!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter"

Transcription

1

2

3 Model490 Dual Input, Dual Trace Automatic Peak Power Meter No other power meter can offer you these features: Help Mode: A Help Mode feature has been added to the Model 490 Automatic Peak Power Meter. This feature provides information for all of the 490 key functions. Automatic Operation: Automatically selects optimal time base and power range. Dual Trace Operation: Presents pulse waveforms of two traces on a calibrated graphic display. Power Measurements: Automatically measures and digitally displays peak and instantaneous power values on linear or logarithmic scales. Automatic Pulse Parameter Measurements: Measures rise time, fall time, pulse width and period with a single command. 7" Color CRT Display: Utilizes 3 colors to provide a clear presentation of both measured waveforms. Intelligent Power Head: Supplies power meter with appropriate frequency compensation and square law correction values along with the measurement data. May be field calibrated. Trace Storage: Can store and display a pulse trace while viewing a second incoming trace. GPIB Programmability: All instrument functions may be controlled via a GPIB interface making completely automatic signal acquisition and analysis available. Performance Verification: Instrument is furnished with a built-in 1 GHz reference oscillator. The Model 490 Automatic Peak Power Meter with its associated Model N439, M439, MK439, or A439 Power Head produces a flexible, powerful, versatile, accurate and simple to use instrument. The capability of measuring peak power and presenting on a CRT both the calibrated microwave pulse and a digital display of measured power values was an innovative design concept first introduced with General Microwave's Model 478 Automatic Peak Power Meter. This concept has been further enhanced in the Model 490, to permit two pulses to be displayed on a calibrated graph along with the measured values for an analysis of each pulse. These units offer simultaneous viewing and pulse analysis of two microwave signals with pulse widths as small as 15 nanoseconds. The pulses may be derived from the dual power head inputs or from one input and a stored reference. The Model 490 is equipped with a three color CRT display on which each pulse is displayed in a separate color providing an unambiguous presentation of both traces. Pulse parameters such as rise and fall time, pulse width and period can be measured automatically with the touch of a single button eliminating the uncertainty of manually selecting reference power levels. Gain and loss measurements, in either linear or logarithmic units, are performed automatically using the A/B ratio mode. The instrument has the capability of storing user programmed setup menus, which permit rapid access to as many as eight frequently used, desired test conditions. Total control of all of the features of the instrument. may be exercised via the keyboard or via the IEEE-488 General Purpose Interface Bus (GPIB). The power heads contain an EEPROM which automatically supplies the power meter with the appropriate linearity and frequency correction data. The EEPROMs are field programmable and permit field calibration of the power heads through the power meter keyboard or the GPIB.!Ill ~ 168

