controls Injector Diagnostics

G0 Laser Status Parity Controls Injector Diagnostics G0 Laser Status Parity Controls Injector Diagnostics G0 Collaboration Mtg Jefferson Lab August 16, 2002 G0 Collaboration Mtg (August 16, 2002), 1 Installed new AOM homebuilt laser G0 Collaboration Mtg

More information

Data Acquisition System for Segmented Reactor Antineutrino Detector

Data Acquisition System for Segmented Reactor Antineutrino Detector Data Acquisition System for Segmented Reactor Antineutrino Detector Z. Hons a,b,*, J. Vlášek a,c,d a Joint Institute for Nuclear Research, Moscow Region, Dubna, Russian Federation b NPI Nuclear Physics

More information

arxiv: v2 [physics.ins-det] 26 Jun 2016

arxiv: v2 [physics.ins-det] 26 Jun 2016 Beam Charge Measurement for the g2p/gep experiments Pengjia Zhu arxiv:1606.02600v2 [physics.ins-det] 26 Jun 2016 University of Science and Technology of China Abstract The g2p/gep experiments used a solid

More information

ALICE Muon Trigger upgrade

ALICE Muon Trigger upgrade ALICE Muon Trigger upgrade Context RPC Detector Status Front-End Electronics Upgrade Readout Electronics Upgrade Conclusions and Perspectives Dr Pascal Dupieux, LPC Clermont, QGPF 2013 1 Context The Muon

More information

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Test beam data analysis for the CMS CASTOR calorimeter at the LHC 1/ 24 DESY Summerstudent programme 2008 - Course review Test beam data analysis for the CMS CASTOR calorimeter at the LHC Agni Bethani a, Andrea Knue b a Technical University of Athens b Georg-August University

More information

Front End Electronics

Front End Electronics CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration

More information

Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments

Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments Status of the Jefferson Lab Polarized Beam Physics Program and Preparations for Upcoming Parity Experiments P. Adderley, M. Baylac, J. Clark, A. Day, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman PESP

More information

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC Tomas Davidek (Charles University), on behalf of the ATLAS Collaboration Tile Calorimeter Sampling

More information

GREAT 32 channel peak sensing ADC module: User Manual

GREAT 32 channel peak sensing ADC module: User Manual GREAT 32 channel peak sensing ADC module: User Manual Specification: 32 independent timestamped peak sensing, ADC channels. Input range 0 to +8V. Sliding scale correction. Peaking time greater than 1uS.

More information

Electronics Status and Upgrade Opportunities for Flash ADC and 12GeV Trigger Hardware

Electronics Status and Upgrade Opportunities for Flash ADC and 12GeV Trigger Hardware Electronics Status and Upgrade Opportunities for Flash ADC and 12GeV Trigger Hardware R. Chris Cuevas Group Leader Fast Electronics NPS Collaboration Meeting Jefferson Lab 14-November-2013 Page 1 OUTLINE

More information

Beamline improvement during g2p experiment. Pengjia Zhu

Beamline improvement during g2p experiment. Pengjia Zhu Beamline improvement during g2p experiment Pengjia Zhu Review for g2p Q2 0.02 0.20 GeV2 o 6 forward angle detection Review for g2p Polarized NH3 target 1K Refrigerator 2.5/5T Transverse target field Polarization

More information

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su Design and prototype tests of the system for the OPERA spectrometers Stefano Dusini INFN sezione di Padova Outline OPERA Detector Inner Tracker Design Mechanical support Gas & HV Production and Quality

More information

SciFi A Large Scintillating Fibre Tracker for LHCb

SciFi A Large Scintillating Fibre Tracker for LHCb SciFi A Large Scintillating Fibre Tracker for LHCb Roman Greim on behalf of the LHCb-SciFi-Collaboration 14th Topical Seminar on Innovative Particle Radiation Detectors, Siena 5th October 2016 I. Physikalisches

More information

A new Scintillating Fibre Tracker for LHCb experiment

A new Scintillating Fibre Tracker for LHCb experiment A new Scintillating Fibre Tracker for LHCb experiment Alexander Malinin, NRC Kurchatov Institute on behalf of the LHCb-SciFi-Collaboration Instrumentation for Colliding Beam Physics BINP, Novosibirsk,

More information

Beam test of the QMB6 calibration board and HBU0 prototype

Beam test of the QMB6 calibration board and HBU0 prototype Beam test of the QMB6 calibration board and HBU0 prototype J. Cvach 1, J. Kvasnička 1,2, I. Polák 1, J. Zálešák 1 May 23, 2011 Abstract We report about the performance of the HBU0 board and the optical

