CAEN Tools for Discovery

Size: px
Start display at page:

Download "CAEN Tools for Discovery"

Transcription

1 Tools for Discovery n Rev November 2011 GD2473 SiPM Development Kit QuickStart Guide Rev March 2014

2 Purpose of this Guide This QuickStart Guide contains basic information and examples that will let you use SIPM educational Kit in few steps. Change Document Record Date Revision Changes May Initial release. July n.a. November Revised all chapters; new document format May Revised Software Installation in chapter 2 December Revised chapters 1 and 2 March Revised LabVIEW requirements in Tab. 2.1 Symbols, abbreviated terms and notation AMC FPGA DPP FPGA OS PSAU ROC FPGA SiPM Reference Documents DT5720 User Manual Acquisition & Memory Controller FPGA Digital Pulse Processing Field Programmable Gate Array Operating System Power Supply & Amplification Unit ReadOut Controller FGPA Silicon Photo-Multiplier UM1935 CAENDigitizer User & Reference Manual GD First Installation Guide to Desktop Digitizers & MCA CAEN S.pA. Via Vetraia, Viareggio (LU) - ITALY Tel Fax info@caen.it CAEN SpA 2014 Disclaimer No part of this manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of CAEN SpA. The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. CAEN SpA reserves the right to modify its products specifications without giving any notice; for up to date information please visit

3 SiPM Development Kit QuickStart Guide

4 2473 SiPM Development Kit QuickStart Guide 4

5 1 System Overview The SiPM Kit is a modular set-up based on Silicon Photo-Multipliers, the state-of-the-art sensors for low light detection with photon number resolving capabilities. The full kit, called Educational, comprises (a simplified kit, called Evaluation, is also available): Nr. 1 Power Supply & Amplification Unit (PSAU, ID code SP5600). The PSAU supplies the bias for the sensors, features a variable amplification factor up to 50 db and integrates a feedback circuit to stabilize the sensor gain against temperature variations. Moreover, the PSAU includes one leading edge discriminator/channel and a coincidence circuit for flexible event trigger logic. Sensors housed in dedicated mechanical holders can be directly connected to the PSAU. The PSAU technical specifications are reported in the relevant data sheet, together with the front and rear panel description. SiPM Holders, each one housing an Hamamatsu MPPC 1x1 mm2 model S C. The mechanical structure of the holders allows an easy coupling of the holders themselves with the PSAU. Nr. 1 Desktop Waveform digitizer (ID code DT5720A), with 2 input channels sampled at 250 MS/s by a 12 bit ADC. The DT5720A runs the Digital Pulse Processing for enhanced triggering and integration capabilities. The Digitizer technical specifications are reported in the relevant User s manual, together with the front and rear panel description. Nr. 1 ultra-fast LED Driver (ID code SP5601) with pulse width at ns level, tunable intensity, pulsing frequency internally/externally generated and FC interface to either a clear or a Wave Length Shifting (WLS) fiber. The LED unit was designed to provide a low-cost tool for the SiPM characterization and its technical specifications are reported in the relevant data sheet, together with the front and rear panel description. Nr. 1 plastic scintillating tile (ID code SP5602). Scintillation light is collected by a WLS fibre, FC terminated at its tips and ready-to-mount on the PSAU. The tile, with a sensitive volume of 100 x 100 x 10 mm3, provides an easy-to-use access to beta emitting isotope and cosmic ray detection. Its technical specifications will be reported in the coming soon data sheet. Nr. 1 mini-spectrometer for gamma ray detection (ID code SP5603), engineered as special holder to be directly mounted on the PSAU. Two different heads are provided, housing a series of crystals, including a CsI one, bound to be interfaced to a sensor matrix. The spectrometer heads were designed to make easy a full range of basic gamma spectrometry educational experiments. The main features of the spectrometer heads in will be reported in the coming soon data sheet. External AC/DC stabilized 12V power supplies (Meanwell GS40A12-P1J 40W, 12V DC Output, 3.34A). USB cables, Optical Fibres and Power cords A LabView based Graphical Users Interface The different building blocks of the kit can be assembled in a customized configuration, according to the specific application and the user s requirements. The scope of this guide is to provide a hands-on primer on the use of the essential functionalities of the kit SiPM Development Kit QuickStart Guide

6 Item description Code Image Education al kit Evaluation kit SP Channels General Purpose Amplifier and Power Supply WSP5600XAAAA yes yes DT5720A - 2 Ch. 12 bit 250 MS/s WDT5720AXAAA yes yes SP Led Driver WSP5601XAAAA yes Yes SP Scintillating Tile WSP5602XAAAA yes No SP Mini Spectrometer WSP5603XAAAA yes no Tab. 1.1: Building blocks of the kit 2473 SiPM Development Kit QuickStart Guide 6

7 2 Getting started This chapter will guide you through the installation of the Graphical Users Interface (GUI) and the first measurements based on the use of the PSAU. Software Installation Minimum system requirements: Windows XP/Vista/7 (32/64-bit) OS Hardware CAEN drivers required Third-party software required Tab. 2.1: host PC requirements 2 available USB2.0 ports DT5720 USB driver (32/64- bit) SP5600 USB driver (32/64- bit) LabView Run-Time Engine 2009 SP1 - (32-bit Standard RTE) available free of charge at the NI website. You need to download the USB drivers for both DT5720 and SP5600 compliant to your Windows version (32 or 64-bit) and the LabView based Control Software (a single package compliant to 32 and 64-bit Windows OSs). To do this, go to the SP5600A KIT webpage and click on the Software/Firmware section: Install the DT5720 drivers following the instruction of the setup wizard. When you connect DT5720 to your PC the OS will recognize it automatically. If the automatic installation fails, perform it manually from the Device Manager by selecting the driver update and pointing to the driver folder you downloaded from CAEN website. Refer to [RD3] for detailed installation OSdependent. Connect SP5600 to your PC; it will recognize as a new peripheral by the OS. Please select as driver the one you downloaded from CAEN website. Finally, a COMM port will be associated to SP5600; please check the port number. For Windows XP you can do it going to Control Panel -> System -> Hardware tab -> Device Manager (as shown in Fig. 2.1) Fig. 2.1: Tracking the PSAU port assignment on a PC running Windows XP SiPM Development Kit QuickStart Guide

8 Unzip the SiPM kit Control Software; it doesn t require an installation, a double click on the.exe file will make it work. Important Note: Releases of the SiPM Kit Control Software 0.6-build strictly need a digitizer USB Driver release if running in a 32-bit Windows environment. GUI main panel The GUI main panel is structured as a virtual instrument : its appearance and operations imitate a real central system (Fig. 2.2). Three sub-panels may be identified: Upper-left panel: tabs refer to the Digitizer PSAU SP5600 Bottom-left panel: tabs address the DT5720 Right-hand side panel: visualization of the measurements and data storage. The bottom-right side of the GUI allows the user to retrieve or save a configuration file with all the set parameters for the digitizer and the PSAU, to save the current visualized data on the visualization tabs and the plots in the active tab as image files. Fig. 2.2: GUI main panel 2473 SiPM Development Kit QuickStart Guide 8

