Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Size: px
Start display at page:

Download "Centurion. Guided Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series."

Transcription

1 Sultan Sonar Manual Rev 1.0 A Higher Level of Performance Manual Centurion Guided Radar CGR Series For more information, please visit >

2 Table of Contents Contents Overview 3 Principle of Operation 3 Function 3 Primary Areas of Application 3 Wiring & Dimensions 4 Wiring Compartment 4 Flexible Probe 4 Housing 4 Rigid Probe 4 Probe C35 (Interface) 4 Safety Instructions 5 CGR2 Series Wiring in Hazardous Locations 5 Installation Guide 6 Placement Requirements 6 Connection Requirements - Metallic Vessels 7 Nozzle Mounting 7 Forces On The Probe 9 Powering The Unit For The First Time 10 Setup Procedure Setup Parameters Advanced Parameters Sensitivity Calibration 13 Troubleshooting - via Controller Keypad 14 False Echo Elimination 14 Unit is reading deeper than actual level 16 Unit is measuring deeper than the length of the cable 16 Part Numbering Flange Table 18 Specifications 19 Mounting 8 Minimum Clearance 8 2

3 Overview Principle of Operation Single Probe Microwave pulses are transmitted along a cable or probe to the product being measured. At the point where the wave meets the product surface it is reflected by the product. The unit automatically calculates the distance to the pulse reflection using time of flight & time expansion. The intensity of the reflection depends on the dielectric constant of the product. The instrument measures the time between emission and reception of the signal which is proportional to the distance. Dual Probe The unique patented HAWK Dual probe solution uses specially developed signal mapping techniques. The combination of HAWK s hardware and software give an accurate and consistent output for interfaces level measurement. Function Primary Areas of Application The HAWK range of Guided Radar products are ideal for the measurement of liquids, sludge, powders and granules to a range of 18m for level and interface. This technology is not affected by pressure, temperature, viscosity, vacuum, foam, dust, changes in dielectric constant or coating of the probe. Chemicals Petrochemicals Cement Building Aggregates Energy Food & Beverages Oil & Gas Pharmaceutical Pulp & Paper Wastewater Features Multiple Interface Measurement IECEx Ex d [ia] ia IIC T6 Gb Ga Up to 18m range (316L cable) Simple setup Auto-Calibration to any dielectric Adjustable Sensitivity Precise & continuous accuracy 2 wire loop 4-20mA, 2x 4-20mA, HART, Foundation Fieldbus, Profibus PA Protection class IP66 Measures extremely low dielectric (1.6) Programmable fail safe mode 3

4 Wiring & Dimensions Wiring Terminal Compartment Housing EMC GND GND + - EMC GND 87 Ex CABLE GLAND L1 = T.B.D. Flexible Probe Rigid Probe Probe C35 (Interface) (2.5") (1.5 ) 1 1/2" BSP or NPT mounting thread A B Cable Length (mm) F C D 4/8/16mm L= Determine by Application E G 4

5 Safety Instructions Safety Instructions For installation requirements for Hazardous Locations please refer to appropriate Safety Instruction document located at: CGR2 Series Wiring in Hazardous Locations mA current loop U = 14-28VDC See terminal compartment wiring Zone 1 EMC/Protective Ground Zone 1 or Zone 0 NOTE: (Ref Safety Instructions Sect 10a) Application of supply voltages above 28VDC will cause damage to the equipment. Voltages less than the U m will not invalidate the type of protection. 5

6 Installation Guide Placement Requirements Do NOT mount near infeed Do NOT mount over or adjacent to any obstacles 6

7 Installation Guide Connection Requirements - Metallic Vessels The unit requires a metallic flange or sheet connected to the unit thread. Avoid mounting adjacent to internal structures Probes should not contact metallic container walls or floors. Nozzle Metal flange Metal flange Interior Vessel Ceiling Min 100mm Multiple segmented connection If using thread multiple connection pieces for thread standard and size integration a metallic plate or flange of minimum recommended size should be at the lowest possible point of the mounting. Nozzle Mounting Avoid Narrow Nozzles Do NOT mount in long narrow nozzles Minimum measurable distance can be affected by narrow nozzles. Conduct Digitisation and/or increase Blanking to a safe minimum distance for example: double nozzle height + 25% safe distance High Level 7

