PINMRF. Checkout Quiz - Varian Inova-300 Version

Size: px
Start display at page:

Download "PINMRF. Checkout Quiz - Varian Inova-300 Version"

Transcription

1 PINMRF Checkout Quiz - Varian Inova-300 Version Please carefully read every question and select the best answer(s). Some questions may have more than one correct answer. You must select all the correct answers to receive credit. You must answer at least 28 questions correctly to pass (ca. 80 %). This is an open-book quiz. You may use any training materials and notes that you have. You have 30 minutes to complete this exam. Name: Group: Date: Trained by: Signature: By signing above you certify that you will abide by the PINMRF rules and regulations, and that you have understood the safety-related material that has been presented to you : Update - JSH : Update - JSH : First release JSH

2 1. Which of the following lock functions need to be optimized before locking your sample? A. Field and lock gain. B. Sweep rate, lock gain and lock power. C. Shims, lock gain and lock phase. D. Field, lock gain, and lock phase. E. None of them relevant lock functions are set by using the correct h1xxxx command. 2. Which of the following lock functions may need to be optimized after locking your sample? A. Spin rate and lock gain. B. Lock gain and lock power. C. Lock gain and lock phase. D. Field and lock gain. E. None of them you should never adjust any lock function, period. 3. When should you adjust the lock phase? A. Never. B. When the lock level is too low. C. When the lock level is too high. D. When the shimming is poor. E. When you are bored. 4. NMR samples are spun for what purpose? A. To obtain a uniform mixture of solute and the solvent. B. To obtain a lock signal. C. To bring the signal on resonance with the transmitter frequency. D. To obtain a more uniform average magnetic field over the sample volume and therefore lower resolution and sensitivity. E. To obtain a more uniform average magnetic field over the sample volume and therefore higher resolution and sensitivity. 5. If your sample will not spin properly, what should you do? A. Increase the spin rate setting. B. Eject and re-insert the sample several times to clean out the system. C. Run your experiment without spinning if the locking and shimming are OK. D. Remove your sample and transfer the solution to another NMR tube. E. Turn up the air pressure using the regulator close to the spectrometer. F. Check the spinning using the lock standard sample if it is still not good, notify PINMRF staff. 1

3 6. If your sample tube breaks with all or part of the tube in the NMR magnet, what should you do? A. Pick up any glass outside the magnet, hide the spinner, and leave the lab as quickly as possible. B. Remove the probe from the magnet, and then clean out the glass from the probe. C. Put a note on the spectrometer that a sample is broken in the magnet. D. Notify PINMRF staff that a sample has broken, giving details of the sample composition. E. Turn up the air pressure, using the regulator close to the spectrometer, to blow out any glass. 7. On the PINMRF Varian Inova-300 spectrometers, what do the following commands mean? nt wft ga print rt rts standard aph zg exit 8. The term FID stands for A. Fourier transformed Induced Decay B. Free Induction Decay C. Free Incoherent Decoupling D. Fourier Inductance Decay E Ferrous Incoherent Device 9. For PINMRF's 300 & 400 MHz spectrometers, how many 15-minute blocks of NMR time between the hours of 9:00 a.m to 5:00 p.m. may an individual reserve using the written sign-up sheets? A. One per day B. Two per day C. Four per day C. As many as you like, any day 2

4 10. Which of the following statements are true regarding the saving and storage of NMR data? A. You are allowed to save NMR data on the PINMRF Varian spectrometers. B. You are NOT allowed to save NMR data on the PINMRF Varian spectrometers. C. PINMRF staff will archive your saved NMR for you. D. PINMRF staff will NOT archive your saved NMR for you. 11. When saving NMR data files, which of the following regarding naming files is correct? A. you can use any characters in the filename, up to 80 characters. B. you can use letters and numbers and the space bar in the filename. C. you can use letters and numbers and the dash and the underscore in the filename. D. you must not use capital letters as part of the filename. 12. The signal-to-noise ratio of a spectrum is proportional to the square root of the number of scans acquired. Therefore, if you have run a 13 C experiment for four hours, and would like to increase the existing signal-to-noise ratio by a factor of two, how much longer will you need to acquire data for? A. four hours. B. eight hours. C. twelve hours. D. sixteen hours. 13. If the volume of your sample is ca. 500ul (not the standard ul) which of the following figures below represents the correct sample position in the sample depth gauge? A. B. C. D. 3

