Liquid Level Sensor Type AKS 4100/4100U

Size: px
Start display at page:

Download "Liquid Level Sensor Type AKS 4100/4100U"

Transcription

1 Data sheet Liquid Level Sensor Type /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sensor is designed specifically measure liquid levels in a wide range of refrigeration applications. The /4100U liquid level sensor is based on a proven techhology called Time Domain Reflecmetry (TDR) or Guided Micro Wave. /4100U liquid level sensor can be used measure the liquid level of many different refrigerants in vessels, accumulars, receivers, standpipes, etc. The electrical output is a 2-wired, loop powered 4 20 ma output signal, which is proportional the refrigerant liquid level. /4100U in a cable version is suitable for HCFC, Non flammable HFC and R717 (Ammonia), and differing lengths from 800 mm / 31.5 in. and up 5000 mm / 197 in.. The coaxial version of /4100U is designed for use with R744 (CO 2), HCFC, Non flammable HFC and R717 (Ammonia). The /4100U coaxial version should always be used for marine applications for all refrigerant types. The /4100U cable version should NOT be used for CO 2 or marine applications. Dust, foam, vapour, agitated surfaces, boiling surfaces, changes in density or in the dielectric constant, εr, for the liquid have no influence on the /4100U performance. Oil accumulated in the botm of a standpipe will not disturb the liquid level signal and it is not necessary remove /4100U for cleaning after oil has been drained out of the standpipe. Features Approved and qualified by Danfoss for refrigeration applications One product covering several probe lengths (cable version) A single product for all commonly used refrigerants (cable version) Cable version requires less p-end clearance for installation and service Proven operation with all refrigerants in combination with oil. No need clean cable version when fully covered by oil. The cable version is very compact and easy handle, ship, install and use with different lengths and refrigerants Changes of the liquid dielectric constant (εr) do not affect operation mm / 197 in. probe length with cable version 2-wire loop powered; no separate transformer needed. Please Note: /4100U can be connected directly Danfoss EKE 347 liquid level controller and thus be powered from EKE 347. If used gether with Danfoss EKC 347 liquid level controller, a V DC supply is required. Multi language HMI. Level and setting readout in mm,cm,m (ft, in.) Language HMI versions: - English (default), German, French, Spanish - English (default),japanese, Chinese Russian For further details regarding mechanical and electrical installation please refer the product installation guides DKRCI.PI.SC0.D (CABLE version), DKRCI.PI.SC0.E (COAXIAL D14 version) and DKRCI.PI.SC0.H1/DKRCI.PI.SC0.J1 (COAXIAL D22 version). DKRCI.PD.SC0.F H5687 1

2 Data sheet Liquid Level Sensor, type /4100U Contents Page Features...1 Product concept...3 CABLE version...3 COAXIAL D14 version...3 COAXIAL D22 version...3 Optional HMI...5 Measuring principle...6 Main technical data...6 Measuring range of /4100U: CABLE version...7 COAXIAL D14 version...8 COAXIAL D22 version...8 Ordering /4100U...9 Dimensions and weights Technical data Quick setup: CABLE version COAXIAL version Forcing ma output Entering refrigerant dielectric gas constant Saturated vapour dielectric constant How change the language setting (Default: English) Reset facry setting DKRCI.PD.SC0.F H5687 2

3 Data sheet Liquid Level Sensor, type /4100U Product concept /4100U is available in two different versions: Cable version Coaxial version Both Cable and Coaxial versions are available with two different mechanical process connections: : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT CABLE version: COAXIAL D14 version: COAXIAL D22 version: D22 marking Cable version Cable version The cable version consists of: Signal converter, which can be supplied with or without HMI Mechanical process connection with 5 m / 197 in., Ø2 mm / 0.08 in. stainless cable Counterweight Accessory bag comprising: 3 mm set screws Red cover protect mechanical process connection prior mounting signal converter. Setting label. /4100U cable version must ALWAYS be installed in a standpipe. With the cable version it is possible adapt the /4100U any possible length in the range of 800 mm / 31.5 in mm / in. Cable version can be used in R717 / NH 3, HCFC and HFC (εr, liquid > 5.6). DKRCI.PD.SC0.F H5687 3

