1 Fiber :: X-XXXX User Manual Telect, Inc. All rights reserved A0
2 Table of Contents Chapter 1: Introduction Tools Required Additional Parts Assemblies...3 Chapter 2: Installation Installing Patch Plates Mounting the IP-LINX Enclosure Installing the Incoming Cable Installing the Optional Cable Clamp Kit for Standard Indoor Enclosure Installing the Incoming Cable in the Outdoor Assembly Using IP-LINX to Patch Only Splice and Patch: Installing Pigtails Splice and Patch: Mounting the Splice Cassette and Finish...9 Chapter 3: Accessories and Ordering Information List of Figures Figure 1-24-Fiber IP-LINX Enclosure...3 Figure 2 - Patch Plate Installation...4 Figure 3 - Rubber Grommet...5 Figure 4 - Rubber Grommet at Cable Entry Location...5 Figure 5 - Cable Bracket...6 Figure 6 - Cable Clamp on Enclosure...6 Figure 7 - Example of Installed Panel...7 Figure 8 - Patch-Only Fiber Routing...8 Figure 9 - Splicing Pigtails...9 Figure 10 - Splice Cassette (P/N TTN-HS12)...10 Figure 11 - Splice Cassette Installation
3 Chapter 1: Introduction This guide explains how to install the wall-mounted IP-LINX and Mini IP-LINX enclosures and how to route and secure the fiber-optic cable within the enclosures. 1.1 Tools Required You need the following tools: Marking pen Phillips screwdrivers/drill Utility knife Heat gun (optional) Flathead screwdriver (for power plates) 1.2 Additional Parts IP-LINX enclosures reccomend the following additional parts that must be ordered separately: Patch plates with adapters Splice sleeves (P/N KIT-SLEEVES) Cable clamp for standard indoor enclosure only (P/N KIT-CLMP-IPL) Fiber pigtails Labels to identify pigtails (masking tape or pre-numbered cable labels) When patching only (no splice), you do not need splice cassettes or pigtails. However, you do need adapter plates to terminate the incoming cable. Refer to Accessories and Ordering Information on page 11 to order additional parts. 1.3 Assemblies Each enclosure consists of a metal chassis with a cam or keyed locking door, cable entry slots, cord grips or grommets, splice cassettes, and spools for fiber routing. An optional installation kit (P/N KIT-IP-LINX), found on page 11, includes the following: Figure 1-24-Fiber IP-LINX Enclosure Cable ties, 4 inches (6) Cable tie mount (4) Velcro cable wraps (6) Splice sleeves (12) 3
4 Chapter 2: Installation Please read and understand all instructions before starting installation. If you have questions, contact Telect Technical Support at or call When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Telect at or call Telect is not liable for transit damaged. If the product is damaged, please report it to the carrier and contact Telect. 2.1 Installing Patch Plates 1. Make sure the latches on the patch plates are pulled out. 2. Insert the patch plate (adapter key way facing up) latches into their mounting holes on the IP-LINX enclosure bulkhead. 3. Push the patch plates until they are flush with the bulkhead. 4. Push in the latches to secure each plate. Adapter plate Latch Adapter key ways Bulkhead Figure 2 - Patch Plate Installation 4
5 2.2 Mounting the IP-LINX Enclosure 1. Place the mounting-hole template against the wall where you want to mount the enclosure. 2. Mark the location of the appropriate template holes on the wall. 3. Install suitable wall anchors (not included). 4. Secure the enclosure to the wall. Figure 3 - Rubber Grommet 2.3 Installing the Incoming Cable 1. Score the grommet with a utility knife at the desired cable entry location. Refer to Figures 3 and 4 2. Push the cable through the hole that you cut in the grommet. 3. Mark the cable according to the number of wraps you wish to store in the IP-LINX enclosure. Use the tables below to determine where to make the mark. The tables provide the length of incoming cable that can be stored given the number of spool layers in the enclosure. Figure 4 - Rubber Grommet at Cable Entry Location Table 1 - Splice & Patch Marking Location: Storage Spools (Enclosure & Cassette) Inches Cm ± ±2 Table 2 - Patch Only Storage Spools Inches Marking Location: ± ± ±2 The number of wraps the cables make within the IP-LINX enclosure is left up to installer preference. For other lengths or paths, use the spools, and maintain proper bend radius. Cm 5