8 Mounting Minimum Clearance Typically high dielectric materials (such as liquids) provide a good return signal. Low dielectric materials (such as plastics and powders) require higher levels of sensitivity to measure. Failure to adhere to mounting requirements can create a false signal reflection which will exhibit as high level lockups either from the distance of the interference of a multiple of the distance of the interference. Take into account the possibility of cable sway encroaching on the minimum clearance requirements. A B Clearances 8mm Cable 4mm Cable A. Minimum Nozzle Clearance 100mm (4 ) 100mm (4 ) A: Recommended Nozzle Clearance 300mm (12 ) 300mm (12 ) B. Minimum Wall Clearance 100mm (4 ) 100mm (4 ) B. Recommended Wall Clearance 500mm (20 ) 300mm (12 ) 8

9 Forces On The Probe Forces on the probe Tensile forces are heavily dependent on the viscosity and abrasive characteristics of the product in the vessel. Ensure tensile loading is appropriate for the selected cable (8mm or 4mm) as well as the silo cover and mounting structure. In critical cases it is better to select the larger flexible cable (8mm). Probe Type A04 (4mm flexible 20ºC) A08 (8mm flexible 20ºC) Tensile Force 5kN 19kN Lateral forces can exist due to movement and gradual flow of the product in the vessel, particularly with powder and granular materials. These forces can cause stress and strain on the probe, as well as the process fitting and mounting hardware. Ensure that lateral forces are minimised by following the installation guidelines and Placement Requirements. Probe Type B08 (8mm rigid 20ºC) C35 (Coaxial Probe 20ºC) Lateral Force 2kN 4kN 9

10 Powering The Unit For The First Time A. Confirm mounting is within recommended specifications. B. Check the selected unit matches the required application specifications. For Hazardous Locations see appropriate safety instructions available at C. Check the wiring is correct and all connections are secure. D. Apply power to the unit. When power is applied the unit will start its normal load sequence. The following messages will cycle on the display. Product Type Serial number Unit ID TDR Warming up The unit may take up to 30 seconds to warm up, and then it will perform a scan to locate the level. 10

11 Setup Procedure 1. Setup Parameters In this operational state you can use the buttons to navigate through and view unit diagnostics and other measurements. Setting Setup Application Parameters The Setup menu contains the basic parameters required to get the unit up and running. It is one of the three main menu options in the internal software. Main Menu Setup Advanced Autoset Setup Parameter Description Options Display Mode Select default Display mode Volume Level %Level Space Display Unit Adjust displayed measurement unit Centimeters Metres Feet Inches Low Level Set Low Level (4mA) distance Adjustable Hi Level Set High Level (20mA) distance Adjustable See Measured Span Reference Damping Set countdown for failsafe (seconds) Adjustable Fail Mode Set Analogue failsafe output 3.50mA 20.20mA LastKnown 4mA 20.00mA Measured Span Reference A A B C Blanking (non-measurable zone) Measurable Span (blanking to top of weight/end of cable) Weight (non measurable zone) B C 11

12 Setup Procedure 2. Advanced Parameters Setting Advanced Parameters The Advanced menu parameters are for adjusting primary Sensitivity, echo controls/filters, communications and output settings. Parameter Description Options Comms Adjust communication protocol settings. Device ID Baud Rate Digitize Sensitivity Blanking Cal Mount Perform auto-digitization of Sensitivity based on mounting and Dielectric of material touching the probe (see Setup Procedure A) Manual adjustment of Sensitivity. This value will also be automatically adjusted by other calibration routines. Sensitivity is the primary adjustment for the units ability to detect media Blanking is a non-measurable zone. This can be increased to Blank out high level false echoes caused by mounting Performs a digital mapping routine of a user selected span. Used when there is signal interference at high level or mounting. Use Digit Bias to adjust bias (cal sensitivity) of mapping range Execute Disable Cancel Adjustable Cal Start Cal End Analogue Adjust and tune 4-20mA settings mA tuning 20mA tuning Park 4mA Park 8mA Park 12mA Factry Reset Restore unit to factory defaults Yes No Device Info Display device information Lock Code Adjust the peak Sensitivity cap. This value will be automatically adjusted by other calibration routines Disable Enable 12

