CHOICECONNECT 100W ENDPOINT OVERVIEW
|
|
- Kathlyn Welch
- 6 years ago
- Views:
Transcription
1 CHOICECONNECT 100W ENDPOINT OVERVIEW
2 ChoiceConnect 100W Solution Benefits 100W
3 ChoiceConnect 100W Solution Benefit Operational Efficiency
4 ChoiceConnect 100 Solution Benefit Customer Engagement USAG E & COST ADVICE CUSTOMER DEVICE
5 ChoiceConnect 100 Solution Benefit System Integrity Conservatio n Reliabilit y
6 ChoiceConnect 100WEndpoint Flexibility of full migration Full two-way communication Time synchronized hourly reads Variable power settings Retains 40 days of hourly data Auto sensing for encoded registers Option for Leak Sensor 20 Year Warranty Advanced diagnostics
7 100W Multiple Power Settings Type High powered endpoint Bubble-Up with Time multiple Power power Output levels Standard SCM Mobile Bubble up 9 second interval 10 dbm (10 mw) Standard SCM Mobile Hard to Read Bubble 21 second interval 27 dbm (500 mw) Up* Data Logging Response 2-way On-demand 27 dbm Fixed Network Bubble Up Standard SCM Fixed Network Bubble Up Network Interval Message (NIM) 60 second interval (see below) 300 second interval (every 5 th bubble up in network mode) 10 dbm 27 dbm * Battery life is affected
8 100W Mobile Datalogging Reads Single Historic Index Reading Move In-Move Out (emimo) Provides a single historical hourly read within the past 40 days 24 Hour string of Hourly Interval Data 40 Days of Daily Index Readings 40 Days of Hourly Interval Data Drive time increased by up to 2X May need to stop momentarily/periodically Acoustic Leak Data from optional Leak Sensor 100W transmits the last 20 days of Leak Sensor data Uploads to mlogonline for analysis
9 ERW W Encoder, Integral Connector ERW W Encoder, Integral Connector for LEAK SENSOR ERW W Encoder, 5 foot cable ERW W Encoder, 5 foot cable for LEAK SENSOR ERW W Encoder, 20 inch cable ERW W Encoder, 20 inch cable for LEAK SENSOR
10 100W Mounting Configurations 60W 100W ½ Rod Mount X X Wall Mount X X Frost Lid/Horizontal Surface Mount X X Shelf Mount X X Through Lid Mount X X Through Lid Remote Antenna X X Pipe Mount X X Direct Meter Mount, Integrated (Badger, AMCO, Hersey) X X
11 100W Direct Mount Elster, Badger, Hersey
12 CHOICECONNECT 100W ENDPOINT DATALOGGING AND TAMPER FEATURES
13 Tampers & Events for 100W Leak Same as 60W Reverse Flow (encoder only) Same as 60W Last Good Read Invalid Read New to 100W Extended Tamper Flag Check Engine Light Low Battery Cut Cable Flag All Tamper events are stored in a tamper log
14 100W vs. 60W Tampers Leak Detection 100W Leak Detection Flag Detection of leak occurring after the meter register Flag is set when the lowest metered amount is repeatedly detected every hour over a 7-day period (168 hours). Flag clears when no additional hourly usage is reported by an encoder or when no pulse is detected by the ERT. Flag is either On or Off Value reported in FDM will be TRUE if a leak is detected (On) and FALSE for no leak (Off). Re-programming returns leak flag to FALSE. 60W Leak Detection Flag Detection of leak occurring after the meter register Flag is set when the lowest metered amount is repeatedly detected every hour over a 7-day period (168 hours). Flag clears when no additional hourly usage is reported by an encoder or when no pulse is detected by the ERT. Flag is either On or Off Value reported in EPL will be a 1 or a 3 if a leak is detected (On) and zero if there is no leak (Off).