9 The DIGITIZER tab In the digitizer tab is possible to set all the parameters requested by the digitizer: the active channel, the input DC offset, the channel threshold, the trigger mode, the trigger, the gate and the baseline parameters and the settings for the coincidence. The tab include also information about connection and errors. Acquisition settings sub tab: Fig. 2.3: Acquisition settings sub tab START DIGITIZER: the digitizer tab is inactive till the digitizer is on. Pushing the START DIGITIZER button the software create a link with the physical device. After the green light the parameters tab become active. CHANNEL ON/OFF: the channels involved in the data readout of the digitizer. When one channel is active, the correspondent input DC offset and threshold controls are enabled. INPUT DC OFFSET: it is a percentage shift of the input range scale (=2 Vpp), allowing the dynamic range to be shifted from - 2.0/0 V up to 0/2.0 V. -50% is its minimum value and it corresponds to -2.0/0 V dynamic range. 0% corresponds to a - 1.0/+1.0 V dynamic range. The control is enabled when the correspondent channel is active. CHANNEL THRESHOLD: it represents the threshold over delta, allowing the detection of the pulses, in auto-trigger mode. The delta is the difference between the current sample, i.e. the input signal sampled at time t, and the average of a samples digitized rise time ns before t. The control is enabled when the correspondent channel is active. TRIGGER MODE: if internal trigger mode is selected, the digitizer is able to self-detect the signals, according to the trigger parameters. If external trigger mode is selected, the digitizer wait a trigger signal on the LEMO TRG IN connector on the front panel SiPM Development Kit QuickStart Guide

10 TRIGGER PARAMETERS: Before the calculation of the delta, the input signal is filtered in order to reduce the high frequency noise, using a low pass filter that averages a certain number of samples within a moving window. mean represents the number of double sampling periods used by the average window; allowed values for the parameter are 1, 2, 4, 8, 16 and 32. RISE TIME is the rise time of the input signal, used in the calculation of the signal delta. GATE PARAMETERS: gate represents: The width of the gate signals, if FIXED GATE MODE is selected: The width of the gate between the input signal under threshold crossing and the end of the gate, if MATCHED GATE MODE is selected; pre gate is the advance between the gate generation and the trigger leading edge. hold-off is a veto for the generation of other gates. BASELINE PARAMETERS: the threshold represents the value on delta, over that the baseline calculation is frozen. The mean parameter is the number of samples for the average calculation of the baseline. 0 disables the baseline restoration. no flat is the veto for the calculation of baseline. COINCIDENCE PARAMETERS: the coincidence can be selected if both the channels are switched on. Coincidence time represents the width of the discriminator signal of each channel. Two signals are in coincidence if all of them exceed their own threshold during this time width SiPM Development Kit QuickStart Guide 10

11 Connection & errors sub tab: Fig. 2.4: Connection & errors sub tab CONNECTION HANDLE: once the device is opened, the function returns a handle that becomes the unique identifier of that device; any access operation to the device will take place according to its handle, thus making transparent the physical channel. ROC & AMC FIRMWARE RELEASE: these fields contain the current firmware release running on the mainboard (i.e. on the ROC FPGA) and on the mezzanine (i.e. on the AMC PFGA). ERROR OUT: any error given back by the CAENDigitizer library which the program stands on, is reported in the field code. Please, refer to [RD2] for the return codes table SiPM Development Kit QuickStart Guide

12 The PSAU tabs The PSAU tabs allow the user to set and monitor all the PSAU parameters. They become active after the communication with the PSAU is started, through the START PSAU button. This button opens the communication with the PSAU by the selected COMM Port. Important Note: if you wish to set and monitor all the PSAU parameters in Standalone mode, you shall use the PSAU Control Software: unzip the PSAU Control Software; it doesn t require an installation, a double click on the.exe file will make it work; only the PSAU tabs of SiPM kit Control Software will be displayed.). The Bias/Gain tab provides the switchers for the two channels enabling the settings of the bias, the gain and the temperature compensation. The Bias/Gain tab provides the switchers for the two channels enabling the settings of the bias, the gain and the temperature compensation. The T monitor tab shows the temperature of the two SiPM and the temperature of the board SiPM Development Kit QuickStart Guide 12

13 The Discriminator tab allows the settings of the threshold of the discriminators and the width of the signal produced as output. The output level can be set as NIM or TTL. The coincidence is active if the two PSAU channels are switched on. The coincidence signal is provided on the digital output 0 (DOUT 0) The T compensation allows the setting of the coefficient dv/dt for both the channels. The compensation acts on the bias of the sensor to keep its gain constant, according to a linear VT dependence. The Errors tab contains the PSAU firmware release and the error code of the library which the PSAU stands on and reported in Tab SiPM Development Kit QuickStart Guide

14 Error code Value Meaning PSAU_Success 0 Operation completed successfully PSAU_InvalidComPortError -1 Error related to the COM port PSAU_TooManyClientsError -2 Max. nr. of PSAUs simultaneously manageable exceeded. PSAU_CommunicationError -3 Communication error PSAU_InvalidHandleError -4 Invalid device handler PSAU_InvalidHandleError -5 Unspecified error PSAU_InvalidCommandError -6 Invalid command error PSAU_InvalidParameterError -7 Invalid parameter error PSAU_DeviceNotFound -8 Device error (e.g. hardware or firmware issue) Tab. 2.2: PSAU library return codes 2473 SiPM Development Kit QuickStart Guide 14

15 The visualization tabs The visualization tabs allow the user to manage and visualize the signals of the SiPMs. The Histogram, charge vs time, wave and 2 channel Histograms tabs refer to the digitizer. The other two, PSAU Staircase and PSAU counting, refer to the PSAU. The Histogram tab shows the histogram of the active channel according to the PSAU and digitizer settings. The user can change the refresh rate in the meaning of the access to the buffer of the digitizer: high refresh rate means high access rate to the digitizer and low number of integral signals transferred; low refresh rate means low access rate to the digitizer, but a big amount of data transferred for each access. The properties of the X scale of the histogram can be selected by the user: the origin of the histogram (in the meaning of the minimum plotted charge value), the number of bins (which determine the end of the plotting window) and the bin size. These values determine the range of the histogram that will be stored pushing the SAVE button. The prefix of the histogram output file saved can be written by the user in the Histo file name field. Fig. 2.5: Histogram tab The graph palette of the histogram allows the user to change the visualization of the spectrum, i.e. enlarging the histogram, zooming it, etc SiPM Development Kit QuickStart Guide

16 The charge vs time tab plots the charge versus time. The user can zoom in and zoom out the plot, and change the number of charges for the plotted mean. Fig. 2.6: charge vs time tab 2473 SiPM Development Kit QuickStart Guide 16

17 The wave tab shows the trace of the analog and digital signals read from the digitizer. The analog signals are the trace of the input and the virtual probe, which, in internal trigger mode, can be the delta or the baseline signal. If external trigger mode is selected, the virtual probe automatically switches on baseline only. The digital signals are the Gate (red), the Time Over Threshold (yellow), the Holdoff time (blu), the Flat signal i.e. the signal that visualize the baseline calculation (violet): the gate, flat and over threshold signals represent the digitizer selected parameters; the over threshold is generated when the signal is over the set threshold; All the trace can be amplified with the Scale control and moved in vertical position with the Position control. The switch on the bottom-left side of the tab changes the plotting mode from a continuous stream of data to single shot. In single shot mode the update of the plot stops, and the user has to push SHOT button for visualize another triggered signal. Fig. 2.7: Wave tab SiPM Development Kit QuickStart Guide