4 Model490 Specifications POWER RANGE: Normal Range: to + 15 dbm with N439-14to +15dBmwithM439, MK439, A439 Extended Range: to + 15 dbm with N to + 15 dbm with M439, MK439, A439 PULSE WIDTH: Normal Range: nsec to 1 sec and CW Extended Range:.. 1.5J.lsec to 1 sec and CW VIDEO BANDWIDTH AND RISE/FALL TIME (1 0-90%/90-10% )!1); Normal Range: MHz, 10 nsec Extended Range: khz, 700 nsec FREQUENCY RANGE: to 18 GHz with N to 40 GHz with MK to 26.5 GHz with M to 40 GHz with A439 ACCURACY: See figure 1 MAXIMUM SAFE INPUT POWER: + 20 dbm CW, + 30 dbm peak (1 1-1sec max pulse width, 1% duty cycle) FREQUENCY RESPONSE: Compensated:.... ± 0.1 db to 18 GHz ± 0.3 db to 26.5 GHz (M439, MK439) ± 0.3 db to 40 GHz (MK439) ± 0.3 db 26.5 to 40 GHz (A439) Uncompensated:.. ± 0.3 db to 8 GHz INPUT IMPEDANCE: Coaxial models 50 ohms nominal ± 0.5 db to 18 GHz ± 1.0 db to 26.5 GHz (M439, MK439) ± 1.5 db to 40 GHz (MK439) ± 1.8 db 26.5 to 40 GHz (A439) VSWR: N :1 to 8 GHz 1.4:1 to 18GHz M439, MK :1 to 8 GHz 1:35:1 to 18GHz 1.7:1 to 26.5 GHz MK :1 to 40 GHz A : to 40 GHz POWER SCALE RANGE: From 0.1 to 20 dbm (or db)/division or 1 1-1W to 2 MW/division in a sequence. RELATIVE OFFSET RANGE: From to db TIME BASE RANGE: From 10 nsec/division to 100 msec/division in a sequence TIME MEASUREMENT ACCURACY: Dependent on Ts (Ts =trigger to sample time) When: 1 nanosec.:5 Ts.:51 microsec Then: Accuracy =.005% or 2 nsec, whichever is greater When: 1 microsec < Ts.:51 second Then: Accuracy =.005% or 10 nsec, whichever is greater TRIGGER DELAY RANGE: From 1 nsec to 1 sec with resolution of 1 nsec EXTERNAL TRIGGER REQUIREMENTS: 50 ohm Input: V to + 5 V into 50 ohms 300 nsec rise time max TTL Input: unit load positive pulse NOMINAL MEASUREMENT TIME: 2 sec<2l per trace INTERNAL TRIGGER LEVEL RANGE: Normal Range: to + 15 dbm (N439) - 5 to + 15 dbm (M439, MK439, A439) Extended Range: to + 15 dbm (N439) - 15to +15dBm(M439, MK439, A439) DISPLAY: 7" CRT with liquid crystal color shutter. Graph area is 201 horizontal by 151 vertical cells which are organized into 10 horizontal and 5 vertical major divisions. DISPLAY OFFSET RANGE: Up to 2 MW or 0 to dbm (or db) DISPLAY MODES: Single or Dual Alternate Trace. Input A, Input B, Memory, AlB or A/Memory! 1) See description of Power Head Options. 2) AI 201 samples per sweep in Manual mode; faster at lower number of samples; slower in Automatic mode or with wide or low repetition ra te pulses. 169

5

Agilent 5345A Universal Counter, 500 MHz

Agilent 5345A Universal Counter, 500 MHz Agilent 5345A Universal Counter, 500 MHz Data Sheet Product Specifications Input Specifications (pulse and CW mode) 5356C Frequency Range 1.5-40 GHz Sensitivity (0-50 deg. C): 0.4-1.5 GHz -- 1.5-12.4 GHz

More information

8650A SERIES UNIVERSAL POWER METERS

8650A SERIES UNIVERSAL POWER METERS 8650A SERIES UNIVERSAL METERS 8650A SERIES UNIVERSAL METERS The Capabilities to Test Today s Sophisticated Communications Systems TIME BURST AVERAGE The Giga-tronics 8650A Series Universal Power Meters

More information

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Frequency Hewlett Packard 3577A 5Hz - 200 MHz Network Analyzer Specifications SOURCE 5 Hz - 200 MHz 0.001 Hz Amplitude

More information

JD725A Cable and Antenna Analyzer - Dual Port

JD725A Cable and Antenna Analyzer - Dual Port COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD725A Cable and Antenna Analyzer - Dual Port Key Features Portable and lightweight handheld instrument Built-in wireless frequency bands as well as the most

More information

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel) Digital Delay / Pulse Generator Digital delay and pulse generator (4-channel) Digital Delay/Pulse Generator Four independent delay channels Two fully defined pulse channels 5 ps delay resolution 50 ps

More information

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators Technical Brief Quickly and easily apply a level correction table to compensate for external losses or power variations

More information

Over 5000 VXI cards and mainframes in stock. 1000's of pieces of Test Equipment in stock. Looking for Test Equipment? Visit us on the web at www.recycledequipment.com Recycled Equipment buys, sells, and

