1 Revision.0 Parts List Mini
2
3 Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 Products included... 3 The data plate...3 Exploded Views Spare Parts Mini Parts List
4 Introduction Introduction Purpose of this manual The purpose of this manual is to provide necessary information on spare parts and accessories order. Disclaimer Always use genuine Grindex parts. The use of other spare parts or accessories can invalidate any claims for warranty or compensation. Grindex does not take any responsibility for damages that are caused by the use of non-original parts. For more information, contact your local sales and service representative. Data for ordering spare parts The following information is needed for spare part orders: Serial number of the product Part number Quantity of bulk material, see * in tables Specially approved products Qualification of personnel Only Grindex or Grindex-authorized service personnel may undertake repair work on Ex-approved products. Dimensional accuracy inspection Spare parts marked with (Ex) after the part number are subject to dimensional accuracy inspection Mini Parts List
5 Product Description Product Description Products included The data plate Pump model Standard EX MSHA Drainage Sludge Mini X X Introduction The data plate The data plate is a metal label located on the main body of the pump. The data plate lists key product specifications WS006202A. Pump model 2. Serial number 3. Phase; type of current; frequency 4. Product weight 5. Maximum capacity 6. Maximum submergence 7. Maximum head 8. Degree of protection 9. Read installation manual 0. Thermal class. International standard 2. Maximum power consumption 3. Country of origin 4. Rated current 5. Rated voltage Product approvals for hazardous locations Mini Parts List 3
6 Exploded Views Exploded Views O-RING KIT FLOAT SWITCH KIT BASIC REPAIR KIT B_expl_view_ Mini Parts List
7 Spare Parts Spare Parts Pos. No Part. No Denomination Hex.socket hd screw M6X80-A Motor cable unit 532.U +H07RN-F 3X MM2 H07RN-F 3x 8,60-0mm L= 0m Supply connection: Plug IEC 83:975 C Motor cable unit H07RN-F 3x 8,60-0mm L= 0m Supply connection: Plug (2P+J) SEV 0 S Motor cable unit SOOW-6AWG/3 5V USA CDN Motor cable unit SOW-6AWG/3 230V USA CDN Motor cable unit H07RN-F 3X MM2 0V GB Motor cable unit H07RN-F 3X MM2 230V GB Motor cable unit H07RN-F 3X MM2 230V AUS SOW 6AWG/3 9,78-0,90mm L= 6m Supply connection: Plug IEC 83:975 A5-5 SOW 6AWG/3 9,78-0,90mm L= 6m Supply connection: Plug IEC 83:975 A6-5 H07RN-F 3x 8,70-9,30mm L= 0,60m Supply connection: Plug for FGB (2P+E), fuse 6A, 0-5V H07RN-F 3x 9 L= 9,50m Supply connection: Plug for FGB, fuse 3A, V H07RN-F 3x 9 L= 9,50m Supply connection: Plug for FAUS V Plug O-ring 20.0X2.0 NBR Hex.socket hd screw M6X35-A Handle Hex.socket hd screw M8X25-A Plain washer 8-A Discharge connection 2" DN 50 Hose Thread : ISO G2A Outer Second outlet included Discharge connection G2" DN 50 Thread : ISO G2A Outer Quick coupling: Storz DN 50 Hose Thread : ISO G2A Outer Second outlet included Qty/Version Mini Parts List 5
8 Spare Parts Pos. No Part. No Denomination Discharge connection NPSM 2" DN 50 Thread : NPSM 2- /2 Outer Coupling part DN 50 Thread : ISO G2A Outer Quick coupling: Storz Discharge connection DN 50 HOSE DN 50 Hose aluminium Discharge connection DN 50 Thread : ISO G2A Outer aluminium O-ring 52.5X3.0 NBR Data plate Cover unit 3, Air release valve 3,2 - Cover O-ring 49.3X5.7 NBR Capacitor 30 MFD 275V Stator -phase 50 Hz 2- poles 5V Starter unit Stator -phase 50 Hz 2- poles 230V-240V Capacitor 35 MFD 275V Stator -phase 60 Hz 2- poles 5V Capacitor 4 MFD 450V Stator -phase 60 Hz 2- poles 220V-230V Terminal device 48X2X6 MAX.380V 8A Terminal device 54X2X8.5 MAX.380V 8A -phase Cooling jacket Hex.socket hd screw M4X6-A Motor switch 5V 50HZ Stator -phase 50 Hz 2- poles 5V Motor switch 230V 50HZ Stator -phase 50 Hz 2- poles 230V-240V Motor switch 5V 60HZ Stator -phase 60 Hz 2- poles 5V Motor switch 230V 60HZ Stator -phase 60 Hz 2- poles 220V-230V O-ring 99.5X3.0 NBR Stator housing Stator b -phase 50 Hz 2-poles 5V -phase 60 Hz 2-poles 5V Qty/Version Mini Parts List
