20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Size: px
Start display at page:

Download "20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)"

Transcription

1 OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for the light curtain. 0 mm beam pitch Compared to the conventional model, much smaller objects can be detected. 0 mm beam pitch Minimum sensing object: "60 mm Minimum sensing object: "0 mm 0 mm beam pitch Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) Parts shelf position D 0 mm beam pitch area sensor 0 mm beam pitch area position sensor Parts shelf D Wide variety There are eight types of sensors having a sensing height ranging from 0 mm ( beam ) to,60 mm (6 beam ). A spatter protection hood type sensor is also available that protects the sensing face against welding spatters. 0 mm beam pitch 0 mm beam pitch Smaller is the beam pitch, smaller can be the setting distance D. height,60 mm 6 beam 56 beam beam 0 beam beam beam 6 beam beam 0 mm Incorporates useful functions Self-diagnosis function Both the emitter and the receiver automatically check the internal circuit every 5 ms. Should a trouble occur in the sensor, the output is forced to the OFF state. Further, the indicators show the type of error. Test input (emission halt) function The emission can be forcibly stopped by an external input to check if the output follows it. It is convenient for an operation check before start-up. Modular construction The series has been the first to realize modular construction for 0 mm beam pitch area sensors. It allows easy change in the beam channel number. Front cover Main unit Fixing screws Sub-unit End cap Fixing screws Protection enclosure Long sensing range: 7 m Its maximum sensing area is 7 m long and,60 mm high with a 0 mm beam pitch.,60 mm 7 m External input 0V PLC, Switch, etc. 0

2 APPLICATIONS Checking leftover workpiece Detecting an object in handler OTHER SUNX PRODUCTS WARNING ORDER GUIDE Never use this product in any personnel safety application. Sensors Mating cable is not supplied with the sensor. Please order it separately. Type Appearance range Beam channel No. 6 Number of beam 6 height (mm) 0 00 height Beam pitch m 0 mm Area sensor Beam channel No. Optional mating cable 7 m 6 -H 6,60 0 With spatter protection hood 0.5 m height Beam pitch 0 mm 6-H -H -H 0-H -H 56-H Optional mating cable 6-H 6,60 Mating cables Mating cable is not supplied with the sensor. Please order it separately. Appearance Description SF-CCA SF-CC7A Length: m Weight: 600 g approx. (two cables) Length: 7 m Weight: 950 g approx. (two cables) 0.5 mm -core cabtyre cable, with connector on one end, two cables per set Cable outer diameter: "7 mm Connector outer diameter: " mm max. Cable color: Gray (for emitter) Gray with black line (for receiver) Accessory MS-SF- (Sensor mounting bracket) Four bracket set Four M6 (length 0 mm) truss head screws, four nuts and four spring washers are attached. 05

3 OTHER SUNX PRODUCTS ORDER GUIDE Individual units and associated components can be purchased separately. Designation Main unit Sub-unit End cap MP SP SF-EP MD SD SF-ED End cap Sub-unit Protection enclosure Main unit Front cover Designation Protection enclosure With spatter protection hood Applicable beam beam MC-SF- 6 beam MC-SF-6 beam MC-SF- beam MC-SF- 0 beam MC-SF-0 beam MC-SF- 56 beam MC-SF-56 6 beam MC-SF-6 MC-SF-H MC-SF-6H MC-SF-H MC-SF-H MC-SF-0H MC-SF-H MC-SF-56H MC-SF-6H Front cover FC-SF- FC-SF-6 FC-SF- FC-SF- FC-SF-0 FC-SF- FC-SF-56 FC-SF-6 Note: The model Nos. given above denote a single unit, not a pair of units. OPTIONS Designation Description Large indicator With the large indicators put on the sensors, the operation is easily observable from various directions. Forming B Line Large indicator for area sensor (Note) SF-IND Specifications Supply voltage: to V DC0 % Ripple P-P 0 % or less Current consumption: 0 ma or less Indicators: Three orange LEDs Either light up, blink, or light off as selected by the input wire Ambient temperature:0 to55 C Cable: 0. mm -core oil resistant cable, m long Cable extension: Extension up to total 00 m is possible with 0. mm, or more, cable. Material: Polycarbonate (Cover), POM (Mounting base) I/O circuit diagram SF-IND Blinking circuit kω Color code (Brown) COM. (Black) Lighting input (Blue) Blinking input to V DC 0 % Input specifications Applied voltage: V DC or less (between COM. and input) ON voltage: 9.6 V or more (between COM. and input) OFF voltage: 5 V or less (between COM. and input) Input impedance: kω approx. Sensor mounting bracket Slit mask Sensor mounting bracket Designation Slit mask 06 MS-SF-P Applicable beam Internal circuit beam Blinking Lighting It consists of one set of two brackets each for the emitter and the receiver. Note: Two SF-INDs are required if they are to be mounted on, both, the emitter and the receiver. 6 beam beam beam 0 beam beam 56 beam 6 beam OS-SF- OS-SF-6 OS-SF- OS-SF- OS-SF-0 OS-SF- OS-SF-56 OS-SF-6 Note: The model Nos. given above denote a single unit, not a pair of units. The slit mask restrains the amount of beam emitted or received and hence reduces the interference between neighboring sensors. It is also used in cases when the beam intensity is too strong penetrating through the sensing object. Replace the original front cover with the slit mask. However, the sensing range reduces when the slit mask is used. range Slit on emitter side: m Slit on receiver side:.6 m Slit on both sides:. m

