1 LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on with Sliding mechanism Black or white INSTALLATION GUIDE LANsense Modular Patch Panel for 24 Snap-in Connectors

2 Document information Document reference Release 2006 Published by Contact address LANsense MPP 1HU empty 24 Snap-ins Clip-on with Sliding 2006 Nexans Cabling Solutions Alsembergsesteenweg 2, b Buizingen Belgium Phone Fax Website info.ncs@nexans.com Important Notice The information contained in this document has been carefully checked and is assumed to be entirely correct and reliable at the time of publishing. However, Nexans Cabling Solutions reserves the right to make such changes to its products or its documentation as it deems necessary, in order to make improvements. Nexans Cabling Solutions rejects all responsibility for the use made of its products or of its documentation. In this document, no mention is made of rights with respect to trademarks or tradenames which may attach to certain words or signs. The absence of such mention, however, in no way implies that there is no protection Nexans Cabling Solutions Installation is to be performed by qualified service personnel

3 LANSENSE MODULAR PATCH PANEL 1 HU EMPTY FOR 24 SNAP-IN CONNECTORS WITH CLIP-ON WITH SLIDING MECHANISM During installation, care of LANmark-6/7 products is much more critical than when installing LANmark-5 or other Nexans Category 5e products. The high levels of performance can only be guaranteed if the installation procedures are followed. Special attention must be given to keep the length of untwist of the pairs. Two patch panels are available depending on the type of connector used. Please verify in the table below if the panel is suited for the connectivity to be installed. The LANmark Snap-in connector with rear cover has to be used for screened solutions in order to ensure contact between the foil of the cable and the clips of the Modular Patch Panel. N LANsense Modular patch panel 1HU, empty, for 24 EVO snap-in connectors, with sliding mechanism and clip-on, Black N LANsense Modular patch panel 1HU, empty, for 24 EVO snap-in connectors, with sliding mechanism and clip-on, White N LANsense Modular patch panel 1HU, empty, for 24 GG45 snap-in connectors, with sliding mechanism and clip-on, Black N LANsense Modular patch panel 1HU, empty, for 24 GG45 snap-in connectors, with sliding mechanism and clip-on, White 1HU 3HU Assemble the cage nuts to both side flanges of the frame or cabinet according to the cabinet layout. Nexans Cabling Solutions Installation Guide LANsense MPP - 3

4 Remove the front plate of the patch panel. Mount the Modular patch panel on the assembled cage nuts. Pull the cables through the rear side of the patch panel. Loosely organise the cables in the patch panel coming from the outlets. Easily fix the cables under the clip-on. Nexans Cabling Solutions Installation Guide LANsense MPP- 4

5 Terminate the connectors on the cables as per the Snap-in Installation Guides Snap the connectors into the Patch Panel by hooking the top of the connector under the front plate Push the back of the connector into its aperture. Important : Make sure to leave the OUTER jacket under the clip-on cable guide. Nexans Cabling Solutions Installation Guide LANsense MPP - 5

6 To remove the connector : put a very small screwdriver under the connector in the hole. Manage and dress the cables into the rack or frame, this will add to the bending radius of the cables and facilitate access to the patch panel post installation when the patch panel is closed after termination. If the cables are dressed and managed into the frame or cabinet with the patch panel closed, it is often not possible to pull the patch panel forward for access later on, due to the tightness of the cables. Keep a minimum of 35 cm distance between the front side of the patch panel and the fixing point of the cables in the cabinet or frame. Nexans Cabling Solutions Installation Guide LANsense MPP- 6

7 When provided, gently prepare the small LANsense I/O cable connector from the back of the patch panel to the front in the centre. Take the front mounting plate. Connect the LANsense I/O cable connector to the connector on the back of this plate. The connector will only fit one way. Gently slide back the Patch Panel into the rack. Close the patch panel using the black fastener clips on the front of the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP - 7

8 Slide in the identification label. Optional tie-wraps can be fitted at the back of the patch panel to fix the cables if needed. Use a tie-wrap to fix the LANsense I/O cable in the middle on the back of the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP- 8