9 Spare Parts Pos. No Part. No Denomination Stator b -phase 60 Hz 2-poles 220V-230V -phase 50 Hz 2-poles 230V-240V Spring washer 3.5X25X O-ring 26.0X.2 NBR Ball bearing 2X32X Shaft unit Ball bearing 5X35X Bearing housing O-ring 4.5X3.0 NBR O-ring 04.5X3.0 NBR Retaining ring Oil housing Washer Wear protection Torque flow impeller N 50Hz -phase Max ambient temp=40 DC Torque flow impeller N 60Hz -phase Max ambient temp=40 DC Impeller N 50Hz -phase Max ambient temp=40 DC Plain washer Diffuser unit O-ring 0.3X2.4 NBR 39 - Inspection screw Strainer Barrel nut Plain washer 902-6,4X8X, O-ring kit Seal kit Outer seal kit Level regulator kit Level regulator kit Basic repair kit 900, Spring washer 3.5X25X , O-ring 26.0X.2 NBR 900, Ball bearing 5X35X 900, Ball bearing 2X32X0 Qty/Version Mini Parts List 7
10
11
12 Grindex Gesällvägen Sundbyberg Sweden Tel: Fax: Visit our Web site for the latest version of this document and more information The original instruction is in English. All non-english instructions are translations of the original instruction. 204 Grindex _.0_en-US_205-06_GPL.822.2
Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~
Revision 3.0 www.grindex.com Parts List 80.60 Minex ~ 80.7 Minex Lite, Minex 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included...
More informationRevision 3.0 Parts List Salvador 1~, 3~
Revision 3.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data
More informationRevision 2.0 Parts List Minor
Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded
More informationRevision 2.0 Parts List Minette 1~, 3~
Revision.0 www.grindex.com Parts List 80.7 Minette ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3
More informationRevision 1.0 Parts List Salvador 1~, 3~
Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded
More informationRevision 1.0 Parts List Minor
Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...
More informationRevision 1.0 Parts List Mega
Revision.0 www.grindex.com Parts List 824.390 Mega Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. Products included... 3 2.2 The data
More informationRevision 1.0 Parts List Mega
Revision.0 www.grindex.com Parts List 824.400 Mega Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 The data plate...3 Exploded Views...4 Drive
More informationParts List _2.1. Flygt /.890
Parts List 886754_2. Flygt 3069 3069.70/.890 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3
More informationParts List _2.1. Flygt /.190
Parts List 886747_2. Flygt 3069 3069.60/.90 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3
More informationFlygt /190. Parts List
Flygt 3127.160/190 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification
More informationFlygt Handleiding voor installatie, bediening en onderhoud
Flygt 068 Handleiding voor installatie, bediening en onderhoud Table of Contents Table of Contents 1 Introduction... 1.1 Specially approved products... Product Description....1 The data plate.... Approvals...4.
More informationFlygt D 8050, 50 Hz. Technical specification
Flygt D 8050, 50 Hz Technical specification Table of Contents Table of Contents D 8050... 2 Product... 2 Denomination... 2 Process data... 2 Motor data...2 Cable...2 Monitoring equipment... 2 Material...
