1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions
|
|
- Sylvia Kelly
- 6 years ago
- Views:
Transcription
1 1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions 1.1 Click on the OMNIC icon to open the software. 1.2 Check that a signal is being measured by opening the Experiment Setup menu under the Collect tab and go to the Bench tab. You should see a peak centered in the left window with a Max value around between 9 and If you have problems seeing a signal, or the signal is low, you can realign the mirrors to obtain an optimum signal. Go into the Diagnostic tab and click on the Align button. 1.4 Click on the Collect tab and setup the experiment 1. No. of scans: Number of scans to acquire background and spectrum. Default is Resolution: Resolution of the spectrum can be adjusted for course or fine details. Resolution range is between 32 and Default value is Experiment title: This is required and used to identify the experiment 4. Background Handling: Recommend to select Collect background before every sample. This will prompt the user to collect a background spectrum before each sample. JHU CORE FACILITIES 1 Dr. Joel A. Tang
2 1.5 Go back to the Bench tab to adjust the spectral window. Max range is between 4000 and 400 cm -1. Click OK button to exit the Experiment setup. 1.6 On the left side of the window, there are two buttons: Collect background, Collect Sample If the option to Collect background before every sample is selected, you can just click on collect Sample button. 1.7 It will first ask to prepare sample chamber for background collection. 1.8 Select proper sample assembly and place in sample chamber. (a) (b) There many types of sample holders such as (right) for slides (KBr disk, glass slide etc.) or (left) for liquids/solutions. The sample holder slides into the sample chamber support with the sample facing the right. There is also an ATR attachment (see below) for both solutions and solid samples. 1.9 Place background material into the sample chamber (KBr disk, solvent etc ) and click OK Once the background is collected, you can insert your sample. A prompt will show and you can enter a title for your spectrum. Click OK when ready to collect sample During acquisition, you can select which window to add the spectrum to when completed. If you want to put them in separate windows select Add to new window in the drop down menu above the spectrum. JHU CORE FACILITIES 2 Dr. Joel A. Tang
3 1.12 Peak positions can be determined through the Analyze menu and Find Peaks option In the spectrum window you can adjust the peak picking threshold by clicking on the spectrum and adjusting the location of the horizontal line. The sensitivity of the peak picking can be adjusted by the siding bar on the left of the spectrum Once peaks are selected you can choose to replace the original spectrum, or add it to a different window. To avoid confusion, select Replace the original spectrum and click on Replace button. JHU CORE FACILITIES 3 Dr. Joel A. Tang
4 1.15 You can save your data on the local hard drive C:\IR data\ Group \ User Name where Group is your PI name and User Name is your JHED id. The file can be saved under different formats: Spectra (*.spa) Standard spectra file format, read in by OMNIC CSV Text (*.csv) Comma-separated values, text file containing data points to be read in by a spreadsheet program (e.g. Excel, Origin). Does not save peak labels. Windows Metafile (*.WMF) / TIFF (*.TIF) image file format. Saves what is seen in the spectrum window. JHU CORE FACILITIES 4 Dr. Joel A. Tang
5 2.0 Nicolet Smart Golden Gate, KRS-5 ATR Accessory 2.1 The ATR accessory is in a black plastic case under the counter in the cabinet. Take it out carefully and lay it on the counter. 2.2 Remove the sample support platform from the FTIR. There is a small peg in the back restricting it to slide forward. Use the hole in the front to lift the plate up. The software will detect that the plate has been removed. 2.3 Take out the ATR and insert into the FTIR from the top. The round openings on the side of the ATR, under the case, will align with the open slots for the laser/detector of the sample chamber. 2.4 The software will automatically detect that the ATR was installed and read in default experiment settings. Go back under the Collect menu -> Experiment Setup -> Bench tab and a peak should again be detected, but at a lower level (should be around 2). If you have problems seeing a signal you can realign the mirrors to obtain an optimum signal. Go into the Diagnostic tab and click on the Align button. JHU CORE FACILITIES 5 Dr. Joel A. Tang
