1 ADC Passive ptical Network (PN) Test and Turn-Up Procedures ADCP-96-4 Issue 4/009 Content Page INTRDUCTIN LIST F ACRNYMS AND ABBREVIINS GENERAL INFRMIN Test Instrumentation TESTING C Fiber Distribution Frame to SP Feeder Cable through Splice Points C to Splitter utput in FDH FDH to Distribution Cable FDH to TURN UP Central ffice FDH Splitter Cabinet Access Terminal Final verification and tests CUSTMER INFRMIN AND ASSISTANCE INTRDUCTIN This document discusses installation testing of a typical FTTH Passive ptical Network (PN) cable plant using connectorized splitters. The PN network can be divided into several logical sections for testing purposes. Sectional testing solutions are dependant upon the required Quality of Service. Revision History ISSUE DE REASN FR CHANGE 4/009 riginal. List of Changes PAGE IDENTIFIER DESCRIPTIN F CHANGE All New Rev A Page
2 Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc. Related Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC Technical Assistance Center at (in U.S.A. or Canada) or , extension 7347 (outside U.S.A. and Canada). Title/Description ADC ptical Return Loss (RL) Testing ADCP Number ADCP Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. General Safety Precautions Caution: Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend radius. Always observe the recommended bend radius limit when installing fiber optic cables and patch cords. Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. Caution: Improper handling can damage fiber optic cables. Do not bend fiber optic cable more sharply than the minimum recommended bend radius specified by the cable manufacturer. Do not apply more pulling force to the cable than specified. Do not compress the fiber or allow it to kink. Page
3 Warning: Invisible infrared radiation can seriously damage the retina of your eye. Do not look into the launching (output) end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating bulkhead receptacle or optical connector to avoid exposure to potentially dangerous amounts of radiation. This practice also helps to prevent contamination of connectors and adapters. LIST F ACRNYMS AND ABBREVIINS The acronyms and abbreviations used in this manual are detailed in the following list: C FDF DN LT NT SP TDR PN RX SMFC SMLC SMSC SRC TX Access Terminal Central ffice Fiber Distribution Frame Fiber Distribution Hub/Terminal ptical Distribution Network ptical Line Termination ptical Network Termination utside Plant ptical Time Domain Reflectometer Passive ptical Network Radio Frequency Receive SingleMode FC SingleMode LC SingleMode SC Source Transmit Value Added Module Wave Division Multiplexer Page 3
4 GENERAL INFRMIN Failure to adequately test to an acceptable level at the time of installation will result in customer dissatisfaction. To achieve adequate testing requires careful consideration and planning. It is possible to achieve adequate testing at a reasonable price, however poor planning will result in inadequate testing with a higher initial cost. A PN network is a Point to Multipoint architecture servicing a number of customers. Testing is more complex than in traditional Point to Point because a given customer s circuit is composed of both shared and dedicated fiber. Indeed, the increased test complexity, combined with increased cost constraints, means that testing needs to be very carefully evaluated and implemented. PN networks use passive splitters to distribute fiber to individual homes or businesses. ne fiber is optically split into 6, 3, 64, or more fibers, which are then distributed to residential or business subscribers. The switching and routing is done at the carrier's central office. nce on the customer's premises, the fiber connects to a Network Interface Device (NID), called variously an ptical Network Termination (NT) or an ptical Network Unit (NU). This device converts the optical signal into a format that can be used directly by the customer.. Test Instrumentation Several instrument types may be used to perform PN installation tests as shown in Table. Table. Typical PN Test Instruments TEST MEASUREMENT INSTRUMENT PURPSE F TEST TEST CMPLEXITY Connector Microscope Check contamination Check end face quality Fiber Identification Section Loss VLS Fiber Identifier Source & Meter Source & meter or Loss Test Set Identification of designated fiber Section loss of the cable Pass/Fail evaluation Warranty System RL RL meter / LTS Ensure RL is within design parameters. E.g. ITU-G-983 Cable characterization PN TDR Physical fault location Loss & reflection at joints Easy Easy - Medium Easy Splice Loss Splicer with auto-alignment Check Splice Loss Easy ptical Power Selective Power Meter Check Transmission Power Easy Faulty NID NID Diagnostics Spare NID Determine if NID has a fault Easy Head Room In line attenuator Determine if design transmission margin is met. Easy Easy - Medium High to very high Page 4
