Barbican Concert Hall Sound System Spec

Size: px
Start display at page:

Download "Barbican Concert Hall Sound System Spec"

Transcription

1 PA, FOH and Monitor System Main PA The system is predominantly Meyer Sound and is driven by two Meyer Sound Galileo 616 digital processors, which provide the time alignment and EQ for each part of the system including ancillary loudspeakers, if required. Flown arrays Main L/R: 1 x M3D - SUB 1 x MEYER MILO 60 4 x MEYER MILO 90 2 x MEYER MILO 120 Centre: 8 x MEYER M ELODIE Out fill L/R: 2 x RENKUS HEINZ TR 12-1 Stage PA 4 x MEYER HP700 Sub 4 x MEYER UPJ out fill 4 x MEYER M1D front fill Foldback Upon request up to 4 mixes from FOH UPJ (flown on the back of the centre cluster) 8x d&b MAX15 monitor wedges Front of House Choice of FOH sound consoles: DiGiCo SD7 with Waves option fitted (hirer must provide own Waves servers and licences) DiGiCo SD9 with Optics fitted DiGiCo I/O Options available depending on requirements: o 1x SD Rack 56 Inputs / 24 Outputs o 1x SD Mini-Rack 24 Inputs / 8 Outputs o 1x D-Rack (with Optics) 32 Inputs / 16 Outputs o 1x SD Mini-Rack 16 Inputs / 16 Outputs this rack is permanently installed providing input to the PA system processors Midas H ch (36 mono/ 4 stereo) + (16ch extension wing is available on request). Total: 52 mono Input Channels. Yamaha M7CL-32 (32 mono/ 4 stereo) Yamaha LS9-16 In-house help and support is provided when using our consoles.

2 The FOH rack consists of: 2 x Drawmer DS404 Gate total 8ch 3 x BSS DPR-404 Compressor total 12ch Klark Teknik DN3600, programmable Graphic EQ (usually over Left & Right) Klark Teknik DN3601, slave unit for DN3600 (usually over Subs + spare) Klark Teknik DN370, 2x 30 Band Graphic EQ (usually over Centre & Front Fills) Tascam DA20 mk 2 CD Player The effects rack consists of: Lexicon PCM 91 Digital Reverb TC M-3000 Multiple FX processor Yamaha SPX 990 Multiple FX processor Roland D2 Echo The EQ rack consists of: 3 x Klark Teknik DN370, 2x 30 Band Graphic EQ Available on request: Avalon 737 Typical Monitor system subject to availability and requires quoting 1x Midas Heritage 3000/SD7/PM5D 12x channels KT DN360 EQ 2x channels gates 2x channels compressors 1x REV500 or equiv 12x channels power and control for: 14x actively powered 15 inch with horn wedge monitors All equipment details are subject to change. Tie Lines - Stage to FOH Mixing Position Audio FOH mix position to stage has 72 lines + 12 returns all on XLR tails FOH, with monitor desk splits (also on XLR tails situated SL) and 12 way floating XLR stage boxes onstage. There are dedicated Optical Con patch points at FOH, on stage (SR and SL), and various other locations around the venue for linking into the DiGiCo fibre network. An Optical Con to HMA optical connector convertor box is also available upon request. Data Extensive Cat6 patching capability around the venue including: 4 points at FOH and 2 at SR and SL. FOH, SR and SL all have the following tie lines to the projection room: 6x BNC (HD SDI / MADI) 8x Multimode fibre on ST connectors 4x Singlemode fibre on LC connectors