6 4. Slide the grommet up the cable past the mark on the cable jacket. 5. If not already, re-install the rubber gromment int he slot on the enclosure Installing the Optional Cable Clamp Kit for Standard Indoor Enclosure 1. Using a Phillips screwdriver, remove two screws from the cable bracket at the top or bottom of the panel. 2. Place the bracket around the cable in the desired location. 3. Reinstall the two screws to hold the cable bracket firmly in place. 4. Attach the clamp bracket to the top or bottom of the enclosure, next to the cable entry slot. Figure 5 - Cable Bracket Figure 6 - Cable Clamp on Enclosure Installing the Incoming Cable in the Outdoor Assembly 1. Loosen compression nut by turning counter clockwise. 2. Insert cable end through the cord grip gland. (Accepts cable dia in.) 3. Tighten compression nut by turning clockwise. 6
7 Figure 7 - Example of Installed Panel 7
8 2.4 Using IP-LINX to Patch Only Use the instructions in this section if you are using the IP-LINX enclosure for patch only. 1. From the cable entry end, wrap the fiber strands counter-clockwise around the spools. For bottom cable entry, route the strands clockwise. 2. Attach the connectors to the column of patch plate adapters closest to the back wall of the enclosure. Attach the connectors in order, from top-to-bottom. Use Table 3, Fiber Connection Color Codes, listed below. 3. Repeat Steps 1 and 2 for the next group of 12 fiber strands, and attach the connectors to the next column of adapters (1-12, top to bottom). NOTE: Always load the patch plates from top to bottom and from the rear of the IP-LINX enclosure to the front of the enclosure. Figure 8 - Patch-Only Fiber Routing Refer to the following table for fiber connection color codes. Table 3 - Fiber Connection Color Codes For This Connection: 1 Blue 2 Orange 3 Green 4 Brown 5 Gray 6 White 7 Red 8 Black 9 Yellow 10 Purple 11 Pink 12 Aqua Use This Color: 8
9 2.5 Splice and Patch: Installing Pigtails Use the instructions in this section if you are using the IP-LINX enclosure to splice and patch. 1. Attach the pigtail connectors to the column of patch plate adapters closest to the back wall of the enclosure. Always attach pigtails from top to bottom and from the back wall of the enclosure to the front. Label the pigtails accordingly. 2. Route the pigtails around the spools to take up the amount of desired slack. 3. Repeat Steps 1 and 2 for each group of 12 pigtails, then go to the next section. NOTE: The number of wraps that pigtails and incoming cable fibers make within the IP-LINX enclosure and the splice tray is left up to installer preference. 2.6 Splice and Patch: Mounting the Splice Cassette and Finish Skip this section if you are patching only. Figure 9 - Splicing Pigtails 1. (Optional) Apply heat-shrink tubing around the jacket cut point. Keep half of the heat-shrink tube length over the cable jacket, and the other half over the exposed buffer tubes or fiber strands. See Figure 7 for an example of the installed cable and panel. If incoming cable is jacketed unsheathe the fiberoptic cable by cutting the outside jacket to an appropriate length for each fiber to be spliced according to splicing machine recommendations. 2. Trim away the excess fiber length, but leave enough fiber for splice preparation. Remove the fiber from the splice cassette to the splice station. NOTE: Use this trimmed fiber to measure and trim the length of the bundle s remaining five fibers. 3. Remove the desired splice tray. 9
10 4. Splice the pigtail fiber strand to the appropriate 900-μm colored fiber strand from the incoming cable. 5. Repeat Step 4 to splice the remaining pigtail fibers to the incoming cable s color-coded fiber strands. Splice the pigtails in order. Refer to Table 3, Fiber Connection Color Codes, on page 8 to follow the color-codes. 6. Once the splicing is complete, carefully route the pigtails around the provided storage spools and inside of the splice cassette once or twice counterclockwise. For bottom cable entry, wrap the fiber strands clockwise. 7. Place the completed splice into the splice holder. 8. Carefully tuck in any stray fiber strands so that they will not be pinched. Replace the cover plate on the splice cassette. 9. Slide the splice cassette onto the threaded post. 10. Secure the cassette with the wing nuts. 11. Use the adhesive designation label to identify each connection. 12. Apply the designation label to the inside of the enclosure door. 13. Close and lock the enclosure. 14. Apply grounding cables/straps to enclosure where necessary. Figure 10 - Splice Cassette (P/N TTN-11S12) Figure 11 - Splice Cassette Installation 10