More information

R-1550A Tempest Wide Range Receiver

R-1550A Tempest Wide Range Receiver R-1550A Tempest Wide Range Receiver Product Brochure Version 0.2.00 April 2008 Dynamic Sciences International, Inc. R-1550A TEMPEST Wide Range Measurement Receiver Made specifically for TEMPEST testing

More information

USB-TG124A Tracking Generator User Manual

USB-TG124A Tracking Generator User Manual USB-TG124A Tracking Generator User Manual Signal Hound USB-TG124A User Manual 2017, Signal Hound, Inc. 35707 NE 86th Ave La Center, WA 98629 USA Phone 360.263.5006 Fax 360.263.5007 This information is

More information

Agilent 8757D Scalar Network Analyzer

Agilent 8757D Scalar Network Analyzer Agilent 8757D Scalar Network Analyzer Data Sheet Accurate measurement of transmission and reflection characteristics is a key requirement in your selection of a scalar network analyzer. To help you achieve

More information

SYNTHESIZED COMMUNICATION CONVERTERS

SYNTHESIZED COMMUNICATION CONVERTERS Dual-Conversion 1 khz or 125 khz Step Size SYNTHESIZED COMMUNICATION CONVERTERS 9600 SERIES 9400 SERIES MITEQ offers high-performance synthesized frequency converters in panel heights of 2 RU (9400 Series)

More information

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The

More information

CDMA2000 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock

CDMA2000 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock Products: CMU200 CDMA2000 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock This application explains the setup and procedure to measure the exact time relationship

More information

Supplements to the FSP Operating Manual TV-Demodulator

Supplements to the FSP Operating Manual TV-Demodulator Test and Measurement Division Supplements to the FSP Operating Manual TV-Demodulator FSP-B6 1129.8642.02 Dear FSP Customer, The following collection of pages is intended to supplement your FSP operating

More information

VXIbus Microwave Downconverter

VXIbus Microwave Downconverter 1313B Phase Matrix, Inc ṬM Instruments You Can Count On VXIbus Microwave Downconverter High-Performance Downconversion For Analysis of Microwave Signals 1 MHz to 26.5 GHz Frequency Range -135 to +30 dbm

More information

4.9 BEAM BLANKING AND PULSING OPTIONS

4.9 BEAM BLANKING AND PULSING OPTIONS 4.9 BEAM BLANKING AND PULSING OPTIONS Beam Blanker BNC DESCRIPTION OF BLANKER CONTROLS Beam Blanker assembly Electron Gun Controls Blanker BNC: An input BNC on one of the 1⅓ CF flanges on the Flange Multiplexer

More information

R&S ZND Vector Network Analyzer Specifications

R&S ZND Vector Network Analyzer Specifications R&S ZND Vector Network Analyzer Specifications year Test & Measurement Data Sheet 02.01 CONTENTS Definitions... 3 Measurement range... 4 Measurement speed... 5 Measurement accuracy... 7 Effective system

More information

R&S ZNBT Vector Network Analyzer Specifications

R&S ZNBT Vector Network Analyzer Specifications R&S ZNBT Vector Network Analyzer Specifications year Data Sheet Version 05.02 CONTENTS Definitions... 3 Measurement range... 4 Measurement speed... 6 Measurement accuracy of the R&S ZNBT8... 8 Measurement

More information

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. Multichannel Scaler Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution. The ideal solution for: Time-resolved single-photon counting Phosphorescence lifetime spectrometry Atmospheric and

More information

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO) 2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency

More information

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure TRANSCOM T5000 Series Bench-top Vector Network Analyzer Overview T5000 Series bench-top vector network analyzer offers the high

More information

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display SR850 DSP Lock-In Amplifier 1 mhz to 102.4 khz frequency range >100 db dynamic reserve 0.001 degree phase resolution Time constants

More information

RF Level Test System +20 dbm to 130 dbm

RF Level Test System +20 dbm to 130 dbm NRVD Power Meter optional Therm. Sensor A B Power: >-15 dbm DUT (Signal Generator, Communication Tester) 1 MHz - 3.5/6 GHz +20 dbm... -130 dbm Diode Sensor Z4 Power: -15 to -40 dbm 6 db Power =< -40 dbm

More information

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum.