18 The 2 channel Histograms tab allows for managing the histogram plots from the two channels of the digitizer simultaneously. In the three sub tabs it is possible to plot, reset and save the two histograms, the histogram sum and the correlation. The Histos sub tab contains two histogram plots, where it is possible to set the x-axis origin, the number of bins and the bin size in a dedicated menu common to both the channels, the reset histograms button and the saving menu (output file prefix, common to both the files, and the SAVE button to perform the saving) Fig. 2.8: Histos sub tab of 2 channel Histogram main tab 2473 SiPM Development Kit QuickStart Guide 18

19 The Histo Sum sub tab contains the plot of the histogram sum. This histogram results from adding channel0 s histogram to channel1 s histogram multiplied by an alpha factor. Fig. 2.9: Histo Sum sub tab of the 2 channel Histograms main tab The parameter alpha is configurable by 0.001/step. Histogram reset can be performed by the RESET HISTO button and the plot can be saved by the Save button with a user-defined prefix written in the HistoSum file name field SiPM Development Kit QuickStart Guide

20 The Correlation sub tab shows a scatter plot of the signals from the 2 sensors, after being integrated in the specified time window. It may be of help for specific applications relying on a simultaneous use of the 2 detectors, e.g. when using the scintillator tile for cosmic ray experiments or 2 spectrometry heads for 22Na positron annihilation detection. Fig. 2.10: Correlation sub tab of the 2 channel Histograms main tab 2473 SiPM Development Kit QuickStart Guide 20

21 The PSAU staircase tab allows the interaction with the PSAU in order to produce the so-called SiPM staircase: the plot shows the frequency of the signals which are over the threshold, during a scan from the min thr value up to max thr. value. The user can change these limits, the step, the number of read point which produce the mean plotted value and the gate width for the counting. Fig. 2.11: PSAU staircase tab Plot data can be saved by the save staircase button with a user-defined prefix of the output file written in the PSAU name file user field SiPM Development Kit QuickStart Guide

22 The PSAU counting tab plots the frequency of the signals over the threshold set in the Discriminator tab for the active channel. The user can change the number of points for the plotted mean value and the gate width for the counting. Fig. 2.12: PSAU counting tab 2473 SiPM Development Kit QuickStart Guide 22

23 3 Basic Measurements Kit configuration Required elements: PSAU + Digitizer + Oscilloscope Cabling instructions: o the kit elements shall be connected to the PC via the USB o the output from Channel 0 or 1 of the PSAU shall be directed to the oscilloscope Getting the system alive: o The PSAU and the Digitizer shall be powered on o The GUI launched and the Port assignment specified in the PSAU panel (below). o The Control system shall be activated for the fun to start! If the CommPort is wrongly selected, an error message will appear. Enjoying the first SiPM spectrum & measuring the Dark Count Rate Note: the measurements described in this chapter have been performed by using the SiPM Kit Control Software release 0.6. The tabs here presented can slightly differ from releases > 0.6. Once the system is running, the first action to take is properly biasing the detector and setting the right gain to avoid saturating the PSAU amplifier. As far as the optimal sensor bias, it is suggested to stick to the value reported on the sensor ID card, which may be set in the Bias & Gain tab of the PSAU panel (Figure 3). At the same time, the amplification factor can be set and, since the SiPM for the current measurement will not be illuminated and only a few cells are expected to fire, a high value can be used, e.g. 40 db. Moreover, for the sake of clarity, the feedback system for the SiPM gain stabilization against temperature variations can be disabled. Fig. 3.1: Bias & Gain tab of the GUI panel. As long as the SiPM is biased and the oscilloscope is properly triggered (an edge trigger, in manual mode, with a threshold at the -10 mv level should be suitable), the SiPM signal is expected to appear on the oscilloscope display, with a waveform similar to what is shown in Fig SiPM Development Kit QuickStart Guide

24 Fig. 3.2: SiPM output signal for a not illuminated sensor. Bias: V; Gain: 40 db. Peak-to-peak distance: mv. The different bands in the signal output correspond to avalanches in the cells triggered by the thermal generation of the charge carriers or by the photons associated to the avalanche development (optical cross-talk). The SiPM Geiger-Mueller multiplication factor is actually corresponding to the area underneath the single cell signal. However, the peak-to-peak distance provides a fair indication of the overall system gain, useful for checking the SiPM gain dependence on the over-voltage with respect to the breakdown set the amplification factor and avoid saturation effects set the discriminator threshold to generate a trigger condition and integrate the signal or perform counting experiments. A useful entry-level parameter is the Dark Count Rate (DCR) of the SiPM under study, namely the frequency with which avalanches occur for thermal or optical cross-talk (OXT) effects. It is a standard procedure to quantify the DCR as the counting frequency with a threshold corresponding to 0.5 x single photo-electron (p.e.) peak (DCR0.5) and to measure the OXT as DCR OXT DCR Being the numerator the Dark Count Rate with a threshold at 1.5 photoelectron peak. The DCR vs threshold can be precisely measured with the Kit. However, a fair indication can be obtained with the Oscilloscope, if the option to measure the triggering frequency is offered. In case, it is worth to exploit this feature to cross check the values against the factory measurements and as reference value for the most advanced procedures. As exemplary illustration, the DCR measurement at 0.5 Photoelectron threshold is shown in Fig SiPM Development Kit QuickStart Guide 24

25 Fig. 3.3: DCR 0.5 measurement at the oscilloscope. The frequency drops to ~206 KHz increasing the threshold to 1.5 p.e. (not shown). By now and before moving to the next step, the user can gain further knowledge on the system, playing with the bias and the amplification factor and measuring the peak-to-peak and DCR variations SiPM Development Kit QuickStart Guide

26 Can you see the light? SiPM illuminating; triggering & integrating Kit Configuration Required elements: PSAU + Digitizer + LED driver + Oscilloscope Cabling instructions: o the kit elements shall be connected to the PC via the USB o the LED output shall be directed to the SiPM through the FC terminated clear fiber o cabling among the kit elements depend on the undertaken measurement (see below) Getting the system alive: o Power on the kit elements o Start the system control and RUN the application o Verify the connection & error tabs for both the Digitizer and the PSAU o Bias the SiPM and set an initial amplification factor as of 0 o Initially no setting of the Digitizer and visualization panels are required Obtaining a multi-photon peak spectrum The multi-photon peak spectrum fully exploits the SiPM potential and it is the reference quantity for the detector characterisation and qualification. It corresponds to the output signal spectrum for an illuminated SiPM and carries information about the detector gain and noise, the photon number resolving capability and even the DCR and the cross talk; concerning the light source, it allows to characterize the statistics of the emitted photons. More will be reported in the following, after the first spectrum is obtained through a two-step procedure: Step 1: amplification factor and intensity tuning [LED driver + PSAU + Oscilloscope] The LED driver features the possibility to generate internally or externally the light pulse frequency; for the sake of simplicity, internal generation is considered here and the toggle switch on the back plane of the LED driver shall be set accordingly. The pulse frequency can be selected via a multi-turn rotary meter in the [6;500] khz range. When internal generation is chosen, a synchronization output signal in NIM logic is provided from the DOUT plug on the back panel. In order to know the frequency and as a trigger for the SiPM output visualization, it is recommended to look at the synch signal at the oscilloscope. Once this is done, the SiPM output from the PSAU can be properly displayed showing a number of fired cells by far exceeding what is due to the DCR and cross-talk. Looking at the scope track, the LED intensity can be tuned and the amplification factor regulated to avoid saturating the dynamic range and inducing an artefact in the spectrum (Fig. 3.4 and Fig. 3.5) SiPM Development Kit QuickStart Guide 26

