Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing."

Transcription

1 Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital ma Max. outputs load Voltage: Zload > 1kΩ Analogue - Current: Zload < 600 Ω Reverse polarity protected Yes Short circuit protected Yes Inductive load protection - Yes Environmental Data Light incidence > lux Temperature, operation -30 to + 60 ºC Sealing class IP 67 Marking Available Models Model Beam spacing Sensing Range SST xxx-xxx-05-H-1D1-0.5-J5 5 mm Transmitter SST xxx-xxx-10-H-1D1-0.5-J5 10 mm 10 m SST xxx-xxx-20-H-1D1-0.5-J5 20 mm SSR xxx-xxx-05-H-UUK-ZZW--0.5-J12 5 mm Receiver SSR xxx-xxx-10-H-UUK-ZZW--0.5-J12 10 mm 0.5 m 10 m SSR xxx-xxx-20-H-UUK-ZZW--0.5-J12 20 mm Connection Wiring Diagrams 5 pin, M12 12 pin, M12 Installation & Adjustments Installation The light curtain is configured by the PC program Telco Space Scan Terminal, described in the following pages. Before using it, check the power supply complies with electrical data. 1 Mount the transmitter (SST) and receiver (SSR) facing each other and correctly aligned. 2 Wire the sensor according to the wiring diagram. Notice that the pin 2 on the SSR and the pin 3 on SST (blue wires) must be connected together to a common GND ( ). Make sure the SSR output load does not exceed 100 ma. 3 Check for correct wiring before turning power on. 4 5 When the power on indicator (green LED) on SSR and SST is on, the system is operating. The position of the receiver and transmitter must not be changed after power-up. The light curtain is only intended for static applications. SST Test Input The transmitter SST can be externally disabled and enabled via the black control wire for test purposes. When the transmitter is disabled the action of the receiver corresponds to breaking all beams. SSR Digital Input 1 The digital input can be used to switch between two different output readings on the analogue output. The time from a transition on the digital input to a transition on the analogue output is dependent on the number of beams. The maximum transition time can be calculated as 500us + the number of beams multiplied by 15us. Using cross beam scan mode will double the number of beams. While communication on the RS485 in ongoing, the transition time will be considerably longer. Indicators SSR Red LED Status indicator SSR Yellow LED Follows state of Digital Output 1 SSR & SST Green LED Power on indicator Troubleshooting Probable Reason 1. Symptom: Status indicator (Red LED) on SSR is constant on. Corrective Action SST has no power. Check supply and supply cable to the SST SST 5 pole M12 male connector SSR 12 pole M12 male connector SST & SSR white, grey and blue wires are not connected correctly. Connect the wires. Transmitter Model Black wire connected to ( - ) Black wire not connected Black wire connected to ( + ) SST xxx-xxx-xx-H-1D1-0.5-J5 not transmitting transmitting transmitting 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Severe electrical interference. Separate SSR and SST supply cable from high voltage cables. Severe ambient light. Cross talk from another light curtain or photo sensor Cross talk from a nearby HF strip light Swap position of SSR and SST. Swap position of SSR and SST. Swap position of SSR and SST or remove the strip light. 3. Symptom: Digital outputs do not response when IR beams are obstructed. One or more beams are blocked or the rails are out of sensing range. Remove obstruction or reduce the distance between the rails. The test input on SST is activated Remove SST pin 4 (black wire) from ground. Wiring diagram UUK-ZZW Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pink Yellow Black Green Red Violet AC2 - DN2 Dig. NPN Out 2 Dig. Input 1 Analog Out + Analog Out - - Dig. NPN Out 1 AC2 - DP2 Dig. PNP Out 2 Dig. Input 1 Analog Out + Analog Out - - Dig. PNP Out 1 ANN - DN4 Dig. NPN Out Dig. NPN Out 3 Dig. NPN Out 4 Dig. NPN Out 1 ANN - DP4 Dig. PNP Out Dig. PNP Out 3 Dig. PPN Out 4 Dig. PNP Out 1 - = Not used Type name: SSR xxx-xxx-xx-H-UUK-ZZW--0.5-J8. The letters UUK-ZZW determine the output configuration of the SSR 02. Outputs are not configured for simple detection of obstructions If needed factory reset the SSR using the System Information page in the PC program Telco Space Scan Terminal Output configurations Page 1 of 7