4 Data sheet Liquid Level Sensor, type /4100U Coaxial version Coaxial D14 version (see page 3) The Coaxial D14 version consists of: Signal Converter (with or without HMI) Mechanical process connection with 5 m / 197 in., Ø2 mm / 0.08 stainless wire Tube(s) depending on required length Accessory bag comprising: - End Connecr (incl. 3 mm / 0.12 in. set screws.) - 3 mm / 0.12 in. set crews (1 set screw pr. tube) - Red cover protect mechanical process connection, before Signal Converter is mounted. - Setting label. Coaxial D22 version (see page 3) The Coaxial D22 version consists of: Signal Converter (with or without HMI) Mechanical process connection 280 mm / 11 in.,. 8 mm / 0.3 in. inner rod. /4100U, Coaxial can be installed in a standpipe (a) or directly in a vessel (b). a b The coaxial version is mandary for use in: - R744 / CO 2 (εr, liquid > 1.3). - Marine applications The coaxial version can also be used in the refrigerants: R717 / NH 3, HCFC and HFC. The coaxial version is available in the following probe lengths: Danfoss type Tube diameter Type selection in HMI Thread, 280 mm 22 mm 0.87 in. D22 G1 in. pipe thread, 500 mm 14 mm in. D14 G1 in. pipe thread, 800 mm 14 mm 0.55 in. D14 G1 in. pipe thread, 1000 mm 14 mm 0.55 in. D14 G1 in. pipe thread, 1200 mm 14 mm 0.55 in. D14 G1 in. pipe thread, 1500 mm 14 mm 0.55 in. D14 G1 in. pipe thread, 1700 mm 14 mm 0.55 in. D14 G1 in. pipe thread, 2200 mm 14 mm 0.55 in. D14 G1 in. pipe thread U, 11.0 in. 22 mm 0.87 in. D22 ¾ in. NPT U, 19.2 in. 14 mm 0.55 in. D14 ¾ in. NPT U, 30 in. 14 mm 0.55 in. D14 ¾ in. NPT U, 45 in. 14 mm 0.55 in. D14 ¾ in. NPT U, 55 in. 14 mm 0.55 in. D14 ¾ in. NPT U, 65 in. 14 mm 0.55 in. D14 ¾ in. NPT U, 85 in. 14 mm 0.55 in. D14 ¾ in. NPT DKRCI.PD.SC0.F H5687 4

5 Data sheet Liquid Level Sensor, type /4100U Optional HMI The optional HMI Service/Display unit is used for commissioning and quick on-site setup and is easily mounted on the /4100U. The service unit supports mulitple languages in both SI and US units. Supported standard languages: English (default), German, French, Spanish, Japanese, Chinese and Russian. Enter menu system Enter QUICK SETUP Unit change at distance/level readout: m, cm, mm, in, ft * DISTANCE is a display option. If the display is set DISTANCE the displayed value will be the distance from the Reference point the p surface of the liquid refrigerant (see pages 7 and 8). ** LEVEL is display option. If the display is set LEVEL then the value displayed will be: PROBE LENGTH (entered in QUICK SETUP) DISTANCE (see pages 7 and 8) * 4 20 ma output displayed as bar graph and in percentage [%] Measurement name (in this example, DISTANCE) Device tag name Measurement reading and unit Device status (markers) Marker 1, 2 and 3 (Error) Hardware problem; the Signal Converter hardware is defective. Contact Danfoss. Marker 4 and 5 (Notification) Depending on the level, the marker is ON or OFF. Used for Danfoss service information only. Keypad butns Flashing star indicating unit in operation. Change between: Distance* Level** Output (%)*** Output (ma)**** *** OUTPUT (%) is display option. Will represent the level of refrigerant,in percent, scaled (entered in QUICK SETUP) according : SCALE 4 ma (0%), SCALE 20 ma (100%) (see pages 7 and 8). **** OUTPUT I (ma) is display option. Will represent the level of refrigerant, in 4 20 milliampere, scaled (entered in QUICK SETUP) according : SCALE 4 ma (4 ma), SCALE 20 ma (20 ma) (see pages 7 and 8). DKRCI.PD.SC0.F H5687 5

