I Ex-protected connectors exlink I

Size: px
Start display at page:

Download "I Ex-protected connectors exlink I"

Transcription

1 Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity IECEx BKI X Marking accd. to IECEx Ex ed IIC T6 / Ex ia/ib IIC T6 Ex td A21 IP66 T52 C Permissible ambient temperature 20 C up to + 40 C Store temperature in original wrapping 55 C up to + 80 C Rated voltage AC up to 250 V, 50/60 Hz / DC up to 60 V Rated current with terminal block AC - max. 9.3 A DC - max. 2.5 A without terminal block AC - max A DC - max. 2.5 A Frequency range MHz, fast Ethernet compatible Transmission performance acc. to TIA/EIA-568-B.2 Category 5e up to 100 Mbaud External back-up fuse max. without thermal protection 10 A External back-up fuse max. with thermal protection 20 A gl Breaking capacity acc. to EN : AC V / 10.0 A DC - 60 V/ 2.5 A Rated making/rated breaking capacity AC-3 Ue 250 V / Ie 1.0 A acc. to EN DC-3 Ue 60 V / Ie 0.5 A Insulation class acc. EN II / I Wire cross section Y-junction box multi wire 0.34 mm mm 2 extra fine wire 0.34 mm mm 2 Cable entry Y-adaptor Ø mm / Ø mm Degree of protection EN IP66/IP68 with closed and locked protective caps or duly plugged and locked components Enclosure material Polyamide (PA) 6.40 COOPER CROUSE-HINDS GMBH

2 Y-junction-box 2 x cable glands I Ex-protected connectors exlink I 3 x Inlet or receptacle Pos. A 1 2 Inlet or receptacle Pos. B Pos. C Ordering key Y-junction-box 3 7. Diameter of connection cable GHG 57X X6XX RXX0X 1 = mm 2 = mm 4 4. Coding 5. Material 6. Locking device 5 1 = Y-junction box inlet 2 = Y-junction box receptacle 01 = 1 h 02 = 2 h 04 = 4 h 05 = 5 h 06 = 6 h 08 = 8 h 10 = 10 h 12 = 12 h plastic stainless steel 3 = exlink in nickel-plated brass Enclosure material made of plastic (PA) 9 = with 6 Ordering key GHG 57X XXXXX RXXXX Coding 4. Material 5. Locking device 8 = Inlet 9 = Inlet Enclosure material made of plastic (PA) (A) (B) (C) (A) (B) (C) Pos. A - B - C: 01 = 1 h Pos. A - B - C: 02 = 2 h Pos. A - B - C: 04 = 4 h Pos. A - B - C: 05 = 5 h Pos. A - B - C: 06 = 6 h Pos. A - B - C: 08 = 8 h Pos. A - B - C: 10 = 10 h Pos. A - B - C: 12 = 12 h plastic stainless steel 3 = exlink in nickel-plated 1 = A / / 2 = / B / 3 = / / C 4 = A / B / C 5 = A / B / 6 = A / / C 7 = / B / C 9 10 All s with protective caps 11 COOPER CROUSE-HINDS GMBH