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum. RF Explorer RackPRO User Manual Introduction Greetings fellow traveler on the RF spectrum. The RF Explorer RackPRO (referred to in this document in shorthand as RackPRO ) has been designed to be intuitive

More information

Portable Performance for Debug and Validation

Portable Performance for Debug and Validation WaveJet 300A Oscilloscopes 100 MHz 500 MHz Portable Performance for Debug and Validation A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES Key Features 100 MHz, 200 MHz, 350 MHz and 500 MHz bandwidths Sample

More information

Sources of Error in Time Interval Measurements

Sources of Error in Time Interval Measurements Sources of Error in Time Interval Measurements Application Note Some timer/counters available today offer resolution of below one nanosecond in their time interval measurements. Of course, high resolution

More information

TRM Module. l TRM = Transmitter Receiver Module. l Communication to the module is essential. l Each module is individually tested

TRM Module. l TRM = Transmitter Receiver Module. l Communication to the module is essential. l Each module is individually tested T/R Module Test TRM Module l TRM = Transmitter Receiver Module l Communication to the module is essential l Each module is individually tested l Test equipment must be protected due to high Tx power l

More information

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications March 2006 Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical

More information

SMS3000X Series Spectrum Analyzer

SMS3000X Series Spectrum Analyzer Data Sheet SMS3000X Series Spectrum Analyzer SMS3032X SMS3021X General Description SMS3000X series spectrum analyzer has a frequency range from 9 khz up to 2.1 GHz/3.2 GHz, it is light weight and small

More information

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Oscilloscope Guide Tektronix TDS3034B & TDS3052B Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic

More information

Fox-Bus (FxB) Protocol Timing (Version 4) 9/1/2011

Fox-Bus (FxB) Protocol Timing (Version 4) 9/1/2011 Fox-Bus (FxB) Protocol Timing (Version 4) 9/1/2011 Legend: The term valid or reliable means that the state has been longer than 2us in duration Heavy (thick) lines are periods when bus is driven by low-z

More information

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X Spectrum Analyzer 1.6 GHz 3 GHz 1 Basic Unit + 3 Options Your Spectrum Analyzer Key facts Frequency range: 100 khz to 1.6 GHz/3 GHz* 1 Spectral purity greater than -100 dbc/hz (at 100 khz) SWEEP from 20

More information

2 MHz Lock-In Amplifier

2 MHz Lock-In Amplifier 2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric

More information

Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules

Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules Ihr Spezialist für Mess- und Prüfgeräte Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules Data Sheet Introduction See the TRUE performance of your designs.

More information

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview Agilent E5500 Series Phase Noise Measurement Solutions Product Overview E5501A/B E5502A/B E5503A/B E5504A/B 50 khz to 1.6 GHz 50 khz to 6 GHz 50 khz to 18 GHz 50 khz to 26.5 GHz The Agilent E5500 series

More information

Programmable Power Supplies 188 W 384 W R&S HMP Series

Programmable Power Supplies 188 W 384 W R&S HMP Series Programmable Power Supplies 188 W 384 W R&S HMP Series Test & Measurement Product Brochure 02.01 R&S HMP Series The R&S HMP Series Key facts Low residual ripple due to linear post-regulators Real-time

More information

SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals

SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals Version 1.6-06/01/2005 This document is the result of a cooperative effort undertaken by the SatLabs Group. Neither the SatLabs

More information

Application Note DT-AN DTU-315 Verification of Specifications

Application Note DT-AN DTU-315 Verification of Specifications DTU-315 Verification of Specifications APPLICATION NOTE January 2018 Table of Contents 1. Introduction... 3 General Description of the DTU-315... 3 Purpose of this Application Note... 3 2. Measurements...