4 SPECIFICATIONS Number of beam With spatter Item protection hood height range Beam pitch object Supply voltage H 6-H -H -H 0-H -H 56-H 6-H 0 mm 00 mm 60 mm 60 mm mm 90 mm mm,60 mm 7 m 0 mm "0 mm or more opaque object ("5 mm or more opaque object if the setting distance is less than 0.5 m.) to V DC0 % Ripple P-P 0 % or less OTHER SUNX PRODUCTS Current consumption : 55 ma or less : 60 ma or less : 70 ma or less : 75 ma or less : 5 ma or less : 90 ma or less : 00 ma or less : 05 ma or less Output NPN open-collector transistor Maximum sink current: 00 ma Applied voltage: 0 V DC or less (between output and 0 V) Residual voltage:.6 V or less (at 00 ma sink current) Output operation Short-circuit protection Response time Indicators Test input (emission halt) function Interference prevention function Environmental resistance Protection Ambient temperature Ambient humidity Ambient illuminance Noise immunity Voltage withstandability Insulation resistance Vibration resistance Shock resistance Emitting element Material ON when all beam are received / OFF when one or more beam are interrupted (OFF, also, when the sensor fails. Refer to Operation matrix on p.0.) Incorporated ms or less Emitting indicator: Green LED ( ( lights up under normal emission, blinks under emitting circuit failure or on cable break between the synchronization and the external input terminals when interference prevention function is used (only the emitting indicator of the Sensor B blinks), and lights off under no emission lights up when one or more beam are interrupted, and blinks when extraneous light Operation indicator: Red LED is received Stable incident beam indicator: Green LED (lights up when all beam are received stably) Unstable incident beam indicator: Yellow LED (lights up when one or more beam are received unstably) m The three color indicators blink in rotation when the receiving circuit fails, and blink simultaneously when the output circuit fails. The operation indicator and the unstable incident beam indicator blink alternately when the synchronization wire breaks or the emitting circuit fails. Incorporated Incorporated (Two units of sensors can be mounted close together.) IP65 (IEC) 0 to55 C (No dew condensation or icing allowed), Storage: 0 to60 C 5 to 5 % RH, Storage: 5 to 5 % RH Sunlight: 0,000?x at the light-receiving face, Incandescent light:,500?x at the light-receiving face Power line: 0 Vp, 0ms cycle, and 0.5!s pulse width Radiation: 00 Vp, 0ms cycle, and 0.5!s pulse width (with noise simulator),000 V AC for one min. between all supply terminals connected together and enclosure 0 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure 0 to 55 Hz frequency,.5 mm amplitude in X, Y and Z directions for two hours each 00 m/s acceleration (0 G approx.) in X, Y and Z directions for three times each Infrared LED (modulated) Protection enclosure: Aluminum, Unit case: ABS, Front cover: Acrylic, Lens: Acrylic ) ) Cable Cable extension Weight (Total of emitter and receiver) With spatter protection hood Accessory 0.5 mm -core cabtyre cable, 0.5 m long with a round connector at the end m Use together with the optional mating cable Extension up to total 0 m is possible, for both emitter and receiver, with 0.5 mm, or more, cable. 500 g approx. 0 g approx.,70 g approx.,500 g approx.,0 g approx.,70 g approx.,500 g approx.,0 g approx. 60 g approx.,00 g approx.,50 g approx.,990 g approx.,0 g approx.,900 g approx.,50 g approx.,00 g approx. MS-SF- (Sensor mounting bracket): set for emitter and receiver 07

5 OTHER SUNX PRODUCTS I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Sensor circuit Sensor circuit D Internal circuit D Connector pin No. Color code Synchronization (Note ) ZD Load (Black) Output Tr 00 ma max. Internal circuit Users circuit Users circuit Used for test input (Pink) External input (emission halt) function or interference prevention function. Synchronization (Note ) to V DC 0 % (Note ) Notes: ) Do not connect the synchronization wire to the ES terminal (external input) of NPS sensor controller. Notes: ) To supply power to the emitter and the receiver from separate power supplies, be sure to connect both 0V (blue) wires in common and adjust both the power supplies to the same voltage. Notes: ) Unused wires must be insulated to ensure that they do not come into contact with wires already in use. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor Wiring diagram Synchronization 0 V (Blue) Synchronization 0 V (Blue) V (Brown) External input (Pink) Brown Blue Pink Orange / Violet V (Brown) Output (Black) Orange / Violet Brown Black Blue Load to V DC 0 % Used for test input (emission halt) function or interference prevention function. Notes: ) Do not connect the synchronization wire to the ES terminal (external input) of NPS sensor controller. Notes: ) To supply power to the emitter and the receiver from separate power supplies, be sure to connect both 0V (blue) wires in common and adjust both the power supplies to the same voltage. Notes: ) Unused wires must be insulated to ensure that they do not come into contact with wires already in use. SENSING CHARACTERISTICS (TYPICAL) Parallel deviation (All models) Vertical direction Angular deviation (All models) angular deviation L Setting distance L (m) 6 Vertical & horizontal directions $ L Setting distance L (m) 6 Common for both angular deviations Horizontal direction # 0, ,000 (Down) Left Center Right (Up) Operating point #(mm) angular deviation Left Center Right Operating angle $( ) L $ L 0

6 PRECAUTIONS FOR PROPER USE Mounting Do not use the sensor without the front cover or the enclosure. IP protection cannot be maintained and a contact failure may occur between modular units. When mounting the sensor, the tightening torque should be Nm or less. Wiring When using one set of sensor Color code (Pink) External input wire Synchronization wire Synchronization wire (Black) Output Load V 0 V Connect both the synchronization wires. Connect both the 0 V wires in common. Although both the V wires need not be connected in common, they must be at the same voltage. To use the test input (emission halt) function, connect a switch between the external input wire and 0V. If this function is not used, insulate the external input wire. When using two sets of sensors (Using interference prevention function) of Sensor A of Sensor A of Sensor B of Sensor B Never use this product as a sensing device for personnel protection. For sensing devices to be used as safety devices for press machines or for personnel protection, use products which meet standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. If this product is used as a sensing device for personnel protection, death or serious body injury could result. For a product which meets safety standards, use the following products. Type : SF-AH series (p.0l), SF-EH series (p.6l) Type : SF-A series (p.6l), SF-N series (p.6l) Color code (Pink) External input wire Synchronization wire Synchronization wire (Black) Output Load 5 (Pink) External input wire Synchronization wire Synchronization wire (Black) Output Load V 0 V Area A Area B Sensor A Sensor B Connect together the synchronization wires of both the sensors. Connect both the 0 V wires in common. Although both the V wires need not be connected in common, they must be at the same voltage. Connect the external input wire of Sensor B to synchonization wire of Sensor A to prevent interference between Sensor A and Sensor B. 5 To use the test input (emission halt) function, connect a switch between the external input wire of Sensor A and 0 V. If this function is not used, insulate the external input wire. Object Refer to p.5l for general precautions. Test input (emission halt) function Making the external input wire (pink) Low stops the emission and turns off the emitting indicator. Because this function turns the output on and off without any object, it is useful for a start-up test. (Pink) External input High External input Low Output ON OFF T 0 ms T msignal condition Non-voltage contact or NPN open-collector transistor Normal Error or Low (0 to V): Emission halt High (.5 to 0 V, or open): Emission Note: When two sets are used with interference prevention, the external input wire that is not connected to the synchronization wire is shortcircuited to 0V (refer to Wiring ). This stops the emission of both sensors. If the output follows the change (High and Low) of the external input, the sensor is normal. If it does not, the sensor is in error condition. Tj0 ms Others Do not use during the initial transient time (.5 sec.) after the power supply is switched on. Take care that the sensor is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Install the sensor where it cannot be affected by a beam reflected from a machinery frame or a workpiece. If the reflected beam from machine or workpiece is received, beam interruption is not achieved. OTHER SUNX PRODUCTS 09

