59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.
|
|
- Kristian Clark
- 6 years ago
- Views:
Transcription
1 .1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA, CE, ARI, RoHS UL, IEC EN 60947, CE, CSA, RoHS UL, IEC EN 60947, CE, CSA, RoHS Technical Data Pole configurations 1P, 2P, 3P, 4P 3P, 4P 3P, 4P Inductive Amp ratings To 360A To 8.8A (AC-3) To 1600A (AC-3) Resistive Amp ratings To 360A To 20A (AC-1) To 2450A (AC-1) Typical electrical operations To 300,000 To 750,000 To 1,400,000 For our complete product offering, see Volume 5 Motor Control and Protection, CA E. 64 Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
2 Motor Control and Protection.1 Compact Definite Purpose Product Selection Compact Definite Purpose Open Type Ampere Ratings Inductive Full Load Single-Pole Resistive Magnet Coil Selection Locked Rotor V Catalog Number C25ANB130_ C25ANB140_ Single-Pole with Shunt C25CNB130_ C25CNB140_ Two-Pole C25BNB225_ C25BNB230_ C25BNB240_ AC Coil Voltage 50/60 Hz Coil Suffix 24 T A B Notes Rating per pole. Replace underscore (_) in catalog number with coil suffix letter from table at left. Features Insulation voltage: 690V Current rated and hp/kw rated Magnet coil: Class F, 155 C Contact arc covers are standard on all contactors Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
3 .1 Motor Control and Protection Catalog Number Selection Definite Purpose Definite Purpose Model C = Contactor A = Three-phase starter B = Single-phase starter Note Not available on 50A devices. Type 25 = Non-reversing contactors 27 = Non-reversing starters 29 = Non-reversing starters 65 = Reversing contactors Contactor Frame Size A = Compact, single-pole B = Compact, two-pole C = Compact, single-pole w/shunt D = 15 50A, two- and three-pole E = 25 40A, four-pole F = 60 75A, two- and three-pole G = 90A, two- and three-pole H = 120A, two- and three-pole K = 200 and 300A, three-pole L = 360A, three-pole For Starters Only C = Common control wiring S = Separate control wiring Enclosure Type N = Open with metal mounting plate R = Open with DIN rail mounting adapter (two- and three-pole, 15 50A contactors only) G = NEMA Type 1 Enclosed C 2 5 D N A A A Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole 4 = Four-pole A = Vac, 50/60 Hz B = Vac, 50/60 Hz C = Vac, 50/60 Hz D = Vac, 50/50 Hz H = 277 Vac, 60 Hz J = Vac, 50/60 Hz L = Vac, 50 Hz Auxiliary Contacts (Side Mount) A = 1NO pressure plate B = 1NC pressure plate C = 1NO-1NC pressure plate L = 1NO-1NC snap switch QC only M = 2NO-2NC snap switch QC only 15 = 15A 25 = 25A 30 = 30A 40 = 40A Coil Selection Current Rating 50 = 50A 60 = 60A 75 = 75A 90 = 90A R = 12 Vac, 50/60 Hz T = 24 Vac, 50/60 Hz 1R = 12 Vdc 1T = 24 Vdc 1W = 48 Vdc 1A = 120 Vdc 120 = 120A 200 = 200A 300 = 300A 360 = 360A Power Terminals A = Binding head screw B = Binding head screw and quick connect terminals (side-by-side) C = Screw/pressure plate D = Screw/pressure plate and quick connect terminals (side-by-side) E = Box lugs (posidrive setscrew) F = Box lugs (posidrive setscrew) and quick connect terminals (side-by-side) G = Binding head screw and quick connect terminals (vertical in-line) H = Screw/pressure plate and quick connect ZZ terminals (vertical in-line) J = Box lugs (posidrive setscrew) and quick connect terminals (vertical in-line) K = Box lugs (hex socket allen head setscrew) L = Box lugs (hex socket allen head setscrew) and quick connect terminals (side-by-side) M = Box lugs (hex socket allen head setscrew) and quick connect terminals (vertical in-line) 66 Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