5 14. What benefit(s) are obtained by using the sample depth gauge to center the sample volume in the probe coil? A. It puts the sample in the most homogeneous magnetic field, which improves lineshape. B. The sample will spin more easily due to its mass centered around the coil. C. Sensitivity is improved because the most sample is within the probe coil. D. The z shims have been optimized for this position of the sample, so shimming is easier. E. B and D only. F. A and C only. G. A, C and D. H. A, B, C and D. 15. When running more than one sample on a Varian spectrometer, you must A. tune, match, and shim every sample. B. spin, calibrate the pulse width, and lock every sample. C. lock and shim every sample. D. use the depth gauge, lock, and shim every sample. E. be very patient. 16. Safety regulations prohibit persons with pacemakers or magnetic objects inside the line of a superconducting magnet. A. 50 Gauss B. 10 Gauss C. 5 Gauss D. 2 Gauss E. 1 Gauss 17. Any user-specific parameters can be changed A before the standard parameters have been read. B. after the standard parameters have been read. C. never parameters should not be changed. D. none of the above. 18. Which of the following statements are correct regarding probe tuning on the PINRMF Varian Inova-300 NMR Spectrometers? A. The user must always tune the probe for every sample. B. The user does not need to tune the probe when running 1 H, 19 F, 31 P or 13 C experiments. C. The user does need to tune the probe for nuclei other than 1 H, 19 F, 31 P or 13 C. D. Probe tuning on the Varian requires additional training. E. 11 B spectra can be obtained on the Inova spectrometer (4100 BRWN) without having to tune the probe. F. All choices except A are correct. 4

6 19. In order to autophase your spectrum, type A. apk. B. aph. C. phase. D. you must always manually phase your spectrum. 20. What is the proper method to insert the sample tube into the spinner? A. Hold the large end of the spinner in your hand and push the sample tube into the small end of the spinner. B. Hold the small end of the spinner in your hand and push the sample tube into the large end of the spinner. C. Put the spinner in the depth gauge and push the sample tube into the large end of the spinner. D. Hold the large end of the spinner in your hand and push the sample tube into the large end of the spinner. 21. The PINMRF Varian Inova-300 s do have sample-temperature controllers. This statement is A. TRUE. B. FALSE. 22. NEVER place an empty spinner into the bore of the magnet! This statement is A. TRUE. B. FALSE. 23. NEVER lean against or push on the magnet! This statement is A. TRUE. B. FALSE. 24. On the PINMRF Varian spectrometers, the sample temperature controller should normally be off. This statement is A. TRUE. B. FALSE. 25. When leaving the spectrometer, you should A. click on exit and log out. B. click on exit. C. click on eject and terminate and then insert and lock standard sample. D. insert the lock sample, issue the standard command, exit VNMR, then log out. 5

7 26. When is it acceptable for you to take metal objects near the magnet? A. When there is no sample in the magnet. B. When there is no experiment running. C. When the metal objects are small, such as paper clips or staples. D. When no-one else is around. E. When you want to show your friends how powerful the magnet is. F. Never. 27. In case of an emergency, where are the contact names and phone numbers listed? A. On a bulletin board or other vertical surface readily seen when sitting at the computer. B. On the desk by the phone. C. On the desk by the computer. D. On the wall directly above the computer. 28. Which NMR experiments in the list below require additional training from PINMRF staff before you are allowed to run them on the PINMRF Varian spectrometers? A. Low-temperature VT. B. The 13 C DEPT experiment. C. Any experiment involving nuclei other than 1 H, 19 F, 31 P, 13 C or 11 B (300-2, 4100 BRWN). D. A and C. 29. If your NMR tube fits very loosely in the sample spinner, what should you do? A. Stick a piece of Kimwipe or other paper into the spinner to help hold the sample. B. Remove the rubber o-ring from the spinner. C. Put your NMR sample into a new tube that fits correctly. D. Check the fit of the lock standard sample if it is loose too, notify PINRMF staff. 30. If your lock signal is unstable (it fluctuates to higher and lower levels) what should you do to correct this? A. Stop your work immediately and notify PINMRF staff. B. Eject your sample and restart the process again. C. Decrease the lock gain. D. Decrease the lock power. 6

