1 Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also perform an experiment using function generator to measure amplitude, time period and frequency of the time-varying signals using a calibrated cathode ray oscilloscope and to compare the measured values with that of a digital multimeter. PRELAB 1. In the instruction manual look for product descriptions and specifications that are relevant to the instruments used for this lab. EQUIPMENT USED 30 MHz Dual Channel Cathode Ray Oscilloscope 3 MHz Function Generator 4 ½ digit Digital Multimeter BNC Cables and Probes THEORY Introduction The Cathode Ray Oscilloscope (CRO) provides a visual presentation of any waveform applied to the input terminal. The oscilloscope consists of the following major subsystems. Cathode-ray tube(crt) Vertical amplifier Horizontal amplifier Sweep Generator Trigger circuit Associated power supply It can be employed to measure quantities such as peak voltage, frequency, phase difference, pulse width, delay time, rise time and fall time. Cathode Ray Tube (CRT) The CRT is the heart of the CRO providing visual display of an input signal waveform. A CRT contains four basic parts: An electron gun to provide a stream of electrons. Focusing and accelerating elements to produce a well define beam of electrons. Horizontal and vertical deflecting plates to control the path of the electron beam. An evacuated glass envelope with a phosphorescent screen which glows visibly when struck by electron beam Page 1
2 A cathode containing an oxide coating is heated indirectly by a filament resulting in the release of electrons from the cathode surface. The control grid, which has a negative potential, controls the electron flow from the cathode and thus controls the number of electron directed to the screen. Once the electron passes the control grid, they are focused into a tight beam and accelerated to a higher velocity by focusing and accelerating anodes. The high velocity and well-defined electron beam then passed through two sets of deflection plates. electron gun Y plates cathod anode electron beam fluorescent screen X plates Basic construction of CRT The first set of plates is oriented to deflect the electron beam vertically. The angle of the vertical deflection is determined by the voltage polarity applied to the deflection plates. The electron beam is also being deflected horizontally by a voltage applied to the horizontal deflection plates. The tube sensitivity to deflecting voltages can be expressed in two ways that are deflection factor and deflection sensitivity. The deflected beam is then further accelerated by very high voltages applied to the tube with the beam finally striking a phosphorescent material on the inside face of the tube. The phosphor glows when struck by the energetic electrons. Control Grid: Regulates the number of electrons that reach the anode and hence the brightness of the spot on the screen. Focusing anode: Ensures that electrons leaving the cathode in slightly different directions are focused down to a narrow beam and all arrive at the same spot on the screen. Electron gun: Cathode, control grid, focusing anode, and accelerating anode. Deflecting plates: An electric field between the first pair of plates deflects the electrons horizontally, and an electric field between the second pair deflects them vertically. If no deflecting fields are present, the electrons travel in a straight line from the hole in the accelerating anode to the center of the screen, where they produce a bright spot. In general-purpose oscilloscopes, amplifier circuits are needed to increase the input signal to the voltage levels required to operate the tube because the signals measured using CRO are typically small. There are amplifier sections for both vertical and horizontal deflection of the beam. Vertical Amplifier: amplify the signal at its input prior to the signal being applied to the vertical deflection plates. Horizontal Amplifier: amplify the signal at its input prior to the signal being applied to the horizontal deflection plates. Sweep Generator: develop a voltage at the horizontal deflection plate that increase linearly with time Page 2
