XT IEC Power Control Combination Motor Controllers
|
|
- Benedict Pierce
- 5 years ago
- Views:
Transcription
1 7 Product Family Overview May 007 Contents Description Page Standards and Certifications Catalog Selection Product Selection Accessories Technical Data and Specifications Dimensions Reference Data XT Combination Motor Controller and Manual Motor Controller Product Description The new Cutler-Hammer XT IEC Open Non-reversing and Reversing Manual Motor Controllers from Eaton s electrical business combine a Manual Motor Protector with an IEC Contactor(s) to provide a complete motor protection solution by combining motor disconnect function, thermal overload protection, magnetic short circuit protection and remote control operation in one compact, assembled unit. These assembled Manual Motor Controllers cover motors with FLA ratings from 0.A to 6A. The UL 08 Type F labeled Combination Motor Controller (CMC) includes a Line Side Adapter (LSA). These assembled cover motors with FLA ratings from 0.A to A. Application Description The XT IEC Non-reversing and Reversing Manual and Combination Motor Controllers can be used in the following applications: XTSC and XTSR Manual Motor Controller for Single and Multi Motor Panels The preassembled XT Manual Motor Controllers (MMC) combine a Manual Motor Protector, a Wiring Connector Link and IEC Contactor. MMCs can also be field installed with separate MMP, WCL and Contactor(s). An IEC magnetic has been added to allow for remote operation of the motor circuit. XTFC and XTFR Combination Motor Controller (UL 08, Type F), for Single and Multi Motor Panels The preassembled IEC combine a Line Side Adapter, Manual Motor Protector, Wiring Connector Link and IEC Contactor. The XTPR Manual Motor Protectors are UL listed as UL 08, Type E Self- Protected Manual Combination Starters. This UL listing allows these devices to be used in motor circuits without having to add separate branch short circuit protection. An IEC magnetic has been added to allow for remote operation of the motor circuit. Group Motor Installations Since the Manual Motor Protectors (Manual Combination Starters) are UL listed for Group Motor Installations, the IEC Manual Motor Controllers provide a compact, assembled package for Group Motor Installations up to 600V. For Group Installations (in-panel SCPD) applying the traditional / tap rule, the Manual Motor Protectors and may be used on 80V Delta systems along with 80Y/77V and 600Y/7V slash rated Wye systems. For Group Installations, applying the more recent / tap conductor rule, a maximum 0V Delta is permitted or 80Y/77V and 600Y/7V slash rated Wye systems. For actual UL 08 Type E/F applications (out-of-panel upstream feeder Short- Circuit Protective Device [SCPD] only), a maximum 0V Delta is permitted or 80Y/77V and 600Y/7V slash rated Wye systems. For Manual At Motor Disconnect applications, a maximum 0V Delta is permitted or 80Y/77V and 600Y/7V slash rated Wye systems. Features ON/OFF rotary handle with lockout provision Visible trip indication Test trip function Motor applications from 0.A to 6A Class overload protection Built-in heater and magnetic trip elements to protect the motor Phase loss sensitivity Type coordination Ambient compensated up to C [0 F] Control inputs located at front of starter for easy access and wiring Wide range of coils DIN Rail mount XTSC BB_ Mounting plates XTSC BC_, XTSC D motor controllers Adjustment dial for setting motor FLA Short circuit trip at times the maximum setting of the FLA adjustment dial UL 08 Type F CMC High Fault Short Circuit Ratings: Refer to Table. NO-NC Auxiliary Contact as standard on Manual Motor Controller and Combination Motor Controller CA00700E
