SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
|
|
- Maximilian Francis
- 5 years ago
- Views:
Transcription
1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SIMCO ELECTRONICS 1701 Quincy Avenue, Suite 32 Naperville, IL Kevin Summey Phone: CALIBRATION Valid To: September 30, 2018 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Electrical DC/Low Frequency Parameter/Equipment Range CMC 2, 4, 5, 6 ( ) Comments DC Voltage 3 Generate (0 to 330) mv (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 16 V/V + 1 V 8.6 V/V + 2 V 9.4 V/V + 20 V 14 V/V V 17 V/V mv Fluke 5520A/SC600 DC Voltage 3 Measure (0 to 100) mv 100 mv to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V* 6.5 V/V V 4.7 V/V V 4.7 V/V V 7.3 V/V V 7.9 V/V V* HP 3458A opt 2 *add 12 (V in /1000) 2 parts in 10 6 to all V in > 100 DC Current 3 Generate (0 to 330) A (0.33 to 3.3) ma (3.3 to 33) ma (33 to 330) ma (0.33 to 1.1) A (1.1 to 11) A (11 to 20.5) A % A % A % A % A % + 40 A [1] 0.13 % A [1] 0.17 % A Fluke 5520A/SC600 [1] Floor specification doubled after 30 seconds A2LA Cert. No ) Revised 3/15/2018 Page 1 of 10
2 Parameter/Equipment Range CMC 2, 4, 5, 6 ( ) Comments DC Current 3 Measure (0 to 1) µa (1 to 10) µa (10 to 100) A (0.1 to 1) ma (1 to 10) ma (10 to 100) ma (0.1 to 1) A % + 48 pa 66 A/A pa 27 A/A na 26 A/A + 6 na 26 A/A + 60 na 42 A/A A % + 12 A HP 3458A, opt 2 Resistance 3 Generate (0 to 11) (11 to 33) (33 to 110) (110 to 330) (0.33 to 1.1) k (1.1 to 3.3) k (3.3 to 11) k (11 to 33) k (33 to 110) k (110 to 330) k (0.33 to 1.1) M (1.1 to 3.3) M (3.3 to 11) M (11 to 33) M (33 to 110) M (0.11 to 1.1) G 40 / + 1 m 64 / m 22 / m 29 / + 2 m 22 / + 2 m 31 / / / / / / % % % k % + 3 k 1.2 % k Fluke 5520A/SC600 Resistance 3 Measure (0 to 10) (10 to 100) (0.1 to 1) k (1 to 10) k (10 to 100) k (0.1 to 1) M (1 to 10) M (10 to 100) M (100 to 1000) M 30 / / m 12 / + 1 m 12 / + 10 m 12 / / / % k 0.58 % + 12 k HP 3458A, opt 2 A2LA Cert. No ) Revised 3/15/2018 Page 2 of 10
3 Parameter/Equipment Range CMC 2, 4, 6 ( ) Comments Capacitance Generate (0.19 to ) nf (0.4 to ) nf (1.1 to ) nf (3.3 to ) nf (11 to ) nf (110 to ) nf (0.33 to ) µf (2 to ) µf (3.3 to ) µf (11 to ) µf (33 to ) µf (110 to ) µf (0.33 to ) mf (1.1 to ) mf (3.3 to ) mf (11 to ) mf (33 to 110) mf 0.61 % pf 0.44 % pf 0.42 % pf 0.24 % pf 0.23 % pf 0.23 % nf 0.23 % nf 0.23 % nf 0.24 % nf 0.34 % + 23 nf 0.38 % + 78 nf 0.38 % nf 0.37 % µf 0.37 % µf 0.37 % µf 0.59 % + 23 µf 0.86 % + 78 µf Fluke 5520A Oscilloscopes 3 Square Wave Signal Fluke 5520A/SC Hz to 10 khz 50 Impedance 1 M Impedance 1 mv to 6.6 V pk pk 1 mv to 130 V pk - pk 0.26 % V 0.13 % V DC Signal 10 Hz to 10 khz 50 Impedance 1 M Impedance 1 mv to 6.6 V 1 mv to 130 V 0.25 % + 40 V % + 40 V Level Sine Amp khz Ref. 10 mv to 5 V (p-p) 2 % V Level Sine Flatness 50 5 mv to 5.5 V Relative to 50 khz Ref. 50 khz to 100 MHz (100 to 300) MHz (300 to 600) MHz 1.8 % V 1.8 % V 3.2 % V Time Marker 50 2 ns to 20 ms (50 to 5) s 2.5 parts in 10 6 s ( *t) s/s t = time in seconds Rise Time (1 to 10) MHz > 350 ps 160 ps A2LA Cert. No ) Revised 3/15/2018 Page 3 of 10
4 Parameter/Equipment Range CMC 2 ( ) Comments Electrical Simulation of Thermocouple Indicators and Indicating Systems 3 Type E -250 C to -100 C -100 C to -25 C -25 C to 350 C 350 C to 650 C 650 C to 1000 C 0.5 C 0.16 C 0.14 C 0.16 C 0.21 C Fluke 5520A Type J -210 C to -100 C -100 C to -30 C -30 C to 150 C 150 C to 760 C 760 C to 1200 C 0.27 C 0.16 C 0.14 C 0.17 C 0.23 C Type K -200 C to -100 C -100 C to -25 C -25 C to 120 C 120 C to 1000 C 1000 C to 1372 C 0.33 C 0.18 C 0.16 C 0.26 C 0.4 C Type T -250 C to -150 C -150 C to 0 C 0 C to 120 C 120 C to 400 C 0.63 C 0.24 C 0.16 C 0.14 C A2LA Cert. No ) Revised 3/15/2018 Page 4 of 10
5 Parameter/Range Frequency CMC 2, 4, 6 ( ) Comments AC Voltage 3 Generate (1 to 33) mv (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (100 to 500) khz % + 6 V % + 6 V 0.05 % + 6 V 0.1 % + 6 V 0.28 % + 12 V 0.66 % + 50 V Fluke 5520A/SC600 (33 to 330) mv (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (100 to 500) khz % + 8 V % + 8 V % + 8 V % + 8 V % + 32 V 0.16 % + 70 V (0.33 to 3.3) V (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (100 to 500) khz % + 8 V % + 8 V % + 8 V % + 8 V % + 32 V 0.19 % + 70 V (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz % mv % mv % mv 0.03 % mv % mv (33 to 330) V 45 Hz to 1 khz (1 to 10) khz (10 to 20) khz 0.02 % + 2 mv % + 6 mv % + 6 mv % + 6 mv 0.16 % + 50 mv (330 to 1020) V 45 Hz to 1 khz (1 to 5) khz (5 to 10) khz % + 10 mv 0.02 % + 10 mv % + 10 mv A2LA Cert. No ) Revised 3/15/2018 Page 5 of 10
6 Parameter/Range Frequency CMC 2, 5, 6 ( ) Comments AC Voltage Measure 3 (1 to 10) mv (1 to 40) Hz (1 to 20) khz (100 to 300) khz 0.06 % + 3 V 0.05 % V 0.06 % V 0.14 % V 0.58 % V 4.6 % + 2 V HP 3458A, opt 2 (10 to 100) mv (1 to 40) Hz (1 to 20) khz (100 to 300) khz (0.3 to 1) MHz (1 to 2) MHz 90 V/V + 4 V 90 V/V + 2 V % + 2 V % + 2 V % + 2 V 0.35 % + 10 V 1.2 % + 10 V 1.6 % + 10 V (0.1 to 1) V (1 to 40) Hz (1 to 20) khz (100 to 300) khz (0.3 to 1) MHz (1 to 2) MHz % + 40 V % + 20 V % + 20 V % + 20 V % + 20 V 0.35 % V 1.2 % V 1.6 % V (1 to 10) V (1 to 40) Hz (1 to 20) khz (100 to 300) khz (0.3 to 1) MHz (1 to 2) MHz 90 V/V mv 90 V/V mv % mv % mv % mv 0.35 % + 1 mv 1.2 % + 1 mv 1.6 % + 1 mv (10 to 100) V (1 to 40) Hz (1 to 20) khz 0.03 % + 4 mv 0.03 % + 2 mv % + 2 mv % + 2 mv 0.14 % + 2 mv A2LA Cert. No ) Revised 3/15/2018 Page 6 of 10
7 Parameter/Range Frequency CMC 2, 4, 5, 6 ( ) Comments AC Voltage Measure 3 (cont) (100 to 700) V (1 to 40) Hz 0.05 % + 40 mv 0.05 % + 20 mv HP 3458A, opt 2 AC Current Generate 3 (30 to 330) A (0.33 to 3.3) ma (3.3 to 33) ma (33 to 330) ma (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A 1 khz % A % A % + 2 A % + 20 A 0.04 % ma % ma % + 2 ma 0.12 % + 5 ma Fluke 5520A/SC600; LCOMP off AC Current Measure 3 (5 to 100) A (0.1 to 1) ma (1 to 10) ma (10 to 100) ma (0.1 to 1) A 1 khz % A % A % + 2 A % + 20 A 0.12 % ma HP 3458A opt2 II. Electrical RF/Microwave Parameter/Range Frequency CMC 2, 6 ( ) Comments Amplitude Modulation Measure Rate: 50 Hz to 10 khz Depth: (5 to 99) % Rate: 20 Hz to 10 khz Depth: Up to 99 % 150 khz to 10 MHz 150 khz to 10 MHz 2.5 % + 1 digit 3.6 % + 1 digit HP 8902A measuring receiver w/ 11722/92A sensor & mixer A2LA Cert. No ) Revised 3/15/2018 Page 7 of 10
8 Parameter/Range Frequency CMC 2, 6 ( ) Comments Amplitude Modulation Measure (cont) Rate: 50 Hz to 50 khz Depth: (5 to 99) % Rate: 20 Hz to 100 khz Depth: Up to 99 % > 10 MHz to 1.3 GHz > 10 MHz to 1.3 GHz 1.5 % + 1 digit 3.6 % + 1 digit HP 8902A measuring receiver w/ 11722/92A sensor & mixer Rate: 50 Hz to 50 khz Depth: (5 to 99) % > (1.3 to 26.5) GHz 1.7 % + 1 digit Rate: 20 Hz to 100 khz Depth: Up to 99 % >(1.3 to 26.5) GHz 3.5 % + 1 digit Frequency Modulation Measure Rate: 20 Hz to 10 khz Dev: 40 khz Rate: 50 Hz to 100 khz Dev: 400 khz 250 khz, 10 MHz 10 MHz to 26.5 GHz 2.4 % + 1 digit 1.2 % + 1 digit HP 8902A measuring receiver w/ 11722/92A sensor & mixer Rate: 20 Hz to 200 khz Dev: 400 khz 10 MHz to 26.5 GHz 2.4 % + 1 digit Phase Modulation Measure Rate: 200 Hz to 10 khz Rate: 20 Hz to 200 khz 150 khz to 10 MHz 10 MHz to 26.5 GHz 4.0 % rad 5.0 % rad HP 8902A measuring receiver w/ HP 11792A sensor Distortion Measure (0 to -80) db (0.02 to 20) khz (20 to 100) khz 1.2 db 2.4 db HP 8903B A2LA Cert. No ) Revised 3/15/2018 Page 8 of 10
9 Parameter/Range Frequency CMC 2 ( ) Comments Tuned RF Power Measure (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm 100 khz to 1.3 GHz 0.12 db 0.14 db 0.15 db 0.16 db 0.18 db 0.21 db 0.23 db 0.25 db 0.27 db 0.29 db HP 8902A measuring receiver w/ 11722A sensor (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm > (1.3 to 18) GHz 0.12 db 0.13 db 0.15 db 0.16 db 0.19 db 0.21 db 0.23 db 0.25 db 0.27 db 0.29 db (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm > (18 to 26.5) GHz 0.13 db 0.15 db 0.16 db 0.18 db 0.21 db 0.23 db 0.25 db 0.27 db 0.29 db A2LA Cert. No ) Revised 3/15/2018 Page 9 of 10
10 III. Time & Frequency Parameter/Equipment Range CMC 2 ( ) Comments Frequency 10 MHz 10 phz/hz Fluke 910 GPS receiver Measuring Equipment 3 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. 4 Based on using the standard at the temperature the Fluke 5520A with SC600 was calibrated (tcal ± 5 C) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 o C of use. 5 Based on using the standard at the temperature the HP 3458A was calibrated (tcal ± 5 C) and an autocalibration (ACAL) was performed within the previous 24 hours (± 1 C of ambient). 6 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted. A2LA Cert. No ) Revised 3/15/2018 Page 10 of 10
11 Accredited Laboratory A2LA has accredited SIMCO ELECTRONICS Naperville, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSLI Z and any additional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC- IAF Communiqué dated 8 January 2009). Presented this 22 nd day of July President & CEO For the Accreditation Council Certificate Number Valid to September 30, 2018 Revised March 15, 2018 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NATIONAL INSTRUMENTS CALIBRATION SERVICES PENANG (NICSP) NI Malaysia Sdn Bhd 8 Lebuh Batu Maung 1 Bayan Lepas 11960 Penang Malaysia
More informationSCOPE OF ACCREDITATION TO ISO/IEC & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 800 Pleasant Valley Drive Springboro, OH 45066 Doug Schonberg Phone: 937 746 7500 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO/IEC & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 800 Pleasant Valley Drive Springboro, OH 45066 Jim Morrissey Phone: 937 746 7500 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO 17025:2005 & ANSI/NCSL Z540-1-1994 ANRITSU COMPANY CANADIAN CALIBRATION SERVICE CENTER 700 Silver Seven Road, Suite 120 Kanata, Ontario K2V1C3 CANADA Yeou-Song (Brian) Lee
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CENTRO DE METROLOGIA, CALIBRACION Y CAPACITACION INTEGRAL S.A. DE C.V. C. Cuicuicatzin #1280 Col. Aguilas de Zaragoza Cd. Juarez Chihuahua 32599 MEXICO Mario
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 PCB PIEZOTRONICS INC. 3425 Walden Avenue Depew, NY 14043 David J. Dulanski Phone: 716 684 0002 ext 2617 CALIBRATION
More informationAccredited Laboratory
American Association for Laboratory Accreditation Accredited Laboratory A2LA has accredited PCB PIEZOTRONICS INC. Depew, NY for technical competence in the field of Calibration This laboratory is accredited
