Contactors and Contactor Assemblies

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Contactors and Contactor Assemblies"

Transcription

1 Terminal designations according to EN RT10 1 contactors Ident. no. 10E 01 Sizes S0 to S12 Terminal designations according to EN RT10 2 to 3RT10 7, 3RT12, 3RT14 contactors 3RT10 1 contactors (with ) With 3RH H... auxiliary switch blocks, mountable on the front Ident. no.: 11E E 3RT10 2 to 3RT10 7, 3RT14 contactors With 3RH HA 4-pole auxiliary contact block, mountable on the front Ident. no. E + 3 NC Ident. no.: 23E 3 NO + 32E 3RT1. 5, 3RT1. 6, 3RT1. 7 contactors (sizes S6, S10, S12) With 3RH DA11 2-pole auxiliary switch blocks, laterally mountable 3RH HA../-.XA..4-pole auxiliary switch blocks, 3 NO + Ident. no NC 13 3RH DA11, 3RH DE11 first laterally mountable auxiliary switch block (solid-state compatible) left right 3RH JA11, 3RH JE11 second laterally mountable auxiliary switch block (solid-state compatible) left right Contactors with 4 main contacts, size S00 3 R T 13 a n d 3 R T 15 c o n t a c t o r s 4 N O 2 N O + 2 N C Contactors with 4 main contacts, sizes S0 to S3 3 R T 13 a n d 3 R T 15 c o n t a c t o r s 4 N O 2 N O + 2 N C (3RH19 11 auxiliary switch blocks acc. to EN can be snapped on) (3RH19 21 auxiliary switch blocks acc. to EN can be snapped on) Surge suppressor (plug-in direction coded; exception: marked +/ for 3RT T... diode assembly) for sizes S00 to S3 Diode Diode assembly Varistor RC element Diode with LED Varistor with LED 2/156

2 Contactors and Contactor Assemblies Accessories for size S00 contactors and contactor relays 3RH F... auxiliary switch blocks and 3RH NF.. solid-state compatible auxiliary switch blocks, for snapping onto the front Ident. no U 4 NO Ident. no NO + 31 U 11/11 U standard 3RH AA.. and 3RH BA.. auxiliary switch blocks, for snapping onto the front, 3RH LA.. and 3RH MA.. auxiliary switch blocks, for snapping onto the front, Internal wiring Example:, cable entry from below Terminal designations according to DIN Part 5 3RT E.../2F.../2G... solid-state, time-delay auxiliary switch blocks OFF-delay WYE-delta function (Integrated varistors not shown) Accessories for size S0 to S12 contactors 3RH F..., 4-pole, 4 NO Ident. no NO NC 04 U 3RH CA.. auxiliary switch blocks, single-pole, 3RH CD.. auxiliary switch blocks, single-pole, with contacts, (terminal designations according to EN or EN ) 2/157

3 Accessories for size S0 to S12 contactors 3RH LA.. and 3RH MA.. auxiliary switch block, 2-pole, Internal wiring Example:, cable entry from below 3RH FE solid-state compatible auxiliary switch block, 4-pole, Ident. no. 3RH EA.. first laterally mountable auxiliary switch blocks (left) 3RH EA.. first laterally mountable auxiliary switch blocks (right) 3RH KA.. second laterally mountable auxiliary switch blocks (left) 3RH KA.. second laterally mountable auxiliary switch blocks (right) Terminal designations according to DIN Part 5 3RT E.../2F.../2G... solid-state, time-delay auxiliary switch blocks OFF-delay WYE-delta function 3RH GP11 interface for control by PLC Interface Contactor 2/158

