RSCC. Load cells. Special features. Data sheet
|
|
- Cordelia Malone
- 6 years ago
- Views:
Transcription
1 RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test report per OIL R60 for class III scales - eets EC requirements as per EN Six wire circuit - Ex protection version (optional) Data sheet Diagram of RSCC load cell Load application (metric thread) Connection cable Load transfer (metric thread) Design: 50 kg to 200 kg Design: 500 kg to 5 t
2 Dimensions (in mm; 1 mm = inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D 24 C B Without adapter for cable protection system 12x1.5 With adapter for cable protection system aximum capacity B C D 50 kg kg kg HB 2
3 Dimensions (in mm; 1 mm = inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D E C B x1.5 Without adapter for cable protection system With adapter for cable protection system aximum capacity B C D E 500 kg t t x2 5 t x2 Cable protection (Option 6 required: with adapter for a cable protection system; customer side cable protection version) Cable protection system*, (provided by customer) comprising: Screwed cable gland* Flexible cable protection tubing* O ring (provided by customer) Unscrew the 12 sleeve and replace with an 12 threaded tube coupling * Supplier such as Flexicon ( 3 HB
4 ounting accessories (to be ordered separately) Dimensions (in mm; 1 mm = inches) Center bearing collar W H D Rigid force transfer G B B F X a.f. H max /H min Emin/Emax aterial: Tempered steel, galvanized roller bearing steel PTFE/bronze corrugated foil ounting accessories just for static and quasistatic applications B aximum capacity Weight (kg) B H7 D F G H W X a.f. 50 kg to 100 kg kg to 1 t t to 5 t x aximum capacity H min H max E min E max B (N m) 50 kg kg kg kg t t t HB 4
5 Specifications Type RSCC ccuracy class as per OIL R 60 Number of load cell verification intervals (n LC ) C aximum capacity (E max ) 50 kg 100 kg 200 kg 500 kg 1 t 2 t 5 t inimum load cell verification interval % of E max (v min ) Nominal (rated) sensitivity (C N ) mv/v 2 Sensitivity tolerance % 0.25 Zero signal mv/v Temperature coefficient of sensitivity (TK C ) 1) % of C n / 10 K Temperature coefficient of zero signal (TK 0 ) (20 C to 40 C) (-10 C to 20 C) Relative reversibility error (d hy ) 1) % of C n Non linearity (d lin ) 1) Creep upon loading (d cr ) over 30 min. Input resistance (R LC ) (nominal) Output resistance (R 0 ) Ω Insulation resistance (R iso ) GΩ/100 V > 2 Reference excitation voltage (U ref ) 5 V Nominal (rated) supply voltage range (B U ) 0.5 to 12 Nominal (rated) amb. temperature range -10 to +40 (B T ) Operating temperature range (B tu ) C -30 to +70 Storage temperature range (B tl ) -50 to +85 Reference temperature (t ref ) 22 Limit load (E L ) 150 Breaking load (E d ) % of E max Relative perm. vibrational stress (F srel ) 70 (oscillation width as per DIN 50100) Nominal (rated) displacement at maximum capacity (s nom ), 0.05 mm mm Weight (G), approx. kg Degree of protection per EN IP 68 (test conditions 1 m water column / 100 h) (IEC 529) Cable length, six wire configuration 7.6 m as standard aterial: easuring body Cable entry Cable sheath stainless steel 2) stainless steel / neoprene PVC 1) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TK C ) are recommended values. The sum of these values is within the cumulated error limits according to OIL R60. 2) s per EN Cable assignment (6 wire configuration) With this cable assignment, the output voltage at the measuring amplifier is positive in the tensile direction when the transducer is loaded. (gray) (black) (white) (blue) (green) (red) (-) Sensing element (-) Excitation (-) Signal (+) Excitation (+) Sensing element (+) Signal (-) Shielding/drain wire, connected to enclosure ground 5 HB
6 Product numbers (overview) RSCC load cells aximum capacity Order no. aximum capacity Order no. 50 kg 1-RSCC3/50KG-1 1 t 1-RSCC3/1T kg 1-RSCC3/100KG-1 2 t 1-RSCC3/2T kg 1-RSCC3/200KG-1 5 t 1-RSCC3/5T kg 1-RSCC3/500KG-1 RSCC load cells, optional versions Order No. K RSCC N Option 1: Design Standard C3 Option 2: ccuracy class C3 (OIL) Option 3: aximum capacity kg kg kg kg t t t N I1/21 I2/21 Option 4: Explosion protection No TEX IECEx+TEX Zone 1/21 + F, intrinsic safe II2G Ex ia IIC T6/T4 Gb / II2G Ex ia IIIC T125 C Db IECEx+TEX Zone 2/21, not intrinsic safe II3G Ex n IIC T6/T4 Gc / II2D Ex tb IIIC T125 C Db Option 5: Cable length S Standard (7.6 m) m m N Option 6: dapter for cable protection system No With adapter for cable protection system K-RSCC - N - C RSCC accessories Rod end for RSC; 50 kg 100kg Rod end for RSC; 200 kg 1 t Rod end for RSC; 2 t 5 t 1-RSC/200KG/ZG 1-RSC/1T/ZG 1-RSC/5T/ZG Subject to modifications. ll product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure and predict with confidence HB 6 Hottinger Baldwin esstechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax info@hbm.com
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationLMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationMX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en
MX1609 Thermocouple amplifier Data Sheet Special features 16 inputs Connection of type K thermo couples to mini thermocouple sockets Measuring point identification via RFID Internal cold junction compensation
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationMX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en
MX1609 T Thermocouple amplifier Type T Data sheet Special features 16 inputs (electrically isolated) Thermocouple mini type T Measuring point identification Data rate up to 300 Hz 8 internal cold junction
More informationLMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInstallation instructions Cable transit device Roxtec RS ES Ex