15 100W vs. 60W Tampers Reverse Flow 100W Reverse Flow Flag Reverse flow is reported if an hourly index value is less than the previous hourly value. Example: Reading at noon is Reading at 1:00PM is Flag remains enabled for 40 days. The 40-day counter re-starts upon each occurrence of a reverse flow event. Flag is either On or Off In FDM, the flag is set to TRUE if reverse flow is detected (On) After completing a 40-day cycle with no additional reverse flow occurrences the flag returns to FALSE (Off) 60W Reverse Flow Flag Reverse flow is reported if an hourly index value is less than the previous hourly value. Example: Reading at noon is Reading at 1:00PM is Flag remains enabled for 40 days. The 40-day counter re-starts upon each occurrence of a reverse flow event. Flag is either On or Off In EPL, the reverse flow flag is represented by a 2 or a 3 (On) After completing a 40-day cycle with no additional reverse flow occurrences the flag returns to zero (Off)
16 100W vs. 60W Tampers 100W Communication Error Flags Last Good Read Flag Instant Communication Error Invalid Read in FDM Cut Cable Flag Historic Communication Error Extended Tamper 60W Cut Cable Counter A cut cable tamper is reported when the cable connecting the register and endpoint is cut or disconnected. Both cut cable and register/endpoint communication errors increase the counter value if the condition remains unchanged over a 24-hour period. The tamper indicator continues incrementing every 24 hours until the problem is resolved. The counter will increment from
17 New 100W Tampers/Status Last Good Read (LGR) Flag Communication error with the register If this flag is set for 24hrs, then it will initiate Cut Cable Flag in Extended Tampers This flag will automatically clear once a successful read from the register is received Extended Tamper Flag retrievable via 2-way: FDM & MC Low Battery [10% trip level] Cut Cable Flag This flag is set when the LGR flag is on for 24 hours (After 24 consecutive failed read attempts) Cable cut flag stays on for 40 days in mobile mode Cable cut flag stays on for 24 hours in FN mode Meter Right Sizing Complete Commercial application to evaluate proper meter size
18 100W MVRS Datalogging Features MV-RS (Version 8.1) Captures SCM Message Request 2-way Datalogging commands via two methods By designated ERT ID(s) using adhoc request entered in MV- RS user interface Default parameters for all datalogging ERTs by Bill Code Individual options for Residential, Commercial, Industrial and Undefined Review data in table and graphs in MV-RS user interface Export data to IEE/CC using new XML export
19 CHOICECONNECT 100W ENDPOINT OPERATING MODES
20 100W Has Three Standard Operating Modes Factory Mode 100W endpoints are shipped in Factory Mode. The transmitter is turned off. The receiver is enabled every 4 seconds to listen for a programming command. 100W encoder models will attempt to read the register every hour If the 100W reads a connected register, the endpoint automatically moves to Run Mode Run Mode 100W endpoint s normal operation mode. The 100W transmitted message is dependent on its factory settings for standard consumption messages (SCM), or network interval message (NIM) For SCM the 100W default bubble-up rate is 9 seconds. Receiver enabled one second after every SCM. For NIM the 100W bubble-up rate is 5 minutes. When the endpoint is set f NIM th 100W t it ti SCM i t
21 100W Has Three Standard Operating Modes Audit Mode Audit Mode is configured by performing a Check ERT with FDM In Audit Mode the 100W bubble-up rate is faster and the receiver is active. The SCM bubbles up every 4 seconds Receiver is enabled one second after every SCM The 100W exits Audit Mode and enters Run Mode again automatically after 1 hour. NOTE: A Check ERT will not reset tampers. Programming resets tampers AND puts the endpoint in audit mode for 30 days.
22 100W (Encoder) Start-up Routine No shorting plug required 100W auto detects the register type at the top of hour, and then automatically exists the factory mode and enters Run Mode Programming is not required for 100Ws with encoders to initiate Run Mode Leak Sensor is automatically detected if present ERT validation test using Check ERT is strongly suggested to verify everything is working properly after installation. It generates an immediate read from the register It aligns the 100W s time to the reader s current time. Checks communication with Leak Sensor Checks for tampers Note Important to keep HH/Mobile Reader s time current (periodically dock or cradle)!
23 Thank you
Application Note 11 - Totalization
Application Note 11 - Totalization Using the TrendView Recorders for Totalization The totalization function is normally associated with flow monitoring applications, where the input to the recorder would
More informationCELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents
F. S. BRAINARD & COMPANY PO Box 366, 5 Terri Lane Unit 15, Burlington, NJ 08016 tel: (609) 387-4300 fax: (609) 387-4304 www.meter-master.com email: cellosupport@meter-master.com CELLO SETUP WITH WinGPS
More informationOPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.
OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE Engine Vision Introduction Introduction Caterpillar Engine Vision System displays
More informationNT-9600 Wireless Barcode Scanner. Introduction
Guangzhou Netum Electronic Technology Co., Ltd TEL: +86 20 82679969*816 FAX: +86 20 82684887 E-mail: scottchiu@gzxlscan.com Address: Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District,
More informationAmerican DJ. Show Designer. Software Revision 2.08
American DJ Show Designer Software Revision 2.08 American DJ 4295 Charter Street Los Angeles, CA 90058 USA E-mail: support@ameriandj.com Web: www.americandj.com OVERVIEW Show Designer is a new lighting
More informationRotary Knife Controller
PCM-22 Rotary Knife Controller Information furnished by EMERSON Motion Control is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON Motion Control for its use. EMERSON
More informationSPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations
Lucent Technologies Bell Labs Innovations SPIRIT Communications System SPIRIT Attendant User s Guide Lucent Technologies formerly the communications systems and technology units of AT&T 518-453-710 106449697
More informationVLT AutomationDrive FC 301/FC 302
Introduction The can be used as feedback source for closed-loop control or as master source for synchronizing control. Configure the encoder option in parameter group 17-** Feedback Option, see the VLT
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationEN Wireless programmable thermostat
EN Wireless programmable thermostat Contents 1. Installation... 31 2. Description... 32 EN 3. Wireless association... 33 4. Configuration... 34 CF01 - Correcting the temperature measured... 34 CF02 - Temperature
More informationAdditional instructions Memograph M, RSG45 Advanced Data Manager
BA01337R/09/en/01.15 71302215 Firmware version ENU000A, V02.00.xx Products Solutions Services Additional instructions Memograph M, RSG45 Advanced Data Manager Option of wastewater + RSB (rain spillway
More informationMTL Software. Overview
MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL
More informationOcean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff
Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that
More informationStevens SatComm FAQs For use with SatCommSet or Terminal Setup programs
Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs Q. What are the channel assignments for On Air Test Mode? A. The assigned GOES test channels are as follows: GOES West 300 Baud:
More informationEXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide
EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide Introduction The EXA Series of Instruments (EXA PH200, PH400, PH202, PH402) provide much more than just a measurement. They are also
More informationDesigning Intelligence into Commutation Encoders
I Designing Intelligence into Commutation Encoders By: Jeff Smoot, CUI Inc C U I NC Encoder users traditionally have been reluctant to change with good reason. Motor control on the factory floor or in
More informationInstalling the Scotchloks
Chapter 5: Pit Installation Installing the Scotchloks Complete the following steps to install the Scotchloks. 1. Complete steps outlined in "L900 MIU Pit Installation" on page 25 to install the L900 MIU
More informationDatasheet. airmax ac CPE with Dedicated Management Radio. Model: LBE-5AC-Gen2. Lightweight, Low-Cost Solution. Full Adjustment Flexibility
airmax ac CPE with Dedicated Management Radio Model: LBE-5AC-Gen2 Lightweight, Low-Cost Solution Full Adjustment Flexibility Quick Assembly and Installation Overview Ubiquiti Networks launches the latest
More informationVorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)
Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections
More informationInstallation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions
Installation & Operation Manual BEC PM1 Controller Time/Flow/Volume Controller Water Control Solutions Table of Contents Introduction 4 Chapter 1 Technical Data and I/O Connections 6 DC Solenoid 6 Power
More informationThis document contains the latest information about the new Polycom VS4000 TM model, running 5.1 software.