4 Contactors and Contactor Assemblies and 3RH1 Control Relays Accessories for size S00 to S3 Circuit diagrams OFF-delay devices 3RT BK01, UC 110 V 3RT BL01, UC 230 V OFF-delay device 3RT BE01, DC 24 V Internal circuit diagram Internal circuit diagram 3RT BK01, UC 110 V UC 110 V A1 A3 A4 A5 B1 A2 Z+ Z t v (ms) > S00 DC L+ L Hz L1 N 3RT BF RH1...-.BF4. 60 Hz L1 N 130 S0 DC L+ L 100 3RT BE01, DC 24 V DC 24 V A1 A2 Z+ Z t v (ms) > S00 L+ L 3RT BB RH1...-.BB4. S0 L+ L 3RT BB S2 L+ L 3RT BB4. 90 S3 L+ L 3RT BB Hz L1 N 3RT BF Hz L1 N 100 3RT BL01, UC 230 V UC 230 V A1 A3 A4 A5 B1 A2 Z+ Z t v (ms) > S00 DC L+ L Hz L1 N 3RT BM4. 3RT BP RH1...-.BM4. 60 Hz L1 N 3RH1...-.BP S0 DC L+ L 400 3RT BM4. 50 Hz L1 N 400 3RT BP4. 60 Hz L1 N 400 Operation downstream of the OFF-delay device (contactor opens with a delay only in the event of a voltage failure) Operation upstream of the OFF-delay device (contactor always opens with a delay) Block diagram Typical circuit diagram: Size S0 contactor, DC operation, connected to AC 50 Hz 230 V Block diagram Typical circuit diagram: contactor, DC operation, connected to AC 50 Hz 230 V 2/159

5 and 3RH1 Control Relays Accessories for size S00 to S3 Circuit diagrams Accessories for size S00 to S3 contactors and control relays Solid-state time-delay blocks (see configuring aid on page 2/38) 3RT C... 3RT D... OFF-delay (with auxiliary voltage) 3RT16 capacitor contactors Sizes S0 and S3 3RT C... Sizes S0 to S3 3RT D... OFF-delay (with auxiliary voltage) Sizes S0 to S3 A2 can be connected to N(L ) via either the contactor or the time-delay relay optional connection A2 can only be connected to N(L ) via the time-delay relay. x don t connect Time-delay block Contactor 2/160

Bulletin 190 Compact. Combination Starters

Bulletin 190 Compact. Combination Starters 0Circuit reaker ulletin 10 ulletin 10 Compact Combination Starters Power Range 0.1...45 ulletin 10E Modular Eco Starters ulletin 10S Pre-wired Compact Starters Uses ulletin 140M Motor Protectors and ulletin

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,

More information

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page 3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

2-output DALI controller

2-output DALI controller 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 -output DALI controller Page. Use.... Technical features... 3. Overall dimensions.... 4. Connection... 5. Installation...3

More information

Electromechanical Relays

Electromechanical Relays Electromechanical Relays Industrial Plugin Electromagnetic Relays Description Relays of general application - the new relays are distinguished by a modern design, high reliability and functionality. Modern

More information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADVANTAGES Helps avoid cascading capacitor failures. Sensing

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+ /2 Introduction / 5SV RCCBs /10 5SM3 RCCBs /13 SIQUENCE 5SM3/5SU1 universal -sensitive RCCBs, type B and type B+ /18 Additional components /22 5SM2 RC units /30 5SU1 RCBOs /38 5SM6 AFD units /1 5SM6 AFD

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

Multi-Key v2.4 Multi-Function Amplifier Keying Interface Multi-Key v2.4 Multi-Function Amplifier Keying Interface ASSEMBLY & OPERATION INSTRUCTIONS INTRODUCTION The Harbach Electronics, LLC Multi-Key is a multi-function external device designed for the safe

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

Pluggable interface relays CR-M Miniature relays

Pluggable interface relays CR-M Miniature relays 2CDC 293 035 F0004 CR-M 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply voltages: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions:

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Relays and Timers Quick Selection Table

Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Relays and Timers Quick Selection Table Quick Selection Table Bulletin No. 700-FE 700-FS Type DIN Rail Timer DIN Rail Timer Control Outputs: Time Limit Instantaneous Operation Modes: N.O. or SPDT Timed SPDT DPDT, 2 N.O. + common ON-Delay, OFF-Delay,

More information

15 Series - Dimmer

15 Series - Dimmer Features Master slave system for multiple load dimming Suitable for incandescent and halogen lighting loads (with or without transformer or electronic supply) Compatible with energy saving (CF or ED) dimmable

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

Pluggable interface relays CR-M Miniature relays

Pluggable interface relays CR-M Miniature relays 2CDC 293 035 F0004 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply s: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V,

More information

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and .1 Product Overview.............................................. Relays and Timers.............................................. Miniature Controls.............................................. Contactors

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION MIL-C-22992 CLASS L COMPATIBILITY ORDERING INFORMATION ORDERING INFORMATION: Connectors are supplied with removable contacts. Contacts are supplied unassembled. Also supplied are applicable accessories