4 Motor Control and Protection.1 50 mm C25 Definite Purpose Features Product Selection 50 mm C25 Definite Purpose C25 Open Type Rating, Amperes Inductive Full Load Magnet Coil Selection Resistive per Pole Line Voltage Locked Rotor Notes Replace underscore (_) in catalog number with magnet coil suffix from table at left. Carton quantities including 20 individually packaged units are available for two- and three-pole units through 60A inductive. are dual-rated with inductive and resistive ratings, as well as horsepower and kilowatt ratings rated 15 50A are available with DIN rail mount as a factory installed option Magnet coil: Class B (C25E, F, G, H and K), 130 C Ambient temperature: 150 F (65 C) maximum Maximum Motor Horsepower Open Type with Metal Mounting Plate Open Type with DIN Rail Adapter Single-Phase Three-Phase Catalog Number Catalog Number C25DND315_ C25DRD315_ /2 C25DND325_ C25DRD325_ C25END425_ C25DND330_ C25DRD330_ C25END430_ /2 10 C25DNF340_ C25DRF3340_ C25ENF440_ C25DNJ350_ C25DRJ350_ C25FNF360_ C25FNF375_ Voltage 60 Hz 50 Hz AC T A B DC 24 1T Coil Suffix Class H AC coils available as option for 15 50A contactor. Add 2 before AC coil suffix letter. Available through 120A V 50/60 Hz for 60A, 75A and all four-pole contactors (25 40A). with DC coils (only available up to 75A) include an early break NC auxiliary contact, C320KGD1. Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
5 .1 Motor Control and Protection Reversing and Two-Speed Open Type Unwired, Mechanically Interlocked Only Rating, Amperes Inductive Full Load Resistive per Pole Magnet Coil Selection Line Voltage Locked Rotor Maximum Motor Horsepower Notes Replace underscore (_) with magnet coil suffix from table at left. Class H AC coils available as option for 15 50A contactor. Add 2 before AC coil suffix letter V 50/60 Hz for 60A, 75A. Available through 50A. Open Type with Metal Mounting Plate Single-Phase Three-Phase Catalog Number C65DND315_ /2 C65DND325_ C65DND330_ /2 10 C65DNF340_ C65DNJ350_ Voltage 60 Hz 50 Hz T A B Coil Suffix Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
6 Motor Control and Protection.1 XT IEC Miniature Catalog Number Selection XT IEC Miniature Miniature Designation XT = XT IEC power control Product Selection Full Voltage Non-Reversing Miniature Operational Current AC-3 Amp Rating 380/400V Conventional Free Air Thermal Current AC-1 at 50 C Magnet Coil Suffix Type MC = Three-pole FVNR mini IEC contactor Maximum kw Ratings AC-3 IEC Utilization Categories AC-1: Non-inductive or slightly inductive loads. AC-3: Squirrel cage motors starting, switching of motors during running. AC-4: Squirrel cage motors starting, plugging, inching. Features XT MC 6 A 10 A Current Rating, AC-3 XTMC 6 = 6.6A 9 = 8.8A Reversing or non-reversing Three- and four-pole configurations Three-pole XTMC Four-pole XTMF Panel or DIN rail mounting IP20 finger and back-of-hand proof Direct mount with XTOM miniature overload relays Maximum Three-Phase Motor Ratings Integral Auxiliary Contact 01 = 1NC 10 = 1NO Three-Phase Motors, Hz Single-Phase hp Ratings Three-Phase hp Ratings V V 550V 660/690V 115V 200V 230V 200V 230V 460V 575V Notes Underscore (_) indicates