Accuracy improvement of indenting test results by using wireless cable indenting robot

Size: px
Start display at page:

Download "Accuracy improvement of indenting test results by using wireless cable indenting robot"

Transcription

1 Journal of Mechanical Science and Technology 6 (9) (0) 7~70 DOI 0.007/s Accuracy improvement of indenting test results by using wireless cable indenting robot Kyung-Nam Jang, Jong-Soeg Kim, Sun-Chul Jeong, Kyung-Heum Park and Sung-Yull Hong,* Korea Hydro & Nuclear Co., LTD, Central Research Institute, Daejeon, Korea School of Mechanical Engineering, Yeungnam University, Gyeongsangbuk-do, Korea (Manuscript Received March 8, 0; Revised April, 0; Accepted May, 0) Abstract In nuclear power plants, there are many cables that perform safety-related functions. These cables should implement condition monitoring during the operation period in the NPP, in order to assess the remaining qualified life and extend the qualified life. In this study we focused on the indenting method, which can measure the hardness of the cable jacket. This method is selected because it is nondestructive and requires short testing time and small sized equipment. In order to address the problems of the existing indenting test equipment, we developed new indenting test equipment, which could automatically move on the surface of the object cable. The newly developed equipment is designed for a small-sized and lightweight robot using wireless communication in order to implement condition monitoring in a harsh environment or locations that are inaccessible to the tester. The developed wireless cable indenting robot is composed of three parts, mechanical and electrical hardware parts and remote-control part. In order to verify accuracy improvement of indenting test data, an indenting test for cable specimens using both existing indenting test equipment and wireless cable indenting robot was performed. Analysis of the indenting test results shows that the accuracy of the results obtained using the wireless cable indenting robot is improved remarkably. Keywords: Condition monitoring; Safety-related cable; Indenting test; Wireless communication Introduction * Corresponding author. Tel.: , Fax.: address: syhong@yu.ac.kr Recommended by Editor Jai Hak Park KSME & Springer 0 In nuclear power plants (NPP), there are lots of safetyrelated equipment, including cables. The owner of NPP should demonstrate with reasonable assurance that all the safetyrelated equipment for which a qualified life or condition has been established can perform their safety function without experiencing common-cause failures before, during, and after applicable design basis events. For this reason, all the safetyrelated equipment including cables under the harsh environment should perform the equipment qualification (EQ) and condition monitoring until the end of the qualification life according to IEEE std []. In particular, condition monitoring is a very useful method to extend the qualified life of equipment or cable installed in NPP. Among the safety-related equipment installed in NPP, we focused on condition monitoring of cables which is the one of the most important tasks in order to extend the qualified life of the cables. In this paper, we introduce a wireless cable indenting robot that can perform non-destructive condition monitoring of cables installed in NPP, and compare the performance with that provided by other indenting test equipment.. Indenting test equipment for condition monitoring. Condition monitoring of cables The condition monitoring program requires that the characteristics subject to aging deterioration be monitored at specific intervals and compared with specified acceptance criteria. The acceptance criteria shall be based on post-age-conditioning characteristics for the qualified cable []. NRC Regulatory Guide. requires that condition monitoring should be implemented for safety related power, instrumentation and control cables and recommends that condition monitoring programs may include any appropriate technique, supplemented with walkdowns to look for visible signs of anomalies attributable to aging with particular emphasis on the identification of localized adverse environments or hot spots []. Draft Regulatory Guide DG-0 published in US NRC introduces condition monitoring techniques for electric cables used in nuclear power plants []. Among the many methods available for condition monitoring, we used the indenting method, which can measure the hardness of the cable jacket; this method is non-destructive and requires short test time and

2 76 K.-N. Jang et al. / Journal of Mechanical Science and Technology 6 (9) (0) 7~70 Table. Indenting test results obtained using existing indenting test equipment. (Unit : g f/mm) (a) Developed by EPRI Fig.. Existing indenting test equipments. (b) Developed by KEPRI Tester No. Specimen No. Average Average 7 7 Fig.. Irregularity of the cable surface. Fig.. Test specimens. small sized equipment. In 99, EPRI developed the first cable indenter that can measure the hardness of the cable jacket, as shown in Fig. (a) []. In 00, KEPCO Research Institute (KEPRI) developed a computer (PDA) equipped cable indenter that uses same methodology as the indenter produced by EPRI, as shown in Fig. (b) [6]. Specimen Specimen Specimen Specimen Specimen Fig.. Enlarged cable surface pictures of specimens.. Problems of existing indenting test equipment In order to identify problems of existing indenting test equipment, we performed indenting tests using the KEPRI developed indenting test equipment for different types of specimens, as shown in Fig.. Three testers were selected, and each tester performed an indenting test 0 times per specimen. The results of the tests showed that the average of variation was 7 g f /mm. The specific results are provided in Table. It was found that the existing indenting test equipment suffered problems of low reproducibility and large variation of test data. These problems are caused by human error, irregularity of cable samples and measurement error in the results of the analysis of the test data. First, with regard to human error, the angle of insertion of the indenting probe to the cable surface can influence the test results. In each test, the angle of insertion may be different because the tester should clamp and release the cable specimen whenever performing the test. Also, the clamping skill of each tester is a critical factor. Second, irregularity of cable samples can influence the test results. The enlarged cable surface picture shown in Fig. (a) Fig.. Problem of indenting test for multi-core cable. reveals that the cable surface is uneven. Hence, according to the position of the cable surface, which the indenting probe contacts, the indenting test results may be different. Observing a 00x enlarged picture of each cable specimen surface by microscope, as shown in Fig., it is found that specimens and have rather even surfaces, but specimens,, and have rather uneven surfaces. From an analysis of the test results according to the cable specimens, as shown in Table, specimens that have uneven surfaces have a two-fold greater amount of large variations. In addition, most cables are multi-core type, meaning they have more than two cores in the cable jacket, as shown in Fig.