11 Chapter 3: Accessories and Ordering Information Contact your Telect Customer Service Representative at to order connectorized cables or any of the parts listed below. Table 4 - Accessories 6-Port Patch Panels SC/UPC SC/APC Port Patch Panels SC/UPC SC/APC Port Patch Panels LC/UPC LC/APC SC/UPC duplex SC/APC duplex Port Patch Panels LC/UPC LC/APC Other Patch Panels LC/APC 6-fiber, 6 DC terminals P6G LC/UPC 8-fiber, 6 DC terminals P8L 12 DC terminals PWR12 Blank patch panel Other Splice cassette TTN-HS12 Splice sleeves (qty 12) KIT-SLEEVES Fiber spool, 2-pack 055-SPOOL Cable clamp (bracket, hardware) KIT-CLMP-IPL Accessory kit: KIT-IP-LINX Velcro cable wraps, cable ties/mounts 12-pack splice sleeves Weatherproof Compression Gland, 2-pack 055-CRDGRP Ordering Information Table 5 - IP-LINX Part Number Decoder Fiber only 9 Fiber/DC E Fiber/Ethernet D DC only 0 Indoor Standard Enclosure 1 Outdoor Standard Enclosure 2 Outdoor Mini Enclosure 3 Indoor Mini Enclosure Standard 03 3 Fbr / 3 pair PWR 06 6 Fbr / 3 pair PWR 08 8 Fbr / 3 pair PWR 84 8 Fbr / 4 pair PWR Fbr / 6 pair PWR Fbr / 6 pair PWR Fbr / 6 pair PWR 00 No Pigtails 02 Stranded Pigtails 11 Ribbon Pigtails G LC/APC L LC/UPC N SC/APC S SC/UPC K Keyed (Blank is telecom hex) Mini 03 3 Fbr / 3 pair PWR 06 6 Fbr / 3 pair PWR 08 8 Fbr / 3 pair PWR 84 8 Fbr / 4 pair PWR Fbr or 6 pair PWR 11
IP-LINX. Installation Guide
Installation Guide Installation Guide, 146653-4 Copyright 2017, Telect, Inc. All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 22425 East Appleway Ave. # 11
More information24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual
24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual, Part Number
More informationCONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL
CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2
More informationOptical Distribution Box 300 Installation Guide. Version : R0.0
Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be
More information3M Distribution Box (DDB)
3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure
More informationHCS - HES Cabling Systems
HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the
More informationNC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM
NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC
More informationFIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays
FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and
More informationPanduit Recommended Best Case Practice Split Fibre
Panduit Recommended Best Case Practice Split Fibre Panduit Corp. 2009 BEST PRACTICES PN526 Table of Contents 1.0 Enclosure Prep... 2 2.0 Fibre Cable Prep and Installation... 2 3.0 Pigtail Installation...
More informationMedium Box for Cable Termination
FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling
More informationLTX Optical Distribution Panels. Ordering Guide
Contents LTX Optical Distribution Panels... 1... 1 Section One: LTX Overview... 3 1RU and 2RU Panels... 3 4RU Panels... 3 Patch Panels... 3 Combination Panels Patch and Splice... 4 Section Two: Unloaded
More informationFOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N
FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General
More informationINSTALLATION INSTRUCTIONS
LIGHTGUARD 350-20-WTC SEALED FIBER OPTIC CLOSURE VIEW ONLINE TABLE OF CONTENTS: GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...3 PACKAGE CONTENTS: ACCESSORIES...3 RECOMMENDED TOOLS...3 ADD-ON COMPONENTS...4
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE FIBER OPTIC SWING-OUT PATCH PANEL INSTRUCTION
More informationSLiC Fiber Aerial Closure System
3 SLiC Fiber Aerial Closure System SLFC 533-SP SLFC 533-TS SLFC 733-SP Instructions May 2005 78-8135-4502-3-B N C H E S R A N G E M IL L IM E T E R S.4 10.6.8 A B C 15 20 I 1.0 Kit Contents Note: Examine
More informationSection Communications Optical Fiber Backbone Cabling
Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related
More informationWCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)
Corning Cable Systems SRP-003-448 Issue 3, October 2000 Page 1 of 6 WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12) Figure 1 Table of Contents 1. General... 1 2. Description... 1 3. Tools and Materials...