More information

Camera Interface Guide

Camera Interface Guide Camera Interface Guide Table of Contents Video Basics... 5-12 Introduction...3 Video formats...3 Standard analog format...3 Blanking intervals...4 Vertical blanking...4 Horizontal blanking...4 Sync Pulses...4

More information

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012 Revision 1.11 19-Jul 2012 Agilent Method of Implementation (MOI) for HDMI 1.4b Cable Assembly Test Using Agilent E5071C ENA Network Analyzer Option TDR 1 Table of Contents 1. Modification Record... 4 2.

More information

Rec. ITU-R BT RECOMMENDATION ITU-R BT PARAMETER VALUES FOR THE HDTV STANDARDS FOR PRODUCTION AND INTERNATIONAL PROGRAMME EXCHANGE

Rec. ITU-R BT RECOMMENDATION ITU-R BT PARAMETER VALUES FOR THE HDTV STANDARDS FOR PRODUCTION AND INTERNATIONAL PROGRAMME EXCHANGE Rec. ITU-R BT.79-4 1 RECOMMENDATION ITU-R BT.79-4 PARAMETER VALUES FOR THE HDTV STANDARDS FOR PRODUCTION AND INTERNATIONAL PROGRAMME EXCHANGE (Question ITU-R 27/11) (199-1994-1995-1998-2) Rec. ITU-R BT.79-4

More information

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing Application Note #63 Field Analyzers in EMC Radiated Immunity Testing By Jason Galluppi, Supervisor Systems Control Software In radiated immunity testing, it is common practice to utilize a radio frequency

More information

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series arris.com OmniStar GX2 Headend Optics Platform GX2 LM1000E Series 1310 nm Broadcast Transmitter FEATURES High density optical platform with up to 16 transmitters per chassis for headend space optimization

More information

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

RS Pro SPECTRUM ANALYZER SSA3000X SERIES Product Datasheet ENGLISH Stock No: 1236443 (RSSA3021X) 1236444 (RSSA3032X) RS Pro SPECTRUM ANALYZER SSA3000X SERIES Features and Benefits RSSA3032X XX RSSA3021X All-Digital IFTechnology Frequency Range

More information

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope Benefits of the R&S RTO Oscilloscope's Digital Trigger Application Note Products: R&S RTO Digital Oscilloscope The trigger is a key element of an oscilloscope. It captures specific signal events for detailed

More information

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS 11 GHz MDD FIBER OPTIC LINK FEATURES Small size Bandwidth to 11 GHz Plug-in optical connector No external control circuits required Transimpedance amplifier in both transmitter and receiver Custom transmitter

More information

LeCroy Digital Oscilloscopes

LeCroy Digital Oscilloscopes LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,

More information

UFX-EbNo Series Precision Generators

UFX-EbNo Series Precision Generators With compliments UFX-EbNo Series Precision Generators Precision E b /N o (C/N) Generators UFX-EbNo Series Precision E b /N The UFX-EbNo is a fully automated instrument that sets and maintains a highly

More information

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz Power_sensors_bro_en_3606-7147-32.indd 1 22.05.2014 14:08:59 Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz The most important

More information

RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER

RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER Introduction Recording RF Signals WHAT DO WE USE TO RECORD THE RF? Where do we start? Swept spectrum analyzer Real-time spectrum analyzer Oscilloscope

More information

High-Definition, Standard-Definition Compatible Color Bar Signal

High-Definition, Standard-Definition Compatible Color Bar Signal Page 1 of 16 pages. January 21, 2002 PROPOSED RP 219 SMPTE RECOMMENDED PRACTICE For Television High-Definition, Standard-Definition Compatible Color Bar Signal 1. Scope This document specifies a color

More information

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Manual of Operation for WaveNode Model WN-2m. Revision 1.0 Manual of Operation for WaveNode Model WN-2m. Revision 1.0 TABLE OF CONTENTS 1. Description of Operation 2. Features 3. Installation and Checkout 4. Graphical Menus 5. Information for Software Expansion

More information

Measuring with digital storage oscilloscopes

Measuring with digital storage oscilloscopes Markus Reil, Rainer Wagner 2.2016 1MAA265-1e Educational note Measuring with digital storage oscilloscopes Educational note Products: ı R&S HMO1002 This educational note covers the theory and practice

More information

RF Solutions for Science.