3 K.-N. Jang et al. / Journal of Mechanical Science and Technology 6 (9) (0) 7~70 77 (a) Normal data Fig. 6. Normal and abnormal indenting test data. (b) Abnormal data (a) Scheme of the system Fig. 7. Wireless cable indenting robot. (b) Wireless cable indenting robot. Because the indenting test entails pressing the cable jacket with the indenting probe and measuring the pressing force and the indented depth, the existence of a core under the measuring position can influence the test results. Lastly, measurement error can lead to large variation of the test results. Measurement error can be found from the graph of pressing force and indented depth. Normally, as shown in Fig. 6(a), as the pressing force increases, the indented depth accordingly increases. However, when measurement error occurs, the indented depth is decreased during the indenting test, as shown in Fig. 6(b). If data obtained under circumstances of measurement error are included in the test results, the accuracy of the test results will be decreased. (a) Indenting module (b) Moving module. Development of wireless cable indenting robot Our aim is to develop new cable indenting test equipment that can resolve the problem of existing indenting test equipment. Furthermore, we considered that most cables in NPP are installed in harsh environments or spaces that tester cannot access. To address the first problem of human error and second problem of irregular cable surface, we designed a robot that can move on the surface of the cable and perform indenting test automatically. If the robot can clamp and release the object cable for itself, and can perform the indenting test in next position automatically, human error from repeated testing and the requirement of testing skill can be avoided. Also, if the robot can acquire abundant data quickly, representative value of indenting test results can be selected using a statistical method, regardless of irregularity the of cable surface.. System of wireless cable indenting robot We focused on designing a small-sized and lightweight robot, because the robot should travel along the surface of the object cable. Furthermore, in order to perform testing in harsh environment or space that tester cannot access, the robot should be wirelessly operated from a control system. As shown in Fig. 7(a), the robot system is composed of a cable indenting robot including mechanical hardware part and electrical hardware part, and remote-control part. The cable indenting robot communicates with the remote-control part (laptop PC or mobile device) using Bluetooth communication. The developed wireless indenting robot is shown in Fig. 7(b). Fig. 8. Mechanical hardware part. (c) Clamping module. Mechanical hardware part The mechanical hardware part is composed of an indenting module, moving module, and clamping module. The indenting module performs indenting test with an indenting probe and is located at center of the robot. The indenting probe can move down perpendicularly via use of a DC servo motor and spur gears. The pusher and spring flatten the cable surface so that the probe remains at right angles with the cable, as shown in Fig. 8(a). From the results of indenting test, the modulus value (g f /mm), which is the force per indented depth, is obtained. After the indenting test, the indenting module returns the original position, in order to perform the next test. The moving module moves on the surface of the object cable. This module consists of two DC-servo motors and wheels with a Viton-ring, in order to move on the surface of the cable smoothly, and an assist wheel to move straight, as shown in Fig. 8(b). The robot can automatically move with constant intervals for continuous indenting testing. The clamping module can clamp the cable during the indenting test and helps the robot move straight along the surface of the cable. The clamping module consists of two DC-servo motors, a V-block, and ball screw bearings, as shown in Fig. 8(c).

4 78 K.-N. Jang et al. / Journal of Mechanical Science and Technology 6 (9) (0) 7~70 Fix the Robot on Installed Cable Calculate Modulus Acquire Indenting Test Data No The Number of Test > 0? The Data is Normal? Yes No Delete Data Yes Determine Representative Value Evaluate Degradation Level Comparing with Unique Cable Database Fig.. Procedure for indenting test. applied, and also a mobile device with a Bluetooth module can be applied. The control program was coded by Visual C++, divided into a communication & control panel, data display panel, and state display panel, as shown in Fig. 0.. Indenting test algorithm Fig. 9. The concept of the electrical hardware part. Fig. 0. Remote control program.. Electrical hardware part The electrical hardware part is composed of a motor control module, power supply module, and wireless communication module. The concept of the electrical hardware part is illustrated in Fig. 9. The PCB is designed for triple floors in order to minimize occupied space. As the main controller, a DSP with 0 MIPS is applied. A Li-ion battery that has capacity of 7.V and 900 mah is applied for the power supply. The output voltage is divided into voltages of. and V for the controller and motor driving powers using a transforming circuit. For wireless communication, a Bluetooth module that has a communication standard of the.0 version and. GHz ISM band is applied. This module can communicate with the remote-control part within a range of 00 m.. Remote-control part The remote-control part can command the cable indenting robot to perform the indenting test and receive the indenting test results. For the remote-control part, a laptop computer is In order to minimize measurement error, we propose an algorithm that eliminates abnormal data shown in Fig. 6(b). We focused on the linear relation between the measured force and indented depth. When the indenting test is completed, the measured force and indented depth data are transferred to the remote-control program. Linear fitting for the force and depth relation using the least mean square method is performed, and the least mean square error is calculated. If the least mean square error exceeds selected criteria, it is determined that the relation between force and depth is not linear. In this algorithm, test data having large least mean square error is deleted as it is deemed erroneous. The indenting test using the wireless cable indenting test robot follows the procedure shown in Fig.. At the start of the test, the robot should be fixed on the object cable. According to the signal of the starting test, the robot performs the indenting test. Once the first indenting test is completed, the result data are transferred to the remote-control program and assessed in terms of whether they are normal or abnormal data using the abnormal data detection algorithm. If the test data are normal data, a modulus value is calculated and restored. This sequence is repeated 0 times while the robot moves on the surface of the object cable automatically. Finally, a representative modulus is selected by a statistical method, and the remaining lifetime or degradation level is evaluated through comparison with the unique database of the object cable.. Test results of indenting test using the wireless cable indenting robot An indenting test using the wireless cable indenting robot was performed in order to assess how much the accuracy of the test results was improved. Test specimens were the same those described in Section. Three testers, also corresponding with those in Section, were selected, and each tester performed indenting test 0 times per specimen, according to the procedure in Fig.. The results of the tests showed that the