3 Y-Junction box GHG 57X X6XX RXX0X 7. Diameter of connection cable 1 = 4.0 7,5 mm 2 = mm 4. Coding 5. Material 6. Locking device 1 = Y-Junction box inlet 2 = Y-Junction box receptacle All s with protective caps 01 = 1 h 02 = 2 h 04 = 4 h 05 = 5 h 06 = 6 h 08 = 8 h 10 = 10 h 12 = 12 h plastic stainless steel 3 = exlink in nickelplated brass Enclosure material made of plastic (PA) 9 = with Ordering details Y-Junction-box Voltage No. of Coding Connection Diameter of connection cable poles mm mm Y-Junction-box with exlink inlet made of plastic Ethernet/Bus 4-pol + PA 1 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 4 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 4 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V DC 4-pol + PA 5 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V DC 4-pol + PA 5 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 6 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 6 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V DC 4-pol 8 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V DC 4-pol 8 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V AC 4-pol + PE 10 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 4-pol + PE 10 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 12 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 12 h Cage clamp 2.5 mm 2 GHG R0001 GHG R0002 Y-Junction-box with exlink inlet made of stainless steel Ethernet/Bus 4-pol + PA 1 h Cage clamp 1.5 mm 2 GHG R1001 GHG R V AC 2-pol + PE 4 h Cage clamp 1.5 mm 2 GHG R1001 GHG R V AC 2-pol + PE 4 h Cage clamp 2.5 mm 2 GHG R1001 GHG R V DC 4-pol + PA 5 h Cage clamp 1.5 mm 2 GHG R1001 GHG R V DC 4-pol + PA 5 h Cage clamp 2.5 mm 2 GHG R1001 GHG R V AC 2-pol + PE 6 h Cage clamp 1.5 mm 2 GHG R1001 GHG R1002 Y-Junction-box receptacle made of plastic Ethernet/Bus 4-pol + PA 1 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 4 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 4 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V DC 4-pol + PA 5 h Cage clamp 1.5 mm 2 GHG R0001 GHG R V DC 4-pol + PA 5 h Cage clamp 2.5 mm 2 GHG R0001 GHG R V AC 2-pol + PE 6 h Cage clamp 1.5 mm 2 GHG R0001 GHG R COOPER CROUSE-HINDS GMBH

4 1 2 GHG 57X XXXXX RXXXX 3 8 = with Inlet (A) (B) (C) 9 = with (A) Inlet (B) (C) 3. Coding Pos. A - B - C: 01 = 1 h Pos. A - B - C: 02 = 2 h Pos. A - B - C: 04 = 4 h Pos. A - B - C: 05 = 5 h Pos. A - B - C: 06 = 6 h Pos. A - B - C: 08 = 8 h Pos. A - B - C: 10 = 10 h Pos. A - B - C: 12 = 12 h 4. Material plastic stainless steel 3 = exlink in nickel-plated 5. Locking device 1 = A / / 2 = / B / 3 = / / C 4 = A / B / C 5 = A / B / 6 = A / / C 7 = / B / C 4 5 All s with protective caps 6 Ordering details Voltage No. of poles Coding Pos. A/Pos. B Pos. C Pos. A/Pos. B Pos. C Inlet/receptacle-receptacle /inlet-receptacle Y-adaptor with exlink 4-pole/4-pole + PE components made of plastic Ethernet/Bus 4-pol. + PA 1 h GHG R0100 GHG R V AC 2-pol. + PE 4 h GHG R0400 GHG R V DC 4-pol. + PA 5 h GHG R0500 GHG R V AC 2-pol. + PE 6 h GHG R0600 GHG R V DC 4-pol. 8 h GHG R0800 GHG R V AC 4-pol. + PE 10 h GHG R1000 GHG R V AC 2-pol. + PE 12 h GHG R1200 GHG R1200 Y-adaptor with exlink 4-pole/4-pole + PE components made of stainless steel Ethernet/Bus 4-pol. + PA 1 h GHG R0110 GHG R V AC 2-pol. + PE 4 h GHG R0410 GHG R V DC 4-pol. + PA 5 h GHG R0510 GHG R V AC 2-pol. + PE 6 h GHG R0610 GHG R V DC 4-pol. 8 h GHG R0810 GHG R V AC 4-pol. + PE 10 h GHG R1110 GHG R V AC 2-pol. + PE 12 h GHG R1210 GHG R1210 Y-Adapter with exlink 4-pole/4-pole + PE components made of nickel-plated brass Ethernet/Bus 4-pol. + PA 1 h GHG R0130 GHG R V AC 2-pol. + PE 4 h GHG R0430 GHG R V DC 4-pol. + PA 5 h GHG R0530 GHG R V AC 2-pol. + PE 6 h GHG R0630 GHG R V DC 4-pol. 8 h GHG R0830 GHG R V AC 4-pol. + PE 10 h GHG R1130 GHG R V AC 2-pol. + PE 12 h GHG R1230 GHG R1230 COOPER CROUSE-HINDS GMBH