3 Operation The four main parts of the oscilloscope CRT are designed to create and direct an electron beam to a screen to form an image. The oscilloscope links to a circuit that directly connects to the vertical deflection plates while the horizontal plates have linearly increasing charge to form a plot of the circuit voltage over time. In an operating cycle, the heater gives electrons in the cathode enough energy to escape. The electrons are attracted to the accelerating anode and pulled through a control grid that regulates the number of electrons in the beam, a focusing anode that controls the width of the beam, and the accelerating anode itself. The vertical and horizontal deflection plates create electric fields that bend the beam of electrons. The electrons finally hit the fluorescent screen, which absorbs the energy from the electron beam and emits it in the form of light to display an image at the end of the glass tube. Front-panel controls POWER Pushbutton switch to turn scope ON and OFF. LED indicates POWER ON condition 2. INTENS. Intensity control to adjust brightness of CRT screen Page 3
4 3. FOCUS Focus control to adjust Sharpness of CRT display. 4. TR Trace Rotation Pot. Screw driver adjustment for alignment of trace. 5. X POS Controls Horizontal Position of trace. 6. HOLD OFF Controls Hold OFF time between Sweeps in the ratio 1:10 approx. 7. TIME/DIV Selects Timebase speeds from 0.5us/div to 0.2s/div. 8. AT/NORM. Switch in out position: Automatic Triggering (Trace visible without signal) Switch Pressed: Normal Triggering with Level control. (Trace invisible without signal) 9. LEVEL Adjusts trigger point of the signal from +ve peak to ve peak, if at/norm PB switch is pressed 10. X-MAGx10 Switch when pressed magnifies Trace or Signal 10 times in X-direction. 11. CT Switch when pressed converts the instrument from oscilloscope to Component Tester mode. One test lead is connected to CT socket and the second test lead connected to ground socket. 12. Y-POS. Controls Vertical position of CH.I trace 13. INVERT (CH.I) Switch when pressed, inverts the polarity of CH.I signal. In combination with ADD switch, used for algebraic addition or difference of two channels. 14. CH.I Signal input for CH.I 15. GROUND Separate Ground socket 16. AC/DC/GD Input coupling switches for CH.I AC: Both switches in out position. Signal is capacitively coupled, DC is blocked DC: AC/DC switch when pressed, GD switch in out position. All components (AC & DC) of the signal are passed. GD: GD switch pressed. AC/DC switch may be at any position. Signal is disconnected, input of vertical amplifier is grounded. 17. VOLTS/DIV. CH.I Input attenuator. Selects input sensitivity in mv/div or V/div in sequence. 18. DUAL Switch in out position: Single Channel separately. Switch pressed: CH.I & CH.II in alternate mode DUAL + ADD switches pressed: CH.I & CH.II in CHOP mode. 19. ADD Only ADD switch is pressed: Algebraic addition or difference of CH.I & CH.II in combination with INVERT switches. FURTHER READING 1. Paul Horowitz and Winfeld Hill, The Art of Electronics, Cambridge University Press, New York, 2nd edition, The XYZ's of Oscilloscopes, Tektronix, Inc., Beaverton, OR (1992). 3. Patrick C Elliott, The Basics of Digital Multimeters, Ideal Industries, Inc, Page 4
5 PRECAUTIONS Do not leave a bright spot on the screen for any length of time. Do not apply signals that exceed the scope s voltage rating. Do not try to make accurate measurements on signals whose frequency is outside the scope s frequency specifications. Be aware that the scope s input circuitry can cause loading effects on the circuitry under test - Use correct probe for the work. PRACTICE PROCEDURE 1. Measurement using CRO 1. Switch on the CRO. Turn the AC-GND-DC to GND. Check if a horizontal trace appears after the CRO warms up. Set the trace centrally in position on the screen. 2. Become accustomed to the operation of the oscilloscope. Move the focus, intensity, and position controls to see the effects produced. Measurement of Frequency 3. Connect the function generator output to one vertical input of the CRO. 4. Set the function generator in sinusoidal mode and adjust the amplitude of the signal so that it just about fills the screen. 5. Set the signal generator dial at any particular frequency and move the dial until you have only a few complete cycles across the CRO face in the horizontal direction. 6. Measure the period T of the signal. To do so, measure (in divisions & subdivisions) the horizontal distance between two successive peaks and multiply this distance by the reading of the TIME/DIV button which is the scale of the time axis. Record your data. 7. This gives the period T of the AC signal; its frequency is then f = 1/T. Measurement of Voltage 8. Use the volts/div selector to convert vertical readings on the oscilloscope into actual voltages. 9. In measuring the voltage, always measure the value from the center of the trace to its peak. This "peak voltage" is half the peak-to-peak voltage, which is the full height of the trace on the CRO screen. Repeat the above procedure of frequency and voltage measurement for continuous signal, triangular wave and square wave also Page 5
