DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

Size: px
Start display at page:

Download "DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES"

Transcription

1 DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES CommScope Instruction Sheet Issue 10, February 2004 Material ID General The Digital Distributing Frame (DDF) is a 75-ohm frame system that serves as an equal level cross-connect point for signals conforming to the DS3 (44.76 Mb/s), CEPT-1 (2.048 Mb/s), CEPT-2 (8.448 Mb/s), CEPT-3 ( Mb/s), CEPT-4 ( Mb/s), and STM-1 ( Mb/s) signal formats. The modules allow access to all equipment terminated at the frame and provide a flexible cross-connect between two Network Elements. Equipment Description The DDF system consists of individual DDF modules mounted in a panel. There are three types of DDF modules: the Rear/Front DDF Dual Monitor (R/F-DDF-DM), the DDF Performance Module (DDF-PM), and the Rear/Rear DDF Dual Monitor (R/R-DDF-DM). The DDF-DM modules have two protected monitor-level ( 20 db) jacks to provide nonservice interrupt monitoring of all circuits. The DDF-PM modules have a single protected monitor level jack. The Rear/Front DDF Dual Monitor (R/F-DDF-DM) module, shown in Figure 1, is equipped with six BNC connectors. Four BNC connectors are located on the front of the module: MON-O (Monitor Out), MON-I (Monitor In), OUT, and IN. Two BNC connectors are located on the rear of the module: TX and RX (Out transmit and In receive, respectively). MON-O MON-I 0.75" (19 mm) OUT 3.6" (92 mm) 0.8" (21 mm) TX Out (transmit) IN 0.75" (19 mm) 1" (25 mm) RX 0.62" (16 mm) Front Side Rear Fig01DDF-DM.wmf Figure 1. Digital Distribution Frame Dual Monitor (DDF-DM) The Rear/Rear Dual Monitor (R/R-DDF-DM) module (shown in Figure 2) is equipped with six BNC connectors. Four BNC connectors are included on the front of the module: OUT, IN, TX (Out transmit), and RX (In receive). This module is snapped into panels from the rear for rear cross-connect applications. The DDF Performance Module (DDF-PM) is equipped with five BNC connectors. Three BNC connectors are located on the front of the module: MON, OUT, and IN. Two BNC connectors are located on the rear of the module: TX and RX (Out transmit and In receive, respectively) CommScope, Inc. All Rights Reserved Printed in U.S.A. Page 1

2 Instruction Sheet OUT IN MON-O TX MON-I RX Fig02RR-DDF-DM.wmf Figure 2. Rear/Rear Digital Distribution Frame Dual Monitor (R/R-DDF-DM) Module The R/F panels are available in both 32-module and 24-module arrangements and mount horizontally in either a 23-inch (600 mm) wide bay frame (32-module version) or a 19-inch (500 mm) wide bay frame (24 module version). The 24-module Rear/Rear panel includes adapter brackets for mounting in a 23-inch (600 mm) wide bay frame. The 32-module R/F-DDF panel, shown in Figure 3, mounts horizontally in a 23-inch (600 mm) wide network bay frame. A 7-foot (2.1 m) bay frame can accommodate up to 12 panels for a total of 384 circuits, or if the optional horizontal trough is used, up to nine panels for a total of 288 circuits. 22.2" (566 mm) 6.8" (175 mm) Figure 3. DDF 32-Module Panel With Optional Horizontal Trough Fig03DDF 32-Mod.wmf Page 2

3 Issue 10, February 2004 The 24-Module R/F DDF panel, shown in Figure 4, mounts horizontally in a 19-inch (500 mm) wide network bay frame. A 7-foot (2.1 m) bay frame can accommodate up to 12 panels for a total of 288 circuits, or if the optional horizontal trough is used, up to nine panels for a total of 216 circuits. Figure 4. DDF 24-Module Panel With Optional Horizontal Trough Fig04DDF 24-Mod.wmf The 24-module R/R DDF panel shown in Figure 5 mounts horizontally in a 19-inch (500 mm) wide network bay frame; or, if the supplied adapter brackets are used in a 23-inch (600 mm) wide network bay frame. A 7-foot (2.1 mm) bay frame can accomodate up to 15 panels for a total of 360 circuits. 18.3" (465 mm) 4.0" (101.6 mm) Fig05 24-Mod RR DDF.wmf Figure Module R/R DDF Panel The DDF system may be configured for front or rear cross-connect and interconnect applications. A complete line of network bay frames, framework hardware, and patch and test cords are available to support installation, cable management, and operations. Page 3

4 Instruction Sheet Features of the DDF include the following: Compatible with DS3, CEPT-1, CEPT-2, CEPT-3, CEPT-4, and STM-1 signal rates. BNC connectors are equipped with a locking mechanism for both the patch cords (in cross-connect arrangements). Recommended front cross-connect arrangement allows easy access for patching around faulty equipment. Ground-isolated modules (no separate grounding required at the DDF). Test cords are equipped with easy to use, push-on BNC connectors. Patch cords are equipped with locking BNC connectors. Standard BNC connectors are available from a variety of sources for any coaxial cable type. Two standard panel sizes are available, while other panel sizes are available upon request. R/F Panels include a heavy-duty hinge incorporated into the bottom, which allows it to swing forward for easy access to the rear of the panel. This feature is especially useful when mounting in a cabinet. How to Contact Us To find out more about Carrier Apparatus products, visit us on the web at: For technical assistance regarding Carrier Apparatus products: contact your local CommScope account representative or CommScope technical support at Report any missing or damaged parts to CommScope customer service in Omaha, Nebraska, at References Digital Distributing Frame (DDF) System Reference Guide More product documentation for Digital Distributing Frames is available at the following CommScope web address: click Support & Documentation. Tools Required Flat-blade 0.2-inch (5 mm) wide, 6-inch (152 mm) long screwdriver Page 4