8 31. Which 2D NMR experiment(s) are set up for you to run on the Varian Inova-300 s using standard parameter sets? A. COSY. B. TOCSY. C. HMQC / HMBC. D. HETCOR. E. All of the above. F. A and D. 32. If an NMR magnet quenches while you are running an experiment, what should you do? A. Run out of the lab as fast as you can and then set off the nearest fire alarm. B. Stop your experiment and remove your sample from the magnet, then notify PINMRF staff. C. Open the lab windows and doors, cover the magnet, then notify PINMRF staff. D. Leave the lab immediately, crawling close to the floor if necessary, then notify PINMRF staff. E. Notify PINMRF staff, then wait until the vapor clears to continue your experiment. F. Call 911 from the lab phone and then run out of the lab as fast as you can. 33. You are running a 1 H NMR experiment and you notice that the peaks in your spectrum are broad and have an extra splitting on the upfield side. Which of the following are possible source(s) of the problem? A. The shims are not optimized. B. The probe tuning is poor. C. You loaded the wrong parameter set. D. The sample is not spinning. E. The sample volume is too small. F. The sample temperature controller is set to 323K. 34. You are trying to print out your spectrum but the printer is not responding. Which of the following activities are reasonable for you to attempt regarding the problem? A. Check that the printer has paper if not, you may reload the printer. B. Execute the plot command approximately 20 times to force the printout to appear. C. Turn off the printer s power, wait one minute, then power up the printer again. D. Turn off the power to the spectrometer computer. E. Notify PINMRF staff. 7

9 35. Which of the following represents an ON-resonance deuterium lock signal for a single deuterated solvent with one deuterium resonance? A. D. B. E. C. F. A B C D E F 36. In order to monitor the sample temperature, which command will open the temperature control window? A. two (temperature window open) B. edtemp C. edte D. temp 8

IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface)

IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface) IMSERC NMR MANUAL 05: Manual Operation of Agilent NMR Spectrometers (Chem350 Interface) Last updated: October 12, 2011 by Josh Kurutz THIS PAGE = QUICK START GUIDE 0) At the computer, make sure VNMRJ is

More information

Vnmrj Training Guide. Vnmrj overview

Vnmrj Training Guide. Vnmrj overview Vnmrj Training Guide Eugenio Alvarado. Department of Chemistry, University of Michigan. 10/29/10, 05/05/11 This manual describes the most basic operation of our Varian NMR spectrometers with Vnmrj 2.2D

More information

Procedure for Acquiring 2D Inverse Detection Spectra HMQC, HMBC and HSQC

Procedure for Acquiring 2D Inverse Detection Spectra HMQC, HMBC and HSQC Procedure for Acquiring 2D Inverse Detection Spectra HMQC, HMBC and HSQC This protocol is for qualified users operating Bruker Avance 400 in IBC only. Dr. Jao STOP accepts no responsibility for actions

More information

1 H HOMODECOUPLING EXPERIMENT

1 H HOMODECOUPLING EXPERIMENT 1 H HOMODECOUPLING EXPERIMENT This is a simple and quick means of determining if two resonances are coupled. The HOMODEC experiment is most effective for relatively simple spectra where the couplings are,

More information

Basic 13 C Acquisition and Processing 4

Basic 13 C Acquisition and Processing 4 Chapter Basic 13 C Acquisition and Processing 4 Goto Introduction 4.1 This chapter describes the acquisition and processing of a 13 C spectrum acquired with a simple one-pulse sequence with and without

More information

UCI NMR MANUAL DRX400 GN500 CRYO500 AVANCE600

UCI NMR MANUAL DRX400 GN500 CRYO500 AVANCE600 UCI NMR MANUAL DRX400 GN500 CRYO500 AVANCE600 Please do not attempt to print this manual directly from the NMR workstations. To obtain or print your own copy, please either ask the NMR facility director

