EMC Solutions Noise filtering
|
|
- Sharleen Barker
- 5 years ago
- Views:
Transcription
1 Power & Signal Quality TRABTECH EMC Solutions Noise filtering
2 Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability of electrical systems, installations and devices. Phoenix Contact meets these requirements with the comprehensive TRABTECH product range. Specific solutions from surge protection, monitoring, device circuit breakers as well as EMC products offer a constant high power and signal quality for maximum availability. Surge protection Monitoring Device circuit breakers EMC solutions 2 PhoeNix CoNtaCt Services
3 Table of contents Power and signal quality with EMC solutions Interference voltage filters for power supply units and measurement signals Page 4 Combined interference suppression filters with type 3 surge protection Page 5 Interference suppression filters with 1-10 A nominal load current Page 6 Interference suppression capacitor with modular terminal block design Page 7 Reliable signals through interference suppression filters Mechanically or electronically triggered switching operations generate pulse-like and high frequency interference voltages. These voltages are spread unhindered through the network. All devices within this network are affected. Data errors, uncontrolled functions and system crashes occur in data processing devices in particular. Fluorescent lamps EDP systems Relay Mains switch Electrical tools 0.1 to 3 MHz 2 to 3 MHz 0.05 to 20 MHz 0.5 to 25 MHz 0.1 to 1 MHz Typical sources of conducted interference voltages The causes for high-frequency random voltages are numerous and occur in all conceivable fields. PhoeNix CoNtaCt 3
4 Interference voltage filters for power supply units and measurement signals Interference suppression filters reduce conductor-specific high-frequency interference voltages. Devices, particularly in the field of data processing or automation, benefit from a clean power supply. Reliable operation as well as reliable measurement is the result. With floating remote indication contact SURGE FILTER PROTECTION Nominal voltage U N Phases Nominal load current I L Nominal frequency f N Nom. discharge surge current I N (8/20)μs Protection level U P Backup fuse max. in acc. with IEC IEC categories EN type IEC EN UL 1449 Interference suppression filters Functional principle and operating area Functional principle of filter circuits L L PE X Y 1 PE Filtering symmetrical interferences Interference voltages can be filtered X between phase and neutral conductors. Y 2 N N Filtering asymmetrical interferences Relevant opposite, grounded interference Y 1 voltages can be filtered from phase to PE as well as from neutral conductor to PE. Y 2 COMBITRAB X Y Operating area of filters An attenuation curve diagram illustrates the effective workspace of interference suppression filters. According to the symmetrical or asymmetrical filter circuit, the respective frequency-dependent attenuation is legible. Nominal voltage U N Nominal frequency f N Nominal load current I L Nom. discharge surge current I N (8/20)μs Protection level U P Backup fuse max. in acc. with IEC IEC categories EN type Test standards 4 PhoeNix CoNtaCt
5 Combined interference suppression filters with type 3 surge protection SURGE FILTER PROTECTION DIN rail mountable interference suppression filter with integrated device protection, optical diagnostic and status indicator and floating remote indication contact. COMBITRAB Interference suppression filter including device protection with on/off switch, optical-acoustic signaling and potential terminal block. TERMITRAB Combination of interference suppression filter and surge protection for two signal wires with common reference potential. ae symmetrical: ( 100 khz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) ae symmetrical: ( 500 khz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) SFP 1-20/230 AC SFP 1-5/120AC SFP 1-10/120AC SFP 1-15/120AC SFP 1-20/120AC Order No Order No Order No Order No Order No V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 120 V AC 1-phase 20 A ( 40 C) 5 A ( 72 C) 10 A ( 62 C) 15 A ( 52 C) 20 A ( 40 C) 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 5 ka (L-N) 5 ka (L-PE) 3 ka (L-N) 3 ka (L-PE) 1 kv (L-N) 1 kv (L(N)-PE) 450 V (L-N) 450 V (L(N)-PE) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) 20 A (gl gg) III T3 III T3 III T3 III T3 III T3 ae symmetrical: ( 1 MHz / 50 Ω) ae asymmetrical: 3 ( 1 MHz / 50 Ω) asymmetrical 50 Ω asymmetrical 150 Ω CBT-4SFP-10 Order No V AC 50 Hz 60 Hz 10 A ( 40 C) 2.5 ka (L-N) 2.5 ka (L-PE) 650 V (L-N) 1 kv (L(N)-PE) 10 A (autom. 