5 This document provides general guidelines for the Test and Turn Up Procedures for a PN Network. It is assumed that the correct placement and construction of all cabinets and terminals has been completed and verified. A typical network is shown in Figure. Danger: Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned-off or that the fiber is disconnected at the other end. CRSS-CNNECT CNTENT VIDE LT LT MDULE FDH (also known as FDT) 3 DISTRIBUTIN NT (TYP) DRP (TYP) 347-A Figure. Typical Communications Network TESTING This section contains testing procedures for the portions of the network and components circled in Figure. Always start at one end of the network under test and work your way to the opposite end. CRSSCNNECT C D CNTENT VIDE LT LT A MDULE B 3 E DRP 343-A NT DISTRIBUTIN Figure. Passive ptical Network A B C D E Section. Section. C Fiber Distribution Frame to SP Feeder Cable through Splice Points Section.3 C to Splitter utput in FDH Section.4 FDH to Distribution Cable Section. FDH to Page
6 Table. Loss Specifications ITEM/CMPNENT AVERAGE LSS PER UNIT F MEASUREMENT NTES CNNECTRS SPLICING APC 0.3 db Loss per mated connector Single Fusion 0.04 db Loss per splice Mass Fusion 0. db Loss per splice SPAN LENGTH SPLITTERS nm 0.4 db/km Loss per Km of fiber placed /nm 0.3 db/km Loss per Km of fiber placed x 3.7 db Loss per splitter x4 7. db Loss per splitter x db Loss per splitter x6 4.0 db Loss per splitter x3 7.0 db Loss per splitter x db Loss per The applicable standards that cover optical couplers are G.67 from ITU and GR-09 from Telcordia. Values may vary per manufacturer.. Light Source & Power Meter Test. Using a light Source & Power Meter, test through the to ensure the device is operating per manfacturers specifications. See Figure 3 for typical schematic.. Record the values observed during the test. MDULE nm UT CMMN nm IN/ nm UT 348-A Figure 3. Schematic Page 6
7 . C Fiber Distribution Frame to SP Feeder Cable through Splice Points This test is done to establish correct connectivity and verify low splice loss through the fiber distribution frame infrastructure, see Figure 4... TDR Test. Conduct TDR test from fiber distribution frame through the SP feeder cable. CRSSCNNECT CNTENT VIDE LT LT MDULE B 3 DISTRIBUTIN DRP NT 349-A Figure 4. Continuity and Splice Loss Test. Verify the loss is equal to or less than the component values in Table. 3. Record the values..3 C to Splitter utput in FDH Test C Fiber Distribution Frame through feeder cable, splice points and splitter in the FDH. This test is used to verify that new splitters are installed correctly before service is placed on the feeder cable, see Figure..3. Light Source & Power Meter Test. Using a Light Source & Power Meter, test from the C FDF through the feeder cable and FDH splitter to splitter output. Page 7
8 C CRSSCNNECT CNTENT VIDE LT LT MDULE 3 DISTRIBUTIN DRP NT 340-A Figure. Splitter Installation Testing. Calculate or determine the loss specifications from Table. 3. Record the values..4 FDH to Distribution Cable Test from FDH splitter cabinet out through the distribution cable splice points, see Figure 6. This test is done to establish correct connectivity and low splice loss through the distribution side of the FDH. CRSSCNNECT D CNTENT VIDE LT LT MDULE 3 DISTRIBUTIN DRP NT 34-A Figure 6. to Distribution Cable Testing Page 8
9 .4. TDR Test. Conduct TDR test from the FDH splitter cabinet through the SP distribution cable.. Verify the loss is equal to or less than the component values in Table. 3. Record the values. Miscellaneous trace views and descriptions can be found in the ADC ptical Return Loss (RL) Testing document ADCP FDH to Test Distribution Network from FDH through splice points and Access Terminal (). This is a test to verify the distribution link from the FDH to the, see Figure 7... Light Source & Power Meter Test. Using the Source & Power Meter, test from the FDH splitter cabinet through the distribution cable output. CRSSCNNECT CNTENT VIDE LT LT MDULE E 3 DISTRIBUTIN DRP NT 34-A Figure 7. to Testing. Calculate or determine the loss specifications from Table. 3. Record the values. Page 9
10 .. TDR Test to verify and establish the distance from the FHD to.. Conduct TDR test from the FDH through the SP distribution cable.. Verify the loss is equal to or less than the component values in Table. 3. Record the values. 3 TURN UP 3. Central ffice If not already complete, connect from the Packet LT to the PN Port (/nm) of the. If not already complete, connect from the Video LT to the Video Port (nm) of the. Cross-Connect from the Common Port of the to the applicable SP Feeder Cable Port on the Fiber Distribution Frame. 3. FDH Splitter Cabinet If not already complete, connect from the splitter output to the assigned SP Distribution Cable Port. 3.3 Access Terminal If not already complete, connect from the to the NT. 3.4 Final verification and tests. Complete bidirectional Source & Power Meter and TDR testing of the entire PN network from the to the NT. Page 0