2 May 007 Product Family Overview 7 Standards and Certifications UL 08 Type F Combination Motor Controller Table. MMC and CMC Applications XT IEC Manual & IEC Type Approved per IEC UL Listed File No. E8 CE Mark Group Installation Using the in-panel Main SCPD and an MMC without a factory assembled LSA. UL 08 Type F Combination Motor Controller Only Upstream Feeder SCPD required with factory assembled LSA; no dedicated in-panel Main SCPD for CMC. Note: For Type Coordination of MMCs, see Tables 7 through on Pages and 00. Protection in Different Controller Types A UL 08 Type E Self-protected Manual Combination Starter/Motor Controller consists of a single device having integral short circuit protection, a main set of contacts, motor overload protection, and may also include a UL listed Line Side Adapter (see Table ). This type of controller is a legitimate short circuit protective device and disconnect means for the downstream motor. It does require an upstream feeder short circuit protective device, but does not require a dedicated branch circuit protection or a disconnect means if used with a Line Side Adapter. A UL 08 Type E rating means that the unit clears a fault and does not experience any welding of the power poles. A UL 08 Type E self-protected manual motor controller will remain fully functional should a short circuit within its ratings occur. E.g. XTPR. An XT UL 08 Type F Self-protected Combination Motor Controller consists of a UL Listed Type E Self-protected Manual Combination Starter/Motor Controller, a UL Listed Contactor, and a UL Listed Line Side Adapter (see Table ). While the UL 08 Type E self-protected manual motor protector of this combination motor controller device is a legitimate short circuit protective device and disconnect means for the downstream motor, the is not self-protected. E.g. XTFC, XTFR. In addition, as a complete assembly or modular components, the device should have Type Coordination certification. Type Coordination means the Starter or the Controller must exhibit little or no damage following a major short circuit fault and should be able to be returned to proper service without replacing any parts. Line Side Adapter (LSA) Not required Manual Motor Controller XTSC / XTSR Line Side Adapter (LSA) Required Factory Assembled Combination Motor Controller XTFC / XTFR SCPD = Short Circuit Protective Device (Circuit Breaker, Fuses). MMC = Manual Motor Controller Reference: Technical Paper AP0000E. Note: Line Side Adapters are not required for non-u.s. applications. Most countries outside of the U.S. classify the MMP as a thermal magnetic circuit breaker. CA00700E
3 76 Catalog Selection May 007 Catalog Selection Table. Catalog ing System X T S C 0 B B A Design XT = Type SC = Manual Motor Controller FVNR SR = Manual Motor Controller FVR FC = Combination Motor Controller, UL 08 Type F FVNR FR = Combination Motor Controller, UL 08 Type F FVR Rated Current of MMP B-Frame D-Frame P6 = 0.6A P = 0.A P0 = 0.0A P6 = 0.6A 00 = A P6 =.6A P =.A 00 = A 6P = 6.A 0 = A 0 = A 06 = 6A 00 = 0A 0 = A 0 = A 06 = 6A 0 = A 0 = A 00 = 0A 00 = 0A 08 = 8A 06 = 6A Coil Voltage A = V 0 Hz, 0V 60 Hz B = 0V 0 Hz, 0V 60 Hz C = V 0 Hz, 80V 60 Hz D = 0V 0 Hz, 600V 60 Hz E = 08V 0 Hz F = 0V 0 Hz G = 0V 0 Hz, 0V 60 