Volition TM RJ45 K5e Jacks
|
|
- Merilyn Jefferson
- 6 years ago
- Views:
Transcription
1 Volition TM RJ45 K5e Jacks Part of our 3M Volition Network Solutions, the new K5e range is our ultimate Category 5e hardware component (ISO/IEC 11801, EN and ANSI/TIA/EIA-568). The K5e jack is a core product in our system solution, which includes a comprehensive range of patch panels, sokkets and faceplates, Category 5e patch cords and cables. The K5e jack offers the best margin over Class D / Category 5e link standards. RJ45 K5e Jacks UTP The RJ45 K5e jack is available in three different formats: UTP FTP with drain wire STP 360 braid or foil connection A unique design: Tool-less jack: Re-usable Shallow Depth, Cable Entry from top or bottom: Benefits Easy and quick to install Fast reliable connection in record time: all 8 copper conductors are effortlessly wired in a single operation Quality of connection by design: not dependant on tool condition or operator skills, just listen for the click Consistent results: the length of untwisted pairs and the length between the end of the conductor and the IDC contacts are always kept to a minimum, by design If a wiring mistake is made there is no need to use a new jack No time wasted waiting for another delivery Easier cable management More space and flexibility to ensure the cable minimum bend radius is never compromised - Allows a wide range of cable routing options - Can be used with low profile trunking and boxes UTP, FTP and STP 360 shielded versions have the same "one-click tool-less design: Accepts both solid conductors from AWG 26 to 22 and stranded conductors: Integral shutter: Solutions for all levels of EMC protection using the same accessories means less training Compatible with all cables on the market and enables jack to plug cables to be manufactured using stranded conductors (for use in open office architectures) Increased dust protection, especially during installation or in a dirty environment No additional shuttering required on faceplates Higher port density Allows direct mounting into floor boxes Protects jacks in the patch panel
2 Specifications - Cat 5e hardware component - IEC compliant - Integral shutter - Single forked contacts - Conductor diameter: 0,50 mm to 0,65 mm solid copper, 7x0,15 to 0,20 mm stranded cable - Sheath diameter: 1,6 mm max Technical characteristics - Lead-through resistance 17 mω < Resistance < 20 mω - Insulation resistance > 10 MΩ RJ-45 Category 5e Hardware test result (Typical values) Frequency Attenuation Return Loss NEXT pair to pair 100 MHz < 0.2 db 24 db 49 db Permanent Link 5e / Class D test result (Typical values) Attenuation NEXT ELFEXT Return Loss Value 17.9 db 52.6 db 35.4 db 25.2 db Margin 3.1 db 7.9 db 8.6 db 6.4 db Frequency 99.4 MHz 17.4 MHz 39.2 MHz 21.2 MHz Ordering Information Ref.-No. Volition RJ45 K5e Jack, Category 5e, UTP, white VOL-OCK5E-U UTP jacks are also available in blue, green, red, yellow, black, orange and almond Volition RJ45 K5e Jack, Category 5e, FTP, white and a ninth point to ensure the grounding continuity VOL-OCK5E-F Volition RJ45 K5e Jack, Category 5e, FTP white and metallic shield, metallic nose and tinned bronze cover shielded by reservible metal cover. Supplied with a fixing colar continuity VOL-OCK5E-S 3M and Volition are trademarks of the 3M Company. Quante is a trademark of Quante AG. Important Notice 3M does not accept reponsibility or liability, direct or consequential arising from reliance upon any information provided and the user should determine the suitability of the products for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M s liability for death or personal injury arising from its negligence. All questions of liability relating to 3M products are governed by the seller s terms of sale subject where applicable to the prevailing law. 3M Telecommunications Europe, Middle East & North Africa c/o Quante AG Carl-Schurz-Straße Neuss Germany If any goods supplied or process ed by or on behalf of 3M prove on inspection to be defective in material or workmanship, 3M will (at its option) replace the same or refund to the Buyer the price of the goods or services. Except as set out above, all warranties and conditions, whether express or implied, statutory or otherwise are excluded to the fullest extent permissible at law. Tel.: ++49 (0)2131 / Fax: ++49 (0)2131 / Internet: Rights reserved to make technical alternations. Dr.Nr / pdf