RF Solutions for Science. RF Solutions for Science www.thalesgroup.com State-of-the-art RF sources for your scientific needs High-power klystrons HIGH KLYSTRONS WITH RF LONG PULSE above 50 μs Thales has been one of the leading

More information

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz Fast. Accurate. USB-capable. Power from Rohde & Schwarz Power bro_en_3606-7147-32.indd 1 01.08.2013 16:57:35 Fast. Accurate. USB-capable. Power from Rohde & Schwarz The most important features for accurate

More information

Keysight Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules. Data Sheet

Keysight Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules. Data Sheet Keysight Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules Data Sheet Introduction Table of Contents See the TRUE performance of your designs. The 86100D DCA-X performs precision

More information

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum

More information

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals By Jean Dassonville Agilent Technologies Introduction The

More information

SigPlay User s Guide

SigPlay User s Guide SigPlay User s Guide . . SigPlay32 User's Guide? Version 3.4 Copyright? 2001 TDT. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or

More information

HX0074 DEMO Kit for METRIX Oscilloscopes

HX0074 DEMO Kit for METRIX Oscilloscopes GB - User s Guide HX0074 DEMO Kit for METRIX Oscilloscopes DIGITAL OSCILLOSCOPES 1 HX0074 Demo Kit for METRIX Oscilloscopes General description The oscilloscope kit features a circuit which generates 15

More information

Agilent 8560 E-Series Spectrum Analyzers

Agilent 8560 E-Series Spectrum Analyzers Agilent 8560 E-Series Spectrum Analyzers Data Sheet 8560E 30 Hz to 2.9 GHz 8561E 30 Hz to 6.5 GHz 8562E 30 Hz to 13.2 GHz 8563E 30 Hz to 26.5 GHz 8564E 30 Hz to 40 GHz 8565E 30 Hz to 50 GHz 8565E SPECTRUM

More information

Limitations of a Load Pull System

Limitations of a Load Pull System Limitations of a Load Pull System General Rule: The Critical Sections in a Load Pull measurement setup are the sections between the RF Probe of the tuners and the DUT. The Reflection and Insertion Loss

More information

RF Signal Capture & Playback Simple Operation Guide

RF Signal Capture & Playback Simple Operation Guide User Guide RF Signal Capture & Playback Simple Operation Guide Signal Analyzer and Built-in Vector Signal Generator Option MS2690A Series MS2830A (3.6/6.0/13.5 GHz Model) MS2840A (3.6/6.0 GHz Model) This

More information

VPO Technology 1 / 6 GOOD WILL INSTRUMENT CO., LTD.

VPO Technology 1 / 6  GOOD WILL INSTRUMENT CO., LTD. VPO Technology 1 / 6 The GW Instek GDS-3000 Series digital storage oscilloscopes are equipped with a built-in self-developed waveform image processing system which significantly enhances the waveform capture

More information

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZVA110 Vector Network Analyzer Specifications ZVA110_dat-sw_en_5214-4813-22_cover.indd 1 Data Sheet 04.00 Test & Measurement R&S ZVA110 Vector Network Analyzer Specifications 15.11.2013 14:42:28 CONTENTS Definitions... 3 Specifications... 4 Overview...

More information

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5 USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5 Triarchy Technologies, Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013

More information

Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview

Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview Agilent Technologies 53200 Series of RF and Universal Frequency Counter/Timers Family Overview I never expected a frequency counter to do so much, so fast. Speed, resolution, and accuracy are just the

More information

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC Originally appeared in the July 2006 issue of Communications Technology. TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC Digitally modulated signals are a fact of life in the modern cable

More information

Spatial Light Modulators XY Series

Spatial Light Modulators XY Series Spatial Light Modulators XY Series Phase and Amplitude 512x512 and 256x256 A spatial light modulator (SLM) is an electrically programmable device that modulates light according to a fixed spatial (pixel)