9 Earthing : The Patch Panel is automatically earthed if used in conjunction with the Nexans Quick Mount Cabinet. Where the patch panel is mounted onto a painted or coated frame, two additionnal earthing tags, suitable for 9 mm spade connectors, are available in the patch panel at each end of the clip-on cable guide as indicated with the arrow above. An optional earthing wire connecting the top drawer can be added with a metal screw as shown in the picture. IMPORTANT REMARKS : It is recommended to use a patch guide for each 48 ports. The recommended patch guides are the 1HU ( ) for all installations excluding LANmark-7 (GG45) where the 2HU ( ) must be used. The 2HU patch guide can also be used for LANmark-6 installations if enough space is available in the rack or cabinet. NOTE : Only start testing the links or channels when the connectors are installed in the patch panel. Nexans Cabling Solutions Installation Guide LANsense MPP - 9

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on and Shutters with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel 24 Snap-in Connectors with Sliding mechanism

More information

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU LANmark PCB patch panel, 1HU INSTALLATION GUIDE LANmark PCB patch panel, 1 HU Document information Document reference Release September 2001 Published by Contact address BRO-009 LANmark PP 1HU 0701 Nexans

More information

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box LANmark-OF Zone Distribution Box INSTALLATION GUIDE LANmark-OF Zone Distribution Box Document information Release November 2004 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg

More information

LANmark. Copper Cabling Solutions

LANmark. Copper Cabling Solutions LANmark Copper Cabling Solutions Edition 01/03/2001 Copyright Nexans 2001 Subject to change without prior notice. In this publication, no mention is made of rights with respect to trademarks or tradenames

More information

LANmark-OF ENSPACE Patch Panel

LANmark-OF ENSPACE Patch Panel LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE September 2016 v0.11 LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE Part Number Description Product References NSPACE.PP1U NSPACE.PP2U

More information

HCS - HES Cabling Systems

HCS - HES Cabling Systems HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the

More information

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex

More information

Medium Box for Cable Termination

Medium Box for Cable Termination FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling

More information

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table FIST-GCO2-F INSTALLATION INSTRUCTION GCO2-FC GCO2-FD Content 1 Introduction 2 General 2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table 3 Installation

More information

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes FIST-GCOG2-Dx24 I N S T A L L A T I O N I N S T R U C T I O N FTTH closure for micro-tubes and micro-cables Content 1 Introduction 2 Kit content 3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx24

More information

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block FOSC-450D I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories 2.4 Capacity 3 Preparation of the closure 4

More information

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MO036A N-HNS (Building Node Cabinet) N-HNS (BUILDING NODE CABINET) Contents Product description Technical data ODF Splice module Cabling organisation Cable/tube/fibre handling

More information

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual, Part Number

More information

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements. FIST-GCOG2 I N S T A L L A T I O N I N S T R U C T I O N TC-986-IP Rev A, Mar 2017 www.commscope.com FIST-GCOG2-Dx6 Content 1 Introduction 2 General 2.1 Abbreviations 2.2 Kit contents 2.3 Tools 2.4 Accessories

More information

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Wall Mount Enclosure 8430 Series 3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

Caution. Hanging the Screen:

Caution. Hanging the Screen: Installation Instructions for Laminar and Laminar XL Projection Screens Caution 1. Read Instructions through completely before proceeding; keep them for future reference. Follow these instructions carefully.