2 SSR02 and PC connection To setup or adjust a SS02 it is required to use the Telco Space Scan Terminal software together with an RS485 data link. 1. Start by selecting the RS485 Serial Port and Modbus Set Up and select the correct port to communicate with the SS02. If the port number is not known it is possible to press the Get Com Port Information. This will list all COM Ports used by the PC. (Full Com port details in Win7, WinXP only basic details are shown ). The RS485 BUS ADDRESS is default 127, but address can be changed in the menu Function -> System Information. 2. Next press Connect and wait a few seconds before the connection is active. Page 2 of 7

3 File menu RS485 Serial Port and Modbus Setup: See SSR02 and PC connection. Search for Telco light curtains on a Modbus. Used for finding and identifying the Modbus address(es) of one or more light curtains on the Modbus. For more info see below. Connect See SSR02 and PC connection. Load configuration Used to load a file that will configure all functions of the light curtain in one go. The information is stored in a previously saved configuration file in ASCII format. Save configuration Saves information about the current configuration of the light curtain. Colour Preference It is possible to set up to 7 different colours for the beams on the screen. Exit Exit and close the program. Language Language selection. File -> Search for Telco Light curtain on a Modbus Use this function to find the Modbus Address(es) of Telco Light curtains on a Modbus, if the address(es) are unknown. Functions menu Overview: For configuration of outputs and measurement functions and for reading output states. System Information: For basic system information and configuration of Modbus address. Status Messages: Status messages are logged and displayed by choosing this menu item. Each functions associated with each of these menu items will be described in detail the following. Functions -> Overview -> General Setup tab General Setup: Right side shows the light curtain and the beam pattern. Unbroken or made beams are indicated by green and broken beams by red. The light curtain is in the setup oriented with the cable entry in the bottom. Page 3 of 7

4 Scan Mode. Parallel or Cross beam selection. On cross beam mode, the number of actual beams are increased from N straight beams to (3*N)-2 beams giving a more dense beam pattern, with larger detection certainty. If objects are positioned in the centre, or close to the centre, between transmitter and receiver the measurement resolution is increased to the double, i.e. the crossed beam mode adds an additional virtual beam between each of the straight beams, in total N-1 extra virtual beams. When crossed beam mode is selected the number of beams is increased to (2*N)-1 in total, which therefore also will be the new maximum of the analogue output. Be aware that objects has to be taken out of the light curtain when switching from parallel beam mode into crossed beam mode when it is in automatic gain mode. The reason is that the gain of the crossed beams has to be initialised. Gain Control: In the Manual Gain it is possible to set the Manual Gain Level (a fixed gain level). In Automatic Gain mode it is possible to set the excess gain level. In both manual and automatic gain is it possible to set the Hysteresis level. Keep objects out of the light curtain when switching to automatic gain mode or when adjusting the excess gain level, because the initial setting of each beam requires information about signal strength for an unbroken beam. Operation Mode: It is set by choosing between Digital Output INV (digital output inverted) and Digital Output NOT INV (digital output not inverted) and possibly by check-selecting the Hole Detection. When the digital output is not inverted the logical value of all the digital outputs will correspond to the logical value of the Boolean expressions set up in the definition of the digital outputs. This means that when the Boolean expression is TRUE, the output will be HIGH/energized/activated and the corresponding LED indicator on this page (Digital Output 1, 2, 3, 4) will be yellow, as shown below. If Hole Detection is activated, the status of all beams will be individually inverted, that means that made beams are converted to broken beams (and inversely), whereby holes (unbroken beams ) will be perceived as objects obstructing beams for the following analysis. Blanking: It means to deactivate beams resulting one or more areas in the light curtain where the status of the beams are ignored. Blanking can either be setup by writing directly which beams to be blanked in the text box. Writing 12-16, 20 means that all beams starting from beam no 12 and ending with beam no.16, and beam no. 20 are blanked. When the blanking is written, it shall be transferred to the light curtain pressing the button Write to Light Curtain, whereby it becomes active. Blanked beams are marked blue as seen below. Beams can also be blanked by simply reading obstructed beams from the light curtain by pressing the button Measure From Light Curtain, whereby the obstructed and now blanked beams will be written in the text box. It is not necessary to press Write to Light Curtain for activating the blanking. Smoothing Function (Minimum Size of Coherent Area): The Smoothing Function ls the SSR to ignore objects which are smaller than a specific size. If the Smoothing Function is set to 3, any object that interrupts 3 or less adjacent beams will be ignored. Smoothing can be used, e.g., to ignore interference caused by wood chips while sawing a log. The effect is obtained by a pre-processing of the beams status where all groups of adjacent broken beams with less than or equal to 3 beams are substituted by made beams. This smoothing function is carried out after the hole detection pre-processing. Input and Output Status Activated/energised/logical high digital output is indicated by yellow; else the indicator will be grey. Digital Input 1 indicator: green for high input and grey for low input. Signal OK indicator: when the signal level is sufficient for stable operation of the light curtain the Signal OK indicator will be green. If the Signal OK indicator is off, the gain should be increased or distance between transmitter and receiver should be decreased. The Signal OK indicator will also go out if there is a loss of synchronisation between the SST02 and the SSR02. Analogue Output value shows the value of the Analogue output function that is chosen in the tab Analogue Output. The measurement unit is the beam number. This value will be scaled correspondingly in the analogue current output or in the analogue voltage output. If Crossed Beam Mode is selected the span of the output values will be doubled, reflecting the double resolution achieved (objects has to be positioned in the centre of the light curtain, see Scan Mode) Page 4 of 7