This document contains the latest information about the new Polycom VS4000 TM model, running 5.1 software. What s New? The VS4000 is now available in a compact form factor, making it even easier to integrate
More informationController, Scheduler-Timer Model UCS-01 version User Guide
Model UCS-01 version 1.48+ User Guide QUICK REFERENCE GUIDE Time Date IDLE SCREEN 03:50PM [RUN] 05/09/06 Tue Day of the Week Schedule Mode (change via 'Set Time') [OFF] = No Events Operate [RUN] = Run
More information4X1 Gefen TV Switcher GTV-HDMI N. User Manual
4X1 Gefen TV Switcher GTV-HDMI1.3-441N User Manual INTRODUCTION Congratulations on your purchase of the 4x1 GefenTV Switcher. Your complete satisfaction is very important to us. GefenTV GefenTV is a unique
More informationRain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components
Rain+Birdt Landscape Irrigation & Maintenance Remote System Quick Start Guide 4.00 D System Components A Transmitter (TX) B Receiver (RX) C Quick Connect (QC) 6-Pin Quick Connect (QC) for use with ESP-Modular
More informationShow Designer 3. Software Revision 1.15
Show Designer 3 Software Revision 1.15 OVERVIEW... 1 REAR PANEL CONNECTIONS... 1 TOP PANEL... 2 MENU AND SETUP FUNCTIONS... 3 CHOOSE FIXTURES... 3 PATCH FIXTURES... 3 PATCH CONVENTIONAL DIMMERS... 4 COPY
More informationDS-7200HVI/HFI-SH Series DVR Quick Operation Guide
DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is
More informationDigital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE
Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE Table of Contents GETTING STARTED DESCRIPTION Display Mechanical Electrical Mounting Programmable Settings Default Factory Settings PARTS
More informationVNS2200 Amplifier & Controller Installation Guide
VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationMicro/Junior/Pro PL7 Micro PLC Functions Upcounting. TLX DS 37 PL7 40E engv4
Micro/Junior/Pro PL7 Micro PLC Functions Upcounting TLX DS 37 PL7 40E engv4 35002668 00 2 Related Documentation Related Documentation Introduction This manual is in 2 volumes: l Volume 1 l Common application
More informationSample BD Tech Concepts LLC
XYZ Corp. Fry Controller FC-1234 Software Test Procedure Copyright 2014 Brian Dunn BD Tech Concepts LLC Last Modified: 00/00/0000 Version Tested: Date Tested: Technician: Results: 1 FC-1234 SW Test Proc.
More informationAny feature not specifically noted as supported is not supported.
Manufacturer: ELAN Integration Note Model Number(s): EL-4KM-VW44 (Device Ver 2.20; Web Module Ver 6.23) Minimum Core Module Version: Document Revision Date: 8.1.395 5/11/2017 OVERVIEW AND SUPPORTED FEATURES
More informationPiMPro Rack Mount Analyzer
DATA SHEET Highly accurate 19 inch rack mount PIM Analyzer provides two 40 watt carriers (40W x 2), with -125 dbm sensitivity all in a less than 36 pound carry-on size case Instantaneous Measurement Modes
More informationNoise Detector ND-1 Operating Manual
Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation
More informationR4 AIS Class B Transponder
Saab TransponderTech R4 AIS Class B Transponder Configuration Manual GENERAL Page 1 i Copyright The entire contents of this manual and its appendices, including any future updates and modifications, shall
More informationModel 1476-C SuperQuad HR
Model 1476-C SuperQuad HR Installation and Operating Instructions Table of Contents Page Table of Content... 2 System Description... 3 Features... 3 Installation... 4 Internal Setups... 4 Connections...
More informationTV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR
INSTRUCTION MANUAL Features of the new DVB-C transmodulators line Through the use of the FPGA technology the transmodulators provides the highest performance at the lowest price. Four carriers are formed
More informationIntroduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3
MoTeC MDD User Manual Contents Introduction... 1 Display...1 Mounting...1 Firmware Version...2 ADL Operation... 3 1. Full ADL Display...4 2. Gain Loss Layout for ADL...6 3. Large Numeric Layout for ADL...8
More informationUser Manual K.M.E. Dante Module
User Manual K.M.E. Dante Module Index 1. General Information regarding the K.M.E. Dante Module... 1 1.1 Stream Processing... 1 1.2 Recommended Setup Method... 1 1.3 Hints about Switches in a Dante network...
More informationSport-TIMER 3000 TM Instruction Manual
Sport-TIMER 3000 TM Instruction Manual Sport-TIMER 3000 TM Index of Uses Page Sport-TIMER 3000 TM RECORD OF PURCHASE The Sport-TIMER 3000 TM is fully warranted to the original purchaser against any defects
More informationInstallation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters
Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Written By: Colin Langridge Issue: Draft Date: 03 rd July 2008 1 Date: 29 th July 2008 2 Date: 20 th August 2008 3 Date: 02 nd
More informationPulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)
PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator) Submeter Solutions, Inc. PulseFlow FP100 Submeter Solutions, Inc., 800-64METER Page 1 Table of Contents: Installation
More informationB. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.
VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems
More informationQuick Operation Guide of LTN7700/7600 Series NVR
Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
More informationSONARtrac Technical Bulletin
Page 1 of 14 Purpose: The purpose of this document is to formally release the SONARtrac TM Troubleshooting. The guide lists problems that may be encountered by personnel installing SONARtrac TM meters
More informationFeatures of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator
20 Channel Digital Delay Generator Features of the 745T-20C: 20 Independent delay channels - 100 ps resolution - 25 ps rms jitter - 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every
More informationHDMI Expander Family EP-HC0408 EP-HC046
HDMI Expander Family EP-HC0408 EP-HC046 EP-HC0408/EP-HC0416 User Manual Version 1.0 Last Updated: March 2008 Table of Content 3 Notice 4 Package Content 5 Product Introduction 5 Product Features 6 Panel
More informationFOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)
FOTS100 User Manual BIOPAC Systems, Inc. 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066, Fax (805) 685-0067 WWW.BIOPAC.COM 1 WARRANTY All products manufactured by Opsens inc. are warranted to be free
More informationMicrowave Counter, Power Meter and DVM in One Portable Package
Agilent 53140 Series Microwave Counter, Power Meter and DVM in One Portable Package Product Overview Everything you need for the installation and maintenance of microwave links: A choice of frequency counter
More informationAPM CALIBRATION PROCEDURE Rev. A June 3, 2015
APM CALIBRATION PROCEDURE Rev. A June 3, 2015 Calibration of the APM allows system parameters such as coupler coupling values, interconnecting cable losses and system feeder losses to be programmed into
More informationPart No. ENC-LAB01 Users Manual Introduction EncoderLAB
PCA Incremental Encoder Laboratory For Testing and Simulating Incremental Encoder signals Part No. ENC-LAB01 Users Manual The Encoder Laboratory combines into the one housing and updates two separate encoder
More informationChapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle
Chapter 2: Scanner Operations This chapter explains general Scanner operations and offers instructions for customizing certain Scanner functions. The following is an outline of basic Scanner operation.
More informationProduct Information. EIB 700 Series External Interface Box
Product Information EIB 700 Series External Interface Box June 2013 EIB 700 Series The EIB 700 units are external interface boxes for precise position measurement. They are ideal for inspection stations
More informationIn-Line or 75 Ohm In-Line
or 5 Ohm 1dB Adjustable Gain 800/1900 Smart Technology Contents: Quick Install Overview.... 2 Installation Diagram.... Understanding the Lights... 9 Warnings and Recommendations....11 Appearance of device
More informationMaster Time Clock MTC Users Manual
Master Time Clock MTC-6000 Users Manual Midwest Time Control Phone (972)987-4408 Toll Free (888)713-0373 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL
More informationTroubleshooting CS800/LC900 Bikes
Troubleshooting CS800/LC900 Bikes CS800/900LC Bike Troubleshooting Entering the Maintenance Mode 15 Touch Screen: The Maintenance Mode is designed to help the tech determine certain faults in the upper
More informationMover Beam 7 CKU (US) / CKE (EU) USER MANUAL
Mover Beam 7 CKU01-5030 (US) / CKE01-5030 (EU) USER MANUAL Introduction Thank you for purchasing the ColorKey Mover Beam 7. Please read these instructions carefully before use. Operating this fixture according
More informationOwner s Manual. Sat-Meter MSK 15. Order No.:
Owner s Manual Sat-Meter MSK 15 Order No.: 217 100 13 Thank you for choosing our latest and most innovative satellite meter. It has been designed and manufactured to a very high standard and offers a UNIQUE
More informationOwner s Manual DRR-2T. Dual Tuner DAB+/FM Digital Radio Tuner Digitalview Australia
Owner s Manual DRR-2T Dual Tuner DAB+/FM Digital Radio Tuner 2009-2010 Digitalview Australia Table of Contents IMPORTANT SAFETY INSTRUCTIONS...4 Introduction...1 Features of the DRR-2T...2 User Convenience
More informationTechnical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options
More informationDSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.
DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,
More informationGetting started with
Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial premises OVERVIEW: The OWL Intuition-e electricity monitoring system comprises of three
More informationMulticom Optical Return Path Receiver MUL HRPR 4B
Multicom Optical Return Path Receiver User Manual v.9 www.multicominc.com 800 423 2594 407 331 7779 1076 Florida Central Parkway, Longwood, FL 32750 SAFETY NOTIFICATION Multicom strongly advises you to
More informationDLC SPY maintainance tool User manual
DLC SPY maintainance tool 2 / 11 CONTENTS 1. Quick Start... 4 1.1. Check the list of supplied items... 4 1.2. Connect DLC SPY tool with LV connecting cables and testing nibs... 5 1.3. Connect PDA device
More informationKramer Electronics, Ltd. USER MANUAL. Models: VS-626, 6x6 Video / Audio Matrix Switcher VS-828, 8x8 Video / Audio Matrix Switcher
Kramer Electronics, Ltd. USER MANUAL Models: VS-626, 6x6 Video / Audio Matrix Switcher VS-828, 8x8 Video / Audio Matrix Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1
More informationEncoders - Measuring rotation of a wheel or
Encoders - Measuring rotation of a wheel or other shaft Encoders are devices for measuring the rotation of a spinning shaft. Encoders are typically used to measure the distance a wheel has turned which
More informationDICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating
/A Electronic Signal Data Logger Contents: Product Applications and Useful Features Product Transmitter / DicksonWare Software Product Frequently Asked Questions Warranty / Software & FAQs & Product Applications
More informationINSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE
210 South Third Street North Wales, PA USA 19454 (T) 215-699-2060 (F) 215-699-2061 INSTRUCTION MANUAL FOR LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE i TO THE CUSTOMER Thank you for purchasing this
More informationSNG-2150C User s Guide
SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120
More informationMultiMode FOMs -ST and -SMA
FEBRUARY 1996 MD640A-ST-R2 MD640A-SMA-R2 MD640AE-ST-R2 MD640AE-SMA-R2 MultiMode FOMs -ST and -SMA POWER TD RD RTS CD MultiMode FOM Test Modes Remote Normal Local CUSTOMER SUPPORT INFORMATION Order toll-free
More informationVNS2210 Amplifier & Controller Installation Guide
VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation 1. Determine the installation location for the VNS2210 device. Consider the following when determining the
More informationGWL/ Power Group Technology Solutions Stay Powered for the Future
GWL/ Power Group Technology Solutions Stay Powered for the Future BMS2405 CONNECTION GUIDE: This is simple step-by-step manual how to CONNECT AND proceed basic SETUP of BMS2405. In following example connection
More informationEdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY
EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY 493456301 Rev B April 2009 Table of Contents Installation... 1 Setup... 2 Operation... 4 Live Video... 4 Video Settings... 5 Network
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com OPERATION MANUAL. The Best Thing on Cable
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com OPERATION MANUAL The Best Thing on Cable Table of Contents INDEX I General Information Introduction... 3 Features: RSVP 2
More informationGFT Channel Digital Delay Generator
Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three
More informationAPPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.
TM COMSPHERE 3900 Series Modems Models 3910 and 3911 Government Requirements for Great Britain Document Number 3910-A2-GK42-10 November 1996 Overview This document highlights government requirements, safety
More informationUser Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.
EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended
More informationFRQM-2 Frequency Counter & RF Multimeter
FRQM-2 Frequency Counter & RF Multimeter Usage Instructions Firmware v2.09 Copyright 2007-2011 by ASPiSYS Ltd. Distributed by: ASPiSYS Ltd. P.O.Box 14386, Athens 11510 (http://www.aspisys.com) Tel. (+30)
More informationGrid Interactive Advanced Features Self-Supply Mode
Grid Interactive Advanced Features Self-Supply Mode CHILICON POWER MICROINVERTERS AND CP-100 CORTEX GATEWAY SYSTEM OVERVIEW Chilicon Power Advanced Inverter functions Power Factor Control: -0.8 to +0.8
More informationHD-CM HORIZON DIGITAL CABLE METER
HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279
More informationD-Lab & D-Lab Control Plan. Measure. Analyse. User Manual
D-Lab & D-Lab Control Plan. Measure. Analyse User Manual Valid for D-Lab Versions 2.0 and 2.1 September 2011 Contents Contents 1 Initial Steps... 6 1.1 Scope of Supply... 6 1.1.1 Optional Upgrades... 6
More informationThe measurements are stored in non-volatile memory, which retains data even when the power down.