3 Volition TM RJ45 K6 Jacks Part of our 3M Volition Nework Solutions, the new K6 range is our ultimate Category 6 hardware component (ISO/IEC 11801,EN and ANSI/TIA/EIA-568). The K6 jack is a core product in our system solution, which includes a comprehensive range of patch panels, sockets and faceplates, Category 6 patch cords and cables. The K6 Jack offers the best margin over Class E / Category 6 link standards. RJ45 K6 Jacks The RJ45 K6 jack is available in three different formats: - UTP - FTP with drain wire - STP 360 braid or foil connection A unique design: Tool-less jack: Re-usable: Shallow Depth, Cable Entry from top or bottom: UTP, FTP, and STP, 360 shielded versions have the same "one-click" tool-less design: Accepts both solid conductors from AWG 26 to 22 and stranded conductors: Integral shutter: Benefits Easy and quick to install Fast reliable connection in record time: all 8 copper conductors are effortlessly wired in a single operation Quality of connection by design: not dependant on tool condition or operator skills, just listen for the click Consistent results: the length of untwisted pairs and the length between the end of the conductor and the IDC contacts are always kept to a minimum, by design If a wiring mistake is made there is no need to use a new jack no time wasted waiting for another delivery Easier cable management More space and flexibility to ensure the cable minimum bend radius is never compromised - Allows a wide range of cable routing options - Can be used with low profile trunking and boxes Solutions for all levels of EMC protection using the same accessories means less training Compatible with all cables on the market and enables jack to plug cables to be manufactured using stranded conductors (for use in open office architectures) Increased dust protection, especially during installation or in a dirty environment No additional shuttering required on faceplates Higher port density Allows direct mounting into floor boxes Protects jacks in the patch panel
4 Specifications - Category 6 hardware component - IEC compliant - Integral shutter - Single forked contacts - Conductor diameter: 0,50 mm to 0,65 mm solid copper, 7 x 0,15 to 0,20 mm stranded cable - Sheath diameter: 1,6 mm max Technical characteristics - Lead-through resistance 17 mω < Resistance <20 mω - Insulation resistance > 10 MΩ RJ-45 Category 6 Hardware test result (Typical values) Frequency 100 MHz 200 MHz 250 MHz Attenuation < 0.2 db < 0.2 db < 0.3 db Return Loss 24 db 18.5 db 16 db NEXT pair to pair 58 db 50 db 47.5 db Permanent Link Class E test result (Typical values) Attenuation NEXT ELFEXT Return Loss Value 29.5 db 43.4 db 22.2 db 25.3 db Margin 1.0 db 8.1 db 5.9 db 4.3 db Frequency 250 MHz 250 MHz 250 MHz 4 MHz Ordering Information Ref.-No. Volition, RJ45 K6 Jack, Category 6, UTP, white VOL-OCK6-U UTP jacks are also available in blue, green, red, yellow, black, orange and almond Volition, RJ45 K6 Jack, Category 6, FTP, white Ninth point for grounding continuity VOL-OCK6-F Important Notice 3M does not accept reponsibility or liability, direct or consequential arising from reliance upon any information provided and the user should determine the suitability of the products for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M s liability for death or personal injury arising from its negligence. All questions of liability relating to 3M products are governed by the seller s terms of sale subject where applicable to the prevailing law. Volition, RJ45 K6 Jack, Category 6, STP, white and metallic shield Metallic nose and tinned bronze cover shielded by a reversible metal cover Supplied with a fixing collar 3M and Volition are trademarks of 3M. Quante is a trademark of Quante AG. 3M Telecommunications Europe, Middle East & North Africa c/o Quante AG Carl-Schurz-Straße Neuss Germany VOL-OCK6-S If any goods supplied or process ed by or on behalf of 3M prove on inspection to be defective in material or workmanship, 3M will (at its option) replace the same or refund to the Buyer the price of the goods or services. Except as set out above, all warranties and conditions, whether express or implied, statutory or otherwise are excluded to the fullest extent permissible at law. Tel.: ++49 (0)2131 / Fax: ++49 (0)2131 / Internet: Rights reserved to make technical alternations. Dr.Nr / pdf
