Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

Size: px
Start display at page:

Download "Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance"

Transcription

1 177 PHOTO PHOTO Digital Sensor SERIES Related Information General terms and conditions... F-17 SC-GU P.935~ General precautions... P.145 Sensor selection guide P.3~ Glossary of terms... P.1359~ Korea s S-mark... P.141 Conforming to EMC Directive Certified NPN output types of connector type only Recognition * Passed the U 991 Environment Test * U 611C-1 compatible, Passed the U 991 Environment Test based on SEMI S2-2. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: U 611C-1] [Additional test / evaluation standards as per intended use: U 991, SEMI S2-2] PNP output type available Timer Interference prevention ight intensity monitor MEASURE panasonic-electric-works.net/sunx Constant advances achieving significant improvement of sensing performance Automatic sensitivity setting The digital fiber sensor FX-31(P) has been modified since its production in June 24. Stable sensing over long and short periods FX-31 FX-31-HS FX-35 Even greater sensing range All models In addition to a four-chemical emitting element which suppresses changes in the light emitting element over time so that a stable level of light emission can be maintained over long periods, a APC (Auto Power Control) circuit has also been adopted afreshly. The light emitting amount can be controlled in minute degrees so that even changes occurring over very short periods can be handled, allowing stable sensing performance by suppressing deviations in light emitting amounts caused by changes in the ambient environment that could not previously be suppressed. Adoption of a double coupling lens that increases emission efficiency to its maximum limits and greatly increases sensing range. Sensing ranges with small diameter fibers and ultra-small diameter fibers, which have become very popular due to the miniaturization of chip components, have been increased by 5 % over previous values achieved with other amplifiers. Conventional fiber sensors (Without lens) Stable sensing comparison ight emitting amount Short-term stability Deviation ong-term stability Time FX-31 FX-31-HS FX-35 Three-chemical emitting element, Without APC Double coupling lens Disperses the light reduces emitting efficiency. The lens concentrates the light, greatly increasing emitting efficiency.

2 Digital Sensor SERIES 178 APPICATIONS Detecting the presence or absence of labels The light-emitting amount selection function can even stabilize detection of transparent labels that saturate the light-receiving level. Detecting the presence or absence of ICs on a tray You can set upper and lower limits for the threshold values using the window comparator mode and turn ON / OFF the incident light intensity within that limit. Detecting the passage of small objects The differential sensing mode will only detect rapid changes in the amount of light, which makes it possible for small objects to be detected. PHOTO PHOTO ight-emitting amount selection FX-31 FX-31-HS FX-35 If the light receiving level becomes saturated during close-range sensing or when sensing transparent or minute objects, you can adjust the light emitting amount of the sensor to stabilize sensing without needing to change the response time. Sensing that previously required the response time or fibers to be changed can now be set much more easily using this function. arge display 9999 FX-35 arge display with 4 digits (9999). With a greater difference in digit value than previous models, threshold values can be set in units of 1 digit up to maximum Threshold setting can now be done more easily and accurately. (During, ONG and U-G modes) Digit difference: Small 2.5 times previous models Previous models 4 [ight receiving level saturated] Digit difference comparison Example Digit difference between object A and object B A 4 B Digit difference: arge Actual digit difference: C Upper display limit Saturated digit difference: D FX ight emitting amount changed [Stable sensing] A, B, Actual digit difference: C Ultra high-speed 35 µs response FX-31-HS Ultra high-speed 35 µs response. Even small objects moving at high speeds can be sensed. In addition, at 65 µs the FX-31 standard type and FX-35 highfunction type is also twice as fast as previous models. evel 4 evel 3 evel 2 evel 1 OFF ight emitting amount can be changed without changing response time Ultra high-speed type FX-31-HS (H-SP mode) 35 μs Standard type FX-31, High-function type FX-35 (H-SP mode) 65 μs Previous model 15 μs 4 times as fast as before 35 µs MEASURE

3 179 Digital Sensor SERIES PHOTO PHOTO Simplified systems using new operating modes A window comparator mode and differential sensing mode have been added. These modes make it easy to carry out sensing tasks that previously required multiple sensors or involved complex threshold settings. Window comparator mode <Sensing ICs in trays> Differential sensing mode <Sensing of tiny moving objects> FX-35 MEASURE Equipped with 5 types timers Tray absent IC present Tray present OFF ON OFF Incident light intensity Upper and lower limits for threshold values can be set so that the incident light intensity can turn on and off within those ranges. Single output is used, so that only one cable is required, and no PC processing is required either. The FX-35 includes the same ON-delay / OFF-delay / ONE SHOT timer as the FX-31(-HS), as well as an ON-delay OFF-delay timer and an ON-delay ONE SHOT timer. A wide variety of timer control operations can be carried out by these fiber sensors alone. Timer period Output 1:.5 to 9,999 ms (variable) Output 2:.5 to 5 ms (variable) Incident light intensity ON-delay ower light amounts due to dust Because sensing is not possible at normal sensitivity settings, sensitivity must be reset. ON ON Sensing of only sudden changes in light amounts Only the target objects are sensed. No need to reset the sensitivity. Time chart Sensing condition OFF-delay ONE SHOT ON-delay OFF-delay ON-delay ONE SHOT T1 For -ON T1 T1 T1 T1 T1 T2 T2 T1 FX-35 Beamreceived Beaminterrupted ON OFF ON OFF ON OFF ON OFF ON OFF Even beginners can quickly learn how to use the MODE NAVI MODE NAVI uses six indicators to display the amplifier s basic operations. The current operating mode can be confirmed at a glance, so even a first time user can easily operate the amplifier without becoming confused. RUN TEACH ADJ RUN TEACH ADJ RUN TEACH ADJ RUN This is the sensing mode. Incident light level is displayed in the digital display. TEACH This mode is for setting the threshold value. ADJ In this mode, the threshold value, once set, may be fine-tuned. All models /D / D ON TIMER This mode allows the selection of output operation as either PRO ight-on or Dark-ON. /D TIMER TIMER This mode permits the choice of using or not PRO using the timer. /D PRO TIMER This mode allows the selection of further advanced functions, such as the copying of PRO individual settings and the memory functions. Easy confirming of threshold value settings FX-31 FX-31-HS FX-35 The threshold value can be confirmed by turning the jog switch even during RUN mode. Jog switch is turned eft: FX-31(-HS) Output 1 for FX-35 Right: Output 2 for FX-35 The threshold value is displayed

4 Digital Sensor SERIES 18 The use of only two switches makes for very simple operations Only two switches, the large jog switch and the large MODE key, are required for operation. You can operate it simply by the 3 steps shown on the right. arge MODE key Pressing the switch selects or cancels the operating mode A quick-connection cable saves wiring and work-hours Connector type One unit can be used as either a main unit or sub unit The amplifier unit can be used as either a main unit or a sub unit. This feature allows for easy mounting in the side-by-side configuration. The main and sub unit functions are distinguished only by the proper use of the main cable and the sub cable. Moreover, inventory management and maintenance is simplified. FX-35 FX-31(-HS) FX-31B/G/H Main cable (4-core) CN-74-C Sub cable (2-core) CN-72-C Main cable (3-core) CN-73-C Sub cable (1-core) CN-71-C 1 Identical part numbers eliminate the need for costly inventory management labor Main cable Sub cable arge jog switch 2 3 Moving the switch from side to side allows items to be selected All models Pressing the switch then confirms the selected setting An optical communication function allows up to *16 sensors to be adjusted simultaneously FX-31 FX-35 The optical communication function allows the data that is currently set to be copied and saved all at once for all amplifiers connected together from the right side. This greatly reduces troublesome setup tasks and makes setup much smoother.in addition, troublesome adjustment operations at times such as when replacing sensors can also be carried out easily and data can also be copied and stored Single copy & save operation for all amplifiers using the optical communication function. * Use the optical communication function for only the same types of sensors. Furthermore, the FX-31-HS is not equipped with optical communication function capability. Settings can be entered directly using numerical input All models Every function can be directly set merely by the input of a four digit code (numbers) from the code table. This convenient feature is easy to set up. In the event that settings are accidentally changed at the operating site, merely entering the correct code can restore the original settings. This results in easy and quick maintenance. Communication unit improves equipment starting up and maintenance External input unit for digital sensor FX-CH2 Teaching and changing settings can be performed by using the PC and touch panel. Various settings and switching of up to 16 units of digital fiber sensors can be accomplished at once without operating the actual sensors themselves, but via external signals, such as the PC, touch panel, and push buttons. <Main functions> Batch teaching Key lock setting Batch loading / saving of the data bank Upper communication unit for digital sensor First digit: Settings for response time and hysteresis Second digit: Settings for /D ON and display mode Fourth digit: Timer period settings Third digit: Settings for Adjust lock and timer SC-GU1-485 We now offer remote maintenance for digital sensors! The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching) to be carried out via a PC or a personal computer, and also allows confirming of the incident light intensity an output status for the fiber sensors. This greatly improves workability during equipment starting up and maintenance. <Communicable commands> Sensor incident light intensity Sensor settings verification Sensor output status Threshold value settings, etc. FX-31 FX-35 FX-31(P) FX-35(P) PHOTO PHOTO MEASURE PC Refer to our website for details Compatible with all PCs equipped with RS-485 compatible units Refer to SC-GU1-485 pages for details RS-485 SC-GU1-485 communication

5 181 Digital Sensor SERIES ORDER GUIDE Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Appearance Model No. Emitting element Output Standard type High-speed type FX-31 FX-31P FX-31B FX-31BP FX-31G FX-31GP FX-31H FX-31HP FX-31-HS FX-31P-HS Red ED Blue ED Green ED Infrared ED Red ED NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor Quick-connection cables Type Model No. ength CN-73-C1 1 m ft Sub cable (1-core) Main cable (3-core) CN-73-C2 2 m ft CN-73-C5 5 m ft CN-71-C1 1 m ft CN-71-C2 2 m ft CN-71-C5 5 m ft High-function type FX-35 FX-35P Red ED NPN open-collector transistor PNP open-collector transistor Main cable (4-core) Sub cable (2-core) CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5 1 m ft 2 m ft 5 m ft 1 m ft 2 m ft 5 m ft