More information

Setting up the Setting up the Dragonfly 1 v June

Setting up the Setting up the Dragonfly 1 v June Setting up the 1 Introduction In this guide we'll be setting up a rather complete observatory, integrating in the Dragonfly all relevant elements: Roof, motorized with a garage-door system and including

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: XRT910-0-0-GB-XX XRT911-0-0-GB-XX XTT911-0-0-NN-XX IMPROX TRT ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL Working Environment XRT910-0-0-GB-XX... (Aluminium Extruded

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Selection table SITOP power supplies

Selection table SITOP power supplies Selection table SITOP power supplies Input voltage Output voltage 1-phase 120 V AC, 230 V AC Output current SITOP compact LOGO!Power SITOP lite SITOP smart SITOP modular SIMATIC Design Special design,

More information

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO

More information

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System - 1 - Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System The DPC 4 welding system offers several features that are intended to communicate with automation. These features

More information

Access Control Keypad for MK-DV, JB-DV

Access Control Keypad for MK-DV, JB-DV #91173 0406 Access Control Keypad for MK-DV, JB-DV - INSTRUCTIONS - The KVI is a surface mount electronic access control keypad for use with Aiphone s MK-DV or JB-DV video door station. Designed with the

More information

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Modular Power System acc. VG MoFess Module for Military Ground Vehicles This new modular Power System for Military Ground Vehicles based on a standard box incorporating up to three different power modules. The power inlet module (230 V AC) includes line filter, lightning protection

More information

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1. Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options

More information

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview. .1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA,

More information

Systems Pow-R Breakers Renewal Parts and Accessories

Systems Pow-R Breakers Renewal Parts and Accessories Systems Pow-R Breakers Renewal Parts and Accessories Renewal Parts RP01301013E Effective February 2006 Supersedes RPD29-890A pages 1 16 dated, March 2000 Cutler-Hammer SPB 100, 65 and 50 Series Contents

More information

Type: DILM12 10(24VDC) Article No.:

Type: DILM12 10(24VDC) Article No.: Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver Accurate IRIG-B Over Fiber Optics Major Features and Benefits The SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver can send high-accuracy demodulated

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information

Preface, Contents. Getting started with LOGO! LOGO! installation and wiring. Programming LOGO! LOGO! functions 4. Configuring LOGO!

Preface, Contents. Getting started with LOGO! LOGO! installation and wiring. Programming LOGO! LOGO! functions 4. Configuring LOGO! Preface, Contents Getting started with LOGO! LOGO! installation and wiring Programming LOGO! 1 2 3 LOGO! functions 4 Configuring LOGO! 5 LOGO! program module (card) 6 LOGO! LOGO! Software 7 Applications

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications. Solenoid s Inline s IV Nominal diameter 3 mm Suitability for Industry-Specific Applications Applications Inline valve for deactivation of unused suction pads Individual control of the suction pads of a

More information

DMX and 4000 air circuit breakers from 800 to 4000 A

DMX and 4000 air circuit breakers from 800 to 4000 A DMX 3 20 and 00 air circuit breakers from 800 to 00 NEW 286 56 + 288 02 (p. 4) 286 4 + 288 02 (p. 4) 28 56 + 288 02 (p. 4) Dimensions (p. to 53) Electrical characteristics (p. 54 to 5) ir circuit breakers

More information

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description Operating Instructions talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls The talento 800 controls are one, two and four electronic time switches with 365-day, 7-day and 24-hour

More information

Directional Couplers and Splitters

Directional Couplers and Splitters Directional couplers and splitters divide trunk and feeder lines. 17-Amp current handling capacity. Excellent hum-modulation performance. 1/2-inch hard-line ports have extra length, creating a better seal

More information

Keyed LC Connector Solution A LANscape Solutions Product

Keyed LC Connector Solution A LANscape Solutions Product Applications Department of Defense installations Secure government facilities Research labs Organizations with a desire to segregate networks due to privacy or security concerns Keyed LC Connector Solution

More information

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram XE0002D August 2005 Modular DAA with 2/4 Wire Convertor Description The XE0002D is a compact DAA module designed for applications requiring voice, data or fax transfer. It complies with FCC Part 68 rules

More information

P-2 Installing the monitor (continued) Carry out as necessary

P-2 Installing the monitor (continued) Carry out as necessary P-2 Installing the monitor (continued) Carry out as necessary Using the monitor without the bezel MDT552S satisfies the UL requirements as long as it is used with the bezel attached. When using the monitor