More information

NMR. picospin. Maintenance Guide

NMR. picospin. Maintenance Guide NMR picospin Maintenance Guide 269-302600 Revision A January 2013 2013 Thermo Fisher Scientific Inc. All rights reserved. For U.S. Technical Support, please contact: Thermo Fisher Scientific 5225 Verona

More information

Introduction to 1D & 2D NMR using VnmrJ

Introduction to 1D & 2D NMR using VnmrJ Introduction to 1D & 2D NMR using VnmrJ Scott R. Burt September 12, 2011 This document is an introductory tutorial for collecting the most important NMR spectra in organic chemistry: (1D) 1 H, 13 C, NOESY,

More information

MestReNova Manual for Chem 201/202. October, 2015.

MestReNova Manual for Chem 201/202. October, 2015. 1. Introduction to 1-D NMR Data Processing with MestReNova The MestReNova program can do all of the routine NMR data processing needed for Chem 201 and 202 and will be available through the Reed downloads

More information

Practicum 3, Fall 2010

Practicum 3, Fall 2010 A. F. Miller 2010 T1 Measurement 1 Practicum 3, Fall 2010 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z magnetization

More information

MestReNova A quick Guide. Adjust signal intensity Use scroll wheel. Zoomen Z

MestReNova A quick Guide. Adjust signal intensity Use scroll wheel. Zoomen Z MestReNova A quick Guide page 1 MNova is a program to analyze 1D- and 2D NMR data. Start of MNova Start All Programs Chemie NMR MNova The MNova Menu 1. 2. Create expanded regions Adjust signal intensity

More information

Practicum 3, Fall 2012

Practicum 3, Fall 2012 A.- F. Miller 2012 T1&T2 Measurement 1 Practicum 3, Fall 2012 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z- magnetization,

More information

cyclenoe 1D NOE Difference Experiment

cyclenoe 1D NOE Difference Experiment cyclenoe 1D NOE Difference Experiment NOTE: If you are interested in qualitative or long-range NOE s, you should use the NOESY1D experiment (see NOESY1D handout for experimental details). However, you

More information

Fall 2014 Chem 636 Lab #4

Fall 2014 Chem 636 Lab #4 latest update: 140922 (cgf) Fall 2014 Chem 636 Lab #4 Assignment due at beginning of lab, week 5 (Sept 30 Oct 2). Use Athena (AC-300) for section I, and Persephone (AVANCE-500) for Sections II and III.

More information

Processing data with Mestrelab Mnova

Processing data with Mestrelab Mnova Processing data with Mestrelab Mnova This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and

More information

NMR TRAINING MANUAL LINUX-BASED SPECTROMETERS. And VnmrJ 2.x TEXAS A&M UNIVERSITY DEPARTMENT OF CHEMISTRY

NMR TRAINING MANUAL LINUX-BASED SPECTROMETERS. And VnmrJ 2.x TEXAS A&M UNIVERSITY DEPARTMENT OF CHEMISTRY NMR TRAINING MANUAL LINUX-BASED SPECTROMETERS And VnmrJ 2.x TEXAS A&M UNIVERSITY DEPARTMENT OF CHEMISTRY November 9, 2009 TABLE OF CONTENTS 1. OVERVIEW 1 1.1 WHAT IS FTNMR? 1 1.2 MULTITASKING 1 1.3 DUAL

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions Note: Enter your complete name, CMRF user code, and date into the record book. You must have previously filled out a project information

More information

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area. BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features

More information

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer solvents) Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml

More information

KJM Organic NMR Spectroscopy. Laboratory Experiments - part 1

KJM Organic NMR Spectroscopy. Laboratory Experiments - part 1 KJM5250 - Organic NMR Spectroscopy 1 Laboratory Experiments - part 1 Pulse width, T1, Decoupling, DEPT, NOE Difference Spectroscopy (Xwinnmr on PC, version 3.5) on DPX 200 and DPX 300 Department of Chemistry

More information

User Manual OVP Raman

User Manual OVP Raman Version 6 User Manual OVP Raman 2006 BRUKER OPTIK GmbH, Rudolf-Plank-Straße 27, D-76275 Ettlingen, www.brukeroptics.com All rights reserved. No part of this manual may be reproduced or transmitted in any