5 Issue 10, February 2004 Ordering Information Table 1: DDF Panel and Module Ordering Information Apparatus Code Material ID Description Patch and Test Cords DDF-WCA1-02-PBNC Test Cord, single push-on BNC to BNC, 6 feet 6 inches (2 m) Long DDF-WCA1-03-PBNC Test Cord, single push-on BNC to BNC, 9 feet 10 inches (3 m) Long DDF-PC1A-00-BNC Locking U-link Cord, single BNC to BNC, 4 inches (100 mm) Long DDF-PC1A-01-BNC Patch Cord, single BNC to BNC, 3 feet 2 inches (1 m) Long DDF-PC1A-02-BNC Patch Cord, single BNC to BNC, 6 feet 6 inches (2 m) Long DDF-PC1A-03-BNC Patch Cord, single BNC to BNC, 9 feet 10 inches (3 m) Long DDF-PC1A-04-BNC Patch Cord, single BNC to BNC, 13 feet 1 inches (4 m) Long DDF-PC1A-06-BNC Patch Cord, single BNC to BNC, 19 feet 7 inches (6 m) Long DDF-PC2A-01-BNC Patch Cord, duplex BNC to BNC, 3 feet 2 inches (1 m) Long DDF-PC2A-02-BNC Patch Cord, duplex BNC to BNC, 6 feet 6 inches (2 m) Long DDF-PC2A-03-BNC Patch Cord, duplex BNC to BNC, 9 feet 10 inches (3 m) Long DDF-PC2A-04-BNC Patch Cord, duplex BNC to BNC, 13 feet 1 inches (4 m) Long DDF-PC2A-06-BNC Patch Cord, duplex BNC to BNC, 19 feet 7 inches (6 m) Long Modules DDF-1B Single DDF-PM assembly DDF-1B Package of 24 DDF-PM modules DDF-DM-1B Single DDF-DM assembly. Rear/Front cabled DDF-DM-1B Package of 24 DDF-DM Rear/Front cabled modules DDF-DM-1B Package of 32 DDF-DM Rear/Front cabled modules DDF-DM-NE-1B Single DDF-DM assembly. Rear/Rear cabled. DDF-DM-NE-1B Package of 24 DDF-DM Rear/Rear cabled modules Panels DDF-1B500-24/4BNC Hinged, cross-connect/interconnect panel equipped with 24 single monitor modules for 19-inch (500 mm) bay and cabinets. DDF-1B600-32/EMP Hinged, empty panel that can accommodate up to 32 modules, for 23- inch (600 mm) bay. DDF-1B600-32/4BNC Hinged, cross-connect/interconnect panel equipped with 32 single monitor modules for 23-inch (600 mm) bay. DDF-1B600-SHLF Horizontal trough for use with 23-inch (600 mm) panel, includes circuit identification label. DDF-1B500-SHLF Horizontal trough for use with 19-inch (500 mm) panel, includes circuit identification label. DDF-DM-1A600-32/6BNC Hinged, cross-connect/interconnect panel equipped with 32 dual monitor R/F modules for 23-inch (600 mm) bay. DDF-DM-1A600-32/6EMP Hinged, empty panel that can accomodate up to 32 modules, for 23-inch (600 mm) bay. DDF-DM-1A500-24/5BNC Hinged cross-connect/interconnect panel equipped with 24 dual monitor modules for 19 inch (500 mm) bay. Page 5

6 Instruction Sheet Apparatus Code Material ID Description DDF-DM-NE-1A500-24/ 4EMP DDF-DM-NE-1A500-24/ 4BNC Empty panel for rear/rear applications that can accomodate up to 24 modules for 19-inch (500 mm) or 23-inch (600 mm) bays Cross-connect/interconnect panel equipped with 24 dual monitor R/R modules for 19-inch (500 mm) or 23-inch (600 mm) bays. Panel Installation Configurations AD-8C Group 5 AD8C50050G5 For Rear/Rear Applications: 7-foot (21 mm) high, 23-inch (600 mm) wide, unequal flange, Network Bay Frame with 5-inch guard rail cover on open duct side. AD-8C Group 1 AD8C50150G1 For All Rear/Front Applications: 7-foot (2.1 m) high, 23-inch (600 mm) wide, unequal flange, Network Bay Frame with 5-inch guard rail cover on closed duct side. ED-6C Group 12 ED6C15730G12 One 8x8 inch lower express trough and extension bracket ED-6C Group 16 ED6C15730G16 One 8x10 inch upper horizontal express trough ED-6C Group 36 ED6C15730G36 Single full vertical trough. Includes label set, label holder, cover, and mounting hardware. ED-6C Group 37 ED6C15730G37 Single half vertical trough. Includes label set, label holder, cover, and mounting hardware. ED-6C Group 51 ED6C15730G51 5-inch bay spacing hardware ED-6C Group 5 ED6C15731G5 For Rear/Front Cross-Connect Application Only: Bay hardware. Includes upper and lower express troughs, six rear cable brackets, bay spacing hardware, guard rail extension kit, rear cable cover kit, two jumper retainers, and mounting hardware. ED-6C Group 6 ED6C15731G6 For Rear/Front Interconnect Application Only: Interconnect bay hardware. Includes six rear cable brackets, rear cable cover kit, and mounting hardware. ED-6C Group 7 ED6C15731G7 For Cross-Connect Application Only: Full vertical troughs. Includes 12 full vertical troughs, 12 label sets, 24 label holders and covers, and mounting hardware. ED-6C Group 8 ED6C15731G8 For Cross-Connect Application Only: Half vertical troughs. Includes 12 half vertical troughs, 12 label sets, 24 label holders and covers, and mounting hardware. Page 6