3 Communications 2 Channel wired RTS comms are provided Telex Radio comms system comprises of a Telex BTR700 Base Station, and 4x TR700 Wireless Beltpacks. Radio Frequencies Concert Hall Channels used for Shure UHF-R radio microphone system in the Concert Hall and Telex Wireless Comms Packs. ANY INCOMING EQUIPMENT MUST BE TUNED TO THESE RADIOMIC FREQUENCIES UNLESS A SPECIFIC LICENSE IS OBTAINED FROM JFMG 1 Shure UHF-R Ch 38 2 Shure UHF-R Ch 39 3 Shure UHF-R Ch 39 4 Shure UHF-R Ch 40 5 Shure UHF-R Ch 41 6 Shure UHF-R Ch 41 7 Shure UHF-R Ch 41 8 Shure UHF-R Ch 41 9 Shure UHF-R Ch Shure UHF-R Ch 43 The table below shows frequencies permanently in use for our Telex Wireless Comms system, and incoming equipment must avoid these frequencies. Base Telex BTR Ch 27 1 Telex TR Ch 41 2 Telex TR Ch 41 3 Telex TR Ch 41 4 Telex TR Ch 41 Power Both sides of the stage have the following on Ceeform: 1x 125A 3, 1x 63A 3 and 2x 16A 1, as well as 1x 110VAC 16A all available for Sound, AV and Backline power.

4 Microphone List Brand Model Misc Quantity AKG C414B-ULS 4 C414B-XLS 2 C451 1 C460 Cardioid C61 head 9 C460 Omni C62 head 2 C460 Hyper C63 head 2 C480 3 C5 2 C535 3 C747 6 D12E 1 AMT M40 1 AUDIO-TECHNICA AT857QM 4 BEYERDYNAMIC M201 N 1 M201 TG 2 M88 9 BSS DI Box AR COLES 4104-B 1 CROWN PCC160 4 PZM-6LPB 1 DPA 4060 Black Black Violin/Viola Cello 1 ELECTROVOICE PL80 1 RE16 3 RE20 1 NEUMANN KM184 8 KMS PHANTOM POWER 4-pin Mini XLR 9 ADAPTORS SENNHEISER MD421 7 MD918 U 4 SCHOEPS CMC 5 MK21 head 2 SHURE BETA 52A 1 BETA 57A 8 BETA 58A 5 BETA 87A 6 BETA 91 2 BETA 98 5 BETA Pre-Amp 1 MICROFLEX Pre- 5 Amp SM57 8 SM58 12

5 SM58 (s) 2 SM87 1 SM98 5 UR-1 10 UR-2 58 head 10 SONY C48 2 ECM 30 1 ECM 50 1 ECM 55 2 ECM 77 1 All microphones are provided with stands and correct clips. All equipment details are subject to change. DJ Kit 2x Pioneer CDJ 1000 MK3 in KamKase flight case 2x Technics SL-1200 MK2 1x Pioneer DJM 500 All equipment details are subject to change.

6

7 ACOUSTIC PANEL SETTINGS SETTINGS There are six programmed acoustic panel settings using the four panels in a closed mode at different heights and angles: 1 MOD MOD 3 * to be used for LSO concerts For full symphony orchestras with / without choir 2 FULL ORCHESTRAL to be used for BBC SO concerts 3 CHAMBER STEEP For chamber orchestras, small baroque opera set-ups and recitals with balcony on sale. 4 CHAMBER SHALLOW * For chamber orchestras, small baroque opera set-ups and recitals with balcony offsale. 5 ORCHESTRAL LX For classical concerts requiring use of LX bars 1, 3 and 6 6 OPEN ALL REFLECTORS VERTICAL For contemporary concerts using all lighting bars * Please note that lighting from FOH Bridge 1 is restricted when using the Chamber Shallow and the MOD MOD 3 setting. ADDITIONAL INFORMATION It takes c30 mins to change from one setting to another with no artists / external crew on stage. Panel changeovers require two Barbican staff to operate and all technical and backstage crew have been trained in operation. Event notes should detail the name of the panel setting and time allowed within the schedule for panel changeovers e.g. there may be a morning LSO rehearsal (LSO setting) followed by an afternoon session and evening concert with open balcony by the Gabrieli Consort (Chamber Steep setting) We do not propose to discuss panel settings with individual ensembles in advance we would simply like to provide the most appropriate acoustical setting for the performance in terms of ensemble and audiences sizes.