5 3M Volition K6ASN RJ45 STP Jack Datasheet 3M Volition K6ASN RJ45 STP Jack, New Design, with three cable entries The new K6ASN RJ45 Jack is a key component of the Volition Category6A/Class EA system, fully compliant with Category 6A ISO/IEC, EN and TIA standards for hardware performance, confirmed by multiple independent lab certifications (Delta and GHMT). Its top-class electrical performance guarantees consistently high headroom at any link length, down to 3m links. The unique three cable entry points make it possible to install the jack anywhere. The 360 shielding of the jack facilitates a worry-free Class EA / Category 6A installation. The traditional 3M one click design allows an easy, tool-less termination on Volition Category 6A F/UTP, U/FTP, F/FTP and Category 7 S/FTP cables. 3M Volition K6A RJ45 STP Jack Applications Standards - IEEE G BASE-T - ISO/ IEC Edition 2, Am PoE IEEE 802.3at - ISO/ IEC EN ANSI/ TIA/ EIA-568-C IEC Three cable entry points Category 6A compliant according to ISO/IEC standard Category 6A compliant according to TIA standard Certified by Delta and GHMT 360 Metallic shielding Tool-less termination Re-usable jack No untwisting of pairs before termination Connector can be terminated with both solid and stranded wire Integrated automatic dust shutter Compact size POE+ compliant Benefits Less cable bending required - better compliance with minimum bend radius. Allows selection of the cable entry according to the best cable path: floor, ceiling, duct, patch panel. Out performs standards, high reliability - positive permanent link headroom down to 3m links. Assurance that the 3M K6ASN Jack complies with standards. Total immunity to alien crosstalk, by design - no need to test ANEXT on the field, dramatic reduction in testing time. No specialised tools required - termination performance independent of tool quality. No additional expenditure on tools - No delays caused by lack of tools or damaged tools. If a wiring mistake is made there is no need to use a new jack - no time wasted waiting for another delivery. Minimised stripping length - very limited pair untwist - pairs kept together. Easy fitting of the pairs without threading through a wire guide. Enables jack to plug cables to be manufactured using stranded conductors (for use in open office architectures and consolidation points). Increased dust protection, especially during installation or in a dirty environment. No additional shuttering required on faceplates. Allows direct mounting into floor boxes - protects jacks in the patch panels. Same format as other 3M RJ45 connectors. Easy mounting onto: - 3M branded face plates, patch panels, adaptors and other accessories. Compact size allows easier cable management and more space to ensure the cable minimum bend radius is never compromised. Supports PoE plus applications according to latest IEEE standards.
6 Specifications Plated copper shielding as protection against the effects of alien crosstalk Plated copper cap for the rear of the jack Plated copper cable cap is adaptable to allow for top, bottom or rear cable entry Metal braid on cap gives 360 connection to cable screen Tool-less connection of all eight wires at one time by closing the metal locking wings Wire holder is labelled with both 568A and 568B wire maps Single forked contacts Integrated shutter White colour (RAL 9010) Technical characteristics Conforms with hardware performance parameters of Category 6A ISO and Category 6A TIA Conductor diameter solid wires: 0,50 to 0,65 mm stranded wires: 7 x 0,15 to 0,20 mm Maximum diameter of wire insulation: 1,6 mm Lead through resistance: < 200 mω Insulation resistance: Protection contacts: RI > 500 MΩ 1,6 µm gold Electrical parameters Margins "Permanent Link" Margins "Channel" (typical values) Amendment 2 ISO/IEC Amendment 1 ISO/IEC nd edition: nd edition:2008 "Class E A " "Class E A " NEXT 5 db 5.5 db PSNEXT 7.5 db 7 db ACR-F 16 db 12 db PSACR-F 17.5 db 13.5 db Return Loss 3 db 6 db Ordering Information 3M Volition RJ45 K6A STP Jack Supplied with a cable tie to hold the connector braid onto the cable shielding Ref. No. VOLOCK6ASN8 VOLOCK6ASNV (bulk) Important Notice The details contained in this literature have been carefully prepared from information available to 3M at the time of its production. However, it is not intended to be relied upon for purposes of product specification and you should contact your sales representative if specification details are required. Because of the wide variety of processes and conditions in which these products may be used, the user should first carry out tests to determine the suitability of the products for the particular use intended. All questions of warranty and liability relating to 3M products are governed by the selling 3M subsidiary's Terms of Sale subject where applicable to the prevailing law. 3M and Volition are trademarks of the 3M company. 3M Telecommunications Europe, Middle East & Africa c/o 3M Deutschland GmbH Carl-Schurz-Straße Neuss Germany Tel.: ++49 (0)2131 / Fax: ++49 (0)2131 / Rights reserved to make technical alternations. Internet: REV. 0 Edition 12/2012