6 2.5 Lift up the golden gate by unscrewing the left latch. Clean the crystals on the platform and the tip with methanol. 2.6 Lower the arm and re-latch in place. Turn the top knob to compress the two crystals together. ONLY TURN UNTIL FINGER TIGHT. Collect a background spectrum. 2.7 Turn the knob to loosen the compression and lift the arm to place your sample. Directly place the solid or liquid sample onto the crystal on the platform. For solids: lower arm and turn the knob again until finger tight. For liquids: Place cap on top to prevent evaporation of volatile solutions. DO NOT COMPRESS THE ARM ON TOP OF CAP. 2.8 Collect data by following steps 10 to 15 in Section When you are finished clean the crystals carefully and put the disassembled apparatus back in the case. Replace the standard cell holder. JHU CORE FACILITIES 6 Dr. Joel A. Tang
Standard Operating Procedure of nanoir2-s
Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),
More informationQuick Start Bruker Dimension Icon AFM
Do not remove Quick Start Bruker Dimension Icon AFM March 3, 2015 GLA Contacts Harold Fu (hfu@caltech.edu) Weilai Yu (wyyu@caltech.edu) Bruker Tech Support (AFMSupport@bruker-nano.com 800-873-9750) Watch
More informationProcessing data with Mestrelab Mnova
Processing data with Mestrelab Mnova This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and
More informationNoise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0
CHEM 411L Instrumental Analysis Laboratory Revision 2.0 Noise In this laboratory exercise we will determine the Signal-to-Noise (S/N) ratio for an IR spectrum of Air using a Thermo Nicolet Avatar 360 Fourier
More informationFigure 1. MFP-3D software tray
Asylum MFP-3D AFM SOP January 2017 Purpose of this Instrument: To obtain 3D surface topography at sub-nanometer scale resolution, measure contact and friction forces between surfaces in contact, measure
More informationVasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer
Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer solvents) Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml
More informationDektak Step by Step Instructions:
Dektak Step by Step Instructions: Before Using the Equipment SIGN IN THE LOG BOOK Part 1: Setup 1. Turn on the switch at the back of the dektak machine. Then start up the computer. 2. Place the sample
More informationData Collection Using APEX3. March 30, Chemical Crystallography Laboratory
Data Collection Using APEX3 Page 1 of 10 Data Collection Using APEX3 March 30, 2017 Chemical Crystallography Laboratory Author: Douglas R. Powell Data Collection Using APEX3 Page 2 of 10 Distribution Douglas
More informationPreface... Specification...14
Contents for V680L Operating Manual Preface......3 Important safety tips...3 Accessories of product...4 Icons of product...5 Installation support...7 Description for operating steps... 8 Description for
More informationPHI 5000 VersaProbe TM Operator s Guide
PHI 5000 VersaProbe TM Operator s Guide Part No. 705921 Rev. A Copyright 2006 ULVAC-PHI, INC. 370 Enzo, Chigasaki, JAPAN The PHI logo ( ) is a registered trademark of ULVAC-PHI, INC. Physical Electronics,
More informationStandard Operating Procedure II: EDS (Bruker Flat-Quad)
Standard Operating Procedure II: EDS (Bruker Flat-Quad) ywcmatsci.yale.edu ESC II, Room A119F 810 West Campus Drive West Haven, CT 06516 Version 1.1, October 2018 1 > FOLLOW the SOP strictly to keep the
More informationTL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL
TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL DATA ACQUISITION SYSTEM V.15.4 INSTRUCTION MANUAL Timberline Instruments, LLC 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx:
More informationDURATECH FINISH ANALYZER
DURATECH FINISH ANALYZER MIDAC M2000 FTIR UPGRADE MANUAL This manual contains additional information concerning the extraction unit settings, not found in the extraction unit hardware manual. Please read
More informationSTANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM
STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM Purpose of this Instrument: To obtain 3D surface topography at sub-nanometer scale resolution, measure contact and friction forces between surfaces in contact,
More informationREAD THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1
READ THIS FIRST Morphologi G3 Quick Start Guide MAN0412 Issue1.1 Malvern Instruments Ltd. 2008 Malvern Instruments makes every effort to ensure that this document is correct. However, due to Malvern Instruments
More informationStandard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology
Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology Before starting with the CytoFLEX S Flow Cytometer: 1. A new user needs to get an introduction to the flow cytometer
More informationContents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.