magnet coil suffix required. See table at left. With DC operation: Integrated diode resistor combination, coil rating 2.6W. Coil Codes A = 110V 50 Hz, 120V 60 Hz B = 220V 50 Hz, 240V 60 Hz T = 24V 50/60 Hz TD = 24 Vdc Number of Power Auxiliary Poles Contacts Catalog Number Screw Terminals /4 3/ / NO XTMC6A10_ /4 3/ / NC XTMC6A01_ / / NO XTMC9A10_ / / NC XTMC9A01_ / / XTMF9A00_ Coil Voltage 110V 50 Hz, 120V 60 Hz 220V 50 Hz, 240V 60 Hz 24V 50/60 Hz 24 Vdc TD 415V 50 Hz, 480V 60 Hz 550V 50 Hz, 600V 60 Hz 208V 60 Hz Suffix Code A B T C D E Frame Size A = 45 mm mini Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
7 .1 Motor Control and Protection Accessories Front Mount Auxiliary Contacts Conventional Free Air Thermal Current, I th = I e, AC-1 in Amps Contact Configuration XT IEC Miniature Contact Sequence Package Qty. Catalog Number Screw Terminals 10 1NO-1NC XTMCXFA NO-2NC XTMCXFA NO-1NC XTMCXFA NO XTMCXFA40 Description Package Qty. Catalog Number Mechanical interlock 5 XTMCXML Reversing link kit main current wiring for reversing contactors and starters Connector for mechanically arranging contactors and timing relays in combinations XTMCXRL 50 XTMCXCN Notes For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted, the distance between contactors is 0 mm, and the mechanical lifespan is 2.5 x 106 operations. The following control cables are integrated as part of the electrical interlock: K1M: A1 K2M: 21; K1M: 21 K2M: A1. Reversing link kit does not include mechanical interlock. 0 mm distance between contactors Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
8 Motor Control and Protection.1 XT IEC Catalog Number Selection XT IEC Designation XT = XT line of IEC control Type CE = Three-pole FVNR IEC contactor CS = Three-pole FVNR S Series IEC contactor 007 = 7A 009 = 9A 012 = 12A 015 = 15A 018 = 18A 025 = 25A 032 = 32A 040 = 40A 050 = 50A 065 = 65A 072 = 72A Features XT CE 007 B 01 A Current Ratings, AC = 80A 095 = 95A 115= 115A 150 = 150A 170 = 170A 185 = 185A 225 = 225A 250 = 250A 300 = 300A 400 = 400A 500 = 500A Reversing or non-reversing contactors AC-3 contactor ratings to 1600A and AC-1 contactor ratings to 2000A Panel or DIN rail mounting to 65A IP20 finger and back-of-hand proof Built-in NO or NC auxiliary contacts to 32A Built-in surge suppression on DC coils XTCE Frame B-G and AC or DC coils on XTCE Frame L-R Can be used with XT or C396 overload relays Can be used with XTPR MMPs for manual motor controllers or UL508 Type F combination motor controllers 570 = 570A 580 = 580A 650 = 650A 750 = 750A 820 = 820A C10 = 1000A C14 = 1400A, AC-1 C16 = 1600A, AC-3 C20 = 2000A, AC-1 B = 45 mm C = 45 mm D = 55 mm F = 90 mm G = 90 mm Built-In Auxiliary Contact 01 = 1NC 10 = 1NO Coil Codes See Page = 0NO 0NC 22 = 2NO 2NC Frame Size Designation L = 140 mm M = 160 mm N = 250 mm P = 260 mm R = 515 mm Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