5 K.-N. Jang et al. / Journal of Mechanical Science and Technology 6 (9) (0) 7~70 79 Table. Indenting test results obtained using wireless cable indenting robot. (Unit : g f/mm) Tester No. Specimen No. Sa mp l e M e a n Pe r c e n t Sa m p le S t D e v Average Average Gage R&R (ANOVA) for Existing equipment Gage R&R Repeat Reprod S Chart by Tes t er Com pone nt s of Variat ion X bar Chart by Tes te r Part-to-Part % Contribution % Study Var UCL=7. S=0.0 LCL=8.7 UCL= X= LCL=7 S p e c i me n average of variation was.9 g f /mm, as shown in Table. In order to verify the accuracy of the developed robot system, we performed a Gage R&R analysis for both the test data using existing indenting test equipment in Table and the test data using the wireless cable indenting robot in Table with Minitab Statistical Software. The Gage R&R analysis results are presented in Fig. and Fig., respectively. In the case of the existing indenting equipment, the total Gage R&R study variation percentage was.86%. The repeatability and the reproducibility were.8% and.0%, respectively. In the case of the wireless cable indenting robot, the results of the Av e r a g e E x is t ing e quipm ent by S pe cim en E x is ting equipme nt by Tes t er T e st e r S pecim en * Tes t er Int eract ion Sp e c i m e n Fig.. Gage R&R results for existing indenting test equipment. Gage R&R (ANOVA) for Developed Equipment Sa mp l e M e a n Pe r c e n t Sa m p le S t D e v Com pone nt s of Variat ion % Contribution % Study Var 0 Gage R&R Repeat Reprod Part-to-Part S Chart by Tes t er 0 UCL=.60 0 S=8. 0 LCL=. X bar Chart by Tes te r UCL=68 X=0 LCL= Av e r a g e D ev elope d E quipm ent by S pecim en S p e c i me n D ev eloped E quipm ent by Tes t er T e st e r S pecim en * Tes t er Int eract ion Sp e c i m e n Fig.. Gage R&R results for wireless cable indenting robot. Tester Tester analysis showed that the total Gage R&R study variation percentage was.%. Because the criterion for the study variation percentage is 0%, it is found that the developed robot system is stable. In particular, the repeatability and the reproducibility present the accuracy of.6% and.%, respectively. From the analysis of Gage R&R, it is found that the accuracy of the developed robot system is improved remarkably. From a quantitative point of view, the average of variation is reduced by 8%, from 7 g f /mm to.9 g f /mm. The reason that the variation average is different for each specimen is that the representative modulus value is different. Representative modulus value of specimen, is more than twice that of specimen. Thus, as the modulus value becomes higher, the variation of the test data accordingly increases.. Conclusions In order to assess the remaining lifetime of cable and extend the cable lifetime, condition monitoring using an indenting test method, which is measures the hardness of the cable jacket, will be implemented. The existing indenting test equipment suffers some problems, including large variation of test results, because of human error, irregularity of cable samples, and measurement error, as seen in the results of an analysis of the test data. This reduces the accuracy of estimation of the remaining lifetime of the cable. In this paper, in order to improve the accuracy of the indenting test results, we have introduced a new concept for cable indenting equipment that can automatically move on the surface of the object cable. If the robot can clamp and release the object cable for itself, and can perform the indenting test in next position automatically, human error from repeated testing and the requirement of testing skill can be avoided. Also, if the robot can acquire abundant data quickly, representative value of indenting test results can be selected using a statistical method, regardless of irregularity the of cable surface. Furthermore, the newly developed equipment is designed for a small-sized and lightweight robot using wireless communication in order to implement condition monitoring in harsh environment or location that the tester cannot access. In order to minimize the measurement error, we applied an abnormal detection algorithm to exclude the abnormal test data, in the procedure of the indenting test. We performed an indenting test for cable specimens using both existing indenting test equipment and wireless cable indenting robot, respectively, in order to verify the accuracy improvement of indenting test data. From the results, the average variation of test data was reduced by 8%, from 7 g f /mm to.9 g f /mm. It is found that the accuracy of the indenting test data is remarkably improved by using the wireless cable indenting robot. In the future, if a database of all safety-related cables installed in NPP is constructed, indenting test using the proposed wireless cable indenting robot will play an important role in condition monitoring of those cables.