National Theater_sound

National Theater_sound 03- 3 : Equipment 3 Control Room Item Brand/ Type Amount Note Mixer STUDER VISTA- 8 50 Channel 4 Line Channel 8 Master mono 8 Group stereo 0 Aux mono 4 Aux Stereo CD-RW TASCAM CD-RW000 For recording use

More information

Sound Equipment Sound Control Room

Sound Equipment Sound Control Room Sound Equipment Sound Control Room National Theater & Concert Hall _ Theater _sound&video technical information Mixer STUDER VISTA- 8 50 Channel 24 Line Channel 8 Master mono 8 Group stereo 0 Aux mono

More information

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing) Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing) Technical requirements 1 Stages minimum stage dimensions 10x10 (other dimensions

More information

Hard Rock Cafe Times Square Sound System Advance Sheet

Hard Rock Cafe Times Square Sound System Advance Sheet Hard Rock Cafe 1501 Broadway New York, NY 10036 (212) 343-3355 t (212) 938-1901 f Hard Rock Cafe Times Square Sound System Advance Sheet FOH PA: Speakers: 8 - Clair Brothers R3T (4 ea. side) flown on sides

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 02/06/2015 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

US 2015/16 TECH RIDER

US 2015/16 TECH RIDER 1 US 2015/16 TECH RIDER 2 AFRO-CUBAN ALL STARS RIDER. NOTE: This document, whose content must be strictly followed by the PROMOTER, must be attached as an addendum to the contract and signed in all of

More information

Dr JOHN GALLAGHER CONCERT CHAMBER

Dr JOHN GALLAGHER CONCERT CHAMBER 1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium

More information

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee Audio Equipment (Audio Equipment Continued...) Console Cable MIDAS VERONA ( channels)

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 03/07/2015 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

UNIVERSITY CONCERT HALL. Technical Specification

UNIVERSITY CONCERT HALL. Technical Specification UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing

More information

Mics, DIs, Stands, and Cables

Mics, DIs, Stands, and Cables TALKING STICK RESORT Audio Main PA System is zoned as Left and Right with Aux fed Subs. Front fills, under balcony fills, VIP fills, and hearing assist are all sent from separate matrixes off of the console.

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 14/08/2018 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet - 2018 Rooming List 03 DBL: Verônica Fernandes, Masako Tanaka Priscilla Azevedo, Marina Spoladore Carlos Fausto Brito, Rafael Duarte 02 SGL: Claudio

More information

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m) General info Public Entrance Atlantisplein 1 Loading dock Arcadia Left side of the building. Ramp available. *elevator available (1,4m x 3,3m) Zip-code 1093 NE City Amsterdam Telephone Front desk 020-7606780

More information

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List Ex-Hire Used Equipment Price List This List Dated: 27/02/2019 Subject to SSE Audio Group's Standard Terms & Conditions of Sale. Prices exclude VAT, delivery and collection. Errors & Omissions Excepted.

More information

SOUND TECH RIDER FIDO

SOUND TECH RIDER FIDO SOUND TECH RIDER FIDO Tech advancing conctact for FIDO is mr. dave muscheidt 0041788745005/muscheid@tiscali.ch 1. SOUND IN GENERAL After receiving this rider please ask your tech coordinator/production

More information

BITUSA 2019 General DRESSING ROOMS

BITUSA 2019 General DRESSING ROOMS Attention Marketing and Promotions Parties agree to make appropriate disclosure that artist is a celebrity impersonator and not the actual celebrity. The word "Tribute to" must be in all advertising. In

More information

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam technical rider version August 2015 People s Place Stadhouderskade 5-6 1054 ES Amsterdam Technical Rider 2 Index Index... 2 1. Audio... 3 1.1 PA System Stage Area (Main setup)... 3 1.2 PA System Stage

More information

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK If the Client does not have any of these items or facilities available or cannot provide them precisely as specified, the Production Company

More information

Section A: Front of House (FOH) Public Address (PA) Speaker System

Section A: Front of House (FOH) Public Address (PA) Speaker System Annexure A TECHNICAL SPECIFICATIONS This annexure is a detailed list of the staffing and equipment that must be provided and professionally operated by the Sound Engineering Service Provider at every concert

More information

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m Main House Technical Specification Get In Access for loading and unloading is via St Stephen s goods yard into the Hull Truck loading bay. Flat access at Stage Level for HGV s, backing directly onto main

More information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface

More information

Matt Dann Cultural Centre

Matt Dann Cultural Centre Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:

More information

TECHNICAL SPECIFICATIONS LEPERCQ

TECHNICAL SPECIFICATIONS LEPERCQ TECHNICAL SPECIFICATIONS LEPERCQ Version: January 2018 Brooklyn Academy of Music Revised: January 31, 2018 30 Lafayette Ave Revised By: R. Gastelum Brooklyn NY, 11217 Phone: 718 636 4146 Fax: 718 857 166

More information

Main Stage Technical Specs - Hall #2

Main Stage Technical Specs - Hall #2 Main Stage Technical Specs - Hall #2 Proscenium: - Height:...20' (06.10m) - Width:...31' 10"(09.70m) Apron: - Depth:...4' (01.22m) - Width:...45' 6" (13.87m) - Height:...3' 7" (01.09m) Stage: - Maximum

More information

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Tickets will be sold through our ABC account and all tickets are scannable on entry. VENUE INFORMATION TICKETING We have NO daytime walk-in box office. Online: www.electricballroom.co.uk Tickets will be sold through our ABC account and all tickets are scannable on entry. The venue requires

More information

HORACE X PERFORMANCE REQUIREMENTS (Technical)

HORACE X PERFORMANCE REQUIREMENTS (Technical) 1 HORACE X PERFORMANCE REQUIREMENTS (Technical) PA System: Minimum Requirement: Horace X need a professional, clean, full-range P.A. Sound System designed for live Rock groups, with a suitable power rating

More information

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 (Revised October 2018) Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 PAC STAFF Director of Operations Andy Binder Production Manager Tom Kostusiak

More information

General & Technical Specifications:

General & Technical Specifications: General & Technical Specifications: Physical Address: Seating Capacity Proscenium Opening: Stage Depth: Stage Width: Stage Height: Orchestra Pit: Stage Floor: Crossover: Loading Door: East side of San

More information

Dinkelspiel Auditorium - Technical Specifications

Dinkelspiel Auditorium - Technical Specifications Mailing Address Stanford Music Department 541 Lasuen Mall Stanford, CA 94305 Venue Address 471 Lagunita Dr Stanford, CA 94305 Production Coordinator Kevin Sweetser ksweets@stanford.edu House Specifications

More information

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018! LOCATION ADDRESS GPS A38 Ship - Budapest Henryk Slawik lower quay (Petőfi Bridge Buda side) H-1117 Budapest lat=47.476528, lon=19.06292 PHONE 0036 1 464 39 40 FAX 0036 1 464 39 45 WEBSITE E-MAIL PROHIBITED

More information

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice! YAAM Berlin Venue Specifications & Technical Rider Effective April 2018 Availability, errors and specifications subject to change without notice! Venue Address: An der Schillingbrücke 3 10243 Berlin Germany

More information

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info VENUE SPECS 2017 Musik & Frieden Channel Music GmbH Falckensteinstr. 48 10997 Berlin booking@musikundfrieden.de +49 (0)30-78 09 98 27 2 Floor Plan 3 Black Room 8 Blue Room 12 Venue Info 13 Parking www.musikundfrieden.de

More information

111 North 5 th Street Minneapolis, MN 55403

111 North 5 th Street Minneapolis, MN 55403 - 1-111 North 5 th Street Minneapolis, MN 55403 Venue Address Mailing Address: 111 North 5 th Street 510 1 st Avenue North Minneapolis, MN 55403 Suite 402 Minneapolis, MN 55403 Website www.millcitynights.com

More information

Bloomington Center for the Performing Arts. Technical Specifications

Bloomington Center for the Performing Arts. Technical Specifications Bloomington Center for the Performing Arts Technical Specifications JOEL AALBERTS Performing Arts Manager (309) 434-2764 DAVID YOUNG Facility Manager (309) 434-2761 RODNEY W. STICKROD Technical Manager

More information

Information for Incoming Companies

Information for Incoming Companies Information for Incoming Companies The Stables Theatre Stockwell Lane Wavendon Milton Keynes MK17 8LU General The Stables is an internationally renowned music organisation with a vision to engage the widest

More information

Complete guide Compiled January 2014

Complete guide Compiled January 2014 Complete guide Compiled January 2014 Over View The Asylum Bar and Venue is a purpose built live music venue situated within half a mile of Birmingham City Centre, just a two minute walk from Snow Hill