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19 No. IB028911 Nov. 2016 User s Manual Insulation Resistance Tester TOS7200 1. Preface 11 2. Preparation 14 3. Safety Precautions during Testing 19 4. Basic Operation 23 5. Using Terminals and Connectors

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

Displacement Measuring System for Cylinder Series OSP-P

Displacement Measuring System for Cylinder Series OSP-P -SENSOFLEX Displacement for Cylinder Series OSP-P Overview...112 Technical Data SFI-plus...113 Dimensions SFI-plus...114 Order Information...115 111 Sensoflex - Sensoflex Displacement measuring system

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

Alphanumeric Index. Circuit Breakers Transformers Low-signal PC Board Relays Mid-Range PC Board Relays...

Alphanumeric Index. Circuit Breakers Transformers Low-signal PC Board Relays Mid-Range PC Board Relays... Alphanumeric Index Series Type Page Timer Accessories... 1206 Timer Terms and Definitions... 1204 Timer Timing Modes... 1205 2100... Miniature Electropneumatic Timer... 1254 7000... Electropneumatic Timer...

More information

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8 Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between

More information

Model FS-4608R. Features. Overview

Model FS-4608R. Features. Overview Model FS-4608R Features 8-Channel Active Video Receiver Hub(dual video output) Full-motion color video signal up to 3936ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission

More information

ELECTRONIC MULTI METER

ELECTRONIC MULTI METER PRODUCT CATALOG ELECTRONIC MULTI METER OUTLINE * Most suitable for measuring the monitor of incoming circuit from low-voltage circuit to highvoltage circuit. * Centralized monitoring in line with system

More information

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay Timer and switching relay Timer and switching relays Timers Power-on delayed Power-off delayed Power-on and power-off delayed Switch-on and/or switch-off wiping (pulse shaper) Function timer relay Clock

More information

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H BENESTON USER MANUAL AHD to HDMI & VGA & AV Converter Our AHD to HDMI & VGA & AV Converter is designed to convert one channel AHD video source to HDMI & VGA & AV displays simultaneously. It supports multiple

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39 7.40 5.2 The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3 PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC LTC2280, LTC2282, LTC2284, LTC2286, LTC2287, LTC2288 LTC2289, LTC2290, LTC2291, LTC2292, LTC2293, LTC2294, LTC2295, LTC2296, LTC2297, LTC2298 or LTC2299 DESCRIPTION Demonstration circuit 851 supports a

More information

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

with additional normally-open signalling contact l With integrated AS interface Safety at Work. Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting

More information

Understanding. Here s an examination of high-frequency pathological signal transmission issues in today s high-bandwidth equipment.

Understanding. Here s an examination of high-frequency pathological signal transmission issues in today s high-bandwidth equipment. Understanding Feature blocking capacitor effects Here s an examination of high-frequency pathological signal transmission issues in today s high-bandwidth equipment. By Renaud Lavoie W hy should we do

More information

DPR100 C/D Pen and Multichannel Recorder: Digital Display

DPR100 C/D Pen and Multichannel Recorder: Digital Display Page: DPR-17 DPR100 C/D Pen and Multichannel Recorder: Digital Display Model Selection Guide with Price Data Model Selection Guide 43-DR-16-11 Issue 19 (Ref. 43-DR-16-12) Instructions Select the desired

More information

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians Radio receiver EXL 4-channel / up to 1000 memory locations Mounting and operating instructions for qualified electricians Please keep these instructions so that you have them available if you have any

More information

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A. Cryoelectronics MS-FLL User s Manual Mr. SQUID Flux-Locked Loop STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM 87508 U. S. A. STAR Cryoelectronics, LLC ii Table of Contents Revision Record...

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Automated Local Loop Test System

Automated Local Loop Test System INSTRUMENTS Automated Local Loop Test System Comprehensive Local Loop Testing for Voice, Data, Fax and Internet Services Two-way Testing of Copper, Wireless, and Hybrid-Fiber Coax Local Loops A whole new

More information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance NEW Safety Light Curtain MS4800 Series Strong, Durable Body and Long, 20-m Sensing Distance A Powerful Safety Light Curtain with Durable, Impact-resistant Body and Long, 20-m Sensing Distance Has Arrived.