1-pos. thermal) III T3 IEC EN /A11 EN TERMITRAB TT-ST-M-SFP Order No Nominal voltage U N Phases 24 V AC Nominal frequency f N 50 Hz 60 Hz Nominal load current I L 500 ma ( 55 C) Nominal discharge surge current I N (8/20)μs 350 A (L-PE) Protection level U P 80 V (C1 (500 V / 250 A)) (L-PE) Backup fuse max. in acc. with IEC 500 ma (e.g. T in acc. with 127-2/III) IEC categories EN type C1 C3 Test standards IEC PhoeNix CoNtaCt 5
6 Interference suppression filters with 1 to 10 A nominal load current FILTRAB are interference suppression filters for single-phase circuits, which limit both asymmetrical and symmetrical interference voltages. The ideal installation is directly before the device to be protected, as is valid for all filter devices. ae symmetrical: 65 db (1 MHz / 50 Ω) ae asymmetrical: 45 db (1 MHz / 50 Ω) ae symmetrical: 55 db (1 MHz / 50 Ω) ae asymmetrical: 35 db (1 MHz / 50 Ω) FILTRAB NEF 1-1 NEF 1-3 Order No Order No Nominal voltage U N 240 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 1 A ( 40 C) 3 A ( 40 C) Backup fuse max. in acc. with IEC 1 A (gl) 3 A (gl) Test standards IEC EN IEC EN ae symmetrical: (1 MHz / 50 Ω) ae asymmetrical: (1 MHz / 50 Ω) ae symmetrical: 55 db (1 MHz / 50 Ω) ae asymmetrical: 35 db (1 MHz / 50 Ω) FILTRAB NEF 1-6 NEF 1-10 Order No Order No Nominal voltage U N 240 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 6 A ( 40 C) 10 A ( 40 C) Backup fuse max. in acc. with IEC 6.3 A (gl) 10 A (gl) Test standards IEC EN IEC EN PhoeNix CoNtaCt
7 Interference suppression capacitor with modular terminal block design TERMITRAB series filters are feed-through modular terminal blocks with an interference suppression capacitor between the clamping part and DIN rail. The attenuation acts between signal and ground. A separate PE connection is also available. asymmetrical 50 Ω: 500 khz, typical asymmetrical 150 Ω: 100 khz, typical asymmetrical 50 Ω: 2 MHz, typical asymmetrical 150 Ω: 550 khz, typical TERMITRAB TT-SLKK 5-C 12N-230AC TT-SLKK 5-C 3N3-230AC Order No Order No Nominal voltage U N 230 V AC 240 V AC Nominal frequency f N 50 Hz 60 Hz 50 Hz 60 Hz Nominal load current I L 34 A ( 45 C) 34 A ( 45 C) Capacity (conductor-ground) 12 nf 3.3 nf Test standards VDE VDE Accessories: Spacer plate (2.5 mm height adjustment) DP-UKK 3/5 BK, Order No DP-UKK 3/5 BK, Order No Accessories: End cover D-UKK 3/5 BK, Order No D-UKK 3/5 BK, Order No Accessories: Labeling TRABTECH catalog, p. 123 TRABTECH catalog, p A perfect team for high power and signal quality Interference suppression filters (1) are an important measure to increase availability. Devices for residual current monitoring (2) and professional lightning and surge protection (3) increase availability to a maximum. 1 2 Additional information can be found at: PhoeNix CoNtaCt 7
8 Further information on the products presented here and on the world of solutions from Phoenix Contact can be found at Modular Terminal Blocks CLIPLINE 1 Marking Systems, Tools, and Mounting Material CLIPLINE 2 Or contact us directly. Connection Technology for Field Devices and Field Cabling PLUSCON Device Connection Technology and Electronic Housings COMBICON PHOENIX CONTACT GmbH & Co. KG Blomberg, Germany Phone: +49/52 35/3-00 Fax: +49/52 35/ Automation Components and Systems AUTOMATION Power and Signal Quality TRABTECH Signal Converters, Switching Devices, Power Supply Units INTERFACE MNR / Printed in Germany PHOENIX CONTACT 2012
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES COMPANY INTRODUCTION Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for the Asian market. We are the first local electrical switchgear
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationHYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.