Volition TM Category 5e cable 100 Ω, FTP
Volition TM Category 5e cable 100 Ω, FTP Part of the 3M Volition Network Solutions, this 250 MHz FTP cable is a Category 5e TIA / EIA 568 and ISO 11801 and EN 50173 Class D compliant. The green sheath
More informationLCS2 Cat. 6 RJ 45 Patch panels and units
87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2
More informationCATEGORY 6 CABLING SOLUTIONS
With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality
More informationLCS 2 RJ 45 Cat. 6A HD panels and units
87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1
More informationCATEGORY 5e CABLING SOLUTIONS
With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the
More informationCATEGORY 6A CABLING SOLUTIONS
10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Premium Line Category 6A Cabling Solutions
More informationDescription: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.
Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product
More informationPREMIUM 5e F/UTP PRODUCTS
Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been
More informationCATEGORY 6A CABLING SOLUTIONS
10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Need of 10 Gigabit Service Application as
More informationLEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION
LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION 14 LCS 2 Copper A complete system for higher performance Connectors See pages 16 to 19 LCS 2 copper Patch panels See pages 21 to
More informationCopper Solution Contents Cabinets Fiber Optic Solution
Contents Copper Solution Category 6A + Cabling Solutions Cat.6A + 1000MHz S/FTP Installation Cable A1 Cat.6A + S/FTP Patch Cord A2 Cat.6A + 90 Fully Shielded Die-casting Keystone Jack A3 Modular German
More informationMagic Patch Patch Leads & Accessories
Magic Patch Patch Leads & Accessories T: 01376 346600 F: 01376 346620 www.connectixcablingsystems.com Issue 1.1 Magic Patch Cabling Systems TM Magic Patch Connectix Cabling Sytems TM range of patch leads,
More informationtechnicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link
technicalreport Data communication technology 09/2018 Classic structure 2-connector link Ethernet transmission with twisted pair cables Limiting factors for links > 100 m Example structure of a 2-connector
More informationRobert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions
Robert Burén Product Manager 10G Solutions Nexans Cabling Solutions 1 10 Gigabit Ethernet.Performance 30 GByte can be transmitted within 24 seconds Example: MRI-scan size is 30GB as average A memory device
More informationPre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports
RJ45 - Cat. 6A Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports Compatible with FO trunks Modern data centre trunk solution in modular cassette technology Pre-terminated
More informationSTRUCTURED CABLING SYSTEMS (SCS)
STRUCTURED CABLING SYSTEMS (SCS) ModSecur - Structured Cabling Systems (SCS) A Structured Cabling System (SCS) is the backbone of any building, campus or site communication infrastructure. The sharp growth
More informationProduct information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated
Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s
More informationLANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU
LANmark PCB patch panel, 1HU INSTALLATION GUIDE LANmark PCB patch panel, 1 HU Document information Document reference Release September 2001 Published by Contact address BRO-009 LANmark PP 1HU 0701 Nexans
More information10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP
0G A Combining 0 Gb/s performance with the security, noise immunity and pathway space maximisation of a screened cabling system, Siemon s end-to-end solution represents the cutting edge of augmented category
More informationCompact Module. Category 6 FTP Cabling System
Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with
More informationFrequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m
Cat.5e 4 Pair UTP Cable Application: Voice ISDN 10Base T(IEEE 802.3) Fast Ethernet(IEEE802.3u) 100Vg-AnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TP-PMD(ANSI X3T9.5) 100Base-T Ethernet(IEEE 802.5) 155/622