5 Functions -> Overview > Analogue output tab The figure below shows the window that appears when the Analogue Output tab is selected under Function->Overview. On this tab it is possible to define the operation of the analogue output i.e. the measurement on the beam pattern that is going to be performed. The tab contains a number of marked areas; Analogue Output, Analogue Output Function and Set Analogue output. Analogue Output: In this box it is possible to Enable Output and Disable Output. When the output is enabled it is possible to select between Current output (4-20mA)* and Voltage output (0-10V)* using the pull down box. *Referred to 0 Vdc, pin 8 green wire (Analogue Out - ) Analogue Output Function: The function of the analogue output depends on the setting of the control input on the receiver. If the Digital Input 1 is connected to + (high), the function selected in the pull down box next to Control input high is active. If the Digital Input 1 is connected to (i.e. low) or not connected (N.C.), the function selected in the pull down box next to Control input low (NC) will be active. The functions selectable in the two boxes are identical. Notice that the status of the Digital Input 1 can be read in the Input and Output Status field. Following function can be selected Measurement functions: DIS: Disabled output. Output is disabled, i.e. constantly de-energised. FBB: First Beam Blocked. Position of the first beam blocked. FBM: First Beam Made. Position of the first beam made. LBB: Last Beam Blocked. Position of the last beam blocked. LBM: Last Beam Made. Position of the last beam made. MBB: Middle Beam Blocked. Position of the (FBB+LBB)/2 rounded to nearest integer TBB: Total Beams Blocked. Total number of beams blocked. TBM: Total Beams Made. Total number of beams made. CBB: Contiguous Beams Blocked. Reads out the number of beams in the largest group of adjacent beams blocked. CBM: Contiguous Beams Made. Reads out the number of beams in the largest group of adjacent beams made. TRN: Number of Transitions. The number of transitions in the beam pattern between made beams and blocked beams. OD: Outside dimensions. Reads out LBB - FBB+1, corresponding to the size of a single object contained in the beam pattern, counted in beam breaks. ID: Inside dimensions. Reads out the count of beams made between first beam broken and last beam broken. This corresponds to the size of a hole in a single solid object in the light curtain. CFBB: Contiguous First Beam Blocked. Reads out the number of the first beam in the largest group of adjacent beams blocked. CLBB: Contiguous Last Beam Blocked. Reads out the number of the last beam in the largest group of adjacent beams blocked. Force Set Enable: Marking the checkbox Force Set Enable disables all measurements and enables the user to set the output value in the textbox next to Analogue Output Value. This function can be used for test and calibration purposes. Note: The beams are counted starting with one from the end of the cable entry. Note: Unintended use of pre-filtering, i.e. hole detection or Maximum Area of adjacent beams blocked set different from 0 can lead to unexpected results! If crossed beam setting is used, the effective beam number is increase by a factor of 2. Page 5 of 7