More informationI/A Series Hardware Fiber Optic LAN Converter
I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard
More informationGenerator protection relay
Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.
Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.
Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationOPTOTRONIC Intelligent
OPTOTRONIC Intelligent Compact constant current LED drivers Dimmable DALI Areas of application _ Installation in emergency lighting systems according to IEC 61347-2-13, appendix J _ Suitable for use in
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More informationHYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency
More informationODW-621. RS-232 Point-to-point applications
Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to
More informationGV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals
Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationContactors and Contactor Assemblies
Terminal designations according to EN 50 012 3RT10 1 contactors Ident. no. 10E 01 Sizes S0 to S12 Terminal designations according to EN 50 012 3RT10 2 to 3RT10 7, 3RT12, 3RT14 contactors 3RT10 1 contactors
More informationLED Driver Linear / area fixed output
Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationMINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description
Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationContactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122
www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals
More information15 Series - Dimmer
Features Master slave system for multiple load dimming Suitable for incandescent and halogen lighting loads (with or without transformer or electronic supply) Compatible with energy saving (CF or ED) dimmable
More informationDimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control
Kitchen light control Bedroom light control 15 SЕRES iving room light control ighting control in corridors (for hotels, offices and hospitals) FDER reserves the right to alter characteristics at any time
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationGV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals
Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology
More informationAdvantys STB DATA SHEET. Advantys STB Output Module. Description. Features
Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES COMPANY INTRODUCTION Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for the Asian market. We are the first local electrical switchgear
More informationData sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286
CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationGV2P05. Main. Device short name. Device application
Product datasheet Characteristics GV2P05 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2P Circuit breaker Motor Thermal-magnetic
More informationLED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White
Driver LCAI 38/75W TW lp Tunable White Product description 2-channel LED Driver with LI DT8 Output power: 38 W or 75 W Power input on standby < 0.3 W Nominal life-time up to 50,000 h 5-year guarantee Properties
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63
Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC
More informationCAMTO LTD. Arc detecting system DC/AC
CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationLED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data
Product description Dimmable built-in for LED Constant current (with 2 adjustable output channels) Designed for outdoor and street luminaire Output power 2 x 38 W Suitable for mains voltage peaks (burst/surge)
More informationSITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.
SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationABB i-bus EIB Universal dimmer 6155 EB for Installation
73-1 - 5975 23459 ABB i-bus EIB Universal dimmer 6155 EB - 101-500 for Installation Operating instructions only for authorized, skilled electricians with EIB training Important instructions Attention It
More informationLED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series
Driver LC 200W 1050mA UNV ADV IND ADVANCED series Product description Independent constant current LED Driver For dry, damp and wet locations Max. output power 200 W Up to 93.7 % efficiency For luminaires
More informationBluetooth Tester CBT. Specifications. Specifications. Version January 2006
Specifications Version 03.00 Bluetooth Tester CBT January 2006 Specifications CONTENTS UNIT SPECIFICATIONS...3 TIMEBASE TCXO...3 REFERENCE FREQUENCY INPUT...3 RF GENERATOR...3 RF ANALYZER...5 Power meter
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationDFLK-D37 SUB/S. Extract from the online catalog. Order No.:
Extract from the online catalog DFLK-D37 SUB/S Order No.: 2280336 The illustration shows version DFLK-D37 SUB/B VARIOFACE panel feed-through module, for direct coupling of single signal lines of up to
More informationThere is a button to select either the AES/EBU or S/PDIF input for the D/A converter, which is located on the rear panel.