27 Fig. 3.4: Analog output from the SiPM under test, illuminated the LED. The purple track, used as a trigger, correspondes to the synchronization signal form the LED driver. Fig. 3.5: Analog out from SiPM under test, showing onset of saturation due to a too large amplification factor SiPM Development Kit QuickStart Guide

28 Step 2: signal digitization In order to digitize the SiPM output, the kit has to be configured as follows: o o Cabling: The output signal form the PSAU has to be connected to the input of the Digitizer, either channel 0 or 1 The Synchronization signal from the LED will provide the trigger edge to the Digitizer and it has to be connected to the TRGIN plug o Software: in the Digitizer panel (Fig. 3.6), Select EXTERNAL trigger mode Select FIXED gate mode Select the active channel (0 or 1) Accept default values for the GATE and BASELINE sub-panels Fig. 3.6: The DIGITIZER control panel. By now, the system is ready for digitizing the signal but, rather than doing it in a blind way, it is worth taking a guided tour of the system features, going to the VISUALIZATION panel and switching ON the WAVE mode. The WAVE panel displays the most relevant information: a. The digitized analog INPUT b. The signal BASELINE c. The integration GATE, triggered externally or internally by the Digital Pulse Processor The BASELINE can be calculated according to the parameters specified in the corresponding sub-panel, namely: The number of samples used to calculate the mean value The threshold, used to avoid including in the mean value signals which could bias the baseline value. Whenever the signal exceeds the threshold while the baseline is being updated, the averaging procedure is frozen 2473 SiPM Development Kit QuickStart Guide 28

29 The no flat time, specifying the time interval between two updates of the baseline value. The flat time can also be shown in the WAVE display. The GATE actually defines the integration time and its edge may be triggered in different ways (see below). Once the GATE is open, its characteristics are associated to three parameters, specified in the GATE subpanel: The width The pre-gate, fully exploiting the digital power for the optimal timing with respect to the signal. It defines the position of the GATE with respect to the trigger edge, with the possibility to anticipate it, to compensate for the different timing in the signal routing. The hold-off time, a user s defined veto following a GATE opening. The hold-off can also be shown in the WAVE display. For the sake of clarity in the display, every signal can be OFFESET and MAGNIFIED, enabled or disabled. Fig. 3.7 is showing the WAVE panel for the SiPM illuminated by the LED, for optimal tuning of the baseline and notably of the pre-gate and the gate width, depending on the time development of the SiPM signal. It is worth remarking here that the LED driver was designed to provide light pulses with a few ns duration (see the technical specifications), so the time development is dominated by the sensor response. Fig. 3.7: The WAVE display of the GUI. As long as the GATE is properly defined, the system is ready to record the spectrum, displayed in the HISTOGRAM tab. Exemplary illustration of the multi-photon peak spectrum are shown in Fig SiPM Development Kit QuickStart Guide

30 Fig. 3.8: Multi-photon peak spectrum at two different LED intensities. The multi-photon peak spectrum provides several information about the system in use; it is worth recalling here the fundamentals: The SiPM multiplication factor can be measured by the peak-to-peak distance, knowing that the system is characterized by a charge LSB of 40 fc/adc channel and the SiPM signal is amplified by an amplification factor set by the user. The linearity and the dynamic range of the sensor can be studied as well. The photon number resolving power can be obtained at glance and its dependence on the SiPM biasing conditions studied A genuine multi-photon peak spectrum fit can provide further insight, namely: o o o A measurement of the width of the Gaussian peaks against the number n of cells, where a trend of the form n 2 Is expected, being 0 related to the zero-photon peak width, so to the system noise, and 1 provides an indication of the cell-to-cell variation of the characteristics. An independent measurement of the DCR and the cross-talk, as long as these terms are included in the fitting function An information on the statistics of the emitted photons, usually retained to be Poissonian. Moreover, the SiPM biasing can be optimized, trading-off the avalanche triggering efficiency and the spectrum quality, possibly affected by the spurious dark counts in the GATE window SiPM Development Kit QuickStart Guide 30

31 Can you see spectrum? Kit Configuration Required elements: PSAU + Digitizer + Spectrometer + [Oscilloscope] Cabling instructions: o o o o The PSAU and the Digitizer shall be connected to the PC via the USB The Spectrometer shall be connected to the PSAU in CH0 or CH1 position The correspondent CH out from the PSAU shall be connected to an input on the front panel of the digitizer; The correspondent DOUT from the PSAU shall be connected to the TRG IN on the front panel of the Digitizer Getting the system alive: o o o Power on the kit elements Start the system control, RUN the application and start the PSAU and the Digitizer Activate the connected PSAU channel and Digitizer channel Correctly bias the SiPM and set the gain The first action to take is biasing the SiPM and setting the right gain: set the bias according to the detector datasheet (in this example bias = 71.27V). For the gain, since the SiPM in the spectrometer application will be illuminated and a lots of cells are expected to fire, a low value can be used, e.g. 27 db. In this example, selecting a PSAU discriminating threshold of 10 mv (in the PSAU discriminating tab), a counting frequency around the 0.5 ph is obtained; in this way a Vpp = 20 mv is chosen. In Fig. 3.9 a typical trace of the spectrometer at the scope. Fig. 3.9: Scope trace of the spectrometer with a 137 Cs source SiPM Development Kit QuickStart Guide

32 External and internal trigger The SiPM development kit allows the user to trigger the digitizer for the acquisition of a source spectrum in two different ways: internally to the digitizer, selecting an appropriate threshold value (on delta signal) or externally to the digitizer, setting the discriminator threshold in the PSAU, through the PSAU discriminator tab, and using the correspondent NIM signal produced by the PSAU as a trigger signal for the digitizer itself. If the digitizer external trigger mode is selected, a threshold value on the PSAU discriminator tab shall be selected. A wrong choice of this value produce a wave similar to that in Fig. 3.10: the PSAU is triggering the signal on its noise. Increasing the threshold value the particle signal shall be clear, becoming similar to the wave of Fig Fig. 3.10: the wave for a wrong PSAU trigger threshold. Fig. 3.11: the wave for a right PSAU trigger threshold. How select the right external threshold value? Running a staircase (in the PSAU staircase tab) from -5mV to -100mV, the dark count rate decreases drastically from ~2 MHz to a value below 1 khz (Fig. 3.12). This example is performed with a 137 Cs source of an activity of 180 kbq, so, in order to remove all the dark count rate due to the nature of the sensor, a threshold of 100 mv can be selected (Fig. 3.13) SiPM Development Kit QuickStart Guide 32