6 Functions -> Overview > Digital Output tabs The Digital Output 1 tab, selected under Function->Overview, it is possible to define the operation of Digital Output 1. If the light curtain is equipped with multiple digital outputs, the other outputs can be configured by using the other identical digital output tabs. The digital output tab contains 3 marked areas: Digital Output, Digital Output Function and Set Digital Output. Digital Output: To Enable Output and Disable Output. Digital Output Function: A digital output can read out only two values which are associated with the Boolean values true and false; the output is either high = true or low= false. The output value is the result of the evaluation of a Boolean expression, that here is set up using the two pull down-boxes and text input box. The first box contains the same list of functions as available under Analogue Output Function. The second box contains a list of comparison operators. The third box is used to type in a number. If the expression is true, the out will be high, and if the expression is false, the output will be low. Set Digital Output Marking the checkbox Force Set Enable disables the Digital Output Function and enables the user to set the digital output high by selecting Output Forced High or low by selecting Output Forced Low. The function is primarily intended for test purposes. Page 6 of 7

7 Functions -> System information System information contains the information displayed in the figure below. The MODBUS address can be modified using the Change MODBUS Address button. Functions -> Status Messages Selecting Functions -> Status messages makes the window below appears. Status messages and error messages are logged and displayed. The log can be cleared by pressing the button Clear Status Messages. Page 7 of 7

KNX Dimmer RGBW - User Manual

KNX Dimmer RGBW - User Manual KNX Dimmer RGBW - User Manual Item No.: LC-013-004 1. Product Description With the KNX Dimmer RGBW it is possible to control of RGBW, WW-CW LED or 4 independent channels with integrated KNX BCU. Simple

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Amplifier for fiber optics. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing Amplifier for fiber optics Dimensioned drawing with cable en 01-2012/09 50118006 up to 1050mm up to 270mm with M8 connector 10-30 V DC We reserve the right to make changes DS_LV463_en_50118006.fm wo, large,

More information

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx laser / / 2010 Operating instructions Through-beam sensor OJ5xx laser 70480 / 00 05 / 200 Contents Preliminary note. Symbols used 2 Safety instructions Functions and features 4 4 Installation 4 5 Electrical connection5

More information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance NEW Safety Light Curtain MS4800 Series Strong, Durable Body and Long, 20-m Sensing Distance A Powerful Safety Light Curtain with Durable, Impact-resistant Body and Long, 20-m Sensing Distance Has Arrived.

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: XRT910-0-0-GB-XX XRT911-0-0-GB-XX XTT911-0-0-NN-XX IMPROX TRT ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL Working Environment XRT910-0-0-GB-XX... (Aluminium Extruded

More information

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass SPECTRO Series SPECTRO-3-SLU-BA-ANA + SI-SLU-16 - Measuring range in reflected light operation typ. 100 mm... 1000 mm, in transmitted light operation typ. 100 mm... 5000 mm - Up to 3 colors (max. 64 in

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10)

SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10) SPECTRO Series - Measuring range typ. 10 mm... 150 mm - Big dynamic range due to focused white-light operation - Up to 31 colors can be stored - RS232 interface (USB or Ethernet adapter is available) -

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC

More information

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that

More information

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s 120531 M5-H002 Multiview T-35 DVB-T to PAL / 5 channels on all TV s Contents Multiview... 3 Features... 3 Caution... 3 Front & Rear Panel... 4 Connecting... 5 Programming... 6 Information... 7 Installation...8