More information

Technical Specifications

Technical Specifications FOLLY THEATER 300 W. 12th Street Kansas City, Missouri 64105 Technical Specifications CONTACT INFORMATION Stephanie Spatz-Ornburn, Event Manager Lee Saylor, Technical Director Business Office: (816) 842-5500

More information

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Les Docks / Av. de Sévelin Lausanne. Technical Rider Technical Rider Technical Rider «Les Docks», updated 20.10.2017 1. Address / Contact Address : LES DOCKS Av. de Sévelin 34 (zone B) 1004 Lausanne Switzerland Phone : +41 21 623 44 44 Fax : +41 21 623 44

More information

General & Technical Specifications

General & Technical Specifications General & Technical Specifications Physical Address: Seating Capacity Proscenium Opening: Stage Depth: Stage Width: Stage Height: Orchestra Pit: Stage Floor: Crossover: Loading door: NE San Carlos Street

More information

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5 Lighting -Lighting control PC with Horizon software and a 24 sub master wing. 2 Universes of DMX distributed via PathPort nodes. Our standard rep plot features 2 full stage back light washs of 20 PAR 64

More information

SHOWBOX SODO TECHNICAL SPECIFICATIONS

SHOWBOX SODO TECHNICAL SPECIFICATIONS SOUND FOH SPECS SHOWBOX SODO TECHNICAL SPECIFICATIONS *** AVAILABILITY OF ALL ITEMS SUBJECT TO PRODUCTION ADVANCE. *** AUDIO POWER 100amp 3 phase power on cam locks available for touring acts. This service

More information

Music Hall of Williamsburg

Music Hall of Williamsburg Venue Info Music Hall of Williamsburg 66 North 6th St. (between Kent and Wythe) Brooklyn, NY 11249 Ph.718-486-5407 / Fax 718-486-5410 www.musichallofwilliamsburg.com Capacity 650 Parking We cannot reserve

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated Technical Rider Technical Rider Docks, updated 17.10.18 1. Address / Contact Address : LES DOCKS Av. de Sévelin 34 (zone B) 1004 Lausanne Switzerland Phone : +41 21 623 44 44 Fax : +41 21 623 44 45 Website

More information

SPECIAL EVENTS AVALON TYPES OF EVENTS

SPECIAL EVENTS AVALON TYPES OF EVENTS A LITTLE HISTORY In 2002 the original Hollywood Playhouse, and previously infamous Palace, was transformed by a state-of-the-art face lift; orchestrated at the hands of owner John Lyons. Without compromising

More information

Project manager (PM): Pamela Næss Mail: Phone:

Project manager (PM): Pamela Næss Mail: Phone: TECHNICAL SPECIFICATIONS FOLKETEATERET OSLO AS STORGATA 21-23, 0184 OSLO NORWAY (LOAD IN THROUGH CARPORT AT YOUNGSTORGET 2) CAPACITY 1395 PEOPLE 764 ORCESTRA AND 615 BALCONY 2x6 seat boxes on orchestra,

More information

TECHNICAL REQUIREMENTS

TECHNICAL REQUIREMENTS BY CHRISTIANE JATAHY TECHNICAL REQUIREMENTS This technical file is the basic technical requirements for a standard venue. They are indicative and will be completed according to particular venues, by means

More information

Technical Specifications

Technical Specifications Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts

More information

Technical Director of Production Andrew Quick Ext 252

Technical Director of Production Andrew Quick Ext 252 Technical Specification NST City April 2018 General Information Address NST City 144 Above Bar St Southampton SO14 7DU Contact Information Administration: 023 8031 5500 Box Office: 023 8067 1771 info@nstheatres.co.uk

More information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION HALLE BIG CONCERT ROOM 900 PAX RAUMBAR SMALL CONCERT ROOM 200 PAX Kulturfabrik Kofmehl Solothurn Version 6.0 Oktober 2017 Contact Kulturfabrik Kofmehl Verein Creep Kofmehlweg 1