11 4 CUSTMER INFRMIN AND ASSISTANCE PHNE: U.S.A. or CANADA Sales: Extension Technical Assistance: Connectivity Extension: 7347 Wireless Extension: EURPE Sales Administration: Technical Assistance: EURPEAN TLL FREE NUMBERS Germany: UK: Spain: France: Italy: ASIA/PACIFIC Sales Administration: Technical Assistance: ELSEWHERE Sales Administration: Technical Assistance: WRITE: 3944-Q ADC Telecommunications (S PRE) PTE, LTD; 00 Beach Road, #8-0, Shaw Towers. Singapore ADC Telecommunications, INC P Box 0, Minneapolis, MN 440-0, USA ADC European Customer Service, INC Belgicastraat, 930 Zaventem, Belguim PRDUCT INFRMIN AND TECHNICAL ASSISTANCE: connectivity.tac@adc.com wireless.tac@adc.com euro.tac@adc.com asiapacific.tac@adc.com REPRINTS: PDF copies of manuals are available for downloading at the following link: ADCP Number: 96-4 Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. Page
OptEnet OC48 Regenerator Module User Manual
OptEnet OC48 Regenerator Module User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................
More information6000 Series Patch Panel Terminating Instructions
6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four
More informationNext Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)
Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual) Fiber Combination Block Content Page INTRODUCTION............................................................................. 2 Revision
More informationOmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet
OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet ADCP-90-457 Issue 1 9/2010 Content Page INTRODUCTION.............................................................................
More informationTraditional RF Splitter/Combiner and Directional Coupler User Manual
Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1
More informationTraditional RF Splitter/Combiner and Directional Coupler User Manual
Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1
More informationLGX Compatible (LSX) Connector Module) User Manual)
LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1
More informationField Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks
Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture
More informationSSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2
SSA Fibre-Optic Extender 160 Version 1.2 0.1 Introduction This document provides information on the specification and installation of optical fibre networks to support SSA optical extender products. SSA
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and
More informationDESIGN!!GUIDELINES!!!!!
DESIGNGUIDELINES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 1. Testing General 1.1. For acceptance, 100% of the media
More informationMAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide
MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels
More informationSignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.
SignalOn Series D3.1/CCAP Compliant 1.2 GHz L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com Although every effort has been taken to ensure the accuracy
More informationWe will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).
Nuclear Sensors & Process Instrumentation Fiber Cable Basics Fiber-optic communication is a method of transmitting information from one place to another by sending light through an optical fiber. The light
More informationProduct Operation Manual
Product Operation Manual VL-FTX FORWARD TRANSMITTER MODULE Ver 1.1(Doc#01-02-008) VALE SYSTEMS INC. 10400 Overland Road #408 Boise, ID 83709-1449,USA Tel: 208.935.6317Fax: 208.935.6234 All rights reserved
More informationENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE
ENGINEERING MITTEE Interface Practices Subcommittee SCTE STANDARD SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society of Cable Telecommunications
More informationUser Guide. HDMI Fiber Optic Extender. DVI-7350a
User Guide HDMI Fiber Optic Extender DVI-7350a Table of Contents Section Page Product Safety.................................... 1 1.0 Introduction...2 2.0 Specifications...3 3.0 Package Contents...3 4.0
More information3M Fiber Optic Wall Mount Enclosure 8430 Series
3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6
More informationVersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA
VersiVision FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 4-CHANNELS BI-DIRECTIONAL AUDIO 4-CHANNELS BI-DIRECTIONAL CONTACT CLOSURE 1-CHANNEL
More informationPerle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)
Perle Fast Ethernet Fiber to Fiber Media Converter Module Installation Guide C-100MM-XXXXX CM-100MM-XXXXX Unmanaged Module Managed Module P/N 5500313-10 (Rev D) Overview This document contains instructions
More informationPluggable Transceivers Installation Guide
Pluggable Transceivers Installation Guide 121140-04 Published November 2017 Copyright 2017 Extreme Networks, Inc. All rights reserved. Legal Notice Extreme Networks, Inc. reserves the right to make changes
More informationViavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation
Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation Scope Version 4 January 2018 Firmware 26.0.0.6c1973b or Later REQUIRED! This document describes Common Public Radio Interface (CPRI) testing
More informationVersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.