13 Setup Procedure 3. Sensitivity Calibration Procedure A: Running Digitize while material is touching the probe Procedure B: Using dielectric pre-sets Procedure C: Manual Sensitivity Adjustment Procedure A: Running Digitize while material is touching the probe This procedure uses automatic procedure for sensitivity adjustment & mapping to calibrate the system based on the dielectric of the material touching the probe element and the mounting conditions. This is the recommended calibration procedure for fastest and most accurate unit setup. Digitize is located in the Advanced menu. Procedure B: Manual Sensitivity Adjustment This procedure is an advanced method for calibrating the sensitivity of the system. This involves manually adjusting the sensitivity until the unit is measuring the length of the sensing element or to the depth of material touching the sensing element. The Sensitivity parameter is located in Adv Setup You can press CAL to fire test pulses. After each pulse the unit will return the signal strength and distance (depth) of the echo. You should aim for a signal strength of 2-2.5V. This may not be achievable with low dielectric materials. 13

14 Troubleshooting - via Controller Keypad False Echo Elimination Before conducting these steps it is recommended to perform Setup Procedure: Sensitivity Adjustment Procedure A and ensure mounting requirements are met. Some of the procedures below are performed automatically by the routine. 1a. Sourcing false echo distance (high level lock) While the unit is operating and locked onto a false echo you can scroll through diagnostics using the arrow keys on the keypad. The top line of the display will change but the bottom line will continue to indicate the standard display mode measurement (such as Space or Material%) E: % Depth Material% Press the UP arrow until the E: diagnostic is displayed. This indicates the depth of the false reading. 1b. Identify signal size of false echo S: 0.74V 110.7% Press the UP arrow again until the S: diagnostic is displayed on the top line. This indicates the signal size of the echo the unit is measuring (this will be between 0.4V and 2.5V). 2. Eliminating false echo There are three primary methods of echo elimination Cal Mount: If you cannot perform Sensitivity Adjustment Procedure A you can manually perform part of this procedure via Cal Mount in Adv Setup. You will be prompted to enter the Cal Start and Cal End distance. You should enter a distance safely closer and deeper than the false echo. You should not enter a value longer than the probe. If the material in the vessel is touching the probe ensure the Cal Mount does not pass this depth. The parameter CalSnstvty in Adv Setup can be used to increase or decrease the uniform sensitivity of the Cal Mount span. After the Cal Mount is complete press RUN several times to return to unit operation. The unit will then begin to scan deeper down the length of the cable to find the next valid echo. 14

15 Troubleshooting - via Controller Keypad 2-2. Reduce Sensitivity: Enter the Adv Setup menu and scroll until you see Sensitivity parameter. Press CAL to edit. Use the DOWN arrow to reduce this value. Pressing CAL will fire a test pulse and return the diagnostic data of the Signal size and E: distance. Fire several test pulses for a good sample size. Reduce this value until the unit is no longer displaying the false echo while firing test pulses. Press RUN to save and RUN again to return the unit to operating mode. The unit will then begin to scan deeper down the length of the cable to find the next valid echo.. 100% Fig 1 Sensitivity Range 50% 90% 0% False Echoes Correct Level Distance In Fig 1 you can see at 90% Sensitivity both false echoes and the correct level are considered valid targets by the unit. At 50% Sensitivity the only echo the unit will see is the correct level 3. Blanking & Span adjustment If the previous steps are unable to solve a high level lock up there will be a significant signal interference. Visually examine within the vessel for any objects near or touching the sensing element. Extend Blanking beyond the depth of the false echo and adjust High level so it is not within the blanked distance. Perform a 15 second power cycle, the unit will re-scan for the closest signal which beyond the Blanking distance. Attempt to perform Setup Procedure A, B or C if the unit does not locate the correct distance with the false echoes blanked out. 15