9 .1 Motor Control and Protection Product Selection Full Voltage Non-Reversing Three-Pole, Frames B G UL/CSA Ratings UL General Purpose Amp Rating Frame B Notes The 7 32A XTCE contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules. The 40 65A XTCE contactors have positively driven contacts within the auxiliary contact module. Six auxiliary contacts are possible with a combination of side mounted and front mount auxiliary contacts. DC operated contactors (Frames B G, 7 150A) have a built-in suppressor circuit. Frames B C contactors with 1NC built-in auxiliary are mirror contacts (XTCE B01_ XTCE C01_). Underscore (_) indicates magnet coil suffix required. See Page 74. For spring cage terminals, insert C after the fourth digit of the catalog number. Example: XTCE C 007B10A. For 7 12A XTCEC contactors, the power, auxiliary and coil terminals are spring cage. For 18 32A XTCEC contactors, the auxiliary and coil terminals are spring cage. For A XTCEC contactors, the coil terminals only are spring cage. For electrical life contactor application data, see Volume 5 Motor Control and Protection, CA E, Tab 27. For A, use 2 x 3/0 AWG wire. For A, use 2 x 70 mm2 wire. IEC Ratings AC-1 Maximum kw Ratings AC-3 Single-Phase hp Ratings Three-Phase hp Ratings AC-3 (40 C) Three-Phase Motors Hz 115V 200V 230V 200V 230V 460V 575V I e (A) I e = I th (A) 220/230V 380/400V 415V 660/690V Auxiliary Contacts Catalog Number Screw Terminals 20 1/4 3/ / NO XTCE007B10_ 20 1/4 3/ / NC XTCE007B01_ 20 1/ / / NO XTCE009B10_ 20 1/ / / NC XTCE009B01_ NO XTCE012B10_ NC XTCE012B01_ NO XTCE015B10_ NC XTCE015B01_ Frame C NO XTCE018C10_ NC XTCE018C01_ / NO XTCE025C10_ / NC XTCE025C01_ NO XTCE032C10_ NC XTCE032C01_ Frame D / XTCE040D00_ / XTCE050D00_ XTCE065D00_ XTCE072D00_ Frame F / XTCE080F00_ / XTCE095F00_ Frame G XTCE115G00_ XTCE150G00_ XTCE170G00_ 72 Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
10 Motor Control and Protection.1 Full Voltage Non-Reversing Three-Pole, Frames L R UL/CSA Ratings UL General Purpose Amp Rating Contactor Application Data IEC Ratings AC-1 Maximum kw Ratings AC-3 Three-Phase hp Ratings AC-3 (40 C) Three-Phase Motors Hz 200V 230V 460V 575V I e (A) I e = I th (A) 220/230V 380/400V 415V 660/690V 1000V Frame L Standard Coil (110/120V, 230/240 Vac Coil Only) Notes AC and DC operated contactors have a built-in suppressor circuit (Frames L R, A). For A contactors at 660/690V or 1000V: Do not reverse directly. Underscore (_) indicates magnet coil suffix required. See Page 74. When operating the A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test see Pub51204, Pub Auxiliary Contacts Catalog Number NO-2NC XTCS185L22_ NO-2NC XTCS225L22_ NO-2NC XTCS250L22_ Frame L Electronic Coil NO-2NC XTCE185L22_ NO-2NC XTCE225L22_ NO-2NC XTCE250L22_ Frame M Standard Coil (110/120V, 230/240 Vac Coil Only) NO-2NC XTCS300M22_ NO-2NC XTCS400M22_ NO-2NC XTCS500M22_ NO-2NC XTCS570M22_ Frame M Electronic Coil NO-2NC XTCE300M22_ NO-2NC XTCE400M22_ NO-2NC XTCE500M22_ NO-2NC XTCE570M22_ Frame N Electronic Coil NO-2NC XTCE580N22_ NO-2NC XTCE650N22_ NO-2NC XTCE750N22_ NO-2NC XTCE820N22_ NO-2NC XTCEC10N22_ Frame P Electronic Coil NO-2NC XTCEC14P22_ Frame R Electronic Coil NO-2NC XTCEC16R22_ NO-2NC XTCEC20R22_ Catalog Prefix XTCE012B XTCE015B XTCE018C Electrical Life (Operations) for 10 hp, 480V (14.2A) Applications 1 million 1.2 million 2 million Full Voltage Non-Reversing Three-Pole Contact Sequence (Circuit Symbols), Standard Offering Contactor Frame Auxiliary Contacts Contact Sequence B C B C 1NO 1NC D G L R 2NO-2NC A A A A A A A A Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