More information

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

CONNECTING THE FUTURE 19 LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2

More information

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices Berk-Tek recommends installing a well-designed structured cabling channel per the TIA standards. This includes up to 100

More information

6000 Series Patch Panel Terminating Instructions

6000 Series Patch Panel Terminating Instructions 6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four

More information

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions Robert Burén Product Manager 10G Solutions Nexans Cabling Solutions 1 10 Gigabit Ethernet.Performance 30 GByte can be transmitted within 24 seconds Example: MRI-scan size is 30GB as average A memory device

More information

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions High Density Block BRCP HD BRCP- 128/192/256 pair Installation Instructions Product Introduction The BRCP block is the latest generation of MDF terminal blocks developed by 3M, specifically designed for

More information

Ordering Guide. for FIST-GSS2 product range

Ordering Guide. for FIST-GSS2 product range Ordering Guide for FIST-GSS2 product range Page 1 of 17 Ordering Guide of the Generic Splicing Shelf (FIST-GSS2) This document provides assistance with the selection of shelves for use in FIST cable termination

More information

Cable and Power Management Open-Frame Rack Cable Managers

Cable and Power Management Open-Frame Rack Cable Managers Spec-001 Cable and Power Management Open-Frame Rack Cable Managers CABLETEK Horizontal Cable Manager DCHD shown DCHS4 shown Arrowhead fingers funnel cable into base and hold it securely Vertical and horizontal

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1 Fiber Optic Splice Closure 1. Introduction 1.1 General SAMJIN s SJOF-BS604B protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct buried

More information

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket For use with 3M SLiC Free-Breathing Fiber Optic Closures and Terminals Instructions November

More information

FOSC 450 C6 and D6 Closures

FOSC 450 C6 and D6 Closures FOSC 450 C6 and D6 Closures I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure 1. General Product Information The FOSC 450 C6 and D6 fiber optic splice closures use compressed gel

More information

INSTALLATION INSTRUCTIONS MO023A

INSTALLATION INSTRUCTIONS MO023A INSTALLATION INSTRUCTIONS MO023A Nexans N3S ODF system NEXANS N3S ODF SYSTEM Content Product description Patching frame Splice frame Doors Splice module Patch module Protective cover and label panel Guides

More information

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX FIST-GCO2 INSTALLATION INSTRUCTION TC-574-IP Rev A, Feb 2017 www.commscope.com GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX Content 1 Introduction 2 General 2.1 Abbreviation 2.2 Kit Contents 2.3 Elements

More information

HDBT Installation Guide

HDBT Installation Guide KRAMER ELECTRONICS LTD. HDBT Installation Guide MODELS: Kramer HDBT Cable Recommendations for Usage and Termination Guidelines For the latest information on our products and a list of Kramer distributors,

More information

HDBaseT Installation Guide

HDBaseT Installation Guide Installation Guide This document provides the best practices for installing Ethernet cable with setups. We strongly recommend to use ATEN certified cable (2L-2910) to provide best performance and to guarantee

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

Volition TM RJ45 K5e Jacks

Volition TM RJ45 K5e Jacks Volition TM RJ45 K5e Jacks Part of our 3M Volition Network Solutions, the new K5e range is our ultimate Category 5e hardware component (ISO/IEC 11801, EN 50173 and ANSI/TIA/EIA-568). The K5e jack is a

More information

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6 AUDIO ROOF KIT P/N 2882064, 2882065, 2882066 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please

More information

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1. PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702 SCF611S SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702 SCF611S SUBCARRIER TRANSFER FILTER TABLE OF CONTENTS PAGE SHIPPING INSPECTION 2 MODULE CONFIGURATION 2 INSTALLING MODULES 2-3 CABLING 3 FRONT

More information

RAIL D-SUB BACKSHELLS

RAIL D-SUB BACKSHELLS RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS D-SUB BACK SHELLS /// DATA SHEET RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS TE Connectivity (TE) provide a comprehensive range of ruggedized

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

IP-LINX. Installation Guide

IP-LINX. Installation Guide Installation Guide Installation Guide, 146653-4 Copyright 2017, Telect, Inc. All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 22425 East Appleway Ave. # 11

More information

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly Introduction The Backlight Replacement Kit provides a replacement backlight for the PanelMate

More information

Service Call: Fiber Optic Installation and Repair

Service Call: Fiber Optic Installation and Repair Service Call: Fiber Optic Installation and Repair Tools Required: Tools available from www.bohlinger.biz Cable: Terex P/N 453830 Stripper Block: P/N 65-020-01 Termination Block: P/N 65-020-02 Utility Knife