33 Fig. 3.12: not so much staircase for SiPM 33-50C of spectrometer, in a run without source. Fig. 3.13: setting of PSAU threshold for NIM trigger for digitizer in PSAU discriminator tab. If digitizer internal trigger mode is selected, a threshold value (referring to delta signal) on the digitizer tab shall be selected. Fig shows the wave trace with correspondent delta and the gate. Fig. 3.14: wave (white) and delta (green) [Threshold =300; trigger mean =8; rise time =48]. As exemplary illustration, Fig shows a spectrum of 137 Cs obtained with the mini-spectrometer with the Hamamatsu 33-50C SiPM coupled with a 3x3x15 mm 2 CsI crystal; the set threshold is cutting the system noise peak and the 30KeV γ-line SiPM Development Kit QuickStart Guide

34 Fig. 3.15: 137 Cs spectrum SiPM Development Kit QuickStart Guide 34

35 Can you see a β particle? Kit Configuration Required elements: PSAU + Digitizer + Tile + [Oscilloscope] Cabling instructions: o o o o The PSAU and the Digitizer shall be connected to the PC via the USB The two SiPM heads shall be connected to the PSAU in CH0 and CH1 position The CH0 and CH1 out from the PSAU shall be connected to the two input on the front panel of the digitizer; The DOUT0 from the PSAU shall be connected to the TRG IN on the front panel of the digitizer Getting the system alive: o o o Power on the kit elements Start the system control, RUN the application and start the PSAU and the Digitizer Activate all the PSAU channels and all the Digitizer channels o o Bias the two SiPM and set an amplification factor as of 0 Setting the threshold and the coincidence When the system is up and running, the coincidence can be performed with the PSAU or internally the digitizer. If the PSAU is used to trigger the digitizer, the two channel thresholds and the coincidence width have to be set in the PSAU discriminator tab. The right choice of the two thresholds can be performed looking at the PSAU staircase run (one for each channel) as of 2.5.3: for example a threshold reducing the dark count rate of the SiPM to a level around [1;10] khz can be set. Figure 18 shows a SiPM stair case: setting a threshold of mv the DCR is reduced of a factor 2. Fig. 3.16: A typical 1x1 mm 2 SiPM stair case. After setting the thresholds for the two channels, the coincidence width shall be set in the PSAU discriminator tab (Fig. 3.17) SiPM Development Kit QuickStart Guide

36 Fig. 3.17: PSAU discriminator tab for setting threshold, coincidence width and output level. When the coincidence is ON, automatically the NIM coincidence signal is on the DOUT0. Setting the EXTERNAL trigger mode on the Digitizer tab, the spectrum will be obtained triggering the system by this external coincidence signal. The digitizer gate parameters shall be set in order to have a gate fitting the signal produced by the tile. In internal trigger mode, the digitizer requires the setting of the thresholds for the two channels, and the setting of the coincidence time (Fig. 3.18). Fig. 3.18: DIGITIZER tab: two channel thresholds are set and the coincidence is ON SiPM Development Kit QuickStart Guide 36

37 4 Functional Description SP Channels General Purpose Amplifier and Power Supply Unit Variable amplification gain (up to 50 db) Low noise, not to spoil the sensor performances for small signals Wideband, to comply with the fast sensor response Fast leading edge discriminator and time coincidence Provides the bias for the sensors with gain stabilization USB 2.0 interface Mechanical structure with an embedded SiPM 1 x 1 mm2 Dimension: 150 x 50 x 70 mm3 (WxHxD) The SP5600 is a General purpose Power Supply and Amplification Unit, integrating up to two SiPMs in a mother & daughter architecture allowing easy mounting and replacement of the sensors. The basic configuration features two channels with indipendent gain control up to 50 db and provides the bias voltage (up to 120 V) to the sensors with gain stabilization. Each channel can provide a digital output generated by the fast leading edge discriminators. A timing coincidence of the two channels is also available. DT5720A 2 Channel 12 bit 250 MS/s Digitizer 2 Channel 12 bit 250 MS/s Digitizer Digital Pulse Processing for Charge Integration DPP-CI Best suited for PMT and SiPM/MPPC readout at low and high rates Mid-High speed signals (Typ: output of PMT/SiPM) Good timing resolution with fast signals (rise time < 100 ns) Optical Link and USB 2.0 interfaces Dimension: 154 x 50 x 164 mm 3 (WxHxD) The DT5720A is a 2 Channel 12 bit 250 MS/s Desktop Waveform Digitizer with 2 Vpp single ended input dynamics on MCX coaxial connectors. The DC offset adjustment (range ± 1 V) by programmable 16bit DACs (one for each channel) allows a right sampling of a bipolar (Vin = ±1 V) up to a full positive (Vin = 0 +2 V) or negative (Vin = 0-2 V) analog input swing without losing dynamic resolution. The module features a front panel Clock Input and a PLL for clock synthesis from internal/external references. The data stream is continuously written in a circular memory buffer. When the trigger occurs, the FPGA writes further N samples for the post trigger and freezes the buffer that can be read by USB or Optical Link. The acquisition can continue without dead time in a new buffer SiPM Development Kit QuickStart Guide

38 Each channel has a SRAM memory buffer (1.25 MS/ch) divided into buffers of programmable size (1 1024). The readout (by USB or Optical Link) of a frozen buffer is independent from the write operations in the active circular buffer (ADC data storage). The trigger signal can be provided externally via the front panel Trigger Input as well as via the software, but it can also be generated internally thanks to threshold self-trigger capability. DT5720A houses USB 2.0 and Optical Link interfaces. USB 2.0 allows data transfers up to 30 MB/s. The Optical Link supports transfer rate of 80 MB/s and offer Daisy chain capability. Therefore it is possible to connect up to 8/32 ADC modules to a single Optical Link Controller (Mod. A2818/A3818). Dt5720 is equipped with a Digital Pulse Processing firmware for Physics Applications (DPP-CI Digital Pulse Processing for the Charge Integration). This feature allows to perform on-line processing on detector signal directly digitized. DT5720A is well suited for data acquisition and processing of signals from scintillators/photomultipliers or SiPM detectors, implementing a digital version of the traditional QDC (Charge-to-Digital Converter). The digitizer runs on real time: SP5601 LED Driver Self Trigger using CR-RC digital Time filter algorithm Input signal baseline (pedestal) calculation Charge Integration (with programmable gate parameters) with pedestal subtraction for energy calculation Width of pulse ns LED color: violet (400nm) 1500 mcd Pulse generator: internal/external Optical output connectors: FC Optical fiber included Dimension: 79 x 42 x 102 mm 3 (WxHxD) The SP5601 is an ultra-fast LED Driver with pulse width at ns level, tunable intensity and frequency that provides a low-cost tool for the detector characterization. The LED pulse generation can be triggered by an internal oscillator or by an external pulser. SP5602 Scintillating Tile Sensitive volume: 150 x 150 x 10 mm 3 Scintillator: polystyrene Light guide: embedded WLS fiber Output connectors: FC Dimension: 200 x 150 x 10 mm 3 (WxHxD) The SP5602 is a plastic scintillating tile, with a WLS fiber embedded to collect the scintillator light, FC terminated. The tile, with a sensitive volume of 150 x 150 x 10 mm 3, is the ideal tool for tests with beta emitting isotopes and cosmic rays SiPM Development Kit QuickStart Guide 38

39 SP5603 Mini Spectrometer Mechanical structure for optimal SiPM to crystal coupling Crystal dimensions: 3 x 3 x 15 mm 3 Included crystals: LYSO, BGO, Csl One SiPM 3 x 3 mm 2 embedded Dimension: 40 mm (D), 35 mm (L) The SP5603 is a mini-spectrometer for gamma ray detection. The spectrometer is composed by a mechanical structure that houses a scintillating crystal, coupled to a dedicated 3 x 3 mm 2 SiPM. Three crystals (LYSO, BGO, CsI) are also provided. The spectrometer s design allows an easy connection to the SP SiPM Development Kit QuickStart Guide