More information

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1. Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface control motion interface ZU 252 Incremental Counter Module With Analogue Output and Serial Interface Counter suitable for quadrature signals (A/B, 90º) as well as single channel inputs Counting inputs

More information

INSTALLATION & USER GUIDE

INSTALLATION & USER GUIDE INSTALLATION & USER GUIDE Digidim 458 8-Channel Dimmer STEP 1 Assemble Dimmer Unit STEP 2 Mount Dimmer Chassis STEP 3 Electrical Installation STEP 4 Attach Module and Make Connections STEP 5 Replace Cover

More information

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Contents 1) Grid-Tie Installation Block Diagram... 3 2) Installation Steps.... 4 2.1) Initial Setup.... 4 2.1.1)

More information

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description Component Systems Technical Description Features Applications The mini optical series of sensors are among smallest sensors in the world. Mini optical sensors require almost no space and with their low

More information

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface control motion interface IV 251 Signal Converter SSI Analogue and SSI Serial Suitable for operation with all sensors and encoders using SSI interface Scalable analogue outputs +/- 10 volts, 0-20 ma and

More information

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com ZU 252 Incremental Counter Module

More information

DT1-PCM21. for Porsche PCM2.1 navigation systems

DT1-PCM21. for Porsche PCM2.1 navigation systems Product features dvblogic DVB-T Tuner for Porsche PCM2.1 navigation systems Full plug and play vehicle-specific dual DVB-T Tuner + USB-AV-Player DVB-T-Tuner MPEG4 compatible (HD) USB-AV-Player for USB-media

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application

More information

Vision Sensor Short Manual

Vision Sensor Short Manual Vision Sensor FQ Short Manual Cat. No. Z306-E1-02A Table of Contents 1. Introduction 1-1 FQ-series Vision Sensors....................................... 4 1-2 Measurement Process.........................................

More information

CARLO GAVAZZI Automation Components

CARLO GAVAZZI Automation Components CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs

More information

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com IV 251 Signal Converter SSI => Analogue

More information

Syntor X Flash Memory Module Revision C

Syntor X Flash Memory Module Revision C Syntor X Flash Memory Module Revision C The PIEXX SynXFlash memory module, along with the supplied PC software, replaces the original SyntorX code plugs and allows you to easily set modify and update your

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03 of Re:connect M 203 RS232 Interface Revox Dominating Entertainment. Revox of Switzerland. E 2.03 Attention! After updating the firmware to version 2.00 or higher, we recommend completely resetting the

More information

Video Server SED-2100R/S. Quick Installation Guide

Video Server SED-2100R/S. Quick Installation Guide Video Server SED-2100R/S Quick Installation Guide Feb.10,2006 1 1 Getting Started 1.1 PACKAGE CONTENTS SED-2100 Warranty Card Software CD Hook up & Screws Terminal Blocks for Power & DI/O Power Adaptor

More information

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global Contact-Type Digital Displacement Sensor HG-S Series User's Manual WUME-HGS-4 2017.1 panasonic.net/id/pidsx/global (MEMO) 2 Panasonic Industrial Devices SUNX Co., Ltd. 2017 Thank you for purchasing an

More information

Azatrax Model Railroad Track Signal Control - Single Track

Azatrax Model Railroad Track Signal Control - Single Track Installation Guide Azatrax Model Railroad Track Signal Control - Single Track TS2 What it is: The TS2 operates one or two trackside block signals (one in each direction) on one track to simulate the block

More information

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE JY992D52801C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX-2DA special

More information

Smart-Encoder : Optical Incremental

Smart-Encoder : Optical Incremental 1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables

More information

MXS Strada USER GUIDE

MXS Strada USER GUIDE MXS Strada USER GUIDE AiM TECH Srl. Via Cavalcanti, 8 20063 Cernusco S/N (MI) Italia Tel. (+39) 02.9290571 Made in Italy www.aim-sportline.com MXS Strada 01. INTRODUCTION 02. WHAT IS IN THE KIT 03. LAYOUT