Rigel 1550 Terahertz Spectrometer User Manual Contents info@tetechs.com 1. System Description 3 Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7 2. Safety 9 Laser Safety 9 Electrical
More informationDifferential Scanning Calorimetry (DSC) Of Powder Coating Materials
Differential Scanning Calorimetry (DSC) Of Powder Coating Materials Introduction This manual provides instructions to prepare samples for and subsequently perform a DSC (differential scanning calorimetry)
More informationIMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface)
IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface) Last updated: October 12, 2011 by Josh Kurutz THIS PAGE = QUICK START GUIDE 0) At the computer, make sure VNMRJ is
More informationUser Manual OVP Raman
Version 6 User Manual OVP Raman 2006 BRUKER OPTIK GmbH, Rudolf-Plank-Straße 27, D-76275 Ettlingen, www.brukeroptics.com All rights reserved. No part of this manual may be reproduced or transmitted in any
More informationTechnical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework
Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework 1.0 Purpose This technical procedure shall be followed for the operation of the Scanning
More informationDektakXT Profilometer. Standard Operating Procedure
DektakXT Profilometer Standard Operating Procedure 1. System startup and sample loading: a. Ensure system is powered on by looking at the controller to the left of the computer.(it is an online software,
More informationImport and quantification of a micro titer plate image
BioNumerics Tutorial: Import and quantification of a micro titer plate image 1 Aims BioNumerics can import character type data from TIFF images. This happens by quantification of the color intensity and/or
More informationChapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle
Chapter 2: Scanner Operations This chapter explains general Scanner operations and offers instructions for customizing certain Scanner functions. The following is an outline of basic Scanner operation.
More informationSEM- EDS Instruction Manual
SEM- EDS Instruction Manual Double-click on the Spirit icon ( ) on the desktop to start the software program. I. X-ray Functions Access the basic X-ray acquisition, display and analysis functions through
More informationSyntor X Flash Memory Module Revision C
Syntor X Flash Memory Module Revision C The PIEXX SynXFlash memory module, along with the supplied PC software, replaces the original SyntorX code plugs and allows you to easily set modify and update your
More informationReference. TDS7000 Series Digital Phosphor Oscilloscopes
Reference TDS7000 Series Digital Phosphor Oscilloscopes 07-070-00 0707000 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most common operations. Turn INTENSITY
More informationPrecautions About the Product... 4 Package Overview Product Overview... 6 Start Your Installation... 8
2 Table of Contents Usage Notice Precautions... 3 Introduction About the Product... 4 Package Overview... 5 Installation Product Overview... 6 Start Your Installation... 8 User Controls User Control Overview...