11 .1 Motor Control and Protection Magnet Coil Suffix Coil Voltage Suffix Code Frames B F 110V 50 Hz, 120V 60 Hz A 220V 50 Hz, 240V 60 Hz B 24V 50/60 Hz T 24 Vdc TD 415V 50 Hz, 480V 60 Hz C 550V 50 Hz, 600V 60 Hz D 208V 60 Hz E Frame G V 50/60 Hz A V 50/60 Hz B Coil Voltage Suffix Code Frames L N V Hz/DC A V Hz C Vdc TD Frames L M, S-Series V 50/60 Hz A V 50/60 Hz B Frames P R V Hz/DC B 24V 50/60 Hz T Vdc TD V 50/60 Hz C XTCR Reversing Contactor Components Qty. Frame B C D F G 2 Contactor XTCE B01_ XTCE B01_ XTCE D00_ XTCE F00_ XTCE G00_ 2 Auxiliary contact XTCEXFAC20 XTCEXFAC20 XTCEXFBG11 XTCEXFBG11 XTCEXFBG11 1 Mechanical interlock XTCEXMLB XTCEXMLC XTCEXMLD XTCEXMLG XTCEXMLG 1 Reversing link kit XTCEXRLB XTCEXRLC XTCEXRLD XTCEXRLG XTCEXRLG 74 Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
12 Motor Control and Protection.1 Accessories Frames B C Frame B Frame C Frames D G Auxiliary Contacts Frames B G Conventional Thermal Current, Open at 60 C I th = I e, AC-1 in Amps Poles Frames B C Front (Top) Mount Contact Configuration Circuit Symbol Pkg. Qty. Notes Interlocked opposing contacts, to IEC/EN Annex L (positively driven), within the auxiliary contact modules (not NO [early make] and NC [late break] contacts) and for the built-in auxiliary contacts of the XTCE007_ XTCE032_ Auxiliary break contact can be used as mirror contact to IEC/EN Annex F (not NC [late break] contact). No auxiliary contacts can be fitted between two contactors. Frames B C cannot use both a side AND a top mount auxiliary contact at the same time. Can be mounted to the left side of contactor only. Cannot be used in combination with front (top) mount auxiliary contacts or mechanical interlocks. For Frame D, six auxiliary contacts maximum (can be a combination of side and top mount units). Catalog Number Screw Terminals NO XTCEXFAC NO-1NC XTCEXFAC NO XTCEXFAC NO-2NC XTCEXFAC22 Frame B Side Mount NO 53 1 XTCEXSAB NC 51 1 XTCEXSAB01 Frame C Side Mount NO-1NC XTCEXSCC11 Frames D G NO XTCEXFBG NO-1NC XTCEXFBG NO-0NC XTCEXFBG NO-2NC XTCEXFBG Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
13 .1 Motor Control and Protection Frames D R Frames L R XTCEXMLB XTCEXMLC XTCEXMLM Reversing Link Kits Side Mount Auxiliary Contacts Frames D R, A Conventional Free Air Thermal Current, I th = I e, AC-1 in Amps Frame D R Mechanical Interlock Reversing Link Kits Notes Poles Contact Configuration Circuit Symbol Pkg. Qty. Catalog Number Screw Terminals NO-1NC XTCEXSBN11 Frames L R (Screw Mount) NO-1NC XTCEXSBR11 For Use with Package Qty. Catalog Number XTCE007B XTCE015B, XTCF020B 5 XTCEXMLB XTCE018C XTCE032C 1 XTCEXMLC XTCF032C XTCF045C XTCE040D XTCE072D XTCF063D XTCF080D 1 XTCEXMLD XTCE080F XTCE170G 1 XTCEXMLG XTCF125G XTCF200G XTCE185L XTCE570M 1 XTCEXMLM XTCE580N XTCEC10N 1 XTCEXMLN XTCE500M XTCE570M with XTCE500N XTCEC10N 1 XTCEXMLNM For Use with Package Qty. Catalog Number XTCE007B XTCE015B 1 XTCEXRLB XTCE018C XTCE032C 1 XTCEXRLC XTCE040D XTCE065D 1 XTCEXRLD XTCE080F XTCE150G 1 XTCEXRLG XTCE185L XTCE250L 1 XTCEXRLL XTCE300M XTCE400M 1 XTCEXRLM400 For Frame D, six auxiliary contacts maximum (can be a combination of side and top mount units). For Frames F R, eight auxiliary contacts maximum (can be a combination of side and top mount units). For two contactors with AC or DC operated magnet system which are horizontally or vertically mounted. For B G frames, mechanical lifespan is 2.5 x 106 operations and the distance between contactors is 0 mm. For L N frames, mechanical lifespan is 5 x 106 operations and no auxiliary contact can be mounted between the mechanical interlock and the contactor the distance between contactors is 15 mm. XTCEXMLG, XTCEXMLN and XTCEXMLNM consist of an interlock element and mounting plate. Also includes interlocking bridge (XTCEXLBB). The following control cables are integrated for electrical interlock: K1M: A1 K2M: 21; K1M: 21 K2M: A1; K1M: A2 K2M: A Volume 9 OEM Product Guide CA E February For Immediate Delivery or Tech Support call KMParts.com at (866)
14 Index A AC, 1-2, 4-10, Accessories, 7, 12 Adapter, 4 adapter, 3 Add, 4-5 after, 9 Air, 6-7, 13 all, 2, 4 allen, 3 Also, 13 also, 10 Ambient, 4 Amp, 1, 6, 9-10 Ampere, 2 Amperes, 4-5 Amps, 7, an, 4, 13 ANB, 2 AND, 12 and, 1-13 Annex, 12 Application, 10 application, 9 Applications, 10 Approvals, 1 arc, 2 are, 2, 4, 7, 9, 13 ARI, 1 arranging, 7 as, 4-5, 7, 9, 12 at, 1-13 Auxiliary, 3, 6-13 auxiliary, 4, 8-9, Available, 4-5 available, 3-5 AWG, 9 B back, 6, 8 be, 8, 10, before, 4-5 between, 7, 9, Binding, 3 BNB, 2 both, 12 Box, 3 break, 4, 12 bridge, 13 Built, 8 built, 9-10, 12 by, 3
15 Index C CA, 1-13 cables, 7, 13 cage, 6, 9 call, 1-13 Can, 8, 12 can, Cannot, 12 cannot, 12 Carton, 4 Catalog, 2-10, catalog, 2, 4, 9 Categories, 6 CE, 1, 8 Circuit, 10, circuit, 9-10 Class, 2, 4-5 CNB, 2 Code, 6, 11 Codes, 6, 8 Coil, 2-6, 8, coil, 2, 4-6, 9-10 coils, 4-5, 8 com, 1-13 combination, 6, 8-9, combinations, 7 Common, 3 Compact, 2-3 complete, 1 Components, 11 Configuration, 7, configurations, 1, 6 connect, 3 Connector, 7 consist, 13 Contact, 2, 6-8, 10, contact, 4, 9, Contactor, 3, contactor, 4-6, 8-9, 12-13, 1-13 contactors, 2-4, 7-10, Contacts, 3, 6-7, 9-10, contacts, 8-9, Control, 1-13 control, 3, 6-8, 13 controllers, 8 Conventional, 6-7, covers, 2 CS, 8 CSA, 1, 9-10 Current, 2-3, 6-8, current, 7 CXTCE, 13 D Data, 1, 10 data, 9 DC, 4, 6-11, 13 dc, 6 Defi, 4 Definite, 1-4 Delivery, 1-13 Description, 1, 7 Designation, 6, 8 devices, 3 digit, 9 DIN, 3-4, 6, 8 diode, 6 Direct, 6 directly, 10 distance, 7, 13 DND, 4-5 DNF, 4-5 DNJ, 4-5 Do, 10 does, 7 DRD, 4 DRF, 4 driven, 9, 12 DRJ, 4 dual, 4 during, 6 E early, 4, 12 eaton, 1-13 eight, 13 Electrical, 10 electrical, 1, 7, 9, 13 Electronic, 10 element, 13
16 Index EN, 1, 12 Enclosed, 3 Enclosure, 3 END, 4 ENF, 4 Example, 9 F factory, 4 Features, 2, 4, 6, 8 February, 1-13 finger, 6, 8 fitted, 12 FNF, 4 following, 7, 13 For, 1-13 for, 4-5, 7-8, 10, Four, 3, 6 four, 3-4, 6 fourth, 9 Frame, 3, 6, 8-13 Frames, 9-13 frames, 13 Free, 6-7, 13 frequency, 10 from, 2, 4-5 Front, 7, 12 front, 9, 12 Full, 2, 4-6, 9-10 FVNR, 6, 8 G General, 9-10 Guide, 1-13 H hand, 6, 8 have, 9-10 head, 3 hex, 3 high, 10 horizontally, 7, 13 Horsepower, 4-5 horsepower, 4 hp, 2, 6, 9-10 Hz, 2-6, 9-11 I Ie, 7, 9-10, IEC, 1, 6-10, 12 Immediate, 1-13 In, 8 in, 2-4, 7-10, inching, 6 include, 4, 7 includes, 13 including, 4 indicates, 6, 9-10 individually, 4 Inductive, 1-2, 4 inductive, 4, 6 insert, 9 installed, 4 Insulat, 2 Integral, 6 Integrated, 6 integrated, 7, 9, 13 Interlock, 13 interlock, 7, 11, 13 Interlocked, 5, 12 interlocking, 13 interlocks, 12 inverters, 10 ion, 2 IP, 6, 8 is, 7, 13 Ith, 7, 9-10, 12-13