More information

HPS Slow Controls Overview

HPS Slow Controls Overview HPS Slow Controls Overview Hovanes Egiyan 6/18/2014 Hovanes Egiyan HPS Collaboration Meeting 1 Content Introduction HPS SVT Controls ECAL Controls Hall B controls Summary 6/18/2014 Hovanes Egiyan HPS Collaboration

More information

Miniball electronics for Orsay

Miniball electronics for Orsay Miball electronics for Orsay Nigel Warr and Iolanda Matea 1 st June 2014 1 Contents 1 Foreword 3 2 Overview 3 3 The DGF BUSY/SYNCH loop 4 4 The GFLT fan- 5 5 The DAQ dead and DAQ go 6 6 Generation of the

More information

An extreme high resolution Timing Counter for the MEG Upgrade

An extreme high resolution Timing Counter for the MEG Upgrade An extreme high resolution Timing Counter for the MEG Upgrade M. De Gerone INFN Genova on behalf of the MEG collaboration 13th Topical Seminar on Innovative Particle and Radiation Detectors Siena, Oct.

More information

Kmax-based Event Mode Data Acquisition System for the University of Kentucky Accelerator Laboratory

Kmax-based Event Mode Data Acquisition System for the University of Kentucky Accelerator Laboratory Kmax-based Event Mode Data Acquisition System for the University of Kentucky Accelerator Laboratory Benjamin P. Crider Department of Physics and Astronomy, University of Kentucky, Lexington, KY 40506-0055

More information

Tracking Detector R&D at Cornell University and Purdue University

Tracking Detector R&D at Cornell University and Purdue University Tracking Detector R&D at Cornell University and Purdue University We have requested funding for this research from NSF through UCLC. Information available at the web site: * this presentation Cornell University

More information

HAPD and Electronics Updates

HAPD and Electronics Updates S. Nishida KEK 3rd Open Meeting for Belle II Collaboration 1 Contents Frontend Electronics Neutron Irradiation News from Hamamtsu 2 144ch HAPD HAPD (Hybrid Avalanche Photo Detector) photon bi alkali photocathode

More information

TORCH a large-area detector for high resolution time-of-flight

TORCH a large-area detector for high resolution time-of-flight TORCH a large-area detector for high resolution time-of-flight Roger Forty (CERN) on behalf of the TORCH collaboration 1. TORCH concept 2. Application in LHCb 3. R&D project 4. Test-beam studies TIPP 2017,

More information

CSC Data Rates, Formats and Calibration Methods

CSC Data Rates, Formats and Calibration Methods CSC Data Rates, Formats and Calibration Methods D. Acosta University of Florida With most information collected from the The Ohio State University PRS March Milestones 1. Determination of calibration methods

More information

An Operational Diagnostic Complement for Positrons at CEBAF/JLab

An Operational Diagnostic Complement for Positrons at CEBAF/JLab An Operational Diagnostic Complement for Positrons at CEBAF/JLab Michael Tiefenback JLab, CASA International Workshop on Physics with Positrons at Jefferson Lab 12-15 September 2017 Operating CEBAF with

More information

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector William Nalti, Ken Suzuki, Stefan-Meyer-Institut, ÖAW on behalf of the PANDA/Barrel-TOF(SciTil) group 12.06.2018, ICASiPM2018 1

More information

Rome group activity since last meeting (4)

Rome group activity since last meeting (4) OLYMPUS Collaboration DESY 30/August/2010 Rome group activity since last meeting (4) DESY 30/August/2010 Olympus Collaboration meeting Salvatore Frullani / INFN-Rome Sanità Group 1 GEM electronics: Outline

More information

In-process inspection: Inspector technology and concept

In-process inspection: Inspector technology and concept Inspector In-process inspection: Inspector technology and concept Need to inspect a part during production or the final result? The Inspector system provides a quick and efficient method to interface a

More information

Outline. GEM R&D and assembly facilities at UVa. Cosmic test results. Update on the cm 2 GEM prototype

Outline. GEM R&D and assembly facilities at UVa. Cosmic test results. Update on the cm 2 GEM prototype Uva GEM R&D Update Kondo Gnanvo, Nilanga Liyanage, Vladimir Nelyubin, Kiadtisak Saenboonruang, Taylor Scholz and Adarsh Ramakrishnan In Collaboration with Evaristo Cisbani and Paolo Musico Outline GEM

More information

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out P.Branchini, F.Ceradini, B.Di Micco, A. Passeri INFN Roma Tre and Dipartimento di Fisica Università Roma Tre and

More information

Parity Quality Beam (PQB) Study

Parity Quality Beam (PQB) Study Parity Quality Beam (PQB) Study Injector Group November 10, 2008 Thanks to: Roger Flood, Pete Francis, Paul King, Bob Michaels, Julie Roche Notes: 1. For each BPM, the wires are: +X+, +X-, +Y+, +Y-. 2.