7 OTHER SUNX PRODUCTS PRECAUTIONS FOR PROPER USE : lights up : Blinks : lights off : Uncertain (operation according to situation) : Locked due to breakdown (Note) Indicators Item Beam received stably Normal (All beams) operation Beam interrupted (One or more beams are interrupted) Error conditions Emitting element failure Emitting circuit failure Receiving element failure Receiving circuit failure Output error Power wire broken Synchronization wire broken Synchronization / External input wire broken Sensor B only when the interference prevention function is used ( Insufficient beam intensity (Beam received unstably) Unit ) Emitting Stable indicator (Green LED) incident beam indicator (Green LED) Unstable incident beam Operation indicator indicator (Yellow LED) (Red LED) Outputs ON OFF OFF OFF OFF ON Refer to p.5l for general precautions. Operation matrix The condition of the sensor can be known from the operation indicators of the sensor and the output operation. Sequential Simultaneous Alternate Alternate Note: The indicators on the receiver operate as follows depending on the incident light intensity. High Incident light intensity (%) Output operation Beam received operation 5% 00% (ON) Beam interrupted operation Low 0% (OFF) Green Indicator operation Stable incident beam indicator (Green) Unstable incident beam indicator (Yellow) Lights up Lights up Yellow Operation indicator (Red) Lights up Red Changing the number of beam Slide the cover stopper Remove the four fixing in the direction of the screws on the rear arrow and pull the front face. cover upward. Pull the modules upward one by one with your hands. Arrange the new protection enclosure and front cover that matches the required sensing height. Insert the units and connect the end cap. Cover stopper d d Module d Front cover Notes: ) Be sure to turn the power supply off before linking units. If this is not done, the sensor may get damaged. Notes: ) Do not apply excess force to the units while linking. Notes: ) Be sure to put the end cap on the top. Notes: ) The fixing screws are attached to the protection enclosure. k 5 Tighten the four fixing screws and insert the front cover by pulling the cover stopper back. 0

8 DIMENSIONS (Unit: mm in) Sensor The CAD data in the dimensions can be downloaded from the SUNX website: OTHER SUNX PRODUCTS -"6.5 mounting holes height Emitting indicator (Green) A B C A B C (500) Three color indicators (Green, Yellow, Red) 0 Beam pitch , ,9 () 0.5 6,60,9,09 -H Sensor 50 -"6.5 mounting holes Indicator window Emitting indicator (Green) Three color indicators (Green, Yellow, Red) 0 A 0 height Beam pitch Indicator window 0 B 0 00 C -H 6-H -H -H 0-H -H A B C (500).5 56-H 6-H,60,,9,9,09 () 0.5