6 Data sheet Liquid Level Sensor, type /4100U Measuring principle (Cable and Coaxial) 1. The electromagnetic (EM) pulse is transmitted by the signal converter 2. The pulse goes down the probe at the speed of light in air, V1 3. The pulse is reflected 4. The pulse goes up the probe at speed, V1 5. The converter receives the pulse and records the signal 6. The EM pulse moves at speed, V1 7. Transmitted EM pulse 8. Half of this time is equivalent the distance from the reference point of the device (the flange facing) the surface of the product 9. Received EM pulse The /4100U electronic converter emits lowintensity, high frequency electromagnetic pulses with a width of approximately 1 nanosecond, which travel at the speed of light along the probe (wire or coaxial cable) down the liquid surface. The pulses are reflected by the liquid surface, guided back along the probe, and received and analysed by the /4100U electronic converter and then converted in a liquid level reading. This method is called time domain reflecmetry (TDR) or guided microwave. The dielectric constant, εr, of the liquid is a key parameter and has a direct impact on the degree of reflection of the high frequency electromagnetic pulses. Liquids with high εr values, such as ammonia, produce strong reflections, while liquids with low εr values, such as CO2, produce weak reflections. As long as the εr value of the liquid refrigerant is higher than 1.2, /4100U can detect the liquid level and level measurement accuracy is not affected. If the temperature condition in the standpipe / vessel is known, a constant (dielectric constant of the refrigerant gas) can be entered (parameter GAS EPS.R), in order obtain improved Top and values. Refer pages 7 8 for Measuring range of AKS 4100/4100U - CABLE version and COAXIAL version. For details of gas constant values for different temperatures and refrigerants plus the procedure for entering these via the HMI, refer pages Main technical data (see a complete list of all technical data on page 11) 1 ) Coaxial 280mm and U Coaxial 11 in are only released for R717/NH 3 Supply Voltage V DC. Min/Max. Value for an output of 22 ma at the terminal. Ambient temperature supply voltage limitations: C / F : V DC C / F : V DC Load RL [Ω] ((Uext -14 V) / 20 ma). Default (Error output set 3.6 ma) RL [Ω] ((Uext -14 V) / 22 ma). (Error output set 22 ma) Cable gland PG 13, M ; (cable diameter: 6 8 mm / in. U ½ in. NPT temperature C / F Ambient temperature C / F For HMI : C / F Process pressure barg / psig Terminals (spring loaded) mm² (~20-15 AWG) Enclosure: IP 66/67 (~NEMA type 4X) Mechanical connection Cable version / Coaxial version: : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT s 1 ) The listed refrigerants are qualified and approved by Danfoss R717 / NH C / F R744 / CO C / F HCFC: R C / F HFC: R404A C / F R410A C / F R134A C / F The listed refrigerants may be used in the complete temperature range of /4100U, however, the accuracy may be affected if the above listed temperature range is exceeded. Other refrigerants within the groups of HCFC and HFC can be detected and measured if the following conditions are fulfilled: Reference conditions Dielectric constant Cable version can be used in R717 / NH 3, HCFC and HFC (εr, liquid > 5.6 ). The coaxial version is mandary for use in: - R744 / CO 2 (εr, liquid > 1.3). - Marine applications. The coaxial version can also be used in the refrigerants: R717 / NH 3, HCFC and HFC. DKRCI.PD.SC0.F H5687 6

7 Data sheet Liquid Level Sensor, type /4100U Measuring range of /4100U - CABLE version deadzone values based on the facry setting of dielectric constant length range dead zone Ammonia, HFC, HCFC [mm] [in.] [mm] [in.] Improved dead zone values after the adjustment of dielectric constant length range dead zone Ammonia, HFC, HCFC [mm] [in.] [mm] [in.] Top dead zones 120 mm / 4.7 in. Measuring range Standpipe diameter: 2 4 in. Reference point length* 20 ma (100 %)* Surface level Distance 4 ma (0 %)* Inner length of the standpipe dead zone (see tables) Counterweight: 33 mm / 1.3 in. Min: 20 mm / 0.8 in. * Values be entered in HMI Quick Setup menu and recorded on the setting label. Stick the setting label on the Signal Converter either inside or outside. Danfoss M84H0017_1 Steel wire insertion length: 12 mm / 0.5 in. DKRCI.PD.SC0.F H5687 7

8 Data sheet Liquid Level Sensor, type /4100U Measuring range of /4100U - COAXIAL D14 version Please note: It is mandary input dielectric constant for CO2 applications. Dielectric Constant εr always set during Quick Setup CO2 Facry setting Ammonia [mm] [in.] [mm] [in.] [mm] [in.] [mm] [in.] Improved dead zone values after the adjustment of dielectric constant Ammonia Facry setting HCFC,HFC [mm] [in.] [mm] [in.] [mm] [in.] [mm] [in.] Improved dead zone values after the adjustment of dielectric constant HCFC,HFC [mm] [in.] [mm] [in.] U Dielectric Constant εr always set during Quick Setup CO2 Facry setting Ammonia [in.] [in.] [mm] [in.] [in.] [mm] Improved dead zone values after the adjustment of dielectric constant [in.] [in.] [mm] 19.2 Ammonia Facry setting HCFC,HFC [in.] [in.] [mm] Improved dead zone values after the adjustment of dielectric constant [in.] [in.] [mm] 19.2 HCFC,HFC Top dead zone 120 mm / 4.7 in. Measuring range dead zone (see tables) Danfoss M84H0026_1 length* 20 ma (100 %)* Min: 30 mm / 1.2 in. Ø2 mm / 0.08 in. stainless wire Reference point Surface level Distance 4 ma (0 %)* Inner length of the stand pipe * Values be entered in HMI Quick Setup menu and recorded on the setting label. Stick the setting label on the Signal Converter either inside or outside. Measuring range of /4100U - COAXIAL D22 version Facry setting [mm] [in.] [mm] [in.] Ammonia Improved dead zone values after the adjustment of dielectric constant [mm] [in.] [mm] [in.] Ammonia U Facry setting [in.] [in.] [mm] Ammonia Improved dead zone values after the adjustment of dielectric constant [in.] [in.] [mm] Ammonia * Values be entered in HMI Quick Setup menu and recorded on the setting label. Stick the setting label on the Signal Converter either inside or outside. Top dead zone 60 mm / 2.4 in. Measuring range dead zone (see tables) length* Reference point 20 ma (100 %)* Surface level Distance Min: 30 mm / 1.2 in. 4 ma (0 %)* Inner length of the stand pipe DKRCI.PD.SC0.F H5687 8