6 OBSERVATION a) Measurement of continuous signal Amplitude, A = V/div = div x _ Period for the waveform, T = _ div x ms/div = _ Frequency, f = 1/T = b) Measurement of sinusoidal signal Amplitude, A = V/div = div x _ Period for the waveform, T = _ div x ms/div = _ Frequency, f = 1/T = c) Measurement of triangular signal Amplitude, A = V/div = div x _ Period for the waveform, T = _ div x ms/div = _ Frequency, f = 1/T = Page 6
7 d) Measurement of rectangular signal Amplitude, A = V/div = div x _ Period for the waveform, T = _ div x ms/div = _ Frequency, f = 1/T = Table 1 S. No Oscilloscope Make: Frequency Specification: _ Waveform Amplitude Time period Frequency on Function generator dial Calculated frequency, f=1/t 1. Continuous signal 2. Sinusoidal signal 3. Triangular signal 4. Rectangular signal Inference Page 7
8 2. Measurements using Digital Multimeter 1. Connect a +4V DC voltage to Oscilloscope and measure the signal with voltage knobs at 1V/div, 2V/div, 5V/div. Also measure the voltage with the DMM in both AC and DC settings. Table 2 Oscilloscope DMM Signal 1V/div 2V/div 5V/div AC Set DC Set + 4V DC - 4V DC Inference 2. Connect a 1 V peak-to-peak sine wave at 1 khz from function generator to oscilloscope. Use the oscilloscope to measure the peak-to-peak voltage of the signal and, hence, calculate the corresponding rms voltage. Now measure with the DMM in AC and DC settings. Table 3 Oscilloscope DMM Signal Vpp (Volts) Vrms (Volts) AC Set DC Set Sine wave 4V, 1 khz Sine wave 4V, 100 khz Sine wave 4V, 1 MHz Page 8
9 Inference UNDERSTANDING & LEARNING Page 9
10 RESULTS AND CONCLUSION POST LAB INFERENCE 1. What is the range of frequency for which Oscilloscope work satisfactorily? 2. Compare the measurements of Oscilloscope with that of the DMM. 3. What are the measurement range, resolution and accuracy of the DMM you used? 4. Over what frequency range will the DMM operate satisfactorily in AC mode? Prepared by: Name: _ Reg. No.: Experiment Date: Report Submission Date: Submission Delay:... Signature Page 10
CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR
CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR OSCILLOSCOPE 3.1 Introduction The cathode ray oscilloscope (CRO) provides a visual presentation of any waveform applied to the input terminal. The oscilloscope
More informationElectrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)
2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency
More informationThe Cathode Ray Tube
Lesson 2 The Cathode Ray Tube The Cathode Ray Oscilloscope Cathode Ray Oscilloscope Controls Uses of C.R.O. Electric Flux Electric Flux Through a Sphere Gauss s Law The Cathode Ray Tube Example 7 on an
More informationUsing an oscilloscope - The Hameg 203-6
Using an oscilloscope - The Hameg 203-6 What does an oscilloscope do? Setting up How does an oscilloscope work? Other oscilloscope controls Connecting a function generator Microphones audio signals and
More informationCATHODE-RAY OSCILLOSCOPE (CRO)
CATHODE-RAY OSCILLOSCOPE (CRO) I N T R O D U C T I O N : The cathode-ray oscilloscope (CRO) is a multipurpose display instrument used for the observation, measurement, and analysis of waveforms by plotting
More informationCHAPTER 4 OSCILLOSCOPES
CHAPTER 4 OSCILLOSCOPES 4.1 Introduction The cathode ray oscilloscope generally referred to as the oscilloscope, is probably the most versatile electrical measuring instrument available. Some of electrical
More informationCATHODE RAY OSCILLOSCOPE (CRO)
CATHODE RAY OSCILLOSCOPE (CRO) 4.6 (a) Cathode rays CORE Describe the production and detection of cathode rays Describe their deflection in electric fields State that the particles emitted in thermionic
More informationCATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency
CATHODE RAY OSCILLOSCOPE Basic block diagrams Principle of operation Measurement of voltage, current and frequency 103 INTRODUCTION: The cathode-ray oscilloscope (CRO) is a multipurpose display instrument