VersiVision FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL Revision B April 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702
More informationThe Road to Single Mode: Direction for choosing, installing and testing single mode fiber
The Road to Single Mode: Direction for choosing, installing and testing single mode fiber Adrian Young Leviton Network Solutions Jim Davis Fluke Networks Adrian Young, Sr. Applications Engineer Leviton
More informationL-Band Fiber Optic Link
One Jake Brown Road Old Bridge, NJ 08857-1000 USA (800) 523-6049 (732) 679-4000 FAX: (732) 679-4353 www.blondertongue.com INSTRUCTION MANUAL L-Band Fiber Optic Link For Direct Broadcast Satellite Distribution
More informationFiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12
Fiber Optic Testing Testing is used to evaluate the performance of fiber optic components, cable plants and systems. As the components like fiber, connectors, splices, LED or laser sources, detectors and
More informationDSX-1 Cross-Connect Procedures
ADCP-80-348 DSX-1 Cross-Connect Procedures 4-12000-0069 DSX-1 CROSS-CONNECT PROCEDURES ADCP-80-348 Content Page 1. CROSS-CONNECT ROUTING RULE PARAMETERS... 1 2. CROSS-CONNECT CABLE TYPE, LENGTH, AND LEVELS...
More informationFIBER QUICKMAP. Users Manual. Multimode Troubleshooter
FIBER QUICKMAP Multimode Troubleshooter Users Manual January 2011, Rev. 1 7/11 2011 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY
More informationJob Aid Server and CSS Separation Avaya S8700 Media Server
Overview of server separation Job Aid and CSS Separation Avaya S8700 Media This job aid provides information regarding the separation of S8700 Media s and the Separation of duplicated Center Stage Switch
More informationDVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL
DVBus 8350-16 and 8350-4 Multiplexer and demultiplexer assemblies for 16-4 video channels, with bidirectional audio and data USER MANUAL 1. Description. Indicators and system connections DVBus 8350 systems
More informationHow to accelerate your cabling system approvals
How to accelerate your cabling system approvals Adrian Young Fluke Networks November, 2013 Singapore Objectives for this session Resolve field failures on the spot Look at real world examples of fault
More informationSmall Form-Factor Pluggable (SFP) Module Installation Guide
Silver Peak Systems Small Form-Factor Pluggable (SFP) Module Installation Guide April 2018 201294-001 Rev A Contents Introduction... 2 Laser Compliance... 2 Federal Communications Commission Notice...