More informationQuick Start ATOMIC FORCE MICROSCOPE West Campus Imaging Core
Quick Start ATOMIC FORCE MICROSCOPE West Campus Imaging Core 1 Turn On the laser power 2 Open enclosure: - lift the door latch and open the enclosure door. 3 2 1 1.Unlock scanner: Lift the lever to the
More informationHow to Optimize Ad-Detective
How to Optimize Ad-Detective Ad-Detective technology is based upon black level detection. There are several important criteria to consider: 1. Does the video have black frames to detect? Are there any
More informationABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer
ABB MEASUREMENT & ANALYTICS MB3000 The most reliable FT-IR laboratory analyzer 2 M B 3 0 0 0 T H E M O S T R E L I A B L E F T- I R L A B O R ATO R Y A N A LY Z E R Measurement made easy The MB3000 FT-IR
More informationOscilloscope Guide Tektronix TDS3034B & TDS3052B
Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic
More informationOWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON
OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON CH+ CH- TABLE OF CONTENTS SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS and FEATURES ACCESSORIES and LOADING BATTERIES REMOTE CONTROL UNIT FRONT PANEL and REAR
More informationTMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer
TECH TIP # 70 TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer Introduction TR0070.0 Successful acquisition of quantitative tandem mass tag (TMT*) data with the Thermo Scientific LTQ-Orbitrap
More information1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5
1. Get support 1 2. Attention 1 3. Safety Caution 1 4. Applications 1 5. View Cameras on Screen (ex. HD TV or PC monitor) 3 Change Time Zone 5 6. Installation Guide for ONWOTE Cameras 6 7. View Cameras
More informationPart 1 Basic Operation
This product is a designed for video surveillance video encode and record, it include H.264 video Compression, large HDD storage, network, embedded Linux operate system and other advanced electronic technology,
More informationKratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions
Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions Note: Enter your complete name, CMRF user code, and date into the record book. You must have previously filled out a project information
More informationGBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver. Title Slide
GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver Title Slide Narrator: Although the use of a data table illustrates how we can apply Monte Carlo simulation to a decision
More informationUniversity of Minnesota College of Science and Engineering Characterization Facility Ganesha SAXSLAB User manual
University of Minnesota College of Science and Engineering Characterization Facility Ganesha SAXSLAB User manual # Section Pg # 1 Planning a SAXS experiment 1 2 Initial Setup 2 3 Sample mounting and loading
More informationINCA ENERGY EDS TRAINING. System Block Diagram. INCA Energy Software. Xiang Yang EM SMU. Navigators. Point & ID Navigator.
INCA ENERGY EDS TRAINING Xiang Yang EM Center @ SMU System Block Diagram INCA Energy Software Navigators Point & ID Navigator Data tree 1 Spectrum Export Bitmap TIFF JPEG Metafile EMSA ISIS Optimum Conditions
More informationCAEN Tools for Discovery
Viareggio March 28, 2011 Introduction: what is the SiPM? The Silicon PhotoMultiplier (SiPM) consists of a high density (up to ~10 3 /mm 2 ) matrix of diodes connected in parallel on a common Si substrate.
More informationGetting started with
Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial premises OVERVIEW: The OWL Intuition-e electricity monitoring system comprises of three
More informationMestReNova Manual for Chem 201/202. October, 2015.
1. Introduction to 1-D NMR Data Processing with MestReNova The MestReNova program can do all of the routine NMR data processing needed for Chem 201 and 202 and will be available through the Reed downloads
More informationASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams
ASE 369 K Measurements and Instrumentation LAB #9: Impulse-Force Hammer; Vibration of Beams Equipment: Dell Optiplex computer with National Instruments PCI-MIO-16E-4 data-acquisition board and the Virtual
More informationWQ Series Water Quality Bench top Meters
USER GUIDE WQ Series Water Quality Bench top Meters Model WQ500 ph, ORP and Temperature Model WQ510 ph, ORP, Conductivity, TDS, Salinity, & Temperature Model WQ530 ph, ORP, Conductivity, TDS, Salinity,
More informationGeChic Corporation 13F.-4, No.367, Gongyi Road, West District, Taichung City 403 Taiwan (R.O.C.) Customer Service:
GeChic Corporation 13F.-4, No.367, Gongyi Road, West District, Taichung City 403 Taiwan (R.O.C.) Customer Service: +886-4-23198080 Monitor for Laptop 1301 User Manual Table of Contents Chapter 1 Content
More informationLiquid Chromatography- Mass Spectrometer Manual
Liquid Chromatography- Mass Spectrometer Manual Joshua Willis, Elizabeth Sattely Department of Chemical Engineering Stanford University November 6, 2014 Abstract This manual will explain the LC/MS, its
More informationPracticum 3, Fall 2010
A. F. Miller 2010 T1 Measurement 1 Practicum 3, Fall 2010 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z magnetization
More informationBitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.
BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features
More informationUSER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)
USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade) This Manual is revisable without further notice Contents CONTENTS ------------------------------------------------------------------- 1
More informationCHECKLIST FOR VERIOS OPERATION 1. GENERAL The SEM lab is used assuming "operating room" cleanliness, i.e., the SEM lab is a high visibility lab and
CHECKLIST FOR VERIOS OPERATION 1. GENERAL The SEM lab is used assuming "operating room" cleanliness, i.e., the SEM lab is a high visibility lab and must be kept clean and neat so clean up behind yourself
More informationHow-to Setup Motion Detection on a Dahua DVR/NVR
How-to Setup Motion Detection on a Dahua DVR/NVR Motion detection allows you to set up your cameras to record ONLY when an event (motion) triggers (is detected) the DVR/NVR to begin recording and stops
More informationThe PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.
PHI VersaProbe Scanning XPS System I. Overview The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction. PHI Summitt
More informationHigh Performance (Gold Plus) Spliceable Tape Feeder Part Number: Part Number: Revision 3 Jun 2008 No.
8mm High Performance (Gold Plus) Spliceable Tape Feeder Part Number: 50934707 12mm High Performance (Gold Plus) Spliceable Tape Feeder Part Number: 50934807 Revision 3 Jun 2008 No. 0930D-E010 i Table
More informationFlat-Bed Module Recorders
Flat-Bed Module Recorders Model No. 08376-50 08376-55 08376-60 0115-0192 4/28/00 Table of Contents Introduction...3 Power Requirements...3 Chart Paper Installation...3 Pen Installation...5 Grounding...5
More informationJAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit
JAMAR TRAX RD The TRAX RD is an automatic traffic recorder designed and built by JAMAR Technologies, Inc. Since the unit is a Raw Data unit, it records a time stamp of every sensor hit that occurs during
More informationModel#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04
Model#: IN-MDRI3MF 3MP Indoor Mini Dome with Basic WDR, Fixed lens Hardware User Manual (PoE) Ver. 2013/02/04 Table of Contents 0. Precautions 3 1. Introduction 4 Package Contents... 4 Features and Benefits...
More informationTechNote: MuraTool CA: 1 2/9/00. Figure 1: High contrast fringe ring mura on a microdisplay
Mura: The Japanese word for blemish has been widely adopted by the display industry to describe almost all irregular luminosity variation defects in liquid crystal displays. Mura defects are caused by
More informationInstruction for Locking Tuner s Carriage(s) before Shipping
Instruction for Locking Tuner s Carriage(s) before Shipping Step 1. Configure tuner properties and verify connection From ATS block diagram view, double click on the tuner that needs to be locked. The
More informationTV Setup and Troubleshooting
Service Menu TV Setup and Troubleshooting E-TRe & E-TRxe The following procedure will guide you through the Channel Scan of the Embedded E-TRe and E-TRxe treadmills. Step 1 Start on the default screen
More informationABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC
ABB MEASUREMENT & ANALYTICS MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC 2 M B 3 6 0 0 T H E M O S T R E L I A B L E F T- N I R L A B O R ATO R Y A N A LY Z E R D E S I G N E
More informationLUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY
Standard Operating Procedure for the Bruker X8 APEX II Single-Crystal X- Ray Diffractometer Contact Manager: Dr. Cassie Ward ward@wayne.edu Office room 061 Chemistry (313) 577-2587 LIC Lab: (313) 577-0518
More informationT5-RM HD MITS. User Manual. 3-Dmed LEARNING THROUGH SIMULATION
T5-RM HD MITS User Manual 3-Dmed LEARNING THROUGH SIMULATION T5-RM HD Minimally Invasive Training System Thank you for purchasing the T5-RM HD MITS from 3-Dmed Each has been fully tested prior to shipment
More informationSystem Requirements SA0314 Spectrum analyzer:
System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into
More informationHV/PHA Adjustment (PB) Part
HV/PHA Adjustment (PB) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 2. HV/PHA adjustment sequence...7 3. How to use this Part...9 HV/PHA Adjustment (PB) Part i
More information28 4K LED monitor. User Manual M284K
28 4K LED monitor User Manual M284K CONTENTS Safety Information... 2 What s included..... 4 Getting Started....... 8 Troubleshooting.... 14 Specification.... 15 2 of 15 SAFETY INFORMATION Read these instructions
More informationCN Remove the scanner assembly (X476 and X576 models) and all doors/covers.