7 Issue 10, February 2004 PANEL INSTALLATION FOR R/F PANELS ON 5-INCH (127 mm) CENTERS Rear/Front cabled panels should be installed on 5-inch (127 mm) centers if the optional horizontal troughs are not used, as shown in Figure 6. Panels should be installed on 7-inch (178 mm) centers if the optional horizontal troughs are used as shown in Figure 7 on page Mount the framework hardware and panels in the locations shown in Figure 6. Note: Figure 6 shows an upper and lower express trough and vertical trough used in Front-Cross Connect applications only. Disregard this information if using Interconnect application. Panels are mounted on top of the vertical troughs and the upper and lower express troughs are used to route and manage cross-connect cords running between adjacent bays. 2. Route Network Element cabling into the bay frame from either the top or bottom (depending upon site requirements). Fig06 installation for 5-inch panels.wmf Hole #73 12 Upper express trough 14" (356 mm) Hole #67 11" (279 mm) Hole #69 11 Hole #62 10" (254 mm) Hole #57 Hole #52 Hole #47 Hole #59 10" (254 mm) Hole # Hole #42 Hole #37 10" (254 mm) Hole #39 5 H ole #32 10" (254 mm) 4 3 H ole #27 H ole #22 Hole #29 10" (254 mm) 2 H ole #17 Hole #19 REAR CABLE BRACKET 1 H ole #12 Vertical trough Lower express trough H ole #7 11" (279 mm) H ole #8 H ole #6 10" (254 mm) Rear cable enclosure Rear cable cover Front view 4" (102 mm) Rear view Figure 6. Panel Installation for Panels on 5-Inch (127 mm) Centers Page 7

8 Instruction Sheet PANEL INSTALLATION FOR R/F PANELS ON 7-INCH (178 mm) CENTERS Rear/Front cabled panels should be installed on 7-inch (178 mm) centers if optional horizontal troughs are used as shown in Figure 7. Panels should be installed on 5-inch (127 mm) centers if optional horizontal troughs are not used, as shown in Figure Mount the framework hardware and panels in the locations shown in Figure 7. Note: Figure 7 shows an upper and lower express trough and vertical trough used in Front-Cross Connect applications only. Disregard this information if using Interconnect application. Panels are mounted on top of the vertical troughs and the upper and lower express troughs are used to route and manage cross-connect cords running between adjacent bays. 2. Route Network Element cabling into the bay frame from either the top or bottom (depending upon site requirements). Fig07 installation for 7-inch panels.wmf Hole #73 Upper express trough 11" (279 mm) 15" (381 mm) 9 Hole #69 H ole #65 8 H ole #62 14" (356 mm) 7 H ole #55 H ole #51 6 H ole #48 14" (356 mm) 5 H ole #41 H ole #37 4 H ole #34 14" (356 mm) 3 H ole #27 H ole #23 2 HOLE #20 Rear cable bracket 1 HOLE #13 H ole #7 H ole #8 H ole #6 Rear cable enclosure Lower express trough 11" (279 mm) 10" (254 mm) Rear cable cover Front view 4" (102 mm) Rear view Figure 7. Panel Installation for Panels on 7-Inch (178 mm) Centers Page 8

9 Issue 10, February 2004 WATERFALL CABLING FOR REAR/FRONT CABLED PANELS Cabling for equipment terminated on Panels 1 through 12 uses the waterfall cabling method. A DDF system comprised of 12 panels and using waterfall cabling is shown in Figure Cable the equipment terminated on Panel Position No. 1 in the left most slot (as viewed from rear of bay frame) of the rear cable brackets. Cabling for other panels are routed in their respective bracket slots, continuing from the left. As an example, cabling for Panel No. 2 is routed in the second slot from the left. This cabling scheme continues until cabling for Panel No. 12 is routed in the right-most slot. 2. Secure cabling to the rear cabling brackets with cable ties or lacing material, depending on local practices. 3. Route cables to the bottom of the panel and spread across the rear of the panel. 4. Install BNC connectors and connect cables as follows: Transmit from N.E. No. 1 to upper BNC port on rear of module. Receive from N.E. No. 1 to lower BNC port on rear of module. Equipment cabling Panel # 12 Panel # 11 Panel # 10 Panel # 9 Panel # 8 N.E. # 1 -Transmit Panel # 7 Panel # 6 Panel # 5 Module (Rear View) N.E. # 1 - Receive Panel # 4 Panel # 3 Panel # 2 Rear cable bracket Panel # 1 DDF Panel Rear cable enclosure Rear cable cover Rear view Fig08 waterfall cabling for rear-front panels.wmf Figure 8. Waterfall Cabling for Rear/Front Cabled Panels Page 9