16 Troubleshooting - via Controller Keypad Unit is reading deeper than actual level This may occur in low dielectric applications where the cable weight returns a stronger echo than the measured material. If you have used any other parameters such as Cal Mount perform a Probe Reset. Increase Sensitivity: Enter the Adv Setup menu and scroll until you see Sensitivity parameter. Press CAL to edit. Use the UP arrow to increase this value. Pressing CAL will fire a test pulse and return the diagnostic data of the Signal size and E: distance. Fire several test pulses for a good sample size. Increase this value until the unit is returning a strong (2-2.5V) Signal size from the false echo. Press RUN to save and RUN again to return the unit to operating mode. Perform a 15 second power cycle - when the unit re-starts it will begin a new scan over the entire probe to find the closest echo which passes the Threshold value. Unit is measuring deeper than the length of the cable Press CAL and enter Unlock Code 196 and press CAL. Scroll through the main menus to locate FactoryTDR menu. Press CAL to enter this menu. Scroll down to locate the EmptDist parameter. This should be the length of the cable by factory default. If not, reduce this value to the correct length with a small additional margin (+250mm/12 ). DO NOT ADJUST ANY OTHER PARAMETERS IN THIS MENU. Perform a 15 second power cycle - when the unit re-starts it will begin a new scan over the entire probe to find the closest echo which passes the Threshold value. 16

17 Part Numbering Model CGR2 CGR4 2 wire 4 wire Communication X 4-20mA analog H 4-20mA with HART A Profibus PA F Foundation Fieldbus Y 2x 4-20mA with HART on channel 1 Housing 1 Aluminium 2 316L Gland Entry 1 1/2 NPT Cable gland entry 2 3/4 NPT Cable gland entry Probe Type A04 4mm flexible cable A08 8mm flexible cable B04 4mm rigid probe B08 8mm rigid probe B16 16mm rigid probe 3 M20 x 1.5 Cable gland entry 4 M25 x 1.5 Cable gland entry C35 Coaxial model 1 D01 Coaxial model 2 E01 Coaxial model 3 Probe variant / materials S 316L H HC-276 T PTFE coated 316L rod Mounting TN07 3/4 NPT Thread (316L) TB07 3/4 BSP Thread (316L) TN10 1 NPT Thread (316L) FLXX 1 Flange Mount TB10 TN15 TB15 1 BSP Thread (316L) 1.5 NPT Thread (316L) 1.5 BSP Thread (316L) Process O-ring seal S Standard seal V Viton E EPDM K B Kalrez NBR Process Temperature for probe 1 80C 4 250C 2 150C 7 450C Process Pressure 1 5 bar 3 20 bar 2 10 bar 4 40 bar bar bar CGR2 X 2 2 B08 S TN15 S 1 1 1D See flange selection table. Flange is selected as separate line item Approval Standard XX Not Required 1D IECEx Ex d [ia] ia IIC T6 Gb Ga Probe Length Probe length in cm (max 1800) 17

18 Part Numbering Flange Table FLA-FA2-SS FLA-FD2-SS FLA-FA3-SS FLA-FD3-SS FLA-FA4-SS FLA-FD4-SS FLA-EA2-SS FLA-ED2-SS FLA-EA3-SS FLA-ED3-SS FLA-EA4-SS FLA-ED4-SS FLA-HA2-SS FLA-HA3-SS FLA-HA4-SS FLA-C2-SS FLA-C3-SS 2 ASME/ANSI 150lb Flange (316L) DN50 pn16 Flange (316L) 3 ASME/ANSI 150lb Flange (316L) DN80 pn16 Flange (316L) 4 ASME/ANSI 150lb Flange (316L) DN100 pn16 Flange (316L) 2 ASME/ANSI 300lb Flange (316L) DN50 pn40 Flange (316L) 3 ASME/ANSI 300lb Flange (316L) DN80 pn40 Flange (316L) 4 ASME/ANSI 300lb Flange (316L) DN100 pn40 Flange (316L) 2 ASME/ANSI 600lb Flange (316L) 3 ASME/ANSI 600lb Flange (316L) 4 ASME/ANSI 600lb Flange (316L) 2 clamp (hygenic) 3 clamp (hygenic) 18