More informationGel-sealed in-line fiber optic closure
SCIL-C Gel donut INSTALLATION INSTRUCTION TC-1363-1-IP Rev A, Oct 2017 www.commscope.com Gel-sealed in-line fiber optic closure Contents 1 General 2 Sizing and product kit information 3 Installation conditions
More information3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket
3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket For use with 3M SLiC Free-Breathing Fiber Optic Closures and Terminals Instructions November
More informationFOSC 450 C6 and D6 Closures
FOSC 450 C6 and D6 Closures I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure 1. General Product Information The FOSC 450 C6 and D6 fiber optic splice closures use compressed gel
More information3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR
3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3 1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The
More informationGF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual
Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber
More informationNext Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)
Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual) Fiber Combination Block Content Page INTRODUCTION............................................................................. 2 Revision
More informationClearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:
Clearview Classic Cassettes Installation Manual Clearview Classic (HD) High Density Part #: 016781 Rev: A Updated: 11.2014 7050 Winnetka Ave N Minneapolis, MN 55428 Direct: 763.476.6866 National: 800.422.2537
More informationCOYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)
OCTOBER 2004 COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x 55.88 cm 21.59 cm x 55.88 cm) Be sure to read and completely understand this procedure before applying
More information3M Fiber Optic Splice Closure 2178-L/S Series with Gasket
3M Fiber Optic Splice Closure 2178-L/S Series with Gasket Instructions for: 3M Fiber Optic Splice Closures 2178-L/S Series 3M Flame Retardant Fiber Optic Splice Closures 2178-L/S/FR 3M Cable Addition Kit
More information3M Fiber Optic Wall Mount Enclosure 8430 Series
3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6
More informationOFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation
OFDC-B8-72 I N S T A L L A T I O N I N S T R U C T I O N Outdoor fiber distribution closure Content 1 Introduction 2 Kit content 3 Closure preparation 4 Cable preparation 4.1 Feeder cable 4.2 Drop cable
More information27mm ECAM Double Cable Entry Port
27mm ECAM Double Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 27mm ECAM Double Cable (External Cable Assembly Module) Entry Port is designed to accept fiber optic loose tube & central
More information2178-L/S Series Fiber Optic Splice Case with Gasket
2178-L/S Series Fiber Optic Splice Case with Gasket Instructions for: 2178-S Splice Case 2178-LS Splice Case 2178-LL Splice Case 2181-LS Cable Addition Kit May 1997 34-7041-9949-5-A 1 Table of Contents
More informationLGX Compatible (LSX) Connector Module) User Manual)
LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1
More information2179-CD Series Fiber Optic Splice Closure. Installation Instructions
2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal
More information18mm ECAM Cable Entry Port
18mm ECAM Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 18mm ECAM (External Cable Assembly Module) Cable Entry Port Kit is designed to accept fiber optic cables with external diameters
More informationHD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity
HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex
More information3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR
3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions September 2017 78-8130-5055-2-M 2 September 2017 78-8130-5055-2-M 1.0 Kit Contents 2.0 General...
More information3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR
3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions July 2010 3 1.0 Contents 1.0 General...3 2.0 Kit Contents...3 3.0 Cable Preparation...4 4.0
More information2178 Fiber Optic Splice Case and 2181 Cable Addition Kit
2178 Fiber Optic Splice Case and 2181 Cable Addition Kit Instructions January 1994 Issue 1, 34-7029-6387-6 1 2 Contents: 1.0 General... 4 2.0 Specifications... 4 3.0 Kit Contents... 5 SECTION 1: 2178 Splice
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MO036A N-HNS (Building Node Cabinet) N-HNS (BUILDING NODE CABINET) Contents Product description Technical data ODF Splice module Cabling organisation Cable/tube/fibre handling
More informationGENUINE PARTS CAUTION
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: SATELLITE RADIO SYSTEM 2. PART NUMBERS: XM tuner kit 999U9-NV003 XM antenna kit 999U9-VR000 Sirius tuner kit 999U9-NV004 Sirius antenna
More informationFOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15
FOSC 400 Ordering Guide For Closures and Accessories Section I 3 How to Order FOSC 400 Closures Section II 5 How to Order Accessories for FOSC 400 Closures Section III 9 Other FOSC Fiber Optic Splice Closures
More informationFiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]
Fiber Optic Splice Closure GPJ09-8205 Instruction Manual [Escribir texto] 0 Table of Contents 1. General Introduction 2 2. Specification 2 3. Structure 2 4. Installation instructions. 4 5. Operation procedure.