More informationBTNS TM. FTP Compact Module
FTP Compact Module BTNS Category 6A FTP Compact Modules have been designed to provide the exceptional performance required to support extremely high speed applications such as 10-Gigabit Ethernet. Category
More informationHARTING Ethernet cabling cables and connectors, 4 wire
Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation
More informationTender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*
Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:
More informationCAT6Plus System. Brand-Rex Limited
Brand Rex introduces it's New CAT6Plus Cabling Solution, designed to deliver an optimum performance cabling system. All products in the CAT6Plus system have 3rd party approval* and therefore either meet
More information10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System
10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System Next-Generation Category 6A UTP Cabling System Drivers for 10 GbE Aggregation of Gigabit Links Server Consolidation and
More informationUC Copper / Fibre summary on USPs. Zoran Borcic, Axel Koplev
UC Copper / Fibre summary on USPs Zoran Borcic, Axel Koplev Draka UC Cable Key Elements UC Copper Range Shielded solutions Focus on Cat. 6 A / 7/ 7 A Prepare for Cat.8 / 40G Patent based design Cat. 6
More informationHighBand 25. TrueNet Category 6 Solutions
HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution
More information3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper
3M Volition Network Solutions introduces Category 5e (Cat. 5e) copper cabling system to complement its leading fiber optic structured cabling system. Customers can now enjoy a single source of supply and
More informationTB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)
TB806AUX / Cat.6A UTP Keystone Jack (Auto press-fit) Cable holder with Strain Relief (SR) function: secure the cable with cable tie, and not wiggle to affect the termination and transmission. Cap: easy
More informationLCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS
LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS Global strength built on local knowledge Legrand is the global specialist in electrical
More informationLAN Cabling Systems Copper
LAN Cabling Systems Copper Table of content About Nexans 3 Copper 4 Essential Cat 5e Cable 5 LANmark-6 Cable 7 LANmark-6A Cable 9 LANmark-7 Cable 11 LANmark-7A Cable 13 Legal Notice 14 8/20/11 - http://www.nexans-fi.com
More informationHeadquarters Middle East & Africa Asia Premium-Line Systems GmbH Rosenheimer Str. 89 D-83064 Raubling, Germany Premium-Line Systems FZC SAIF Zone P.O. Box 7869 Sharjah, U.A.E Premium-Line Asia Ltd 12-9
More informationINFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1
INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1 WWW.INFRASTONE.COM Contents BLACKSTONE CAT6A U/UTP channel performance Introduction BLACKSTONE CAT6A U/UTP channel
More informationGenSPEED Category 5e Cables 3
Datacom GenSPEED Category 5e Cables 3 GenSPEED Category 5e cables are available in a wide variety of performance levels and constructions. With many options to pick from, you can select the GenSPEED Category
More informationHigh Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions
High Density Block BRCP HD BRCP- 128/192/256 pair Installation Instructions Product Introduction The BRCP block is the latest generation of MDF terminal blocks developed by 3M, specifically designed for
More informationTB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)
TB876BSX-3WH / Cat.6A STP Keystone Jack (Auto press-fit) Copper braid can be fully contacted and covered for 23-26 AWG solid wire. Press-fit process. 100% RoHS compliant, without soldering. Unique design
More informationInformation & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008
Information & Communications Technology Group Standards June 2008 Appendix F UTP cabling Version 1.1 Appendix F UTP cabling 1. Introduction This Section details the required standards for Unshielded Twisted
More informationDINTEK LAN Cabling Systems
4 Pair UTP Cable Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550
More informationGigaSPEED X10D F/UTP. SYSTIMAX solutions
GigaSPEED X10D F/UTP SYSTIMAX solutions Contents Introduction 3 SYSTIMAX GigaSPEED X10D F/UTP channel performance 3 SYSTIMAX GigaSPEED X10D 91 series F/UTP cable 5 SYSTIMAX GigaSPEED X10D G10FP F/UTP 6
More informationIndoor cabling LAN Cabling Systems