CN598-67045 www.hp.com/support IMPORTANT: Ensure the product firmware is upgraded to at least version 1336MR before performing this repair procedure. If the firmware upgrade cannot be completed, contact
More informationHow to Build A Table of Authorities in Word * By: Morgan Otway
How to Build A Table of Authorities in Word * By: Morgan Otway Overview: A Table of Authorities (TOA) is a list of all of the sources cited in a legal document that notes the page numbers on which each
More informationCoyote popup display set up instructions
Coyote popup display set up instructions Frame 1 2 3 Prepare frame for assembly by locating the purple hooks on top of the frame. Stretch frame to size, snapping magnetic locking arms together. Attach
More informationJS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA
JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA The JS007WQK is loaded with userfriendly features and is ideal for use in heavy duty vehicles.
More informationSpectra/Chrom Chart Recorder from Spectrum Chromatography
Spectra/Chrom Chart Recorder from Spectrum Chromatography D20140 180296 Copyright 1996 by Spectrum Chromatography PO Box 672026 Houston, TX 77267-2026 Phone: (281) 443-2900 (800) 459-9700 (US & Canada)
More informationCompact live fiber identifier with integrated optical power meter
FI-Series Live Fiber Identifier Compact live fiber identifier with integrated optical power meter User Manual ZP-PKG-0535 REV 1 Notice Copyright Trademarks Every effort was made to ensure that the information
More informationScan-Light Supplement. Fitting instructions and hardware details For Mitsubishi MH105AG and MH216CG scanners
Scan-Light Supplement Fitting instructions and hardware details For Mitsubishi MH105AG and MH216CG scanners Contents Contents Fitting instructions and hardware details... 1 For Mitsubishi MH105AG and MH216CG
More informationOSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD
EXECUTIVE / MiniDome OSD USERS MANUAL USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD MotoSAT Corporation Created April 22, 2003 1-800-247-7486 CONGRATULATIONS! on your purchase of your
More informationLet s build the EdCrane Difficulty:
EdBuild Let s build the EdCrane Difficulty: The EdCrane EdBuild by Microbric Education is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. EdBuild the EdCrane The EdCrane
More informationAPA Style Page Formatting Instructions Microsoft Word Windows Version. Adjust all margins to 1 inch on each side, page in Portrait orientation
APA Style Page Formatting Instructions Microsoft Word Windows Version PART 1 GENERAL FORMATTING AND COVER PAGE Adjust all margins to 1 inch on each side, page in Portrait orientation 1. Click on the Page
More informationPLL1920M LED LCD Monitor
PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6
More information2.4 Scheduled Events Schedule Recording. 1. In Multicam, click on the Schedule icon. 2. Select Schedule Edit.
2.4 Scheduled Events 2.4.1 Schedule Recording 2. Select Schedule Edit. 3. Setup basic recording schedule as follows: a. Select cameras which schedule is to be applied. b. Select Round-the-clock or Motion
More informationAFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)
AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) 1. Log into the Log Usage system on the SMIF web site 2. Open Nanoscope 6.14r1 software by double clicking on the Nanoscope 6.14r1 desktop
More informationOZONESONDE FLIGHT PREPARATIONS
OZONESONDE FLIGHT PREPARATIONS 2 Table of Contents Notes... 3 A week before flight preparations... 4 Changing the sensor solution... 4 Measuring background current... 5 Day of flight preparation... 7 Closing
More informationThe Grey Nomad s Guide to Satellite Dish Setup Procedures.
The Grey Nomad s Guide to Satellite Dish Setup Procedures. Compiled and written by Ronald H Tew of The Wandering Tews Issue 18, 5 th January 2014. Web site: www.wanderingtews.com 1 About this Document.