6 Digital Sensor SERIES 182 ORDER GUIDE Quick-connection cables For FX-31(-HS)/B/G/H Quick-connection cable is not supplied with the amplifier. Please order it separately. Main cable Type Model No. Description CN-73-C Main cable (3-core) Sub cable (1-core) CN-73-C1 CN-73-C2 CN-73-C5 CN-71-C1 CN-71-C2 CN-71-C5 ength: 1 m ft ength: 2 m ft ength: 5 m ft ength: 1 m ft ength: 2 m ft ength: 5 m ft.15 mm 2 3-core cabtyre cable, with connector on one end Cable outer diameter: ø3. mm ø.118 in.15 mm 2 1-core cabtyre cable, with connector on one end Cable outer diameter: ø3. mm ø.118 in Sub cable CN-71-C For FX-35 Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Model No. Description Main cable (4-core) Sub cable (2-core) CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5 ength: 1 m ft ength: 2 m ft ength: 5 m ft ength: 1 m ft ength: 2 m ft ength: 5 m ft.15 mm 2 4-core cabtyre cable, with connector on one end Cable outer diameter: ø3. mm ø.118 in.15 mm 2 2-core cabtyre cable, with connector on one end Cable outer diameter: ø3. mm ø.118 in Main cable CN-74-C Sub cable CN-72-C End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade. Appearance Model No. Description MS-DIN-E When cascading multiple amplifiers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp amplifiers into place on both sides. Make sure to use end plates when cascading multiple amplifiers together. Two pcs. per set Designation Model No. Description Amplifier mounting bracket amplifier protection seal MS-DIN-2 FX-MB1 Mounting bracket for amplifier 1 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another amplifier, as well as, prevents effect on another amplifier. Connector seal: It prevents contact of any metal, etc., with the pins of the quickconnection cable. Note: amplifier protection seals are supplied with the FX-31(P) and FX-35(P). Amplifier mounting bracket MS-DIN-2 amplifier protection seal FX-MB1 Communication window seal Connector seal

7 183 Digital Sensor SERIES IST OF S FX-31 / FX-35 (Red ED type) sensing range (Note 1) Thru-beam type (one pair set) are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. The FX-35 and FX-31(-HS) have different sensing modes. FX-35: H-SP, ST,,, ONG, U-G (no S-D mode) FX-31(-HS): S-D, H-SP (Note 1), ST,, ONG (no or U-G mode) Sensing range (mm in) (Note 2) Red ED U-G ONG ST H-SP S-D Dimensions FT P.9 FT P.9 FT-4 1, P.9 FT-41 1, P.9 FT-42 1, P.9 FT-A8 3, (Note 3) 3, (Note 3) 3, , , , P.9 FT-A3 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, , (Note 3) P.9 FT-AFM P.9 FT-AFM2E P.9 FT-B8 1, , P.9 FT-E P.91 FT-E P.91 FT-E P.91 FT-E P.91 FT-FM2 1, P.91 FT-FM2S 1, P.91 FT-FM2S4 1, P.91 FT-FM1 19, (Note 4) 19, (Note 4) 19, (Note 4) 14, , , , P.91 FT-H13-FM2 1, P.91 FT-H2-J2-S (Note 5) P.92 FT-H2-J3-S (Note 5) P.92 FT-H2-J5-S (Note 5) P.92 FT-H2-M P.92 FT-H2-VJ5-S (Note 5) P.92 FT-H2-VJ8-S (Note 5) P.92 FT-H2W-M P.92 FT-H3-M1V-S (Note 6) P.92 FT-H35-M P.92 FT-H35-M2S P.92 FT-H8Y 3, (Note 3) 3, (Note 3) 1, , P.92 FT-K8 3, , , , P.93 FT-KV P.93 FT-KV8 3, , , , P.93 FT-8Y 3, , , , , P.93 FT-NFM P.93 FT-NFM2S P.93 FT-NFM2S P.93 FT-P P.93 FT-P P.93 FT-P P.93 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-31-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 3) The fiber cable length practically limits the sensing range to 3,5 mm in long. 4) The fiber cable length practically limits the sensing range to 19,5 mm in long. 5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. 6) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).

8 Digital Sensor SERIES 184 IST OF S FX-31 / FX-35 (Red ED type) sensing range (Note 1) Thru-beam type (one pair set) are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. The FX-35 and FX-31(-HS) have different sensing modes. FX-35: H-SP, ST,,, ONG, U-G (no S-D mode) FX-31(-HS): S-D, H-SP (Note 1), ST,, ONG (no or U-G mode) Sensing range (mm in) (Note 2) Red ED U-G ONG ST H-SP S-D Dimensions FT-P P.93 FT-P81X P.94 FT-PS P.93 FT-R P.94 FT-S P.94 FT-S P.94 FT-S3 1, P.94 FT-SFM2 1, P.94 FT-SFM2 2, , P.94 FT-SFM2SV P.94 FT-SNFM P.95 FT-T8 1, P.95 FT-V1 2, , , , P.95 FT-V P.95 FT-V P.95 FT-V8Y 1, P.95 FT-W P.95 FT-W P.95 FT-WA8 3, (Note 3) 3, (Note 3) 3, , , , P.95 FT-WA3 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, (Note 3) 3, , (Note 3) P.95 FT-WKV8 2, , , P.96 FT-WR P.96 FT-WR8 1, , P.96 FT-WS P.96 FT-WS P.96 FT-WS P.96 FT-WS8 1, , P.96 FT-WV P.96 FT-WZ P.96 FT-WZ4HB P.97 FT-WZ P.97 FT-WZ7HB P.97 FT-WZ P.97 FT-WZ8E 2, , P.97 FT-WZ8H 3, , , , P.97 FT-Z8 1, P.97 FT-Z8E 1, , P.97 FT-Z8H 3, , , , , P.97 FT-Z82Y 3, , , , , P.97 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-31-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 3) The fiber cable length practically limits the sensing range to 3,5 mm in long.

9 185 Digital Sensor SERIES IST OF S FX-31 / FX-35 (Red ED type) sensing range (Note 1) Retroreflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. The FX-35 and FX-31(-HS) have different sensing modes. FX-35: H-SP, ST,,, ONG, U-G (no S-D mode) FX-31(-HS): S-D, H-SP (Note 1), ST,, ONG (no or U-G mode) Sensing range (mm in) (Note 2, 3) Red ED U-G ONG ST H-SP S-D Dimensions FR-KV1 15 to to to to to to to to to to to to to to P.98 FR-KZ21 2 to to to to to to to to to to to to to to P.98 FR-KZ21E 2 to to to to to to to to to to to to to to P.98 FR-WKZ11 1 to to to to to to to to to to P.98 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-31-HS in H-SP mode. 2) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21 and FR-KZ21E is specified for the attached reflector RF-3. The sensing range of FR-KV1 is specified for the attached reflector. 3) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber, reflected incident light may affect the fiber. If this occurs, adjust the threshold value of the amplifier unit before use. FX-31 / FX-35 (Red ED type) sensing range (Note 1) Reflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. The FX-35 and FX-31(-HS) have different sensing modes. FX-35: H-SP, ST,,, ONG, U-G (no S-D mode) FX-31(-HS): S-D, H-SP (Note 1), ST,, ONG (no or U-G mode) Sensing range (mm in) (Note 2, 3) Model No. Red ED Dimensions U-G ONG ST H-SP S-D FD P.99 FD P.99 FD P.99 FD P.99 FD P.99 FD P.99 FD-A P.99 FD-AFM P.99 FD-AFM2E P.99 FD-B P.99 FD-E P.1 FD-E P.1 FD-EG P.1 FD-EG P.1 FD-EG P.1 FD-EN5S Cannot use Cannot use P.1 FD-ENM1S P.1 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø.236 to ø1.24 in transparent pipe FD-F4 [P (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm.39 in] P.1 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø.236 to ø1.24 in transparent pipe FD-F41 [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm.39 to.118 in] P.1 ø4 mm ø.157 in form Protective tube: fluorine resin, length 5 mm in (cuttable) FD-F41Y iquid surface not contacted: Beam received, iquid surface contacted: Beam interrupted P.11 FD-F8Y P.11 Applicable pipe diameter: Outer dia. ø8 mm ø.315 in or more transparent pipe (When used with the tying bands: ø8 to ø8 mm ø.315 to ø3.15 in) [P (fluorine resin), including translucent] FD-9 iquid absent: Beam received, iquid present: Beam interrupted P.11 FD-FM P.11 FD-FM2S P.11 FD-FM2S P.11 FD-G P.11 FD-G P.12 FD-G6X P.12 FD-G P.11 FD-G P.12 FD-H13-FM P.12 FD-H18-31 to 2 to.787 to 15 to.591 to 1 to.394 to 1 to to 8.39 to.315 Cannot use 2 to 6.79 to.236 P.12 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-31-HS in H-SP mode. 2) The standard sensing objects of the sensing ranges vary depending on the fibers. 3) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut.

10 Digital Sensor SERIES 186 IST OF S FX-31 / FX-35 (Red ED type) sensing range (Note 1) Reflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. Sensing range (mm in) (Note 2, 3) Red ED U-G ONG ST H-SP S-D Dimensions FD-H P.12 FD-H2-M P.12 FD-H to to to to to to.96 4 to to to to to to.63 4 to to.63 P.13 FD-H to to to to to to to to P.13 FD-H3-KZ1V-S (Note 4) 2 to to to to to to to to to to Cannot use Cannot use P.13 FD-H3-32 to 2 to.787 to 15 to.591 to 1 to.394 to 1 to to 8.39 to.315 Cannot use 2 to 6.79 to.236 P.13 FD-H3-32V-S (Note 4) to 11 to.433 to 8 to to 6.59 to to 5.59 to to 4.79 to.157 Cannot use Cannot use P.13 FD-H35-2S P.14 FD-H35-M P.14 FD-H35-M2S P.14 ø4 mm ø.157 in form Protective tube: fluorine resin, length:5 mm in (allowable cutting) FD-HF4Y iquid surface not contacted: Beam received, iquid surface contacted: Beam interrupted P.14 FD-4 FD-41 2 to 2.79 to.787 (Convergent point 6.236) 2.5 to to.79 (Convergent point 6.236) 4 to to.472 (Convergent point 6.236) 4 to to.472 (Convergent point 6.236) 4.5 to to.433 (Convergent point 6.236) 5 to to.335 (Convergent point 6.236) 4.8 to to.374 (Convergent point 6.236) 2 to to to to.79 3 to to.63 3 to to to to.591 (Convergent point 8.315) (Convergent point 8.315) (Convergent point 8.315) (Convergent point 8.315) (Convergent point 8.315) Cannot use Cannot use P.14 FD-43 to 23 to.96 P.14 FD-44 to 8.2 to.323 to 7 to.276 to 6.5 to.256 to 6 to.236 to 5.7 to.224 to 5 to.197 to 5.2 to.25 P.14 FD-44S to 4.7 to.185 to 4.5 to.177 to 4 to.157 to 4 to.157 to 3.8 to.15 to 3 to.118 to 3.5 to.138 P.14 FD-45 to 5 to to 36 to to 33 to to 3 to to 3 to to 15 to.591 to 21 to.827 P.14 FD-45A 1 to to (Note 5) 1 to to (Note 5) 1 to to 1.26 (Note 5) 1 to to 1.26 (Note 5) 1 to to 1.26 (Note 5) 13 to to.79 (Note 5) 13 to to.79 (Note 5) FD to to to to to to to to to to Cannot use Cannot use P.15 FD to to to to to to 1.63 P.15 FD-NFM P.15 FD-NFM2S P.15 FD-NFM2S P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P81X P.16 FD-R P.16 FD-S P.16 FD-S P.16 FD-S P.16 FD-SFM2SV P.16 FD-SNFM P.16 FD-T P.16 FD-T P.16 FD-V P.16 FD-W P.17 FD-W P.17 FD-WG P.17 FD-WKZ1 2 to to to to to to to to to to to to to to P.17 FD-W to to.571 (Convergent point 8.315) 6.5 to to.551 (Convergent point 8.315) 7 to to.551 (Convergent point 8.315) The FX-35 and FX-31(-HS) have different sensing modes. FX-35: H-SP, ST,,, ONG, U-G (no S-D mode) FX-31(-HS): S-D, H-SP (Note 1), ST,, ONG (no or U-G mode) 7 to to.472 (Convergent point 8.315) P.14 P to to.472 (Convergent point 8.315) Cannot use Cannot use P.17 FD-W48.5 to to to to to to to to to 5.39 to.197 Cannot use Cannot use P.17 FD-WS P.17 FD-WSG P.17 FD-WT P.17 FD-WT P.17 FD-WV Cannot use Cannot use P.18 FD-WZ4 1 to 5.39 to to to to to to to to to.394 P.18 FD-WZ4HB 1 to 7.39 to to to to to to to to to to to to to.276 P.18 FD-WZ to to to 6.39 to to to to to to to.79 P.18 FD-WZ7HB.5 to 27.2 to to 18.2 to to to to 9.39 to to 7.39 to to to to to P.18 Notes: 1) Refer to p.35~ for the sensing ranges for the FX-31-HS in H-SP mode. 2) The standard sensing objects of the sensing ranges vary depending on the fibers. 3) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 5) Sensing distance varies depending on the sensing object s inclination.