More information

5024 WEIGHING TERMINAL

5024 WEIGHING TERMINAL Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 5024 WEIGHING TERMINAL Basic system with automatic dosing Applies to: Software: Document no.: STDLIM.140630.1v1

More information

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2 dvblogic DVB-T Tuner Compatible with Land Rover touch-screen navigation systems version 2 Product features Full plug and play vehicle-specific dual DVB-T Tuner + USB-AV-Player DVB-T-Tuner MPEG4 compatible

More information

of Loewe E 2.10_m1 1

of Loewe E 2.10_m1 1 of Loewe E 2.10_m1 1 Attention! After updating the M203 firmware to version 2.00 or higher, we recommend completely resetting the M203 interface by pressing the Disable softkey on setup page #2 for several

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1. STRA communication The types of the signals (types in the list below): 1 = Coil Status Register ( function = 1, 5 and 15) - 0x 2 = Discrete Input ( function = 2) - 1x 3 = Holding Register ( function =

More information

WF next: Fork sensors for a wide range of applications

WF next: Fork sensors for a wide range of applications WF next: Fork sensors for a wide range of applications D ATA S H E E T Fork sensors TThe detection of labels, marks and double sheets, as well as holes and edges are typical applications for the new WF

More information

Safety Light Curtain Type4 SIL3 PLe

Safety Light Curtain Type4 SIL3 PLe Maximum safety standard Type4 SIL3 PLe Safety Light Curtain GL-R Series Unmatched Protection! Safety Light Curtain Strong Smart Simple GL-R Series SAFETY LIGHT CURTAINS DESIGNED FOR ANY APPLICATION RECESSED

More information

REMOTE DISPLAY WIRELESS DECODER MK II

REMOTE DISPLAY WIRELESS DECODER MK II REMOTE DISPLAY WIRELESS DECODER MK II INSTALLATION MANUAL Part No. LED-DEC 1. Contents 1. Contents... 1 2. Equipment List... 2 3. Overview... 2 Introduction... 2 Location Selection **Important **... 2

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information

Camera Setup Instructions

Camera Setup Instructions Camera Setup Instructions Hopefully this document will help new MallinCam owners set up their systems and get them to successful first light more quickly. Through the use of images, I hope to describe

More information

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc

More information

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE JY992D6520B This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4AD and should

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

Car-Solutions.com. GVIF Video Interface for Opel, Buick, Chevrolet. ver Manual

Car-Solutions.com. GVIF Video Interface for Opel, Buick, Chevrolet. ver Manual GVIF Video Interface for Opel, Buick, Chevrolet www.car-solutions.com Release date: 2012.02.04 Model: GF08BU-V6.2 / Product code: GF-0811-000 ver. 6.2 Manual support@carsolutions.com.ua Contents 1. Before

More information

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised SECU-16 Introduction The SECU-16 module allows 8 inputs and 8 low-current relay outputs to be added to an ADICON control system. The inputs may be supervised (switch closure), analog, or 4-20mA. Specifications

More information

Extra long-range RFID (proximity) card reader

Extra long-range RFID (proximity) card reader GP90A Extra long-range RFID (proximity) card reader (1) Features: Extra long reading range of up to 90 cm with ISO-size passive RFID cards*, over 100 cm with special optimized passive cards High-precision

More information

C Module Description

C Module Description IQMMX -Input Router & ASI Distribution Amplifier C Module Description The IQMMX is an ASI to 1 switch, distribution amplifier and transport stream switcher with up to 8 outputs in double width form or

More information

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE Product code: RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE TVRGBDMX88ST A Master receiver with DMX/DALI Slave TVSMX000A0 input TVRGBD000ST A Slave receiver -Vdc power supply IN P P P Led Led Led

More information

Video wall Precautions when moving and handling. Precaution. Please adhere to the warning signs printed on the box.