9 OTHER SUNX PRODUCTS DIMENSIONS (Unit: mm in) MS-SF-.5 The CAD data in the dimensions can be downloaded from the SUNX website: Sensor mounting bracket (Accessory) "6 Assembly dimensions Mounting drawing with. The assembly for the spatter protection hood type (-H) is similar. () "6.5 (on both sides) (.5) 7 7 t 5.5 t A height Beam pitch (D) (E) (-H) 6(-H) (-H) A D E (-H) 0(-H) (-H) 56(-H) ,005, ,09,79 6(-H),60,5,9 Material: Cold rolled carbon steel (SPCC) Material: (Uni-chrome plated) Four bracket set pcs. each of M6 (length 0 mm) truss head screws, nuts and spring washers are attached. MS-SF-P Sensor mounting bracket (Optional) () "7 "7 6.5 () " t. 9. t "6.5. Material: Cold rolled carbon steel (SPCC) Material: (Uni-chrome plated) Four bracket set Assembly dimensions Mounting drawing with. The assembly for the spatter protection hood type (-H) is similar. (55) (5) 6.5 "7 5 height 7 (-H) 6(-H) A F G A (F)(G) (-H) Beam pitch (-H) (-H) (-H) 90 60,00 0,00 56(-H),0,00 6(-H),60,0,60

10 DIMENSIONS (Unit: mm in) SF-IND The CAD data in the dimensions can be downloaded from the SUNX website: Large indicator for area sensor (Optional) Assembly dimensions Mounting drawing with sensor mounting bracket attached. The assembly for the spatter protection hood type (-H) is similar. OTHER SUNX PRODUCTS () () 7 Orange LED 5 (E) (H) (-H) E 9 H ".7 cable m long Sensor unit joining part.5 6(-H) (-H) (-H) (-H) 59 7 (-H),09,0 56(-H),79,9 6(-H),9,5

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. SERIES Color Detection Sensor Reliable and Precise Color Discrimination Marked Conforming to EMC Directive Red, Green and Blue LEDs incorporates red, green and blue LEDs as its beam sources, which promise

More information

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button FZ- SERIES Color Detection Sensor N output type available Timer Reliable and precise color discrimination FX-30 Conforming to EMC Directive UL Recognition FZ- FX-A FX-3 FX-CH Color Detection Analog Output

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

panasonic-electric-works.net/sunx Machine safeguarding without sacrificing productivity

panasonic-electric-works.net/sunx Machine safeguarding without sacrificing productivity 533 PHOTO PHOTO Ultra-slim Curtain Type 4 SERIES Related Information General terms and conditions... F-17 SF-C10... P.633~ General precautions... P.1405 selection guide... P.511~ Glossary of terms... P.1359~

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification Date: 2014.6.12 Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification RoHS Symbol Amended Reason Pages Date Amended by Ref.No Approved by Checked by Drawn by Designed by Title UST-10LX

More information

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5 SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

SA1J-F: Full Color Fiber Optic Sensors

SA1J-F: Full Color Fiber Optic Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain ice: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com This new line of full color sensors offers

More information

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type. INSTRUCTI MANUAL Sensor High-performance Digital Display DP-1 Series Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

AUTOMATIC SETTING TYPE OPTICAL FIBER PHOTOELECTRIC SENSORS. Long Sensing Range. The standard M4 fiber offers the sensing range of 600mm inch.

AUTOMATIC SETTING TYPE OPTICAL FIBER PHOTOELECTRIC SENSORS. Long Sensing Range. The standard M4 fiber offers the sensing range of 600mm inch. AUTOMATIC TING TYPE OPTICA FIBER PHOTOEECTRIC SENSORS UZF Series COMPACT SIZE WITH ADVANCED SENSING TECHNOOGY Thickness : mm inch Just mm inch thick. Even a number of UZF amplifiers save space. Only mm

More information

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No. 6 HPX-T Series Au-tuning Fiber Optic Phoelectric Control Specifications FEATURES Built-in Au-tuning Aumatically Adjusts Scanning Characteristics. Adjustment Steps, Results and Scanning Conditions Digitally

More information

Ø50mm Shaft Multi-Turn Absolute Type

Ø50mm Shaft Multi-Turn Absolute Type Ø50mm Shaft Multi-Turn Absolute Type Diameter Ø50mm Shaft Type Multi-Turn Absolute otary Encoder Features Total 23-bit resolution (8388608-division) of 10-bit single-turn (1024-division) and 13-bit multi-turn

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Electrical connection

Electrical connection Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Self--powered Time Counter

Self--powered Time Counter Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to

More information

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating UV Power Monitor Monitor the Output of a UV Light Source through an Optical Fiber Cable Head Unit withstands temperatures of up to 300 C. Easy-to-read digital display of measurement values. Harmful UV