10 Instruction Sheet PANEL INSTALLATION FOR R/R PANELS ON 4-INCH (102 mm) CENTERS Panels should be installed on 4-inch (102 mm) centers as shown in Figure Mount the framework hardware and panels in the locations shown in Figure 9. Note: The upper and lower express troughs are used to route and manage cross-connect cords running between adjacent bays. 2. Route Network Element cabling into the bay frame from either the top or bottom (depending upon site requirements). Fig09 insatallation for 4-inch RR panels.wmf Upper Express Trough (15) 4-Inch Panels (Typical) Towel Bracket Vertical Trough " ( mm) 4.00" ( mm) 1 Label Holder 13.00" ( mm) 13.00" ( mm) Lower Express Trough Front View Rear View Figure 9. Panel Installation for R/R Panels on 4-Inch (102 mm) Centers Page 10

11 Issue 10, February 2004 CONNECTING R/F DDF MODULES FOR FRONT CROSS-CONNECT APPLICATION The front cross-connect configuration requires two DDF modules to complete a circuit. The module allows easy access to jumpers for circuit rearrangements during installation of new network elements and/or restorations. The circuit may be monitored in both directions of transmission. The connections at the module and a functional schematic of the application are shown in Figure 10. Monitor N.E. #1 (Transmit) N.E. #2 (Receive) N.E. #1 (Receive) N.E. #2 (Transmit) Fig10 connecting RF DDF module.wmf N.E. #1 DDF-DM Monitor Transmit (N.E. #1) Receive (N.E. #1) N.E. #2 Monitor Jumpers DDF-DM Transmit (N.E. #2) Receive (N.E. #2) Figure 10. Connecting R/F DDF Module for Front Cross-Connect Application Page 11

12 Instruction Sheet CONNECTING R/F DDF MODULE FOR INTERCONNECT APPLICATION The interconnect application requires one Dual Monitor module to complete a circuit. This configuration is as flexible as the cross-connect application. The circuit may be monitored in both directions of transmission. The connections at the module and a functional schematic of the application are shown in Figure 11 for the Rear/ Front cabled module. Monitor N.E. #1 (Transmit) Test cord (Push-on type) N.E. #2 (Receive) N.E. #1 (Receive) N.E. #2 (Transmit) Fig11 DDF module for interconnect.wmf N.E. #1 DDF-DM Monitor (Out) Monitor (In) N.E. #2 Dual monitor Figure 11. Connecting R/F DDF Module for Interconnect Application Page 12

13 Issue 10, February 2004 CONNECTING R/F DDF MODULES FOR REAR CROSS-CONNECT APPLICATION The rear cross-connect configuration requires two DDF modules to complete a circuit. The module allows easy access to jumpers for circuit rearrangements during installation of new network elements and/or restorations. The circuit may be monitored in both directions of transmission. The connections at the module and a functional schematic of the application are shown in Figure 12. N.E. #2 (Receive) N.E. #2 (Transmit) N.E. #1 (Transmit) N.E. #1 (Receive) Fig12 DDF module for rear cross-connect.wmf Rear/Rear DDF-DM Monitor N.E. #1 (Receive) Jumpers N.E. #1 N.E. #1 (Transmit) Rear/Rear DDF-DM Monitor N.E. #2 (Transmit) N.E. #2 (Receive) N.E. #2 Figure 12. Connecting R/F DDF Module for Rear Cross-Connect Application Page 13

14 Instruction Sheet CONNECTING R/R DDF MODULE FOR INTERCONNECT APPLICATION The interconnect application requires one Dual Monitor module to complete a circuit. This configuration is as flexible as the cross-connect application. The circuit may be monitored in both directions of transmission. The connections at the module and a functional schematic of the application are shown in Figure 13 for the Rear/ Front cabled module. N.E. #2 (Receive) N.E. #2 (Transmit) N.E. #1 (Transmit) N.E. #1 (Receive) Fig13 RR DDF module for interconnect.wmf Rear/Rear DDF-DM N.E. #2 Monitor N.E. #1 Rear/Rear dual monitor Figure 13. Connecting R/R DDF Module for Interconnect Application Page 14

15 Issue 10, February 2004 INSTALLING AND REMOVING THE DDF MODULE Installing DDF Module in Panel 1. Position the module at an angle to the panel so that the bottom of the module is close to the tab molded into panel. Place bottom of module onto tab, as shown in Figure With the bottom of the module on the tab, swing the module up until it contacts the panel and continue pushing until it locks into place. The module is now ready to attach patch cords. Removing DDF Module From Panel 1. Swing the panel forward to allow access to the rear of module (Rear/Front panels only). 2. Using a flat screwdriver or other blunt tool, press the latch at the top of the module. 3. Swing the module down and lift it out of panel. Fig14 installing and removing DDF module.wmf Push module forward until it snaps in place Latch on module Swing panel forward to gain access to rear of module Press latch on module Position module at an angle on tab Tab in panel Swing module down and lift out Installing DDF module Removing DDF module Figure 14. Installing and Removing the DDF Module Page 15