More informationSPECIAL SPECIFICATION 6559 Telecommunication Cable
2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,
More informationVersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO
VersiVision FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO TRANSMITTER / RECEIVER MULTIPLEXERS USER S MANUAL Revision B April 2013
More informationSECTION TESTING, IDENTIFICATION AND ADMINISTRATION
PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification
More informationopengear OPG-1L 50 MHz-2.3 GHz
MODEL opengear OPG-1L 50 MHz-2.3 GHz RF FIBER OPTIC LINK EMCORE s opengear OPG-1L s are optimized to perform in the 50 MHz to 2.3 GHz frequency range providing transparent signal transport for satellite
More information400G-FR4 Technical Specification
400G-FR4 Technical Specification 100G Lambda MSA Group Rev 1.0 January 9, 2018 Chair Mark Nowell, Cisco Systems Co-Chair - Jeffery J. Maki, Juniper Networks Marketing Chair - Rang-Chen (Ryan) Yu Editor
More informationSPECIAL SPECIFICATION 8540 Telecommunication Cable
2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,
More informationSidelighter TM Optical distance to fault measurement module
Sidelighter TM Optical distance to fault measurement module Available only at: Sidelighter TM Introducing the latest in optical fiber measurements and versatility Artisan Laboratories Corporation s hand
More informationIntroducing Ultra Short LC : Fiber Optic Cable Assemblies
Introducing Ultra Short LC connector based, high quality single mode and multi mode fiber optic cable assemblies have been designed to meet the highest and most demanding Industry standards. The newly
More informationUser Guide. DVI + HDCP Fiber Optic Extender DVI-7330
User Guide DVI + HDCP Fiber Optic Extender DVI-7330 TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1. INTRODUCTION...2 2. SPECIFICATIONS...3 3. PACKAGE CONTENTS...4 4. INSTALLATION...4
More informationCFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit
CFMFF1317-210 SC, 1300 nm multimode CFMFF1717-210 60 km (37.2 miles) CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit Transition Networks CFMFFxxxx-2xx series
More informationLight Source. Specification & User Manual
Light Source Specification & User Manual Page 1 of 11 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
More informationSignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.
SignalOn Series D3.1/CCAP Compliant 1.2 GHz L-Band Splitter Module INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com Although every effort has been taken to ensure the accuracy of
More informationFiber Optic Meter Fiber Optic Source
FOM/FOS Fiber Optic Meter Fiber Optic Source Warning To avoid injury: do not service the FOM or FOS unless you are qualified to do so. The service information provided in this document is for the use of
More informationSLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.
SLS-50 Stabilized Laser Source User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the
More informationModel OTDV Broadcast Transport Links OPERATING MANUAL
Model OTDV-1250 Broadcast Transport Links OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 Rev. X5 E-Mail: sales@olsontech.com 02/23/10 Table of Contents
More information4 Channel Video over Fiber With Ethernet
4 Channel Video over Fiber With Ethernet Fiber Optic Converters MX 3260 MDR Electronics www.mdrelectronics.com Table of contents 1. Introduction 3 2. Image 4 3. Specifications 5 4. Connection Diagram 6
More informationU SER S G UIDE. TS2002A Fiber Optic Test Kit
U SER S G UIDE TS2002A Fiber Optic Test Kit TS2002A Test System Black Box TS2002A test system performs optical power loss measurement for both multimode and single-mode LAN/WAN fiber optic installations.
More informationCable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available
Fiber Optic Products FIBER OPTIC PRODUCTS FIBER OPTIC PATCH CORD CABLE The Construction of a Fiber-Optic Cable Cable Jacket - The outermost layer of the fiber cable. Strengthening fibers - The strengthening
More informationOTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL
OTLT / OTLR 3000 Manual L-Band Fiber Optic Link 850-3000 MHz INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: sales@olsontech.com REV. X1 www.olsontech.com 05/12/06 INSTALLATION
More informationHFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide
HFC Enhance QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments
More informationVGA to DVI Extender over Fiber SET
VGA to DVI Extender over Fiber SET Model #: FO-VGA-DVI 2011 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview
More informationCable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification
General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from
More informationThe need for Encircled Flux, real or imaginary?
Version 1.7 The need for Encircled Flux, real or imaginary? Harley Lang, RCDD Fluke Networks 14 March, 2013 Presentation agenda What s the issue Mandrels are they needed? Review of standards Coupled Power
More informationUser Guide. Single-Link DVI Active Cable Extender. DVI-7171c
User Guide Single-Link DVI Active Cable Extender DVI-7171c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY...1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE CONTENTS...4 4.0
More informationInstallation. SAPTF33xx-1xx in the Network. Standard Configuration
SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device
More information1623A/B O-Band DWDM DFB Laser Module
1623A/B OBand DWDM DFB Laser Module The 1623 ITU G.695 compliant OBand DWDM forward path DFB laser components are designed for both broadcast and narrowcast analog applications. The highly linear, OC48
More informationScope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.