More information

IP-LINX Fiber :: X-XXXX

IP-LINX Fiber :: X-XXXX Fiber :: 055-797X-XXXX User Manual Telect, Inc. All rights reserved. 146653-A0 Table of Contents Chapter 1: Introduction...3 1.1 Tools Required...3 1.2 Additional Parts...3 1.3 Assemblies...3 Chapter 2:

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

LCS 2 RJ 45 Cat. 6A HD panels and units

LCS 2 RJ 45 Cat. 6A HD panels and units 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1

More information

VITALink Taped Splice Straight Through Crimp

VITALink Taped Splice Straight Through Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink

More information

FIBRE OPTIC CABLE SOLUTIONS

FIBRE OPTIC CABLE SOLUTIONS point2point FIBRE OPTIC CABLE SOLUTIONS Introduction From patch-leads through to cross-site cables, or optical adapters through to patch panels, PPM s one-stopshop approach to fibre optic cable management

More information

LGX Compatible (LSX) Connector Module) User Manual)

LGX Compatible (LSX) Connector Module) User Manual) LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1

More information

3M Cold Shrink Foldback Splice Jacket Kit

3M Cold Shrink Foldback Splice Jacket Kit 3M Cold Shrink Foldback Splice Jacket Kit SJ-FB Instructions! CAUTION Working around energized systems may cause serious injury or death. Installation should be performed by personnel familiar with good

More information

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation OFDC-B8-72 I N S T A L L A T I O N I N S T R U C T I O N Outdoor fiber distribution closure Content 1 Introduction 2 Kit content 3 Closure preparation 4 Cable preparation 4.1 Feeder cable 4.2 Drop cable

More information

Crimp & Cleave Termination Instructions for SEL ST Connectors

Crimp & Cleave Termination Instructions for SEL ST Connectors Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp &

More information

Smart Choices. for Data Center

Smart Choices. for Data Center Smart Choices for Data Center LANmark-OF ENSPACE LANmark-OF Plug&Play LANmark-6 LANmark-6A Modular Patch Panels General Accessories & Tools Zone Distribution Boxes FibreRoute Trunking System Faster deployment

More information

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:

More information

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Product information 19 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s

More information

Installation Instructions

Installation Instructions TECP-30-260 Issue 2 July 2016 Installation Instructions OWB-S OWB-S Small Wall-mounted Box CONTENTS 1. Introduction 2. Kit content 3. Installation Instruction 3.1. Box installation 3.2. Conduit installation

More information

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions 2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE FIBER OPTIC SWING-OUT PATCH PANEL INSTRUCTION

More information

Best Friends General Trading FZE

Best Friends General Trading FZE Welcome to Best Friends General Trading FZE Tel. +97 1 50-5426 202, Fax. +971 6 7407428, info@bestfgt.com, besttrd@eim.ae Infrastructure Product Guide Best fgt is UAE based company, operational for last

More information

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2

More information

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA Glass Fiber Cable The fiber optic cables are used to connect the FM211, FM212, FS211, FS211/N and FS212 and FS212/N FASTBUS modules, enabling the connection of remote substations over large distances with

More information

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep SCdefault 900 Installation instructions SITdefault Upgrade to Premium 300 sound system MONTERINGSANVISNING INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG INSTRUCTIONS DE MONTAGE Accessories Part No. Group

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 SOHO 6-Port CAT5e 568B Data Module SEPTEMBER 2003 JPM1101A CUSTOMER SUPPORT

More information

FT-45 Ordering Information

FT-45 Ordering Information FT-45 Ordering Information FT-45 Feed Thru Modular Plug Crimp Tool Item No. Description 30-495 FT-45 Feed-Thru Modular Plug Crimp Tool 30-4951 FT-45 Replacement Blade Cat 6 Feed-Thru RJ45 Modular Plugs