More informationPhone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h
Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Multistage Pumps 50 Hz Stainless Steel 3-9 m3/h Model Number Explanation Example: 3AMH2B-51 3 = m 3 /h AMH = Series 2 = # of Stages
More informationDewatering. Series description Wilo-Drain STS 65. Submersible sewage pump
Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring
More informationPARTS LIST FOR CM-1250-A/C 1.5 HP
8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR CM-1250-A/C Motor Specs: Pump Oil: Pump Oil Capacity: Nozzle Size: 1.5 HP / 1 Phase / 115 Volts Mi-T-M #AW-4085-0016
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSeries description: Wilo-Drain VC
Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationAristoMig U320w 208/230/400/460/475/500 V 3~ 50/60 Hz With cooling unit and central connection
Spare parts list Edition 060727 Valid for serial no. 310 -xxx -xxx, 445 -xxx -xxx, 620 -xxx -xxx The AristoMig 450 power source is renamed: New name Old name Mig 4500i AristoMig 450 Mig U4500i AristoMig
More informationImmersion Pumps HCT (High Chem) sealless EN
Immersion Pumps HCT (High Chem) sealless 1 6004 EN Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationData sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)
Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Pump curves Wilo-Drain TP 65 E - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 15.0 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationCM MTC PARTS LIST
8650 Enterprise Drive, Peosta IA 52068-0050 319-556-7484 / Fax 319-556-1235 CM-2400-0MTC PARTS LIST ENGINE OIL GRADE: ENGINE OIL CAPACITY: PUMP OIL: PUMP OIL CAPACITY: NOZZLE SIZE: 30W 21 oz. MI-T-M #AW-4085-0016
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationData sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)
Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More informationImmersion Pumps HCT (High Chem) sealless
Immersion Pumps HCT (High Chem) sealless 1-6004-US Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature
More informationSOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)
SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and
More informationOkta 1000, Roots pump without motor
Okta 1000, Roots pump without motor Okta 1000, Roots pump without motor Similar Image High-performance Roots pump with a pumping speed of 590 to 1,775 m 3 /h Without motor (coupling and motor lantern are
More informationMIKRO POWER FACTOR CORRECTION COMPONENTS
MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationSQM40/41 Actuators for air and gas dampers
SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The
More informationRoots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A
3.1 Vacuum generation / / Convection cooled OktaLine Okta 500 with a pumping speed of 280 to 840 m 3 /h: High-performance Roots pump with a pumping speed of 280 to 840 m 3 /h With 3-phase motor, IE2 No
More informationOkta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz
Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dimensions Technical Data Ambient temperature 5-40 C Cooling method, standard
More informationInstallation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.
www.wampfler.com Page 1 of 27 Index Page 1 Basics...4 2 Basic understanding of an IPT -system...5 3 General rules regarding metal parts in close proximity...6 3.1 Envelope free of ferromagnetic material...6
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More information820 NOVA 820 NOVA. 1 Control knob. 2 Pressure regulator cap screw 3 Pilot gas rate adjuster 4 Thermocouple connection
MAIN FEATURES Control knob with Off, Pilot and On positions. Thermoelectric flame supervision device with re-start interlock. Near silent shut-off valve. Servo-controlled pressure regulator. Step opening
More informationR407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C
R407C compressors Semi-hermetic compressors for air-conditioning applications with R407C New: Now up to 35 bar high pressure, 74 C condensing temp. possible Compressors for R407C 35 bar - At a glance At
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More information82540/ /2-way diaphragm valves
> > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid
More informationInstallation and Operating Instructions Electric Vibrators HV/VFL/HF Series
Installation and Operating Instructions Electric Vibrators HV/VFL/HF Series Translation of the Original Instruction Manual Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationPendant Light Fittings Series 6050
> Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket
More information2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors
00/00/400/600 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box
More informationPDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice
PDP Series Positive displacement dosing pump Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI The right dosing choice PDP Series SUPPORTING ELEMENTS OF OUR PRODUCTS Versatility
More informationDuo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz
Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dual-stage, high-performance rotary vane pump with a pumping
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationCM MVC & CM MHC PARTS LIST
8650 Enterprise Drive, Peosta IA 52068 319-556-7484 / Fax 319-556-1235 CM-2400-0MVC & CM-2403-0MHC PARTS LIST (After Serial #215703) Vanguard Engine Oil Grade: Vanguard Engine Oil Capacity: Honda Engine
More informationSeries description: Wilo-Sub TWU 3 HS
Series description: Wilo-Sub TWU 3 HS Design Submersible pump, multistage Application For private water supply from boreholes, wells and rainwater storage tanks For domestic water supply, sprinkling and
More information2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors
00, 00, 400, 600, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 0 975 Cottonwood
More informationDuo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz
Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz Similar Image Dual-stage, high-performance rotary vane pump with a pumping
More informationSP 1U CNC Die sinking EDM
SP 1U CNC Die sinking EDM Scope of Supply Ver. 2011.10 Edited by: Yongjun Liu Authorized by:shenglin Xiang, Gang Li Valid period: from Oct., 2011 to the next version Contents 1. Machine...2 1.1 Mechanical
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationSOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems
SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationSeries description: Wilo-Jet HWJ
Series description: HWJ 2 Design Self-priming water-supply unit Application Water supply Sprinkling Irrigation and spraying Pumping water from wells and out of low-lying tanks Type key Example: H WJ HWJ
More information1.2 EUREKA Series... from page c.14
.2 EUREKA Series................................................................................................. from page c.4 This latest generation of industrial plugs, connectors and socket outlets
More informationLinear flow controls VFC Linear flow controls with actuator IFC
Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or
More informationAdmiss. counterpressure
in survey Multi-layer diaphragm technology High dosing accuracy Safe to run dry High quality materials Leakage-free Low maintenance User-friendly Integrable into automatic processes Manual stroke length
More informationUp to 85% higher Service Life due to efficient sealing method.