More information3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes
FIST-GCOG2-Dx24 I N S T A L L A T I O N I N S T R U C T I O N FTTH closure for micro-tubes and micro-cables Content 1 Introduction 2 Kit content 3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx24
More informationConnectivity accessories by Nestor Cables
Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com
More informationOmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet
OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet ADCP-90-457 Issue 1 9/2010 Content Page INTRODUCTION.............................................................................
More informationPRODUCT DESCRIPTION N3S
PRODUCT DESCRIPTION N3S Nexans N3S ODF system NEXANS N3S ODF SYSTEM Contents Contents Systems description Patching frame Splice frame Patching module (KB 104/109) Splicing module Accessories Page 2 Page
More information2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table
FIST-GCO2-F INSTALLATION INSTRUCTION GCO2-FC GCO2-FD Content 1 Introduction 2 General 2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table 3 Installation
More informationINSTALLATION INSTRUCTIONS MO023A
INSTALLATION INSTRUCTIONS MO023A Nexans N3S ODF system NEXANS N3S ODF SYSTEM Content Product description Patching frame Splice frame Doors Splice module Patch module Protective cover and label panel Guides
More informationGigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT
COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationADF Module. Installation Guide. 1.1 Overview
ADF Module Installation Guide 1.1 Overview The installation sheet is divided into three sections. Section 1.2 Description on page 2 describes the areas on the frame and modules dedicated to the mounting
More informationCoyote popup display set up instructions
Coyote popup display set up instructions Frame 1 2 3 Prepare frame for assembly by locating the purple hooks on top of the frame. Stretch frame to size, snapping magnetic locking arms together. Attach
More informationMT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products
MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original
More informationSeal Kits for BUDI Enclosures
Description BUDI is a product range of compact, wall mountable fiber enclosures for indoor and outdoor use. They are specifically designed for fast deployment and easy customer connection. The FIST management
More informationFIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.
FIST-GCOG2 I N S T A L L A T I O N I N S T R U C T I O N TC-986-IP Rev A, Mar 2017 www.commscope.com FIST-GCOG2-Dx6 Content 1 Introduction 2 General 2.1 Abbreviations 2.2 Kit contents 2.3 Tools 2.4 Accessories
More informationLANmark-OF ENSPACE Patch Panel
LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE September 2016 v0.11 LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE Part Number Description Product References NSPACE.PP1U NSPACE.PP2U
More informationWater blocking tape. Locator ridge HPA-0486
Table of Contents STANDARD RECOMMENDED PROCEDURE 004-138 ISSUE 1 MARCH 2012 PAGE 1 OF 12 Sheath Removal and Mid-Span Access of Dielectric ALTOS Cable with FastAccess Technology p/n 004-138, Issue 1 1.
More informationPreferred ordering guide for NETCONNECT
Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A
More informationFiber Cable Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr Fiber CFDP2 Pedlockr OSP Pedestal)
Equipment Issue 1 First Printing, May 2011 Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr CFDP2 Pedlockr OSP Pedestal) 1. GENERAL 1.1 Document Purpose. This document provides
More informationInstruction manual. Midi Fiber Dome. Instruction manual
Midi Fiber Dome Instruction manual Product contents: - 1x Midi Fiber Dome - 1x Window Cut port seal - 1x sealing rubber (long) - 4x sealing rubber (short) - 4x stainless steel screw 4 x 25 T20-6x dummies
More information3. Electronics and MMU2 unit assembly
Written By: Jakub Dolezal 2018 manual.prusa3d.com/ Page 1 of 34 Step 1 Tools necessary for this chapter Please prepare tools for this chapter: 2.5mm Allen key for M3 screws 2mm Allen key for nut alignment
More informationCabling and Completing Assembly of the Cisco TelePresence System 1000
CHAPTER 5 Cabling and Completing Assembly of the Cisco TelePresence System 1000 Revised: April 5, 2010, Introduction This chapter describes how to set up and connect the cables, microphone and Cisco Unified
More informationCable Installation Tips
Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)
More informationCable Installation Tips
Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)
More informationFOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block
FOSC-450D I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories 2.4 Capacity 3 Preparation of the closure 4
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PARTS REQUIRED Parts in the box Single monitor Dual monitor M2 M8 M/Flex + (package contents will depend on configuration ordered) Tools required for installation 6.0 mm Hex Key
More information3M Coupling Tray FDTC-10S-COUPLINGTRAY
3M Coupling Tray FDTC-10S-COUPLINGTRAY for use with 3M Fiber Dome Closures FDC 10S Instructions July 2010 3 1.0 Introduction The 3M Coupling Tray FDTC-10S-COUPLINGTRAY can accommodate up to 10 loose tubes.