Indoor cabling LAN Cabling Systems Table of content Nexans 6 Symbols 7 LAN Cabling Systems 8 Copper 9 Category 5e 10 Essential Cat 5e Cable 11 Essential Patch Panels 14 Essential Outlet Modules 16 Essential
More information6-Connector- Channel-Link Class E A (STP)
6-Connector- Channel-Link Class E A (STP) 1 MAXIMUM FLEXIBILITY FOR YOUR NETWORK Connection Module DN-93907-1 Network Cabinet DN-19 42U-8/8-1 Patch Cable DK-1644-A-XXX Installation Cable DK-1741-VH-X Wall
More informationGIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH
GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH Product Type LAN Cable Product Family Construction GigaLan Augmented RoHS Compliant Category 6A F/UTP LSZH General Characteristics Features Installation
More informationTable of Contents. Open Matrix System (OMS) 1-2
Company Profile Addison cabling system originated as a cabling solution produced and marketed by Caledonian Cables Ltd located at Sussex, England. Founded in 1978, Caledonian Cables originally entered
More informationWhat really changes with Category 6
1 What really changes with Category 6 Category 6, the standard recently completed by TIA/EIA, represents an important accomplishment for the telecommunications industry. Find out which are the actual differences
More information10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP
0G A is Siemon s advanced, end-to-end augmented category UTP structured cabling system, designed to meet or exceed all 0GBASE-T performance requirements, including alien crosstalk. Siemon s full channel
More informationSECTION COMMUNICATIONS HORIZONTAL CABLING
(NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 - GENERAL 1.1 SECTION
More informationConnect with the industry s best CAT6 and CAT5e channel solutions!
Connect with the industry s best CAT6 and CAT5e channel solutions! Our CAT6 and CAT5e channel solutions far exceed the TIA/EIA specifications performance standards! To ensure consistent and continuing
More informationHeadquarters Middle East & Africa Asia Premium-Line Systems GmbH Rosenheimer Str. 89 D-83064 Raubling, Germany Premium-Line Systems FZC SAIF Zone P.O. Box 7869 Sharjah, U.A.E Premium Line Asia Ltd. 12-9
More informationPre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017
Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library
More informationC6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A
C6 A modul and C6 A modul K The new connection system for a wide variety of applications of course with Cat.6 A Intelligent system solution for structured cabling Nowadays the need for high data transfer
More informationSECTION TESTING OF COPPER CABLES
SECTION 27 08 13 TESTING OF COPPER CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationCategory 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.
27 08 00 Certification and Commissioning of Communication Systems (Revision date: 7/3/12) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are
More informationCAT5E NETWORK PATCH LEADS
CAT5E NETWORK PATCH LEADS Cat5e UTP Patch Leads - 50 MHz The Category 5 enhanced UTP patch leads conform to the TIA/EIA-568-B specification. Cables are pre-made to the T568A pinout specification with tangle
More informationQuickreference: Cat.6 / Class E shielded. Horizontal floor cabling subsystem with shielded twisted pair technology
Quickreference: Cat.6 / Class E shielded Horizontal floor cabling subsystem with shielded twisted pair technology Version: September 2015 System Overview SYSTEM OVERVIEW The shielded Cat.6 / Class E product
More informationBelden IBDN System 10GX Enabling Technologies
Belden IBDN System 10GX Enabling Technologies by Paul Kish Director, Systems and Standards Revision 1 November 2008 Belden Belden IBDN System 10GX Enabling Technologies 1/17 Introduction The IEEE 802.3an
More informationCalifornia Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationFUTURE PROOF YOUR CONNECTIONS
FUTURE PROOF YOUR CONNECTIONS DataMax Commercial Data Cable The Strongest Link. When you choose Quabbin Wire and Cable you are not only selecting a premier cable, you are also investing in productivity
More informationSTRUCTURED CABLE SYSTEM (SCS)
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationQuickreference: Cat.6A EL / Class EA shielded. Horizontal floor cabling subsystem with shielded twisted pair technology
Quickreference: Cat.6A EL / Class EA shielded Horizontal floor cabling subsystem with shielded twisted pair technology Version: June 2017 System Overview CAT.6 A EL / CLASS E A SYSTEM OVERVIEW The shielded