19 Specifications Operating Voltage 14 28VDC (residual ripple no greater than 100mV) HART 250 Ohms Power Consumption 24VDC Analog Output 0 Ohm 250 Ohms 500 Ohms Load (Ohms) Supply Voltage (VDC) Communications* 4-20mA, 2x 4-20mA, GosHawk, HART, Foundation Fieldbus, Profibus PA. Maximum Range 18m Dielectric Range 1.6 Resolution Distance: 0.65mm Analog: 0.5uA Display: 1.0mm Accuracy +/- 3mm Sum of non linearity, non repeatability, hysteresis Analog +/- 0.02% Repeatability +/- 2mm *Specifications model dependent. Consult part number listing. 19

20 Specifications Memory Non-Volatile (No backup battery required) >10 years data retention Measurement Range of Electronics Min. 150mm Max. 18m Operating Temperature (Electronics) -20ºC to +80ºC (-28 to +176ºF) Process Pressure* -1 to 450 BAR Process Temperature* -30ºC to +450ºC (-35ºF to +842ºF) Display 4 line graphic display (128 x 64) Approvals* IECEx Ex d [ia] ia IIC T6 Gb Ga Process Pressure (Bar) Standard Unit Process Temperature (Deg C) Probe Physical Load Max tensile load on 8mm cable: 4 tonnes at 23ºC 3 tonnes at 80ºC Max lateral force on C35 probe: 4 kn *Specifications model dependent. Consult part number listing All company or product names are registered trademarks or trademarks of their respective owners. Hawk Measurement Systems Hawk Measurement (Head Office) 96 Glenn Street Maurice Court Lawrence, MA 01843, USA Nunawading VIC 3131, AUSTRALIA Phone: HAWKLEVEL ( ) Phone: Phone: Fax: Fax: info@hawk.com.au info@hawkmeasure.com Additional product warranty and application guarantees upon request. Technical data subject to change without notice. DOC-CGR-MAN

2291 Guided Wave Radar Level Transmitter

2291 Guided Wave Radar Level Transmitter 2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,

More information

Guided Wave Radar Level Meter

Guided Wave Radar Level Meter Guided Wave Radar Level Meter Guided Wave Radar Level Meter Instruction 1. Product Description 1.1 principle of measurement Guided Wave Radar is the measuring instruments that based on the time travel

More information

Liquid Level Sensor Type AKS 4100U

Liquid Level Sensor Type AKS 4100U Data sheet Liquid Level Sensor Type U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range of refrigeration applications. The

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Capacitance Level Measurement Electronic insert FEC 12

Capacitance Level Measurement Electronic insert FEC 12 Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

Liquid Level Sensor AKS 4100U

Liquid Level Sensor AKS 4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U U - Cable Version U - Coaxial Version The U liquid level sensor is designed specifically to measure liquid levels in a wide range

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal Operating and installation manual Programmable differential pressure transmitter for pressure or flow measurement and control. MF-PFT Instruction : Mi-202gb_060907 NOTE! Read the entire instruction carefully

More information

Type AKS 4100/4100U Coaxial D14 version

Type AKS 4100/4100U Coaxial D14 version Instruction Type /4100U Coaxial D14 version Available lengths:, 500 mm, 800 mm, 1000 mm, 1200 mm, 1500 mm, 1700 mm, 2200 mm M84H0030_1 U, 19.2 in. U, 30 in. U, 45 in. U, 55 in. U, 65 in. U, 85 in. Push

More information

Liquid Level Sensor Type AKS 4100/4100U

Liquid Level Sensor Type AKS 4100/4100U Data sheet Liquid Level Sensor Type /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sensor is designed specifically measure liquid levels in a wide range of refrigeration

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

OPTIFLEX 2200 C/F Technical Datasheet

OPTIFLEX 2200 C/F Technical Datasheet OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions

More information

Liquid Level Sensor AKS 4100U

Liquid Level Sensor AKS 4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sensor U www.danfoss.us Liquid Level Sensor, U Contents Page Introduction...3 Features...3 Product concept...3 Cable Version...................................................................................3

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

MAGNETOSTRICTIVE LEVEL TRANSMITTER

MAGNETOSTRICTIVE LEVEL TRANSMITTER MAGNETOSTRICTIVE EVE TRANSMITTER http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 EG series Magnetostrictive evel Transmitter is built based on the principle of magnetic