16 Instruction Sheet PATCH AND TEST CORDS There are four types of cords used with the DDF: Single push-on BNC BNC test cord Locking U-link BNC BNC patch cord Single BNC BNC patch cord Duplex BNC BNC patch cord The duplex BNC BNC patch cords are constructed with one white coaxial cable and one blue coaxial cable encased in a white outer jacket. The different colored coaxial cables allow easy identification of Transmit and Receive and help to maintain circuit integrity from one panel to another. The patch cords and test cords are shown in Figure 15. Strain relief Push-on BNC Length Single Push-On BNC-BNC Test Cord Strain relief Locking BNC 100 mm Locking U-Link Cord Strain relief Locking BNC Length Single BNC-BNC Patch Cord Blue coaxial cable White outer jacket Locking BNC Strain relief White coaxial cable Length Duple/BNC-BNC Patch Cord Fig15 patch and test cords.wmf Figure 15. Patch and Test Cords Page 16

Broadband Connectivity System II

Broadband Connectivity System II User Manual Applys to: :: 010-3232-0001 :: 010-3224-0001 :: 010-3201-0407 :: 010-3201-0401 :: 010-3201-0410 :: 710-3201-0002 :: 710-3201-0005 :: 710-3201-1001-U :: 710-3201-1002-U :: 710-3201-2001-U ::

More information

BCS 4R DSX-3 Connectivity System. Models , , and User Manual

BCS 4R DSX-3 Connectivity System. Models , , and User Manual BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and

More information

RACKS, ENCLOSURES AND CABLE MANAGEMENT

RACKS, ENCLOSURES AND CABLE MANAGEMENT and RS3 RACK SYSTEM (pages 6.2 6.3) RS RACK SYSTEM (pages 6.4 6.5) EXTENDED DEPTH RS RACK SYSTEM (page 6.5) Vertical Side Rail Capacity Cable Manager Covers Accessories 117mm x 152mm (4.6 in. x 6.0 in.)

More information

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs) USER MANUAL MODEL 460RC Rack-Mounted G.70 Coax to Twisted Pair Adapters (BALUNs) An ISO-900 Certified Company Part # 07M460RC-A Doc. #0908UA Revised //98 SALES OFFICE (0) 975-000 TECHNICAL SUPPORT (0)

More information

6000 Series Patch Panel Terminating Instructions

6000 Series Patch Panel Terminating Instructions 6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four

More information

LGX Compatible (LSX) Connector Module) User Manual)

LGX Compatible (LSX) Connector Module) User Manual) LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1

More information

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex

More information

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules Overview Telect's HDX and ELF CPRI Interface Panels and Modules provide non-service affecting monitor ports to be installed between the Optical CPRI Base Band Unit (BBU) and the Remote Radio Head/ Active

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Multiplexer Enclosure and Cabling December 00 Figure - Trase Unit and Multiplexer Enclosure BNC Coaxial Cables From s (in order) MULTIPLEXER MODEL: 00B R / / / / / / / 9 0 9 0 Multiplexer

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2

More information

APPENDIX A Verify All Part Numbers (Partial List of Approved Products)

APPENDIX A Verify All Part Numbers (Partial List of Approved Products) SECTION 16651 APPENDIX A Verify All Part Numbers (Partial List of Approved Products) SYSTIMAX SCS: OVER-VOLTAGE PROTECTION 1. Over-voltage Protection Device, 100-Pair with Enclosure, Product 489ACAI-100,

More information

Medium Box for Cable Termination

Medium Box for Cable Termination FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling

More information

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and

More information

What is SnoCam? SnoCam Installation Guide. SolarVu

What is SnoCam? SnoCam Installation Guide. SolarVu 4 1 2 3 4 5 6 7 8 D+ Rx- GND V+ GND V+ Power 1 2 3 4 5 6 7 8 9 10 What is? SolarVu Installation Guide SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over

More information

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories Evolution Cable Management Page 5-3 Velocity Cable Management Page 5-8 Velocity Standard Pack Page 5-12 Vertical Cable Management Page 5-13 Global

More information

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP 0G A is Siemon s advanced, end-to-end augmented category UTP structured cabling system, designed to meet or exceed all 0GBASE-T performance requirements, including alien crosstalk. Siemon s full channel

More information

WaveTrax. Fiber Cable Management System

WaveTrax. Fiber Cable Management System Table of Contents Overview...3 Trough...4 Trough Cover...4 Trough Notching Tool...4 FastLock Coupler...4 Competitive FastLock Coupler...5 Horizontal Elbow...5 Horizontal Elbow Cover...5 Horizontal T...5

More information

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels

More information

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

A. All communications equipment rooms shall be installed in a neat and workmanlike manner. SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door CHAPTER 8 Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door July 13, 2012, This document provides you with the procedures you perform to assemble and mount the

More information

4320 SS-25 Self-Strip Terminating Block

4320 SS-25 Self-Strip Terminating Block 4320 SS-25 Self-Strip Terminating Block Instructions May 2002 78-8130-7677-1 1.0 General The 3M 4320 SS-25 Self-Strip Terminating Block is a factory stubbed, self-stripping connecting block designed for

More information

12G Broadcast connectors

12G Broadcast connectors 12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high

More information

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

CONNECTING THE FUTURE 19 LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

Cable and Power Management Open-Frame Rack Cable Managers

Cable and Power Management Open-Frame Rack Cable Managers Spec-001 Cable and Power Management Open-Frame Rack Cable Managers CABLETEK Horizontal Cable Manager DCHD shown DCHS4 shown Arrowhead fingers funnel cable into base and hold it securely Vertical and horizontal

More information

NGF optical distribution frame

NGF optical distribution frame NGF optical distribution frame Contents Introduction 3 Product overview 3 Things to consider when ordering 4 Frame capacity requirements (important facts on trough space) 4 Frame lineup capacity comparisons

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

RouteIT Cable Managers

RouteIT Cable Managers RouteIT Cable Managers Siemon's new RouteIT vertical and horizontal cable managers are specifically designed to readily manage the challenges proposed by today s high volume, high density cabling systems.