More informationDRAFT SCOPE OF ACCREDITATION
DRAFT SCOPE OF ACCREDITATION 1. Electrical-DC/Low Frequency DC Voltage Source (1 to 10) V (10 to 100) V 100 V to 1 kv MEASUREMEN T 1.2 V/V 2 V/V 2 V/V Fluke 732A and 752 A (10 to 100) V 100 V to 1 kv (0
More informationNational Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Global Calibration Laboratory 6045 Cochran Road Cleveland, OH 44139 Mr. Richard Abbott Phone: 440-542-3644 Fax: 440-542-3682 E-mail: richard.abbott@flukebiomedical.com
More informationAccreditation No: LAB 018. Precision Measuring Equipment Laboratory APF, PAC Kamra, Attock, Pakistan.
Accreditation No: Awarded to Precision Measuring Equipment Laboratory APF, PA Kamra, Attock, Pakistan. The scope of accreditation is in accordance with the standard specifications outlined in the following
More informationAccreditation No: LAB 018. Precision Measuring Equipment Laboratory APF, PAC Kamra, Attock, Pakistan.
Accreditation No: Awarded to Precision Measuring Equipment Laboratory APF, PA Kamra, Attock, Pakistan. The scope of accreditation is in accordance with the standard specifications outlined in the following
More informationR&S RT-Zxx High-Bandwidth Probes Specifications
R&S RT-Zxx High-Bandwidth Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZZ80 transmission line probe... 5 R&S RT-ZS10/-ZS10E/-ZS20/-ZS30
More informatione2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration
e2b calibration certifies that the above listed instrument at the time of calibration meets or exceeds all specifications as stated in the referenced procedure (unless otherwise noted). It has been calibrated
More informationAgilent 5345A Universal Counter, 500 MHz
Agilent 5345A Universal Counter, 500 MHz Data Sheet Product Specifications Input Specifications (pulse and CW mode) 5356C Frequency Range 1.5-40 GHz Sensitivity (0-50 deg. C): 0.4-1.5 GHz -- 1.5-12.4 GHz
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) This product is no longer carried in our catalog. AFG 2020 Characteristics Features Ordering Information Characteristics
More informationCertificate of Calibration
Model Number 8720D Manufacturer Hewlett Packard Co Description Network analyzer 50MHz to 20GHz Serial Number US39150600 Options Installed 1D5 010 Date of Calibration 16 Sep 2014 Procedure STE-50114355-A.04.01
More informationR&S RT-Zxx High-Voltage and Current Probes Specifications
R&S RT-Zxx High-Voltage and Current Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZH10/-ZH11 high-voltage probes... 5 R&S RT-ZD01
More information45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2
AC Voltage Range¹ / resolution 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 khz 2.0% + 3 600.0 mv / 0.1 mv 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V 1. All AC voltage ranges are specified
More informationClamp 200 A AC/DC (+ V AC/DC + Ω)
PCE-DC1 Clamp meter 200 A AC/DC & Freq. LC display 3 2/3 digits, with backlight measures AC / DC current, AC voltage & frequency Hold function / DC A zero reset function tests voltage without contact automatic
More informationHP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications
HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications 100 Hz to 26.5 GHz The HP 71910A/P is a receiver for monitoring signals from 100 Hz to 26.5 GHz. It provides a cost effective combination
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 744 Users Supplement Issue: 6 Part Number: 691287 Issue Date: 4/06 Print Date: September 1998 Page Count: 8 Revision/Date: 1, 2/99 This supplement contains information necessary to ensure
More informationApplication Note 5098
LO Buffer Applications using Avago Technologies ABA-3X563 Silicon Amplifiers Application Note 5098 Introduction An oscillator or a voltage-controlled oscillator (VCO) is usually buffered with an external
More informationPRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment
Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 9500B Users Supplement Issue: 2 Part Number: 1625019 Issue Date: 9/06 Print Date: October 2005 Page Count: 6 Version 11 This supplement contains information necessary to ensure the accuracy
More informationAgilent 8560 E-Series Spectrum Analyzers
Agilent 8560 E-Series Spectrum Analyzers Data Sheet 8560E 30 Hz to 2.9 GHz 8561E 30 Hz to 6.5 GHz 8562E 30 Hz to 13.2 GHz 8563E 30 Hz to 26.5 GHz 8564E 30 Hz to 40 GHz 8565E 30 Hz to 50 GHz 8565E SPECTRUM
More informationPicoScope 6407 Digitizer
YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator
More informationTSG 90 PATHFINDER NTSC Signal Generator
Service Manual TSG 90 PATHFINDER NTSC Signal Generator 070-8706-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless
More informationRF Level Test System +20 dbm to 130 dbm
NRVD Power Meter optional Therm. Sensor A B Power: >-15 dbm DUT (Signal Generator, Communication Tester) 1 MHz - 3.5/6 GHz +20 dbm... -130 dbm Diode Sensor Z4 Power: -15 to -40 dbm 6 db Power =< -40 dbm
More informationSynthesized Clock Generator
Synthesized Clock Generator CG635 DC to 2.05 GHz low-jitter clock generator Clocks from DC to 2.05 GHz Random jitter
More informationImproving the accuracy of EMI emissions testing. James Young Rohde & Schwarz
Improving the accuracy of EMI emissions testing James Young Rohde & Schwarz Q&A Who uses what for EMI? Spectrum Analyzers (SA) Test Receivers (TR) CISPR, MIL-STD or Automotive? Software or front panel?
More informationFeatures. PFD Output Voltage 2000 mv, Pk - Pk. PFD Gain Gain = Vpp / 2π Rad khz 100 MHz Square Wave Ref.
HMC98LP5 / 98LP5E Typical Applications The HMC98LP5(E) is ideal for: Satellite Communication Systems Point-to-Point Radios Military Applications Sonet Clock Generation Functional Diagram Features Ultra
More informationFREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD
TECHNICAL MANUAL AF-166 INSTRUMENT CALIBRATION FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM 9390-6000-34 FREQUENCY STANDARD THIS PUBLICATION SUPERSEDES NAVAIR 17-20AF-166 DATED 1 FEBRUARY 2005 DISTRIBUTION
More informationR&S FSMR Measuring Receiver Specifications
Test & Measurement Data Sheet 09.00 R&S FSMR Measuring Receiver Specifications CONTENTS Specifications... 3 Frequency...3 Measuring receiver... 3 Frequency counter...3 RF power...4 RF level (tuned receiver)...5
More informationPicoScope 6407 Digitizer
YE AR HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis
More informationSpecifications. Reference Documentation. Performance Conditions
The material in this section is organized into two main groupings: the specification tables and the supporting figures. The specification tables include: 1. PAL general and test signal specifications 2.
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
ZVA-Zxx_dat-sw_en_5214.2033.22_umschlag.indd 1 Data Sheet 13.00 Test & Measurement R&S ZVA-Zxx Millimeter-Wave Converters Specifications 28.01.2013 15:08:06 CONTENTS General information... 3 Definitions...
More informationDisplay Information Type Backlit blue on white STN Type
Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interface USB Temperature Performance Storage : -5 C to +60 C Operation : 0 C to +50 C Relative Humidity Operation :
More informationGHz Sampling Design Challenge
GHz Sampling Design Challenge 1 National Semiconductor Ghz Ultra High Speed ADCs Target Applications Test & Measurement Communications Transceivers Ranging Applications (Lidar/Radar) Set-top box direct
More informationFull-featured CW Microwave Counters for Field, Factory or Lab
Full-featured CW Microwave Counters for Field, Factory or Lab Product Overview Agilent 53150A 20 GHz Counter Agilent 53151A 26.5 GHz Counter 46 GHz Counter High performance microwave counters: at home,
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
R&S ZVA-Zxx Millimeter-Wave Converters Specifications Data Sheet Version 19.00 CONTENTS Definitions... 3 General information... 4 Specifications... 5 Test port... 5 Source input (RF IN)... 5 Local oscillator
More informationModel 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02
Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband
More informationSMS3000X Series Spectrum Analyzer
Data Sheet SMS3000X Series Spectrum Analyzer SMS3032X SMS3021X General Description SMS3000X series spectrum analyzer has a frequency range from 9 khz up to 2.1 GHz/3.2 GHz, it is light weight and small
More informationNoise Detector ND-1 Operating Manual
Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation
More informationDatasheet SHF A
SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax ++49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 19120 A 2.85 GSa/s
More informationHewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Frequency Hewlett Packard 3577A 5Hz - 200 MHz Network Analyzer Specifications SOURCE 5 Hz - 200 MHz 0.001 Hz Amplitude
More informationCertificate of Calibration
Certificate of Calibration Manufacturer Radian Research, Inc. Instrument Model: Serial Number 123456 Firmware Revision: 07.10.14 Error Specification.01% worst case Quality Management System Customer Name:
More informationTA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual
TA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual copyright FAST ComTec GmbH Grünwalder Weg 28a, D-82041 Oberhaching Germany Version 1.6, November 2, 2016 Warranty Warranty Equipment manufactured
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More information8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Page 1 of 5 8500A The Giga-tronics 8500A Series Peak Power Meters THE ACCURACY STANDARD channel capability. For tests
More informationOver 5000 VXI cards and mainframes in stock. 1000's of pieces of Test Equipment in stock. Looking for Test Equipment? Visit us on the web at www.recycledequipment.com Recycled Equipment buys, sells, and
More informationFluke 279 FC True-rms Thermal Multimeter
TECHNICAL DATA Fluke 279 FC True-rms Thermal Multimeter 4 ways the Fluke 279 FC will make your job easier 1. Find the problem faster Scan with the thermal imager to find electrical problems rapidly and
More informationR&S RT-Zxx Standard Probes Specifications
R&S RT-Zxx Standard Probes Specifications Test & Measurement Data Sheet 16.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZP03 passive probe... 5 R&S RT-ZP05(S) passive probe... 8 R&S
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications
Analog Arts SA985 SA975 SA935 SA915 Product Specifications Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1]
More informationPM 6680B / PM 6681 / PM 6681R
PM 6680B / PM 6681 / PM 6681R Timer / Counter / Analyzers Rubidium Frequency Reference / Counter / Calibrator Technical Data PM 6681: the highest performance timer/counter/ analyzer available The PM 6681
More informationFrequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm
Frequency Range HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz Timebase Stability Standard 10 MHz timebase: f10 ppm High stability timebase (Option le5): Accuracy = Calibration &Aging rate
More informationTDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A
Technical Reference TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A Digitizing Oscilloscopes Performance Verification and Specifications 070-9384-01 Copyright
More informationAssembly Level Service Guide
Assembly Level Service Guide This guide describes how to service the Agilent 53150A, 53151A, and 53152A Microwave Frequency Counters. The information in this guide applies to instruments having the number
More informationTechnical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications
Technical Reference TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications 070-8990-04 Please check for change information at the rear of this manual. Fifth
More informationSELECTION GUIDE Series of RF and Universal Frequency Counter/Timers
SELECTION GUIDE 53200 Series of RF and Universal Frequency Counter/Timers With the Keysight Technologies, Inc. 53200 RF and Universal Frequency Counters/Timers, You Get: More bandwidth 350 MHz baseband
More informationTest Procedure for Common Path Distortion (CPD)
Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 109 2016 Test Procedure for Common Path Distortion (CPD) NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International
More informationE4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET
E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET EPM-P Power Meter Specifications Specifications describe the instrument s warranted performance and
More informationRF Semiconductor Test AXRF RF Port Upgrade Kits
RF Semiconductor Test AXRF RF Port Upgrade Kits 2017 Datasheet The most important thing we build is trust Overview AXRF RF Port Upgrade Kits are designed to improve and extend the capability of an existing
More informationRS Pro SPECTRUM ANALYZER SSA3000X SERIES
Product Datasheet ENGLISH Stock No: 1236443 (RSSA3021X) 1236444 (RSSA3032X) RS Pro SPECTRUM ANALYZER SSA3000X SERIES Features and Benefits RSSA3032X XX RSSA3021X All-Digital IFTechnology Frequency Range
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) SECTION 1 : Introduction The TSG 120 YC/NTSC Signal Generator is a simple, cost-effective test signal generator designed
More informationR&S SMB100B Signal Generator Specifications
R&S SMB100B Signal Generator Specifications Data Sheet Version 01.03 year SMB100B_dat-sw_en_3607-8182-22_v0103_cover.indd 1 07.09.2018 13:41:00 CONTENTS Definitions... 3 RF characteristics... 4 Frequency...
More informationMP7200. RF Recorder / Player.
Idea All of ADIVIC MP7 Series, with its small size and light weight design, can be easily for field testing. All MP7 Series adopt user-friendly TFT-LCD touch screen. RF recorder and player system covers
More informationTranscom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure
TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure TRANSCOM T5000 Series Bench-top Vector Network Analyzer Overview T5000 Series bench-top vector network analyzer offers the high
More informationFMMX9004 DATA SHEET. Field Replaceable SMA IQ Mixer From 15 GHz to 23 GHz With an IF Range From DC to 3.5 GHz And LO Power of +17 dbm.
FMMX94 Field Replaceable SMA IQ Mixer From 15 GHz to 23 GHz With an IF Range From DC to 3.5 GHz And LO Power of +17 dbm FMMX94 is an I/Q double balanced millimeter-wave mixer module that operates across
More informationWVR500 Waveform/Vector Monitor
Service Manual WVR500 Waveform/Vector Monitor 070-8897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are
More informationFMMX9002 DATA SHEET. Field Replaceable SMA IQ Mixer From 8.5 GHz to 13.5 GHz With an IF Range From DC to 2 GHz And LO Power of +19 dbm.
FMMX92 Field Replaceable SMA IQ Mixer From 8.5 GHz to 13.5 GHz With an IF Range From DC to 2 GHz And LO Power of +19 dbm FMMX92 is an I/Q double balanced millimeter-wave mixer module that operates across
More informationE4416A EPM-P Series Single Channel Power Meter
United States Home >... > Power Meters & Power Sensors > EPM and EPM-P Series Power Meters > E4416A EPM-P Series Single Channel Power Meter Product Status: Currently Orderable Currently Supported Key Specifications
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationR&S ZN-Z154 Calibration Unit Specifications
ZN-Z154_dat-sw_en_3607-0481-22_v0101_cover.indd 1 Data Sheet 01.01 Test & Measurement R&S ZN-Z154 Calibration Unit Specifications 25.06.2014 10:27:09 CONTENTS Definitions... 3 Measurement range... 4 Effective
More informationSYNTHESIZED COMMUNICATION CONVERTERS
Dual-Conversion 1 khz or 125 khz Step Size SYNTHESIZED COMMUNICATION CONVERTERS 9600 SERIES 9400 SERIES MITEQ offers high-performance synthesized frequency converters in panel heights of 2 RU (9400 Series)
More informationR3267/3273 Spectrum Analyzers
R3267/3273 Spectrum Analyzers For 3rd-Generation Mobile Communications Present Digital Communication standards (W-CDMA, PDC, PHS, IS-136, GSM, DECT, cdmaone ) R3267/3273 New communication technologies
More informationMT8814AP. ISO-CMOS 8 x 12 Analog Switch Array. Features. -40 to 85 C. Description. Applications
MT884 8 x 2 Analog Switch Array Features Internal control latches and address decoder Short set-up and hold times Wide operating voltage: 4.5 to 3.2 2pp analog signal capability R ON 65Ω max. @ DD =2,
More informationVector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.
Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active
More informationCalibration Certificate
Page 1 of 21 Description: Vector Network Analyzer Customer: Model: PLANAR-804/1 Customer Name Serial : 12095176 Address Manufacturer: Copper Mountain Technologies State-Zip Country Date of Receipt: 10
More informationEX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR
EX04-000D DVB-T/2xT/T2 MODULATOR Key Features Capable of transmitting one DVB-T2 or two independent DVB-T signals at the same time. In full compliance with the last version of EN300744 (DVB-T) and EN302755
More information2 MHz Lock-In Amplifier
2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display
More informationSC24 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface
More informationSC26 Magnetic Field Cancelling System
SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields
More informationR&S EDS300 DME/Pulse Analyzer Specifications
R&S EDS300 DME/Pulse Analyzer Specifications year Data Sheet Version 04.01 CONTENTS Definitions... 3 Specifications... 4 Frequency... 4 Level... 4 DME signal analysis... 4 TACAN signal analysis (R&S EDS-K1
More informationQuadruple, 2:1, Mux Amplifiers for Standard-Definition and VGA Signals
9-4457; Rev ; 2/9 Quadruple, 2:, Mux Amplifiers for General Description The MAX954/MAX9542 are quadruple-channel, 2: video mux amplifiers with input sync tip clamps. These devices select between two video
More informationR&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01
R&S ZN-Z103 Calibration Unit Specifications Data Sheet V02.01 CONTENTS Definitions... 3 Measurement range... 5 Effective system data... 5 General data... 6 Ordering information... 7 2 Rohde & Schwarz R&S
More informationMT8812 ISO-CMOS. 8 x 12 Analog Switch Array. Features. Description. Applications
MT882 8 x 2 Analog Switch Array Features Internal control latches and address decoder Short set-up and hold times Wide operating voltage: 4.5V to 4.5V 4Vpp analog signal capability R ON 65 max. @ V DD
More information40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet
40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet Applications Semiconductor device testing Optical component testing Transceiver module testing The Tektronix PPG4001 PatternPro programmable
More informationML6428. S-Video Filter and 75Ω Line Drivers with Summed Composite Output. Features. General Description. Block Diagram Σ BUFFER.
www.fairchildsemi.com ML S-Video Filter and Line Drivers with Summed Composite Output Features.MHz Y and C filters, with CV out for NTSC or PAL cable line driver for Y, C, CV, and TV modulator db stopband
More informationS op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s
ET 150 Scope Controls Learning Objectives In this lesson you will: learn the location and function of oscilloscope controls. see block diagrams of analog and digital oscilloscopes. see how different input
More information7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System
7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key
More informationTranscom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1
TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure www.transcomwireless.com 1 T5000 Series Bench-top Vector Network Analyzer Overview T5000 Series Bench-top Vector Network Analyzer
More informationR&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications
ZN-Z151_152_153_dat-sw_en_3607-0881-22_v0100_cover.indd 1 Data Sheet 01.00 Test & Measurement R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications 07.10.2014 11:35:47 CONTENTS Definitions... 3 Measurement
More informationFMMX9000 DATA SHEET. Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm.
FMMX9 Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm FMMX9 is an I/Q double balanced millimeter-wave mixer module that operates across
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationFREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17
1/3 RACK-MOUNTED BLOCK CONVERTER Unit shown with Option 17 Unit shown without Option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain
More informationResearch Results in Mixed Signal IC Design
Research Results in Mixed Signal IC Design Jiren Yuan, Professor Department of Electroscience Lund University, Lund, Sweden J. Yuan, Dept. of Electroscience, Lund University 1 Work packages in project
More informationGraphics Video Sync Adder/Extractor
19-0602; Rev 2; 1/07 EVALUATION KIT AVAILABLE Graphics Video Sync Adder/Extractor General Description The chipset provides a 3-wire (RGB) interface for 5-wire (RGBHV) video by adding and extracting the
More informationSignal Stability Analyser
Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)
More informationDA E: Series of Narrowband or Wideband Distribution Amplifiers
DA1-150-10-E: Series of Narrowband or Wideband Distribution Amplifiers Key Features Dual A and B inputs. Automatic or manual switchover, configured by the Ethernet port. 1-150 MHz wideband operation. Other
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 IC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00095-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China TEST
More information