Robot Accessories Feeding through Up to 85% higher Service Life due to efficient sealing method. 346 Robot Accessories Feeding through Feeding through DDF 2 Rotary Feed-through Series Size Page DDF 2 348
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationScrew pump Series ALLFUEL AFT
Screw pump Series ALLFUEL AFT Utilization For pumping light and heavy fuel oil. Main field of application ALLFUEL Transfer (AFT) pumps are compact pump sets designed for closed circuit and transfer applications
More informationModel ED 400 Drying and heating chambers Classic.Line with natural convection
Model ED 400 Drying and heating chambers Classic.Line with natural convection BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationInstallation. SAPTF33xx-1xx in the Network. Standard Configuration
SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device
More information8 Installation Equipment
8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationSIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions
DB411/415/422/ DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More informationDuo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz
Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dual-stage, high-performance rotary vane pump with a pumping
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationCME500 SERVICE PARTS
This section contains the parts illustrations and parts lists for the CME500. CME500 ice machines are manufactured in both 115 volt, 60 cycle and 220 volt, 50 cycle. When ordering electrical parts, be
More informationR87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information
Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.
More informationOperating instructions
108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.
More informationAgilent High Capacity RV Pumps & Roots Pumping Systems
Agilent High Capacity RV Pumps & Roots Pumping Systems 2-3 MS-Series Rotary Vane Pumps 4-5 RPS-Series Roots Pumping Systems and RPK-Series Roots Pumping Kits 6-7 Typical Applications 8-15 Pump Models MS-Series
More informationEXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder
EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries
More informationAP2-3 AT2-3/AT2V-3V ATE2/ATE2V
SPARE PARTS LIST ERSATZTEILLISTE LISTE PIÈCES DÉTACHÉES AP2-3 AT2-3/AT2V-3V ATE2/ATE2V 14 17 16 15 14 11 15 11 8 9 12 8 1 3 9 11 12 6 10.1 2 4 5 6 13 7 8 9 12 10.2 2 bar max BY-PASS 2 bar max SUNTEC INDUSTRIES
More informationDuo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz
Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz Similar Image Dual-stage, high-performance rotary vane pump with a pumping
More informationActuators IC 20, IC 40
Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions
More informationGear Pump Units. For single-line lubrication systems
Gear Pump Units 1-1202-US For single-line lubrication systems MFE5-KW3-2 MFE5-BW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationSMALL OIL SEALED PUMPS
SMALL OIL SEALED PUMPS PERFORMANCE YOU CAN RELY ON EM0.7 and.5 Oil Sealed Rotary Vane Pumps 8 RV Oil Sealed Rotary Vane Pumps 86 RV ATEX Oil Sealed Rotary Vane Pumps 94 EM8 and 8 Oil Sealed Rotary Vane
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More information7 Lighting Technology
7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection
More informationBriggs&Stratton 44Q B1
Accessories IPL, Briggs&Stratton 44Q777-1272-B1, 2010-03 Briggs&Stratton 44Q777-1272-B1 Spare parts Ersatzteile Pièces détachées Reserve onderdelen Repuestos Reservdelar 48 SHORT BLOCK 1329 REPLACMENT
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationCircuit-Breakers for Motor Protection Series 8523/8
> Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationProduct Data Sheet 4656 ZW
The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationFlygt Submersible Motor Cables
Flygt Submersible Motor Cables This brochure contains an overview of the Flygt motor cable assortment. The cables are especially designed for submersible use and made of carefully selected materials. The
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More information