11 187 Digital Sensor SERIES SENSING RANGE OF BUE ED / GREEN ED / INFRARED ED Thru-beam type (One pair set) are listed in alphabetic order. Refer to p.5~ for details of each fiber. Sensing range (mm in) (Note 1) Model No. FX-31B FX-31G FX-31H (Note 2) Dimensions ONG ST ONG ST ONG ST FT P.9 FT P.9 FT P.9 FT P.9 FT P.9 FT-A P.9 FT-A3 2, , , P.9 FT-AFM P.9 FT-AFM2E P.9 FT-B P.9 FT-E P.91 FT-E P.91 FT-E P.91 FT-E P.91 FT-FM P.91 FT-FM2S P.91 FT-FM2S P.91 FT-FM1 5, , , , , , , (Note 3) 1, (Note 3) (Note 3) P.91 FT-H13-FM P.91 FT-H2-J2-S (Note 4) P.92 FT-H2-J3-S (Note 4) P.92 FT-H2-J5-S (Note 4) P.92 FT-H2-M P.92 FT-H2-VJ5-S (Note 4) P.92 FT-H2-VJ8-S (Note 4) P.92 FT-H2W-M P.92 FT-H3-M1V-S (Note 5) P.92 FT-H35-M P.92 FT-H35-M2S P.92 FT-H8Y , P.92 FT-K P.93 FT-KV P.93 FT-KV P.93 FT-8Y P.93 FT-NFM P.93 FT-NFM2S P.93 FT-NFM2S P.93 FT-P P.93 FT-P P.93 FT-P P.93 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with varying humidity. 3) Sensing range when fiber length is 2 m ft. When fiber length is 1 m ft, the beam attenuates and cannot be used. 4) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. 5) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).

12 Digital Sensor SERIES 188 SENSING RANGE OF BUE ED / GREEN ED / INFRARED ED Thru-beam type (One pair set) are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. Sensing range (mm in) (Note 1) FX-31B FX-31G FX-31H (Note 2) ONG ST ONG ST ONG ST FT-P P.93 FT-P81X P.94 FT-PS P.93 FT-R P.94 FT-S P.94 FT-S P.94 FT-S P.94 FT-SFM P.94 FT-SFM P.94 FT-SFM2SV P.94 FT-SNFM P.95 FT-T P.95 FT-V P.95 FT-V P.95 FT-V P.95 FT-V8Y P.95 FT-W P.95 FT-W P.95 FT-WA P.95 FT-WA3 2, , , P.95 FT-WKV P.96 FT-WR P.96 FT-WR P.96 FT-WS P.96 FT-WS P.96 FT-WS P.96 FT-WS P.96 FT-WV42 P.96 FT-WZ P.96 FT-WZ4HB P.97 FT-WZ P.97 FT-WZ7HB P.97 FT-WZ P.97 FT-WZ8E P.97 FT-WZ8H P.97 FT-Z P.97 FT-Z8E P.97 FT-Z8H P.97 Dimensions FT-Z82Y P.97 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 2) Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an environment with varying humidity.

13 189 Digital Sensor SERIES SENSING RANGE OF BUE ED / GREEN ED / INFRARED ED Retroreflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. Sensing range (mm in) (Note 1, 2) Model No. FX-31B FX-31G FX-31H Dimensions ONG ST ONG ST ONG ST FR-KV1 P.98 FR-KZ21 2 to to to to to to to to to to to to to to to to P.98 FR-KZ21E 2 to to to to to to to to to to P.98 FR-WKZ11 1 to to P.98 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber, reflected incident light may affect the fiber. If this occurs, adjust the threshold value of the amplifier unit before use. Reflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. Sensing range (mm in) (Note 1, 2) FX-31B FX-31G FX-31H Dimensions ONG ST ONG ST ONG ST FD P.99 FD P.99 FD P.99 FD P.99 FD P.99 FD P.99 FD-A P.99 FD-AFM P.99 FD-AFM2E P.99 FD-B P.99 FD-E P.1 FD-E P.1 FD-EG P.1 FD-EG P.1 FD-EG P.1 FD-EN5S1 P.1 FD-ENM1S P.1 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø.236 to ø1.24 in transparent pipe FD-F4 [P (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm.39 in] P.1 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø.236 to ø1.24 in transparent pipe FD-F41 [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm.39 to.118 in] P.1 ø4 mm ø.157 in form Protective tube: fluorine resin, length 5 mm in (cuttable) FD-F41Y iquid surface not contacted: Beam received, iquid surface contacted: Beam interrupted P.11 FD-F8Y P.11 Applicable pipe diameter: Outer dia. ø8 mm ø.315 in or more transparent pipe (When used with the tying bands: ø8 to ø8 mm ø.315 to ø3.15 in) [P (fluorine resin), including translucent] FD-9 iquid absent: Beam received, iquid present: Beam interrupted P.11 FD-FM P.11 FD-FM2S P.11 FD-FM2S P.11 FD-G P.11 FD-G P.12 FD-G6X P.12 FD-G P.11 FD-G P.12 FD-H13-FM P.12 FD-H18-31 P.12 FD-H P.12 FD-H2-M P.12 Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut.

14 Digital Sensor SERIES 19 SENSING RANGE OF BUE ED / GREEN ED / INFRARED ED Reflective type are listed in alphabetic order. Refer to p.5~ for details of each fiber. Model No. Sensing range (mm in) (Note 1, 2) FX-31B FX-31G FX-31H ONG ST ONG ST ONG ST Dimensions FD-H25-43 P.13 FD-H25-45 P.13 FD-H3-KZ1V-S (Note 3) 3 to to P.13 FD-H3-32 P.13 FD-H3-32V-S (Note 3) P.13 FD-H35-2S P.14 FD-H35-M P.14 FD-H35-M2S P.14 ø4 mm ø.157 in form Protective tube: fluorine resin, length:5 mm in (allowable cutting) FD-HF4Y P.14 iquid surface not contacted: Beam received, iquid surface contacted: Beam interrupted 4.5 to to to to to to to to to to.315 FD to to.374 P.14 (Convergent point 6.236) (Convergent point 6.236) (Convergent point 6.236) (Convergent point 6.236) (Convergent point 6.236) (Convergent point 6.236) FD-41 P.14 FD-43 P.14 FD-44 to 5.7 to to to to to.15 1 to to to 3.98 to to to.169 P.14 FD-44S to 3.5 to to 3.39 to to 3.39 to to to.169 P.14 FD-45 P.14 FD-45A P.15 FD-46 P.15 FD-47 P.15 FD-NFM P.15 FD-NFM2S P.15 FD-NFM2S P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P P.15 FD-P81X P.16 FD-R P.16 FD-S P.16 FD-S P.16 FD-S P.16 FD-SFM2SV P.16 FD-SNFM P.16 FD-T P.16 FD-T P.16 FD-V P.16 FD-W P.17 FD-W P.17 FD-WG P.17 FD-WKZ1 P.17 FD-W41 P.17 FD-W48.5 to to.138 P.17 FD-WS P.17 FD-WSG P.17 FD-WT P.17 FD-WT P.17 FD-WV42 P.18 FD-WZ4 5 to to.315 P.18 FD-WZ4HB 4 to to to to.472 P.18 FD-WZ7 4 to to to to.315 P.18 FD-WZ7HB 3 to to to to to to to to.63 4 to to to to.79 P.18 Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 2 % max. depending upon how the fiber is cut. 3) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).

15 191 Digital Sensor SERIES ens (for thru-beam type fiber) For thru-beam type fiber Designation Model No. Description Expansion lens (Note 1) Superexpansion lens (Note 1) Side-view lens Expansion lens for vacuum fiber (Note 1) Vacuum resistant side-view lens (Note 1) FX-E1 FX-E2 FX-SV1 FV-E1 FV-SV2 Increases the sensing range by 5 times or more. Ambient temperature: 6 to +35 C 76 to +662 F (Note 5) Tremendously increases the sensing range with large diameter lenses. Ambient temperature: 6 to +35 C 76 to +662 F (Note 5) Beam axis is bent by 9. Ambient temperature: 6 to +3 C 76 to +572 F (Note 5) Sensing range increases by 4 times or more. Ambient temperature: 6 to +35 C 76 to +662 F (Note 5) Beam axis is bent by 9. Ambient temperature: 6 to +3 C 76 to +572 F (Note 5) Sensing range for red ED type (mm) [ens on both sides] (Note 3) Mode U-G ONG ST S-D H-SP FT-B8 3,5 (Note 2) 3,5 (Note 2) 3, 2,5 2, 1, 1, FT-FM2 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 2,5 1,3 1, FT-T8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 2,5 1,3 1, FT-R8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 2,3 1, FT-W8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 2,9 2, 1, 9 FT-P8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 2,5 1,1 1, FT-P6 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 1,5 9 8 FT-P81X 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,1 95 FT-H35-M2 3,5 (Note 2) 3,5 (Note 2) 2,5 2, 1, FT-H2W-M1 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1, FT-H2-M1 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,1 9 6 Sensing range for red ED type (mm) [ens on both sides] (Note 3) Mode U-G ONG ST S-D H-SP FT-B8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-FM2 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-R8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-W8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-P8 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-P6 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-P81X 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) FT-H35-M2 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) FT-H2W-M1 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,5 1,6 (Note 2) FT-H2-M1 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) 1,6 (Note 2) FT-H13-FM2 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) 3,5 (Note 2) Sensing range for red ED type (mm) [ens on both sides] (Note 3) Mode U-G ONG ST S-D H-SP FT-B8 1,45 1, FT-FM2 1,8 1, FT-T8 1,8 1, FT-W8 1, FT-P8 1,8 1, FT-P FT-P81X 1,8 1, FT-H35-M FT-H2W-M FT-H2-M Sensing range for red ED type (mm) [ens on both sides] (Note 3, 4) Mode U-G ONG ST S-D H-SP FT-H3-M1V-S 1,6 1, Sensing range for red ED type (mm) [ens on both sides] (Note 3, 4) Mode U-G ONG ST S-D H-SP FT-H3-M1V-S 1,6 1, Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have adjusted it sufficiently. 2) The fiber cable length practically limits the sensing range to 3,5 mm in long (FT-P81X, FT-H2W-M1 and FT-H2-M1: 1,6 mm in). 3) The sensing ranges are the values for red ED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers. 4) The fiber cable length for the FT-H3-M1V-S is 1 m ft. The sensing ranges in U-G and ONG modes take into account the length of the FT-J8 atmospheric side fiber. 5) Refer to p.76~ for the ambient temperatures of fibers to be used in combination.