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

TUBE CONVERTERS EL84. Yellow Jackets Types YJS p. 2 YJSHORT p. 3 YJC p. 3 YJ20 p. 4 YJUNI p. 4 YJ7591 p. 4 YJR p. 5. screen grid 9. control.

TUBE CONVERTERS EL84. Yellow Jackets Types YJS p. 2 YJSHORT p. 3 YJC p. 3 YJ20 p. 4 YJUNI p. 4 YJ7591 p. 4 YJR p. 5. screen grid 9. control. TUBE CONVERTERS Yellow Jackets tube converters allow EL power tubes to be used in place of the most common guitar amp power tubes including L, EL, V, 0, 0 and 9. Most Yellow Jackets provide a substantial

More information

VIP-3/SC/FLK40. Extract from the online catalog. Order No.:

VIP-3/SC/FLK40. Extract from the online catalog. Order No.: Extract from the online catalog VIP-3/SC/FLK40 Order No.: 2315078 VARIOFACE module, with screw connection and flat-ribbon cable plug connector, for mounting on NS 32 or NS 35/7.5, with pin strip and short

More information

canfield connector

canfield connector Effective: 2/15/08 TABLE OF CONTENTS Series 5000 Series 5F Series 5J Series 5FR Series 5JR Series R5000 Series D5400 Series P5600 Series FAC 12mm to DIN Series FAC Auto to DIN Series FAC 12mm cord. to

More information

Altech UL489 Busbar System

Altech UL489 Busbar System Altech UL489 Busbar System ANNEX UL489 Listed Busbars The Altech Busbar System is an innovative way to jumper up to 57 poles of Miniature Molded Case (MMCCB). The advantages of this busbar system are:

More information

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version EM IVERTER TC-DE TC-TE roduct description Emergency lighting supply unit f manual testing F compact fluescent lamps mall dimensions ( x 0 mm cross-section, 0 mm length) -year guarantee roperties h rated

More information

Safety Light Curtain Type4 SIL3 PLe

Safety Light Curtain Type4 SIL3 PLe Maximum safety standard Type4 SIL3 PLe Safety Light Curtain GL-R Series Unmatched Protection! Safety Light Curtain Strong Smart Simple GL-R Series SAFETY LIGHT CURTAINS DESIGNED FOR ANY APPLICATION RECESSED

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC LTC2286, LTC2287, LTC2288, LTC2290, LTC2291, LTC2292, LTC2293, LTC2294, LTC2295, LTC2296, LTC2297, LTC2298 or LTC2299 DESCRIPTION Demonstration circuit 816 supports a family of s. Each assembly features

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

Catalog Numbers Series Single Motor Cables

Catalog Numbers Series Single Motor Cables Types of Cable Flexing Rolling Motion Torsional Twisting Motion Reverse Bending (tic-toc) Motion Catalog Numbers - 2090-Series Single Motor Cables Catalog numbers consist of various characters, each of

More information

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function,

More information

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing) Timer Modules MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing) EMU11 24 Hour Module, EMU17 7 Day Module (With Housing Giving panel mounting facility) Installation & Operating Instructions 1 1.

More information

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor 165 VARIABLE SPEED USER MANUAL Premium Efficiency Variable Speed Motor COPYRIGHT Copyright 2013, Regal Beloit America, Inc. Tipp City, Ohio. All rights reserved. TRADEMARKS All trademarks and registered

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

Indication modules. LED-indication modules. Datasheet

Indication modules. LED-indication modules. Datasheet Indication modules LED-indication modules Compact module in a 96 x 96 mm housing for panel mounting 8 or 16 channels with exchangeable LED s Several alarm voltages in a range from 24 V up to 230 V Integrated

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

ZDC RF Coax Connector Series 50 & 75 Ohm

ZDC RF Coax Connector Series 50 & 75 Ohm CONTACTORS CONNECTORS WIRE & CABLE EMI/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATIO I/RFI FILTERS CIRCUIT BREAKERS HARNESSING & PROTECTION IDENTIFICATION & LABELING PCB & CABLE ASSEMBLIES

More information

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50 2.4GHz Audio / Video Sender System AVS50 USER GUIDE 2.4GHz Audio/Video Sender System CONTENTS 1. Introduction... 2 2. Conformity of Use... 3 3. Controls and Connections... 4-5 4. Product Contents... 6