6 70 K.-N. Jang et al. / Journal of Mechanical Science and Technology 6 (9) (0) 7~70 References [] IEEE std -00, IEEE standard for qualifying class E equipment for nuclear power generating stations, IEEE Power Engineering Society (00). [] IEEE std 8-00, IEEE standard for qualifying class E electric cables and field splices for nuclear power generating stations, IEEE Power Engineering Society (00). [] Regulatory Guide., Qualification of safety-related cables and field splices for nuclear power plants, U.S. Nuclear Regulatory Commission (009). [] Draft Regulatory Guide DG-0, Condition monitoring program for electric cables used in nuclear power plants, U.S. Nuclear Regulatory Commission (00). [] EPRI, Cable indenter aging monitor, EPRI NP-78, Electric Power Research Institute (99). [6] J. S. Kim, Evaluation of cable life based on condition monitoring, 0 fall meeting of Korean nuclear society (00). Kyung-Nam Jang was born in Gwangju, Korea, in 977. He graduated from Jeonnam National University, Korea, in 00, and received his M. S. degree from Korea Advanced Institute of Science and Technology, Korea, in 00. He works as a Researcher at KHNP Central Institute and is interested in equipment qualification. Jong-Seog Kim was born in Busan Korea, in 99. He received his Ph.D from Chung-Nam national university in 00. He works as a principal researcher of KHNP Central Institute and is interested in environmental qualification of NPP.

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools International Journal of Engineering and Technical Research (IJETR) ISSN: 2321-0869 (O) 2454-4698 (P), Volume-3, Issue-9, September 2015 Real-time Chatter Compensation based on Embedded Sensing Device

More information

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications Reliability Guideline: Generating Unit Operations During Complete Loss of Communications Preamble It is in the public interest for the North American Electric Reliability Corporation (NERC) to develop

More information

Fieldbus Testing with Online Physical Layer Diagnostics

Fieldbus Testing with Online Physical Layer Diagnostics Technical White Paper Fieldbus Testing with Online Physical Layer Diagnostics The significant benefits realized by the latest fully automated fieldbus construction & pre-commissioning hardware, software

More information

AppNote - Managing noisy RF environment in RC3c. Ver. 4

AppNote - Managing noisy RF environment in RC3c. Ver. 4 AppNote - Managing noisy RF environment in RC3c Ver. 4 17 th October 2018 Content 1 Document Purpose... 3 2 Reminder on LBT... 3 3 Observed Issue and Current Understanding... 3 4 Understanding the RSSI

More information

The use of an available Color Sensor for Burn-In of LED Products

The use of an available Color Sensor for Burn-In of LED Products As originally published in the IPC APEX EXPO Conference Proceedings. The use of an available Color Sensor for Burn-In of LED Products Tom Melly Ph.D. Feasa Enterprises Ltd., Limerick, Ireland Abstract

More information

Team Members: Erik Stegman Kevin Hoffman

Team Members: Erik Stegman Kevin Hoffman EEL 4924 Electrical Engineering Design (Senior Design) Preliminary Design Report 24 January 2011 Project Name: Future of Football Team Name: Future of Football Team Members: Erik Stegman Kevin Hoffman

More information

Automatic Commercial Monitoring for TV Broadcasting Using Audio Fingerprinting

Automatic Commercial Monitoring for TV Broadcasting Using Audio Fingerprinting Automatic Commercial Monitoring for TV Broadcasting Using Audio Fingerprinting Dalwon Jang 1, Seungjae Lee 2, Jun Seok Lee 2, Minho Jin 1, Jin S. Seo 2, Sunil Lee 1 and Chang D. Yoo 1 1 Korea Advanced

More information

Internet of Things Technology Applies to Two Wheeled Guard Robot with Visual Ability

Internet of Things Technology Applies to Two Wheeled Guard Robot with Visual Ability Internet of Things Technology Applies to Two Wheeled Guard Robot with Visual Ability Chih-Hui Chiu and Yu-shiou Huang Abstract In this study, a two wheeled guard robot (TWGR) system with visual ability

More information

FMEA of Cable Failures within a Fire PSA

FMEA of Cable Failures within a Fire PSA FMEA of Cable Failures within a Fire PSA PSAM 9, Hong Kong, 2008/05/19 Joachim Herb and Ewgenij Piljugin Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbh, Forschungsinstitute, 85748 Garching bei

More information

Real-Time Compensation of Chatter Vibration in Machine Tools

Real-Time Compensation of Chatter Vibration in Machine Tools I.J. Intelligent Systems and Applications, 2013, 06, 34-40 Published Online May 2013 in MECS (http://www.mecs-press.org/) DOI: 10.5815/ijisa.2013.06.04 Real-Time Compensation of Chatter Vibration in Machine

More information

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER 9I273 01/10/2012 COU-03/0 1 CONTENTS 1. SPECIFICATIONS... 3 2. BLOCKS DIAGRAM... 3 3. FRONT VIEW... 4 4. REAR VIEW... 4 5. CONTROL MODULE... 4 6. ZONE CARD (COU-03FC or COU-03EC)... 6 6.1. Diagram... 6

More information

Guidelines for Specification of LED Lighting Products 2010

Guidelines for Specification of LED Lighting Products 2010 Guidelines for Specification of LED Lighting Products 2010 September 2010 Introduction With LED s emerging as a new functional light source there is a need to ensure performance claims are made in a consistent

More information

Fluke 279 FC True-rms Thermal Multimeter

Fluke 279 FC True-rms Thermal Multimeter TECHNICAL DATA Fluke 279 FC True-rms Thermal Multimeter 4 ways the Fluke 279 FC will make your job easier 1. Find the problem faster Scan with the thermal imager to find electrical problems rapidly and

More information

Versatile EMS and EMI measurements for the automobile sector

Versatile EMS and EMI measurements for the automobile sector EMC/FIELD STRENGTH EMC Measurement Software R&S EMC32-A Versatile EMS and EMI measurements for the automobile sector EMC Measurement Software R&S EMC32-A (automotive) from Rohde & Schwarz is a powerful