40 Tools for Discovery n CAEN SpA is acknowledged as the only company in the world providing a complete range of High/Low Voltage Power Supply systems and Front-End/Data Acquisition modules which meet IEEE Standards for Nuclear and Particle Physics. Extensive Research and Development capabilities have allowed CAEN SpA to play an important, long term role in this field. Our activities have always been at the forefront of technology, thanks to years of intensive collaborations with the most important Research Centres of the world. Our products appeal to a wide range of customers including engineers, scientists and technical professionals who all trust them to help achieve their goals faster and more effectively. CAEN S.p.A. CAEN GmbH CAEN Technologies, Inc. Via Vetraia, 11 Klingenstraße Bay Street - Suite 2 C Viareggio D Solingen Staten Island, NY Italy Germany USA Tel Tel. +49 (0) Tel Fax Mob. +49 (0) Fax info@caen.it Fax +49 (0) info@caentechnologies.com info@caen-de.com CAEN Tools for Discovery Guide GD SiPM Development Kit QuickStart Guide rev March SIPM0-GXXX Copyright CAEN SpA. All rights reserved. Information in this publication supersedes all earlier versions. Specifications subject to change without notice SiPM Development Kit QuickStart Guide 40

Silicon PhotoMultiplier Kits

Silicon PhotoMultiplier Kits Silicon PhotoMultiplier Kits Silicon PhotoMultipliers (SiPM) consist of a high density (up to ~ 10 3 /mm 2 ) matrix of photodiodes with a common output. Each diode is operated in a limited Geiger- Müller

More information

CAEN Tools for Discovery

CAEN Tools for Discovery Viareggio March 28, 2011 Introduction: what is the SiPM? The Silicon PhotoMultiplier (SiPM) consists of a high density (up to ~10 3 /mm 2 ) matrix of diodes connected in parallel on a common Si substrate.

More information

Operating Instructions

Operating Instructions Operating Instructions HAEFELY TEST AG KIT Measurement Software Version 1.0 KIT / En Date Version Responsable Changes / Reasons February 2015 1.0 Initial version WARNING Introduction i Before operating

More information

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park Overview We have developed a system for measuring and scanning phototubes for the FDIRC Based primarily on

More information

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. Multichannel Scaler Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. The ideal solution for: Time-resolved single-photon counting Phosphorescence lifetime spectrometry Atmospheric and

More information

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband

More information

CAEN. Electronic Instrumentation. UM2580 DPSD User Manual. Rev June Rev June Tools for Discovery

CAEN. Electronic Instrumentation. UM2580 DPSD User Manual. Rev June Rev June Tools for Discovery Tools for Discovery n Rev 3-05 June 2013 UM2580 DPSD User Manual Rev 3 05 June 2013 Purpose of this Manual This User Manual contains the full description of the Digital Pulse Shape Discrimination for 720

More information

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1] www.analogarts.com Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1] 1. These models consist of an oscilloscope, a spectrum analyzer, a data recorder, and a frequency & phase meter. Oscilloscope/

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System 7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key

More information

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High Performance, Multifunction USB DAQ Key Features: Simultaneous subsystem operation on up to 32 analog input channels,

More information

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The

More information

The Measurement Tools and What They Do

The Measurement Tools and What They Do 2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying

More information

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator 20 Channel Digital Delay Generator Features of the 745T-20C: 20 Independent delay channels - 100 ps resolution - 25 ps rms jitter - 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every

More information

SignalTap Plus System Analyzer

SignalTap Plus System Analyzer SignalTap Plus System Analyzer June 2000, ver. 1 Data Sheet Features Simultaneous internal programmable logic device (PLD) and external (board-level) logic analysis 32-channel external logic analyzer 166

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three

More information

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features: DT9837 Series High Performance, Powered Modules for Sound & Vibration Analysis The DT9837 Series high accuracy dynamic signal acquisition modules are ideal for portable noise, vibration, and acoustic measurements.

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

Spectrum Analyser Basics

Spectrum Analyser Basics Hands-On Learning Spectrum Analyser Basics Peter D. Hiscocks Syscomp Electronic Design Limited Email: phiscock@ee.ryerson.ca June 28, 2014 Introduction Figure 1: GUI Startup Screen In a previous exercise,

More information

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices Audio Converters ABSTRACT This application note describes the features, operating procedures and control capabilities of a

More information

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Analog Arts SA985 SA975 SA935 SA915 Product Specifications Analog Arts SA985 SA975 SA935 SA915 Product Specifications Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1]

More information

GALILEO Timing Receiver

GALILEO Timing Receiver GALILEO Timing Receiver The Space Technology GALILEO Timing Receiver is a triple carrier single channel high tracking performances Navigation receiver, specialized for Time and Frequency transfer application.

More information

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel) Digital Delay / Pulse Generator Digital delay and pulse generator (4-channel) Digital Delay/Pulse Generator Four independent delay channels Two fully defined pulse channels 5 ps delay resolution 50 ps

More information

MTL Software. Overview

MTL Software. Overview MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

PicoScope 6407 Digitizer

PicoScope 6407 Digitizer YE AR HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis

More information

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies Agilent Technologies N5106A PXB MIMO Receiver Tester Messages Agilent Technologies Notices Agilent Technologies, Inc. 2008 2009 No part of this manual may be reproduced in any form or by any means (including

More information

BER MEASUREMENT IN THE NOISY CHANNEL

BER MEASUREMENT IN THE NOISY CHANNEL BER MEASUREMENT IN THE NOISY CHANNEL PREPARATION... 2 overview... 2 the basic system... 3 a more detailed description... 4 theoretical predictions... 5 EXPERIMENT... 6 the ERROR COUNTING UTILITIES module...

More information

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Lab 1 Introduction to the Software Development Environment and Signal Sampling ECEn 487 Digital Signal Processing Laboratory Lab 1 Introduction to the Software Development Environment and Signal Sampling Due Dates This is a three week lab. All TA check off must be completed before

More information

Beam test of the QMB6 calibration board and HBU0 prototype

Beam test of the QMB6 calibration board and HBU0 prototype Beam test of the QMB6 calibration board and HBU0 prototype J. Cvach 1, J. Kvasnička 1,2, I. Polák 1, J. Zálešák 1 May 23, 2011 Abstract We report about the performance of the HBU0 board and the optical

More information

Datasheet SHF A

Datasheet SHF A SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax ++49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 19120 A 2.85 GSa/s

More information

TransitHound Cellphone Detector User Manual Version 1.3

TransitHound Cellphone Detector User Manual Version 1.3 TransitHound Cellphone Detector User Manual Version 1.3 RF3 RF2 Table of Contents Introduction...3 PC Requirements...3 Unit Description...3 Electrical Interfaces...4 Interface Cable...5 USB to Serial Interface

More information

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note Overview The Broadcom AFBR-S4N44P163 4 x 4 element silicon photomultiplier array and Vertilon SIB916 sensor interface board are an ideal combination for use in coincidence detection applications such as