More information

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode) 1. Log into the Log Usage system on the SMIF web site 2. Open Nanoscope 6.14r1 software by double clicking on the Nanoscope 6.14r1 desktop

More information

New Filling Pattern for SLS-FEMTO

New Filling Pattern for SLS-FEMTO SLS-TME-TA-2009-0317 July 14, 2009 New Filling Pattern for SLS-FEMTO Natalia Prado de Abreu, Paul Beaud, Gerhard Ingold and Andreas Streun Paul Scherrer Institut, CH-5232 Villigen PSI, Switzerland A new

More information

Vivat Prodigy? Juraj Bella. Core capability for Chemistry Research EPSRC & The University of Edinburgh

Vivat Prodigy? Juraj Bella. Core capability for Chemistry Research EPSRC & The University of Edinburgh Vivat Prodigy? Juraj Bella Core capability for Chemistry Research EPSRC & The University of Edinburgh 500 & 400 MHz nitrogen cooled cryoprobes 500 installed in Dec 2013 used from Jan 2014 400 installed

More information

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0 CHEM 411L Instrumental Analysis Laboratory Revision 2.0 Noise In this laboratory exercise we will determine the Signal-to-Noise (S/N) ratio for an IR spectrum of Air using a Thermo Nicolet Avatar 360 Fourier

More information

Classical simulations with PJNMR BCMB/CHEM LAB 01/25/12

Classical simulations with PJNMR BCMB/CHEM LAB 01/25/12 Classical simulations with PJNMR BCMB/CHEM LAB 01/25/12 The program PJNMR was written by Paul- Jean Letourneau as a joint project between the PENCE & NANUC projects in Canada. It rotates vectors representing

More information

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis

More information

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003 Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003 1. Generate mixed-valent state of compound check in 1mm cell. Ideally want Abs 1. 2. Setting up the instrument New Dewar i) Approx.

More information

Troubleshooting Guide. Prep, Scan Errors, and Artifacts

Troubleshooting Guide. Prep, Scan Errors, and Artifacts Troubleshooting Guide Prep, Scan Errors, and Artifacts Preparing for the Study Participant Compliance with MRI Scans Participant Prep Having your participant prepped will allow you to run your study with

More information

Quick Start Bruker Dimension Icon AFM

Quick Start Bruker Dimension Icon AFM Do not remove Quick Start Bruker Dimension Icon AFM March 3, 2015 GLA Contacts Harold Fu (hfu@caltech.edu) Weilai Yu (wyyu@caltech.edu) Bruker Tech Support (AFMSupport@bruker-nano.com 800-873-9750) Watch

More information

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

Standard Operating Procedure II: EDS (Bruker Flat-Quad) Standard Operating Procedure II: EDS (Bruker Flat-Quad) ywcmatsci.yale.edu ESC II, Room A119F 810 West Campus Drive West Haven, CT 06516 Version 1.1, October 2018 1 > FOLLOW the SOP strictly to keep the

More information

Guide to the 600 and 800 Note means enter key

Guide to the 600 and 800 Note means enter key Guide to the 600 and 800 Note means enter key 1. Check that no one else is already using the spectrometer! a. Is the Fid Flash panel flashing? b. Does the Acquisition Information panel says no acquisition

More information

SigPlay User s Guide

SigPlay User s Guide SigPlay User s Guide . . SigPlay32 User's Guide? Version 3.4 Copyright? 2001 TDT. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or

More information

KJM Organic NMR- Spectroscopy. Laboratory Experiments - part 1

KJM Organic NMR- Spectroscopy. Laboratory Experiments - part 1 KJM5250 - Organic NMR- Spectroscopy 1 Laboratory Experiments - part 1 Pulse width determination, T 1 relaxation time constant measurement, 1 H- 1 H Decoupling, noe Difference Spectroscopy, DEPT. (Xwinnmr

More information

Approved by: / / R. Battaglia 12/16/2016

Approved by: / / R. Battaglia 12/16/2016 Fabrication Laboratory Revision: H Rev Date: 12/16/16 Approved by: Process Engineer / / R. Battaglia 12/16/2016 Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Varian