More information

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions High Density Block BRCP HD BRCP- 128/192/256 pair Installation Instructions Product Introduction The BRCP block is the latest generation of MDF terminal blocks developed by 3M, specifically designed for

More information

HCS - HES Cabling Systems

HCS - HES Cabling Systems HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE FIBER OPTIC SWING-OUT PATCH PANEL INSTRUCTION

More information

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

August  BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19 PATCH PANEL - 24x STP CAT6A PORTS 19 BLANK PATCH PANEL FOR STP KEYSTONE JACKS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS WITH EXTRA LONG STRAIN RELIEF BAR The 24-port blank patch panel is designed to use with STP keystone jacks. It can hold up to 24 RJ45 keystone jacks. It features

More information

IP-LINX. Installation Guide

IP-LINX. Installation Guide Installation Guide Installation Guide, 146653-4 Copyright 2017, Telect, Inc. All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 22425 East Appleway Ave. # 11

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page

More information

Amphenol RF Connectors

Amphenol RF Connectors Amphenol RF Connectors 007 901-9601 SMA PLUGS & ANGLE PLUGS FOR FLEXIBLE CABLE 50X IMPEDANCE Conn. Attachment RG-/U Outer Inner 901-9511-12SF Dbl. Braid RG-316 Plug Br. Solder $17.49 901-9531-12SF Angle

More information

Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION

Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION Contact Information NORTH AMERICA United States Winchester Electronics World Headquarters 62 Barnes Industrial Road North Wallingford,

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 75 OHM AND 75 OHM HD COAXIAL CONTACTS AND MODULES Table of Contents SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS Rev B. 13 August 2017 ASSEMBLY INSTRUCTIONS The Midnight Ultimate Keyer (MUK) consists of two functional assemblies: Rear Panel containing the interface and power connectors. Front Panel containing the

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

Table 4-1: Rating Levels

Table 4-1: Rating Levels OBJECTIVES 1. Describe various level ratings that apply to telecommunication cables and jacks and identify where each is implemented. 2. Describe the various levels of the cabling category rating systems.

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

I/A Series Hardware Fiber Optic LAN Converter

I/A Series Hardware Fiber Optic LAN Converter I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

SMART CLASSix 24/48 UTP Patch Panels -

SMART CLASSix 24/48 UTP Patch Panels - Features Support 24 ports per 1U, 48 ports per 2U. Conform to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. Simple labor-saving termination

More information

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1 Modular Solutions Subject to technical changes! 1 Since 1986, braun telecom has stood for continuity and competence in broadband communication and has become one of the leading suppliers of products and

More information

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation Broadband Cable Networks August 30, 2007 1(8) CXX Series User Manual Teleste Corporation CXE800 Fibre Optic Receiver Broadband Cable Networks August 30, 2007 2(8) Introduction The CXE800 is a unidirectional,

More information

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual, Part Number

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

IP-LINX Fiber :: X-XXXX

IP-LINX Fiber :: X-XXXX Fiber :: 055-797X-XXXX User Manual Telect, Inc. All rights reserved. 146653-A0 Table of Contents Chapter 1: Introduction...3 1.1 Tools Required...3 1.2 Additional Parts...3 1.3 Assemblies...3 Chapter 2:

More information

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/ 11/6/2009 www.elber.com elber@elber.it TCU/RCU RF Head Control Units User Manual Elber s.r.l.- Via Pontevecchio, 42W Phone +39-0185.35.13.33 16042 Carasco (GE) Italy Fax +39-0185.35.13.00 1 Sommario 2

More information

Structured Cabling Introduction & Installation Guide

Structured Cabling Introduction & Installation Guide Structured Cabling Introduction & Installation Guide Structured Cabling Overview General Structure - Cat5e/Cat6 Cabling The structure illustrated has the following key points: Face plates present outlet

More information

Interactive Satellite Terminal Installation / Validation Manual

Interactive Satellite Terminal Installation / Validation Manual Installation / Validation Manual Version October 5, 2016 Index INTERACTIVE SATELLITE TERMINAL 1. FCC COMPLIANCE... 3 2. TECHNICAL FEATURES...4 3. GENERAL DESCRIPTION...5 4. ELEMENTS CONTAINED IN THE TERMINAL...6

More information

Dish Diversity Switch

Dish Diversity Switch www.travel-vision.com Dish Diversity Switch INSTALLATION & USER S MANUAL Version 3.1 October 2013 PREFACE The information in this Installation and User s Manual is subject to change in order to improve