More information

GFT channel Time Interval Meter

GFT channel Time Interval Meter Key Features Five-channel Time-Interval Meter: One Start and four Stops - 13 picosecond resolution - < 50 picosecond RMS jitter - > 100 second range - 10 MHz sample rate per channel Common GATE input Input

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Data Acquisition System for Segmented Reactor Antineutrino Detector

Data Acquisition System for Segmented Reactor Antineutrino Detector Data Acquisition System for Segmented Reactor Antineutrino Detector Z. Hons a,b,*, J. Vlášek a,c,d a Joint Institute for Nuclear Research, Moscow Region, Dubna, Russian Federation b NPI Nuclear Physics

More information

2 MHz Lock-In Amplifier

2 MHz Lock-In Amplifier 2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display

More information

Boonton 4540 Remote Operation Modes

Boonton 4540 Remote Operation Modes Application Note Boonton 4540 Remote Operation Modes Mazumder Alam Product Marketing Manager, Boonton Electronics Abstract Boonton 4540 series power meters are among the leading edge instruments for most

More information

PicoScope 6407 Digitizer

PicoScope 6407 Digitizer YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator

More information

Driver circuit for MPPC

Driver circuit for MPPC Simple evaluation starter kit for non-cooled s The is a starter kit designed for simple non-cooled evaluations. It consists of a sensor board and a power supply board. The sensor board includes an socket

More information

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes Forschungszentrum Jülich Internal Report No. FZJ_2013_02988 Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes Riccardo Fabbri a arxiv:1307.1426v1 [physics.ins-det]

More information

STB Front Panel User s Guide

STB Front Panel User s Guide S ET-TOP BOX FRONT PANEL USER S GUIDE 1. Introduction The Set-Top Box (STB) Front Panel has the following demonstration capabilities: Pressing 1 of the 8 capacitive sensing pads lights up that pad s corresponding

More information

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods

More information

DRAFT RELEASE FOR BETA EVALUATION ONLY

DRAFT RELEASE FOR BETA EVALUATION ONLY IPM-16 In-Picture Audio Metering User Manual DRAFT RELEASE FOR BETA EVALUATION ONLY Ver 0.2 April 2013 1 Contents Introduction...3 In Picture Audio Meter Displays...4 Installation...7 External Audio Board

More information

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM COMPONENT TEST PLATFORM Efficiently test passive components in 24/7 operation. Perform single sweep insertion loss and return loss measurements with unprecedented dynamic range, speed and resolution. SPEC

More information

ivw-ud322 / ivw-ud322f

ivw-ud322 / ivw-ud322f ivw-ud322 / ivw-ud322f Video Wall Controller Supports 2 x 2, 2 x 1, 3 x 1, 1 x 3, 4 x 1 & 1 x 4 Video Wall Array User Manual Rev. 1.01 i Notice Thank you for choosing inds products! This user manual provides

More information

EAN-Performance and Latency

EAN-Performance and Latency EAN-Performance and Latency PN: EAN-Performance-and-Latency 6/4/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com

More information

A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays

A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays H. Tan, J. W. Collins, M. Walby, W. Hennig, W. K. Warburton, P. Grudberg XIA LLC, 3157 Genstar Rd, Hayward, CA 94544,

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

013-RD

013-RD Engineering Note Topic: Product Affected: JAZ-PX Lamp Module Jaz Date Issued: 08/27/2010 Description The Jaz PX lamp is a pulsed, short arc xenon lamp for UV-VIS applications such as absorbance, bioreflectance,

More information

PicoScope 4000 Automotive PC Oscilloscopes

PicoScope 4000 Automotive PC Oscilloscopes PicoScope 4000 Automotive PC Oscilloscopes User's Manual ps4000a.en-1 Copyright 2008 Pico Technology Ltd. All rights reserved. Contents I Contents 1 Introduction...1 1 Overview...1...1 2 Minimum PC requirements...2

More information

Front End Electronics

Front End Electronics CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration

More information

This guide gives a brief description of the ims4 functions, how to use this GUI and concludes with a number of examples.

This guide gives a brief description of the ims4 functions, how to use this GUI and concludes with a number of examples. Quick Start Guide: Isomet ims Studio Isomet ims Studio v1.40 is the first release of the Windows graphic user interface for the ims4- series of 4 channel synthezisers, build level rev A and rev B. This

More information

Digital Storage Oscilloscopes 2550 Series

Digital Storage Oscilloscopes 2550 Series Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz

More information

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels DT9857E Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels The DT9857E is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements

More information

Fluke 190-Series II Firmware Upgrade V11.44

Fluke 190-Series II Firmware Upgrade V11.44 Fluke 190-Series II Firmware Upgrade V11.44 Requirements 1. Fluke 190- Series II ScopeMeter with firmware prior to V11.44 2. Supported models are: 190-102, 190-104, 190-062, 190-202, 190-204, 190-502,

More information

Oscilloscopes, logic analyzers ScopeLogicDAQ

Oscilloscopes, logic analyzers ScopeLogicDAQ Oscilloscopes, logic analyzers ScopeLogicDAQ ScopeLogicDAQ 2.0 is a comprehensive measurement system used for data acquisition. The device includes a twochannel digital oscilloscope and a logic analyser

More information

Front End Electronics

Front End Electronics CLAS12 Ring Imaging Cherenkov (RICH) Detector Mid-term Review Front End Electronics INFN - Ferrara Matteo Turisini 2015 October 13 th Overview Readout requirements Hardware design Electronics boards Integration

More information

KLM: TARGETX. User-Interface for Testing TARGETX Brief Testing Overview Bronson Edralin 04/06/15

KLM: TARGETX. User-Interface for Testing TARGETX Brief Testing Overview Bronson Edralin 04/06/15 KLM: TARGETX User-Interface for Testing TARGETX Brief Testing Overview Bronson Edralin 1 TARGETX Test Team TARGETX Waveform Sampling/Digitizing ASIC Designer Dr. Gary S. Varner Features 1 GSa/s 16 Channels

More information

LeCroy Digital Oscilloscopes

LeCroy Digital Oscilloscopes LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,

More information

Major Differences Between the DT9847 Series Modules

Major Differences Between the DT9847 Series Modules DT9847 Series Dynamic Signal Analyzer for USB With Low THD and Wide Dynamic Range The DT9847 Series are high-accuracy, dynamic signal acquisition modules designed for sound and vibration applications.