More information

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1 INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1 WWW.INFRASTONE.COM Contents BLACKSTONE CAT6A U/UTP channel performance Introduction BLACKSTONE CAT6A U/UTP channel

More information

Indoor cabling LAN Cabling Systems

Indoor cabling LAN Cabling Systems Indoor cabling LAN Cabling Systems Table of content Nexans 6 Symbols 7 LAN Cabling Systems 8 Copper 9 Category 5e 10 Essential Cat 5e Cable 11 Essential Patch Panels 14 Essential Outlet Modules 16 Essential

More information

Cabling and Completing Assembly of the Cisco TelePresence System 1000

Cabling and Completing Assembly of the Cisco TelePresence System 1000 CHAPTER 5 Cabling and Completing Assembly of the Cisco TelePresence System 1000 Revised: April 5, 2010, Introduction This chapter describes how to set up and connect the cables, microphone and Cisco Unified

More information

TITLE: FIBER OPTIC SHOCK FIXTURES

TITLE: FIBER OPTIC SHOCK FIXTURES ENGINEERING PRACTICE STUDY TITLE: FIBER OPTIC SHOCK FIXTURES 18 January 2007 STUDY PROJECT 60GP-2006-019 FINAL REPORT Study Conducted By Dave Leight DSCC-VAT Fiber Optic Group Prepared by: Dave Leight

More information

Industrial Monitor Update Kit

Industrial Monitor Update Kit Industrial Monitor Update Kit (Bulletin Number 6157) Installation Instructions 2 Table of Contents Table of Contents Industrial Monitor Update Kit... 3 Overview... 3 Part 1 - Initial Preparation... 5 Part

More information

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber

More information

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N 24 Address Point Fibre distribution point (FDP) Installation guide for fibre DP Contents 1 Kit Contents 2 Accessories 3 MOBRA installation

More information

Compact Module. Category 6 FTP Cabling System

Compact Module. Category 6 FTP Cabling System Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with

More information

Single sensor setup with NIVEL210

Single sensor setup with NIVEL210 Single sensor setup with NIVEL210 Essential Items: 576 198 NIVEL210 RS232 748 335 Cable, Lemo 0 power supply cable Lemo 1 802 902 Cable, Lemo 0 722 409 Power supply plus power cords 802 902 576 198 748

More information

Optical Distribution Box 300 Installation Guide. Version : R0.0

Optical Distribution Box 300 Installation Guide. Version : R0.0 Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be

More information

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY 06.18.18 BEFORE YOU BEGIN Determine your light bar mounting method. Are you using pre-existing sockets to mount? If so, Retrofit Connectors are included. If not, be sure to purchase our Speed Spring Brackets

More information

Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Cable transit device Roxtec RS ES Ex General information Installation and maintenance: For European member countries of GENELEC, shall standard EN 60079-14 and EN 60079-17 be considered. For countries members of IECEx shall standard IEC 60079-14

More information

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E. www.wampfler.com Page 1 of 27 Index Page 1 Basics...4 2 Basic understanding of an IPT -system...5 3 General rules regarding metal parts in close proximity...6 3.1 Envelope free of ferromagnetic material...6

More information

MRX1 1. Getting to know your MRX1 wireless controller

MRX1 1. Getting to know your MRX1 wireless controller Please read this guide carefully and retain for future use and maintenance. MRX1 1. Getting to know your MRX1 wireless controller Multizone Wireless Controller Installation and User Guide The MRX1 Multizone

More information

Coyote popup display set up instructions

Coyote popup display set up instructions Coyote popup display set up instructions Frame 1 2 3 Prepare frame for assembly by locating the purple hooks on top of the frame. Stretch frame to size, snapping magnetic locking arms together. Attach

More information

Instructions. Cable with Armor F CAUTION. October Rev A

Instructions. Cable with Armor F CAUTION. October Rev A 3M Single Conductor Accessory Breakout Kits (BOK's) for use with 3M Cable Accessories (Terminations, T-Bodies and Push-On Elbows) For Use With Single Conductor Accessories On Three-Core Conductor Cables