More information

RIDER 2018 version 1 English

RIDER 2018 version 1 English PLEASE READ THIS ATTACHMENT CAREFULLY. THIS WILL PREVENT MISCOMMUNICATION AND DELAYS ON CONCERT DAY. THANK YOU FOR YOUR COLLABORATION. General information: Management : Jordi Deckers (INFINITE MUSIC) jordi@infinitemusic.nl

More information

Ed Blackwell Production Manager Mike Weller Head of Music

Ed Blackwell Production Manager Mike Weller Head of Music Contact Details: Ed Blackwell Production Manager Tech@electricbrixton.uk.com 07809697726 Mike Weller Head of Music Mike.weller@electricbrixton.uk.com 07740175585 Michael Yardy General Manager michael.yardy@electricbrixton.uk.com

More information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018 GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither

More information

Technical Information

Technical Information Technical Information Gracie Fields Theatre, Oulder Hill Leisure Complex, Hudsons Walk, Rochdale, Lancashire OL11 5EF Administration: Nikki Jackson Theatre Manager T: 07824 374913 E: nikki@graciefieldstheatre.com

More information

Jane Mallet Theatre Technical Specifications

Jane Mallet Theatre Technical Specifications TECHNICAL SPECIFICATIONS Stage Technician Unions Stage I.A.T.S.E. Local 58 Stage Door Entrance Scott Street (West side of building South of Front St.) Seating Capacity Lower Orchestra 252 Cross Aisle*

More information

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné Technical specifications - Compagnie José Besprosvany Prométhée enchaîné Should you encounter any problems with these specifications, please let us know as soon as possible so that we can work on finding

More information

Theatre Technical Specification

Theatre Technical Specification Theatre Technical Specification The information contained in this specification details the standard technical provision offered by the Brewhouse for visiting companies, artists and hirers. It details

More information

The Taal Inc. Rhythm Ensemble Tech Rider

The Taal Inc. Rhythm Ensemble Tech Rider The Taal Inc. Rhythm Ensemble Tech Rider In case of any queries regarding sound please contact Janak on +91 9595 680 886 Email: janak@taalinc.net Please go through the full technical rider (including the

More information

2017 TECHNICAL SPECIFICATIONS

2017 TECHNICAL SPECIFICATIONS 2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au

More information

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2016 Zach Vander Missen Muhammad Farooq Garrett McMindes Outline Primary System Design Constraints Venue Illustration System

More information

PRODUCTION BIBLE. last update November 2015

PRODUCTION BIBLE. last update November 2015 PRODUCTION BIBLE last update November 2015 FOR THE LATEST VERSION OF THIS DOCUMENT PLEASE DOWNLOAD IT FROM www.viperclub.eu/files/vipertheatre-productionbible.pdf We welcome you to the Viper theatre and

More information

Technical Specification

Technical Specification Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium

More information

Technical Specification. Updated: April 2016

Technical Specification. Updated: April 2016 Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:

More information

The Temple Hoyne Buell Theatre

The Temple Hoyne Buell Theatre The Temple Hoyne Buell Theatre Venue and Technical Guide The Temple Hoyne Buell Theatre The Temple Hoyne Buell Theatre is designed to provide the audience with a first-rate theatrical experience featuring

More information

Technical Information

Technical Information 5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members

More information

National Folk Festival PA Specs 2018 MARQUEE

National Folk Festival PA Specs 2018 MARQUEE Date National Folk Festival PA Specs 2018 Thursday 29 March - Monday 2 April 2018 Site Access Bump In Bump Out Concert Times Friday 30 March - Sunday 1 April Monday 2 April Venue Requirements from 9am

More information

UTE LEMPER LAST TANGO IN BERLIN Accompanied by Piano and Bandoneon, Domestic Rider

UTE LEMPER LAST TANGO IN BERLIN Accompanied by Piano and Bandoneon, Domestic Rider This rider is to be attached and made part of the contract dated _ between Ute Lemper (hereinafter referred to as ARTIST ) and _ (hereinafter referred to as PURCHASER ). PLEASE READ THIS RIDER CAREFULLY.