More information

Driver circuit for CMOS linear image sensor

Driver circuit for CMOS linear image sensor Driver circuit for CMOS linear image sensor C13015-01 For CMOS linear image sensor S11639-01, etc. The C13015-01 is a driver circuit developed for Hamamatsu CMOS linear image sensor S11639-01, etc. By

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

MAP Optical Power Meter Module (mopm-b1)

MAP Optical Power Meter Module (mopm-b1) COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MAP Optical Power Meter Module (mopm-b1) Key Features Panel mount or remote head configuration Single, dual, or quad channel configurations available 250 khz

More information

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module Introduction The vibration module allows complete analysis of cyclical events using low-speed cameras. This is accomplished

More information

DPD80 Visible Datasheet

DPD80 Visible Datasheet Data Sheet v1.3 Datasheet Resolved Inc. www.resolvedinstruments.com info@resolvedinstruments.com 217 Resolved Inc. All rights reserved. General Description The DPD8 is a low noise digital photodetector

More information

Signal Stability Analyser

Signal Stability Analyser Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)

More information

USB Smart Power Sensor

USB Smart Power Sensor 75Ω -30 dbm to +20 dbm, 100 khz to 2500 MHz The Big Deal 75Ω Impedance Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface)

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

medlab One Channel ECG OEM Module EG 01000

medlab One Channel ECG OEM Module EG 01000 medlab One Channel ECG OEM Module EG 01000 Technical Manual Copyright Medlab 2012 Version 2.4 11.06.2012 1 Version 2.4 11.06.2012 Revision: 2.0 Completely revised the document 03.10.2007 2.1 Corrected

More information

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum

More information

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram features 4 / 8 / 16 channel LevelMagic2 SDI-DSP with level or loudness (ITU-BS.1770-1/ ITU-BS.1770-2, EBU R128) control 16 channel 3G/HD/SD-SDI de-embedder 16 in 16 de-embedder matrix 16 channel 3G/HD/SD-SDI

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

USB Smart Power Sensor

USB Smart Power Sensor 50Ω -30 dbm to +20 dbm, 1 MHz to 8000 MHz The Big Deal Fast measurement speed, 10 msec USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface)

More information

DPD80 Infrared Datasheet

DPD80 Infrared Datasheet Data Sheet v1.4 DPD8 Infrared DPD8 Infrared Datasheet Resolved Inc. www.resolvedinstruments.com info@resolvedinstruments.com 217 Resolved Inc. All rights reserved. DPD8 Infrared General Description The

More information

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area. BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features

More information

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

FCPM-6000RC. Mini-Circuits  P.O. Box , Brooklyn, NY (718) USB / Ethernet Integrated Frequency Counter & Power Meter 50Ω -30 dbm to +20 dbm, 1 MHz to 6000 MHz The Big Deal Automatically synchronized power & frequency measurements USB and Ethernet control Includes

More information

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Manual of Operation for WaveNode Model WN-2m. Revision 1.0 Manual of Operation for WaveNode Model WN-2m. Revision 1.0 TABLE OF CONTENTS 1. Description of Operation 2. Features 3. Installation and Checkout 4. Graphical Menus 5. Information for Software Expansion

More information

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

NanoGiant Oscilloscope/Function-Generator Program. Getting Started Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose

More information

LAX_x Logic Analyzer

LAX_x Logic Analyzer Legacy documentation LAX_x Logic Analyzer Summary This core reference describes how to place and use a Logic Analyzer instrument in an FPGA design. Core Reference CR0103 (v2.0) March 17, 2008 The LAX_x

More information

Driver circuit for InGaAs linear image sensor

Driver circuit for InGaAs linear image sensor Driver circuit for InGaAs linear image sensor [G11620 series (non-cooled type)] The is a driver circuit developed for InGaAs linear image sensors [G11620 series (non-cooled type)]. The driver circuit consists

More information

Introduction To LabVIEW and the DSP Board

Introduction To LabVIEW and the DSP Board EE-289, DIGITAL SIGNAL PROCESSING LAB November 2005 Introduction To LabVIEW and the DSP Board 1 Overview The purpose of this lab is to familiarize you with the DSP development system by looking at sampling,

More information

ATS50SAW Programmable Selective Amplifier

ATS50SAW Programmable Selective Amplifier ATS50SAW Programmable Selective Amplifier Technical Specifications N Input BI/BII (40 108 MHz) 1 N Input BIII/DAB (170 320 MHz) 1 N AUX input (40 860 MHz) 1 N Programmable Input UHF (470 790 MHz) 4 N IF-SAT

More information

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement MTI-2100 Fotonic TM Sensor Unmatched Resolution and

More information

Release Notes for LAS AF version 1.8.0

Release Notes for LAS AF version 1.8.0 October 1 st, 2007 Release Notes for LAS AF version 1.8.0 1. General Information A new structure of the online help is being implemented. The focus is on the description of the dialogs of the LAS AF. Configuration

More information

Scanning For Photonics Applications

Scanning For Photonics Applications Scanning For Photonics Applications 1 - Introduction The npoint LC.400 series of controllers have several internal functions for use with raster scanning. A traditional raster scan can be generated via

More information

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat WaveNow USB Potentiostat / Galvanostat WaveNow / WaveNowXV Portable USB Potentiostat WaveNano Low-Current Portable USB Potentiostat Part Numbers Product Name WaveNow WaveNano WaveNowXV Description Portable

More information

C Module Description

C Module Description IQMMX -Input Router & ASI Distribution Amplifier C Module Description The IQMMX is an ASI to 1 switch, distribution amplifier and transport stream switcher with up to 8 outputs in double width form or

More information

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Products: R&S RTO2002 R&S RTO2004 R&S RTO2012 R&S RTO2014 R&S RTO2022 R&S RTO2024 R&S RTO2044 R&S RTO2064 This application

More information

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X HMS-X_bro_de-en_3607-0181-3X_v0200.indd 1 Product Brochure 02.00 Test & Measurement Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X 15.03.2016 15:24:06 1 Basic Unit + 3 Options Key facts Frequency range: 100

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

PicoScope 4000 Series PC Oscilloscopes

PicoScope 4000 Series PC Oscilloscopes PicoScope 4000 Series PC Oscilloscopes User's Guide -1 Contents I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warning 4 FCC notice 5 CE notice...2...2...2...3...3...3

More information

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV INSTRUCTION MANUAL HD-4000 Series OPENGEAR SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV MultiDyne Video at Light Speed 191 FOREST AVENUE LOCUST VALLEY, NY 11560-2132

More information

InGaAs multichannel detector head

InGaAs multichannel detector head Near infrared line camera (Line rate: 31.25 khz) The is a multichannel detector head suitable for applications where high-speed response is required, such as SD- OCT (spectral domain-optical coherence

More information

MPPC modules. MPPC array modules for very-low-level light detection, 16 ch analog output. C13368/C13369 series (Analog output type)

MPPC modules. MPPC array modules for very-low-level light detection, 16 ch analog output.   C13368/C13369 series (Analog output type) MPPC modules C13368/C13369 series (Analog output type) MPPC array modules for very-low-level light detection, 16 ch analog output The C13368/C13369 series (analog output type) is an optical measurement

More information

THE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS

THE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS THE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS A. O. Borga #, R. De Monte, M. Ferianis, L. Pavlovic, M. Predonzani, ELETTRA, Trieste, Italy Abstract Several diagnostic

More information

WaveDriver 20 Potentiostat/Galvanostat System

WaveDriver 20 Potentiostat/Galvanostat System WaveDriver 20 Potentiostat / Galvanostat WaveDriver 20 Potentiostat/Galvanostat System Electrode Connections Cell Port Reference Electrode Counter Electrode First Working Electrode Second Working Electrode

More information

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL COMPOSITE VIDEO METER MODEL VLM- COMPOSITE VIDEO METER MODEL VLM- NTSC TECHNICAL INSTRUCTION MANUAL VLM- NTSC TECHNICAL INSTRUCTION MANUAL INTRODUCTION EASY-TO-USE VIDEO LEVEL METER... SIMULTANEOUS DISPLAY...

More information

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved. PicoScope 2203 PC Oscilloscopes User's Guide PicoScope 2203 User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warning 4 FCC notice 5 CE notice...2...2...3...4...4...5

More information