16 Digital Sensor SERIES 192 ens (for reflective type fiber) For reflective type fiber Designation Model No. Description Pinpoint spot lens Zoom lens Finest spot lens Finest spot lens Zoom lens Side-view type FX-MR1 FX-MR2 FX-MR3 FX-MR6 FX-MR5 Screw-in depth Distance to focal point Distance to focal point Distance to focal point Spot diameter Screw-in depth Spot diameter Spot diameter Pinpoint spot of ø.5 mm ø.2 in. Enables detection of minute objects or small marks. Distance to focal point: 6 ±1 mm.236 ±.39 in Applicable fibers: FD-WG4, FD-G4 Ambient temperature: 4 to +7 C 4 to +158 F (Note 2) The spot diameter is adjustable from ø.7 to ø2 mm ø.28 to ø.79 in according to how much the fiber is screwed in. Applicable fibers: FD-WG4, FD-G4 Ambient temperature: 4 to +7 C 4 to +158 F (Note 2) Accessory: MS-EX-3 (mounting bracket) Extremely fine spot of ø.3 mm ø.12 in approx. achieved. Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 Ambient temperature: 4 to +7 C 4 to +158 F (Note 2) Extremely fine spot of ø.1 mm ø.4 in approx. achieved. Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 Ambient temperature: 2 to +6 C 4 to +14 F (Note 2) Sensing range for red ED type (Note 1) Screw-in depth Distance to focal point Spot diameter 7 mm.276 in ø18.5 mm ø.728 in approx. ø.7 mm ø.28 in 12 mm.472 in ø27 mm ø1.63 in approx. ø1.2 mm ø.47 in 14 mm.551 in ø43 mm ø1.693 in approx. ø2. mm ø.79 in Sensing range for red ED type (Note 1) Distance to focal point Spot diameter FD-EG3 7.5 ±.5 mm.295 ±.2 in ø.15 mm ø.6 in approx FD-EG2 7.5 ±.5 mm.295 ±.2 in ø.2 mm ø.8 in approx FD-EG1 7.5 ±.5 mm.295 ±.2 in ø.3 mm ø.12 in approx FD-WG4/G4/G6X/G6 7.5 ±.5 mm.295 ±.2 in ø.5 mm ø.2 in approx Sensing range for red ED type (Note 1) Distance to focal point Spot diameter FD-EG3 7 ±.5 mm.276 ±.2 in ø.1 mm ø.4 in approx FD-EG2 7 ±.5 mm.276 ±.2 in ø.15 mm ø.6 in approx FD-EG1 7 ±.5 mm.276 ±.2 in ø.2 mm ø.8 in approx FD-WG4/G4/G6X/G6 7 ±.5 mm.276 ±.2 in ø.4 mm ø.16 in approx FX-MR2 is converted into a Sensing range for red ED type (Note 1) side-view type and can be mounted in a very small space. Screw-in depth Distance to focal point Spot diameter Applicable fibers: FD-WG4, FD-G4 8 mm.315 in 13 mm.512 in approx. ø.5 mm ø.2 in Ambient temperature: 1 mm.394 in 15 mm.591 in approx. ø.8 mm ø.31 in 4 to +7 C 4 to +158 F (Note 2) 14 mm.551 in 3 mm in approx. ø3. mm ø.118 in Notes: 1) The sensing ranges are the values when used in combination with red ED type amplifier. Please contact our office for details on sensing ranges for other types of amplifier. 2) Refer p.76~ for the ambient temperatures of fibers to be used in combination. Others Protective tube bender Designation Model No. Description Protective tube (For thru-beam type fiber) Protective tube (For reflective type fiber) bender FB-1 FTP-5 (.5 m ft) FTP-1 (1 m ft) FTP-15 (1.5 m ft) FTP-N5 (.5 m ft) FTP-N1 (1 m ft) FTP-N15 (1.5 m ft) FDP-5 (.5 m ft) FDP-1 (1 m ft) FDP-15 (1.5 m ft) FDP-N5 (.5 m ft) FDP-N1 (1 m ft) FDP-N15 (1.5 m ft) Universal sensor MS-AJ1-F mounting stand (Note 2) MS-AJ2-F Single core FX-AT15A holder For M4 thread For M3 thread For M6 thread For M4 thread Applicable fibers FT-42 FT-B8 FT-FM2 FT-FM2S FT-31 FT-NFM2 FT-NFM2S FT-NFM2S4 FD-61 FD-B8 FD-FM2 FD-FM2S FT-FM2S4 FT-H13-FM2 FT-P6 FT-P8 FT-P4 FT-T8 FD-P4 FD-T4 FD-FM2S4 FD-H13-FM2 FD-P8 FD-41 FD-T8 FD-NFM2 FD-NFM2S FD-NFM2S4 The protective tube, made of noncorrosive stainless steel, protects the inner fiber cable from any external forces. The fiber bender bends the sleeve part of the fiber at the proper radius. (Note 1) Horizontal mounting type Mounting stand assembly for fiber Vertical mounting type (For M3,M4 or M6 threaded fiber) The incident light intensity may vary when using a multi-core fiber or a thin type sharp bending fiber. This holder suppresses the variation in the incident light intensity. Brown. Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter type fiber. 2) Refer to the universal sensor mounting stand MS-AJ series pages for details. FTP- FDP- Universal sensor mounting stand Using the arm which enables adjustment in the horizontal direction, sensing can also be done from above an assembly line. MS-AJ1-F Swivel: 36 rotation Forward / back adjustment: 13 mm in approx Angle adjustment: ±2 MS-AJ2-F Forward / back adjustment: 13 mm in approx Angle adjustment: ±2 Swivel: 36 rotation FB-1 Height adjustment: 15 mm 5.96 in approx. Mounting hole for M6 screw Single core holder FX-AT15A Height adjustment: 15 mm 5.96 in approx. Mounting hole for M6 screw

17 193 Digital Sensor SERIES SPECIFICATIONS Type Standard type High-speed Red ED Blue ED Green ED Infrared ED type High-function type NPN output FX-31 FX-31B FX-31G FX-31H FX-31-HS FX-35 Item PNP output FX-31P FX-31BP FX-31GP FX-31HP FX-31P-HS FX-35P Supply voltage 12 to 24 V DC ±1 % Ripple P-P 1 % or less Model No. Power consumption Output Output operation Short-circuit protection Response time Sensitivity setting <Red ED / Infrared ED type> Normal operation: 96 mw or less (Current consumption 4 ma or less at 24 V supply voltage) ECO mode: 6 mw or less (Current consumption 25 ma or less at 24 V supply voltage) <NPN output type> NPN open-collector transistor Maximum sink current:1 ma (5 ma, if five, or more, amplifiers are connected in cascade.) Applied voltage: 3 V DC or less (between output and V) Residual voltage: 1.5 V or less [at 1 ma (at 5 ma, if five, or more, amplifiers are connected in cascade) sink current.] <Blue ED / Green ED type> Normal operation: 72 mw or less (Current consumption 3 ma or less at 24 V supply voltage) ECO mode: 43 mw or less (Current consumption 18 ma or less at 24 V supply voltage) <NPN output type> NPN open-collector transistor 2 outputs Maximum sink current: 5 ma each (Note 2) Applied voltage: 3 V DC or less (between output and V) Residual voltage: 1.5 V or less [at 5 ma (Note 2)] <PNP output type> <PNP output type> PNP open-collector transistor PNP open-collector transistor 2 outputs Maximum source current: 1 ma (5 ma, if five, or more, amplifiers are connected in cascade.) Maximum source current: 5 ma each (Note 2) Applied voltage: 3 V DC or less (between output and +V) Applied voltage: 3 V DC or less (between output and +V) Residual voltage: 1.5 V or less [at 1 ma (at 5 ma, if five, or more, amplifiers are connected in cascade) source current.] Residual voltage: 1.5 V or less [at 5 ma (Note 2)] 65 µs or less [H-SP (Red ED type only)], 15 µs or less (ST), 25 µs or less [ / S-D (Red ED type only)], 2 ms or less (ONG), selectable with jog switch Selectable either ight-on or Dark-ON, with jog switch Incorporated 2-point teaching / imit teaching / Manual adjustment / Full-auto teaching / Max. sensitivity teaching 35 µs or less (H-SP), 15 µs or less (ST), 25 µs or less ( / S-D), 2 ms or less (ONG), selectable with jog switch 65 µs or less (H-SP), 15 µs or less (ST), 25 µs or less (), 7 µs or less (), 2.5 ms or less (ONG), 4.5 ms or less (U-G), selectable with jog switch Normal mode: 2-point teaching / imit teaching / Full-auto teaching / Max. sensitivity teaching / Manual adjustment Window comparator mode: Teaching (1-point / 2-point / 3-point) / Manual adjustment Operation indicator Orange ED (lights up when the output is ON) Stability indicator Green ED (lights up under stable light received condition or stable dark condition) MODE indicator RUN: Green ED, TEACH ADJ /D ON TIMER PRO: Yellow ED Digital display 4 digit red ED display Fine sensitivity adjustment function Incorporated Timer function ight emitting amount selection function Automatic interference prevention function Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. Timer period: Red ED type;.5 ms approx., 1 to 9999 ms (Blue ED, Green ED, Infrared ED type; approx..5 to 5 ms) Incorporated (Red ED type only) (Note 3) ST,, ONG: 4 level, H-SP: 3 level, S-D: 2 level Incorporated (Up to four sets of fiber s can be mounted close together. However, H-SP mode is 2 fiber s.) (Note 4) Incorporated (Note 3) ST,, ONG: 4 level H-SP, S-D: 2 level Incorporated with variable ON-delay / OFF-delay / ONE SHOT / ON-delay OFF-delay / ON-delay ONE SHOT timer, switchable either effective or ineffective. (Timer period: Output 1;.5 ms, 1 to 9999 ms, Output 2;.5 ms, 1 to 5 ms) Incorporated (Note 3) ST,,, ONG, U-G: 4 level H-SP: 3 level Incorporated [Up to four sets of fiber s can be mounted close together. (However, U-G mode is 8 fiber s, H-SP mode is 2 fiber s.)] (Note 5) Ambient temperature 1 to +55 C +14 to +131 F (If 4 to 7 units are connected in cascade: 1 to +5 C +14 to +122 F, if 8 to 16 units are connected in cascade: 1 to +45 C +14 to +113 F) (No dew condensation or icing allowed), Storage: 2 to +7 C 4 to +158 F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3, lx at the light-receiving face Voltage withstandability 1, V AC for one min. between all supply terminals connected together and enclosure (Note 6) Insulation resistance 2 MΩ, or more, with 25 V DC megger between all supply terminals connected together and enclosure (Note 6) Vibration resistance 1 to 15 Hz frequency,.75 mm.3 in amplitude in X, Y and Z directions for two hours each Shock resistance 98 m/s 2 acceleration (1 G approx.) in X, Y and Z directions for five times each Emitting element (modulated) Red ED Blue ED Green ED Infrared ED Red ED Red ED Peak emission wavelength 65 nm.26 mil 47 nm.19 mil 525 nm.21 mil 94 nm.37 mil 65 nm.26 mil 65 nm.26 mil Material Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-31B/G/H: Acrylic) Connecting method Connector (Note 7) Cable length Total length up to 1 m ft (5 m ft for 5 to 8 units, 2 m ft for 9 to 16 units) is possible with.3 mm 2, or more, cable. Weight Net weight: 2 g approx., Gross weight: 25 g approx. Accessory FX-MB1 (amplifier protection seal): 1 set FX-MB1 (amplifier protection seal): 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C F. 2) 5 ma per output. 25 ma if five, or more, amplifiers are connected in cascade. 3) The light emitting amount can be zero (emission halt) in all modes. 4) When the power supply is switched on, the light emission timing is automatically set for interference prevention. 5) When the interference prevention function is set, the number of mountable fiber s becomes double. Furthermore, take care that the response time also becomes double. 6) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. 7) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below. Main cable (3-core) for FX-31(P)(-HS): CN-73-C1 (Cable length 1 m ft), CN-73-C2 (Cable length 2 m ft), CN-73-C5 (Cable length 5 m ft) Sub cable (1-core) for FX-31(P)(-HS): CN-71-C1 (Cable length 1 m ft), CN-71-C2 (Cable length 2 m ft), CN-71-C5 (Cable length 5 m ft) Main cable (4-core) for FX-35(P): CN-74-C1 (Cable length 1 m ft), CN-74-C2 (Cable length 2 m ft), CN-74-C5 (Cable length 5 m ft) Sub cable (2-core) for FX-35(P): CN-72-C1 (Cable length 1 m ft), CN-72-C2 (Cable length 2 m ft), CN-72-C5 (Cable length 5 m ft) Environmental resistance

18 Digital Sensor SERIES 194 Sensor circuit I/O CIRCUIT AND WIRING DIAGRAMS FX-31(-HS) I/O circuit diagram Sensor circuit Tr Tr1 Tr2 D D ZD1 ZD Terminal No. Color code of quick-connection cable (Brown) +V (Note 1) 1 oad (Black) Output 3 1 ma max. (Note 2) (Blue) V (Note 1) 2 Terminal No. Color code of quick-connection cable (Brown) +V (Note 1) 1 5 ma max. (Note 2) 3 ZD2 (Black) Output 1 5 ma max. (Note 2) 4 (White) Output 2 oad 2 (Blue) V (Note 1) oad 12 to 24 V DC ±1 % Internal circuit Users circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and V (blue). The power is supplied from the connector of the main cable. 2) 25 ma max., if five amplifiers, or more, are connected together to 24 V DC ±1 % Internal circuit Users circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and V (blue). The power is supplied from the connector of the main cable. 2) 5 ma max., if five amplifiers, or more, are connected together. Symbols D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor FX-31P(-HS) I/O circuit diagram Sensor circuit Tr D ZD Terminal No. Color code of quick-connection cable (Brown) +V (Note 1) 1 1 ma max. (Note 2) 3 (Black) Output oad (Blue) V (Note 1) to 24 V DC ±1 % Internal circuit Users circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and V (blue). The power is supplied from the connector of the main cable. 2) 5 ma max., if five amplifiers, or more, are connected together. Symbols D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor FX-35 I/O circuit diagram Sensor circuit Terminal No. Color code of quick-connection cable D (Brown) +V (Note 1) 1 Tr1 (Black) Output oad 3 oad Tr2 ZD1 (White) Output 2 5 ma max. (Note 2) 4 ZD2 5 ma max. (Note 2) 2 (Blue) V (Note 1) Internal circuit Users circuit Notes: 1) The quick-connection sub cable does not have +V (brown) and V (blue). The power is supplied from the connector of the main cable. 2) 25 ma max., if five amplifiers, or more, are connected together. Symbols D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor FX-35P I/O circuit diagram Symbols D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor to 24 V DC ±1 % Wiring diagram Brown (Note) Black NPN output type Color code of quick-connection cable oad 12 to 24 V DC ±1 % Blue (Note) Note: The quick-connection sub cable does not have brown lead wire and blue lead wire. Terminal arrangement diagram Wiring diagram 1 +V 3 Output 2 V Brown (Note) + PNP output type Color code of quick-connection cable Black + 12 to 24 V DC ±1 % oad Blue (Note) Note: The quick-connection sub cable does not have brown lead wire and blue lead wire. Terminal arrangement diagram Wiring diagram 1 +V 3 Output 2 V Brown (Note) Black White NPN output type Blue (Note) Note: The quick-connection sub cable does not have brown lead wire and blue lead wire. Terminal arrangement diagram Wiring diagram 1 +V Color code of quick-connection cable oad oad 3 Output 1 4 Output 2 2 V Brown (Note) Black White + 12 to 24 V DC ±1 % PNP output type Blue (Note) Note: The quick-connection sub cable does not have brown lead wire and blue lead wire. Terminal arrangement diagram 1 +V Color code of quick-connection cable oad oad 3 Output 1 4 Output 2 2 V + 12 to 24 V DC ±1 %

19 195 Digital Sensor SERIES SENSING CHARACTERISTICS (TYPICA) The following sensing characteristics pertain to the red ED type.please contact our office for the sensing characteristics pertaining corresponding to types other than the red ED or to types not mentioned here. Thru-beam type Parallel deviation Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.) FT-A8 FT-WA8 Horizontal direction 4, U-G 3, , H-SP 1, l eft Center Right FT-NFM2 FT-NFM2S FT-NFM2S4 FT-SNFM U-G Thru-beam type H-SP l eft Center Right FD-B H-SP Reflective type White non-glossy paper l U-G eft Center Right Reflective type Sensing fields FD-NFM2 FD-NFM2S FD-NFM2S4 FD-SNFM2 FD-T H-SP Reflective type White non-glossy paper U-G l eft Center Right Vertical direction 4, , , , Thru-beam type U-G H-SP Down Center Up FT-P81X 1, l 8 mm.315 in approx. Thru-beam type U-G H-SP l eft Center Right FT-B8 2, , Thru-beam type U-G 1, H-SP l eft Center Right FT-FM2 FT-FM2S FT-FM2S4 FT-SFM2 FT-T8 1, H-SP l U-G Thru-beam type eft Center Right FT-W4 FT-WS4 Thru-beam type FT-W8 FT-WS8 Thru-beam type U-G H-SP l eft Center Right U-G H-SP 2 l eft Center Right Sensing characteristics are listed by model No. in alphabetical order. (However, models with the same sensing characteristics are listed together.) FD-FM H-SP Reflective type U-G White nonglossy paper l eft Center Right FD-P81X H-SP Reflective type White non-glossy paper l U-G eft Center Right FD-G H-SP Reflective type White non-glossy paper l U-G eft Center Right FD-W8 FD-WS8 FD-WT H-SP Reflective type White non-glossy paper l U-G eft Center Right FD-G6X H-SP FD-WG4 FD-WSG Reflective type White non-glossy paper l U-G eft Center Right H-SP Reflective type White non-glossy paper l U-G eft Center Right

20 Digital Sensor SERIES 196 PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. Mounting Connection Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The digital fiber sensor FX-31(P) has been modified since its production in June 24. The explanations below are about the modified product. How to mount the amplifier Fit the rear part of the mounting section of the amplifier on a 35 mm in width DIN rail. Press down the rear part of the mounting section of the unit on the 35 mm in width DIN rail and fit the front part of the mounting section to the 35 mm in width DIN rail. How to remove the amplifier Push the amplifier forward. ift up the front part of the amplifier to remove it. Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. installation 35 mm in width DIN rail Insert the fiber into the amplifier after attaching the attachment. Refer to the "Instruction Manual" included with the fiber for details. Push the fiber lock lever down. Slowly insert the fiber into the insertion lock lever slot until it stops. (Note 1) Push the fiber lock lever back up until it stops. Notes: 1) Note that if the fiber is not fully inserted, the sensing distance will decrease. Also note that the flexible fiber may bend during insertion. 2) In case of coaxial reflective type fibers (FD-G4, FD-FM2, etc.), mount the central fiber (single-core) to the emitter part and the peripheral fiber (multi-core) to the receiver. Note that sensing precision will deteriorate when done in reverse. Make sure that the power supply is off while connecting or disconnecting the quick-connection cable. Connection method Holding the connector of the quick-connection cable, align its projection with the groove at the top portion of the amplifier connector. Insert the connector till a click is felt. Groove Projection Quick-connection cable Disconnection method Pressing the projection at the top of the quick-connection cable, pull out the connector. Note: Take care that if the connector is pulled out without pressing the projection, the projection may break. Do not use a quick-connection cable whose projection has broken. Further, do not pull by holding the cable, as this can cause a cable-break. Cascading Projection Make sure that the power supply is off while adding or removing the amplifiers. Make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade. In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail. When the amplifiers move on the DIN rail depending on the attaching condition or the amplifiers are mounted close to each other in cascade, fit them between the optional end plates (MS-DIN-E) mounted at the two ends. Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.) When connecting more than two amplifiers in cascade, use the sub cable (CN-71-C / CN-72-C ) as the quick-connection cable for the second amplifier onwards. When connecting amplifiers not close to each other in parallel, be sure to mount the optional end plate (MS-DIN-E) at both sides of each amplifier or affix the communication window seal of the accessory amplifier protection seal (FX-MB1) to the communication windows. The settings other than the interference prevention function cannot be transmitted between FX-31(P) FX-31B/G/H(P), FX-35(P). Therefore, in case both models of amplifiers are mounted in cascade, be sure to mount identical models together. However, the interference prevention function is not incorporated in the FX-31(P)-HS. Take care when the sensors are mounted in cascade. If the FX-31(P) updated version unit or the FX-35(P) is mounted with the FX-31(P) previous version unit or the FX-31B/G/H(P) in cascade, place the FX-31(P) updated version units and the FX-35(P) units to the right side (seen from the connector side) of the previous version units. For details, refer to Cautions on sensor connection in cascade. For a difference between the updated version unit and the previous version unit, refer to A difference between the updated version unit and the previous version unit. The communication function of this product and that of the FX-31(P)-F / F7 is different. If these models are mounted in cascade, affix the accessory fiber amplifier protection seal (FX-MB1) included in the FX-31(P) and FX-35(P) to the communication windows of the amplifiers.

21 197 Digital Sensor SERIES PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. Cascading method Mount the amplifiers, one by one, on the 35 mm in width DIN rail. Slide the amplifiers next to each other, and connect the quickconnection cables. Mount the optional end plates (MS-DIN-E) at both the ends to hold the amplifiers between their flat sides. Tighten the screws to fix the end plates. Main unit Sub unit 35 mm in width DIN rail Sub cable (CN-71/72-C ) (Optional) Slide Main cable (CN-73/74-C ) (Optional) How to change the communication specification of Group B Change the communication specification of Group B according to the following procedures. Make sure to set the communication specification to (Group A communication specification) or (Optical Communication Stop). <Changing Procedure> Display [PRO4]. ong press the [Jog Switch] and [MODE key] at the same time. (Note 3) Dismantling oosen the screws of the end plates. Remove the end plates. Slide the amplifiers and remove them one by one. Cautions on sensor connection in cascade When the units in the group A and the group B shown in the table below are connected in cascade, connect them in cascade as <Figure A> shown below. <Figure A> <Figure B> Optical communications Optical communications are possible are impossible Group A Group B Group B Group A Group A Group B End plate (MS-DIN-E) (Optional) Slide FX-31(P): Previous version unit (Note 1), FX-31G(P)/B(P)/H(P), FX-41 (P), S-41(P) (Note 2) FX-31(P): Updated version unit (Note 1), FX-35(P) Notes: 1) For the difference between the updated version unit and the previous version unit, refer to A difference between the updated version unit and the previous version unit. 2) When S-41(P) is connected with the digital fiber amplifier in cascade, be sure to locate S-41(P) at the left-most position (when viewed from the connector side). When the units of the group A and the group B are connected in cascade as <Figure B> shown above, optical communications cannot be done. When the optical communications function is used, connect them as <Figure A> shown above. If the units cannot be placed as <Figure A>, the following measure 1 or 2 should be taken. 1 Affix the communication window seal of the accessory fiber amplifier protection seal (FX-MB1) to the communication window of the FX-31(P) updated version unit or FX-35(P). 2 If the measure 1 described above cannot be taken, change the optical communications spec. of the group B units. Group B's Communication Specification Notes: 3) Every time the [Jog Switch] and the [MODE key] is simultaneously long pressed, the display changes in this sequence:. When you release the [Jog Switch] and [MODE key], the communication specification will be set and PRO4 will be displayed. Notes: 4) When the communication specification is set to (Group A communication specification), make sure to tightly attach the products. Also make sure to take note of the following: There are instances when the optical communication function cannot be used due to the usage environment, etc. Do not perform batch channel loading or saving. Part description Operation indicator (Orange) (Note1) MODE indicator / RUN (Green) MODE indicator / TEACH (Yellow) MODE indicator / ADJ (Yellow) Group A's Communication Specification Stability indicator (Green)(Note2) MODE indicator / PRO (Yellow) Digital display (Red) MODE indicator / /D ON (Yellow) MODE indicator / TIMER (Yellow) Notes: 1) FX-35(P); Output 1 operation indicator (Orange) 2) FX-35(P); Output 2 operation indicator (Orange) Operation procedure Optical Communication Stop Jog switch MODE key When the power supply is switched on, communication self-check is carried out and normal condition is displayed [MODE indicator / RUN (green)] lights up and the digital display shows the incident light intensity. When the MODE key is pressed, the mode will change as shown in the following diagram. Power ON [Teaching] (P.198) [Threshold value fine adjust] (P.199) Communication self-check RUN TEACH ADJ Press MODE key Press MODE key Press MODE key Press MODE key Press MODE key Press MODE key PRO TIMER /D [PRO mode] (P.22) [Timer operation setting] (P.199) [Output operation setting] (P.199) When Jog switch is pressed, the setting is confirmed. When MODE key is pressed for 2 sec., or more, the sensor returns to the RUN mode. Cancellation is possible by pressing MODE key during setting.

22 Digital Sensor SERIES 198 PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. For FX-35(P) The FX-35(P) is equipped with two independent outputs, but the items that can be set in output 1 and output 2 respectively are only the following. The items other than those are common. 1 Threshold value 2 Output operation 3 Timer operation and Timer period 4 Sensing mode Teaching The threshold values can be set by 2-point teaching, limit teaching, full-auto teaching or window comparator mode (1-point, 2-point, 3-point teaching) [only for FX-35(P)], when the MODE indicator / TEACH (yellow) lights up. In case of 2-point teaching This is the method of setting the threshold value by teaching two levels, corresponding to the object present and object absent conditions. Normally, setting is done by this method. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-35(P), select either Output 1 or Output 2 beforehand, press jog switch in the object present condition. If the teaching is accepted, the read incident light intensity blinks in the digital display. Thru-beam type Beam blocked condition Reflective type Mark Background MODE indicator / TEACH (yellow) blinks. Press jog switch in the object absent condition. Thru-beam type Reflective type Mark Beam incident condition Background If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the midvalue between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. In case stable sensing is possible: is displayed. In case stable sensing is not possible: blinks. The threshold value is displayed. blinks in the digital display. (only FX-31B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. 2) In case a reflective-type fiber is used, maximum sensitivity will be set if the jog switch is pushed while in no work status in procedure and. In case of full auto-teaching Full auto-teaching is used when it is desired to set the threshold value without stopping the assembly line, with the object in the moving condition. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-35(P), select either Output 1 or Output 2 beforehand, press the jog switch continuously for.5 sec. or more with the object moving on the assembly line. (The incident light intensity is displayed during sampling.) is displayed on the digital display. Release the jog switch when the object has passed. If the teaching is accepted, the read incident light intensity blinks in the digital display and the threshold value is set at the midvalue between the incident light intensities in the object present and the object absent conditions. After this, the judgment on the stability of sensing is displayed. In case stable sensing is possible: is displayed. In case stable sensing is not possible: blinks. The threshold value is displayed. blinks in the digital display. (only FX-31B/G/H) The incident light intensity appears in the digital display and the setting is complete. Notes: 1) The threshold value s shift amount can be selected in PRO mode. Refer to the PRO Mode Operation for more details pertaining to setting instructions. (Increments of 5 % between 45 and 45 % for setting possible. % default.) 2) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable.

23 199 Digital Sensor SERIES PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. In case of limit teaching This is the method of setting the threshold value by teaching only the object absent condition (stable incident light condition). This is used for detection in the presence of a background body or for detection of small objects. Step Description Display Set the fiber within the sensing range. Press MODE key to light up MODE indicator / TEACH (yellow). For FX-35(P), select either Output 1 or Output 2 beforehand, press jog switch in the object absent condition. If the teaching is accepted, the read incident light intensity blinks in the display. Thru-beam type Reflective type Beam incident condition Background body MODE indicator / TEACH (yellow) blinks. Turn jog switch to the + side or side. If jog switch is turned to the + side, scrolls (twice) the display from right to left (Note 1), and the threshold level is shifted to a value approx. 15 % higher (lower sensitivity) than that set at. (Note 2) This is used in case of reflective type fibers. If jog switch is turned to the side, scrolls (twice) the display from left to right, and the threshold level is shifted to a value approx. 15 % lower (higher sensitivity) than that set at. (Note 2) This is used in case of thru-beam type fibers. High Threshold value ow 15 % 1 % 15 % OFF ON After this, the judgment on whether the setting shift amount can be shifted or not is displayed. In case shifting is possible: blinks. In case shifting is not possible: blinks. The threshold value is displayed. blinks in the digital display. (only FX-31B/G/H) The incident light intensity appears in the digital display and the setting is complete. ON OFF Turn to + side Turn to side Threshold value Incident light intensity with object absent Threshold value Notes: 1) Scrolling display is not available in FX-31B/G/H. 2) The approx. 15 % amount of shift is the initial value. The amount of shift can be changed in the PRO mode from approx. 5 to 8 % (5 % step). Refer to the PRO Mode Operation for more details pertaining to setting instructions. 3) Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable. Please download the instruction manual from our website for setting of threshold value when used in combination with liquid level sensing fiber FD-F8Y and with pipe-mountable liquid level sensing fiber FD-F4. Threshold value fine adjustment Step Description Display Press MODE key to light up MODE indicator / ADJ (yellow). For FX-35(P), select either Output 1 or Output 2 beforehand, in case the threshold value is to be increased (sensitivity to be reduced), turn the jog switch to the + side to increase the threshold value slowly. If the jog switch is turned continuously to the + side, the threshold value increases rapidly. In case the threshold value is to be decreased (sensitivity to be increased), turn the jog switch to the side to decrease the threshold value slowly. If the jog switch is turned continuously to the side, the threshold value decreases rapidly. When jog switch is pressed, the threshold value is confirmed. Output operation setting Step Description Display Press MODE key to light up MODE indicator / /D ON (yellow). For FX-35(P), select either Output 1 or Output 2 beforehand, if the jog switch is turn to the + or direction, the output operation setting will change. When jog switch is pressed, the threshold value is confirmed. Timer operation setting or Displays present setting ight state Dark state Displays selected setting The setting for whether the timer is used or not can be done when MODE indicator / TIMER (yellow) lights up. For FX-31B/G/H, the timer type can be set in PRO mode. Further, an OFF-delay (initial value) which is useful when the response of the connected device is slow, etc., an ON-delay which is useful to detect only objects taking a long time to travel, and ONE SHOT, which is useful when the input specifications of the connected device require a signal of a fixed width, are possible with the FX-31 (-HS). FX-35(P) is also equipped with ON-delay OFF-delay and ON-delay ONE SHOT timers. Refer to the PRO Mode Operation for the setting method of the OFF-delay, ON-delay and ONE SHOT timer intervals. For the wind comparator mode teaching in FX-35(P), refer to the separately prepared PRO Mode Operation.

24 Digital Sensor SERIES 2 PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Take care that short circuit of the load wrong wiring may burn or damage the product. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Make sure to use an isolation transformer for the DC power supply. If an autotransformer (single winding transformer) is used, this product or the power supply may get damaged. Make sure to use the optional quick-connection cable for the connection of the amplifier. Extension up to total 1 m ft is possible with.3 mm 2, or more, cable. (5-8 unit expansion: 5 m ft, 9-16 unit expansion: 2 m ft) However, in order to reduce noise, make the wiring as short as possible. Note that the residual voltage will increase when the cable is extended. Key-lock function If jog switch and MODE key are pressed for more than 2 sec. at the same time in RUN mode condition, the key operations are locked, and only the threshold value confirmation function or the adjust function (valid only when the adjust lock function is canceled) is valid. To cancel the lock function, press both the keys for more than 2 sec. once again. Note: 3 seconds or more for FX-31B/G/H(P). Others When the emission halt of the light emitting amount selection function is set from OFF to ON, the output may be unstable. Do not use the output control for.5 sec. after starting emission. Do not use during the initial transient time (.5 sec.) after the power supply is switched on. Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance. Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in contact with corrosive gas. Take care that the product does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. This sensor cannot be used in an environment containing inflammable or explosive gases. Never disassemble or modify the sensor. Function table for series Previous models New models Standard type High-function type High-speed type Standard type High-speed type High-function type FX-31(P) (Previous version unit) FX-32(P) FX-33(P) FX-31(P) (Updated version unit) FX-31(P)-HS FX-35(P) Four-chemical emitting element + APC circuit No No No Yes Yes Yes Four-chemical emitting element only Yes (Note) Yes Yes ight emitting amount selection function No No No Yes Yes Yes Reduced intensity mode (S-D) Yes (Note) Yes No Yes Yes 9,999 digit display No No No No No Yes Response time (Max. speed) 15 μs 3 μs 9 μs 65 μs 35 μs 65 μs Interference prevention function (Effective no. of units) Incorporated (4) Incorporated (8) Not incorporated () Incorporated (4) Not incorporated () Incorporated (16) Independent 2 outputs No No No No No Yes Alarm output function No No No No No Yes Error output function No No No No No Yes Differential sensing No No No No No Yes Window comparator mode No Yes No No No Yes Peripheral units that can be combined Bank selection unit FX-CH(-P) External input unit FX-CH2(-P) Upper communication unit SC-GU1-485 Yes Yes No No No No No No No Yes No Yes No No No Yes No Yes Note: Except FX-31B/G/H.

25 21 Digital Sensor SERIES PRECAUTIONS FOR PROPER Refer to General precautions, p.8~ for fiber precautions, and to the PRO mode operation guide on our website for details pertaining to operating instructions for the amplifier. A difference between the updated version unit and the previous version unit for FX-31(P) (Red ED type) The product has been modified as shown below since its production in June 24. Changes in appearance Top view Side view Before change Name plate Display Uses special parts * NAVI is printed only on the both sides Top view Side view After change Added to name plate Change in shape of jog switch * NAVI is printed only on a side Checking minor changes between previous and updated models can be done by checking whether the printing is on both sides or only one side. Upgraded functions 1. Response times added An ultra high-speed mode (H-SP) has been added to the existing 4 response time modes [high-speed (ST), reduced intensity (S-D), standard () and long range (ONG)]. This is changed using in 4 steps Before change 15 μs (ST) 25 μs (S-D) 25 μs () 2 ms (ONG) 5 steps After change 65 μs (added) (H-SP) 15 μs (ST) 25 μs (S-D) 25 μs () 2 ms (ONG) Changes in operation 1. Timer selection method Previous version unit: Timer type was changed using PRO1 mode. The TIMER setting in NAVI mode could only be turned on or off. After change: The type of timer can be changed using the TIMER function in NAVI mode. 2. Checking threshold value in RUN mode The threshold values can be checked by turning the jog switch. Display changes 1. Checking blinking of sensitivity surplus The stable surplus display method after teaching has been changed. Previous version unit: Sensitivity surplus is indicated by the number of blinks of the stability indicator. After change Digital display only 2. Initial direct code value changed The factory default settings for the direct codes have been changed. Previous version unit After change 4 * The default setting for the timer period is 1 ms, and the direct code for 1 ms is 4, so this has been changed. Internal circuit changes 1. Addition of an APC circuit A four-chemical emitting element which provides stable sensing over long periods has been added, as well as an APC (Auto Power Control) circuit that improves stability during short periods. Cautions on sensor connection in cascade When connecting the previous version unit (including FX-31B/G/H) and updated version unit to be used in a cascade, refer to Cautions on sensor connection in cascade. 2. Extension of timer period The setting range for the timer period was previously 5 ms, but this has been extended to a new range of 9,999 ms. 3. ight emitting amount selection function The light emitting amount can be changed to one of 4 levels (5 levels when emission halt is included). 4. Backup, copy lock and key lock functions added Backup: This selects whether or not threshold values set by teaching are written to (stored in) an EEPROM. Copy lock: This selects whether copy function and data bank function communication are possible or not. Key lock: This disables input using switches to prevent accidental changing of settings.

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance 177 PHOTO MICRO PHOTO AREA LIGHT CURTAINS PRESSURE / FLOW INDUCTIVE PROXIMITY PARTICULAR USE SENSOR SIMPLE UNITS MEASUREMENT STATIC CONTROL DEVICES ENDOSCOPE MARKERS PLC / TERMINALS HUMAN INTERFACES ENERGY

More information

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance

Digital Fiber Sensor FX-300 SERIES. Constant advances achieving significant improvement of sensing performance 19 Digital SERIES General terms and conditions... P.1 Related Information FX-CH2 / SC-GU1-485...P.199 / P.201 ~ Korea s S-mark... P.104~ Sensor selection guide P.11~ / P.61~ Glossary of terms / General

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) All seven laser types provide ample long distance, for the Diffuse Reflective Model 1.000 mm and for Retroreflective

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. SERIES Color Detection Sensor Reliable and Precise Color Discrimination Marked Conforming to EMC Directive Red, Green and Blue LEDs incorporates red, green and blue LEDs as its beam sources, which promise

More information

AUTOMATIC SETTING TYPE OPTICAL FIBER PHOTOELECTRIC SENSORS. Long Sensing Range. The standard M4 fiber offers the sensing range of 600mm inch.

AUTOMATIC SETTING TYPE OPTICAL FIBER PHOTOELECTRIC SENSORS. Long Sensing Range. The standard M4 fiber offers the sensing range of 600mm inch. AUTOMATIC TING TYPE OPTICA FIBER PHOTOEECTRIC SENSORS UZF Series COMPACT SIZE WITH ADVANCED SENSING TECHNOOGY Thickness : mm inch Just mm inch thick. Even a number of UZF amplifiers save space. Only mm

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button FZ- SERIES Color Detection Sensor N output type available Timer Reliable and precise color discrimination FX-30 Conforming to EMC Directive UL Recognition FZ- FX-A FX-3 FX-CH Color Detection Analog Output

More information

E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection.

E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection. New Product Digital Fiber Sensors E3X-DA-S An Extensive of Functions to Support the World's Highest Level of Stable Detection. "GIGA RAY" Giga Power Lighting Element to create a wide variety of value.

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features Air Particle Sensor Smallest Air Particle Sensor in the Industry for In-line Measurement Suitable for continuous measurement. With Realtime Clean Air Monitor. Be sure to read Safety Precautions on page

More information

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application E3X-DA-S Digital Fiber Sensors Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application Evolution and Perfection The next-generation platform for a wide range of sensing

More information

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating UV Power Monitor Monitor the Output of a UV Light Source through an Optical Fiber Cable Head Unit withstands temperatures of up to 300 C. Easy-to-read digital display of measurement values. Harmful UV

More information

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use Digital Fiber Amplifier Digital Fiber Amplifier Provides High Performance and Ease of Use First amplifier to offer three user-selectable displays: digital level, percentage and analog display Flashing

More information

F70series. Variation. Excellent detection performance

F70series. Variation. Excellent detection performance F70series Digital display Fiber optic sensors Digital indication of sensing information arious advanced functions provide for optimum use of the sensor Unparalleled high resolution allows highly accurate

More information

E3C-LDA. Phone: Fax: Web: - Operating Procedures: Photoelectric Sensors

E3C-LDA. Phone: Fax: Web:  -   Operating Procedures: Photoelectric Sensors E3C-LDA Operating Procedures: Photoelectric Sensors 1 Setting the Operation Mode The operation mode is set with the. Operation mode Operation Light ON L-ON Dark ON D-ON L (Factory-set) D *Advanced Twin-output

More information

Type F70AB F70ABPN. Digital display. Simple operation featured

Type F70AB F70ABPN. Digital display. Simple operation featured F70Aseries Digital display Fiber optic sensors Digital indication of sensing information Simple operation for setting functions Direct reading of stablility level is available along with received light

More information

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application E3X-DA-S Digital Fiber Sensors Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application Evolution and Perfection The next-generation platform for a wide range of sensing

More information

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information

More information

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications Photoelectric proximity switches Photoelectric reflex switches W 90 L: Application-based Laser Technology, the optimum solution for demanding applications Do your customers require reliable sensors suitable

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No. 6 HPX-T Series Au-tuning Fiber Optic Phoelectric Control Specifications FEATURES Built-in Au-tuning Aumatically Adjusts Scanning Characteristics. Adjustment Steps, Results and Scanning Conditions Digitally

More information

W 9-2: A Versatile, Complete and Compact Series

W 9-2: A Versatile, Complete and Compact Series suitable sensor can be selected from the W 9- series. Overview of the sensors: WT 9-, with adjustable background suppression, max. scanning distance 0 mm, WT 9-, energetic, max. scanning distance 0 mm,

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

True Color Sensor with Analog and Digital Outputs

True Color Sensor with Analog and Digital Outputs SMARTEYE ColorWise TM 2 Specialty Application Photoelectric Sensors True Color Sensor with Analog and Digital Outputs 2-79 Specialty Application Photoelectric Sensors 2 SMARTEYE ColorWise TM The SMARTEYE

More information

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission Compact Sensors - S6 S6 The most complete universal sensor in a compact x housing Sensors with red, infrared or LASER emission from 3 cm to m Polarized retroreflective up to 0 m Multivoltage 4-40Vac/4-60Vdc

More information

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx laser / / 2010 Operating instructions Through-beam sensor OJ5xx laser 70480 / 00 05 / 200 Contents Preliminary note. Symbols used 2 Safety instructions Functions and features 4 4 Installation 4 5 Electrical connection5

More information

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type. INSTRUCTI MANUAL Sensor High-performance Digital Display DP-1 Series Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

Main Display (Red) Displays the incident light level or the function name.

Main Display (Red) Displays the incident light level or the function name. E3X-DA-S/E3X-MDA Operation Reference Main Display (Red) Displays the incident light level or the function name. Sub-Display (Green) Displays the threshold and function settings. Operation Keys Used to

More information

No Need to Select. Intensity Detection (Previous Type)

No Need to Select. Intensity Detection (Previous Type) Color Sensing Digital Fiber Sensor CSM DS_E_5_4 Easy and Reliable he Fiber Sensor hat Sees in Color High-power white LED and multi-rgb processing eliminate the need to select light source (wavelength)

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

SA1J-F: Full Color Fiber Optic Sensors

SA1J-F: Full Color Fiber Optic Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain ice: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com This new line of full color sensors offers

More information

Pre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8

Pre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8 Smart Fiber Amplifier Units E3NX-FA CSM_E3NX-FA_DS_E_2_1 The Advanced Fiber Amplifier Units That Handles On-site Needs Improved basic performance with 1.5 times the sensing distance and approx. 1/10th

More information

DF-G3 Long Range Expert Dual Display Fiber Amplifier

DF-G3 Long Range Expert Dual Display Fiber Amplifier DF-G3 Long Range Expert Dual Display Fiber Amplifier Quick Start Guide Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; single or dual independent output

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

SENSORS S60. Compact Sensors - S60. Extended range of standard One for All photoelectric compact sensors

SENSORS S60. Compact Sensors - S60. Extended range of standard One for All photoelectric compact sensors S60 Extended range of standard One for ll photoelectric compact sensors Complete range of optic functions, basic, advanced and laser class 1 Models with coaxial optics for polarized retroreflective, contrast

More information

Pre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8

Pre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M. Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8 Smart Fiber Amplifier Units E3NX-FA CSM_E3NX-FA_DS_E_2_1 The Advanced Fiber Amplifier Units That Handles On-site Needs Improved basic performance with 1.5 times the sensing distance and approx. 1/10th

More information

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description Component Systems Technical Description Features Applications The mini optical series of sensors are among smallest sensors in the world. Mini optical sensors require almost no space and with their low

More information

DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual

DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual DF-G3 Long Range Expert Dual Display Fiber Amplifier Instruction Manual Original Instructions 187436 Rev. F 21 April 2017 Banner Engineering Corp. All rights reserved 187436 Contents 1 Product Description...3

More information

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Warner Photoscanner MCS-500 Series LED Photoelectric Control Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors Mechanical Electrical Optical Cat No. Strobing Models COS Models Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors Polarized Retroreflective Retroreflective Standard Diffuse

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

Detect Color and Shape for various inspection

Detect Color and Shape for various inspection CVS2-RA SERIES MVS Series APPLICATI CVSE1-RA CVS1-RA CVS2-RA CVS3-RA CVS-R OPTIS Wide range line-up CVS2-N20-RA Standard type CVS2-N10-RA Long range type CVS2-N0-RA Macro view type CVS2-N21-RA Narrow view

More information

2 outputs + 1 input. Connector for Sensor Communications Unit. Sensing method Appearance Sensing direction Size Model

2 outputs + 1 input. Connector for Sensor Communications Unit. Sensing method Appearance Sensing direction Size Model Color Fiber Amplifier Unit E3NX-CA Smart Fiber Amplifier Units with White LEDs. High Color Discrimination Capability with the Same Easy Operation as Previous Fiber Amplifier Units. Existing General-purpose

More information

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type F71series Manual setting Fiber optic sensors Adjacent installation of up to 8 units - Proprietary Anti Interference feature is used - High-accuracy-8-turn sensitivity adjustment - Position indicator is

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Safety Light Curtain Orion1 Extended

Safety Light Curtain Orion1 Extended Safety Light Curtain is an easy to use light curtain with compact dimensions. It has two resolutions for detection of fingers and hands, and comes with advanced features like cascading, muting and blanking.

More information

SPACESCAN SERIES SS 02

SPACESCAN SERIES SS 02 Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc

More information

SPECIFICATION. Spec No : VSS-1402-CS603B

SPECIFICATION. Spec No : VSS-1402-CS603B SPECIFICATION Spec No : VSS-1402-CS603B 1. INTRODUCTION 1.1. General This specification covers the design requirements and characteristics required of fiber optic splice closures to be used on fiber optic

More information

Operating instructions Through-beam sensor. OJ51xx / / 2004

Operating instructions Through-beam sensor. OJ51xx / / 2004 Operating instructions Through-beam sensor OJ5xx UK 7098 / 0 07 / 004 Contents Function and features... Installation... Installation of the supplied mounting fixture...4 Electrical connection...4 Setting

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Amplifier for fiber optics. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing Amplifier for fiber optics Dimensioned drawing up to 525mm up to 120mm 10-30 V DC 3-digit display for indicating and setting the switching threshold NEW: AutoSet function for easy sensor adjustment Menu

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

D12 Expert Series TEACH-Mode Fiber Optic Sensors

D12 Expert Series TEACH-Mode Fiber Optic Sensors TEACH-Mode Fiber Optic Sensors One-button programmable sensors for use with glass or plastic fibers D Expert Features Fiber optic sensors for DIN rail mounting; 0 to 30V dc operation Visible red (680 nm)

More information

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual DF-G2 High Speed Expert Dual Display Small Object Counter Instruction Manual Original Instructions 178236 Rev. E 9 September 2015 178236 Contents 1 Product Description... 3 1.1 Models...3 1.2 Overview...

More information

Q3X Laser Contrast Sensor

Q3X Laser Contrast Sensor Quick Start Guide Laser Expert diffuse sensor with bipolar ( PNP & NPN) output. Patent pending. This guide is designed to help you set up and install the Q3X Sensor. For complete information on programming,

More information

Installation Guide VL-MV10. Model No.

Installation Guide VL-MV10. Model No. Installation Guide Model Name Model No. Main Monitor Station VL-MV0 R Main monitor station is described as "main monitor" in this guide. R In this guide, the suffix of each model number (e.g., the "EX"

More information

W100L: Laser Sensor in Mini- Format

W100L: Laser Sensor in Mini- Format Product group W00 Laser Photoelectric proximity switch energ. Photoelectric reflex switch W00L: Laser Sensor in ini- Format Through-beam photoelectric switch Where applications demand it, the sensor can

More information

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height All non- products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website search at www.hirose-connectors.com, or contact your Hirose sales representative.

More information

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Quick Start Guide Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; analog current

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance NEW Safety Light Curtain MS4800 Series Strong, Durable Body and Long, 20-m Sensing Distance A Powerful Safety Light Curtain with Durable, Impact-resistant Body and Long, 20-m Sensing Distance Has Arrived.

More information

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

1 Inductive proximity switches. 5 Connecting cables. Highlights: New: Highlights: - All-metal housings - Miniature sizes - Long operating distances - Extreme environmental conditions - Analog outputs New: - All-metal devices for food industry and sea-water applications -

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled E 15 W CE CPS ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5 SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled CE CPS 12/15 W ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

Q3X Laser Contrast Sensor

Q3X Laser Contrast Sensor Quick Start Guide Laser Expert diffuse sensor with bipolar ( PNP & NPN) output. Patent pending. This guide is designed to help you set up and install the Q3X Sensor. For complete information on prograing,

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Amplifier for fiber optics. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing Amplifier for fiber optics Dimensioned drawing with cable en 01-2012/09 50118006 up to 1050mm up to 270mm with M8 connector 10-30 V DC We reserve the right to make changes DS_LV463_en_50118006.fm wo, large,

More information

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ Transmission of process value and parametrization via IO-link Cable with male end, PVC, M8 x 1, 4-pin, 150 mm Protection class IP67 LED, all-round visible Coaxial optics Sensitivity adjusted via teach

More information

Q3X Laser Contrast Sensor

Q3X Laser Contrast Sensor Quick Start Guide Laser Expert diffuse sensor with bipolar ( PNP & NPN) output. Patent pending. This guide is designed to help you set up and install the Q3X Sensor. For complete information on programming,

More information

WF next: Fork sensors for a wide range of applications

WF next: Fork sensors for a wide range of applications WF next: Fork sensors for a wide range of applications D ATA S H E E T Fork sensors TThe detection of labels, marks and double sheets, as well as holes and edges are typical applications for the new WF

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication

More information

FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS AND SERIOUS CALLBACKS.

FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS AND SERIOUS CALLBACKS. Installation and Operation Manual CEDES GridScan GRS Safety light curtain for industrial doors English EN 13849-1 Only GRS 7xx: Only GRS 7xx: EN 12978 IEC 61496-2 IMPORTANT NOTE FOLLOW THE INSTRUCTIONS

More information

LED Type Optical Displacement Sensor

LED Type Optical Displacement Sensor LED Type Optical Displacement Sensor User s Manual Sensor head LH-50 series General purpose controller LH-CL6, LH-CL6P First Edition Contents Contents 1. INTRODUCTION...1 2. CHECKING PACKED ITEMS...3 CHAPTER

More information

E3X-DAC-S Digital Fiber Sensor

E3X-DAC-S Digital Fiber Sensor Digital Fiber Sensor Easy and Reliable Color Detection» Highly resistant to target vibration» Fast 60 μ s response time» Wide range of sensor head options RGB Color Sensing Technology Precise Color Detection

More information

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Instruction Manual Original Instructions 190341 Rev. E 21 April 2017 Banner Engineering Corp. All rights reserved 190341 Contents

More information

V 180 Series Photoelectric Switches

V 180 Series Photoelectric Switches D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal

More information

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

More Precision. confocaldt // Confocal chromatic measuring system

More Precision. confocaldt // Confocal chromatic measuring system More Precision confocaldt // Confocal chromatic measuring system Confocal chromatic sensors for displacement and thickness confocaldt IFS206 / IFS207 IFS206-/VAC(001) IFS206-/VAC(001) IFS206/90-/VAC(001)

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

Luminaire installation box Surface-mounted box Ceiling installation box

Luminaire installation box Surface-mounted box Ceiling installation box -Smart PTM Ambient light sensor and motion detector for constant lighting control uminaire installation box Surface-mounted box Ceiling installation box Overview: -SMART PTM i is an ambient light sensor,

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Models available for a wide variety of applications at manufacturing sites. 20mm 10mm

Models available for a wide variety of applications at manufacturing sites. 20mm 10mm Digital Fiber Amplifier Unit E3X-DA-S/MDA CSM_E3X-DA-S_MDA_DS_E_15_2 Advanced Fiber Amplifier Units Features a Power Tuning function that optimizes light reception at the press of a button. APC circuits

More information

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement

I-SERIES. A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement NEW CMOS Multi-Function Analogue Laser Sensor IL Series A wide lineup of measurement ranges capable of solving many applications, from part differentiation to high precision measurement Seam detection

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

60 ± 10 mm 4. (See Note.) PNP E3MC-X ± 4mm 4 NPN E3MC-MX11. (See Note.) PNP. mended. fiber. 4 NPN E3MC-MY11 E32-T16

60 ± 10 mm 4. (See Note.) PNP E3MC-X ± 4mm 4 NPN E3MC-MX11. (See Note.) PNP. mended. fiber. 4 NPN E3MC-MY11 E32-T16 R RGB Color Sensor RGB Color Sensor Detects Subtle Color Differences The Most Advanced Color Sensor In the Industry H LED light source insures ease of operation and long life H No separate light source