More information

Keysight N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet

Keysight N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet Keysight N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet 02 Keysight N1913A and N1914A EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet

More information

R&S FPL1000 Spectrum Analyzer Specifications

R&S FPL1000 Spectrum Analyzer Specifications R&S FPL1000 Spectrum Analyzer Specifications year Data Sheet Version 02.00 CONTENTS Definitions... 3 Specifications... 4 Frequency... 4 Sweep time... 5 Resolution bandwidths... 5 Level... 6 Measurement

More information

Agilent 86100B Wide-Bandwidth Oscilloscope Technical Specifications

Agilent 86100B Wide-Bandwidth Oscilloscope Technical Specifications Agilent 86100B Wide-Bandwidth Oscilloscope Technical Specifications Three instruments in one A digital communications analyzer, a full featured wide-bandwidth oscilloscope, and a time-domain reflectometer.

More information

SPATIAL LIGHT MODULATORS

SPATIAL LIGHT MODULATORS SPATIAL LIGHT MODULATORS Reflective XY Series Phase and Amplitude 512x512 A spatial light modulator (SLM) is an electrically programmable device that modulates light according to a fixed spatial (pixel)

More information

Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules. Data Sheet

Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules. Data Sheet Keysight Technologies Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules Data Sheet 02 Keysight Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet

More information

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V 18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V With its characteristics of power stability whatever the load, very fast response time when pulsed (via external modulated signal), low ripple,

More information

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note Basic RF Amplifier Measurements using a R&S ZNB Analyzer and SMARTerCal Mark Bailey 2013-03-05, 1ES, Version 1.0 Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal.

More information

R&S ZNL Vector Network Analyzer Specifications

R&S ZNL Vector Network Analyzer Specifications R&S ZNL Vector Network Analyzer Specifications year Data Sheet Version 01.00 CONTENTS Definitions... 3 Specifications... 4 Measurement range... 4 Measurement speed... 5 Measurement accuracy... 6 Effective

More information

Calibrating attenuators using the 9640A RF Reference

Calibrating attenuators using the 9640A RF Reference Calibrating attenuators using the 9640A RF Reference Application Note The precision, continuously variable attenuator within the 9640A can be used as a reference in the calibration of other attenuators,

More information

R&S FSMR Measuring Receiver Specifications

R&S FSMR Measuring Receiver Specifications Test & Measurement Data Sheet 09.00 R&S FSMR Measuring Receiver Specifications CONTENTS Specifications... 3 Frequency...3 Measuring receiver... 3 Frequency counter...3 RF power...4 RF level (tuned receiver)...5

More information

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 Triarchy Technologies Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013 Triarchy Technologies,

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

Agilent N5120A Baseband Studio for CPRI RE Test

Agilent N5120A Baseband Studio for CPRI RE Test Agilent N5120A Baseband Studio for CPRI RE Test Technical Overview The Agilent N5120A Baseband Studio for CPRI RE Test is the first commercially available CPRI radio equipment test solution The N5120A

More information

R&S FSW-K144 5G NR Measurement Application Specifications

R&S FSW-K144 5G NR Measurement Application Specifications R&S FSW-K144 5G NR Measurement Application Specifications Data Sheet Version 01.00 CONTENTS Definitions... 3 Specifications... 4 Overview... 4 Assignment of option numbers to link modes... 4 Supported

More information

DT3130 Series for Machine Vision

DT3130 Series for Machine Vision Compatible Windows Software DT Vision Foundry GLOBAL LAB /2 DT3130 Series for Machine Vision Simultaneous Frame Grabber Boards for the Key Features Contains the functionality of up to three frame grabbers

More information

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies 1 Table of Contents Chapter

More information

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR Revision 1.00 February 27, 2015 Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR 1 Table of Contents 1.