More information

DIGITAL SWITCHERS 2100 SERIES

DIGITAL SWITCHERS 2100 SERIES DIGITAL SWITCHERS 00 SERIES HIGH PERFORMANCE DIGITAL ROUTING OPERATORS MANUAL Includes Module and Frame Information for: AUDIO DAS- DAS-88 DAS-66 VIDEO DVS- DVS-8 DVS-6 DVM-66 DVS-66 SIGMA ELECTRONICS,

More information

QUICK PATCH Coaxial Patch Panels

QUICK PATCH Coaxial Patch Panels QUICK PATCH Coaxial Patch Panels Features Unique quick connect design Auto locking Reduced weight Various standard port arrangements Positive pre-removal interlocks Replaceable contacts Standard Configurations

More information

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General

More information

ACTIVE IF SPLITTER/COMBINER UHP-IFS

ACTIVE IF SPLITTER/COMBINER UHP-IFS ACTIVE IF SPLITTER/COMBINER UHP-IFS GENERAL DESCRIPTION AND INSTALLATION GUIDE DOCUMENT RELEASE 2 [UHP.IFS.2.EN] JUNE 2016 CONTENT Acronyms and Abbreviations... 4 Introduction... 5 Required level of qualification...

More information

MAXX BOX. MX102/202 Series. MAXX Box

MAXX BOX. MX102/202 Series. MAXX Box MX102/202 Series MAXX Box MAXX BOX 1 C O N T E N T S SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical... 5 Physical...

More information

NewTek SX-SDI Serial Digital Switcher INSTALLATION

NewTek SX-SDI Serial Digital Switcher INSTALLATION NewTek SX-SDI Serial Digital Switcher Thank you for purchasing this NewTek serial digital switcher. This rack-mountable hardware adds multiple SDI video inputs to VT[4] live switching, while continuing

More information

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual Manual DigiLink DLC156 Function modules Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI Installation and Operations Manual WWW.ARTEL.COM ii DLC156 Function Modules Installation and Operations Manual

More information

Tools Amphenol CTL Crimp Series

Tools Amphenol CTL Crimp Series CTL Crimp Series Bench Mounted Pneumatic Crimp Machine This pneumatic-powered crimp tool makes production termination for coaxial cable easy, efficient and precise. Our compact (less than 20 pounds) unit

More information

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683 SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683.01.01 GENERAL A. The Contractor shall furnish the designated quantity of Video Optical Transceiver (VOTR) pairs

More information

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual 100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Coupling Tray FDTC-10S-COUPLINGTRAY 3M Coupling Tray FDTC-10S-COUPLINGTRAY for use with 3M Fiber Dome Closures FDC 10S Instructions July 2010 3 1.0 Introduction The 3M Coupling Tray FDTC-10S-COUPLINGTRAY can accommodate up to 10 loose tubes.

More information

G4HUP Panoramic Adaptor Installation FT950

G4HUP Panoramic Adaptor Installation FT950 G4HUP Panoramic Adaptor Installation FT950 These instruction cover installation of the PAT board in the 1st IF of the FT950 69.45MHz this gives access to all receiver options on the main receiver. The

More information

Brown University. Communications Standard Parts List

Brown University. Communications Standard Parts List CIS - NTG Brown University Communications Standard Parts List All data installations must receive the 25-year Mission Critical Warrantee from Hubbell Premise Wiring. All fiber installations must receive

More information

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL COMPOSITE VIDEO METER MODEL VLM- COMPOSITE VIDEO METER MODEL VLM- NTSC TECHNICAL INSTRUCTION MANUAL VLM- NTSC TECHNICAL INSTRUCTION MANUAL INTRODUCTION EASY-TO-USE VIDEO LEVEL METER... SIMULTANEOUS DISPLAY...

More information

1 Remove SCREWS (2) CELL-EXT Cable Assembly Installation Guide. LYNX Touch/QuickConnect Touch Controls. General Information. Remove the 3GL/3GLC

1 Remove SCREWS (2) CELL-EXT Cable Assembly Installation Guide. LYNX Touch/QuickConnect Touch Controls. General Information. Remove the 3GL/3GLC CELL-EXT Cable Assembly Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/mywebtech General Information The CELL-EXT cable assembly is used to connect

More information

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber

More information

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap MAX 5e UTP Modules MAX 5e modules exceed category 5e performance with component and channel performance to 60 MHz. These modules offer all the functional advantages of our MAX 6 modules in a variety of

More information

Belden IBDN System 10GX 10GX Modules and 10GX Patch Panels

Belden IBDN System 10GX 10GX Modules and 10GX Patch Panels C O M M E R C I A L N E T W O R K I N G C O P P E R 5.6 Belden IBDN System GX GX Modules and GX Patch Panels AX2272 GX Module, Black GX Module The GX Module is a revolutionary punch down UTP connector

More information

RF Characterization Report

RF Characterization Report BNC7T-J-P-xx-ST-EMI BNC7T-J-P-xx-RD-BH1 BNC7T-J-P-xx-ST-TH1 BNC7T-J-P-xx-ST-TH2D BNC7T-J-P-xx-RA-BH2D Mated with: RF179-79SP1-74BJ1-0300 Description: 75 Ohm BNC Board Mount Jacks Samtec, Inc. 2005 All