More information

The CALICE test beam programme

The CALICE test beam programme Journal of Physics: Conference Series The CALICE test beam programme To cite this article: F Salvatore 2009 J. Phys.: Conf. Ser. 160 012064 View the article online for updates and enhancements. Related

More information

Front End Electronics

Front End Electronics CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration

More information

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL* I... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL* R. G. Friday and K. D. Mauro Stanford Linear Accelerator Center Stanford University, Stanford, California 94305 SLAC-PUB-995

More information

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

An Overview of Beam Diagnostic and Control Systems for AREAL Linac An Overview of Beam Diagnostic and Control Systems for AREAL Linac Presenter G. Amatuni Ultrafast Beams and Applications 04-07 July 2017, CANDLE, Armenia Contents: 1. Current status of existing diagnostic

More information

BABAR IFR TDC Board (ITB): requirements and system description

BABAR IFR TDC Board (ITB): requirements and system description BABAR IFR TDC Board (ITB): requirements and system description Version 1.1 November 1997 G. Crosetti, S. Minutoli, E. Robutti I.N.F.N. Genova 1. Timing measurement with the IFR Accurate track reconstruction

More information

arxiv: v1 [physics.ins-det] 1 Nov 2015

arxiv: v1 [physics.ins-det] 1 Nov 2015 DPF2015-288 November 3, 2015 The CMS Beam Halo Monitor Detector System arxiv:1511.00264v1 [physics.ins-det] 1 Nov 2015 Kelly Stifter On behalf of the CMS collaboration University of Minnesota, Minneapolis,

More information

Paul Rubinov Fermilab Front End Electronics. May 2006 Perugia, Italy

Paul Rubinov Fermilab Front End Electronics. May 2006 Perugia, Italy Minerva Electronics and the Trip-T Paul Rubinov Fermilab Front End Electronics May 2006 Perugia, Italy 1 Outline Minerva Electronics and the TriP-t Minerva TriP-t The concept for Minerva Overview and status

More information

Novel Data Acquisition System for Silicon Tracking Detectors

Novel Data Acquisition System for Silicon Tracking Detectors Novel Data Acquisition System for Silicon Tracking Detectors L. A. Wendland, K. Banzuzi, S. Czellar, A. Heikkinen, J. Härkönen, P. Johansson, V. Karimäki, T. Lampén, P. Luukka, P. Mehtälä, J. Niku, S.

More information

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors Atlas Pixel Replacement/Upgrade and Measurements on 3D sensors Forskerskole 2007 by E. Bolle erlend.bolle@fys.uio.no Outline Sensors for Atlas pixel b-layer replacement/upgrade UiO activities CERN 3D test

More information

Polarized Source Development Run Results

Polarized Source Development Run Results Polarized Source Development Run Results Riad Suleiman Injector Group November 18, 2008 Outline Injector Parity DAQ and Helicity Board Pockels Cell Alignment Fast Helicity Reversal Studies: o 30 Hz, 250

More information

Development at Jefferson Lab

Development at Jefferson Lab JLABACC9727 5 MeV Mott Polarimeter Development at Jefferson Lab J.S. Price* B.M. Poelker* C.K. Sinclair* K.A. Assamagant L.S. Cardman* J. Gramest J. Hansknecht* D.J. Mack* and P. Piot* *Jefferson Lab 1.2000

More information

Development of BPM Electronics at the JLAB FEL

Development of BPM Electronics at the JLAB FEL Development of BPM Electronics at the JLAB FEL D. Sexton, P. Evtushenko, K. Jordan, J. Yan, S. Dutton, W. Moore, R. Evans, J. Coleman Thomas Jefferson National Accelerator Facility, Free Electron Laser

More information

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds Juan Palacios, On behalf of the LHCb VELO group J.P. Palacios, Liverpool Outline LHCb and VELO performance