More informationUniversity of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope
University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope Name:, A. Stolp, 2/2/00 rev, 9/15/03 NOTE: This is a fill-in-the-blanks lab. No notebook is required. You are encouraged
More informationCathode Ray Oscilloscope
Lesson: Cathode Ray Oscilloscope Author: Dr. Arijit Chowdhuri College/ Department: Acharya Narendra Dev College, University of Delhi 1 Cathode Ray Oscilloscope (CRO) Introduction During a typical teaching-learning
More informationRICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury
RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury INTC 1307 Instrumentation Test Equipment Teaching Unit 8 Oscilloscopes Unit 8: Oscilloscopes
More informationUniversity of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:
University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope Name:, Lab TA: A. Stolp, 2/2/00 rev, 9/14/00 NOTE: This is a fill-in-the-blanks lab. No notebook is required. You are encouraged
More informationS op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s
ET 150 Scope Controls Learning Objectives In this lesson you will: learn the location and function of oscilloscope controls. see block diagrams of analog and digital oscilloscopes. see how different input
More informationBurlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix
v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc
More informationOPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania
OPERATING INSTRUCTIONS FOR SYLVANIA Type I08 Cathode-Ray Oscilloscope Sylvania Electric Products Inc. Industrial Apparatus Plant Emporium, Pennsylvania OPERATING INSTRUCTIONS FOR Sylvania Type 08 Cathode-Ray
More informationBeginners How to Test DSO138mini
Beginners How to Test DSO138mini You have finished assembling your DSO138mini kit. You may be anxious to see it works. But you might not be familiar with oscilloscope and you could encounter unexpected
More informationExperiment 9A: Magnetism/The Oscilloscope
Experiment 9A: Magnetism/The Oscilloscope (This lab s "write up" is integrated into the answer sheet. You don't need to attach a separate one.) Part I: Magnetism and Coils A. Obtain a neodymium magnet
More informationINSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017
v3 INSTRUCTION GUIDE for the Keysight (formally Agilent; Hewlett-Packard) WAVEFORM GENERATOR Model #33509B 33500 Series and Tektronix OSCILLOSCOPE Model #MSO2004B Fall 2017 Pg. 2 Scope-Gen Handout_part
More informationBME 3512 Biomedical Laboratory Equipment List
BME 3512 Biomedical Laboratory Equipment List Agilent E3630A DC Power Supply Agilent 54622A Digital Oscilloscope Agilent 33120A Function / Waveform Generator APPA 95 Digital Multimeter Component Layout
More informationTHE OPERATION OF A CATHODE RAY TUBE
THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:
More informationTHE OPERATION OF A CATHODE RAY TUBE
THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:
More informationComputer Graphics Hardware
Computer Graphics Hardware Kenneth H. Carpenter Department of Electrical and Computer Engineering Kansas State University January 26, 2001 - February 5, 2004 1 The CRT display The most commonly used type
More informationOscilloscope Guide Tektronix TDS3034B & TDS3052B
Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic
More informationAnalog Oscilloscope Operation Manual
Oscilloscope Analog Oscilloscope Operation Manual Oscilloscope Analog Oscilloscope Operation Manual Safety Summary Safety Precautions Please take a moment to review these safety precautions. They are provided
More informationPhysics 123 Hints and Tips
Physics 123 Hints and Tips Solderless Breadboards All of the analog labs and most of the digital labs will be built on the Proto-Board solderless breadboards. These provide three solderless breadboard
More informationElements of a Television System
1 Elements of a Television System 1 Elements of a Television System The fundamental aim of a television system is to extend the sense of sight beyond its natural limits, along with the sound associated
More informationTutorial Cathode Rays Year 12 Physics - Module 9.3 Motors and Generators
Tutorial 9.4.1.2 Cathode Rays Year 12 Physics - Module 9.3 Motors and Generators For use with Lesson 9.4.1 Cathode Rays 1. Identify the properties of cathode rays that indicated that they might be particles.
More informationThese are used for producing a narrow and sharply focus beam of electrons.