More information

Assembly instructions

Assembly instructions Assembly instructions Model: MXR0024/KIT TV Aerial - 18 Element Kit Contact: Helpline: +44 (0)1553 811000 Email: support@maxview.co.uk Web: www.maxview.co.uk Maxview reserve the right to change specifications

More information

Connectivity accessories by Nestor Cables

Connectivity accessories by Nestor Cables Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com

More information

PRODUCT DESCRIPTION N3S

PRODUCT DESCRIPTION N3S PRODUCT DESCRIPTION N3S Nexans N3S ODF system NEXANS N3S ODF SYSTEM Contents Contents Systems description Patching frame Splice frame Patching module (KB 104/109) Splicing module Accessories Page 2 Page

More information

Section Communications Optical Fiber Backbone Cabling

Section Communications Optical Fiber Backbone Cabling Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related

More information

LCS2 Cat. 6 RJ 45 Patch panels and units

LCS2 Cat. 6 RJ 45 Patch panels and units 87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2

More information

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs INUCION MANUAL NPPA-- PACH PANEL Easy Patch 96 Bantam () Jacks, older lugs NEUIK AG NEUIK Zürich AG NEUIK (UK) Ltd. NEUIK UA INC. NEUIK okyo Ltd. NEUIK France NEUIK Vertriebs GmbH Liechtenstein witzerland

More information

Bionic Elephant Trunk. Assembly Instructions

Bionic Elephant Trunk. Assembly Instructions Bionic Elephant Trunk Assembly Instructions Equipment and Supplies Required items from the Bionics Kit and/or Materials Pack: 1. Tail fin (small) assembled 2 see Start Here for tail fin assembly instructions

More information

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION 1.2 - ORIGINAL ASSEMBLY GUIDE It is important to read this assembly guide before using the Dreamoc Diamond, and to follow advices and instructions on safety,

More information

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR CANNON STANDARD page 1 of 18 1 General Information... 2 1.1 Scope... 2 2 Ordering Code... 3 2.1 Housing / Motor Side... 3 2.2 Cable Side... 3 3 Explosion Drawing... 3.1 Explosion Complete Assembly... 3.2

More information

Structured Cabling Introduction & Installation Guide

Structured Cabling Introduction & Installation Guide Structured Cabling Introduction & Installation Guide Structured Cabling Overview General Structure - Cat5e/Cat6 Cabling The structure illustrated has the following key points: Face plates present outlet

More information

PATCH PANEL Easy Patch INSTRUCTION MANUAL

PATCH PANEL Easy Patch INSTRUCTION MANUAL Page 1 BDA82-0 PATCH PANEL Easy Patch 96 Bantam (TT) Jacks 50 pin D-subminiature NPPA-TT-SD50 Easy Patch NPPA-TT-SD50 Page 2 BDA82-0 Index page 1 Electrical configuration 3 2 Re-Configuration and Replacement

More information

Service Parts Diagrams. For Model: 10/20/09 Service Parts Diagrams for the Rear Projection SMART Board 3000i-DV Interactive Whiteboard 1

Service Parts Diagrams. For Model: 10/20/09 Service Parts Diagrams for the Rear Projection SMART Board 3000i-DV Interactive Whiteboard 1 Service Parts Diagrams For Model: 000i-DV with the serial NEC MT060 numbers Serial greater numbers than 000 000i-DV-09000 to 0999 0/0/09 Service Parts Diagrams for the Rear Projection SMART Board 000i-DV

More information

Gel-sealed in-line fiber optic closure

Gel-sealed in-line fiber optic closure SCIL-C Gel donut INSTALLATION INSTRUCTION TC-1363-1-IP Rev A, Oct 2017 www.commscope.com Gel-sealed in-line fiber optic closure Contents 1 General 2 Sizing and product kit information 3 Installation conditions

More information

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

A. All communications equipment rooms shall be installed in a neat and workmanlike manner. SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information