9 Data sheet Liquid Level Sensor, type /4100U Ordering /4100U Cable version - /4100U * When ordering without HMI please observe: Each / must always be programmed via the HMI display unit. Description with 5 m / 197 in., Ø2 mm / Ø0.08 in. stainless cable and counterweight U with 5 m / 197 in., Ø2 mm / Ø0.08 in. stainless cable and counterweight Code number with HMI English (default) German French Spanish Code number with HMI English (default) Japanese Chinese Russian Code number without HMI 084H H H H H H4520 The HMI display unit can be ordered separately: 084H4540 / 084H4590 /4100U HMI display unit with rear cover and mounting bracket. The mounting bracket is very useful when the AKS 4100/4100U have be programmed. The same /4100U HMI display unit can be used programme more AKS 4100/4100U and both Cable and Coaxial versions. 084H4548 / 084H4598 /4100U HMI display unit (usually spare part). Coaxial version - /4100U (available in predefined lengths, with or without HMI) D14 D22 Description length Code number mm in. with HMI English (default) German French Spanish Code number with HMI English (default) Japanese Chinese Russian Code number Without HMI* - Coaxial D H H H Coaxial D H H H Coaxial D H H H Coaxial D H H H Coaxial D H H H Coaxial D H H H Coaxial D H H H Coaxial D22 1 ) H H H4518 U - Coaxial D H H H4524 U - Coaxial D H H H4525 U - Coaxial D H H H4526 U - Coaxial D H H H4527 U - Coaxial D H H H4528 U - Coaxial D H H H4529 U - Coaxial D22 1 ) H H H ) Coaxial 280mm and U Coaxial 11 in. are only released for R717/NH 3 Accessories Description /4100U HMI Service/Display unit with rear cover and mounting bracket Code number with HMI English (default) German French Spanish 084H4540 Code number with HMI English (default) Japanese Chinese Russian 084H4590 /4100U HMI Display 084H H4598 /4100U Signal Converter + Metaglass with HMI, excluding cable gland /4100U converter connecting cable (5 pcs.) 084H H H4556 DKRCI.PD.SC0.F H5687 9

10 Data sheet Liquid Level Sensor, type /4100U Ordering /4100U Continued Service kits Description Content Code number Cable - 5 m / 197 in., Ø2 mm / Ø0.08 in. Cable and counterweight for /4100U - CABLE version Crimp Counterweight 084H4542 End connecr incl screws for /4100U - COAXIAL D14 version End connecr (incl. 3 mm / 0.12 in. set screws) 084H4549 Process connection, counterweight and 5 m / 197 in., Ø2 mm / Ø0.08 in. cable for - CABLE and COAXIAL D14 version Process connection, counterweight and 5 m / 197 in., Ø2 mm / Ø0.08 in. cable for U - CABLE and COAXIAL D14 version 1 in. process connection Counterweight 3 4 in. NPT process connection Counterweight 084H H4546 Other spare parts Description /4100U Coaxial tube. Tube length : 680 mm / 26.8 in. /4100U blank p cover for signal converter /4100U Aluminium gaskets (10 pcs.) for 1in. process connection 1. in. welding connection Process connection - Coaxial D22 - G1 in mm Process connection U - Coaxial D22 - ¾ in. NPT 11 in. Code number 084H H H F H H4552 Dimensions and weights CABLE version Ø104 mm / Ø4.1 in. Ø2 mm / Ø0.08 in. 33 mm / 1.3 in. Ø22 mm / Ø0.9 in. Ø92 mm / Ø3.6 in mm / 7 in mm / 1.4 in. length Weight: approx. 2.3 kg / 5.1 lbs COAXIAL D14 version Ø104 mm / Ø4.1 in. Ø14 mm / Ø0.6 in. Ø21 mm / Ø0.8 in mm / 7 in mm / 1.4 in. length Weight: approx. 3.8 kg / 8.4 lbs DKRCI.PD.SC0.F H