CATHOD RAY TUBE (CRT) A CRT is an electronic tube designed to display electrical data. The basic CRT consists of four major components. 1. Electron Gun 2. Focussing & Accelerating Anodes 3. Horizontal
More informationWAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES New Cover to Come Unmatched Performance, Portability, and Value ALL THE TOOLS YOU NEED Automatic Measurements Save time making measurements on your signals by using the
More informationINSTRUCTION MANUAL Model 2522C. 20 MHz DIGITAL STORAGE/ANALOG OSCILLOSCOPE
INSTRUCTION MANUAL Model 2522C 20 MHz DIGITAL STORAGE/ANALOG OSCILLOSCOPE TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because
More information3B SCIENTIFIC PHYSICS
B SCIENTIFIC PHYSICS Triode S 11 Instruction sheet 1/15 ALF 1 5 7 1 Guide pin Connection pins Cathode plate Heater filament 5 Grid Anode 7 -mm plug for connecting anode 1. Safety instructions Hot cathode
More informationPresented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali. Supervised by: Dr.Mohamed Abd El Ghany
Presented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali Supervised by: Dr.Mohamed Abd El Ghany Analogue Terrestrial TV. No satellite Transmission Digital Satellite TV. Uses satellite
More informationMIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003
MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition
More informationAgilent Technologies 54522A
Agilent Technologies 54522A Data Sheet Product Specifications General Specifications Maximum Sample Rate 54522A 2 GSa/s Number of Channels (all are simultaneous acquisition) 54522A: 2 Record Length 32,768
More informationENJOY YOUR BOOKS PLEASE VISIT OUR STORE FOR EVEN MORE GREAT STUFF! COPYRIGHT NOTICE ALL MATERIALS INCLUDING CD/DVD AND
ENJOY YOUR BOOKS PLEASE VISIT OUR STORE FOR EVEN MORE GREAT STUFF! WWW.EVERYTHING4LESSSTORE.COM COPYRIGHT NOTICE ALL MATERIALS INCLUDING CD/DVD AND PDF FILES ARE COPYRIGHTED WWW.EVERYTHING4LESSSTORE.COM
More informationINSTRUMENT CATHODE-RAY TUBE
Instrument cathode-ray tube D14-363GY/123 INSTRUMENT CATHODE-RAY TUBE mono accelerator 14 cm diagonal rectangular flat face internal graticule low power quick heating cathode high brightness, long-life
More informationWAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES Unmatched Performance, Portability, and Value 1 WAVEJET 300 SERIES Unique Capabilities in a Low Bandwidth Oscilloscope The WaveJet 300 Series features unmatched performance
More informationJ.J. Thomson, Cathode Rays and the Electron
Introduction Experimenters had noticed that sparks travel through rarefied (i.e. low pressure) air since the time of Franklin. The basic setup was to have two metal plates inside a glass tube. The air
More informationPicoScope 6407 Digitizer
YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator
More informationExpect to Make Waves.
Expect to Make Waves. The New Oscilloscope Large 10.4" LCD touch screen Long capture time Extensive communication capabilities www.lecroy.com The New Oscillos From its large 10.4" LCD touch screen to its
More informationTeltron Delection Tube D
Teltron Delection Tube D 1011119 Overview The electron-beam deflection tube is intended for investigating the deflection of electron beams in electrical and magnetic fields. It can be used to estimate
More informationB. TECH. VI SEM. I MID TERM EXAMINATION 2018
B. TECH. VI SEM. I MID TERM EXAMINATION 2018 BRANCH : COMPUTER SCIENCE ENGINEERING ( CSE ) SUBJECT : 6CS4A COMPUTER GRAPHICS & MULTIMEDIA TECHNIQUES Q 1. Write down mid point ellipse drawing algorithm.
More information4.9 BEAM BLANKING AND PULSING OPTIONS
4.9 BEAM BLANKING AND PULSING OPTIONS Beam Blanker BNC DESCRIPTION OF BLANKER CONTROLS Beam Blanker assembly Electron Gun Controls Blanker BNC: An input BNC on one of the 1⅓ CF flanges on the Flange Multiplexer
More informationPicoScope 6407 Digitizer
YE AR HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis
More informationPortable Performance for Debug and Validation
WaveJet 300A Oscilloscopes 100 MHz 500 MHz Portable Performance for Debug and Validation A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES Key Features 100 MHz, 200 MHz, 350 MHz and 500 MHz bandwidths Sample
More informationAgilent DSO5014A Oscilloscope Tutorial
Contents UNIVERSITY OF CALIFORNIA AT BERKELEY College of Engineering Department of Electrical Engineering and Computer Sciences EE105 Lab Experiments Agilent DSO5014A Oscilloscope Tutorial 1 Introduction
More informationFluke /
Fluke 190-104/190-204 ScopeMeter 190 Series II Service Manual PN 4822 872 05405 March 2011 2011 Fluke Corporation, All rights reserved. Printed in the Netherlands All product names are trademarks of their
More informationCR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.