More informationEffective earthing of screened cables
NOVEMBER 2006 Effective earthing of screened cables All metallic containment items, other extraneous metalwork and the screens of telecommunications cables in an information technology environment must
More informationMIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project
1.1.0 GENERAL The purpose of this specification is to establish a requirement for the installation of a voice, video and data cable network. The cable (copper), wire, hardware, equipment racks, jumpers,
More informationNEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables
NEMA Standards Publication Performance Standard for Twisted Pair Premise Voice and Data Communications Cables Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752
More informationNEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables
NEMA Standards Publication WC 63.1-2005 Performance Standard for Twisted Pair Premise Voice and Data Communications Cables Published by: National Electrical Manufacturers Association 1300 North 17th Street,
More informationSMART CLASSix 48 UTP Patch Panels (with patching switches) -
Features Front-mounted Patching Switches connect ports internally, dramatically reducing the need for patch cords Compatible to Unshielded Twisted Pairs (UTP) cabling systems High performance panel that
More information3M Distribution Box (DDB)
3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure
More informationHD1-DX HDMI Extender
. HD1-DX HDMI Extender Quick Reference & Setup Guide Magenta Research 128 Litchfield Road, New Milford, CT 06776 USA (860) 210-0546 FAX (860) 210-1758 www.magenta-research.com MAGENTA HD1-DX HDMI EXTENDER
More informationPart Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable
Part Number: 7965ENH.001000 Category 6 Nonbonded-Pair ScTP Cable Product Description CAT6 (250MHz), 4-Pair, U/UTP Unshielded, Premise Horizontal Cable, 23 AWG solid bare copper conductors, Polyethylene
More informationAbout Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11
Table of contents About Nexans 3 About Berk-Tek 4 LANmark-1000 Cat 6 UTP 5 LANmark-1000 Category 6 Plenum 6 LANmark-1000 Category 6 Riser 11 LANmark-1000 Category 6 Patch 16 21 7/10/07 - http://www.berktek.com
More informationCoastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents
PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2
More informationCategory 5e F/UTP Euroclass D ca Cables
Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 APPLICATION The Brand-Rex GPF D ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level D ca
More informationLANmark. Copper Cabling Solutions
LANmark Copper Cabling Solutions Edition 01/03/2001 Copyright Nexans 2001 Subject to change without prior notice. In this publication, no mention is made of rights with respect to trademarks or tradenames
More informationBelden IBDN System 10GX The next level of cabling performance
Belden IBDN System 10GX The next level of cabling performance by Paul Kish Director Belden IBDN Systems and Standards Introduction There is a new standard under development in the IEEE 2.3an task force
More informationClarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.
Clarity Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS. Center Tuned Components Higher Signal-to- Noise Ratio Optimal Mated
More informationDo you know if your Cat. 6 patch cord has been tested according to standards?
White Paper 02. Juli 2002 Andreas Clauser Hauptsitz Binzstrasse 31 CH-8622 Wetzikon Tel +41 1 933 8375 Fax +41 1 930 49 41 Internet www.rdm.com Do you know if your Cat. 6 patch cord has been tested according
More informationHD-One DX/DX500 HDMI Extender
HD-One DX/DX500 HDMI Extender User Manual Version 2.0 tvone 2791 Circleport Drive, Erlanger, KY 41018, USA. Americas: 859-282-7303 EMEA: +44 (0) 1843 873322 Email: tech.usa@tvone.com www.tvone.com CSG-DX-500
More informationHD1-LX HDMI & IR Extender
. HD1-LX HDMI & IR Extender Quick Reference & Setup Guide Magenta Research 128 Litchfield Road, New Milford, CT 06776 USA (860) 210-0546 FAX (860) 210-1758 www.magenta-research.com MAGENTA HD1-LX HDMI
More informationC6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A
C6Amodul and C6Amodul K The connection system for a wide variety of applications of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates
More informationMulti-Media Installation Guide
Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.