More information

Access to back stage is off Fletcher St on the eastern side of the building

Access to back stage is off Fletcher St on the eastern side of the building BYRON TECHNICAL SPECIFICATIONS JUNE 2013 VENUE OVERVIEW A studio style theatre with a capacity of 246, this venue is as pleasurable for performers as it is for the audience. The theatre is an ideal space

More information

THEATRE EQUIPMENT DECEMBER 2017

THEATRE EQUIPMENT DECEMBER 2017 THEATRE EQUIPMENT DECEMBER 2017 Stage Stage opening (permanent): width 10m & height 6m Proscenium opening (adjustable): width 9m 11m Proscenium bridge: adjustable in height Working height underneath the

More information

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m) General info Public Entrance Atlantisplein 1 Loading dock Arcadia Left side of the building. Ramp available. *elevator available (1,4m x 3,3m) Zip-code 1093 NE City Amsterdam Telephone Front desk 020-7606780

More information

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram Get Funked Compact 6-piece Technical Rider 2017/18 Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram Contact Martyn Strange Tour Manager UK cell phone: +44

More information

Theatre Technical Specifications

Theatre Technical Specifications Theatre Technical Specifications The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height

More information

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy Festival City Theatres Trust Festival Theatre Technical Specification Smoking Policy It is the policy of Festival City Theatres Trust that all of our workplaces are smoke-free and all employees and visiting

More information

Technical Specifications Nov 2016

Technical Specifications Nov 2016 Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The

More information

Anvil Theatre. Technical Information

Anvil Theatre. Technical Information Anvil Theatre Technical Information Seating Anvil Theatre has a variable seating configuration system. This allows for 4 different seating configurations: - Full Seating, gives a standard theatre style

More information

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062 Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062 General Specifications Mabee Performing Arts Hall The Mabee Performing Arts Hall is located in the Bell Cultural

More information

Production Gaël Perrot + 33 (0) Agent Simon Nodet + 33 (0)

Production Gaël Perrot + 33 (0) Agent Simon Nodet + 33 (0) LA CARAVANE PASSE TECHNICAL RIDER Tour Manager Guillaume «PanPan» Panhelleux +33 (0) 6 66 30 93 95 gpanhelleux@gmail.com FOH Engineer Nicolas Bouchillou +33 (0) 6 62 67 90 36 nicodonf@free.fr Production

More information

Technical Specifications

Technical Specifications Technical Specifications 3865 North Wickham Road Melbourne, Florida 32935 Main Office (321) 433-5719 Ticket Office (321) 242-2219 Rob Adams Technical Operations Director (321) 433-5822 adamsro@easternflorida.edu

More information

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15 Technical Rider Updated 21/10/15 1. ADRESS / CONTACTS Address: Website: La Gravière Chemin de la gravière 9 1227 Acacias, Genève Switzerland www.lagraviere.net Technical Cyril Borde Phone: + 41 77 493

More information

Rider Part1: Technical Requirements, A Cappella Show

Rider Part1: Technical Requirements, A Cappella Show Rider Part1: Technical Requirements, A Cappella Show The Swingles agree to provide, at no cost to the promoter:* 1. 10 channel wireless microphone system (AKG WMS4500: 650-710MHz) 2. 8 mix wireless IEM

More information

Technical Specifications

Technical Specifications Technical Specifications Updated Curatorial Statement is a Page 2 of 14 Theatre Stage Description: The Theatre is a flat floor space on the First Floor of the former Geelong Law Courts with 128 seat retractable

More information

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com PHOTO : SÉBASTIEN DION TECHNICAL RIDER A PROPERTY OF ADRESS 252, rue Saint-Joseph Est Québec (Québec) MANAGEMENT 240, rue Saint-Joseph Est Québec (Québec) G1K 3A9 General phone: 418.523.2227 FAX: 418.523.4449

More information

Z SPACE Technical Specifications. Stage & Rigging

Z SPACE Technical Specifications. Stage & Rigging Stage & Rigging Stage D anser Sprung Oak Dance Floor treated with Masonite and Roscoe marley dance flooring Dimensions: 43 w x 64 d. Rep. stage layout is as follows: Rear Projection Screen (15 h x 26.5