More informationNewScope-7A Operating Manual
2016 SIMMCONN Labs, LLC All rights reserved NewScope-7A Operating Manual Preliminary May 13, 2017 NewScope-7A Operating Manual 1 Introduction... 3 1.1 Kit compatibility... 3 2 Initial Inspection... 3 3
More informationWhat is SnoCam? SnoCam Installation Guide. SolarVu
4 1 2 3 4 5 6 7 8 D+ Rx- GND V+ GND V+ Power 1 2 3 4 5 6 7 8 9 10 What is? SolarVu Installation Guide SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over
More informationINSTALLATION GUIDE. LANmark-OF Zone Distribution Box
LANmark-OF Zone Distribution Box INSTALLATION GUIDE LANmark-OF Zone Distribution Box Document information Release November 2004 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg
More informationFIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N
FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N 24 Address Point Fibre distribution point (FDP) Installation guide for fibre DP Contents 1 Kit Contents 2 Accessories 3 MOBRA installation
More informationOpterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction
Introduction The Fiber Optic 19 Sliding Patch Panel has been designed to facilitate internal fiber management and also to maximize fiber density in 1U, 2U heights. The sliding tray provides easy access
More informationThe FiberMark1 offers an ideal solution for
Large Capacity Fiber Optic Splice Enclosure The Ideal Solution For Large Capacity Voice, Data, and Video Splicing Requirements. The FiberMark1 offers an ideal solution for larger fiber capacity voice,
More informationGENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~) Xterra (2006~) 3. PART NUMBERS: XM Tuner Kit 999U9-AS003 SIRIUS Tuner Kit
More informationNGF optical distribution frame
NGF optical distribution frame Contents Introduction 3 Product overview 3 Things to consider when ordering 4 Frame capacity requirements (important facts on trough space) 4 Frame lineup capacity comparisons
More informationCable ISOBUS Active Termination
ISOBUS Retrofit Kit Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity ISOBUS Retrofit Kit 4100843 1 Hex Head Bolt
More informationFACT Cable Termination Unit
FACT Cable Termination Unit INSTALLATION INSTRUCTION FACT-GSS NOTE: - the FACT-GSS multi-purpose splice shelves features Single Circuit and Single Element fiber management system technology - these shelves
More informationCable and Power Management Open-Frame Rack Cable Managers
Spec-001 Cable and Power Management Open-Frame Rack Cable Managers CABLETEK Horizontal Cable Manager DCHD shown DCHS4 shown Arrowhead fingers funnel cable into base and hold it securely Vertical and horizontal
More information6000 Series Patch Panel Terminating Instructions
6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four
More informationBulkhead Style Optical Panels. Telect LCX Series Installation Guide
Bulkhead Style Optical Panels Telect LCX Series Installation Guide Contents CHAPTER 1: LCX FIBER PANELS 5 1.1 General Information 5 1.1.1 LCX Fiber Splice Panels 5 1.1.1.1 LCX 1RU Fiber Splice Tray 24-Splice
More informationFurcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD
Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD P/N 004-277-AEN Issue 1 related literature Search www.corning.com/opcomm. Click on Resources. 1. Initial
More information3 SLiC Aerial Closure with Rubber End Seal
3 Aerial Closure with Rubber End Seal Instructions 1.0 General 1.1 This instruction bulletin describes the assembly of the 3M Aerial Closure with external bonding hanger brackets. These closures are suitable
More informationInstalling a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables
revision history Issue Date Reason for Change Related literature SRP-004-136 Accessing All-Dielectric DX Armored Fiber Optic Cables Admonishments 1. General This procedure provides instructions for installing
More informationMiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions
MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures 004-273-AEN, Issue 2 Table of Contents 1. General.... 1 2. Precautions.... 1 2.1 Cable Handling Precautions...