More information

Glast beam test at CERN

Glast beam test at CERN Glast beam test at CERN Glast Collaboration Meeting 2005 R. Bellazzini 1 LAT beam test at CERN Main goals LAT-TD-02152, see Steve slides Required beam types and related measurements 1. tagged-photon beam

More information

PMT Gain & Resolution Measurements in High Magnetic Fields

PMT Gain & Resolution Measurements in High Magnetic Fields PMT Gain & Resolution Measurements in High Magnetic Fields Vincent Sulkosky University of Virginia August 11 th, 2015 SoLID EC Meeting High-B Sensor-Testing Facility 2 The facility was designed for the

More information

Eric Oberla Univ. of Chicago 15-Dec 2015

Eric Oberla Univ. of Chicago 15-Dec 2015 PSEC4 PSEC4a Eric Oberla Univ. of Chicago 15-Dec 2015 PSEC4 ---> PSEC4a :: overview PSEC4a 6 2-11 GSa/s 256 1024 (or 2048?) 100 (or 200) ns continuous OR 4x (or 8x) 25 ns snapshots [Multi-hit buffering]

More information

Status of the Timing Detector Plastic+SiPM Readout Option

Status of the Timing Detector Plastic+SiPM Readout Option SHiP Timing Detector Status of the Timing Detector Plastic+SiPM Readout Option Ruth Bruendler, University of Zurich on behalf of the Timing Detector Group 11th SHIP Collaboration Meeting CERN 7-9 June

More information

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov Part 1: The TBM and CMS Understanding how the LHC and the CMS detector work as a

More information

FMS Update: Spin PWG. Stephen Trentalange April

FMS Update: Spin PWG. Stephen Trentalange April FMS Update: Spin PWG Stephen Trentalange April 16 2015 Summary of FMS Operations FMS is performing well and is fairly stable. No sign this year of runaway trigger Solved problem with Lecroy Voltage instabilities

More information

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park Overview We have developed a system for measuring and scanning phototubes for the FDIRC Based primarily on

More information

Preliminary Conclusions from Recent Q weak Target Density Fluctuation Studies Mark Pitt, Virginia Tech

Preliminary Conclusions from Recent Q weak Target Density Fluctuation Studies Mark Pitt, Virginia Tech Preliminary Conclusions from Recent Q weak Target Density Fluctuation Studies Mark Pitt, Virginia Tech Brief report on results of the Qweak June 008 luminosity monitor studies of the dependence of target

More information

The TRIGGER/CLOCK/SYNC Distribution for TJNAF 12 GeV Upgrade Experiments

The TRIGGER/CLOCK/SYNC Distribution for TJNAF 12 GeV Upgrade Experiments 1 1 1 1 1 1 1 1 0 1 0 The TRIGGER/CLOCK/SYNC Distribution for TJNAF 1 GeV Upgrade Experiments William GU, et al. DAQ group and Fast Electronics group Thomas Jefferson National Accelerator Facility (TJNAF),

More information

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade Yuri Musienko* FNAL(USA) Arjan Heering University of Notre Dame (USA) For the CMS HCAL group *On leave from INR(Moscow)

More information

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD D. LO PRESTI D. BONANNO, F. LONGHITANO, D. BONGIOVANNI, S. REITO INFN- SEZIONE DI CATANIA D. Lo Presti, NUMEN2015 LNS, 1-2 December 2015 1 OVERVIEW

More information

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010 MCP Signal Extraction and Timing Studies Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010 Outline Studying algorithms to process pulses from MCP devices. With the goal of

More information

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015 Report from the 2015 AHCAL beam test at the SPS Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015 Goals and Preparation > first SPS test beam with 2nd generation electronics and DAQ

More information

Hall A Simulation & Analysis

Hall A Simulation & Analysis Hall A Simulation & Analysis Ole Hansen Jefferson Lab IT for the 12 GeV Era Internal Review May 20, 2011 Ole Hansen (Jefferson Lab) Hall A Simulation & Analysis May 20, 2011 1 / 9 Hall A 12 GeV Experiments

More information

New Spill Structure Analysis Tools for the VME Based Data Acquisition System ABLASS at GSI

New Spill Structure Analysis Tools for the VME Based Data Acquisition System ABLASS at GSI New Spill Structure Analysis Tools for the VME Based Data Acquisition System ABLASS at GSI T. Hoffmann, P. Forck, D. A. Liakin * Gesellschaft f. Schwerionenforschung, Planckstr. 1, D-64291 Darmstadt *