More information

Privacy Level Indicating Data Leakage Prevention System

Privacy Level Indicating Data Leakage Prevention System Privacy Level Indicating Data Leakage Prevention System Jinhyung Kim, Jun Hwang and Hyung-Jong Kim* Department of Computer Science, Seoul Women s University {jinny, hjun, hkim*}@swu.ac.kr Abstract As private

More information

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality G4500 Portable Power Quality Analyser Energy Efficiency through power quality The BlackBox portable series power quality analyser takes power quality monitoring to a whole new level by using the revolutionary

More information

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

National Wire and Cable and National Cable Molding Headquarters Los Angeles California National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation

More information

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum: User manual Website: http://www.we-con.com.cn/en Technical Support: support@we-con.com.cn Skype: fcwkkj Phone: 86-591-87868869 QQ Group: 465230233 Technical forum: http://wecon.freeforums.net/ 1. Introduction

More information

Luminaire SIGNATURE SERIES

Luminaire SIGNATURE SERIES Luminaire SIGNATURE SERIES SIGNATURE SERIES Luminaire Do you need a lot of light? Is your application a sky sign? With maximum brightness and pitch this is the go-to module for oversized channel letters

More information

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements MN9320A Optical Channel Drop Unit Independent Test Access Tool for Comprehensive DWDM Measurements MN9320A Access to DWDM Channels and Traffic at One Location The technique of Dense Wavelength Division

More information

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using. Model: S-4904T/R Wireless HD Transmission System User Manual Please read this User Manual throughout before using. Preface Congratulations on your purchase of this product. Please read this user manual

More information

Real-time QC in HCHP seismic acquisition Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC

Real-time QC in HCHP seismic acquisition Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC Chengdu China Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC Summary High channel count and high productivity bring huge challenges to the QC activities in the high-density and high-productivity

More information

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion ES-Mega MegaBeans Access Control System User Manual / Order No. Device People in Motion Contents 1. General description..3 2. Installation Instructions..4 3. Start-up..4 4. Audible signals..4 5. Operating

More information

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL Revision:1.0 is registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective

More information

Owners SW-LCD 2.0 Manual & Specifications

Owners SW-LCD 2.0 Manual & Specifications Owners SW-LCD 2.0 Manual & Specifications Contents 1. Preface. 19 2. Appearance and Size.20 2.1 Material and Color 20 2.2 Display Size and Installation Size 20 3. Function Summary and Button Definition

More information

A Study of Predict Sales Based on Random Forest Classification

A Study of Predict Sales Based on Random Forest Classification , pp.25-34 http://dx.doi.org/10.14257/ijunesst.2017.10.7.03 A Study of Predict Sales Based on Random Forest Classification Hyeon-Kyung Lee 1, Hong-Jae Lee 2, Jaewon Park 3, Jaehyun Choi 4 and Jong-Bae

More information

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing Universal Journal of Electrical and Electronic Engineering 4(2): 67-72, 2016 DOI: 10.13189/ujeee.2016.040204 http://www.hrpub.org Investigation of Digital Signal Processing of High-speed DACs Signals for

More information

The PEFP 20-MeV Proton Linear Accelerator

The PEFP 20-MeV Proton Linear Accelerator Journal of the Korean Physical Society, Vol. 52, No. 3, March 2008, pp. 721726 Review Articles The PEFP 20-MeV Proton Linear Accelerator Y. S. Cho, H. J. Kwon, J. H. Jang, H. S. Kim, K. T. Seol, D. I.

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current

More information

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC January 2015 Robert Konnik. Nuclear Facilities Preview II

IEEE 383 Standard for Qualifying Electric Cables and Splices for. NPEC January 2015 Robert Konnik. Nuclear Facilities Preview II IEEE 383 Standard for Qualifying Electric Cables and Splices for NPEC January 2015 Robert Konnik Nuclear Facilities Preview II IEEE 383 Background This standard provides guidance for developing a program

More information

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance Table of Contents Introduction................................1 Axial pull test and horizontal shear test............2

More information

Multipurpose Robot. Himanshu Gupta 1, Mohammad Shahid 2

Multipurpose Robot. Himanshu Gupta 1, Mohammad Shahid 2 Multipurpose Robot Himanshu Gupta 1, Mohammad Shahid 2 Himanshu Gupta, Department of E&C Engineering, Sikkim Manipal Institute of Technology (SMIT), Majitar, Sikkim, India himanshu.3h @gmail.com 1 Mohammad

More information

STSW1001T STSW1001R STSW1001 INSTALLATION / USER'S MANUAL

STSW1001T STSW1001R STSW1001 INSTALLATION / USER'S MANUAL A CENTURY OF AUTOMOTIVE VISION SAFETY WIRELESS KIT FOR ROSCO BACKUP CAMERA SYSTEMS STSW1001T STSW1001R STSW1001 INSTALLATION / USER'S MANUAL Wireless Kit For Backup Camera Systems TABLE OF CONTENTS Introduction........................................................

More information

KNX Technical Reference Manual Busch-EnergyControl

KNX Technical Reference Manual Busch-EnergyControl 0073-1-7703 Rev. 02 05.2011 KNX Technical Reference Manual Busch-EnergyControl 6762-500 Efficiency with a future Less consumption and fewer costs pay off for people and the environment. You only need the

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

ADS Basic Automation solutions for the lighting industry

ADS Basic Automation solutions for the lighting industry ADS Basic Automation solutions for the lighting industry Rethinking productivity means continuously making full use of all opportunities. The increasing intensity of the competition, saturated markets,

More information

Product model and standard

Product model and standard Preface Thank you for purchasing the Ikan Blitz 400 HD Wireless Video System. This system features uncompressed high definition video with zero delay. Before using the product, please read this user s

More information

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple

More information

Instruction manual. DALI Gateway art Installation manual

Instruction manual. DALI Gateway art Installation manual Instruction manual DALI Gateway art. 01544 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: Supplement Issue: 7 CD Part Number: 4822 872 3093x Issue Date: 1/19 Print Date: January 2012 Page Count: 9 Revision/Date: 1, 6/12 This supplement contains information necessary to ensure

More information

User manual. Long Range Wireless HDMI/SDI HD Video Transmission Suite

User manual. Long Range Wireless HDMI/SDI HD Video Transmission Suite User manual Long Range Wireless HDMI/SDI HD Video Transmission Suite Preface Thanks for purchasing our Long Range Wireless HDMI/SDI HD Video Transmission Suite. Before using this product, read this user

More information

Session 1 Introduction to Data Acquisition and Real-Time Control

Session 1 Introduction to Data Acquisition and Real-Time Control EE-371 CONTROL SYSTEMS LABORATORY Session 1 Introduction to Data Acquisition and Real-Time Control Purpose The objectives of this session are To gain familiarity with the MultiQ3 board and WinCon software.

More information

Manuel Richey. Hossein Saiedian*

Manuel Richey. Hossein Saiedian* Int. J. Signal and Imaging Systems Engineering, Vol. 10, No. 6, 2017 301 Compressed fixed-point data formats with non-standard compression factors Manuel Richey Engineering Services Department, CertTech

More information

-Technical Specifications-

-Technical Specifications- Annex I to Contract 108733 NL-Petten: the delivery, installation, warranty and maintenance of one (1) X-ray computed tomography system at the JRC-IET -Technical Specifications- INTRODUCTION In the 7th

More information

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz Rev. 5 29 May 2015 Product data sheet 1. Product profile 1.1 General description Silicon Monolitic Microwave Integrated Circuit (MMIC) wideband amplifier with internal matching circuit in a 6-pin SOT363

More information

"shell" digital storage oscilloscope (Beta)

shell digital storage oscilloscope (Beta) "shell" digital storage oscilloscope (Beta) 1. Main board: solder the element as the picture shows: 2. 1) Check the main board is normal or not Supply 9V power supply through the connector J7 (Note: The

More information

SZU OPERATING INSTRUCTIONS SAT NAVI

SZU OPERATING INSTRUCTIONS SAT NAVI SZU 21-00 O P ER ATI N G I N S T R U C T I O N S SAT NAVI Operation Instructions SZU 21-00 Safety Notes Turn off the receiver or any used power supply before installing, to avoid short-circuit. Installation

More information

Installation Guide. HDMI 4x1 Switcher

Installation Guide. HDMI 4x1 Switcher Installation Guide HDMI 4x1 Switcher SY Electronics Ltd, Unit 7, Worrall Street, Salford, Greater Manchester, M5 4TH, United Kingdom Tel: +44 (0) 161 868 3450 Fax: +44 (0) 161 868 3459 The SY-HD-S41 is

More information

WELDING CONTROL UNIT: TE 450 USER MANUAL

WELDING CONTROL UNIT: TE 450 USER MANUAL j WELDING CONTROL UNIT: TE 450 USER MANUAL RELEASE SOFTWARE No. 1.50 DOCUMENT NUMBER: MAN 4097 EDITION: MARCH 1998 This page is left blank intentionally. 2 / 34 TABLE OF CONTENTS SUBJECTS PAGE WELDING

More information

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS Installation Instructions Contents 1.0 Introduction...3 2.0 Safety...3 3.0 In the box...4 4.0 Installation of sensors...5 5.0 Linking transmitter

More information

Monitor QA Management i model

Monitor QA Management i model Monitor QA Management i model 1/10 Monitor QA Management i model Table of Contents 1. Preface ------------------------------------------------------------------------------------------------------- 3 2.

More information

Audio Compression Technology for Voice Transmission

Audio Compression Technology for Voice Transmission Audio Compression Technology for Voice Transmission 1 SUBRATA SAHA, 2 VIKRAM REDDY 1 Department of Electrical and Computer Engineering 2 Department of Computer Science University of Manitoba Winnipeg,

More information

Detecting Medicaid Data Anomalies Using Data Mining Techniques Shenjun Zhu, Qiling Shi, Aran Canes, AdvanceMed Corporation, Nashville, TN

Detecting Medicaid Data Anomalies Using Data Mining Techniques Shenjun Zhu, Qiling Shi, Aran Canes, AdvanceMed Corporation, Nashville, TN Paper SDA-04 Detecting Medicaid Data Anomalies Using Data Mining Techniques Shenjun Zhu, Qiling Shi, Aran Canes, AdvanceMed Corporation, Nashville, TN ABSTRACT The purpose of this study is to use statistical

More information

Table of Contents - 2 -

Table of Contents - 2 - - 1 - Table of Contents 1. Purpose of the guidelines and Disclaimer... 3 2. Scope... 3 3. Forced menu... 3 4. Brightest on-mode condition... 4 5. Peak luminance ratio... 4 6. Hazardous substances... 5

More information

HR7012M / HR7012S. Custom Vehicle Headrests with 7 Slim Style LED LCD Satellite Monitors or Built-in DVD Player for Rear Entertainment HR7012M

HR7012M / HR7012S. Custom Vehicle Headrests with 7 Slim Style LED LCD Satellite Monitors or Built-in DVD Player for Rear Entertainment HR7012M S S P HR7012M / HR7012S Custom Vehicle Headrests with 7 Slim Style LED LCD Satellite Monitors or Built-in DVD Player for Rear Entertainment HR7012M HR7012S Installation Guide 128-9047 IMPORTANT NOTICE

More information

MICROMASTER Encoder Module

MICROMASTER Encoder Module MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified

More information

Materials: Programming Objectives:

Materials: Programming Objectives: Lessons Lesson 1: Basic Chassis Overview TETRIX Getting Started Guide In this lesson, users will learn how to use the elements of the TETRIX system that will be involved in building the basic chassis of

More information

RG NDT INTERNATIONAL INC

RG NDT INTERNATIONAL INC RG NDT INTERNATIONAL INC User Manual 165 Oates Road Houston, Texas 77013 Phone: 713-673-5928 Fax: 713-673-5957 GENERAL OVERVIEW Features two (2) inline inspection stations for the detection of: 1. Transverse

More information

GaAs MULTI-CHIP MODULE MC-7883

GaAs MULTI-CHIP MODULE MC-7883 DATA SHEET GaAs MULTI-CHIP MODULE MC-7883 870 MHz CATV 22 db POWER DOUBLER AMPLIFIER DESCRIPTION The MC-7883 is a GaAs Multi-chip Module designed for use in CATV applications up to 870 MHz. This unit has

More information

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements

A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements DRAFT 6 V4 Standard PRC-006- RFC-01 01/11/11 A. Introduction 1. Title: Automatic Underfrequency Load Shedding Requirements Deleted: Deleted: 10 Deleted: 20 9 2. Number: PRC 006 RFC 01. Purpose: To establish

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

Comparing gifts to purchased materials: a usage study

Comparing gifts to purchased materials: a usage study Library Collections, Acquisitions, & Technical Services 24 (2000) 351 359 Comparing gifts to purchased materials: a usage study Rob Kairis* Kent State University, Stark Campus, 6000 Frank Ave. NW, Canton,

More information

REGO Start&Go USER MANUAL

REGO Start&Go USER MANUAL REGO Start&Go USER MANUAL Version 0 Rev. B of 03/03/16 Page 1 of 15 Introduction The purpose of the manual is to describe all of the steps required to commission and correctly operate the REGO Start&Go

More information

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface DIAS Infrared GmbH Publications No. 19 1 Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface Uwe Hoffmann 1, Stephan Böhmer 2, Helmut Budzier 1,2, Thomas Reichardt 1, Jens Vollheim

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area. BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features

More information

Adaptive Key Frame Selection for Efficient Video Coding

Adaptive Key Frame Selection for Efficient Video Coding Adaptive Key Frame Selection for Efficient Video Coding Jaebum Jun, Sunyoung Lee, Zanming He, Myungjung Lee, and Euee S. Jang Digital Media Lab., Hanyang University 17 Haengdang-dong, Seongdong-gu, Seoul,

More information

OPERATIVE GUIDE P.I.T. PILE INTEGRITY TEST

OPERATIVE GUIDE P.I.T. PILE INTEGRITY TEST OPERATIVE GUIDE P.I.T. PILE INTEGRITY TEST 1 Echotest procedure / PIT Pile Integrity test with MAE ETBT instrument Generals Theory notes Pile Integrity Test (PIT) is a simple non destructive test which

More information

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating Installation Guide For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark

More information

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE JY992D6520B This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4AD and should

More information

New Multi Function Controller

New Multi Function Controller ID TING 7 8 ORI CO., LTD. www.oriondisplay.net ddress: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-85 CTER C1 C2 UTO FUNCTI M REMOTE CTROL User's Manual

More information

Area-Efficient Decimation Filter with 50/60 Hz Power-Line Noise Suppression for ΔΣ A/D Converters

Area-Efficient Decimation Filter with 50/60 Hz Power-Line Noise Suppression for ΔΣ A/D Converters SICE Journal of Control, Measurement, and System Integration, Vol. 10, No. 3, pp. 165 169, May 2017 Special Issue on SICE Annual Conference 2016 Area-Efficient Decimation Filter with 50/60 Hz Power-Line

More information

Design of Vision Embedded Platform with AVR

Design of Vision Embedded Platform with AVR Design of Vision Embedded Platform with AVR 1 In-Kyu Jang, 2 Dai-Tchul Moon, 3 Hyoung-Kie Yoon, 4 Jae-Min Jang, 5 Jeong-Seop Seo 1 Dept. of Information & Communication Engineering, Hoseo University, Republic

More information

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract Interactive Virtual Laboratory for Distance Education in Nuclear Engineering Prashant Jain, James Stubbins and Rizwan Uddin Department of Nuclear, Plasma and Radiological Engineering University of Illinois

More information

Using Extra Loudspeakers and Sound Reinforcement

Using Extra Loudspeakers and Sound Reinforcement 1 SX80, Codec Pro A guide to providing a better auditory experience Produced: December 2018 for CE9.6 2 Contents What s in this guide Contents Introduction...3 Codec SX80: Use with Extra Loudspeakers (I)...4

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002 STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 02 872.01 Description 872.02 Prequalification 872.03 Material Requirements

More information

ELECTRONICS CORP. VOD1021/VOD1022 Drop Down Video TV/Monitor with DVD. Installation Guide

ELECTRONICS CORP. VOD1021/VOD1022 Drop Down Video TV/Monitor with DVD. Installation Guide ELECTRONICS CORP. VOD1021/VOD1022 Drop Down Video TV/Monitor with DVD Installation Guide Important Notice An LCD panel and/or video monitor may be installed in a motor vehicle and visible to the driver

More information

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA NDT Technologies, Inc. Wire Rope Inspection Using proven MFL Technology. NDT Technologies has over 30 years of experience dedicated to developing and improving Wire Rope Inspection equipment and methods.

More information

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE JY992D52801C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX-2DA special

More information

Galaxias. Flex LED display. User Manual

Galaxias. Flex LED display. User Manual Galaxias Flex LED display User Manual Conterts Specifications 2 Dimension 3 Attentions 4 Introduction 5 Transportation 6 Installation 7 Maintenance 10 Troubleshooting 11 01 Specifications on Galaxias Series

More information

OFI Optical Fiber Identifier User s Guide

OFI Optical Fiber Identifier User s Guide OFI Optical Fiber Identifier User s Guide OFI Optical Fiber Identifier User s Guide 2002-2008, AFL Telecommunications, all rights reserved. OFI1-11-1000 Revision A, 05.02.08 Specifications are subject

More information

Project Summary EPRI Program 1: Power Quality

Project Summary EPRI Program 1: Power Quality Project Summary EPRI Program 1: Power Quality April 2015 PQ Monitoring Evolving from Single-Site Investigations. to Wide-Area PQ Monitoring Applications DME w/pq 2 Equating to large amounts of PQ data

More information

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 ) Progressive Scan CCD Color Camera KP-FD30M Specifications ( Revision.1 ) Sep 10, 2004 1. General The KP-FD30M is a single CCD type RGB color camera which utilized the progressive scan CCD image sensor

More information

Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide

Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide 04-1125A Introduction The Dual Antenna Wireless Multi-Channel Expandable HDMI Extender wirelessly transmits HDMI signals

More information

Nuclear Instruments and Methods in Physics Research A

Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research A 623 (2) 24 29 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima

More information

C-MAX. CMM-9301-V3.1S Bluetooth 4.0 Single Mode HCI Module. Description. 1.1 Features

C-MAX. CMM-9301-V3.1S Bluetooth 4.0 Single Mode HCI Module. Description. 1.1 Features Description This Module is limited to OEM installation ONLY The module is a Bluetooth SIG qualified, miniaturised BLE controller module based on EM Microelectronic's low power fully integrated single-chip

More information

The Measurement Tools and What They Do

The Measurement Tools and What They Do 2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying

More information

Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables

Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables Application Notes Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables Author Sudipta Bhaumik Issued June 2014 Abstract This application note describes color identification

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: United Electric One Series Electronic Switch Customer: United Electric Watertown, MA USA Contract No.: UE 05/10-35 Report No.: UE 05/10-35 R001 Version

More information

Using Extra Loudspeakers and Sound Reinforcement

Using Extra Loudspeakers and Sound Reinforcement 1 SX80, Codec Pro A guide to providing a better auditory experience Produced: October 2018 for CE9.5 2 Contents What s in this guide Contents Introduction...3 Codec SX80: Use with Extra Loudspeakers (I)...4

More information

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to published version (if available): /ISCAS.2005.

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to published version (if available): /ISCAS.2005. Wang, D., Canagarajah, CN., & Bull, DR. (2005). S frame design for multiple description video coding. In IEEE International Symposium on Circuits and Systems (ISCAS) Kobe, Japan (Vol. 3, pp. 19 - ). Institute

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

Safety Codes Council Conference Banff C Panel Discussion

Safety Codes Council Conference Banff C Panel Discussion Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives

More information

MANAGING POWER SYSTEM FAULTS. Xianyong Feng, PhD Center for Electromechanics The University of Texas at Austin November 14, 2017

MANAGING POWER SYSTEM FAULTS. Xianyong Feng, PhD Center for Electromechanics The University of Texas at Austin November 14, 2017 MANAGING POWER SYSTEM FAULTS Xianyong Feng, PhD Center for Electromechanics The University of Texas at Austin November 14, 2017 2 Outline 1. Overview 2. Methodology 3. Case Studies 4. Conclusion 3 Power

More information

User s Manual Model WF100 Extension Cable for EXA100

User s Manual Model WF100 Extension Cable for EXA100 User s Manual Model WF100 Extension Cable for EXA100 1st Edition User s Manual Model WF100 Extension Cable for EXA100 1st Edition Safety Precautions Introduction This instruction manual covers the Extension

More information

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1. (51) Int. Cl.

(12) Patent Application Publication (10) Pub. No.: US 2006/ A1. (51) Int. Cl. (19) United States US 20060034.186A1 (12) Patent Application Publication (10) Pub. No.: US 2006/0034186 A1 Kim et al. (43) Pub. Date: Feb. 16, 2006 (54) FRAME TRANSMISSION METHOD IN WIRELESS ENVIRONMENT

More information

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

M4000 Diagnostic Test System For Power Apparatus Condition Assessment Knowledge Is Power SM The World Leader in Diagnostic Test Instruments and Knowledge Services for Electric Power M4000 Diagnostic Test System For Power Apparatus Condition Assessment The world s most advanced

More information

Level Accuracy and Electronic Level Settings of SMIQ

Level Accuracy and Electronic Level Settings of SMIQ Products: SMIQ - Vector Signal Generator Level Accuracy and Electronic Level Settings of SMIQ Most signal generators are equipped with a mechanical attenuator. Those attenuators are exposed to mechanical

More information