Page 1 of 10 Using Technology for the PDI of the and 7SA522/7SA6 Scope: Using Wave Division Multiplexing () for the Protection Data Interface (PDI) of the 7SD5 /. Two important issues related to differential
More informationOPERATION MANUAL INSTALLATION AND KML.F. Fiber Optic Interface Main Link. Kilomux Module. The Access Company
INSTALLATION AND OPERATION MANUAL KML.F Fiber Optic Interface Main Link Kilomux Module The Access Company KML.F Fiber Optic Interface Main Link Kilomux Module Installation and Operation Manual Notice
More information40G SWDM4 MSA Technical Specifications Optical Specifications
40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope
More informationInstalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas
Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning Loss Budgets TIA (Cabling)
More informationWiBa OPERATOR S MANUAL
WiBa OPERATOR S MANUAL 2.7 GHz, Wideband ( WiBa ) Fiberoptic Link Model Description Model Description 10381 Tx, Un-amplified, 10 to 2700 MHz, 50 10481 Rx, 10 to 2700 MHz, 50 10382 Tx, Amplified, 10 to
More informationTech Breakfast: Fibre Optic Cabling
Tech Breakfast: Fibre Optic Cabling An introduction phil.crawley@jigsaw24.com @IsItBroke on Twitter http://www.root6.com/author/phil Fibre optic cabling Applications within Film & TV Single mode vs. Multi
More informationUser Guide. HDMI Active Cable Extender. DVI-7370c
User Guide HDMI Active Cable Extender DVI-7370c TABLE OF CONTENTS SECTION PAGE PRODUCT SAFETY...1 PRODUCT LIABILITY STATEMENT........................ 1 1.0 INTRODUCTION...2 2.0 SPECIFICATIONS...3 3.0 PACKAGE
More informationABCD. Application Note No Reeve Engineers. Transmission Level Point. 1. Introduction. 2. Application of the TLP
ABCD E Application Note No. 8 1996 Reeve Engineers Transmission Level Point 1. Introduction This application note covers the concept of the Transmission Level Point, or TLP. Another related application
More informationDatasheet: SimpliFiber Pro
Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro SimpliFiber Pro makes testing simple Fluke Networks' SimpliFiber Pro Optical Power Meter incorporates new and innovative features to give technicians
More informationT-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS T-BERD /MTS-6000, -6000A and -8000 Platforms OFI Multifunction Loss Test Module Key Features One-button automated testing, including continuity check, bidirectional
More informationTETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL
TETRA 42x0 Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL 1. General description TETRA 42x0 (4210 for multimode, and 4250 for singlemode) digital-optical multiplexer/demultiplexer
More informationRCIT Cable Certification Testing Revised 10/2017
RCIT Testing Revised 10/2017 General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall
More information40G SWDM4 MSA Technical Specifications Optical Specifications
40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope
More informationTwo (2) fibers Detachable DisplayPort Extender
ㅕ Two (2) fibers Detachable DisplayPort Extender Manual Contents Manual Contents 1-0 Welcome! Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting 1-5 Maintenance,
More informationOPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED logo are trademarks of Optica Technologies Incorporated.
Optica Technologies Incorporated 34600 FXBT Converter Quick Start Guide Product Warranty Safety Warnings 34600/070208 Trademarks OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED
More informationFTK200. Users Guide. Optical Fiber Test Kit
FTK200 Optical Fiber Test Kit Users Guide April 2000, Rev. 1 4/03 2000, 2003 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective companies. LIMITED
More informationOmniStar GX2 Headend Optics Platform
arris.com OmniStar GX2 Headend Optics Platform GX2 EM1000 Series 1550 nm Broadcast Transmitter FEATURES Provides full performance 50 1002 MHz forward bandwidth for mixed analog and digital loading Versions
More informationMICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features
Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection
More informationSFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet
SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet For your product safety, please read the following information carefully before any manipulation of the transceiver: ESD This transceiver
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationOpticalProducts. Illuminating Your Network. Testing the World s Networks
OpticalProducts Illuminating Your Network Testing the World s Networks Fibre Optic Testers Ease of use and cost-effectiveness Trend s Family of Optical Products Has Increased The new products include Optical
More informationD3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.
HFC Enhance D3.1/CCAP Compliant QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com Although every effort has been taken to ensure the accuracy of
More informationPerle Fast Ethernet Media Converters
Perle Fast Ethernet Media Converters Installation Guide S-100-XXXXX P/N 5500301-15 Overview This document contains instructions necessary for the installation and operation of the Perle Fast Ethernet Standalone
More informationUser s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules
Part Number TN-GB-MM5 TN-GB-ESX5 TN-GB-ESX6 TN-GB-SM5 TN-GB-SM53 TN-GB-SM55 TN-GB-SM58 TN-GB-SM512 User s Guide TN-GB-xM5x Gigabit Interface Converter (GBIC) Transceiver Modules The Transition Networks
More informationLBO-HDMI-AD LINK BRIDGE TM FIBER OPTIC HDMI VIDEO CONVERTING TRANSMITTER SYSTEM
LBO-HDMI-AD LINK BRIDGE TM FIBER OPTIC HDMI VIDEO CONVERTING TRANSMITTER SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is
More information100G-FR and 100G-LR Technical Specifications
100G-FR and 100G-LR Technical Specifications 100G Lambda MSA Rev 1.0 January 9, 2018 Chair Mark Nowell, Cisco Systems Co-Chair - Jeffery J. Maki, Juniper Networks Marketing Chair - Rang-Chen (Ryan) Yu,
More informationQFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.
D INUE T N O SC DI QFMN QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com Although every effort has been taken to ensure the accuracy of
More information3M No Polish Jacketed SC/APC Connector
Communication Markets Division 3M No Polish Jacketed SC/APC Connector For use with 1.6 to 3.0 mm Jacketed Cable 3M No Polish SC/APC Connector enables fast, on-site termination of 1.6 mm to 3.0 mm jacketed
More informationST800K-U Optical Power Meter. User Manual V1.0
User Manual V1.0 Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10.
More informationSFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet
SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet For your product safety, please read the following information carefully before any manipulation of the transceiver: ESD This transceiver
More informationPerle Fast Ethernet Media Converters
Perle Fast Ethernet Media Converters Installation Guide S-100-XXXXX P/N 5500301-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of the Perle Fast Ethernet
More informationUSER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode
USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode Transition Networks F-SM-MM-06 Ethernet Media Converter extends ATM or SONET over singlemode fiber-optic cable
More informationSECTION 4 TABLE OF CONTENTS
Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for
More informationAN INTRODUCTION TO FIBER OPTICS SYSTEMS - PART II
AN INTRODUCTION TO FIBER OPTICS SYSTEMS - PART II BASIC SYSTEM DESIGN This series of articles on Fiber Optics plan to introduce the reader to the use of Fiber Optics in CATV Networks. Part 1 of the article
More informationMar11 Rev E
Product Specification 108-1832 11Mar11 Rev E MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. SCOPE 1.1. Content This specification, which meets the Optical Fiber Cabling Components
More informationT-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module Key features The market s first BPON/EPON/GPON power meter module Selective FTTx power meter
More informationLCC (Little Coaxial Connector) Installation Instructions)
LCC (Little Coaxial Connector) Installation Instructions) Content Page INTRODUCTION...1 Revision History...1 Trademark Information...1 1 TOOLS...2 1.1 Connection Tool Kit...2 1.2 Tool Illustrations...2
More informationDVI Rover 700 User Guide
DVI Rover 700 User Guide Featuring ExtremeDVI Technology DVI Rover 700 This document applies to Part Numbers: 00-00106 through 00-00141 inclusive. FCC Radio Frequency Interference Statement Warning The
More informationSPECIAL SPECIFICATION 6191 Fiber Optic Cable
2004 Specifications CSJ 0014-02-014, etc SPECIAL SPECIFICATION 6191 Fiber Optic Cable 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials. A. General
More information3M 8900 Single-mode SC Crimplok Connector
3M 8900 Single-mode SC Crimplok Connector Technical Report June 1999 80-6110-1441-8 1 1.0 Product Description & Requirements The 3M SC Single-mode Crimplok Connector is designed to provide the customer
More informationSPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)
2004 Specifications CSJ 0086-14-046 SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials.
More informationTwo (2) fibers Detachable DisplayPort 1.2 Extender. User s Manual for the DPFX-200-TR. Manual Contents
Manual Contents Two (2) fibers Detachable DisplayPort 1.2 Extender Manual Contents 1-0 Welcome! Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Connection with DPAX 1-5 Troubleshooting,
More information