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

FIELD MOUNTED RATE TOTALISER MODEL 202D

FIELD MOUNTED RATE TOTALISER MODEL 202D FIELD MOUNTED RATE TOTALISER MODEL 202D 16 June 2003 Introduction 1 1. INTRODUCTION The Model 202Di Rate Totaliser is a microprocessor based instrument which accepts a frequency or pulse input from

More information

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Short Manual. ZX2 Short Manual.doc Page 1 of 12 Short Manual ZX2 Short Manual.doc Page 1 of 12 1 Safety precautions and correct use Please refer to the full ZX2 user manual for the detailed explanations of the safety precautions and the correct use.

More information

Guided Wave Radar Level Meter. manual of operation

Guided Wave Radar Level Meter. manual of operation Guided Wave Radar Level Meter manual of operation Display/Adjustment Adjustments can be done with four buttons on theview point. Optional menu languages are available. View point is only used for display

More information

Guided Radar (TDR) Level Transmitter for storage and process applications

Guided Radar (TDR) Level Transmitter for storage and process applications OPTIFLEX 2200 C/F Technical Datasheet Guided Radar (TDR) Level Transmitter for storage and process applications Modular design of housing and sensor ensures suitability for a variety of mounting positions

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

MSP422 Analogue Liquid Level Transmitter Software version 1.2A and onwards

MSP422 Analogue Liquid Level Transmitter Software version 1.2A and onwards Installation, Operation & maintenance manual IP2013, Rev. AA May 2007 Level MSP422 Analogue Liquid Level Transmitter Software version 1.2A and onwards MSP422 Programming Menu IP2013/PM www.mobrey.com IMPORTANT

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

IMP Lite INSTRUCTION MANUAL

IMP Lite INSTRUCTION MANUAL IMP Lite INSTRUCTION MANUAL IMP Lite (FIRST EDITION REVISION 2) June 2017 Part Number M-082-0-001-2P COPYRIGHT Pulsar Process Measurement Limited, 2005-17. All rights reserved. No part of this publication

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

EchoSpan Two-Wire Ultrasonic Level Transmitter Model LU81/83/84 Owner s Manual

EchoSpan Two-Wire Ultrasonic Level Transmitter Model LU81/83/84 Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows: www.flowline.com On-line Warranty Registration

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Operating Instructions 09/2013

Operating Instructions 09/2013 Guided Wave Radar SITRANS LG260 4 20 ma/hart two-wire Operating Instructions 09/2013 2 SITRANS LG260 - Operating Instructions PBD-51041057 Contents 1 About this document 1.1 Function... 5 1.2 Target group...

More information

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1

More information

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL MODEL NUMBER: HCM991-0-0-GB-XX FlexiScan SPECIFICATIONS Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL Working Environment... Security... Input Voltage... The Impro FlexiScan is designed to work

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

IMP+ INSTRUCTION MANUAL

IMP+ INSTRUCTION MANUAL IMP+ INSTRUCTION MANUAL IMP+ (FOURTH EDITION REV 2) June 2017 Part Number M-080-0-004-2P COPYRIGHT Pulsar Process Measurement Limited, 2005-17. All rights reserved. No part of this publication may be reproduced,

More information

MT5000 MT5000. Installation & Operation Manual. Guided Wave Radar Level Transmitter. For the latest version of this manual, visit ktekcorp.com.

MT5000 MT5000. Installation & Operation Manual. Guided Wave Radar Level Transmitter. For the latest version of this manual, visit ktekcorp.com. Installation & Operation Manual MT5000 For the latest version of this manual, visit ktekcorp.com. MT5000-0200-1 Rev g (2-2013) DCN0528 TABLE OF CONTENTS 1.0 Introduction... 3 2.0 Overview... 4 2.1 Storage

More information

OPTIFLEX 1100 C Handbook

OPTIFLEX 1100 C Handbook OPTIFLEX 1100 C Handbook Guided Radar (TDR) Level Meter Continuous level measurement of liquids and solids KROHNE : IMPRINT ::::::::::::::::::::::::::::::::::::::: All rights reserved. It is prohibited

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Centurion. Guided Wave Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0 TDR/GWR.