General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationJUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationTECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT
RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationInstallation instructions Roxtec RS ES Ex
General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14
More informationEddy Current Probe System
CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationDS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO
Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More information3 Cleaning. 4 Technical data
EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years, Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationMaterial: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More information3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications
. Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationViper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge
The intrinsically safe compact scales combine leadingedge technology, user friendliness, and measurement certainty in rugged industrial design. APPROVED Ex ia 2 sensor technologies 5 weighing ranges 3
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationMaterial: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationTPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN
TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc
More informationSpeed sensor MiniCoder GEL 2471
Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More informationPanel-mounting Thermostats EM Series
Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationOrdering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.
Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationassociates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix
associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix Contents 1. Introduction 2. Selecting a model 2.1 Mounting 2.1.1 Field mounting 2.1.2
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationwww.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~
More informationW100L: Laser Sensor in Mini- Format
Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors
Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our
More informationW 9-2: A Versatile, Complete and Compact Series
suitable sensor can be selected from the W 9- series. Overview of the sensors: WT 9-, with adjustable background suppression, max. scanning distance 0 mm, WT 9-, energetic, max. scanning distance 0 mm,
More informationestat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C
Galltec ess- und Regeltechnik GmbH EA ensortechnik GmbH D-71145 Bondorf. Germany D-07987 ohlsdorf-teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0. Fax +49(0)3661-62704-20
More informationMK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)
MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) TECHNICAL DATA Measurement taken Position read sampling time (typical) Shock test DIN IEC68T2-27 Vibrations DIN
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationSurface-mounting thermostats ATH series
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 4, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 66 6003-0 Fax: +49 66 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationMeteor Product Catalogue
Meteor Product Catalogue Perfect results every time Sartorius is one of the leading suppliers of industrial weighing components worldwide. With more than 50 years experience in industrial in-process weighing
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationOnline data sheet GM32 IN-SITU GAS ANALYZERS
Online data sheet C D E F H I J K N O P Q S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information provided
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationEx td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread
I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem
More informationProduct Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide
Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide February 2007 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide
More informationMAGNETIC TAPE. Series MB. incremental scale. Key-Features:
MAGNETIC TAPE incremental scale Series MB Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...3 Installation Instruction...3 Digital Displays...4 Order Code...5 - Available
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More information1 Inductive proximity switches. 5 Connecting cables. Highlights: New:
Highlights: - All-metal housings - Miniature sizes - Long operating distances - Extreme environmental conditions - Analog outputs New: - All-metal devices for food industry and sea-water applications -
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationcdaq-itc Data Sheet cdaq Isolated Thermocouple Module Special Features Block Diagram B en
cdaq-itc cdaq Isolated Thermocouple Module Data Sheet Special Features - 16 channels of isolated thermocouple signal conditioning - Available for K-, J- or T-type thermocouples - Individual channel cold
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More informationKEL 183 Cable entry frames
KEL 183 Cable entry frames Description Type Order.No. Inserts KT PU KT 183 KT large The new version of the split cable entry frame KEL 183 enables the user to route cables and tubes with a diameter up
More informationAP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display
AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationCable installation guidelines
The Quality Connection Cable installation guidelines Business Unit Industrial Projects 2 Cable installation guidelines www.leoni-industrial-projects.com GENERAL Installation methods Many different methods
More informationPendant Light Fittings Series 6050
> Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket