PROFIBUS Installation suggestion

Size: px
Start display at page:

Download "PROFIBUS Installation suggestion"

Transcription

1 Data Sheet 10/ EN Rev. D PROFIUS Installation suggestion Ethernet Operate Engineer Control Linking Device PROFIUS P PROFIUS P Remote I/O F Field F Passive T-junction and active bus termination in the Non-Ex area Remote I/Os and field devices in Ex (Haz.) and Non-Ex area Redundancy concept with RLM01 /P Segment Coupler Shielding and grounding PROFIUS P PROFIUS P-layout example Fieldbus barrier in Ex (Haz.) area Passive 4-way junction in Non-Ex area PROFIUS P Fieldbus barrier in Ex (Haz.) area Passive T and 4-way junction in Non-Ex area

2 Overview PROFIUS - Installation suggestion Refer to PROFIUS Installation Guidelines : offers a wide range of IP IP 67 devices for Non-Ex and Ex (Haz.) areas. Optional cable bushing or SU-D socket at the housing for: Flowmeter, nalyzer, Process Controller, Electrical ctuator, DC Drives, Frequency Converter, Motor Management, Motor Starter, Remote I/O,... See data sheet - 10/ / EN

3 PROFIUS Installation suggestion Overview offers a wide range of IP IP 68 PROFIUS P devices for Non-Ex and Ex (Haz.) areas, incl. FISCO approval. Optional cable bushing or M12 plugs at the housing for: Temperature Transmitter, Pressure and Level Transmitter, Flowmeter, nalyzer, Positioner,... See data sheet - 10/ / EN 3

4 PROFIUS Installation suggestion - Passive T junction and active bus termination in the Non-Ex area Ethernet TCP/IP Master L T L T (Red.) (Option) (Option) (Option) Controller DP DP DP DP (Option) (Option) Linking Device DP/P: See page 11/12 Remote I/Os and s in Ex area: See page 6 L S L S U S Repeater DP/DP: for copper RS 485, FO, IR, See data sheets of the manufacturer U S s U S Description Catalog No. Data sheet 1 DTM undle & DTxxx (option) DS/DTM/DT200 - sset Vision - Device Management Tools for configuration and parameterization of /P and HRT field devices incl. open FDT interface. 2 ND121-NO (option) / /PC dapter for US 3 NDE230-NO - DP cable plug, 9-pos. SU-D / incl. switchable bus termination and programming connection SU-D, 12 Mit/s, IP 40 PINs: IN: 1 = RxD/TxD-N, 1 = RxD/TxD-P OUT: 2 = RxD/TxD-N, 2 = RxD/TxD-P 4 NDE220-NO - DP cable plug, 9-pos. SU-D / incl. switchable bus termination, 12 Mit/s, IP 40 PINs: IN: 1 = RxD/TxD-N, 1 = RxD/TxD-P OUT: 2 = RxD/TxD-N, 2 = RxD/TxD-P 5 cable, violet x 10/ NDC110-NO - 2 x 0.32 mm 2 (WG22/1), 65/330/1000 m 6 NDE210-NO - DP cable plug, 9-pos. SU-D / without bus termination, 12 Mit/s, IP 40 PINs: IN: 1 = RxD/TxD-N, 1 = RxD/TxD-P OUT: 2 = RxD/TxD-N, 2 = RxD/TxD-P 7 NDJ120-NO - DP T-junction, 1.5 Mit/s / x EMC cable bushing, without bus termination, aluminum housing, IP 66 (Shielding braid on ground via cable bushing) PINs: trunk cable (L T ): IN/OUT: = RxD/TxD-N, = RxD/TxD-P (lternative, not shown) NDJ130-NO - DP T-junction, 1.5 Mit/s / x EMC cable bushing, without bus termination, aluminum housing, IP 66 NDJ120-NOS - DP T-junction, 1.5 Mit/s / x cable bushing (plastic), without bus termination, stainless steel housing, IP 66 PINs: trunk cable (L T ): IN/OUT: = RxD/TxD-N, = RxD/TxD-P, S = shielding 8 NDE100-NE - DP cable plug / metal housing, M12, for Ex and Non-Ex areas, IP 67 PINs: 2 = RxD/TxD-N, 4 = RxD/TxD-P, 5 = shielding 9 NDJ122-NO - DP T-junction, 1.5 Mit/s / x EMC cable bushing, incl. active bus termination, aluminum housing, IP 66 (Shielding braid on ground via cable bushing) PINs: trunk cable (L T ): (L T ): IN: = RxD/TxD-N, = RxD/TxD-P Power-PINs: 24V = (+), 0V = (-) (lternative, not shown) NDJ132-NO - DP T-junction, 1.5 Mit/s / x EMC cable bushing, incl. active bus termination, aluminum housing, IP 66 NDJ122-NOS - DP T-junction, 1.5 Mit/s / x cable bushing (plastic), incl. active bus termination, stainless steel housing, IP 66 PINs: PINs: trunk cable (L T ): IN: = RxD/TxD-N, = RxD/TxD-P, S = shielding Power-PINs: 24V = (+), 0V = (-) Color coding: : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P - = green + - DC DC U S (24 V DC 10 m) M00540_EN ttention (valid for all pages): For the PIN coding the respective product data sheet is relevant! 4 10/ EN

5 PROFIUS Installation suggestion Limits and rules! When using the Fieldbus accessories: per PROFIUS Line (Line = Starting at the DP Master up to the last DP/P Slave) - approx. 4 up to 8 DP segments by Repeater (see data sheets of the Repeater) - recommended DP transfer rate kit/s - the slowest DP subscriber sets the transfer rate of the DP line - number of and P subscribers 126 (ddresses 0 125) per segment: - number of DP subscriber 32 (subscriber = device with / without PROFIUS address) - bus termination each at the beginning and the end of every DP segment necessary! - trunk cable length (L T ) see diagram (length depending on transfer rate) - spur cable length (L S ), at 1500 kit/s: L S 0.25 m, at > 1500 kit/s: L S = 0.00 m! - at 1500 kit/s and DP cable type : Total sum of all spur cable length (L S ) 6.60 m, trunk cable length (L T ) > 6.60 m, L total = L T + (Σ L S ) 200 m, max. 22 DP subscribers (= 6.60 m / (0.25 m m reserve)) L T /m EI 485 (RS485) y using copper cable Transfer rate 9.60 kit/s kit/s kit/s kit/s kit/s 500 kit/s 1500 kit/s 3 Mit/s 6 Mit/s 12 Mit/s it/s M00532_EN 10/ EN 5

6 - Remote I/Os and field devices in Ex (Haz.) and Non-Ex area PROFIUS Installation suggestion aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P- = green aaaa aaaa aaaa aaaa aaaa aaaa aaaa aaaa aaaa aaaa 1) ternative to increase the protocol stability: External active bus termination with S900- I914S at the end of the DP segment. 2) Number of field devices per DP Ex i segment are calculate explicitly and depend on the Repeater type, the DP cable, the s and the bus termination. You can find more information on the following page. 6 10/ EN

7 PROFIUS Installation suggestion Description (for page 6) Catalog No. Data sheets 1 S800 - Remote I/O System On request - DP / DPV1 bus up to 12 Mit/s, [Ex ia] - more information see Product Guide 3SE NDE210-NO - DP cable plug, 9-pos. SU-D / PINs: IN: 1 = RxD/TxD-N, 1 = RxD/TxD-P OUT: 2 = RxD/TxD-N, 2 = RxD/TxD-P NDE220-NO, NDE230-NO (lternative, not shown) 10/ DP cable plug, 9-pos. SU-D S900 - Remote I/O System On request 3DD010421Rxx01 - for Ex (Haz.) (Zone 1/2) and Non-Ex area, DP / DPV1 bus up to 1.5 Mit/s 3DD010437Rxx01 - More information how to build up the S900 System and limits see manual. (e.g.: number of S900/C220, Non-Ex or Ex (Haz.) zone 2, FO, redundancy, power supply filter,..) 4 S900-P910S - DP cable plug 3KDE175831L9100 3DD010421Rxx01-9-pos SU-D, blue, used for the Ex i DP cable, incl. switchable bus termination PINs: IN/OUT: = RxD/TxD-N, = RxD/TxD-P 5 S900-I914S - DP Repeater 3DH000649R1 On request - uild up in the Ex (Haz.) area, DIN rail mounted, RS485 Non-Ex and Ex i isolator, 1x DP/Ex i output, manual adjustment of the DP transfer rate up to 1.5 Mit/s, switchable DP bus termination (Ex e side). PINs (Ex e): IN/OUT: = RxD/TxD-P, = RxD/TxD-N, SC = DP shielding, not grounded! PINs (Ex i): OUT: 1 = RxD/TxD-P, 1 = RxD/TxD-N, SC = DP shielding, not grounded! 6 cable, blue! (Intrinsic safety) x 10/ NDC110-EX - 2 x 0.32 mm 2 (WG22/1), 65/330/1000 m 10/ EN 7

8 - Redundancy concept with RLM01 (Redundancy Link Module) PROFIUS Installation suggestion Ethernet TCP/IP Master (Red.) Controller Variant 1: Master incl. redundant DP Interface. (Option) Linking Device DP/P: See page 10 Variant 2: Master incl. individual DP Interface L 50 m Ethernet TCP/IP (red. optional) 24 V DC 150 m M Master Controller U S U S s L T (red. optional) 24 V DC 150 m L 50 m M 1 (red. optional) 24 V DC 150 m M L 50 m U S US (red.) (red.) Remote I/O Variant 3: Redundancy Controller incl. individual DP Master Interface. Line Line Master 1 M RLM01 Master 1 M Slave 1 RLM01 Slave 3 Slave 4 M Slave 2 M Slave 5 Slave n M00525_EN 1 Description Catalog No. Data sheet RLM01 - DP Redundancy Link Module 3DZ000398R1 3DD011641R Converts a non-redundant DP line (M) to two redundant DP lines ( / ) and vice versa [redundant DP lines ( / ) to DP line (M)]. - Transfer rate 9.6 kit/s Mit/s, IP 20 Power PINs: individual: 3 = (+), 2 = (-), 1 = PE redundant: 6 = (+), 5 = (-) 8 10/ EN

9 PROFIUS Installation suggestion 10/ EN 9

10 /P - Segment Coupler (redundant) PROFIUS Installation suggestion V DC 16 (typ ) Optional Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P- = green See page S + - S + - S + - S 4 PROFIUS P Ex (Haz.) area Non-Ex area See page 13 Or C See page 14/15 M00544_EN Important! - With a redundant gateway configuration or use of the Gateway DTM.FC for diagnostic transmission, an address must be set by means of a DIP switch. - The addresses "1" & "2" must not be assigned for P field devices. - Max. 30 P field devices per power supply module (red.). - ll modules can be combined with all other modules. - Do not use NDE2x0-NO cable connectors for applications in hazardous area Zone 2/Class I, Div First check that the Gateway / diagnostic DTMs have been approved for your frame application - DTM.FC Gateway and DTM-FC.D asic will be found on: The four system combinations below are possible: - Redundant connection & redundant supply - Redundant connection & simple supply - Simple connection & redundant supply - Simple connection & simple supply Description Catalog No. Data sheet 1 NDL300 - Motherboard 3KXN635300L0120 DS/NDL for 2x DP/P gateway modules (redundant), DIN top-hat rail, IP 20, II 3G Ex n IIC T4, Zone 2/Class I, Div Includes SU-D cable, 25-pin, for connecting the motherboards - Includes DIP switch for address assignment 2 NDL300 - DP/P Gateway 3KXN635300L0150 DS/NDL DP bus up to 12 Mbit/s, transparent, for 4x power supply modules, IP 20, II 3G Ex n II T4, Zone 2/Class I, Div DTM.FC (optional) for gateway parameterization or diagnostic transmission 3 NPP310 - Motherboard 3KXN636310L0120 DS/NDL for 2x4 power supply modules (redundant) and for 1x diagnostic module, 4x switchable P bus terminators, DIN top-hat rail, IP 20, II 3G Ex nc IIC T4, Zone 2/Class I, Div. 2. Power PINs: PRI: + = (+), - = GND, SEC (optional): + = (+), - = GND P PINs: OUT segment 1: + = P+, - = P-, S (NGP310) = shield and! motherboard grounding firmly OUT segment 2/3/4: + = P+, - = P-, S (NGP310) = shield 4 NGP310 (optional) 3KXN617310L0100 DS/NDL Grounding connection set for large-surface connection of the trunk cable shields. 5 Power supply modules P bus fixed at kbit/s, IP 20, II 3G Ex n II T4, Zone 2/Class I, Div. 2. NGP310 (for "", "", or "C") 3KXN617310L0150 DS/NDL - P power feed: U S = V DC, I S 500 m, elec. isolation. NGP310 (for "", "", or "C") 3KXN617310L0152 DS/NDL - P power feed: U S = V DC, I S 360 m, elec. isolation. 6 Diagnostic modules (optional) For supply & P bus, IP 20, Zone 2/Class I, Div. 2. NGP312 (asic module), II 3G Ex nc IIC T4 3KXN617312L0160 DS/NDL - Check power sources, power supply modules, and P for overload and short circuit, etc. - Messages only transmitted by means of relay contact. NGP312 (dvanced module), II 3G Ex n IIC T4 3KXN617312L0161 DS/NDL - dditional physical layer checks. - DTM Diagnostic Manager (Gateway DTM.FC is mandatory and one of the following three) - DTM-FC.D DTM asic - NGP312 DTM Professional, 100 segments 3KXN617312L0170 DS/NDL - NGP312 DTM Professional, > 100 segments 3KXN617312L0171 DS/NDL 10 10/ EN

11 PROFIUS Installation suggestion /P Segment Coupler (simplex) V DC 16 (typ ) Optional Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P- = green See page S + - S + - S + - S 4 Ex (Haz.) area Non-Ex area PROFIUS P See page 13 C Or See page 14/15 M00545_EN Important! - With use of the Gateway DTM.FC for diagnostic transmission, an address must be set by means of a DIP switch. - The address "1" must not be assigned for P field devices - Max. 31 P field devices per power supply module. - ll modules can be combined with all other modules. - Do not use NDE2x0-NO PROFIUS DP cable connectors for applications in hazardous area Zone 2/Class I, Div First check that the Gateway / diagnostic DTMs have been approved for your frame application. - DTM.FC Gateway and DTM-FC.D asic will be found on: Description Catalog No. Data sheet 1 NDL300 - Motherboard 3KXN635300L0110 DS/NDL for 1x DP/P gateway modules, DIN top-hat rail, IP 20, II 3G Ex n IIC T4, Zone 2/Class I, Div Includes SU-D cable, 25-pin, for connecting the motherboards - Includes DIP switch for address assignment 2 NDL300 DP/P Gateway 3KXN635300L0150 DS/NDL DP bus up to 12 Mbit/s, transparent, for 4x power supply modules, IP 20, II 3G Ex n II T4, Zone 2/Class I, Div DTM.FC (optional) for gateway parameterization or diagnostic transmission 3 NPP310 - Motherboard 3KXN636310L0110 DS/NDL for 4 power supply modules and for 1x diagnostic module, 4x switchable P bus terminators, DIN top-hat rail, IP 20, II 3G Ex nc IIC T4, Zone 2/Class I, Div. 2. Power PINs: PRI: + = (+), - = GND, SEC (optional): + = (+), - = GND P PINs: OUT segment 1: + = P+, - = P-, S (NGP310) = shield and! motherboard grounding firmly OUT segment 2/3/4: + = P+, - = P-, S (NGP310) = shield 4 NGP310 (optional) 3KXN617310L0100 DS/NDL Grounding connection set for large-surface connection of the trunk cable shields. 5 Power supply modules P bus fixed at kbit/s, IP 20, II 3G Ex n II T4, Zone 2/Class I, Div. 2. NGP310 (for "", "", or "C") 3KXN617310L0150 DS/NDL - P power feed: U S = V DC, I S 500 m, elec. isolation. NGP310 (for "", "", or "C") 3KXN617310L0152 DS/NDL - P power feed: U S = V DC, I S 360 m, elec. isolation. 6 Diagnostic modules (optional) For supply & P bus, IP 20, Zone 2/Class I, Div. 2. NGP312 (asic module), II 3G Ex nc IIC T4 3KXN617312L0160 DS/NDL - Check power sources, power supply modules, and P for overload and short circuit, etc. - Messages only transmitted by means of relay contact. NGP312 (dvanced module), II 3G Ex n IIC T4 3KXN617312L0161 DS/NDL - dditional physical layer checks. - DTM Diagnostic Manager (Gateway DTM.FC is mandatory and one of the following three) - DTM-FC.D DTM asic - NGP312 DTM Professional, 100 segments 3KXN617312L0170 DS/NDL - NGP312 DTM Professional, > 100 segments 3KXN617312L0171 DS/NDL 10/ EN 11

12 /P - Segment Coupler (compact) PROFIUS Installation suggestion See page V DC Color coding : RxD/TxD-P = red RxD/TxD-N = green - + PROFIUS P: P+ = red P- = green + - S + - S PROFIUS P Ex (Haz. rea) Non-Ex area See page 13 Or See page 14/15 C M00557_EN Important! - The address "1" must not be assigned for P field devices. - Max. 31 P field devices per power supply module. - Not permitted for Ex (Haz.) areas. Description Catalog No. Data sheet 1 NDL300 (compact) 3KXN635300L0001 DS/NDL IP 20, comprises the following components: 1x Motherboard compact, DIN rail, system M36 1x /P gateway, DP bus up to 12 Mbit/s, transparent 2x Power supply modules, P bus fixed at kbit/s, P power feed: U S = V DC, I S 360 m, incl. fixed bus termination Power PINs: + = (+), - = GND P PINs: OUT segment 1: + = P+, - = P-, S = shield and! motherboard grounding firmly OUT segment 2: + = P+, - = P-, S = shield Limits and rules for page 13 up to 15! PROFIUS P segment Calculation of the cable length L T : When using differential P cable diameter the characteristics (max. length L T ) changed out of the charts page 13 up to L Total 1,900 m unchanged. - For calculation please add the respective conductor resistance (loop) of the cable types into the formula. cable types: - NPC080-xx 0.88 mm /km (loop) - NPC150-xx 1.30 mm /km (loop) - NPC250-xx 2.10 mm /km (loop) 12 10/ EN

13 PROFIUS Installation suggestion PROFIUS P Fieldbus barrier in Ex (Haz.) area Description Catalog No. Data sheet 1 P overvoltage protection, 2-channel, IN 450 m (option) NGV211-NO - Cartridge for NGV210-NO NGV210-NO - asic element for top-hat rail / / PINs: 1. channel: IN: 01 = P+, 05 = P-, 03 = shielding OUT: 02 = P+, 06 = P-, 04 = shielding 2. channel: IN: 07 = P+, 11 = P-, 09 = shielding OUT: 08 = P+, 12 = P-, 10 = shielding 2 PROFIUS P cable, black (No intrinsic safety) NPC080-NO mm 2, 43.6 Ω/km, 65/330/1000 m NPC150-NO 1) mm 2, 27.4 Ω/km, 1000 m NPC250-NO 1) mm 2, 17.2 Ω/km, 1000 m x / / / NG900 Fieldbus barrier 3KXN611900L0010 DS/NG - IP 67, aluminum housing, II 2 (1G/D) G Ex me [ia] IIC T4-6x cable bushing plastic (shielding capacitive!), switchable bus termination PINs: trunk cable (L T ): IN: 03 = P+, 04 = P-, 05 = S OUT: 08 = P+, 07 = P-, 06 = S PINs: spur cable (L S ): 4 x OUT: 10 = P+, 11 = P-, 12 = S / 13 = P+, 14 = P-, 15 = S 16 = P+, 17 = P-, 18 = S / 19 = P+, 20 = P-, 21 =S 4 6x EMC cable bushing Special order! (Shielding braid on ground via cable bushing) 5 PROFIUS P cable, blue (Intrinsic safety) NPC080-EX 0.88 mm 2, 43.6 Ω /km, 65/330/1000 m x 10/ NPE300-NE - P cable socket, IP / metal case, M12, for Ex (Haz.) and Non-Ex area PINs: 1 = P+, 3 = P-, case (or 4) = shielding 7 NGV220-EX 2) - P overvoltage protection (optional) / IP 67 metal case, for M20 x 1.5 cable gland mounting, II2(1)G Ex ia IIC T4/T5/T6 PINs: IN: (+) = P+, (-) = P-, shielding on ground via EMC cable bushing PINs: OUT: red = P+, black = P-, shielding on ground via metal case - Possible use at the Fieldbus barrier of the IN/OUT-PINs of the trunk cable (L T ) by using EMC cable bushing (shielding capacity bridged). 8 NG900 Fieldbus barrier - Supply voltage per channel: U S V (at 10 m) up to 9.78 V (at 43 m) - Supply current per channel: I S 43 m - Supply voltage per arrier: U S min V DC - asic current per arrier: I basic 49 m Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P- = green 1) y using the 1.3 / 2.1 mm 2 cable it is not possible to use plugs / sockets! 2) y using the field device types FXE4000, FV4000, FS4000 it is not possible to use NGV220! Limits and rules! When using the Segment coupler, Fieldbus barrier and cable. (by other coupler / arriers / cable the limits are calculated new) per PROFIUS P segment: - number of P subscribers 16 - number of Fieldbus barrier 4 - Σ current (I) 450 m (max. current via NGV21x-NO) Σ current (I) = Σ basic current of all s and Fieldbus barrier + error current of one device - trunk cable length (L T ) see diagram at U S min. 16.0V DC of Fieldbus barrier (length depending on Σ current and cable diameter) - spur cable length (L S ) (acc. to the FISCO/IEC model): t spur cable: L S 120 m / at spur cable: L S 90 m t spur cable: L S 60 m - cable length L total = L T + (Σ L S ) 1900 m 10/ EN 13

14 PROFIUS P Passive T and 4-way junction (IP 66) in Non-Ex area PROFIUS Installation suggestion L T See page 10/11/12 PROFIUS P OUT IN 28VDC! (Option) PROFIUS P (Option) PROFIUS P L S s Description Catalog No. Data sheet 1 P overvoltage protection, 2-channel, I N 450 m (Optional) NGV211-NO - Cartridge for NGV210-NO NGV210-NO - asic element for top-hat rail / / PINs: 1. channel : IN: 01 = P+, 05 = P-, 03 = shielding OUT: 02 = P+, 06 = P-, 04 = shielding 2. channel: IN: 07 = P+, 11 = P-, 09 = shielding OUT: 08 = P+, 12 = P-, 10 = shielding 2 PROFIUS P cable, black (No intrinsic safety) NPC080-NO mm 2, 43.6 Ω/km, 65/330/1000 m NPC150-NO 1) mm 2, 27.4 Ω/km, 1000 m x / / NPJ120-NO - P T-junction, IP / x EMC cable bushing, switchable bus termination (Shielding braid on ground via cable bushing) PINs: trunk cable (L T ): IN/OUT: = P-, = P+ 4 NPE100-NE - P cable plug, IP / metal case, M12, for Ex (Haz.) and Non-Ex area PINs: 1 = P+, 3 = P-, case (or 4) = shielding 5 PROFIUS P cable, black x 10/ NPC080-NO mm 2, 43.6 Ω/km, 65/330/1000 m NGV220-NO 2) - P overvoltage protection (Optional) / IP 67 metal case, for M20 x 1.5 cable gland mounting PINs: IN: (+) = P+, (-) = P-, shielding on ground via EMC cable bushing PINs: OUT: red = P+, black = P-, shielding on ground via metal case 7 NPJ130-NO - P T-junction, IP / x EMC cable bushing, switchable bus termination (Shielding braid on ground via cable bushing) PINs: trunk cable (L T ): IN/OUT: = P-, = P+ PINs: spur cable (L S ): OUT: = P-, = P+ 8 NPE300-NE - P cable socket, IP / metal case, M12, for Ex (Haz.) and Non-Ex area PINs: 1 = P+, 3 = P-, case (or 4) = shielding 9 NPJ420-NO - P 4-way junction, IP / x EMC cable bushing, switchable bus termination (Shielding braid on ground via cable bushing) PINs: trunk cable (L T ) IN/OUT: = P-, = P+ NPJ460-NO - P 4-way junction, IP / x EMC cable bushing, switchable bus termination (lternative, not shown) 10 NDZ413-NE - protection cap for sockets M / Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P- = green 1) y using the 1.3 mm 2 cable it is not possible to use plugs / sockets! 2) y using the field device types FXE4000, FV4000, FS4000 it is not possible to use NGV220! us termination each at the beginning and the end of every P segment necessary! M00546_EN Limits and rules! When using the Segment coupler, junction and cable. (by other coupler / junction / cable the limits are calculated new) per PROFIUS P segment: - number of P subscribers 31 (30 by using of red. Segment coupler) - Σ current (I) 450 m (max. current via NGV21x-NO) Σ current (I) = Σ basic current of all field devices + error current of one device - trunk cable length (L T ) of 0.88 mm 2 cable see diagram (length (L T ) depending on Σ current, U S field device and cable diameter) - spur cable length (L S ): at spur cable: L S 120 m / at spur cable: L S 90 m at spur cable: L S 60 m / at spur cable: L S 30 m at (30) spur cable: L S 1 m - cable length L total = L T + (Σ L S ) 1900 m L/m T t P power supply of 28VDC! & cable type = 0.88 mm 2 US = 9VDC =10VDC =11VDC =12VDC =16VDC m M00537_EN 14 10/ EN

15 PROFIUS Installation suggestion PROFIUS P Passive T junction (IP 20) in Non-Ex area 1 Description Catalog No. Data sheet P overvoltage protection, 2-channel, I N 450 m NGV211-NO - Cartridge fo NGV210-NO NGV210-NO - asic element for top-hat rail / / PINs: 1. channel: IN: 01 = P+, 05 = P-, 03 = shielding OUT: 02 = P+, 06 = P-, 04 = shielding 2. channel: IN: 07 = P+, 11 = P-, 09 = shielding OUT: 08 = P+, 12 = P-,10 = shielding 2 PROFIUS P cable, black (No intrinsic safety) NPC080-NO mm 2, 43.6 Ω/km, 65/330/1000 m NPC150-NO 1) mm 2, 27.4 Ω /km, 1000 m NPC250-NO 1) mm 2, 17.2 Ω /km, 1000 m x / / / NGJ100-NE - P junction family, IP 20 3 P shield module, for stabilizing the fieldbus shield 3KXN623100L / PINs: Trunk cable (L T ): IN: S = shield (braided shield connected to ground via the module) 4 P line-in module 3KXN623100L / For connecting the main line to the current-limiter modules, max. voltage 30 V DC, rated current 380 m PINs: Trunk cable (L T ): IN: = P+, = P- 5 P current-limiter module(s), 3KXN623100L / max. 20 modules per line-in module, supply voltage U S = 17.5 V DC, supply current I S = 62 m PINs: Spur cable (L S ): OUT: = P+, = P- 6 P bus termination module at end of every 3KXN623100L / main line for NGJ100-NE 7 NGZ100-NE - Jumper 3KXN622100L000x 10/ pol, 4 pol or 15 pol to wrap the modules easily. Terminal for segment expansion On request! NGJ100-NE - asic current per Line-In module: I basic 5.0 m - asic current per Current-Limiter module: I basic 5.0 m 8 NPE300-NE - P cable socket, IP / Metal case, M12, for Ex (Haz.) and Non-Ex area PINs: 1 = P+, 3 = P-, case (or 4) = shielding 9 NGV220-NO 2) (optional) - P overvoltage protection / IP67 metal case, for M20 x 1.5 cable gland mounting PINs: IN: (+) = P+, (-) = P-, shielding on ground via EMC cable bushing PINs: OUT: red = P+, black = P-, shielding on ground via metal case Color coding : RxD/TxD-P = red RxD/TxD-N = green PROFIUS P: P+ = red P - = green 1) y using the 1.3/2.1 mm 2 cable it is not possible to use plugs / sockets! y using the 2.1 mm 2 cable it is not possible to use NGV220-NO! 2) y using the field device types FXE4000, FV4000, FS4000 it is not possible to use NGV220! Limits and rules! When using the Segment coupler, junction and cable. (by other coupler / junction / cable the limits are calculated new) per PROFIUS P-Segment: - number of P subscribers 20 - Σ current (I) 450 m (max. current via NGV21x-NO) Σ current (I) = Σ basic current (all field devices, Line-In, Current-Limiter modules) + error current of one device - trunk cable length (L T ) of 0.88 mm 2 cable see diagram (length (L T ) depending on Σ current, U S field device and cable diameter) - spur cable length (L S ): at spur cable: L S 120 m at spur cable: L S 90 m at spur cable: L S 60 m at spur cable: L S 30 m m - cable length L total = L T + (Σ L S ) 1900 m M00537_EN L/m T t P power supply of 28 V DC! & cable type = 0.88 mm 2 US = 9VDC =10VDC =11VDC =12VDC =16VDC 10/ EN 15

16 Shielding and grounding For information of shielding and grounding refer to the PROFIUS Technical Guidelines ( PNO - Order No , PROFIUS RS 485-IS - User and Installation Guidelines, chapter 3.5 : Ideal combination (schematic diagram) utomation system / Master PROFIUS Installation suggestion T Fieldbus barrier/ Ex repeater T T T Equipotential bonding Non-Ex area Ex (Haz.) area M00548_EN : Possible alternative (schematic diagram) utomation system / Master T Fieldbus barrier / Ex repeater T T T Equipotential bonding Function grounding Non-Ex area Ex (Haz.) area M00549_EN 16 10/ EN

17 PROFIUS Installation suggestion PROFIUS P Shielding and grounding For information of shielding and grounding refer to the PROFIUS Technical Guidelines ( PNO - Order No , PROFIUS P - User and Installation Guidelines, chapter PROFIUS P: Ideal combination (schematic diagram) Power supply cable screened PROFIUS P Trunk cable PROFIUS P Spur cable e.g.: Segment coupler Linking Device Field junction Spur cable Equipotential bonding Non-Ex area Ex (Haz.) area M00550_EN PROFIUS P: Possible alternative with capacitive grounding in the Non-Ex area (schematic diagram) Power supply cable screened PROFIUS P Trunk cable PROFIUS P Spur cable Field junction e.g.: Segment coupler Linking Device Capacitor to separate: fixed dielectric ( e.g. Ceramics) C 10 nf insulation test voltage 1500 V Spur cable Equipotential bonding Function grounding Non-Ex area Ex (Haz. rea) M00551_EN 10/ EN 17

18 PROFIUS P-layout example Fieldbus barrier in Ex (Haz.) area PROFIUS Installation suggestion Calculation example for one PROFIUS P segment: Number of P subscriber and cable length Structure referring to the variant on page 13 Guideline: (e. g. Tank with a mixer) P segment with 16 field devices in the Ex (Haz.) area for an application field device types: For Flow 3x FEH300, 3x FCM2000 For Pressure 6x 2600T(266xxx) For Temperature 2x TTH300 For Positioning 2x TZIDC-110 Power supply by the module NGP310 (U S = V DC, I S 500 m) Fieldbus barrier NG900 Spur length per field device max. 10 m and L T min. 750 m Question: 1. Is the structure possible? Referring to the current and voltage supply. 2. If yes, which max. P segment cable length can be laid? Referring to P cable of 1.30 mm 2, from the Power supply module up to the last P field device Calculation: Create a table with the values U s Min., I basic current and I error current for the Fieldbus barrier and the five field device types. The values are shown in the following data sheet: 10/ Device overview for PROFIUS P P devices U s Min. I basic current I error current 4x NG V 49.0 m --- 3x FEH V 10.0 m 3.0 m 3x FCM V 14.0 m 12.0 m 6x 2600T(266xxx) 9.0 V 15.0 m 5.0 m 2x TTH V 12.0 m 8.0 m 2x TZIDC V 10.5 m 4.5 m Σ m 1. ppraise and calculate (U, I): - for the voltage supply: Highest U s Min. (16.0 V) is less than U S = V DC of the Power supply module. - for the current supply: Sum I basic current (403.0 m) plus 1x highest I error current (12.0 m) is less than I S 500 m of the Power supply module. 2. Calculation of the P segment length (L T ): - Max. L T is approx. 1,055 m. Shown in the diagram page 13 by means of the characteristic curve for the P cable 1.30 mm 2 and of the sum current (0.415 ) - Max. total length of the P segment cable is equal to L max = 1,055 m + L S (16 x 10 m) = 1,215 m is less than the max. allowed 1,900 m. Result: 1. The structure is possible in principle! 2. L max = 1,215 m. Cycle time (approximate value) on the P segment: - Depending on the Segment coupler type, number of P devices and F s / P device (Function locks). The cycle time could be affected additionally by acyclic communication, reties, diagnostic data and bus parameter. P devices Overhead / P device F min. / P device F max. / P device Cycle time min. Cycle time max. 1x Segment Coupler - / - - / - - / - 40 ms (simplex) 3x FEH it 5 yte 33 yte 34 ms 56 ms 3x FCM it 5 yte 34 yte 34 ms 57 ms 6x 2600T(266xxx) 317 it 5 yte 15 yte 69 ms 84 ms 2x TTH it 5 yte 29 yte 23 ms 35 ms 2x TZIDC it 8 yte 25 yte 24 ms 33 ms Cycle time approx.: from 224 ms up to 305 ms Speak to us for the calculation of complex PROFIUS topologies / EN

19 PROFIUS Installation suggestion PROFIUS P layout example - Passive 4-way junction in Non-Ex area Calculation example for one PROFIUS P segment: Number of P subscriber and cable length Structure referring to the variant on page 14 Guideline: (e.g. Tank with a mixer) P segment with 16 field devices in the Non-Ex area for an application field device types: For Flow 3x FEH300, 3x FCM2000 For Pressure 6x 2600T(266xxx) For Temperature 2x TTH300 For Positioning 2x TZIDC-110 Power supply by the module NGP310 (U S = V DC, I S 500 m) Passive 4-way junction NPJ460-NO Spur length per field device max. 10 m and L T min. 750 m Question: 1. Is the structure possible? Referring to the current and voltage supply. 2. If yes, which max. P segment cable length can be laid? Referring to P cable of 0.88 mm 2, from the Power supply module up to the last P field device. Calculation: Create a table with the values U s Min., I basic current and I error current for the junction and the five field device types. The values are shown in the following data sheet: 10/ Device overview for PROFIUS P P device U s Min. I basic current I error current 4x NPJ460-NO x FEH V 10.0 m 3.0 m 3x FCM V 14.0 m 12.0 m 6x 2600T(266xxx) 9.0 V 15.0 m 5.0 m 2x TTH V 12.0 m 8.0 m 2x TZIDC V 10.5 m 4.5 m Σ m 1. ppraise and calculate (U, I): - for the voltage supply: Highest U s Min. (9 V) is less than U S = V DC of the Power supply module. - for the current supply: Sum I basic current (207.0 m) plus 1x highest I error current (12.0 m) is less than I S 500 m of the Power supply module. 2. Calculation of the P segment length (L T ): - Max. L T is > m! Shown in the diagram page 14 2 by means of the characteristic curve for the P cable 0.88 mm, the sum current (0.219 ) and highest U s Min. (9.0 V). - Max. total length of the P segment cable is equal to L max = m + L S (16x 10 m) > m! ttention: Not exceed the max. allowed m! Max. L T = m - L S (16x 10 m) m! Result: 1. The structure is possible in principle! 2. L max = m. Cycle time (approximate value) on the P segment: - Depending on the Segment coupler type, number of P devices and F s / P device (Function locks). The cycle time could be affected additionally by acyclic communication, reties, diagnostic data and bus parameter. P devices Overhead / F min. / F max. / Cycle time min. Cycle time max. P device P device P device 1x Segment Coupler - / - - / - - / - 40 ms (simplex) 3x FEH it 5 yte 33 yte 34 ms 56 ms 3x FCM it 5 yte 34 yte 34 ms 57 ms 6x 2600T(266xxx) 317 it 5 yte 15 yte 69 ms 84 ms 2x TTH it 5 yte 29 yte 23 ms 35 ms 2x TZIDC it 8 yte 25 yte 24 ms 33 ms Cycle time approx.: from 224 ms up to 305 ms Speak to us for the calculation of complex PROFIUS topologies. 10/ EN 19

20 Contact us utomation GmbH Service Instrumentation Kallstadter Str Mannheim, Germany Customer Service Center: * automation.service@de.abb.com * 4 cents/minute from German landlines, max. 42 cents/minute from mobiles. Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of. Copyright 2011 ll rights reserved 10/ EN Rev. D KXN040000R1001

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically

More information

Fieldbus Components Section K

Fieldbus Components Section K ection K This section covers our full range of connection technology for Profibus DP and Profibus P available in cabinet or field mount formats and for harzardous locations. We also supply a complete range

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

VIPA Accessories. ProfiHub B BE00 Manual

VIPA Accessories. ProfiHub B BE00 Manual VIPA Accessories ProfiHub B5 973-5BE00 Manual HB151E Rev. 12/04 January 2012 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

Capacitance Level Measurement Electronic insert FEC 12

Capacitance Level Measurement Electronic insert FEC 12 Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

Siemens Industry Online Support

Siemens Industry Online Support MICROMASTER (MM4): What are the possible causes of F0070 on MICROMASTER 4, and how do I avoid them? FAQ November 2013 Siemens Industry Online Support Answers for industry. Table of contents Table of contents

More information

Operating Instructions

Operating Instructions R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D-74638 Waldenburg (Württemburg) Germany Ordering code Version: 2.1 Date of issue: 11.12.2017 Applicable to: I.S. 1 Target group: Trained qualified staff (in accordance

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

ERbic Bus Interface Connector System.  Catalog E /06 Edition 4 ERbic Bus Interface Connector System www.erni.com Catalog E 074441 01/06 Edition 4 www.erni.com 2 Catalog Katalog D E 074441 074440 01/06 Edition Ausgabe 4 3 www.erni.com Table of Contents ERNI bus interface

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

Signal conditioning instruments

Signal conditioning instruments Signal conditioning instruments Overview Page 242 VEGAMET Page 244 VEGASCAN Page 248 VEGASTAB Page 249 VEGATOR Page 250 ISO housing Page 258 Components Page 259 2 24 Signal conditioning instruments For

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and

More information

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS ISO 9001:2000 C R US MULTITURN SOLUTE ENCODER EM PROFIUS Presentation The Eltra multi-rotation Profibus encoder (Identification Number 0x0599) conforms to the standard Profibus DP described in the European

More information

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011 Technical data 2CDC512091D0201 ABB EQmatic Description of product QA/S 3.xx.1 are modular DIN Rail components (MDRC) Pro M design for installation in distribution boards on a 35 mm mounting rail. They

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

SITRANS F M. Transmitter MAG 5000/6000 4/33

SITRANS F M. Transmitter MAG 5000/6000 4/33 Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02 Owner s Manual multiswitch 1.41 Firmware-Version 1.06 OS- Version 1.02 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of: Juli 19 th

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

Field IT. PROFIBUS DP/PA Linking Device LD 800P. User Instructions

Field IT. PROFIBUS DP/PA Linking Device LD 800P. User Instructions Field IT PROFIBUS DP/PA Linking Device LD 800P User Instructions Field IT PROFIBUS DP/PA Linking Device LD 800P User Instructions NOTICE The information in this document is subject to change without notice

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Siemens Industry Online Support

Siemens Industry Online Support SINAMICS G120 (CU240x DP): What are the possible causes of F0070 at G120, and how do I avoid them? CU240S DP, CU240D DP FAQ November/2013 Siemens Industry Online Support Answers for industry. Table of

More information

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Technical Information RIA45 Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values Application Plant and apparatus engineering and construction Control

More information

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3 Preface SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Properties 1 Parameters 2 Error and system messages 3 Response times 4 Manual

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS UNI EN ISO 9001 C R US MULTITURN SOLUTE ENCODER PROFIUS Presentation The ELTR Profibus multi-turn encoder (Identification Number 0x0599) conforms to the Profibus DP standard, described by European Standard

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Pressure transmitter For applications in hazardous areas Model IS-3

Pressure transmitter For applications in hazardous areas Model IS-3 Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine

More information

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine. Thermoacoustics Technical Brochure Product Line for Combustion Dynamics on Gas Turbine Modular Measuring Chains. This technical brochure provides an overview how the various system components of the Kistler

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

HARTING Ethernet cabling cables and connectors, 4 wire

HARTING Ethernet cabling cables and connectors, 4 wire Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation

More information

Single mode 9/125µm, duplex

Single mode 9/125µm, duplex Fiber Converter Module RS-232 MICROSENS General For the connection of devices, control units and machine controls with standard serial interfaces MICROSENS is offering special fiber converters for the

More information

Selection matrix for electronic pressure switches

Selection matrix for electronic pressure switches Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P n n n n n Compact design: 59 mm mounting depth for single or multiturn Aids for start up and operation: diagnostic LED, preset key with optical response Parameterization: Resolution, code type, direction,

More information

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Technical Information RIA46 Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Application Process recording and supervision Process control Signal

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

Model JDF Field Indicator

Model JDF Field Indicator Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities

More information

4-in-1 Motor Controller CAN

4-in-1 Motor Controller CAN 4-in-1 Motor Controller CAN Page 1 of 6 Version 1.10 Technical Data Construction Connector Housing Dimensions Weight Ambient Temperature Protection Class Plastic housing with side flaps 2x Tyco JPT 90

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)

More information

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION The Eltra multiturn Pro bus encoder series (Identi cation Number 0x0599) is complying to the Pro bus DP standard as described on the European Standard

More information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex. Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5

More information

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards BREAK-TW-V.4/4, BREAK--V.4/4 BOX DIN RACK IP56 Optoconverters are designed to transfer videosignal and or data. I FM modulation I AGC optical loss I Universal for MM and SM fibres I Up to 3 independent

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

ACT20X Series for hazardous area applications Section A

ACT20X Series for hazardous area applications Section A ACT20X Series for hazardous area applications Section A Weidmüller has specifically designed the ACT20X line for process automation applications in Ex and non-ex zones. The 17 different variants can process

More information

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8 Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between

More information

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution

More information

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter

More information

ATEX-manual for units

ATEX-manual for units ATEX-manual for units LMK70-ATEX (Zone 0) LMK70-ATEX (Zone 0/20) ATEX-Barrier Generic installation directive according to EN60079-14 (Gas) EN60079-17 (Maintenance Gas) Since LMK70-ATEX is intrinsically

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 12 scancontrol 29x gapcontrol 29x1 Technical details and versions - z-axis measuring range up to 265mm - x-axis measuring range

More information

X4 Process Controller

X4 Process Controller available KW 22-2004 Description New Slot 12NC PR5510/04 Serial I/O RS232 und RS485/422 1/2 9405 355 10041 PR5510/06 PR5510/07 PR5510/08 PR5510/09 PR5510/12 PR5510/14 PR1721/31 PR1721/32 PR1721/34 PR1721/35

More information

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Limit Detection nivotester FTC 420/421/422 Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection

More information