CR7000 CRT Analyzer & Restorer Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security. S1 New Demands From Higher Performance CRTs Require New Analyzing Techniques
More informationINSTRUMENT CATHODE-RAY TUBE
INSTRUMENT CATHODE-RAY TUBE 14 cm diagonal rectangular flat face domed mesh post-deflection acceleration improved spot quality for character readout high precision by internal permanent magnetic correction
More informationMINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure
MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum
More informationActivity P32: Variation of Light Intensity (Light Sensor)
Activity P32: Variation of Light Intensity (Light Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Illuminance P32 Vary Light.DS P54 Light Bulb Intensity P54_BULB.SWS Equipment Needed
More informationScopeMeter 190 Series Specifications
Seite 1 von 7 ScopeMeter 190 Series Specifications Product Home Features Specifications Models, Options & Accessories Oscilloscope Mode Meter Mode Recorder Mode General Specifications Oscilloscope Mode
More informationLeCroy Digital Oscilloscopes
LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,
More informationDigital Storage Oscilloscopes 2550 Series
Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz
More informationME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition
ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods
More informationAnalog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube
TS-81000 DC 1 GHz, 4 CH, 15 traces TS-80600 DC 600 MHz, 4 CH, 15 traces There is the world, only Analog can capture it! State of the art Analog Oscilloscope As technology advanced rapidly, it is getting
More informationTypes of CRT Display Devices. DVST-Direct View Storage Tube
Examples of Computer Graphics Devices: CRT, EGA(Enhanced Graphic Adapter)/CGA/VGA/SVGA monitors, plotters, data matrix, laser printers, Films, flat panel devices, Video Digitizers, scanners, LCD Panels,
More informationWaveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70
Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70 Two instruments combined in one unit PM 5661/70 features Sc-H phase display Input Signal Subtraction (A-B) for easy
More information3B SCIENTIFIC PHYSICS
3B SCIENTIFIC PHYSICS Complete Fine Beam Tube System 1013843 Instruction sheet 10/15 SD/ALF If it is to be expected that safe operation is impossible (e.g., in case of visible damage), the apparatus is
More informationIntroduction to the oscilloscope and digital data acquisition
Introduction to the oscilloscope and digital data acquisition Eric D. Black California Institute of Technology v1.1 There are a certain number of essential tools that are so widely used that every aspiring
More informationTHE OSCILLOSCOPE AND SPECTRUM ANALYZER http://www.infodotinc.com/neets/book16/71.htm Page 1 of 5 Order this information in Print Order this information on CD-ROM D Click here to make tpub.com your Home
More informationQuick Start. RSHS1000 Series Handheld Digital Oscilloscope
Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products
More informationdecodes it along with the normal intensity signal, to determine how to modulate the three colour beams.
Television Television as we know it today has hardly changed much since the 1950 s. Of course there have been improvements in stereo sound and closed captioning and better receivers for example but compared
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications
Analog Arts SA985 SA975 SA935 SA915 Product Specifications Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1]
More informationUser Manual. GPS-1000B+ series. Digital Oscilloscope V 1.1
User Manual GPS-1000B+ series Digital Oscilloscope V 1.1 Brief Introduction Characteristic: The volume of the oscilloscope is cabinet and it is portable 7 Color TFT LCD display 2 channels, Bandwidth:
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications [1]
www.analogarts.com Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1] 1. These models consist of an oscilloscope, a spectrum analyzer, a data recorder, and a frequency & phase meter. Oscilloscope/
More informationProcurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS
र य गक स थ न प द र न ह नगर, क र ल 609 605 NATIONAL INSTITUTE OF TECHNOLOGY PUDUCHERRY Nehru Nagar, Karaikal 609 605 NIQ No.: NITPY / 015-16/ECE/ DE & CE LAB / Q00 Date: 05-0-016 NOTICE INVITING QUOTATION
More informationRIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationEMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C
A Electric Power / Controls 2 kw EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C GENERAL DESCRIPTION The Lab-Volt Data Acquisition and Management for Electromechanical Systems (LVDAM-EMS),
More informationTHE CATHODE -RAY OSCILLOSCOPE
THE CATHODE -RAY OSCILLOSCOPE %ssok RRT -20 2533 N. Ashland Ave., Chicago 14, Illinois Radio Reception and Transmission LESSON RRT -20 THE CATHODE -RAY OSCILLOSCOPE CHRONOLOGICAL HISTORY OF RADIO AND
More informationPAST EXAM PAPER & MEMO N3 ABOUT THE QUESTION PAPERS:
EKURHULENI TECH COLLEGE. No. 3 Mogale Square, Krugersdorp. Website: www. ekurhulenitech.co.za Email: info@ekurhulenitech.co.za TEL: 011 040 7343 CELL: 073 770 3028/060 715 4529 PAST EXAM PAPER & MEMO N3
More informationSMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.