More informationInstructions. Cable with Armor F CAUTION. October Rev A
3M Single Conductor Accessory Breakout Kits (BOK's) for use with 3M Cable Accessories (Terminations, T-Bodies and Push-On Elbows) For Use With Single Conductor Accessories On Three-Core Conductor Cables
More informationMSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited
MSF1000 MSF Radio Time Code Receiver User Manual Version 1.1 World Time Solutions World Time Solutions Limited COPYRIGHT 2011-2014 World Time Solutions Limited. All Rights Reserved. All information contained
More informationREQUEST FOR PROPOSAL FOR Supply and Installation UTP Network in the following location
REQUEST FOR PROPOSAL FOR Supply and Installation UTP Network in the following location General Scope of Work: Supply and Installation UTP Network in the following location. Locations of Installation: Computer
More informationGIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)
GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP) Product Type LAN Cable Product Family Construction GigaLan RoHS-2 Compliant Category 6 U/UTP (unshielded) LSZH General Characteristics Features Installation Environment
More informationThe development of the Z-MAX line began with a simple goal design and build the best RJ-45 based cabling solution period.
Z-MAX NETWORK CABLING SOLUTIONS Siemon s Z-MAX Network Cabling Solutions The development of the Z-MAX line began with a simple goal design and build the best RJ-45 based cabling solution period. And best
More informationPeak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide
GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information
More informationClass E A / Cat.6A Screened Coupler
Class E A / Cat.6A Screened Coupler Patented Qualified Class E A / Cat.6A (500MHz) of ANSI/TIA-568-C.2 IEC 60603-7-51 AMD 2,Class E A CENELEC EN 50173-1 Specification Specification: Qualified Screened
More informationbtnet new products Modular and preloaded patch panels btnet
btnet new products Modular and preloaded patch panels 128 btnet content 130 General characteristics Catalogue 132 UTP and FTP cable 134 Patch panel and cord 135 Pop-up and floor box 136 Fiber optic BTNET
More informationEuropean Product Catalog2009 AMP NETCONNECT Building Networks
European Product Catalog2009 AMP NETCONNECT Building Networks AMP NETCONNECT Structured Cabling Solutions for Enterprise Networks The Foundation of Your Company s Network Table of Contents 1 Unshielded
More informationMX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap
MAX 5e UTP Modules MAX 5e modules exceed category 5e performance with component and channel performance to 60 MHz. These modules offer all the functional advantages of our MAX 6 modules in a variety of
More informationGPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited
GPS000 GPS Time Receiver System User Manual Version. World Time Solutions World Time Solutions Limited COPYRIGHT 0-0 World Time Solutions Limited. All Rights Reserved. All information contained within
More informationGenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk
GenSPEED A Cables GenSPEED 10 MTP A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk 10 MTP unshielded-twisted pair (UTP) design provides industry-leading protection from external
More informationPreferred ordering guide for NETCONNECT
Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A
More informationSolutions for Electronic Specialty Markets (ESM)
3M Worldwide : United States : Electronics Manufacturing Solutions for Electronic Specialty Markets (ESM) Product Catalog for Electronic Specialty Markets 3M Electronic Specialty Markets - New Product
More informationSolarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China
www.solarstar-elec.com.cn Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China 518110 Tel/Fax:+86-755-83178592 info@solarstar-elec.com.cn www.solarstar-elec.com.cn
More informationSECTION TESTING, IDENTIFICATION AND ADMINISTRATION
PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification
More informationRJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.
insertions Contact set constructed of phosphor bronze Category 6 modular keystone jack - Blue - 1/bag Article Number: 852-25065 Part Number: Type: RJ45FC6 Base Data Part No. Type Color Features RJ45FC6
More informationUSER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH
USER GUIDE AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH Electromagnetic Compatibility (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
More informationRFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH
1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements
More informationExtender for HDMI over one CAT5
1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
More informationSECTION Structured Cabling Systems
SECTION Structured Cabling Systems DuraPort Industrial Connectivity Products 1 Structured Cabling Systems DuraPort Products Listing DURAPORT INDUSTRIAL CONNECTIVITY oisture, dust, corrosion, acids, detergents,
More information