More information

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use Digital Fiber Amplifier Digital Fiber Amplifier Provides High Performance and Ease of Use First amplifier to offer three user-selectable displays: digital level, percentage and analog display Flashing

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type F71series Manual setting Fiber optic sensors Adjacent installation of up to 8 units - Proprietary Anti Interference feature is used - High-accuracy-8-turn sensitivity adjustment - Position indicator is

More information

F3SG-RA. Safety Light Curtain. Advanced Safety Light Curtain in Rugged, IP67 Rated Housing. Online. Blanking

F3SG-RA. Safety Light Curtain. Advanced Safety Light Curtain in Rugged, IP67 Rated Housing. Online. Blanking Safety Light Curtain F3SG-RA Advanced Safety Light Curtain in Rugged, IP67 Rated Housing Rugged, IP67 rated housing resists washdown Space-saving slim profile of 35x35 mm (1.37 in.) Scan code with smart

More information

Type F70AB F70ABPN. Digital display. Simple operation featured

Type F70AB F70ABPN. Digital display. Simple operation featured F70Aseries Digital display Fiber optic sensors Digital indication of sensing information Simple operation for setting functions Direct reading of stablility level is available along with received light

More information

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features R Self -P owered Count Totalizer Subminiature Total Counters With Improved Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H PNP/NPN DC voltage input

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance 19 Digital SERIES General terms and conditions... P.1 Related Information FX-CH2 / SC-GU1-485...P.199 / P.201 ~ Korea s S-mark... P.104~ Sensor selection guide P.11~ / P.61~ Glossary of terms / General

More information

Safety Light Curtain Type4 SIL3 PLe

Safety Light Curtain Type4 SIL3 PLe Maximum safety standard Type4 SIL3 PLe Safety Light Curtain GL-R Series Unmatched Protection! Safety Light Curtain Strong Smart Simple GL-R Series SAFETY LIGHT CURTAINS DESIGNED FOR ANY APPLICATION RECESSED

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) All seven laser types provide ample long distance, for the Diffuse Reflective Model 1.000 mm and for Retroreflective

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication

More information

USER S MANUAL. FX2N-8AD Analog input block

USER S MANUAL. FX2N-8AD Analog input block USER S MANUAL FX2N-8AD Analog input block FX2N-8AD Analog input block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation

More information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance NEW Safety Light Curtain MS4800 Series Strong, Durable Body and Long, 20-m Sensing Distance A Powerful Safety Light Curtain with Durable, Impact-resistant Body and Long, 20-m Sensing Distance Has Arrived.

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

Sensors. SA1J: Full Color Recognition Sensors. General Specifications. Q-4 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC

Sensors. SA1J: Full Color Recognition Sensors. General Specifications. Q-4   USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC SA1J: Full Color Recognition SA1J: Full Color Recognition Introducing a cost-effective solution for full color sensing applications IDEC s SA1J full color recognition sensor. Outstanding benefits of the

More information

Super Side. Sense type

Super Side. Sense type Front ense type Photoelectric ensor Photoelectric ensor series uper ide ense type uper ide-sense Type projects the beam from the mm (.9 inch) of wide edge of the sensor. M pig-tail connector types are

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

F70series. Variation. Excellent detection performance

F70series. Variation. Excellent detection performance F70series Digital display Fiber optic sensors Digital indication of sensing information arious advanced functions provide for optimum use of the sensor Unparalleled high resolution allows highly accurate

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 310 mm Laser class 1, red, 655 nm, acc.

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing en 02-2014/05 50109619-01 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

L-GAGE Laser Gauging Sensors

L-GAGE Laser Gauging Sensors Class 2 Visible Laser isplacement Sensor with Both Analog and iscrete (Switched) Outputs Features Patent Pending Self-contained Class 2 modulated visible laser gauging sensor needs no separate controller

More information

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global Contact-Type Digital Displacement Sensor HG-S Series User's Manual WUME-HGS-4 2017.1 panasonic.net/id/pidsx/global (MEMO) 2 Panasonic Industrial Devices SUNX Co., Ltd. 2017 Thank you for purchasing an

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.