9310A Family Digital Oscilloscopes 400 MHz Bandwidth, 100 MS/s Main Features Two and Four Channel Versions 50k, 200k and 1M Point Records DOS Compatible Floppy Disk, PCMCIA portable hard drive and Memory
More informationFluke 19xB-19xC-2x5C. Service Manual. ScopeMeter. models 192B,196B,199B,192C,196C,199C,215C,225C
Fluke 19xB-19xC-2x5C ScopeMeter models 192B,196B,199B,192C,196C,199C,215C,225C Service Manual PN 4822 872 05391 September 2002, rev.2, Oct.09 2002-2009 Fluke Corporation, All rights reserved. All product
More informationUser Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD
User Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD Declaration Copyright by SIGLENT TECHNOLOGIES CO,.LTD. All rights reserved. Contents in this Manual are
More informationDIGITAL OSCILLOSCOPES & DIGITAL SCOPES
7050/7050/70505/7055 Digital Oscilloscopes DL540/DL540L/DL50/DL50L FUNCTIONS SIGL OBSERVATION USING LONG MEMORY Capturing Signals Using Long Memory for Accurate Waveforms The DL50/DL540 can continuously
More informationUser Manual. Digital Oscilloscope V1.9
User Manual Digital Oscilloscope V1.9 Declaration All rights reserved. Contents in this Manual are not allowed to copy, extract and translate before being allowed by the company. Brief Introduction Characteristic:
More informationimso-104 Manual Revised July 19, 2012
imso-104 Manual Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel 2.21 On / Off 2.22
More informationOverview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators
Know Your Oscilloscope Overview Front Panel Sharing Agilent s Resources with Engineering Educators www.educatorscorner.com Horizontal (time) controls Run control Special purpose menus/controls Trigger
More informationCat. No A OWNER'S MANUAL. Please read before using this equipment. WTT oszifox V4.2. for Windows 3.1/95/98
Cat. No. 22-310A OWNER'S MANUAL Please read before using this equipment. WTT oszifox V4.2 for Windows 3.1/95/98 FCC INFORMATION Modifying or tampering with your Wittig oszifox internal components can cause
More informationSep 09, APPLICATION NOTE 1193 Electronic Displays Comparison
Sep 09, 2002 APPLICATION NOTE 1193 Electronic s Comparison Abstract: This note compares advantages and disadvantages of Cathode Ray Tubes, Electro-Luminescent, Flip- Dot, Incandescent Light Bulbs, Liquid
More informationDigitizing Oscilloscopes
Digitizing Oscilloscopes This document is meant to be a reference to the operation of the digitizing oscilloscopes available in the laboratories. Major topics will be covered, but not all the features
More information25 MHz Digital Storage Oscilloscope
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model: 2530B 25 MHz Digital Storage Oscilloscope USER MANUAL Safety Summary The
More informationMP212 Principles of Audio Technology II
MP212 Principles of Audio Technology II Black Box Analysis Workstations Version 2.0, 11/20/06 revised JMC Copyright 2006 Berklee College of Music. All rights reserved. Acrobat Reader 6.0 or higher required
More informationDEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )
DEPARTMENT OF THE ARMY TECHNICAL BULLETIN TB 11-5820-861-35 CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN 5820-00-570-1978) Headquarters, Department of the Army, Washington,
More informationDisplay Devices & its Interfacing
Display Devices & its Interfacing 3 Display systems are available in various technologies such as i) Cathode ray tubes (CRTs), ii) Liquid crystal displays (LCDs), iii) Plasma displays, and iv) Light emitting
More informationINSTRUCTION MANUAL MODEL 5105B. 150MHz (1GS/s) Analog/Digital Oscilloscope