4 RB-DAC1 Digital to Analogue Converter Introduction Fig 4-1: RB-DAC1 Front Panel Using 24 bit, 96kHz capable devices, the RB-DAC1 Digital to Analogue Converter is a 1U rack-mount which produces a stereo
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More information16 A and 25 A power contactors with or without handle
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 16 and 25 power contactors CONTENTS PGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning -
More informationLED Driver Compact dimming
Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250
More informationPRINCIPLES AND APPLICATIONS
GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationDigital output modules
Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note - - - - Features 8 outputs, in groups
More informationI r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100
Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval
More informationR&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards
Broadcasting Data Sheet 02.01 R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards R&S SLx8000 Family of UHF/VHF Transmitters At a glance The UHF/VHF
More informationFigure 1: Device components
Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe
More informationCapacitors and banks 50 Hz 0 400/415 V network voltage
Capacitors and anks 50 Hz 0 Varplus M capacitors 051327 E92427 E92428 E89596 E89598 The range of Varplus M modular capacitors consists of the Varplus M1 and Varplus M4 capacitors, whose different assemly
More informationDATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.
Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features
More informationThe Art of Engineering
The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet
More informationProduct Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents
Product Brochure Version 01.00 200 A Four-Line V-Network RFI voltage measurements at high currents ENV4200_bro_en_5214-8390-12_v0100.indd 1 26.01.2017 15:22:54 200 A Four-Line V-Network At a glance The
More informationI Ex-protected connectors exlink I
Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationIP Roombox. Hotel Room Management
Hotel Room Management Hotel solutions Versatile room management system You need a simple solution which allows you to control all the hotel room electrical applications? Hager offers you a unique combination
More informationI r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release
More informationModular Power System acc. VG MoFess Module for Military Ground Vehicles
This new modular Power System for Military Ground Vehicles based on a standard box incorporating up to three different power modules. The power inlet module (230 V AC) includes line filter, lightning protection
More informationMultifunction Digital Timer
Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More informationMKH 8060 Directional studio microphone
MKH 8060 Directional studio microphone Instruction manual Contents Contents Important safety information... 2 The MKH 8060... 3 Delivery includes... 4 Product overview... 5 Putting the MKH 8060 into operation...
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationOT 100/ /700 P5
OT 100/120 277/700 P5 OPTOTRONIC Outdoor Constant current LED drivers Areas of application _ Street and urban lighting _ Industry _ Suitable for luminaires of protection class I Product benefits _ High
More informationProtection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type
More informationSurge Protective Device
Surge Protective Device Series RE - Residential TYPE Whole house surge protection Blue indicator LED 50 ka surge current strength Optional electrical noise filter Five year warranty Protect residence from
More informationDVO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen September 24, 2002 1(5) FIBRE OPTIC TRANSMITTER is a high performance, extremely linear externally modulated 1550 nm transmitter for DVO fibre optic CATV link. This transmitter type has been
More informationProduct range. Safety technique. Monitoring technique. Power electronics. Control technique. Time control technique. Installation technique
echnique de Installation technique sécurité Product range Safety technique Safety switching devices Standstill / speed monitoring Multifunctional safety devices Wireless Safety System Safety switches
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More information18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V
18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V With its characteristics of power stability whatever the load, very fast response time when pulsed (via external modulated signal), low ripple,
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationSINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS
SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical
More informationAC diagonal module Ø 200 mm
max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More information