More information

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active

More information

THE RGB 320 ARCHITECTURAL SERIES INTERFACE SYSTEM. Virtual interfacing. Show me button. Remote connection. Two gang face plates

THE RGB 320 ARCHITECTURAL SERIES INTERFACE SYSTEM. Virtual interfacing. Show me button. Remote connection. Two gang face plates Virtual interfacing Show me button Remote connection Two gang face plates RS-232/422 controllable RGsB, RsGsBs, RGBS and RGBHV Video & audio level adjustments 220 MHz (-3db) bandwidth Aesthetic appeal

More information

SSA3000X Series Spectrum Analyzer

SSA3000X Series Spectrum Analyzer SSA3000X Series Spectrum Analyzer SSA3000X Spectrum Analyzer Data Sheet Features and Benefits SSA3032X SSA3021X All-Digital IF Technology Frequency Range from 9 khz up to 3.2 GHz -161 dbm/hz Displayed

More information

LPT-2250 Spectrum Analyzer Operation Manual

LPT-2250 Spectrum Analyzer Operation Manual LPT-2250 Spectrum Analyzer Operation Manual 1999 LP Technologies, Inc. All rights reserved Document # 070-1500-0001, Rev E Table of Contents 1.0 GENERAL DESCRIPTION AND FEATURES...3 2.0 USAGE PRECAUTIONS

More information

Tests on 3G-Base Stations to TS with FSIQ and SMIQ

Tests on 3G-Base Stations to TS with FSIQ and SMIQ Products: FSIQ, SMIQ Tests on 3G-Base Stations to TS 25.141 with FSIQ and SMIQ This application note describes how to measure the various WCDMA signals which are used for transmitter tests on FDD base

More information

MTS/T-BERD 8000 Platform

MTS/T-BERD 8000 Platform Key Features New optical design for field applications 50% reduction in size and weight for true OSNR measurements in ROADM networks Full spectral range of 1250 to 1650 nm for DWDM and CWDM testing High-resolution

More information

L-Band Block Up- and Downconverter Indoor / Outdoor

L-Band Block Up- and Downconverter Indoor / Outdoor Visit us at www.work-microwave.com L-Band Block Up- and Downconverter Single / Dual / Triple Band Single / Dual Channel S-, C-, X-, Ku-, K- (DBS), Ka-band (Q/V-band available on request) VSBU / VSBD Type

More information

High Speed Data Acquisition Cards

High Speed Data Acquisition Cards High Speed Data Acquisition Cards TPCE TPCE-LE TPCE-I TPCX 2016 Elsys AG www.elsys-instruments.com 1 Product Overview Elsys Data Acquisition Cards are high speed high precision digitizer modules. Based

More information

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications R&S TC-TA18 cross-polarized Vivaldi test antenna, R&S TC-CA6 linear-polarized communications antenna Data

More information

Model RTSA7550 Specification v1.1

Model RTSA7550 Specification v1.1 Model RTSA7550 Specification v1.1 Real-Time Spectrum Analyzers - 9 khz to 8/18/27 GHz Featuring Real-Time Bandwidth (RTBW) up to 160 MHz Spurious Free Dynamic Range (SFDR) up to 100 dbc Small form-factor,

More information

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer Application Note Introduction High-power devices are common building blocks in RF and microwave communication

More information

MICROWAVE MEASURING INSTRUMENTS

MICROWAVE MEASURING INSTRUMENTS ICROWAVE SYSTE ANAYZER E453//, E538// 70 Hz band 70/140 Hz band Custom-made product OPTION The E453 and E538 series are used to measure the transmission line characteristics in the BB and IF bands in terrestrial

More information

R&S RSC Step Attenuator Where precise signal levels count

R&S RSC Step Attenuator Where precise signal levels count Test & Measurement Product Brochure 01.00 Step Attenuator Where precise signal levels count Step Attenuator At a glance The is a switchable, mechanical step attenuator. It is available in various models

More information

Agilent ESA Series Spectrum Analyzers

Agilent ESA Series Spectrum Analyzers Agilent ESA Series Spectrum Analyzers Demonstration Guide and Application Note This demo guide is a tool to gain familiarity with the basic functions and features of the Agilent Technologies ESA-L series

More information