Hz H = 0V 0 Hz, 77V 60 Hz L = 80V 0 Hz, 0V 60 Hz N = 00V 0 Hz P = 80V 60 Hz R = V 0/60 Hz T = V 0/60 Hz U = V 0 Hz W = V 0 Hz, 8V 60 Hz Y = 8V 0 Hz AD = 0V DC BD = 0V DC RD = V DC TD = V DC WD = 8V DC Frame Size Contactor B = mm, 7 to A C = mm, 8 to A D = mm, 0 to 6A Frame Size MMP B = mm, 0. to A D = mm, 6 to 6A XTSC FVNR Frame B MMP & Frame B Contactor XTSC FVNR Frame B MMP & Frame C Contactor XTSC FVNR Frame D MMP & Frame C Contactor XTSC FVNR Frame D MMP & Frame D Contactor XTSR FVR Frame B MMP & () Frame B Contactors XTSR FVR Frame B MMP & () Frame C Contactors XTSR FVR Frame D MMP & () Frame C Contactors XTSR FVR Frame D MMP & () Frame D Contactors CA00700E
4 May 007 Product Selection 77 Product Selection Table. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor FLA Adjustment Range / Overload Release I r (Amps) Short- Circuit Release I rm (Amps) Maximum Motor Ratings P Maximum Motor kw Rating AC- P (kw) Maximum hp Rating P (hp) Assembled Manual Motor Controller Three-Phase Three-Phase Non-reversing Reversing 0 0V 80 V 00V V 00V 0V 80V 600V Catalog AC Coil DC Coil Catalog AC Coil DC Coil Frame B MMP + Frame B Contactor Frame B MMP + Frame C Contactor Frame D MMP + Frame C Contactor Frame D MMP + Frame D Contactor Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kw, hp) are for reference only. For additional voltages not listed, see Table 8 on Page 8. In this range, calculate motor rating according to rated current. Specified values to NEC Table 0-0. Underscore (_) indicates Magnetic Coil Suffix required. See Table on Page 7. / XTSCP6BB_ XTSCPBB_ XTSCP0BB_ XTSCP6BB_ XTSC00BB_ XTSCP6BB_ XTSCPBB_ XTSC00BB_ XTSC6PBB_ XTSC0BB_ XTSC0BB_ XTSC06BB_ XTSC06BC_ XTSC00BC_ XTSC0BC_ XTSC0BC_ XTSC06DC_ XTSC0DC_ XTSC0DC_ XTSC00DD_ XTSC00DD_ XTSC08DD_ XTSC06DD_ XTSRP6BB_ XTSRPBB_ XTSRP0BB_ XTSRP6BB_ XTSR00BB_ XTSRP6BB_ XTSRPBB_ XTSR00BB_ XTSR6PBB_ XTSR0BB_ XTSR0BB_ XTSR06BC_ XTSR00BC_ XTSR0BC_ XTSR0BC_ XTSR06DC_ XTSR0DC_ XTSR0DC_ XTSR00DD_ XTSR00DD_ XTSR08DD_ XTSR06DD_ ,00.,6.,86.,., ,08.,.,.,88.,88. Notes: The assembled Manual Motor Controller (MMC) consists of an XTPR Manual Motor Protector (MMP) and an XTCE. For Frame B MMP + Frame B Contactor assemblies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The s are supported mechanically with a mechanical connection element (included in, XTPAXRPCRB). For 6A and above, the assembly is mounted via a DIN Rail Adapter Plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection is made with electrical contact modules (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. For detailed component lists, see Table, Page 8. Service Factor Settings: Setting I r of current scale in dependence of load factor: SF =. I r = x I n mot SF = I r = 0. x I n mot Single-phasing sensitivity to IEC/ EN 607--, VDE 0660 Part. M ~ Figure 8. XTSC Manual Motor Controller M ~ Figure. XTSR Manual Motor Controller Accessories Page 7 Technical Data Page 8 Discount Symbol CD7 CA00700E
5 78 Product Selection May 007 Table. XTFC and XTFR (CMC), UL08 Type F Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor + Required Line Side Adapter FLA Adjustment Range / Overload Release I r (Amps) Short- Circuit Release I rm (Amps) Maximum Motor Ratings Maximum Motor kw Rating AC- P (kw) Maximum hp Rating P (hp) Assembled Combination Motor Controller Three-Phase Three-Phase Non-reversing Reversing 0 0V 80 V 00V V 00V 0V 80V 600V Catalog AC Coil DC Coil Catalog AC Coil DC Coil Frame B MMP + Frame B Contactor Frame B MMP + Frame C Contactor Frame D MMP + Frame C Contactor / Frame D MMP + Frame D Contactor XTFC00DD_ XTFR00DD_,7.,6. Select by full load amperes. Maximum Motor Ratings (kw, hp) are for reference only. For additional voltages not listed, see Table 8 on Page 8. In this range, calculate motor rating according to rated current. Specified values to NEC Table 0-0. Underscore (_) indicates Magnetic Coil Suffix required. See Table on Page XTFCP6BB_ XTFCPBB_ XTFCP0BB_ XTFCP6BB_ XTFC00BB_ XTFCP6BB_ XTFCPBB_ XTFC00BB_ XTFC6PBB_ XTFC0BB_ XTFC0BB_ XTFC06BB_ XTFC06BC_ XTFC00BC_ XTFC0BC_ XTFC0BC_ XTFC06DC_ XTFC0DC_ XTFC0DC_ XTFRP6BB_ XTFRPBB_ XTFRP0BB_ XTFRP6BB_ XTFR00BB_ XTFRP6BB_ XTFRPBB_ XTFR00BB_ XTFR6PBB_ XTFR0BB_ XTFR0BB_ XTFR06BC_ XTFR00BC_ XTFR0BC_ XTFR0BC_ XTFR06DC_ XTFR0DC_ XTFR0DC_ , ,0.,. Notes: The assembled Combination Motor Controller (CMC) consists of an XTPR Manual Motor Protector (MMP) and an XTCE and a required Line Side Adapter. For Frame B MMP + Frame B Contactor assemblies, the XTFC and XTFR can be mounted directly on DIN rail without an adapter. The s are supported mechanically with a mechanical connection element (included in, XTPAXRPCRB). For 6A and above, the assembly is mounted via a DIN Rail Adapter Plate (XTPAXTPCPC, XTPAXT- PCPD) and the electrical connection is made with electrical contact modules (XTPAX- ECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. For detailed component lists, see Table 0, Page 8. Service Factor Settings: Setting I r of current scale in dependence of load factor: SF =. I r = x I n mot SF = I r = 0. x I n mot Single-phasing sensitivity to IEC/ EN 607--, VDE 0660 Part. M ~ Figure. XTFC Combination Motor Controller M ~ Figure. XTFR Combination Motor Controller Discount Symbol CD7 CA00700E
6 May 007 Accessories 7 Table. AC and DC Coil Suffixes Coil Voltage Suffix Code Frame B Contactors V 0 Hz, 0V 60 Hz A 0V 0 Hz, 0V 60 Hz B 0V 0 Hz F V 0/60 Hz T V DC TD V 0 Hz, 80V 60 Hz 0V 0 Hz, 600V 60 Hz 08V 60 Hz 0V 0 Hz, 0V 60 Hz 0V 0 Hz, 77V 60 Hz 80V 0 Hz, 0V 60 Hz 00V 0 Hz 80V 60 Hz V 0/60 Hz V 0 Hz V 0 Hz, 8V 60 Hz 8V 0 Hz 0V DC 0V DC V DC 8V DC With DC Operation: Integrated diode-resistor combination, coil rating.6w. For indicated coils, price adder of % must be applied to the MMC list price in Tables and. Accessories Line Side Adapters C D E G H L N P R U W Y AD BD RD WD Coil Voltage Frame C and D Contactors Suffix Code V 0 Hz, 0V 60 Hz A 0V 0 Hz, 0V 60 Hz B 0V 0 Hz F V 0/60 Hz T 7V DC TD Line Side Adapters are required for use with XTPR MMPs only when used as Type E Self-Protected Manual Combination Starters or as part of XTFC or XTFR Type F. Not required for Group Installation. Table 6. Line Side Adapters Description V 0 Hz, 80V 60 Hz 0V 0 Hz, 600V 60 Hz 08V 60 Hz 0V 0 Hz, 0V 60 Hz 0V 0 Hz, 77V 60 Hz 80V 0 Hz, 0V 60 Hz 00V 0 Hz 80V 60 Hz V 0/60 Hz V 0 Hz V 0 Hz, 8V 60 Hz 8V 0 Hz C D E G H L N P R U W Y V DC AD 00 0V DC BD V DC RD 8 60V DC WD Catalog For use with Frame B MMPs (up to A) XTPAXLSA 6. For use with Frame D MMPs (up to 0A) XTPAXLSAD 0.0 Discount Symbol CD7 CA00700E