More information

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY Standard Operating Procedure for the Bruker X8 APEX II Single-Crystal X- Ray Diffractometer Contact Manager: Dr. Cassie Ward ward@wayne.edu Office room 061 Chemistry (313) 577-2587 LIC Lab: (313) 577-0518

More information

NMR picospin User Guide

NMR picospin User Guide NMR picospin User Guide Software Version 0.9.0 269-298002 Revision A June 2014 2013-2014 Thermo Fisher Scientific Inc. All rights reserved. For U.S. Technical Support, please contact: Unity Lab Services

More information

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5 Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5 Lecture Capture Setup... 6 Pause and Resume... 6 Considerations... 6 Video Conferencing Setup... 7 Camera Control... 8 Preview

More information

ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER!

ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER! ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER! Analyze for moisture/solids with SMART Turbo 1 Roll sample and place in Trac Tube 2 Insert into NMR chamber for analysis 3 Precise results in 8

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications R&S RT-Zxx High-Voltage and Current Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZH10/-ZH11 high-voltage probes... 5 R&S RT-ZD01

More information

Procedures for conducting User QA on the scanner

Procedures for conducting User QA on the scanner Procedures for conducting User QA on the scanner Sample setup: The User QA phantom is clearly labeled and is stored on one of the shelves to the side of the magnet. Note proper orientation of the bottle,

More information

HD Review March 30, 2011 Franz Klein

HD Review March 30, 2011 Franz Klein HD Review March 30, 2011 Franz Klein !! Circularly & linearly polarized photon beam on longitudinally polarized target Circularly polar. photon via helicity transfer from 92 calendar days Linearly polar.

More information

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V. 1234 Hach Hall 515-294-5805 www.cif.iastate.edu Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V. Location: Contact: 1238 Hach Hall Steve Veysey, 1234 Hach Hall; Kamel Harrata,

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

CONTROLS AND CONNECTIONS - figs. 1 & 2

CONTROLS AND CONNECTIONS - figs. 1 & 2 Scanned, ocr ed and converted to PDF by HansO, 2001 CONTROLS AND CONNECTIONS - figs. 1 & 2 (1) tape counter with zero reset button (2) SAVE indicator - lights up during data saving (3)DATA FLOW indicator

More information

Chem 203 December 20, Final Exam Part II Problem 1 of 3 (30 points)

Chem 203 December 20, Final Exam Part II Problem 1 of 3 (30 points) Name: Chem 203 December 20, 2014 Final Exam Part II Problem 1 of 3 (30 points) Select and submit TWO OUT OF THE THREE PROBLEMS FROM PART II for grading. Do not submit three problems. If you wish to unstaple

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

Tips and Tricks Part-II: Bits and pieces

Tips and Tricks Part-II: Bits and pieces Tips and Tricks Part-II: Bits and pieces Clemens Anklin Pittsburgh April 2016 Innovation with Integrity Overview 1H -13C correlation experiments Which ones to choose and a few pitfalls. Non-uniform or

More information

MRI Training for Scanning at the VA

MRI Training for Scanning at the VA MRI Training for Scanning at the VA Acquiring permission to scan is straightforward at the VA Boston Neuro- Imaging Center and requires careful following through a series of steps listed below. No one

More information

Selection Table. Ordering Information

Selection Table.  Ordering Information Selection Table Fluke 199 Fluke 196 Fluke 192 Fluke 123 Bandwidth 200 MHz 100 MHz 60 MHz 20 MHz Max. real-time sample rate 2.5 GS/s 1 GS/s 500 MS/s 25 MS/s Inputs and digitizers 2 plus external / DMM input

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

Oscilloscopes for field applications

Oscilloscopes for field applications Oscilloscopes for field applications ScopeMeter 123 and 190 Series 20 MHz to 200 MHz bandwidth Up to 2.5 GS/s real-time sampling Up to 5 hours battery operating time Easy to use with Connect-and-View triggering

More information

ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER!

ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER! ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER! Analyze for moisture/solids with SMART Turbo 1 Roll sample and place in Trac Tube 2 Insert into NMR chamber for analysis 3 Precise results in 8

More information

Activity P32: Variation of Light Intensity (Light Sensor)

Activity P32: Variation of Light Intensity (Light Sensor) Activity P32: Variation of Light Intensity (Light Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Illuminance P32 Vary Light.DS P54 Light Bulb Intensity P54_BULB.SWS Equipment Needed

More information

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy D. Johnson, R. Westerman, M. DeVre, Y. Lee, J. Sasserath Unaxis USA, Inc. 10050 16 th Street North

More information

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework 1.0 Purpose This technical procedure shall be followed for the operation of the Scanning

More information

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. Multichannel Scaler Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. The ideal solution for: Time-resolved single-photon counting Phosphorescence lifetime spectrometry Atmospheric and

More information

LedSet User s Manual V Official website: 1 /

LedSet User s Manual V Official website:   1 / LedSet User s Manual V2.6.1 1 / 42 20171123 Contents 1. Interface... 3 1.1. Option Menu... 4 1.1.1. Screen Configuration... 4 1.1.1.1. Instruction to Sender/ Receiver/ Display Connection... 4 1.1.1.2.

More information

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes: PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties Due Thursday, 2 Nov 2017 For this lab, you will explore the properties of the working HeNe laser. 1. Observation of higher-order modes: Realign

More information

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential

More information

COLOR TFT LCD MONITOR. Manual

COLOR TFT LCD MONITOR. Manual COLOR TFT LCD MONITOR Manual Safety defended: Properly maintains your system to be possible to guarantee its service life and to reduce the damage risk. It should avoid the damp and exceeding temperature

More information

800 Displaying Series Flowmeter

800 Displaying Series Flowmeter TECHNICAL PRODUCT INSTRUCTION SHEET 800 Displaying Series Flowmeter OVERVIEW The principle of operation is very simple. A jet of liquid is directed at a free running Pelton wheel turbine in a specially

More information

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple

More information

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System 7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key

More information

TIME RESOLVED XAS DATA COLLECTION WITH AN XIA DXP-4T SPECTROMETER

TIME RESOLVED XAS DATA COLLECTION WITH AN XIA DXP-4T SPECTROMETER TIME RESOLVED XAS DATA COLLECTION WITH AN XIA DXP-4T SPECTROMETER W.K. WARBURTON, B. HUBBARD & C. ZHOU X-ray strumentation Associates 2513 Charleston Road, STE 207, Mountain View, CA 94043 USA C. BOOTH

More information

Electrical connection

Electrical connection Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS USER MANUAL 27 Full HD Widescreen LED Monitor L27ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 22 Class Slim HD Widescreen Monitor L215DS USER MANUAL 22" Class Slim HD Widescreen Monitor L215DS TABLE OF CONTENTS 1 Getting Started Package Includes Installation 2 Control Panel / Back Panel Control Panel Back Panel 3 On Screen Display 4 Technical

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum

More information

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR Introduction: The RMA package is a PC-based system which operates with PUMA and COUGAR hardware to

More information

DVR-431 USB Wireless Receiver User Manual

DVR-431 USB Wireless Receiver User Manual DVR-431 USB Wireless Receiver User Manual Thank you for using our wireless USB receiver, please read the following content carefully before using, it will help you make better use of this product. Introduction

More information

Chem 203 December 20, Final Exam Part II Problem 2 of 3 (30 points)

Chem 203 December 20, Final Exam Part II Problem 2 of 3 (30 points) Chem 203 December 20, 2014 Final Exam Part II Problem 2 of 3 (30 points) Name: Select and submit TWO OUT OF THE THREE PROBLEMS FROM PART II for grading. Do not submit three problems. If you wish to unstaple

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

TT AFM LongBeach Procedures and Protocols V2.1

TT AFM LongBeach Procedures and Protocols V2.1 TT AFM LongBeach Procedures and Protocols V2.1 1. Startup Procedure 1. Turn on PC: Allow to boot to Windows. Turn on monitor. Password is afm 2. Turn on second PC that controls the video camera. 3. Turn