INSTRUCTION MANUAL MODEL 5105B 150MHz (1GS/s) Analog/Digital Oscilloscope TEST INSTRUMENT SAFETY WARNING TEST INSTRUMENT SAFETY Normal use of test equipment exposes you to a certain amount of danger from
More informationPTIK UNNES. Lecture 02. Conceptual Model for Computer Graphics and Graphics Hardware Issues
E3024031 KOMPUTER GRAFIK E3024032 PRAKTIK KOMPUTER GRAFIK PTIK UNNES Lecture 02 Conceptual Model for Computer Graphics and Graphics Hardware Issues 2014 Learning Objectives After carefully listening this
More informationComputer Graphics: Overview of Graphics Systems
Computer Graphics: Overview of Graphics Systems By: A. H. Abdul Hafez Abdul.hafez@hku.edu.tr, 1 Outlines 1. Video Display Devices 2. Flat-panel displays 3. Video controller and Raster-Scan System 4. Coordinate
More informationSDS1000C Specifications
SDS1000C Specifications File Version V1.2 Siglent technology Co., Ltd CHARACTERISTIC: The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 10GSa/s. Memory
More informationHAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes
HAMEG Oscilloscopes Innovation right from the start Without doubt, the oscilloscope is the most important measuring instrument for the characterization of signals in the time domain. HAMEG Instruments
More informationUser's Manual. Rev 1.0
User's Manual Rev 1.0 Digital TV sales have increased dramatically over the past few years while the sales of analog sets are declining precipitously. First quarter of 2005 has brought the greatest volume
More information4CH/2CH Digital Storage Oscilloscopes
Model: 2553, 2555, 2556, 2557, 2558, 2559 4CH/2CH Digital Storage Oscilloscopes USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be
More informationPRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment
Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency
More information2016 RIGOL TECHNOLOGIES, INC.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 9500B Users Supplement Issue: 2 Part Number: 1625019 Issue Date: 9/06 Print Date: October 2005 Page Count: 6 Version 11 This supplement contains information necessary to ensure the accuracy
More informationMeasuring with digital storage oscilloscopes
Markus Reil, Rainer Wagner 2.2016 1MAA265-1e Educational note Measuring with digital storage oscilloscopes Educational note Products: ı R&S HMO1002 This educational note covers the theory and practice
More informationUser Manual SDS1000DL/CNL/CML. Series Digital Oscilloscope V 1.2 SIGLENT TECHNOLOGIES CO,.LTD
User Manual SDS1000DL/CNL/CML Series Digital Oscilloscope V 1.2 SIGLENT TECHNOLOGIES CO,.LTD Declaration Copyright by SIGLENT TECHNOLOGIES CO,.LTD. All rights reserved. Contents in this Manual are not
More informationELECTRICAL ENGINEERING DEPARTMENT California Polytechnic State University
EECTRICA ENGINEERING DEPARTMENT California Polytechnic State University EE 361 NAND ogic Gate, RS Flip-Flop & JK Flip-Flop Pre-lab 7 1. Draw the logic symbol and construct the truth table for a NAND gate.
More informationR2001A/B/C Service Monitor Alignment Sections
R2001A/B/C Service Monitor Alignment Sections R2001A Depot Alignment Notes R2001A Alignment Section A12 FRNT PNL INTERFACE A3 SCOPE/DVM CONTRC)L SINAD IN 3 ( 6 3 1 KHz NOTCH FIL DET»
More informationAn Efficient SOC approach to Design CRT controller on CPLD s
A Monthly Peer Reviewed Open Access International e-journal An Efficient SOC approach to Design CRT controller on CPLD s Abstract: Sudheer Kumar Marsakatla M.tech Student, Department of ECE, ACE Engineering
More information