More information

Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager

Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager HWDB: Operations at the Spallation Neutron Source Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager Outline Facility overview Organization Shift schedule

More information

Sensors for the CMS High Granularity Calorimeter

Sensors for the CMS High Granularity Calorimeter Sensors for the CMS High Granularity Calorimeter Andreas Alexander Maier (CERN) on behalf of the CMS Collaboration Wed, March 1, 2017 The CMS HGCAL project ECAL Answer to HL-LHC challenges: Pile-up: up

More information

LHCb and its electronics. J. Christiansen On behalf of the LHCb collaboration

LHCb and its electronics. J. Christiansen On behalf of the LHCb collaboration LHCb and its electronics J. Christiansen On behalf of the LHCb collaboration Physics background CP violation necessary to explain matter dominance B hadron decays good candidate to study CP violation B

More information

ECAL LED system update. A. Celentano

ECAL LED system update. A. Celentano ECAL LED system update A. Celentano 1 ECAL LMS overview (x 4) Design: individual bi-color LEDs mounted in front of each PbWO4 crystal. Main controllers (2 x) Driver Boards (8 x) Connection boards (4 x)

More information

HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC

HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC S. Callier a, F. Dulucq a, C. de La Taille a, G. Martin-Chassard a, N. Seguin-Moreau a a OMEGA/LAL/IN2P3, LAL Université Paris-Sud, Orsay,France

More information

Study of the performances of the ALICE muon spectrometer

Study of the performances of the ALICE muon spectrometer Study of the performances of the ALICE muon spectrometer Blanc Aurélien, December 2008 PhD description Study of the performances of the ALICE muon spectrometer instrumentation/detection. Master Physique

More information

Local Trigger Electronics for the CMS Drift Tubes Muon Detector

Local Trigger Electronics for the CMS Drift Tubes Muon Detector Amsterdam, 1 October 2003 Local Trigger Electronics for the CMS Drift Tubes Muon Detector Presented by R.Travaglini INFN-Bologna Italy CMS Drift Tubes Muon Detector CMS Barrel: 5 wheels Wheel : Azimuthal

More information

The trigger for the New Electromagnetic Calorimeter NewCal

The trigger for the New Electromagnetic Calorimeter NewCal The trigger for the New Electromagnetic Calorimeter NewCal Feasibility studies (2d version) Charles F. Perdrisat June 21,2012 6/20/2012 1 Assumptions: HERA-B midsection shashlik detectors available, 2128

More information

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi) Commissioning of Accelerators Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi) www.europeanspallationsource.se 6 July, 2017 Contents General points Definition of Commissioning

More information

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766: TitleLarge strip RPCs for the LEPS2 TOF Author(s) Tomida, N.; Niiyama, M.; Ohnishi, H Chu, M.-L.; Chang, W.-C.; Chen, J.- Nuclear Instruments and Methods in Citation A: Accelerators, Spectrometers, Det

More information

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE Stefan Ritt, Paul Scherrer Institute, Switzerland Luca Galli, Fabio Morsani, Donato Nicolò, INFN Pisa, Italy THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE DRS4 Chip 0.2-2 ns Inverter Domino ring chain IN Clock

More information

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update Tom Browder, Herbert Hoedlmoser, Bryce Jacobsen, Jim Kennedy, KurtisNishimura, Marc Rosen, Larry Ruckman, Gary Varner Kurtis Nishimura SuperKEKB

More information

with Low Cost and Low Material Budget

with Low Cost and Low Material Budget Gaseous Beam Position Detectors, with Low Cost and Low Material Budget Gyula Bencédi on behalf of the REGaRD group MTA KFKI RMKI, ELTE November 29, 2011, Outline Physics Motivation Newish MWPCs, the Close

More information

Paul Dauncey For the CALICE-UK electronics group. A. Baird, D. Bowerman, P. Dauncey, R. Halsall, M. Postranecky, M.Warren, O.