More information

V 180 Series Photoelectric Switches

V 180 Series Photoelectric Switches D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal

More information

LED Type Optical Displacement Sensor

LED Type Optical Displacement Sensor LED Type Optical Displacement Sensor User s Manual Sensor head LH-50 series General purpose controller LH-CL6, LH-CL6P First Edition Contents Contents 1. INTRODUCTION...1 2. CHECKING PACKED ITEMS...3 CHAPTER

More information

Electrical connection

Electrical connection Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 610 mm Laser class 1, red, 655 nm, acc.

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

SPACESCAN SERIES SS 02

SPACESCAN SERIES SS 02 Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc

More information

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1. Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options

More information

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc

More information

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body Beta TX Datasheet Beta-TX The Beta-TX is a complete self contained laser diode system which can operate in both CW and modulation modes. The Beta- TX features high speed modulation with a bandwidth of

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-LIGHT K30L Series With Independent Push Button Contact EZ-LIGHT K0L Series With Independent Push Button Contact Datasheet Compact with One, Two, or Three s and a Momentary Push Button Output Rugged, cost-effective and easy-to-install multicolor indicator light

More information

LH1D Series Surface Mount Indicators

LH1D Series Surface Mount Indicators Jumbo Dome LH1D Series Surface Mount Indicators IDEC LED Spider (100506) Excellent Visibility From the front and the side. New ø66 Jumbo Dome Ideal for Mounting on IP67 Protection Can be used in environments

More information

Type SCH94FO. Type SCH94FO. Description

Type SCH94FO. Type SCH94FO. Description Type SCH94FO Hollow Shaft Fiber Optic Encoder - Ø 94 mm Dual Output Option (Digital & Fiber Optic) Fiber Optic Transmission up to 2,000 meters (~ 1.25 miles) No Degradation of Encoder Signal from Electrical

More information

Instruction Manual SF4B- -01<V2> Light Curtain / Type panasonic.net/id/pidsx/global

Instruction Manual SF4B- -01<V2> Light Curtain / Type panasonic.net/id/pidsx/global Light Curtain / Type4 SF4B- -01 Instruction Manual WUME-SF4B01V2-13 Conforming to the examination of Japanese Ministry of Health, Labor and Welfare. Press machines : Model Examination No. TA524 (SF4B-F,-H),No.

More information

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets MicroSafe MCF4700 C US File No. LR90200 MicroSafe Flexible MCF4700-12, MCF4700-20, MCF4700-30 12 mm, 20 mm and 30 mm resolution versions Compact segmented light curtain 1.02 inch (26 mm) x 1.1 inch (28

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Self-powered Totalizer

Self-powered Totalizer Self-powered Totalizer New H7E Compact Economical Totalizer with High Visibility Available with Backlit LCD Display Large display with 8.6-mm character height. Includes new models with backlight for improved

More information

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved

More information

W100L: Laser Sensor in Mini- Format

W100L: Laser Sensor in Mini- Format Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

Detect Color and Shape for various inspection

Detect Color and Shape for various inspection CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view

More information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available

More information

GC30 Digital Differential Pressure Gauge Operation Manual

GC30 Digital Differential Pressure Gauge Operation Manual TY-GC30-001A GC30 Digital Differential Pressure Gauge Operation Manual NAGANO KEIKI CO., LTD 2004.02.12 For safety of use TY-GC30-001A In order to safely and correctly utilize this device, please read

More information

Interface Connectors for Miniature, Portable Terminal Devices

Interface Connectors for Miniature, Portable Terminal Devices NEW Interface Connectors for Miniature, Portable Terminal Devices ST Series Strong locking mechanism Right Mating direction Left Top 9N max. Overview Developed as external input/output connectors for the

More information

SH2RE16A4. Output relay module. Benefits. Description

SH2RE16A4. Output relay module. Benefits. Description Output relay module Benefits Integrated system. Dupline is the brand name for Carlo Gavazzi s 2-wire bus system. Cost reduction. The use of a bus system is a proven way to reduce installation costs - especially

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Warner Photoscanner MCS-500 Series LED Photoelectric Control Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre

More information

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151 Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Amplifier for fiber optics. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing Amplifier for fiber optics Dimensioned drawing up to 525mm up to 120mm 10-30 V DC 3-digit display for indicating and setting the switching threshold NEW: AutoSet function for easy sensor adjustment Menu

More information