Video wall Precautions when moving and handling. Precaution. Please adhere to the warning signs printed on the box. Video wall Precaution 4-1. Precautions when moving and handling Please adhere to the warning signs printed on the box. Model: 47WV30MS 47WV30BR 47WV30BS 47WV30-BAAM 47WV30-BAAL 47WV50BR 47WV50MS 47LV35A

More information

W 9-2: A Versatile, Complete and Compact Series

W 9-2: A Versatile, Complete and Compact Series suitable sensor can be selected from the W 9- series. Overview of the sensors: WT 9-, with adjustable background suppression, max. scanning distance 0 mm, WT 9-, energetic, max. scanning distance 0 mm,

More information

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE Table of Contents AS-Interface Basics... 3 Addressing Modules... 4 Handheld Programmer (Reading Inputs and Settings Outputs)... 5 Gateway

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO Style 12 INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO INSTALLATION AND OPERATING INSTRUCTIONS B.P. 1 49340 TRÉMENTINES FRANCE Tél. : 02 41 71 72 00 Fax : 02 41 71 72 01 www.bodet.com Réf. :

More information

END USER MANUAL DAS-M44HD-R

END USER MANUAL DAS-M44HD-R END USER MANUAL DAS-M44HD-R Warnings: Important Safety Instructions and Caution Please read all of these instructions regarding your unit and retain them for future reference Read this manual fully and

More information

Pulse Concentrator User Manual EPC-12

Pulse Concentrator User Manual EPC-12 WARNING Ignoring the instructions in this manual may result in serious injuries or death. Disconnect all power supply inputs before connecting the device. Do not remove the front panel when device is connected

More information

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8 Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.

More information

Multicom Optical Return Path Receiver MUL HRPR 4B

Multicom Optical Return Path Receiver MUL HRPR 4B Multicom Optical Return Path Receiver User Manual v.9 www.multicominc.com 800 423 2594 407 331 7779 1076 Florida Central Parkway, Longwood, FL 32750 SAFETY NOTIFICATION Multicom strongly advises you to

More information

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1

More information

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER TOUCHLESS SWITCHES. WHEN THE DESIN NEEDS TO E ASOLUTELY PEFECT -300-X SEQUENCE / 3-CHANNEL UNIVESAL LED DIMME Description -300-X is a dual function unit and can operate in two distinct modes. In Mode the

More information

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions For installation queries contact Customer Services +49 - (0)3 69 25-9 00 90 kundenservice@rutenbeck.de TCR IP 4 Operating instructions GB Device overview External buttons (for manual switching) Temperature

More information

DT1-LR. for Landrover touch-screen navigation systems version 1

DT1-LR. for Landrover touch-screen navigation systems version 1 dvblogic DVB-T Tuner for Landrover touch-screen navigation systems version 1 Product features Full plug and play vehicle-specific dual DVB-T Tuner + USB-AV-Player DVB-T-Tuner MPEG4 compatible (HD) USB-AV-Player

More information

SA1J-F: Full Color Fiber Optic Sensors

SA1J-F: Full Color Fiber Optic Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain ice: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com This new line of full color sensors offers

More information

DVB-C20. Compatible with navigation systems Mercedes Benz Comand 2.0 Comand APS CD Comand APS 220

DVB-C20. Compatible with navigation systems Mercedes Benz Comand 2.0 Comand APS CD Comand APS 220 dvblogic DVB-T Tuner Compatible with navigation systems Mercedes Benz Comand 2.0 Comand APS CD Comand APS 220 Product features full plug and play vehicle-specific dual DVB-T Tuner with two active DVB-T

More information

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226 MONOPRICE BitPath AV VGA Extender over Single Cat6 Cable, 120m P/N 16226 User's Manual SAFETY WARNINGS AND GUIDELINES Please read this entire manual before using this device, paying extra attention to

More information

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps: Overview Shipped in the Venue Vizion Package: Four two-channel QMOD Encoder-Modulators Each unit can accept up to 2 inputs, providing up to 8 channels in the system. One ICE-HE-DXL Display Control Center

More information

DT1-NTG2. Compatible with Mercedes Benz Comand APS NTG2 navigation systems

DT1-NTG2. Compatible with Mercedes Benz Comand APS NTG2 navigation systems dvblogic DVB-T Tuner Compatible with Mercedes Benz Comand APS NTG2 navigation systems Product features Full plug and play vehicle-specific dual DVB-T Tuner + USB-AV-Player DVB-T-Tuner MPEG4 compatible