11 Data sheet Liquid Level Sensor, type /4100U Dimensions and weights (continued) COAXIAL D22 version Ø 104 mm / Ø 4.1 in mm / 0.8 in mm / 7 in mm / 1.4 in. length Technical data Measuring system Measuring principle 2-wire loop-powered level transmitter; Time Domain Reflecmetry (TDR ) Application range Level measurement of liquid refrigerants. Approved refrigerants: Weight: 2.4 kg / 5.3 lbs Primary measured value Secondary measured value Halogen Free / Environmently friendly: R717 / NH3, R744 / CO2 HCFC and non flammable HFC. Time between the emitted and received signal Distance or level Design Options Insertions (probe) length types Cable Mechanical process connection with 5 m / 197 in., Ø2 mm / 0.08 in. stainless cable: Mechanical thread on the mechanical process connection : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT Coaxial D14 Mechanical process connection with 5 m / 197 in., Ø2 mm / 0.08 in. stainless cable and 14 mm / 0.55 in. outer stainless tube: Mechanical thread on the mechanical process connection : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT Stainless steel tubes supporting the available probe length Coaxial D22 Mechanical process connection with in 22 mm / 0.87 in. outer stainless tube. 8 mm / 0.3 in. inner rod. Mechanical thread on the mechanical process connection : G1 in. pipe thread. Aluminium gasket included U: ¾ in. NPT LCD display Coaxial D14 : 500, 800, 1000, 1200, 1500, 1700 and 2200 mm U: 19.2, 30, 45, 55, 65, 85 in. Coaxial D22 : 280 mm U: 11.0 in. Single cable Ø2 mm / 0.08 in.: mm / in. zone This depends on the type of probe. (see pages 7 and 8) Display and User interface Display Interface languages Integrated LCD display pixels in 8-step greyscale with 4-butn keypad English (default), German, French, Spanish, Japanese, Chinese, Russian Operating conditions : Ambient temperature C / F For HMI : C / F Srage temperature C / F Process connection temperature Standard C / F ure: Operating pressure Standard: barg / psig DKRCI.PD.SC0.F H

12 Data sheet Liquid Level Sensor, type /4100U Technical data (continued) Other conditions: Liquid dielectric constant (εr) Vibration resistance Protection category Cable version be used in R717 / NH3, HCFC and HFC εr, liquid > 5.6 Coaxial version is mandary in R744 / CO2 εr, liquid > 1.3 EN (1...9 Hz: 3 mm / Hz:1g; 10g shock half-wave sinusoidal: 11 ms) IP 66/67 equivalent NEMA type 4X (housing) and type 6P (probe) Installation conditions Dimensions and weights See pages 10 and 11 Material Housing Aluminium Coaxial D14 and D22 version Standard: Stainless steel ( / 316L) Single cable Standard: Stainless steel ( / 316) Process fitting Standard: Stainless steel ( / 316L) Gaskets EPDM ( C / F) Cable gland Plastic (black) Process connections Thread: Single cable Ø2 mm / 0.08 Coaxial D14 and D22 version Electrical connections Power supply Current output load Cable gland Cable entry capacity (terminal) : G1 inch pipe thread. Aluminium gasket included U: ¾ in. NPT : G1 inch pipe thread. Aluminium gasket included U: ¾ in. NPT Terminals output: V DC. Min./Max. Value for an output of 22 ma at the terminal. Ambient temperature limitations: C / F : V DC C / F : V DC RL [Ω] ((Uext -14 V)/20 ma). Default (Error output set 3.6 ma) RL [Ω] ((Uext -14 V)/22 ma). (Error output set 22 ma) : PG 13, M ; (cable diameter: 6 8 mm / in.) U: ½ in. NPT mm 2 (~20-15 AWG) Input and output Current output: Output signal 4 20 ma or ma acc. NAMUR NE 43 Resolution drift Error signal Approvals and certification ±3 μa Typically 75 ppm/k High: 22 ma; Low: 3.6 ma acc. NAMUR NE 43; Hold (frozen value - not available with NAMURNE 43 compliant output. This device fufills the statury requirements of the EMC directives. The manufacturer certifies successful testing of the product by applying the CE mark. Valid for - Not valid for U: Pattern Approval Certificate of Measuring Instruments for the Russian Federation In compliance with EMC regulations in the Russian Federation Other standards and approvals: EMC LVD NAMUR EMC Directives 2004 / 108 / EC and 93 / 68 / EEC in conjunction with EN (2006) and EN (2006). The device conforms these standards if : - the device has a coaxial probe or - the device has a single probe that is installed in a metallic tank. Low-Voltage Directives 2006 / 95 / EC and 93 / 68 / EEC in conjunction with EN (2001) NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Laborary Control Equipment NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters DKRCI.PD.SC0.F H