More information3M Better Buried Compound Compression Closure System
3M Better Buried Compound Compression Closure System Instructions March 2016 78-0015-2948-2-A Contents: 1.0 General...3 2.0 Kit Contents...3 3.0 Closure Selection Guide...4 4.0 LHS End Cap Installation...5
More informationFOSC 400 A4 Fiber Optic Splice Closure
FOSC 400 A4 Fiber Optic Splice Closure I N S T A L L A T I O N I N S T R U C T I O N 1. General Product Information This installation practice provides instructions for installing Tyco Electronics FOSC
More informationRetractaNet XS. Extractable Solutions for OSP. October 2012
RetractaNet XS Extractable Solutions for OSP October 2012 OSP Solutions RetractaNet XS Solution Simple concept reduces the need for skilled labor for installation Easy direct buried deployment in soft
More informationUNSIGNED HARDCOPY NOT CONTROLLED
SUBJECT: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS REFERENCES Cable and Harness Making Manager, Hardware Engineering Maintenance Revision Establishes requirements for the fabrication and inspection
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS Multiplexer Enclosure and Cabling December 00 Figure - Trase Unit and Multiplexer Enclosure BNC Coaxial Cables From s (in order) MULTIPLEXER MODEL: 00B R / / / / / / / 9 0 9 0 Multiplexer
More information100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual
100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More information3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series
3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series Instructions Voltage Rating: 1000 V, Temperature Rating: 90 C Kit Contents 78-R1 78-R2 78-R3 78-R4 78-R5 Sleeve Set 1 1 1 1
More informationCrane Systems Extension Reel Cable Guide Hardware Kit
Purpose Extension Reel Cable Guide Hardware Kit Greer Number K056005 The Extension Reel Cable Guide Hardware Kit is used to control the reel-off cable along the telescoping boom and the signal cable routed
More informationVIP-35 Manual. Video Inspection Probe
VIP-35 Manual Video Inspection Probe Foreword Thank you for purchasing our products. Before assembly and use, make certain that all of the parts you have ordered are present. Check the packaging carefully
More informationFTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.
FTTH & FITH Discreet optical fiber solutions from the network connection point to the set-top box www.omelcom.com FIBER: THE FUTURE IS HERE The past several years have seen major progress in the penetration
More informationSJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1
Fiber Optic Splice Closure 1. Introduction 1.1 General SAMJIN s SJOF-BS604B protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct buried
More informationGENUINE PARTS. SIRIUS Under Glass Antenna Kit
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Pathfinder (2006-2007) 3. PART NUMBERS: XM Tuner Kit 999U9-AS005 SIRIUS Tuner Kit 999U9-AS006
More information4320 SS-25 Self-Strip Terminating Block
4320 SS-25 Self-Strip Terminating Block Instructions May 2002 78-8130-7677-1 1.0 General The 3M 4320 SS-25 Self-Strip Terminating Block is a factory stubbed, self-stripping connecting block designed for
More information3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter
3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter Instructions January 2010 3 1.0 General 1.1 The 3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter(s) protects, organizes and stores
More informationPublic Works Division Lighting District Fiber Optic Specifications April 2009
Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks
More informationFOSC 400 C5 & D5 Fiber Optic Splice Closures
FOSC 400 C5 & D5 Fiber Optic Splice Closures I N S T A L L A T I O N I N S T R U C T I O N 1. General Product Information The FOSC 400 C5 and D5 closures are combination cable closures and splice organizers,
More information2178 L/S Series Fiber Optic Splice Cases and Accessories
2178 L/S Series Fiber Optic Splice Cases and Accessories The 3M 2178 Fiber Optic Splice Case family has always given you great protection for fiber optic connections. Now, the addition of 3M 2178-L/S Series
More informationCABLE MANAGEMENT PRODUCTS Cable Managers & Accessories
CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories Evolution Cable Management Page 5-3 Velocity Cable Management Page 5-8 Velocity Standard Pack Page 5-12 Vertical Cable Management Page 5-13 Global
More information