17 Index K KGD, 4 kilowatt, 4 kit, 7, 11 Kits, 13 KMParts, 1-13 kw, 2, 6, 9-10 L late, 12 left, 2, 4-6, 12 letter, 2, 4-5 Life, 10 life, 9 lifespan, 7, 13 Line, 4-5 line, 3, 8 Link, 13 link, 7, 11 Load, 2, 4-5 load, 10 loads, 6 Locked, 2, 4-5 lugs, 3 M Magnet, 2, 4-6, 11 magnet, 4-7, 9-10, 13 main, 7 make, 12 manual, 8 Maximum, 4-6, 9-10 maximum, 4, MC, 6 Mechanical, 7, 11, 13 mechanical, 7, Mechanically, 5 mechanically, 7 Metal, 4-5 metal, 3 million, 10 mini, 6 Miniature, 1, 6-7 miniature, 6 mirror, 9, 12 mm, 4, 6-9, 13 MMPs, 8 Model, 3 module, 9 modules, 9, 12 Motor, 1-13 motor, 8 Motors, 6, 9-10 motors, 6 Mount, 3, 7, mount, 4, 6, 9, mounted, 7, 9, Mounting, 4-5 mounting, 3, 6, 8, 13 must, 10 N NC, 3-4, 6-10, NEMA, 3 nite, 4 NO, 3, 6-10, No, 12 no, 13 Non, 3, 6, 9-10 non, 6, 8 Not, 3 not, 7, 10, 12 Note, 3 Notes, 2, 4-7, 9-10, Number, 2-10, number, 2, 4, 9 O OEM, 1-13 of, 3, 6-9, 12-13
18 Index Offering, 10 offering, 1 oltage, 4 on, 2-3, 8, 10 Only, 3, 10 only, 3-4, 9, 12 OnlyOpen, 5 Open, 2-5, 12 operated, 7, 9-10, 13 operating, 10 operation, 6 Operational, 6 Operations, 10 operations, 1, 7, 13 opposing, 12 option, 4-5 or, 1-13 our, 1 overload, 6, 8 Overview, 1 P Package, 7, 13 packaged, 4 Page, 1, 8-10 Panel, 6, 8 part, 7 per, 2, 4-5 performing, 10 Phase, 4-6, 9-10 phase, 3 Pkg, Plate, 4 plate, 3, 13 platea, 3 plateb, 3 PlateInductive, 5 plugging, 6 Pole, 1-2, 4-5, 9-10 pole, 2-4, 6, 8 polec, 3 polef, 3 polefor, 3 poleh, 3 Poles, 3, 6, posidrive, 3 positively, 9, 12 possible, 9 Power, 3, 6 power, 6, 9 Prefix, 10 pressure, 3 Product, 1-13 product, 1 proof, 6, 8 Protection, 1-13 Pub, 10 Purpose, 1-4, 9-10 purpose, 1 Q QC, 3 Qty, 7, quantities, 4 quick, 3 R Rail, 4 rail, 3-4, 6, 8 rated, 2, 4 Rating, 2-6, 9-10 rating, 6 Ratings, 2, 6, 8-10 ratings, 1, 4, 8 re, 4 Recognized, 1 relays, 6-8 removed, 10 Replace, 2, 4-5 required, 6, 9-10 Resistive, 1-2, 4-5 resistive, 4 resistor, 6 reverse, 10 Reversing, 3, 5-11, 13 reversing, 3, 6-8 RoHS, 1 Rotor, 2, 4-5 running, 6
19 Index S same, 12 Screw, 3, 6-7, 9, screw, 3 See, 6, 8-10 see, 1, 9-10 Selection, 1-6, 8-9 Separate, 3 Sequence, 7, 10 Series, 8, 11 setscrew, 3 Shunt, 2 shunt, 3 Side, 3, side, 3, 9-10, Single, 2-6, 9 single, 3 Six, 9 six, Size, 3, 6, 8 slightly, 6 snap, 3 socket, 3 Speed, 5 spring, 9 Squirrel, 6 Standard, 10 standard, 2 starter, 3 Starters, 3 starters, 3, 7 starting, 6 Suffix, 2, 4-6, 11 suffix, 2, 4-6, 9-10 Support, 1-13 suppression, 8 suppressor, 9-10 surge, 8 switch, 3 switching, 6 Symbol, Symbols, 10 system, 7, 13 T Tab, 9 table, 2, 4-6 TD, 6, 11 Tech, 1-13 Technical, 1 temperature, 4 Terminals, 3, 6-7, 9, terminals, 3, 9 test, 10 that, 7 The, 7, 9-10, 13 the, 7, 9-10, Thermal, 6-7, Three, 3-6, 8-10 three, 3-4 through, 4-5 time, 12 timing, 7 To, 1 to, 4, 8, 12 Top, 12 top, Two, 2-3, 5 two, 3-4, 7, Type, 1-6, 8 Typical, 1 U UL, 1, 8-10 Underscore, 6, 9-10 underscore, 2, 4-5 units, 4, Unwired, 5 up, 4 Use, 13 use, 9, 12 used, 8, 12 Utilization, 6
20 Index V Vac, 3, 10 Vdc, 3, 6, 11 vertical, 3 vertically, 7, 13 Voltage, 2, 4-6, 9-11 voltage, 2, 10 Volume, 1-13 W well, 4, 9 When, 10 when, 10 which, 13 wire, 9 wiring, 3, 7 wirings, 3 With, 6 with, 2-10, within, 9, 12 www, 1-13 XTCEXRLD, 11, 13 XTCEXRLG, 11, 13 XTCEXRLL, 13 XTCEXRLM, 13 XTCEXSAB, 12 XTCEXSBN, 13 XTCEXSBR, 13 XTCEXSCC, 12 XTCF, 13 XTCR, 11 XTCS, 10 XTMC, 6 XTMCXCN, 7 XTMCXFA, 7 XTMCXML, 7 XTMCXRL, 7 XTMF, 6 XTOM, 6 XTPR, 8 Z ZZ, 3 X XT, 1, 6-8 XTCE, 8-13 XTCEC, 9-10, 13 XTCEXFAC, XTCEXFBG, XTCEXLBB, 13 XTCEXMLB, 11, 13 XTCEXMLC, 11, 13 XTCEXMLD, 11, 13 XTCEXMLG, 11, 13 XTCEXMLM, 13 XTCEXMLN, 13 XTCEXMLNM, 13 XTCEXRLB, 11, 13 XTCEXRLC, 11, 13
1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)
80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...
IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by
More informationXT IEC Power Control Combination Motor Controllers
7 Product Family Overview May 007 Contents Description Page Standards and Certifications............. 7 Catalog Selection................ 76 Product Selection.......... 77 Accessories............... 7
More informationXT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...
XT Line Replacement s.1 Freedom Line............................................ A200 Line............................................... Lighting Contactor Magnetic.2 IEC Contactors and Starters XT Line..................................................3
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD
. Selection XT Relays Product Line Prefix XT = XT IEC power control XT Timers Product Line Prefix XT = XT IEC power control Product Family Code RM = Mini IEC control relay RE = IEC control relay Product
More information.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and
.1 Product Overview.............................................. Relays and Timers.............................................. Miniature Controls.............................................. Contactors
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationAgency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Manual Motor Protectors Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays....................
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationBulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page
3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed
More informationand Refrigeration Institute). CAQ7 Capacitor Switching Contactors
SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic
More informationand Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors
C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More informationBulletin 305 AC Starters
Bulletin 305 AC Starters Bulletin 305 NEMA AC Starters NEMA sizes 0 2 Cost saving design E1 Plus electronic overload relays Compact size Bulletin 305 reversing starters are most commonly used for full-voltage
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationBulletin 190 Compact. Combination Starters
0Circuit reaker ulletin 10 ulletin 10 Compact Combination Starters Power Range 0.1...45 ulletin 10E Modular Eco Starters ulletin 10S Pre-wired Compact Starters Uses ulletin 140M Motor Protectors and ulletin
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationYour order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories
Bulletin 100-M Miniature Contactors Compact Size Uniform Panel Mounting Dimensions Full oltage Non-Reversing and Reversing Contactors 5, 9, and 12 A Contactors Compatible with Bulletin 193-E solid-state
More informationData sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286
CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationAccessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.
NSB00 K ) K ) K ) Auxiliary switch block, Contactors,. kw RT RT RT / front RH-... /0 Contactors,. kw RT RT RT / Surge suppressors RT -.... /, / auxiliary switch block, -phase feeder front RT -G. / terminals
More informationDefinite Purpose Contactors
Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor
More informationBulletin 100-G IEC Contactors
Bulletin 100-G IEC Contactors Bulletin 100 G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking
More informationLC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 100-G IEC Contactors
Bulletin G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking Mechanical latching Meets IEC,
More informationLC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range
More informationProduct Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)
Circuit Breakers BZM Product Information Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) BZM1 & BZM2 & BZM3 Accessories Optimum and Efficient Protection
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationTeSys circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationInterface Relays and Optocouplers Product group picture
Interface Relays and Optocouplers Product group picture /1 ABB Catalog 2CDC 1 004 C0208 Interface Relays and Optocouplers Table of contents Interface Relays and Optocouplers Interface Relays and Optocouplers
More informationContactors and Contactor Assemblies
Terminal designations according to EN 50 012 3RT10 1 contactors Ident. no. 10E 01 Sizes S0 to S12 Terminal designations according to EN 50 012 3RT10 2 to 3RT10 7, 3RT12, 3RT14 contactors 3RT10 1 contactors
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationI r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release
More informationManual Motor Starter Specifcations
Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional
More informationProtection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationCT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL
Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationType Contact form Model
Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationType Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model
Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGP-500 SERIES - Low Voltage
M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to
More informationBulletin 150, 154 Softstarters Quick Selection Table
Bulletin 50, 54 Quick Selection Table Type Current Range Bulletin No. 50 50 50 SMC-3 Controller 85 A SMC-Delta Controller 47 A SMC Flex Controller 54 480 A Soft Start Kickstart Current Limit Dual Ramp
More informationVAT 20 Adjustable Frequency Drive
VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive
More informationPart-Turn Electric Multi-Turn Electric
Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationAF-300 E11 Adjustable Frequency Drive
AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed
More information