13 Data sheet Liquid Level Sensor, type /4100U Minimum power supply voltage Technical data (continued) Current output load R L [Ω] Use this graph find the minimum power supply voltage for a given current output load: Power supply U [VDC] Minimum power supply voltage for an output of 22mA at the terminal Note: The signal converter can be programmed with or without mechanical process connecr assembled. Quick Setup (all values below are only examples) Connect the device the power supply (see the section "Electrical installation/ connection". 3 times. SCALE 20 ma mm NO STORE NO or select either STORE NO or STORE YES. QUICK SETUP? YES change of SCALE 4 ma. change the cursor position. decrease the value or Default screen appears: PROBE TYPE SINGLE CABLE or select between SINGLE, COAXIAL D14 and COAXIAL D22. Choose SINGLE and press PROBE LENGTH mm change of SCALE 20 ma. change the cursor position. decrease the value or DISTANCE 5000 mm Quick Setup completed You have the possibility of checking your settings by pressing twice. QUICK SETUP COMPLETED IN 8 change the PROBE LENGTH. change the position of the cursor. decrease the value or Wait for QUICK SETUP complete 8-second timeout AKS QUICK QUICKSTART SETUP? YES NO SINGLE CABLE (0%) 4 ma (100%) 20 ma default screen mm 4877 mm 120 mm return SCALE 4 ma mm DKRCI.PD.SC0.F H

14 Data sheet Liquid Level Sensor, type /4100U Note: The signal converter can be programmed with or without mechanical process connecr assembled. Quick Setup (all values below are only examples) When CO2 is used: Connect the device the power supply (see the section "Electrical installation/ connection"). 3 times. change the PROBE LENGTH. change the position of the cursor. decrease the value or QUICK SETUP? YES NO PROBE TYPE SINGLE CABLE PROBE LENGTH mm QUICK SETUP COMPLETED IN 8 Wait for QUICK SETUP complete. Count down from 8 sec. AKS QUICK QUICKSTART SETUP? YES mm LIQUID CO2? YES NO (YES) confirm GAS EPS R? change of SCALE 4 ma. change the cursor position. decrease the value or SCALE 20 ma mm or select between STORE NO or STORE YES. Default screen appears: DISTANCE 5000 mm Quick Setup completed change GAS EPS.R. (Select the correct value from the tables on page 8) change cursorposition. decrease the value or STORE NO SCALE 4 ma or select between SINGLE, COAXIAL D14 and COAXIAL D22. Choose COAXIAL D14 and press NO change of SCALE 20 ma. change the cursor position. decrease the value or You have the possibility of checking your settings by pressing twice. COAXIAL D mm (0 %) 4 ma 1900 mm (100 %) 20 ma 70 mm default screen. return DKRCI.PD.SC0.F H

15 Data sheet Liquid Level Sensor, type /4100U For all other refrigerants (please note that Coaxial D22 version can only be used in R717/NH3): Connect the device the power supply (see the section "Electrical installation/ connection"). 3 times. QUICK SETUP COMPLETED IN 8 Wait for QUICK SETUP complete. Count down from 8 sec. AKS QUICK START SETUP? SCALE 4 ma mm NO YES PROBE TYPE SINGLE CABLE or select between SINGLE, COAXIAL D14 and COAXIAL D22. Choose COAXIAL D14 and press change of SCALE 4 ma. change the cursor position. decrease the value or SCALE 20 ma mm LIQUID CO2? YES QUICK SETUP? YES change the PROBE LENGTH. change the position of the cursor. decrease the value or NO (NO) confirm PROBE LENGTH mm change of SCALE 20 ma. change the cursor position. decrease the value or NO STORE NO or select between STORE NO or STORE YES. Default screen appears: DISTANCE 5000 mm Quick Setup completed DKRCI.PD.SC0.F H