More information

068 VENUE

068 VENUE 068 VENUE VENUE 069 MALMÖ MALMÖ OPERA HOUSE MALMÖ OPERA HOUSE COULD BE DESCRIBED AS PART OF THE FURNITURE BY SWEDISH INHABITANTS, IT HAS BEEN A DISTINGUISHABLE LANDMARK FOR MORE THAN 50 YEARS. IT HAS RECENTLY

More information

Technical Specification for the Alley Theatre, Strabane

Technical Specification for the Alley Theatre, Strabane Technical Specification for the Alley Theatre, Strabane All technical requests should be made to Andrew Orr, Technical Officer. Contact Details Andrew Orr The Alley Theatre, Railway St, Strabane, BT82

More information

Thank you for thinking of The Fonda Theatre for your private event!

Thank you for thinking of The Fonda Theatre for your private event! Thank you for thinking of The Fonda Theatre for your private event! We have been in the business of making dreams and ideas a reality for a very long time, and we look forward to doing the same with yours.

More information

TECHNICAL RIDER SUPERVISION

TECHNICAL RIDER SUPERVISION TECHNICAL RIDER SUPERVISION Input List Ch N Instrument Transducer Insert 1 Kick β52 / D 112 β91 (+ β52) Gate-Comp 2 Snare 1 Top SM 57 Gate-Comp 3 Snare 2 Top SM 57 Gate-Comp 4 Hi-Hat C 451B - 5 Tom 1 MD

More information

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony. ANVIL CENTRE THEATRE S technologically advanced, flexible space is ideal for performing arts productions, dance recitals, music shows, digital and analog presentations, cabarets, banquets, and business

More information

Marjorie S. Deane Little Theater

Marjorie S. Deane Little Theater THEATER LOCATION Marjorie S. Deane Little Theater Public access at 5 West 63 rd street, New York, NY 10023. performances only at 10 West 64 th street. Directions to Loading Entrance at 10 West 64 th street:

More information

Patriots Theater at the War Memorial Technical Data

Patriots Theater at the War Memorial Technical Data Patriots Theater at the War Memorial Technical Data Stage House Dimensions Proscenium Opening: 50-0 wide x 25-0 high Batten Travel: 48-10 Batten Length: 60-0 Stage depth: 26 smoke pocket to back wall Pit

More information

Summary. Access and Parking

Summary. Access and Parking 1 Summary Cornerstone arts centre consists of the main house which is 217 seat end on format with raked seating. An extra row (AA) of flat floor seating can be added giving a capacity of 234. The stage

More information

Visy Theatre technical information and general specifications 2019

Visy Theatre technical information and general specifications 2019 Visy Theatre technical information and general specifications 2019 General Information THEATRE ACCESS Artist access to the Visy Theatre is via either the lower loading dock or through the backstage doors

More information

RPAC REDLANDS PERFORMING ARTS CENTRE

RPAC REDLANDS PERFORMING ARTS CENTRE RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and

More information

HAROLD SHENKMAN HALL 2017 TECHNICAL SPECIFICATIONS

HAROLD SHENKMAN HALL 2017 TECHNICAL SPECIFICATIONS The 500-seat Harold Shenkman Hall is a fully serviced performance venue, which can be used to feature music, theatre, dance, choirs, conferences, film/video screenings, literary events, and other presentations.

More information

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax 1400 MARKET STREET ST LOUIS, MISSOURI 63103 314-499-7600 Main Number 314-499-7601 Main Fax www.peabodyoperahouse.com MATTHEW DEWEY GENERAL MANAGER Tel: 314-499-7700 Cell: 913-209-5148 Email: mdewey@peabodyoperahouse.com

More information

Roberto SOLO Fonseca

Roberto SOLO Fonseca This is the Rider for Mr. Roberto Fonseca. Please read it carefully and return it signed. COMPLETE RIDER INTRODUCTION This rider is part of the contract and will be signed ON EACH PAGE and attached to

More information

ROSE THEATRE MAIN THEATRE

ROSE THEATRE MAIN THEATRE ROSE THEATRE MAIN THEATRE SEATING The total capacity of the Main Theatre is 300 (4-6 restricted view seats) STAGE Performing area - front section 6500mmx3000mm. Rear section 6000mm x 3000mm Rear section

More information