Centurion. Guided Wave Radar. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0 TDR/GWR. Sultan Sonar Manual Rev 1.0 A Higher Level of Performance Manual Centurion Guided Wave Radar TDR/GWR For more information, please visit > www.hawkmeasure.com Table of Contents Contents Overview 3 Principle

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

Rosemount 1151 Smart Pressure Transmitter

Rosemount 1151 Smart Pressure Transmitter Rosemount 1151 Smart Pressure Transmitter Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Connect the Wiring and Power Up Step 4: Set Switches Step 5: Configuration Step 6:

More information

Registers type ILR7XX and ILR7XXT

Registers type ILR7XX and ILR7XXT Badger Meter Europa GmbH Registers type ILR7XX and ILR7XXT INSTALLATION AND OPERATION MANUAL May 2018 Contents Page 1. Basic safety recommendations... 1 2. Register operation... 3 2.1. Normal operation...

More information

INSTALLATION & USER GUIDE

INSTALLATION & USER GUIDE INSTALLATION & USER GUIDE Digidim 458 8-Channel Dimmer STEP 1 Assemble Dimmer Unit STEP 2 Mount Dimmer Chassis STEP 3 Electrical Installation STEP 4 Attach Module and Make Connections STEP 5 Replace Cover

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs Q. What are the channel assignments for On Air Test Mode? A. The assigned GOES test channels are as follows: GOES West 300 Baud:

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

Operating Instructions 09/2013

Operating Instructions 09/2013 Guided Wave Radar SITRANS LG250 4 20 ma/hart - two-wire Operating Instructions 09/2013 2 SITRANS LG250 - Operating Instructions PBD-51041047 Contents 1 About this document 1.1 Function... 5 1.2 Target

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

Operating Instructions

Operating Instructions Operating Instructions LEVEL TRANSMITTER 8188 4 20 ma/hart two-wire Rod and cable probe 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbols used... 4 2 For your

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview. Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

DSIM-GI Installation Guide Revision P

DSIM-GI Installation Guide Revision P Installation Guide Revision P 1. Quick Start Instructions for Single Pilot AGC Operatation 1. With the ADU jumper in Auto position, turn ADU pot to MIN amplifier output level. Then place the ADU jumper

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

FLOMAT Electromagnetic Insertion Flowmeter

FLOMAT Electromagnetic Insertion Flowmeter LOMAT Electromagnetic Insertion lowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction or use in large diameter pipes or open channels as an

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Liquid Level Sensor AKS 4100/4100U

Liquid Level Sensor AKS 4100/4100U MAKING MODERN LIVING POSSIBLE Technical brochure Liquid Level Sens /4100U /4100U - Cable Version /4100U - Coaxial Version The /4100U liquid level sens is designed specifically measure liquid levels in

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN ULTRA-TRAC APL A C O U S T I C P I P E L O C A T O R INSTRUCTION MANUAL Read and understand instructions before use. Patented MADE IN USA 851 Transport Drive Valparaiso, IN 46383-8432 Phone: 888 4SENSIT

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI Level Measurement Siemens AG 2013 Overview Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous liquids, temperatures to 170 C (338 F), corrosive and aggressive materials

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter 3 YEAR SENSOR WARRANTY 5.4 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. General MJK Oxix s are designed

More information

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. Indicators/operating means Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams

More information

T775U Series 2000 Electronic Stand-Alone Controller

T775U Series 2000 Electronic Stand-Alone Controller T775U Series 2000 Electronic Stand-Alone Controller INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The T775 electronic stand-alone controllers are the next generation of universal controls capable of remote

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

The measurements are stored in non-volatile memory, which retains data even when the power down.

The measurements are stored in non-volatile memory, which retains data even when the power down. Data Sheet: DSTAR.545.R1.ENG www.aep.it FAST Professional Handheld Indicator Dynamicstar is an professional indicator, ergonomic, extremely versatile and simple to use for measures FORCE, WEIGHT, PRESSURE,

More information

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416 COMPANY MX 9000 Process Monitor Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:MXMAN082416 1 Table of Contents Unpacking...3 Quick Guide...3 Connect to Sensor...3

More information