16 Data sheet Liquid Level Sensor, type /4100U CABLE and COAXIAL version Forcing ma output (all values below are only examples) Default screen 4 times return default screen TESTS DISTANCE 5000 mm Default screen appears: AKS START? QUICK SETUP YES DISTANCE 5000 mm SET OUTPUT Force ma completed and disabled NO SUPERVISOR SET OUTPUT 3.5 ma decrease the value or SET OUTPUT 8 ma Enter password: INFORMATION Optional Procedure If the temperature condition in the stand pipe is known, a constant (dielectric constant of the refrigerant gas) can be entered (parameter GAS EPS.R), in order obtain lower Top and values (see pages 7 and 8). Entering refrigerant dielectric gas constant (all values below are only examples) Default screen 5000 mm AKS QUICK START SETUP? GAS EPS. R APLICATION DISTANCE YES 4 times TRACING VEL. 3 times STORE NO NO SUPERVISOR 2 times GAS EPS. R or select between STORE NO or STORE YES. Select STORE YES by pressing Default screen appears: Enter password: INFORMATION change GAS EPS.R. (Select the correct value from the tables on page 16) change cursorposition. decrease the value or DISTANCE 5000 mm Entering the dielectric constant of refrigerant gas completed GAS EPS. R DKRCI.PD.SC0.F H

17 Data sheet Liquid Level Sensor, type /4100U Saturated vapour dielectric constant (default value: 1.066) R717 (NH 3 ) range: C / F [ C] R22 range: C / F R410A range: C / F [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R744 (CO 2 ) range: C / F [ C] R134a range: C / F R404A range: C / F [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R R507 range: C / F [ C] [ F] Dielectric constant of refrigerant gas Parameter GAS EPS.R DKRCI.PD.SC0.F H

18 Data sheet Liquid Level Sensor, type /4100U How change the language setting (Default: English) Default screen DISTANCE 5000 mm QUICK SETUP START SUPERVISOR Go SUPERVISOR menu (see page 16). Go parameter Reset Facry. Select RESET FACTORY YES Enter password: LANGUAGE ENGLISH INFORMATION 6 times DISPLAY LANGUAGE Reset facry setting or see the language possibilities DISTANCE LANGUAGE 3 times STORE NO or select between STORE NO or STORE YES. Select STORE YES by pressing Default screen appears: 5000 mm Language setup completed 3 times return default screen. Facry reset completed. DKRCI.PD.SC0.F H

19 Data sheet Liquid Level Sensor, type /4100U DKRCI.PD.SC0.F H

20 DKRCI.PD.SC0.F H

Liquid Level Sensor Type AKS 4100U

Liquid Level Sensor Type AKS 4100U Data sheet Liquid Level Sensor Type U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range of refrigeration applications. The

More information

Liquid Level Sensor AKS 4100U

Liquid Level Sensor AKS 4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range

More information

Liquid Level Sensor AKS 4100/4100U

Liquid Level Sensor AKS 4100/4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sens /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sens is designed specifically measure liquid levels in

More information

Liquid Level Sensor AKS 4100U

Liquid Level Sensor AKS 4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U www.danfoss.us Liquid Level Sensor, U Contents Page Introduction...3 Features...3 Product concept...3 Cable Version...................................................................................3

More information

Type AKS 4100/4100U Coaxial D14 version

Type AKS 4100/4100U Coaxial D14 version Instruction Type /4100U Coaxial D14 version Available lengths:, 500 mm, 800 mm, 1000 mm, 1200 mm, 1500 mm, 1700 mm, 2200 mm M84H0030_1 U, 19.2 in. U, 30 in. U, 45 in. U, 55 in. U, 65 in. U, 85 in. Push

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

2291 Guided Wave Radar Level Transmitter

2291 Guided Wave Radar Level Transmitter 2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

OPTIFLEX 2200 C/F Technical Datasheet

OPTIFLEX 2200 C/F Technical Datasheet OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions

More information

OPTIFLEX 1100 C Handbook

OPTIFLEX 1100 C Handbook OPTIFLEX 1100 C Handbook Guided Radar (TDR) Level Meter Continuous level measurement of liquids and solids KROHNE : IMPRINT ::::::::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited

More information

Guided Wave Radar Level Meter

Guided Wave Radar Level Meter Guided Wave Radar Level Meter Guided Wave Radar Level Meter Instruction 1. Product Description 1.1 principle of measurement Guided Wave Radar is the measuring instruments that based on the time travel

More information

Capacitance Level Measurement Electronic insert FEC 12

Capacitance Level Measurement Electronic insert FEC 12 Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation

More information

Guided Radar (TDR) Level Transmitter for storage and process applications

Guided Radar (TDR) Level Transmitter for storage and process applications OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter 3 YEAR SENSOR WARRANTY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. General MJK Oxix s are designed

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter Data Sheet 3 YE A SEN R WAR SOR RAN TY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL:

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

Signet 2250 Hydrostatic Level Sensor

Signet 2250 Hydrostatic Level Sensor Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi

More information

Operating Instructions 09/2013

Operating Instructions 09/2013 Guided Wave Radar SITRANS LG250 4 20 ma/hart - two-wire Operating Instructions 09/2013 2 SITRANS LG250 - Operating Instructions PBD-51041047 Contents 1 About this document 1.1 Function... 5 1.2 Target

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and

More information

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS. GENERAL. A.) Overview. SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS. 1.) The luminaire shall be a color mixing luminaire employing twenty-four (24) red, green, blue, and white LED engines.