More informationBasic 13 C Acquisition and Processing 4
Chapter Basic 13 C Acquisition and Processing 4 Goto Introduction 4.1 This chapter describes the acquisition and processing of a 13 C spectrum acquired with a simple one-pulse sequence with and without
More informationFACSAria I Standard Operation Protocol Basic Operation
FACSAria I Standard Operation Protocol Basic Operation 1. Checking Lasers Status a. Please check the ON / OFF of the lasers. Sufficient time (~30 minutes) need to be given to allow the laser(s) to warm
More informationGetting started with
PART NO. CMA11 3 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted
More informationIndiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope
Indiana Center for Biological Microscopy Zeiss LSM-510 510-UV Confocal Microscope Microscope and the Attached Accessories Transmission Detector Halogen Lamp House Condenser Eyepiece Stage Scanning and
More informationTT AFM LongBeach Procedures and Protocols V2.1
TT AFM LongBeach Procedures and Protocols V2.1 1. Startup Procedure 1. Turn on PC: Allow to boot to Windows. Turn on monitor. Password is afm 2. Turn on second PC that controls the video camera. 3. Turn
More informationStep 1. 1x NXT Ultrasonic Sensor
Start with the build completed in Lesson 3 of the TETRIX Getting Started Guide. Step 1 involves removing an element from the model. This element will be reattached later. Parts to be Removed Step 1 1x
More informationHCImage Live Getting Started Guide
HCImage Live Getting Started Guide Release 4.4 December 2017 This guide, as well as the software described in it, is covered under license agreement and may be used or copied only in accordance with the
More informationDS-575W User's Guide
DS-575W User's Guide Contents DS-575W User's Guide... 7 Scanner Basics... 8 Scanner Parts Locations... 8 Scanner Parts... 8 Scanner Buttons and Lights... 11 User Replaceable Epson Scanner Parts and Accessories...
More informationMIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003
MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition
More informationGuide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley
Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley Contents Getting Started Setting Up the Sound File Noise Removal Finding All the Bat Calls Call Analysis
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PARTS REQUIRED Parts in the box Single monitor Dual monitor M2 M8 M/Flex + (package contents will depend on configuration ordered) Tools required for installation 6.0 mm Hex Key
More informationUniversal Mode. Survey Settings. The Universal Toolbar. First Run - Initial Configuration via the Setup Button
Universal Mode The Universal Toolbar The Universal Toolbar is the unified (and preferred) method of operating Revolution. From within the Universal Toobar, all functionality of the other 3 modes of Revolution
More information7. Image transmission functions
This unit comes with a function for transmitting still images from the host computer to the unit via LAN and a function for importing still images from the unit into the host computer. The image transmission
More informationData Acquisition Using LabVIEW
Experiment-0 Data Acquisition Using LabVIEW Introduction The objectives of this experiment are to become acquainted with using computer-conrolled instrumentation for data acquisition. LabVIEW, a program
More informationHRXRD Analysis of Epitaxial Thin Films
HRXRD Analysis of Epitaxial Thin Films on the Rigaku Smartlab Multipurpose Diffractometer Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT For assistance in the X-ray lab, contact
More informationUser manual for: Digital 3D viewer for panel mount Model D50-x
de Wijs apparatenbouw Vleugelboot 68, 3991CL, Houten the Netherlands Tel. +31 (0)30-6364928 Fax. +31 (0)30-6361723 e-mail: info@dewijs-3d.com Website: www.dewijs-3d.com User manual for: Digital 3D viewer
More information#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)
BIOPAC Systems, Inc. 42 Aero Camino Goleta, Ca 93117 Ph (805)685-0066 Fax (805)685-0067 www.biopac.com info@biopac.com #PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis) The Biopac
More informationCable System Installation Guide
Overview Cable System Installation Guide 5/19/2008 Our recommended approach for the installation of your Circle Graphics Cable Systems on the panels in your market is to install the fixed hardware (namely
More informationToughsat Flyaway Users Manual
Toughsat Flyaway Users Manual TOUGHSAT FLYAWAY USERS MANUAL V.1.6 September 2012 Important warning regarding your TOUGHSAT System All power to the system (controller, modem, external network devices) MUST
More information