More information

Broadcast Television Measurements

Broadcast Television Measurements Broadcast Television Measurements Data Sheet Broadcast Transmitter Testing with the Agilent 85724A and 8590E-Series Spectrum Analyzers RF and Video Measurements... at the Touch of a Button Installing,

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City 21 March 2007 070315 - dk v5 - Ovasen Case Study Written by David Kotch Edited by John Storyk A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City 1. Overview - Description of Problem

More information

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City 21 March 2007 070315 - dk v5 - Ovasen Case Study Written by David Kotch Edited by John Storyk A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City 1. Overview - Description of Problem

More information

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL COMPOSITE VIDEO METER MODEL VLM- COMPOSITE VIDEO METER MODEL VLM- NTSC TECHNICAL INSTRUCTION MANUAL VLM- NTSC TECHNICAL INSTRUCTION MANUAL INTRODUCTION EASY-TO-USE VIDEO LEVEL METER... SIMULTANEOUS DISPLAY...

More information

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University Introduction: Scanning Probe Microscopy (SPM) is a general term referring to surface characterization techniques that utilize

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

Lecture 17 Microwave Tubes: Part I

Lecture 17 Microwave Tubes: Part I Basic Building Blocks of Microwave Engineering Prof. Amitabha Bhattacharya Department of Electronics and Communication Engineering Indian Institute of Technology, Kharagpur Lecture 17 Microwave Tubes:

More information

Quadrupoles have become the most widely used

Quadrupoles have become the most widely used ARTICLES A Novel Tandem Quadrupole Mass Analyzer Zhaohui Du and D. J. Douglas Department of Chemistry, University of British Columbia, Vancouver, B. C., Canada A new tandem mass analyzer is described.

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

Linrad On-Screen Controls K1JT

Linrad On-Screen Controls K1JT Linrad On-Screen Controls K1JT Main (Startup) Menu A = Weak signal CW B = Normal CW C = Meteor scatter CW D = SSB E = FM F = AM G = QRSS CW H = TX test I = Soundcard test mode J = Analog hardware tune

More information

ENGR 1000, Introduction to Engineering Design

ENGR 1000, Introduction to Engineering Design Unit 2: Mechatronics ENGR 1000, Introduction to Engineering Design Lesson 2.3: Controlling Independent Systems Hardware: 12 VDC power supply Several lengths of wire NI-USB 6008 Device with USB cable Digital

More information

PSC300 Operation Manual

PSC300 Operation Manual PSC300 Operation Manual Version 9.10 General information Prior to any attempt to operate this Columbia PSC 300, operator should read and understand the complete operation of the cubing system. It is very

More information

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory Data Collection Using APEX3 Page 1 of 10 Data Collection Using APEX3 March 30, 2017 Chemical Crystallography Laboratory Author: Douglas R. Powell Data Collection Using APEX3 Page 2 of 10 Distribution Douglas

More information

OSCILLOSCOPE AND DIGITAL MULTIMETER

OSCILLOSCOPE AND DIGITAL MULTIMETER Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also

More information

ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals

ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals Purdue University: ECE438 - Digital Signal Processing with Applications 1 ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals October 6, 2010 1 Introduction It is often desired

More information

Results of the June 2000 NICMOS+NCS EMI Test

Results of the June 2000 NICMOS+NCS EMI Test Results of the June 2 NICMOS+NCS EMI Test S. T. Holfeltz & Torsten Böker September 28, 2 ABSTRACT We summarize the findings of the NICMOS+NCS EMI Tests conducted at Goddard Space Flight Center in June

More information

COLOR TFT LCD MONITOR. User Manual

COLOR TFT LCD MONITOR. User Manual COLOR TFT LCD MONITOR User Manual 0 GENERAL INFORMATION Thank you for choosing our TFT LCD (liquid crystal display) monitor. This product employs integrate circuits, low power consumption, and no radiation

More information

The FLASH objective: SASE between 60 and 13 nm

The FLASH objective: SASE between 60 and 13 nm Injector beam control studies winter 2006/07 talk from E. Vogel on work performed by W. Cichalewski, C. Gerth, W. Jalmuzna,W. Koprek, F. Löhl, D. Noelle, P. Pucyk, H. Schlarb, T. Traber, E. Vogel, FLASH

More information