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS. GENERAL. A.) Overview. SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS. 1.) The luminaire shall be an LED strobe luminaire employing one-thousand, three-hundred and fifty (1350) white LED engines.

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

TUC: Universal thermostat

TUC: Universal thermostat Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS. GENERAL. A.) Overview. SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS. The luminaire shall be an LED strobe luminaire employing five hundred and twenty eight (528) red, green, blue and white

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

FLOMAT Electromagnetic Insertion Flowmeter

FLOMAT Electromagnetic Insertion Flowmeter LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an

More information

FIELD MOUNTED RATE TOTALISER MODEL 202D

FIELD MOUNTED RATE TOTALISER MODEL 202D FIELD MOUNTED RATE TOTALISER MODEL 202D 16 June 2003 Introduction 1 1. INTRODUCTION The Model 202Di Rate Totaliser is a microprocessor based instrument which accepts a frequency or pulse input from

More information

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Limit Detection nivotester FTC 420/421/422 Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Filters for Power Lines (Low Leakage Current)

Filters for Power Lines (Low Leakage Current) Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Pressure transmitter COMPACT IO-Link,

Pressure transmitter COMPACT IO-Link, Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic

More information

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil Integrated Display Type Flow rate range 0 2 5 Symbol 0 02 03 0 Specifications ow Order PFA7 0 0 27 0l/min 5 l/min 0 00l/min 20 200l/min 0l/min Port size /8 / 3/8 /2 Model Measured fluid Detection type

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

GRUNDFOS alldos product information. The solution for complex dosing tasks

GRUNDFOS alldos product information. The solution for complex dosing tasks GRUNDFOS alldos product information The solution for complex dosing tasks Measurements Measurements a h d Electric actuator b Pneumatic actuator g e Ø 9mm k f i m 1 m 2 k j c n l 1 l 2 DMH model Measurements

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

Roof-mounted Blue e+ cooling unit Integration solution VX25

Roof-mounted Blue e+ cooling unit Integration solution VX25 Roof-mounted Blue e+ cooling unit Integration solution VX25 Ease of use Intuitive operation via touch display Integration solution VX25 and Blue e+ Cooling unit with 1.3 kw and Blue e+ technology with

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches

More information

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series. Sultan Sonar Manual Rev 1.0 A Higher Level of Performance Manual Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com Table of Contents Contents Overview 3 Principle

More information

Dynatel Advanced Cable Locator 2250

Dynatel Advanced Cable Locator 2250 3 Dynatel Advanced Cable Locator 2250 Quickly and Accurately Identify Underground Assets Pinpoint exact cable path and depth quickly and easily with this lightweight, easy-to-handle unit The 3M Dynatel

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red Datasheet Large Multicolor that Alternates Between Active Inputs Bright, uniform indicator light Alternates between colors when multiple inputs are active Models are available with up to five colors in

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Technical Information RIA46 Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Application Process recording and supervision Process control Signal

More information

Operating Instructions

Operating Instructions Operating Instructions LEVEL TRANSMITTER 8188 4 20 ma/hart two-wire Rod and cable probe 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbols used... 4 2 For your

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C Hygrotest 600 Instruction manual en WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C Contents Introduction...2 Handling instructions...3 Dimensions of measuring instrument...3

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications ABB MEASUREMENT & ANALYTICS DATA SHEET AZ00 series Zirconia oxygen analyzer for small boiler applications AZ 00 SE RIE S Z I RCON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview. Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

Operating Instructions 09/2013

Operating Instructions 09/2013 Guided Wave Radar SITRANS LG260 4 20 ma/hart two-wire Operating Instructions 09/2013 2 SITRANS LG260 - Operating Instructions PBD-51041057 Contents 1 About this document 1.1 Function... 5 1.2 Target group...

More information

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids Flowmeters Instrumentation for fluids Series FLOMT FLOMT Electromagnetic Insertion Flowmeter: Introduction For use in large diameter pipes or open channels as an economical solution for liquid metering.

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

Smart-Encoder : Optical Incremental

Smart-Encoder : Optical Incremental 1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow controls VFC Linear flow controls with actuator IFC Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Technical Information RIA45 Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Application Plant and apparatus engineering and construction Control

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information