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

MODULAR A/V CABLING SOLUTIONS MODULAR A/V CABLING SOLUTIONS

MODULAR A/V CABLING SOLUTIONS MODULAR A/V CABLING SOLUTIONS RapidRun is the most complete audio/video cabling system built to save installation time, accommodate changes, and reduce the likelihood of return service calls due to faulty field terminations. RapidRun

More information

The HellermannTyton AlphaSnap patch panel features the ultimate in patch panel technology. In addition to providing superior performance levels, the

The HellermannTyton AlphaSnap patch panel features the ultimate in patch panel technology. In addition to providing superior performance levels, the The HellermannTyton AlphaSnap patch panel features the ultimate in patch panel technology. In addition to providing superior performance levels, the AlphaSnap panel features a unique and patented slide

More information

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on and Shutters with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel 24 Snap-in Connectors with Sliding mechanism

More information

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Wall Mount Enclosure 8430 Series 3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6

More information

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems Instruction Manual... light years ahead S739DV & S7739DV Video and Up-the-Coax Control Systems Fiber Options Federal Communications Commission and Industry Canada Radio Frequency Interference Statements

More information

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description Headend Systems Series 9900 RF Signal Manager Modules Introduction Advanced HFC networks now include numerous 2-way interactive services that offer significant new sources of revenue for the system operator.

More information

PATCH PANEL Easy Patch INSTRUCTION MANUAL

PATCH PANEL Easy Patch INSTRUCTION MANUAL Page 1 BDA82-0 PATCH PANEL Easy Patch 96 Bantam (TT) Jacks 50 pin D-subminiature NPPA-TT-SD50 Easy Patch NPPA-TT-SD50 Page 2 BDA82-0 Index page 1 Electrical configuration 3 2 Re-Configuration and Replacement

More information

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each

More information

TVP-20 / RVP-412 CCTV VIDEO-PLEXER

TVP-20 / RVP-412 CCTV VIDEO-PLEXER TVP-20 / RVP-412 CCTV VIDEO-PLEXER INSTRUCTION BOOK IB640701 4-1-2003 TABLE OF CONTENTS DESCRIPTION 3 MOUNTING INSTRUCTIONS 3 RVP-412 MOUNTING INSTRUCTIONS 3-4 HOW TO CABLE THE TVP-20 5 HOW TO CABLE THE

More information

Field Service Procedure Receive Path Troubleshooting

Field Service Procedure Receive Path Troubleshooting 1. Brief Summary: Troubleshooting document for diagnosing a fault with the receive path of an installation. 2. Checklist: Switch LNB Bands Connection Issue LNB Power Bands Switching Correctly 3. Theory

More information

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published White Paper How to Specify MTP Pre-terminated Optical Cabling Published January 2009 The benefits of pre-terminated cabling The two principal advantages of pre- terminated cabling are reduced time on site

More information

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM g GE Interlogix Fiber Options Instruction Manual S700V & S702V FIBER-OPTIC VIDEO TRANSMISSION SYSTEM Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment

More information

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section in

More information

DSX-1. Copper :: DS1 Series User Manual. Applys to : DS1 Series BATT RTN SGND MON OUT. T Out R T. Front Cross-Connect TL T R T R. Out.

DSX-1. Copper :: DS1 Series User Manual. Applys to : DS1 Series BATT RTN SGND MON OUT. T Out R T. Front Cross-Connect TL T R T R. Out. User Manual BATT RTN SGND MON OUT IN Front Cross-Connect TL T Out R T I n R T R T R Out In NE Applys to : DS1 Series Table of Contents 1.1 Purpose and Scope...1 1.2 Description...1 1.3 Definitions...2

More information

TracVision R6DX Installation Guide

TracVision R6DX Installation Guide TracVision R6DX Installation Guide These instructions explain how to install the TracVision R6DX satellite TV antenna system on an RV or motor coach. Complete instructions on how to use the system are

More information

Azatrax Model Railroad Track Signal Control - Single Track

Azatrax Model Railroad Track Signal Control - Single Track Installation Guide Azatrax Model Railroad Track Signal Control - Single Track TS2 What it is: The TS2 operates one or two trackside block signals (one in each direction) on one track to simulate the block

More information

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual Manual DigiLink DLC103A Function module 3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater Installation and Operations Manual WWW.ARTEL.COM ii DLC103A Function Module Installation

More information

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz ASSEMBLY AND INSTALLATION A449-6S 70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951425 (7/93) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN

More information

1x12 VGA & Audio over CAT5 Splitter

1x12 VGA & Audio over CAT5 Splitter SP-9112 1x12 VGA & Audio over CAT5 Splitter User Manual rev: 160322 Made in Taiwan Safety and Notice The SP-9112 1x12 VGA & Audio over CAT5 Splitter has been tested for conformance to safety regulations

More information

Optimizing BNC PCB Footprint Designs for Digital Video Equipment

Optimizing BNC PCB Footprint Designs for Digital Video Equipment Optimizing BNC PCB Footprint Designs for Digital Video Equipment By Tsun-kit Chin Applications Engineer, Member of Technical Staff National Semiconductor Corp. Introduction An increasing number of video

More information

3M Fiber Closures BPEO

3M Fiber Closures BPEO 3M Fiber Closures BPEO 2 3M Fiber Closures BPEO The 3M Fiber Closures BPEO are designed with flexibility in application in mind. With a range of sizes, they can be deployed above grade (pole, facade) or

More information