5 Mounting plate Accessories Type OU Version 3+PE 4 pol. 4+PE Plastic protection cap connector/receptacle 1 X X X GHG R0001 Plastic protection cap plug/inlet 1 X X X GHG R0002 Brass protection cap connector/receptacle 1 X X X GHG R0003 Brass protection cap plug/inlet 1 X X X GHG R0004 Strain relief and seal mm 1 X X X GHG R0001 Strain relief and seal mm 1 X X X GHG R0002 Mounting plate 1 X X X GHG R0001 Dimension drawings Mounting plate Y-Junction box Dimensions in mm COOPER CROUSE-HINDS GMBH

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

EX-PROTECTED PORTABLE POWER SUPPLY UNITS EX-PROTECTED PORTABLE POWER SUPPLY UNTS 125 A for Zone 1 Special requirements apply for power distributions for the use and operation of portable equipment in hazardous areas in Zones 1, 2, 21 and 22.

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

SERIES 400 SERIES 620

SERIES 400 SERIES 620 x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x

More information

Pendant Light Fittings Series 6050

Pendant Light Fittings Series 6050 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

COMBINATION UNITS MARCH 2018

COMBINATION UNITS MARCH 2018 COMBINATION UNITS MARCH 2018 2 COMBINATION UNITS STATIONARY SOCKET OUTLET COMBINATIONS Variants 5 Dimensions 6 Wall-mounted Distributor Boxes (plastic) Series 45 8 Wall-mounted Distributor Boxes (plastic)

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Read/Write Head TN-M30-H1147

Read/Write Head TN-M30-H1147 Threaded barrel, M30 x 1.5 Chrome-plated brass /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030004 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating voltage 10 30

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Read/write head TN-M18-H1147

Read/write head TN-M18-H1147 Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12360 This is to certify that the Cable Gland with type designation(s) ADE & RE; AD; FF; MM; SP; ET; LN. Manufactured by COOPER CAPRI SAS

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics Amphenol C 6- / C 6- Circular Circular Connectors Connectors Amphenol-Tuchel Electronics General information We reserve the right to change the design due to improvement in quality, development or production

More information

Safety dialogue solutions

Safety dialogue solutions Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

2L-CG-Monitoring Module

2L-CG-Monitoring Module 2-CG-Monitoring Module 2-CG 2-CG 0.06 kg of mounting (H x x B) 27.5 x x Connection terminals oop terminals 2 x 2.5 mm 2 Voltage ranges 230 V 50/60 Hz, 220 V DC +25/-20 % see ordering details Max. length

More information

Certificate No.: i IECEx SIR issue No.:1 9.!~~~t~I~t.CJ!y:... Issue No.1 ( ) Status;

Certificate No.: i IECEx SIR issue No.:1 9.!~~~t~I~t.CJ!y:... Issue No.1 ( ) Status; IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www-iecex.com Certificate No.:

More information

Pressure transmitter For applications in hazardous areas Model IS-3

Pressure transmitter For applications in hazardous areas Model IS-3 Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

Datasheet EC-750 Ex DOME Camera

Datasheet EC-750 Ex DOME Camera Product: EC-750 Ex DOME Camera Description and highlights Explosion proof color TV camera with swivelling head and zoom Chemical, shock and vibration resistant Water- and dustproof IP68 Compact and light

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine. Thermoacoustics Technical Brochure Product Line for Combustion Dynamics on Gas Turbine Modular Measuring Chains. This technical brochure provides an overview how the various system components of the Kistler

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

82540/ /2-way diaphragm valves

82540/ /2-way diaphragm valves > > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Control cabinet interface and cable entry systems

Control cabinet interface and cable entry systems Modlink MPV Control cabinet interface The Modlink MPV control cabinet interface provides the connection from the control cabinet to the fieldbus environment (outside) in a simple way. Durable connection

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

AC 2-wire Inductive Sensors

AC 2-wire Inductive Sensors Tubular, M12 1 AC-sensors are optimized for controllers with alternating current inputs. When maintaining the rated operating current, the sensors can directly control fuses and relays. Housing size M12