Data Sheet: DSTAR.545.R1.ENG www.aep.it FAST Professional Handheld Indicator Dynamicstar is an professional indicator, ergonomic, extremely versatile and simple to use for measures FORCE, WEIGHT, PRESSURE,
More informationRA-RS232, RB-RS232. Setup and Installation Guide Addendum For RadioRA RS232 Interface
RA-RS232, RB-RS232 Setup and Installation Guide Addendum For RadioRA RS232 Interface A Comprehensive Step-by-Step Guide for Programming and Operating the Lutron RadioRA RS232 Interface Note: Please leave
More informationWireless Multi-Format input Transmitter to HDMI Receiver Box ID # 718
Wireless Multi-Format input Transmitter to HDMI Receiver Box ID # 718 Operation Manual Introduction The wireless HDMI transmitter and receiver boxes use baseband technology with Wireless High Definition
More informationAES-404 Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com
More informationPiMPro Portable Analyzer PiMPro Classic 1821
DATA SHEET Highly accurate portable PIM Analyzer provides two 40 watt carriers (40W x 2), with -125 dbm sensitivity all in a less than 36 pound carry-on size case Instantaneous Measurement Modes for PIM
More informationJAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit
JAMAR TRAX RD The TRAX RD is an automatic traffic recorder designed and built by JAMAR Technologies, Inc. Since the unit is a Raw Data unit, it records a time stamp of every sensor hit that occurs during
More informationAW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems
User s Manual Point-to-multipoint Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems User s Manual Non-line-of-sight :: 900 MHz Thank you for your purchase of the multipoint
More informationAUTOMATIC VIDEO LOSS A/B SWITCH
CG-X AUTOMATIC VIDEO LOSS A/B SWITCH INSTRUCTION BOOK IB647502 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 3 HOW TO CABLE THE CG-X 3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE AND MAINTENANCE
More informationOccupEye User Manual. Region 1 Revision 1.0
OccupEye User Manual Region 1 Revision 1.0 Contents Contents... 2 Introduction... 3 Commissioning... 4 Operation... 5 Support... 6 FCC Warning Statement... 7 OccupEye Page 2 of 8 Introduction OccupEye
More informationDP C18.UART CONTENT CONTENT. Content 1. Normal indication area 6. Button definition 7. Introduction 2. Normal operation 7. Overview drawing 3
CONTENT DP C18.UART CONTENT Content 1 Introduction 2 Overview drawing 3 Specifications 4 Functional overview 5 Normal indication area 6 Button definition 7 Normal operation 7 User set 10 Error code definition
More informationD-901 PC SOFTWARE Version 3
INSTRUCTION MANUAL D-901 PC SOFTWARE Version 3 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
More informationLogic Design. Flip Flops, Registers and Counters
Logic Design Flip Flops, Registers and Counters Introduction Combinational circuits: value of each output depends only on the values of inputs Sequential Circuits: values of outputs depend on inputs and
More informationInterview Management System Installation Guide
Technical Support Interview Management System Installation Guide www.casecracker.com support@casecracker.com (720) 442-7072 Technologies 2017 (v.15) 1 Equipment Checklist Box 1 Box 2 Box 3 (Optional) CaseCracker
More informationOperation/Reference Guide IRIS. Infrared/Serial Data Capture Unit. Control System Accessories
Operation/Reference Guide IRIS Infrared/Serial Data Capture Unit Control System Accessories Last Revised: 1/17/2007 AMX Limited Warranty and Disclaimer All products returned to AMX require a Return Material
More informationLAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection
LAN Network Tester Part No. 157011 Operating Manual TRIAX - your ultimate connection Safety and Disposal The LAN Network Tester operates off 6V DC only. Only use the internal, battery powered, 6V power
More information800 Displaying Series Flowmeter
TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially
More informationData Acquisition Networks. Installing and Configuring the DM01 Hardware
Data Acquisition Networks Installing and Configuring the DM Hardware What is the DM? D.A.N developed the DM-2 to capture 6 analogue measurements and pulse count in the field. The Average, Maximum and Minimum
More informationInstallation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors
Mechanical Electrical Optical Cat No. Strobing Models COS Models Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors Polarized Retroreflective Retroreflective Standard Diffuse
More informationAM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2
AM-4 Audio Monitor Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 (416) 293-1042 1-888-293-1071 www.videoquip.com AM-4 4 channel Analog, AES3 Digital, SDI
More information