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

XCOM1002JE (8602JE) Optical Receiver Manual

XCOM1002JE (8602JE) Optical Receiver Manual XCOM1002JE (8602JE) Optical Receiver Manual - 2 - 1. Product Summary XCOM1002JE (8602JE) outdoor optical receiver is our latest 1GHz optical receiver. With wide range receiving optical power, high output

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES SAFETY WARNINGS AND GUIDELINES Please read this manual thoroughly, paying extra attention to these safety warnings and guidelines: Do not expose this monitor to water or moisture of any kind. Do not handle

More information

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE Product code: TVRGBDSYA0 Syncroled Master receiver 0mA TVRGBDSYM0 Syncroled receiver 0mA TVRGBDSYB0 Syncroled Master receiver 00mA TVRGBDSYN0 Syncroled

More information

USER MANUAL. VP-435 Component / UXGA HDMI Scaler MODEL: P/N: Rev 13

USER MANUAL. VP-435 Component / UXGA HDMI Scaler MODEL: P/N: Rev 13 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-435 Component / UXGA HDMI Scaler P/N: 2900-000262 Rev 13 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is

More information

HygroClip Introduction

HygroClip Introduction What is the HygroClip? HygroClip ntroduction he HygroClip is a high quality probe for the measurement of humidity and temperature. t is used in a wide range of applications including handheld instruments,

More information

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO ALARM VERIFICATION UNIT VIVER VIDEO ALARM VERIFICATION UNIT VIVER viver_en 09/08 The VIVER module provides remote video alarm verification, based on image sequences transmitted from cameras installed in the protected facility. The

More information

Professional-Practice

Professional-Practice www.osram.com/ecg-lms Professional-Practice DALI MCU: Digital potentiometer with DALI Manual lighting control with the DALI MCU for rooms with grouped luminaires with as many as 50 ECG, with or without

More information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display Sens Mini-Cube Sens with Easy-to-Read LED Display Industry s smallest, lightest l Both analog bar and digital pressure values are displayed Two independent outputs plus one analog output are available

More information

C-net WIND. User s Guide

C-net WIND. User s Guide C-net WIND User s Guide EMC Directive 89/336/EEC This product has been designed to be compliant with the above EMC Directive. Maximum performance and compliance with the EMC Directive can only be ensured

More information

Chapter 23 Dimmer monitoring

Chapter 23 Dimmer monitoring Chapter 23 Dimmer monitoring ETC consoles may be connected to ETC Sensor dimming systems via the ETCLink communication protocol. In this configuration, the console operates a dimmer monitoring system that

More information

Knocking detector device DENOX 2, DENOX 20. User guide. HW & SW versions, December 2006

Knocking detector device DENOX 2, DENOX 20. User guide. HW & SW versions, December 2006 Knocking detector device DENOX 2, DENOX 20 HW & SW versions, December 2006 User guide Copyright 2006 ComAp s.r.o. Prague, Czech Republic ComAp, spol. s r.o. Světova 7, 180 00 Praha 8, Czech Republic Tel:

More information

USER MANUEL. SNIPE 2 Ref R13

USER MANUEL. SNIPE 2 Ref R13 USER MANUEL SNIPE 2 Ref. 0141317R13 Contents 1. General Information 1-1. Introduction 1-2. Proper use and operation 1-3. Safety notes......... 2 3 3 2. Contents 2-1. Accessory included 2-2. Name of parts......

More information

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual ZyCastR digi-mod HD Range digi-mod HD-1603 www.digi-modbyzycast.com HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual Table of Contents www.digi-modbyzycast.com Safety

More information

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple

More information

Vorne Industries. 2000B Series Buffered Display Users Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 2000B Series Buffered Display Users Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 2000B Series Buffered Display Users Manual 1445 Industrial Drive Itasca, IL 60141849 (60) 875600 elefax (60) 875609 Page 2 2000B Series Buffered Display 2000B Series Buffered Display Release

More information