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

10 PDUs 19 PDUs Zero-U PDUs

10 PDUs 19 PDUs Zero-U PDUs 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Nessie Coils for VDH and VDHT valves

Nessie Coils for VDH and VDHT valves Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Interface RF Connector with Switch, built-in interlock, DC to 3GHz

Interface RF Connector with Switch, built-in interlock, DC to 3GHz Interface RF Connector with Switch, built-in interlock, DC to 3Hz MS-151NB Series Overview Designed for end user applications requiring redirection of transmission from internal built-in antenna to the

More information

1.2 EUREKA Series... from page c.14

1.2 EUREKA Series... from page c.14 .2 EUREKA Series................................................................................................. from page c.4 This latest generation of industrial plugs, connectors and socket outlets

More information

Heating films. Articelnumber build:

Heating films. Articelnumber build: Frenzelit GmbH 2018 Heating films The hicotherm 36 V heating film can be installed inconspicuously into a wall, ceiling and floor and brings a new feel-good experience to your home. Number Name Description

More information

Catalog. Industrial Plugs & Sockets The complete range

Catalog. Industrial Plugs & Sockets The complete range Catalog Industrial Plugs & Sockets The complete range Contents Type Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs Splashproof...

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main. Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main. Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

AC diagonal module Ø 200 mm

AC diagonal module Ø 200 mm max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:

More information

ATEX-manual for units

ATEX-manual for units ATEX-manual for units LMK70-ATEX (Zone 0) LMK70-ATEX (Zone 0/20) ATEX-Barrier Generic installation directive according to EN60079-14 (Gas) EN60079-17 (Maintenance Gas) Since LMK70-ATEX is intrinsically

More information

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

LIGHTING SOLUTIONS. The bright side of the ship

LIGHTING SOLUTIONS. The bright side of the ship LIGHTING SOLUTIONS The bright side of the ship Philosophy Three things you should know about us 1Established by experienced specialists in 1995, Lightpartner has developed into the leading provider of

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and

More information

KVT Split cable glands

KVT Split cable glands KVT Split cable glands Description Type Order Inserts KT Thread PU No. small large Thread length KVT is a circular split frame for quick and easy installation of cables or complete cable harnesses. Polyamide

More information

Quality products from a single source

Quality products from a single source Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

ABB IEC International Pin and Sleeve

ABB IEC International Pin and Sleeve Approved According to IEC 60 309-1, -2, -4 Range from 16 up to 125 Amp, up to 600V, IP67 (Watertight) Safety Proven performance: With more than 30 years of experience, ABB IEC Pin and Sleeve Connectors

More information

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS SERIES BNC 50, COAXIAL MINIATURE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER BNC is still one of the most popular connector series, featuring a two stud bayonet coupling mechanism, which is particularly

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35 General ordering data Order No. 1020000000 Part designation WDU 2.5 Version EAN 4008190099633 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, Product notes Note, ordering data

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

M5 plug connector, 3-pin or hard-wire encapsulated cable. With. With connection cable. M5 plug connector. Active face LED

M5 plug connector, 3-pin or hard-wire encapsulated cable. With. With connection cable. M5 plug connector. Active face LED Read head CES-A-LSP-... Optimized for aluminum profile mounting LED for the indication of the door position Read head CES-A-LSP-... M plug connector, -pin or hard-wire encapsulated cable Dimension drawing

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) RCA PLUGS & JACKS 24-100-0 Bulk 24-100-2 Pkg (2) Metal body RCA plug. Maximum cable dia. 7.5mm 24-104-0 Bulk 24-104-2 Pkg (2) Metal plug with strain relief. Maximum cable dia. 4.5mm Use 84-156-1 tool for

More information

EMC Solutions Noise filtering

EMC Solutions Noise filtering Power & Signal Quality TRABTECH EMC Solutions Noise filtering Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar 0D (Pneumatic) Electronic pressure switch -... 0 bar, -... bar, 0... 6 bar, 0... 0 bar, 0... bar Fast error detection viamulti-colour display Easy to use pressure switch with clear display and intuitive

More information