Paul Dauncey For the CALICE-UK electronics group. A. Baird, D. Bowerman, P. Dauncey, R. Halsall, M. Postranecky, M.Warren, O. ECAL Readout Paul Dauncey For the CALICE-UK electronics group A. Baird, D. Bowerman, P. Dauncey, R. Halsall, M. Postranecky, M.Warren, O. Zorba 8 December 2004 Paul Dauncey 1 CALICE Readout (ECAL) Card

More information

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

Jefferson Lab Experience with Beam Halo, Beam Loss, etc. Jefferson Lab Experience with Beam Halo, Beam Loss, etc. Pavel Evtushenko with a lot of input from many experienced colleagues Steve Benson, Dave Douglas, Kevin Jordan, Carlos Hernandez-Garcia, Dan Sexton,

More information

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01 100KSPS 16-bit Analog Unit for USB AI-1664LAX-USB * Specifications, color and design of the products are subject to change without notice. This product is a USB2.0-compliant analog input unit that extends

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

High ResolutionCross Strip Anodes for Photon Counting detectors

High ResolutionCross Strip Anodes for Photon Counting detectors High ResolutionCross Strip Anodes for Photon Counting detectors Oswald H.W. Siegmund, Anton S. Tremsin, Robert Abiad, J. Hull and John V. Vallerga Space Sciences Laboratory University of California Berkeley,

More information

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals M. Ippolitov 1 NRC Kurchatov Institute and NRNU MEPhI Kurchatov sq.1, 123182, Moscow, Russian Federation E-mail:

More information

Klystron Lifetime Management System

Klystron Lifetime Management System Klystron Lifetime Management System Łukasz Butkowski Vladimir Vogel FLASH Seminar Outline 2 Introduction to KLM Protection and measurement functions Installation at Klystron test stand FPGA implementation

More information

LHC Beam Instrumentation Further Discussion

LHC Beam Instrumentation Further Discussion LHC Beam Instrumentation Further Discussion LHC Machine Advisory Committee 9 th December 2005 Rhodri Jones (CERN AB/BDI) Possible Discussion Topics Open Questions Tune measurement base band tune & 50Hz

More information

Large Area, High Speed Photo-detectors Readout

Large Area, High Speed Photo-detectors Readout Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun Tang +, Gary Varner ++, and Henry Frisch + + University

More information

BEMC electronics operation

BEMC electronics operation Appendix A BEMC electronics operation The tower phototubes are powered by CockroftWalton (CW) bases that are able to keep the high voltage up to a high precision. The bases are programmed through the serial

More information

1 Digital BPM Systems for Hadron Accelerators

1 Digital BPM Systems for Hadron Accelerators Digital BPM Systems for Hadron Accelerators Proton Synchrotron 26 GeV 200 m diameter 40 ES BPMs Built in 1959 Booster TT70 East hall CB Trajectory measurement: System architecture Inputs Principles of

More information

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA Tsutomu Nagayoshi for the CTA-Japan Consortium Saitama Univ, Max-Planck-Institute for Physics 1 Cherenkov Telescope

More information

A TARGET-based camera for CTA

A TARGET-based camera for CTA A TARGET-based camera for CTA TeV Array Readout with GSa/s sampling and Event Trigger (TARGET) chip: overview Custom-designed ASIC for CTA, developed in collaboration with Gary Varner (U Hawaii) Implementation:

More information

Performance of the MCP-PMT for the Belle II TOP counter

Performance of the MCP-PMT for the Belle II TOP counter Performance of the MCP-PMT for the Belle II TOP counter Kodai Matsuoka (KMI, Nagoya Univ.) S. Hirose, T. Iijima, K. Inami, Y. Kato, Y. Maeda, R. Mizuno, Y. Sato, K. Suzuki (Nagoya Univ.) TOP (Time Of Propagation)

More information

Online Monitoring of L1CT in Run IIa. bonus: experience from Run I

Online Monitoring of L1CT in Run IIa. bonus: experience from Run I Online Monitoring of L1CT in Run IIa bonus: experience from Run I Philippe Laurens 20-Feb-2003 L1 Cal Monitoring Monitoring can mean many things Anything related to observation of system s operation Different

More information

SuperB- DCH. Servizio Ele<ronico Laboratori FrascaA

SuperB- DCH. Servizio Ele<ronico Laboratori FrascaA 1 Outline 2 DCH FEE Constraints/Estimate & Main Blocks front- end main blocks Constraints & EsAmate Trigger rate (150 khz) Trigger/DAQ data format I/O BW Trigger Latency Minimum trigger spacing. Chamber

More information

First Simultaneous Top-up Operation of Three Different Rings in KEK Injector Linac

First Simultaneous Top-up Operation of Three Different Rings in KEK Injector Linac First Simultaneous Top-up Operation of Three Different Rings in KEK Injector Linac Masanori Satoh (Acc. Lab., KEK) for the injector upgrade group 2010/9/16 1 Overview of Linac Beam Operation 2010/9/16

More information