7 80 Accessories May 007 Combination Connection Kits Combination Connection Kits include the necessary components to field assemble a Manual Motor Controller with an MMP (XTPR) and Contactor (XTCE). Table 7. Combination Connection Kits For Use with Description Std. Pack Catalog Non-reversing Starters XTPR...B + XTCE...B Mechanical connection element for XTPR...B and Main current wiring between XTPR...B and in tool-less plug connection Cable guidance Use as auxiliary switch XTCEXFAT_. Control cable guidance: max. 6 cables up to. mm external diameter or cables up to. mm external diameter..7 XTPR...B + XTCE...C XTPAXTPCC.7 XTPR...D + XTCE...D DIN rail adapter plate XTPAXTPCD.0 Main current wiring between XTPR and Reversing Starters XTPR...B + XTCE...B0_ XTPR...B + XTCE...C Mechanical connection element for XTPR...B and Reversing starter main current wiring in tool-less plug connection Control cables for electrical interlocking in toolless plug connection: KM: A KM: KM: KM: A KM: A KM: A Cable guidance Use as auxiliary switch XTCEXFAT_. Control cable guidance: max. 6 cables up to. mm external diameter or cables up to. mm external diameter. DIN rail adapter plate Reversing starter main current wiring 8.0 XTPAXTPCRC 8.0 Star-Delta Starter Sets XTPR...B + XTCE...B DIN rail adapter plate Main current wiring between XTPR...B and Electrical interlock between delta and star Use as auxiliary switch XTCEXFAT_ XTPAXSDSB XTPR...B + XTCE...C DIN rail adapter plate Main current wiring between XTPR...B and XTPAXSDSC 0.00 Discount Symbol CD7 CA00700E
8 May 007 Accessories 8 Combination Connection Kits Table 7. Combination Connection Kits (Continued) For Use with Description Std. Pack Catalog Electric Contact Module DIN Rail Adapter Plates XTPR...B + XTCE...C XTPR...D + XTCE...D Main current wiring between XTPR...B and Use only in combination with busbar adapter Main current wiring between XTPR...D and Use only in combination with busbar adapter mm wide adapter plate with one DIN rail Connection element for side-by-side positioning of further plates XTPAXECMC.80 XTPAXECMD 7. XTPAXTPCPB.7 XTPR...B + XTCE...C XTPAXECMC mm wide adapter plate with two DIN rails Connection element for side-by-side positioning of further plates XTPAXTPCRPB.00 XTPAXECMD XTPR...D + XTCE...C XTPR...D + XTCE...D mm wide adapter plate with two DIN rails Connection cams for further plates For use with reversing and star-delta starters XTPAXTPCPD. Lateral Module Connection Element Can be grouped on the DIN rail adapter Expansion of the mounting width by mm listed is for a quantity of one (). Orders must be placed in multiples of package quantity listed. XTPAXLM 6.7 For connection of several DIN rail adapters 0 XTPAXCNE. Discount Symbol CD7 CA00700E
9 8 Technical Data and Specifications May 007 Technical Data and Specifications Table 8. Manual and Motor Ratings Assembled Controller FLA Adjustment Range / AC- P (kw) Overload Release Maximum Motor Ratings P Maximum Motor kw Rating Maximum hp Rating P (hp) Three-Phase Single-Phase Three-Phase Non-reversing Reversing V 00V 660 V 00V 08V 0V 00V 08V 0V 80V 600V I r (Amps) 0V V 60V XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations XTSC & XTSR Frame B MMP + Frame B Contactor XTSCP6BB_ XTSCPBB_ XTSCP0BB_ XTSCP6BB_ XTSC00BB_ XTSCP6BB_ XTSRP6BB_ XTSRPBB_ XTSRP0BB_ XTSRP6BB_ XTSR00BB_ XTSRP6BB_ XTSCPBB_ XTSC00BB_ XTSC6PBB_ XTSC0BB_ XTSC0BB_ XTSC06BB_ XTSRPBB_ XTSR00BB_ XTSR6PBB_ XTSR0BB_ XTSR0BB_ XTSC & XTSR Frame B MMP + Frame C Contactor XTSC06BC_ XTSR06BC_ 6 XTSC00BC_ XTSR00BC_ 6 0 XTSC0BC_ XTSR0BC_ 0 XTSC0BC_ XTSR0BC_ XTSC & XTSR Frame D MMP + Frame C Contactor XTSC06DC_ XTSR06DC_ 6 XTSC0DC_ XTSR0DC_ 6 XTSC0DC_ XTSR0DC_ XTSC & XTSR Frame D MMP + Frame D Contactor XTSC00DD_ XTSC00DD_ XTSC08DD_ XTSC06DD_ XTSR00DD_ XTSR00DD_ XTSR08DD_ XTSR06DD_ XTFC & XTFR (CMC), UL08 Type F XTFC & XTFR Frame B MMP + Frame B Contactor XTFCP6BB_ XTFCPBB_ XTFCP0BB_ XTFCP6BB_ XTFC00BB_ XTFCP6BB_ XTFCPBB_ XTFC00BB_ XTFC6PBB_ XTFC0BB_ XTFC0BB_ XTFC06BB_ XTFRP6BB_ XTFRPBB_ XTFRP0BB_ XTFRP6BB_ XTFR00BB_ XTFRP6BB_ XTFRPBB_.6. XTFR00BB_. XTFR6PBB_ 6. XTFR0BB_ 6. XTFR0BB_ 8 6 XTFC & XTFR Frame B MMP + Frame C Contactor XTFC06BC_ XTFC00BC_ XTFC0BC_ XTFC0BC_ XTFR06BC_ XTFR00BC_ XTFR0BC_ XTFR0BC_ XTFC & XTFR Frame D MMP + Frame C Contactor XTFC06DC_ XTFC0DC_ XTFC0DC_ XTFR06DC_ XTFR0DC_ XTFR0DC_ XTFC & XTFR Frame D MMP + Frame D Contactor XTFC00DD_ XTFR00DD_ Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kw, hp) are for reference only. In this range, calculate motor rating according to rated current. Specified values to NEC Table 0-0. Underscore (_) indicates Magnetic Coil Suffix required. See Table on Page /8 / - - /8 / - - /8 / - 7- /8 / - /8 / - 7- /8 / - / /6 / - 7- / /6 / / / Notes: Service Factor Settings: Setting I r of current scale in dependence of load factor: SF =. I r = x I n mot SF = I r = 0. x I n mot Single-phasing sensitivity to IEC/ EN 607--, VDE 0660 Part. CA00700E
10 May 007 Technical Data and Specifications 8 Table. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations Component Bill of Material Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor Assembled Manual FLA Adjustment Range / Motor Controller Overload Release I r (Amps) Non-reversing XTSC Frame B MMP + Frame B Contactor XTSCP6BB_ XTSCPBB_ XTSCP0BB_ XTSCP6BB_ XTSC00BB_ XTSCP6BB_ XTSCPBB_ XTSC00BB_ XTSC6PBB_ XTSC0BB_ XTSC0BB_ XTSC06BB_ XTSC Frame B MMP + Frame C Contactor XTSC06BC_ XTSC00BC_ XTSC0BC_ XTSC0BC_ XTSC Frame D MMP + Frame C Contactor XTSC06DC_ XTSC0DC_ XTSC0DC_ 6 6 XTSC Frame D MMP + Frame D Contactor XTSC00DD_ XTSC00DD_ XTSC08DD_ XTSC06DD_ Reversing XTSR Frame B MMP + Frame B Contactor XTSRP6BB_ XTSRPBB_ XTSRP0BB_ XTSRP6BB_ XTSR00BB_ XTSRP6BB_ XTSRPBB_ XTSR00BB_ XTSR6PBB_ XTSR0BB_ XTSR0BB_ XTSR Frame B MMP + Frame C Contactor XTSR06BC_ XTSR00BC_ XTSR0BC_ XTSR0BC_ XTSR Frame D MMP + Frame C Contactor XTSR06DC_ XTSR0DC_ XTSR0DC_ 6 6 XTSR Frame D MMP + Frame D Contactor XTSR00DD_ XTSR00DD_ XTSR08DD_ XTSR06DD_ Component Catalog s Manual Motor Protector XTPRP6BC XTPRPBC XTPRP0BC XTPRP6BC XTPR00BC XTPRP6BC XTPRPBC XTPR00BC XTPR6PBC XTPR0BC XTPR0BC XTPR06BC XTPR06BC XTPR00BC XTPR0BC XTPR0BC XTPR06DC XTPR0DC XTPR0DC XTPR00DC XTPR00DC XTPR08DC XTPR06DC XTPBP6BC XTPRPBC XTPRP0BC XTPRP6BC XTPR00BC XTPRP6BC XTPRPBC XTPR00BC XTPR6PBC XTPR0BC XTPR0BC XTPR06BC XTPR00BC XTPR0BC XTPR0BC XTPR06DC XTPR0DC XTPR0DC XTPR00DC XTPR00DC XTPR08DC XTPR06DC Combination Connection Kit XTPAXTPCC XTPAXTPCC XTPAXTPCC XTPAXTPCC Contactor XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE007B_ XTCE00B_ XTCE0B_ XTCE0B_ XTCE08C_ XTCE0C_ XTCE0C_ XTCE0C_ Manual Motor Protector Auxiliary Contact Underscore (_) indicates Magnetic Coil Suffix required. See Table on Page 7. The connection between the XTPR DC and the XTCE C... will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCPD). The reversing connection between the XTPR DC and the () XTCE C s will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN Rail Adapter Plate (XTPAXTPCPD), and DIN Adapter Connection Element (XTPAXCNE). XTPAXTPCD XTPAXTPCD XTPAXTPCD XTPAXTPCD XTPAXTPCRC XTPAXTPCRC XTPAXTPCRC XTPAXTPCRC XTCE08C_ XTCE0C_ XTCE0C_ XTCE00D00_ XTCE00D00_ XTCE06D00_ XTCE06D00_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE007B_ () XTCE00B_ () XTCE0B_ () XTCE08C_ () XTCE0C_ () XTCE0C_ () XTCE0C_ () XTCE08C_ () XTCE0C_ () XTCE0C_ () XTCE00D00_ () XTCE00D00_ () XTCE06D00_ () XTCE06D00_ CA00700E
1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete motor protection solution by
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control
IEC Contactors and Starters. Product Description Eaton s XT IEC open nonreversing and reversing manual motor controllers combine a manual motor protector with an IEC contactor(s) to provide a complete
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More informationFeatures XT SC 012 B B A
Motor Control and Protection. XT IEC Manual and Combination Motor Controllers Selection XT IEC Manual and Combination Motor Controllers Manual and Combination Motor Controllers Design XT = XT IEC power
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)
80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Manual Motor Protectors Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays....................
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More information1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...
IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........
More information59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.
.1 Motor Control and Protection Product Overview Selection Guide Description Definite Purpose XT IEC Miniature XT IEC Page 65 Page 69 Page 71 Type Definite purpose IEC IEC Approvals UL Recognized, CSA,
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationXT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...
XT Line Replacement s.1 Freedom Line............................................ A200 Line............................................... Lighting Contactor Magnetic.2 IEC Contactors and Starters XT Line..................................................3
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationTeSys circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationSelection guide siemens.com/sirius-modular-system
SIRIUS modular system Selection guide siemens.com/sirius-modular-system Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement
More informationand Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors
C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,
More informationand Refrigeration Institute). CAQ7 Capacitor Switching Contactors
SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationAgency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationBulletin 190 Compact. Combination Starters
0Circuit reaker ulletin 10 ulletin 10 Compact Combination Starters Power Range 0.1...45 ulletin 10E Modular Eco Starters ulletin 10S Pre-wired Compact Starters Uses ulletin 140M Motor Protectors and ulletin
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationBulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page
3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD
. Selection XT Relays Product Line Prefix XT = XT IEC power control XT Timers Product Line Prefix XT = XT IEC power control Product Family Code RM = Mini IEC control relay RE = IEC control relay Product
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationLC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More information.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and
.1 Product Overview.............................................. Relays and Timers.............................................. Miniature Controls.............................................. Contactors
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationAccessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.
NSB00 K ) K ) K ) Auxiliary switch block, Contactors,. kw RT RT RT / front RH-... /0 Contactors,. kw RT RT RT / Surge suppressors RT -.... /, / auxiliary switch block, -phase feeder front RT -G. / terminals
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationContactors and Contactor Assemblies
Terminal designations according to EN 50 012 3RT10 1 contactors Ident. no. 10E 01 Sizes S0 to S12 Terminal designations according to EN 50 012 3RT10 2 to 3RT10 7, 3RT12, 3RT14 contactors 3RT10 1 contactors
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationLC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device
More informationData sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286
CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 100-G IEC Contactors
Bulletin G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking Mechanical latching Meets IEC,
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCatalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3
PowerPact Multistandard Catalogue numbers Functions and characteristics A-1 Installation recommendations B-1 Dimensions C-1 Wiring diagrams D-1 Additionals characteristics E-1 H-Frame, J-Frame unit-mount
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil
Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 305 AC Starters
Bulletin 305 AC Starters Bulletin 305 NEMA AC Starters NEMA sizes 0 2 Cost saving design E1 Plus electronic overload relays Compact size Bulletin 305 reversing starters are most commonly used for full-voltage
More informationDefinite Purpose Contactors
Definite Purpose Contactors Your order must include: 1) complete cat. no. of selected contactor, and 2) auxiliary contacts, if required. 20/25 FLA 1 and 2 Pole 1-Pole Contactor with Shunt 2-Pole Contactor
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationBulletin 100-G IEC Contactors
Bulletin 100-G IEC Contactors Bulletin 100 G IEC Contactors 315...710 kw, 400V 350 900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking
More informationSystems Pow-R Breakers Renewal Parts and Accessories
Systems Pow-R Breakers Renewal Parts and Accessories Renewal Parts RP01301013E Effective February 2006 Supersedes RPD29-890A pages 1 16 dated, March 2000 Cutler-Hammer SPB 100, 65 and 50 Series Contents
More informationKinetix Application Note
Applying 2094 LIM Modules to Multiple Loads Kinetix Application Note PURPOSE This document addresses application cases where it is desired to utilize a single 2094 LIM module to supply three phase power
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationSITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.
SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.
More informationI r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63
Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC
More informationYour order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories
Bulletin 100-M Miniature Contactors Compact Size Uniform Panel Mounting Dimensions Full oltage Non-Reversing and Reversing Contactors 5, 9, and 12 A Contactors Compatible with Bulletin 193-E solid-state
More informationProtection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More information3AH3 Vacuum Circuit-Breakers
Catalog HG 11.03 Edition 2018 3AH3 Vacuum Circuit-Breakers Medium-Voltage Equipment siemens.com/3ah3 2 3AH3 Vacuum Circuit-Breakers Siemens HG 11.03 2018 R-HG11-373.tif Contents 3AH3 Vacuum Circuit-Breakers
More informationDC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.
HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More informationI r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100
Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationBulletin 150, 154 Softstarters Quick Selection Table
Bulletin 50, 54 Quick Selection Table Type Current Range Bulletin No. 50 50 50 SMC-3 Controller 85 A SMC-Delta Controller 47 A SMC Flex Controller 54 480 A Soft Start Kickstart Current Limit Dual Ramp
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationProduct Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)
Circuit Breakers BZM Product Information Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A) BZM1 & BZM2 & BZM3 Accessories Optimum and Efficient Protection
More informationOPTOTRONIC Intelligent
OPTOTRONIC Intelligent Compact constant current LED drivers Dimmable DALI Areas of application _ Installation in emergency lighting systems according to IEC 61347-2-13, appendix J _ Suitable for use in
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL
Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)
More informationDirect PWM. 1000/2000 Series POWERBLOK MODULE
Direct PWM 1000/2000 Series POWERBLOK MODULE Features A universal servo-drive integrated on a Power Hybrid Module. Designed for direct PWM Servo Control Designed for use with Deta Tau's PMAC controllers
More informationOPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.
OPTOTRONIC FIT inear / Area Constant Current Non dimmable Areas of application Installation in emergency lighting systems according to IEC 61347-2-3, appendix J Suitable for installation in emergency lighting
More informationVariable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives
s Three-phase supply voltage: 200...240 V 50/60 Hz Wall-mounting drives ATV630D11M3 ATV630D15M3 ATV630D30M3 200...240 V IP 21/UL Type 1 drives Motor Line supply Power indicated on rating plate (2) Line
More information